PLANT AREA : BOILEREQUIPMENT NAME : APH THRUST BEARING 1BSAMPLING DATE : 31/10/13REPORT DATE : 19/11/13 MACHINE CONDITION :
Machine Condition ReccomendationThe machine condition is normal . The debris examination showed bearing debris in moderate quantity as a sign of fatigue . Offline filtration suggested for checking wear rate .
Ferrous Wear Ferrous Wear Rating Non-Ferrous Wear Non-Ferrous Wear RatingParticles Particles
FERROGRAPHY
PLANT AREA : BOILEREQUIPMENT NAME : APH THRUST BEARING 1BSAMPLING DATE : 31/10/13REPORT DATE : 19/11/13 MACHINE CONDITION :
Analytical Ferrography - Detailed Analysis Of Wear Regimes Evident in Components
The ferrous density test showed a result of 33 ppm . The acceptable limit is 0 - 40 ppm .The normal rubbing wear particle studied was