11
ANSI/ASHRAE /USGBC/IES/ Standard 189.1-2011 AND ITS REQUIREMENTS COMPARED TO LEED V 3 Presented by: Rachael Green Huitt-Zollars; USGBC North Texas Chapter [email protected] 214-871-3311 x 10127

ANSI/ASHRAE /USGBC/IES/ Standard 189.1-2011 AND ITS REQUIREMENTS COMPARED TO LEED V 3

  • Upload
    tab

  • View
    76

  • Download
    0

Embed Size (px)

DESCRIPTION

ANSI/ASHRAE /USGBC/IES/ Standard 189.1-2011 AND ITS REQUIREMENTS COMPARED TO LEED V 3. Presented by: Rachael Green Huitt-Zollars; USGBC North Texas Chapter [email protected] 214-871-3311 x 10127. Compliance Paths. Prerequisites (Mandatory) + Credits (Optional) - PowerPoint PPT Presentation

Citation preview

Page 1: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ANSI/ASHRAE /USGBC/IES/Standard 189.1-2011 AND ITS REQUIREMENTS COMPARED TO LEED V 3Presented by: Rachael GreenHuitt-Zollars; USGBC North Texas [email protected] x 10127

Page 2: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

Compliance Paths

Prerequisites (Mandatory)+ Credits (Optional)________________________Minimum 40 points

Category (SS, WE, EA, MR, IEQ, ID, RP)

MandatorySection x.3 +

Prescriptive PathSection x.4

Performance PathSection x.5

Page 3: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

CHAPTER 5 SITE SUSTAINABILITY

SECTION 5.3.4 PLANTS

NO REQUIREMENTS FOR INVASIVE SPECIES DISPOSAL.

5.3.4.1 Invasive PlantsInvasive plants shall be removed from the building project site and destroyed or disposed of in a land fill.

Page 4: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

Section 9.3.1.1 Diversion - Minimum of 50% Diverted

Section 9.3.1.2 Total Waste - Limitations and required prior to CO

CHAPTER 9 – THE BUILDINGS IMPACT ON THE ATMOSPHERE, MATERIALS AND RESOURCES SECTION 9.3.1 CONSTRUCTION WASTE MANAGEMENT

1 point for 50%2 points for 75%1 point for ID at 95%1 point for RP in some locations if you achieve 50%

MATERIALS AND RESOURCES

CREDIT 2 – CONSTRUCTION WASTE MANAGEMENT

Page 5: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

Page 6: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

Page 7: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

Section 9.3.4.1 Recyclables – dedicated areas for paper, corrugated cardboard, glass, plastics and metalsSection 9.3.4.2 Reusable goods – with residential spaces dedicated area for discarded but clean items in good condition for charitable organizations or others to arrange pickupSection 9.3.4.3 Fluorescent and HID Lamps and Ballasts – dedicated area

CHAPTER 9 – THE BUILDINGS IMPACT ON THE ATMOSPHERE, MATERIALS AND RESOURCES

SECTION 9.3.4 STORAGE AND COLLECTION OF RECYCLABLES AND DISCARDED GOODS

Dedicated area for paper, corrugated cardboard, glass, plastics and metals

MATERIALS AND RESOURCES

PREREQUISITE 1STORAGE AND COLLECTION OF RECYCLABLES

Page 8: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

Page 9: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

No-Idling of Construction Vehicles:Vehicle staging areas shall be established for waiting to load or unload materials. These staging areas shall be located 100 ft (30m) from any outdoor air intakes, operable openings, and hospitals, schools, residences, hotels, daycare facilities, elderly housing and convalescent facilitates.

CHAPTER 10 CONSTRUCTION AND PLANS FOR OPERATION

SECTION 10.3.1.6 CONSTRUCTION ACTIVITY POLLUTION PREVENTION

NO REQUIREMENTS.

Page 10: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

ASHRAE Standard 189.1-2011 LEED v3

What needs to be recycled, where can it be recycled, how can it be recycled, costs associated with recycling

CHAPTER 10 CONSTRUCTION AND PLANS FOR OPERATION

10.3.2.3 SERVICE LIFE PLAN

CRADLE ToCRADLE

NO REQUIREMENTS.

Page 11: ANSI/ASHRAE /USGBC/IES/ Standard  189.1-2011  AND ITS REQUIREMENTS COMPARED TO  LEED V 3

How does it impact you? Recyclers: Value added service

Municipalities: Knowledge of what requirements are needed for building code/compliance

Waste industry: Identify future partners and what synergies there are. Think outside the box.

Identify and think about what are you asking, where and what is allowed, where is it going and end of life disposal.

Landfill: Clearly identify and educate everyone on what you do and don’t want and why or why not.

ASHRAE Standard 189.1-2011 vs. LEED v3