APPENDIX C – ENERGY MODELING ANALYSIS AND RESULTS

Page 2: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

ARCHETYPE BUILDING INDEX

Introduction ................................................................................................................................................... C.i

1.0 Large Institutional Archetype Summary ............................................................................................... C.1

2.0 Low-Mid Rise MURB Archetype Summary ........................................................................................... C.6

3.0 High Rise MURB Archetype Summary ................................................................................................ C.10

4.0 Secondary School Archetype Summary ............................................................................................. C.17

5.0 Rec Centre Archetype Summary ......................................................................................................... C.22

6.0 Commercial Office Archetype Summary ............................................................................................. C.27

7.0 Hotel Archetype Summary ................................................................................................................... C.35

8.0 Non-Food Retail Archetype Summary................................................................................................. C.40

BUILDING ENVELOPE THERMAL BRIDGING GUIDEAppendix C ­ Energy Modeling Analysis and Results

Page 3: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.i

INTRODUCTION

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 4: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.ii

Introduction The energy analysis undertaken for this study is focused on generally quantifying the impact of the opaque envelope on whole building energy use for different major building types (archetypes). The energy results shown below are for illustrative purposes to give an approximate idea of the scale of the energy impact resulting from the opaque building envelope. The results should not replace project specific energy models for design decision making, but may be used as guidance to inform early design.

Archetypes The archetypes are rectangular buildings with size, number of stories and aspect ratios approximated based on experience with similar projects. Although buildings come in many different sizes, shapes and orientations, any geometry selected would be arbitrary; thus standard rectangular shapes were chosen.

Each archetype also uses mechanical and lighting systems that reflect standard practice for a large portion of the BC market. Mechanical and electrical systems can vary significantly between similar projects, however, one representative system was chosen for illustrative purposes. Higher performing mechanical systems may show less impact from the building envelope, while higher performing lighting systems may show more impact due to reduction in heat gain. However, the general trend and slope of the curves shown below are expected to be consistent for most buildings, though the absolute values may vary significantly depending on design. The energy model input details for each archetype are summarized below, with each input followed by graphs of electricity and gas energy use over varying R-values.

Energy Graphs The graphs below represent both annual electricity and gas energy usage over a wide range of R-values for each archetype, at two different glazing ratios, and for 3 different BC climates. The graphs were developed to quantify the difference in electricity and gas energy related to differences in the opaque envelope related to the impact of thermal bridging through interface details. Specific scenarios and results are discussed in detail in Part 2.

Energy Use Intensity Some readers may be interested in the overall energy results of the archetype buildings. A summary of the energy use intensity, in ekWh/m2, is shown in the Table below. The table considers the results for all archetype buildings, but only at one window to wall ratio, one R-value (R15) and one climate (Vancouver, BC).

Building Archetype

(Vancouver Climate)

Window-

to-Wall

Ratio (%)

Gas Use

Intensity

(kWh/m2)

Electricity Use

Intensity

(kWh/m2)

Total Energy

Use Intensity

(kWh/m2)

Institutional 30 250 178 427

Low Mid Rise MURB 30 126 60 186

High Rise MURB 40 126 60 186

Secondary School 20 80 69 148

Rec Centre 30 220 136 356

Commercial Office 40 36 107 143

Hotel 40 152 73 225

Non-Food Retail 30 83 88 171

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 5: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.iii

THERMAL MASS Most energy models deal with thermal mass through the use of conduction transfer functions. These functions are determined based on the materials of the assembly modeled, and tell the model how to distribute, over time, the heat losses and gains through the walls and roofs that are calculated at each time step. The calculation is independent of the U-value but impacts energy use through the distribution of heat losses and heat gains over time, dependent on the material properties modeled. Figures C0.1 and C0.2 respectively show the response factor and cumulative heat flow for low and high mass walls for a concrete high rise MURB with electric baseboard heating.

Figure C0.1: Response factor for mass walls

Figure C0.2: Cumulative heat flow for mass walls

Figures C0.3 through C0.8 below show the difference in energy use between high (concrete walls) and low (steel stud walls) thermal mass systems. At the lowest R-value, R2.5, there is as much as 3-5% heating energy savings for mass walls over steel stud walls for the high rise MURB archetype, depending on climate zone. However, over the range of R-values, the average difference in heating energy is 1% or less. The figures also show that a slightly lower R-value in mass walls, about R0.5 to R1.5 lower, yields the same energy use as lightweight walls. However, ASHRAE 90.1-2010 prescribes mass walls at R-values lower than steel stud walls by about R3, R1.5, and R10 for BC climate zones 5, 6, and 7, respectively. As such, the reduction in R-value for mass walls in ASHRAE 90.1 may not be fully warranted for BC climate zones. However, this point is somewhat moot since the change in absolute energy use at the higher prescribed code R-values is not significant.

0

0.005

0.01

0.015

0.02

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50

Hours

Low Mass

High Mass Interior Insulation

High Mass Exterior Insulation

00.05

0.10.15

0.20.25

0.30.35

0.4

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50

He

at F

low

(W

/m2 K

)

Hours

Low Mass

High Mass Interior Insulation

High Mass Exterior Insulation

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 6: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.iv

THERMAL MASS ANALYSIS ANNUAL ENERGY USE

Figure C0.3: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C0.4: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

60

70

80

90

100

110

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR, Steel Stud

40% WWR, Concrete Mass

150

152

154

156

158

160

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR, Steel Stud

40% WWR, Concrete Mass

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 7: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.v

THERMAL MASS ANALYSIS ANNUAL ENERGY USE

Figure C0.5: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C0.6: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

50

60

70

80

90

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR, Steel Stud

40% WWR, Concrete Mass

126

128

130

132

134

136

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR, Steel Stud

40% WWR, Concrete Mass

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 8: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.vi

THERMAL MASS ANALYSIS ANNUAL ENERGY USE

Figure C0.7: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C0.8: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

50

60

70

80

90

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR, Steel Stud

40% WWR, Concrete Mass

122

124

126

128

130

132

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR, Steel Stud

40% WWR, Concrete Mass

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 9: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.1

1.0 LARGE INSTITUTIONAL ARCHETYPE SUMMARY

Archetype Symmary Values Units / Notes

Gross Floor Area (GFA) 240,000 (22,297) ft2 (m2)

Number of Floors 6

Wall Height 15 (4.57) ft (m)

Window:Wall Ratio (WWR) 30% / 50%

Length:Width Ratio 4:1

Wall:Roof Ratio 2.25

Lighting Power Density (LPD) 1.2 (13) W/ft2 (W/m2)

Plug Power Density (PPD) 1 (10) W/ft2 (W/m2)

General System Information Boiler/Chiller/CT Plant, Constant Volume, CSA

Rates

Performance Details As per below According to standard practice

Zoning 15 5/floor, multiplier for middle floors

Building Envelope Components

Roof (insulated entirely above deck) 20.8 (3.66) R-value, h.ft2.F/BTU (m2.K/W)

Wall 23.7 (4.17) R-value Curve, h.ft2.F/BTU (m2.K/W)

Slab-on-grade (unheated) 0.159 (0.9) F-factor, BTU/h.ft.F (m.K/W)

Glazing (Double-pane) 0.387 (2.2) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Internal Loads

Occupancy 5 (20) person/100 ft2 (m2/person)

Lighting 1.2 (13) W/ft2 (W/m2)

Receptacle 1 (10) W/ft2 (W/m2)

Domestic Hot Water Peak 307 (90) BTUh/person (W/person)

Air Infiltration 0.05 (0.25) cfm/ft2 (L/s/m2) external surface area

Ventilation Rates

Air Changes Per Hour 2 Healthcare Estimate

Schedules

HVAC, Plug Loads, Lighting, Occupancy, Domestic

Hot Water

Health ASHRAE 90.1 - User's Manual, Table G-F

Zone Level Equipment

Total Supply Airflow Minimum at 6 ACH, peak autosized

Heating Equipment

Equipment Type Hot Water Reheat Coil

Controls

Heating Design Supply Air Temperature 20 (11.1) Above Space Temperature, F (°C)

Building Level Equipment

System Type VAV

Fan Control VFD

Fan Efficiency 65 %

Motor Efficiency 90 %

Total Fan Static Pressure 5 (1250) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil

Cooling Equipment

Equipment Type Chilled Water Coil

Controls

Heating Supply Air Temperature 50 (10) F (°C)

Cooling Supply Air Temperature Min 55, Max 64.4 (Min 12.8, Max 18) Reset for Warmest Zone, F (°C)

Outdoor Air Economizer 75 (24) Fixed Dry Bulb, Maximum Temperature, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 10: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.2

Plant Level Equipment

Heating Equipment

Equipment Type Gas Boiler

Efficiency 80 %

Design Water Outlet Temperature 177.8 (81) F (°C)

Hot Water Pump

Pump Control VFD

Pump Configuration Primary Only

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

Cooling Equipment

Equipment Type Electric Chiller

Efficiency 5 COP

Condenser Type Water Cooled

Chiller Flow Control Variable

Leaving Chilled Water Temperature 44 (6.67) F (°C)

Entering Condenser Fluid Temperature 85 (29.4) F (°C)

Chilled Water Pump

Pump Control VFD

Pump Configuration Primary and Secondary

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

Heat Rejection Equipment

Equipment Type Cooling Tower

Design Inlet Air Wet-Bulb Temperature 78 (25.6) F (°C)

Design Approach Temperature 7 (3.9) Difference, F (°C)

Design Range Temperature 10 (5.6) Difference, F (°C)

Condenser Pump

Pump Control Constant Speed

Pump Configuration Primary Only

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

SHW Equipment

System Type and Fuel Gas

Efficiency 80 %

Peak Demand 307 (90) BTUh/person (W/person)

Controls

Hot Water Design Exit Temperature 180 (82) F (°C)

Hot Water Loop Design Temperature Difference 20 (11.1) F (°C)

Chilled Water Design Exit Temperature 45 (7.22) F (°C)

Chilled Water Loop Design Temperature Difference 44 (6.67) F (°C)

Condenser Water Design Exit Temperature 85 (29.4) F (°C)

Condenser Loop Design Temperature Difference 42 (5.6) F (°C)

Hot Water Loop Temperature Min 150, Max 180 (Min 66, Max 82) Outdoor Air Reset, F (°C)

Chilled Water Loop Temperature Min 45, Max 54 (Min 7, Max 12) Outdoor Air Reset, F (°C)

Condenser Water Loop Temperature Min 70, Max 84 (Min 21, Max 29) Follow Outdoor Air, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 11: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.3

LARGE INSTITUTIONAL ANNUAL ENERGY USE

Figure C1.1: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C1.2: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

158

163

168

173

178

0 5 10 15 20 25 30

Ele

ctri

cty

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

300

320

340

360

380

400

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 12: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.4

LARGE INSTITUTIONAL ANNUAL ENERGY USE

Figure C1.3: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C1.4: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

172

177

182

187

192

0 5 10 15 20 25 30

Ele

ctri

cty

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

240

260

280

300

320

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 13: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.5

LARGE INSTITUTIONAL ANNUAL ENERGY USE

Figure C1.5: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C1.6: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

167

172

177

182

187

0 5 10 15 20 25 30

Ele

ctri

cty

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

240

260

280

300

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 14: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.6

2.0 LOW-MID RISE MURB ARCHETYPE SUMMARY

Archetype Symmary Values Units / Notes

Gross Floor Area (GFA) 51, 200 (4,757) ft2 (m2)

Number of Floors 4

Wall Height 9 (2.74) ft (m)

Window:Wall Ratio (WWR) 30% / 50%

Length:Width Ratio 2:1

Wall:Roof Ratio 1.35

Lighting Power Density (LPD) 0.7 (8) W/ft2 (W/m2)

Plug Power Density (PPD) 0.5 (6) W/ft2 (W/m2)

General System Information Electric Baseboard, Gas-Fired MUA, Gas DHW

Performance Details As per below According to standard practice

Zoning 15 5/floor, multiplier for middle floors

Notes Typical of a wood frame MURB

Building Envelope Components

Roof (insulated entirely above deck) 20.8 (3.66) R-value, h.ft2.F/BTU (m2.K/W)

Wall 23.7 (4.17) R-value Curve, h.ft2.F/BTU (m2.K/W)

Slab-on-grade (unheated) 0.159 (0.9) F-factor, BTU/h.ft.F (m.K/W)

Glazing (Double-pane) 0.387 (2.2) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Internal Loads

Occupancy 4 (25) person/100 ft2 (m2/person)

Lighting 0.7 (8) W/ft2 (W/m2)

Receptacle 0.5 (6) W/ft2 (W/m2)

Domestic Hot Water Peak 1,707 (500) BTUh/person (W/person)

Air Infiltration 0.05 (0.25) cfm/ft2 (L/s/m2) external surface area

Ventilation Rates

People Outdoor Air Rate 5 (2.5) cfm/person (L/s/person)

Area Outdoor Air Rate 0.06 (0.3) cfm/ft2 (L/s/m2)

Schedules

HVAC, Plug Loads, Lighting, Occupancy, Domestic

Hot Water

Hotel ASHRAE 90.1 - User's Manual, Table G-G

Zone Level Equipment

Heating Equipment

Equipment Type Electric Baseboard

Efficiency 100 %

Building Level Equipment

System Type MUA

Fan Control Constant Volume

Fan Efficiency 65 %

Motor Efficiency 90 %

Fan Static Pressure 4 (1,000) in (Pa)

Total Supply Airflow Autosized, 100% OA

Heating Equipment

Equipment Type Gas Coil

Efficiency 80 %

Controls

Heating Supply Air Temperature 64.4 (18) F (°C)

Plant Level Equipment

SHW Equipment

System Type and Fuel Gas

Efficiency 80 %

Peak Demand 1,707 (500) BTUh/person (W/person)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 15: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.7

LOW-MID RISE MURB ANNUAL ENERGY USE

Figure C2.1: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C2.2: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

60

80

100

120

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

150

152

154

156

158

160

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 16: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.8

LOW-MID RISE MURB ANNUAL ENERGY USE

Figure C2.3: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C2.4: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

50

60

70

80

90

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

126

128

130

132

134

136

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 17: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.9

LOW-MID RISE MURB ANNUAL ENERGY USE

Figure C2.5: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C2.6: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

50

60

70

80

90

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

121

123

125

127

129

131

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

50% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 18: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.10

3.0 HIGH RISE MURB ARCHETYPE SUMMARY

Archetype Symmary Values Units / Notes

Gross Floor Area (GFA) 300,000 (27,871) ft2 (m2)

Number of Floors 30

Wall Height 9 (2.74) ft (m)

Window:Wall Ratio (WWR) 40% / 70%

Length:Width Ratio 1:1

Wall:Roof Ratio 10.80

Lighting Power Density (LPD) 0.7 (8) W/ft2 (W/m2)

Plug Power Density (PPD) 0.5 (6) W/ft2 (W/m2)

General System Information Electric Baseboard, Gas-Fired MUA, Gas DHW.

Performance Details As per below According to standard practice

Zoning 15 5/floor, multiplier for middle floors

Notes Representative of point tower

Building Envelope Components

Roof (insulated entirely above deck) 20.8 (3.66) R-value, h.ft2.F/BTU (m2.K/W)

Wall 23.7 (4.17) R-value Curve, h.ft2.F/BTU (m2.K/W)

Slab-on-grade (unheated) 0.159 (0.9) F-factor, BTU/h.ft.F (m.K/W)

Glazing (Double-pane) 0.387 (2.2) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Glazing (Triple-pane) 0.282 (1.6) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Internal Loads

Occupancy 4 (25) person/100 ft2 (m2/person)

Lighting 0.7 (8) W/ft2 (W/m2)

Receptacle 0.5 (6) W/ft2 (W/m2)

Domestic Hot Water Peak 1,707 (500) BTUh/person (W/person)

Air Infiltration 0.05 (0.25) cfm/ft2 (L/s/m2) external surface area

Ventilation Rates

People Outdoor Air Rate 5 (2.5) cfm/person (L/s/person)

Area Outdoor Air Rate 0.06 (0.3) cfm/ft2 (L/s/m2)

Schedules

HVAC, Plug Loads, Lighting, Occupancy, Domestic

Hot Water

Hotel ASHRAE 90.1 - User's Manual, Table G-G

Zone Level Equipment

Heating Equipment

Equipment Type Electric Baseboard

Efficiency 100 %

Building Level Equipment

System Type MUA

Fan Control Constant Volume

Fan Efficiency 65 %

Motor Efficiency 90 %

Fan Static Pressure 4 (1,000) in (Pa)

Total Supply Airflow Autosized, 100% OA

Heating Equipment

Equipment Type Gas Coil

Efficiency 80 %

Controls

Heating Supply Air Temperature 64.4 (18) F (°C)

Plant Level Equipment

SHW Equipment

System Type and Fuel Gas

Efficiency 80 %

Peak Demand 1,707 (500) BTUh/person (W/person)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 19: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.11

HIGH RISE MURB ANNUAL ENERGY USE

Figure C3.1: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C3.2: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

60

70

80

90

100

110

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

150

152

154

156

158

160

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 20: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.12

HIGH RISE MURB ANNUAL ENERGY USE

Figure C3.3: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C3.4: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

50

60

70

80

90

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

126

128

130

132

134

136

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 21: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.13

HIGH RISE MURB ANNUAL ENERGY USE

Figure C3.5: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C3.6: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

50

60

70

80

90

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

121

123

125

127

129

131

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 22: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.14

HIGH RISE MURB (TRIPLE-GLAZING) ANNUAL ENERGY USE

Figure C3.7: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C3.8: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

60

70

80

90

100

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

150

152

154

156

158

160

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 23: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.15

HIGH RISE MURB (TRIPLE-GLAZING) ANNUAL ENERGY USE

Figure C3.9: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C3.10: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

55

65

75

85

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

126

128

130

132

134

136

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 24: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.16

HIGH RISE MURB (TRIPLE-GLAZING) ANNUAL ENERGY USE

Figure C3.11: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C3.12: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

50

60

70

80

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

121

123

125

127

129

131

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 25: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.17

4.0 SECONDARY SCHOOL ARCHETYPE SUMMARY

Archetype Symmary Values Units / Notes

Gross Floor Area (GFA) 78,400 (7,284) ft2 (m2)

Number of Floors 2

Wall Height 12 (3.6) ft (m)

Window:Wall Ratio (WWR) 20% / 40%

Length:Width Ratio 2:1

Wall:Roof Ratio 0.51

Lighting Power Density (LPD) 1.2 (13) W/ft2 (W/m2)

Plug Power Density (PPD) 0.5 (6) W/ft2 (W/m2)

General System Information Packaged VAV, HW reheat, PSZ in gym

Performance Details As per below According to standard practice

Zoning 10 5/floor

Building Envelope Components

Roof (insulated entirely above deck) 20.8 (3.66) R-value, h.ft2.F/BTU (m2.K/W)

Wall 23.7 (4.17) R-value Curve, h.ft2.F/BTU (m2.K/W)

Slab-on-grade (unheated) 0.159 (0.9) F-factor, BTU/h.ft.F (m.K/W)

Glazing (Double-pane) 0.387 (2.2) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Internal Loads

Occupancy 35 (3) person/100 ft2 (m2/person)

Lighting 1.2 (13) W/ft2 (W/m2)

Receptacle 0.5 (6) W/ft2 (W/m2)

Domestic Hot Water Peak 205 (60) BTUh/person (W/person)

Air Infiltration 0.05 (0.25) cfm/ft2 (L/s/m2) external surface area

Ventilation Rates

People Outdoor Air Rate 5 (2.5) cfm/person (L/s/person)

Area Outdoor Air Rate 0.06 (0.3) cfm/ft2 (L/s/m2)

Schedules

HVAC, Plug Loads, Lighting, Occupancy, Domestic

Hot Water

School ASHRAE 90.1 - User's Manual, Table G-M

Zone Level Equipment

Heating Equipment

Equipment Type Hot Water Reheat Coil

Controls

Heating Design Supply Air Temperature 20 (11.1) Above Space Temperature, F (°C)

Building Level Equipment - General

System Type PVAV

Fan Control ASHRAE VFD Curve Variable

Fan Efficiency 65 %

Motor Efficiency 90 %

Total Static Pressure 3 (750) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil

Heating Coil Inlet Water Temperature 180 (82.2) F (°C)

Heating Coil Outlet Water Temperature 130 (54.4) F (°C)

Heating Coil Inlet Air Temperature 62 (16.6) F (°C)

Heating Coil Outlet Air Temperature 90 (32.2) F (°C)

Cooling Equipment

Equipment Type Two-speed DX

Efficiency 2.78 COP

Equipment Type Single-speed DX

Efficiency 3.22 COP

Controls

Heating Sypply Air Temperature 50 (10) F (°C)

Cooling Supply Air Temperature Min 55, Max 64.4 (Min 12.8, Max 18) Reset for Warmest Zone, F (°C)

Outdoor Air Economizer 75 (24) Fixed Dry Bulb, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 26: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.18

Building Level Equipment - Gym

System Type PSZ (Unitary)

Fan Control On/Off

Fan Efficiency 65 %

Motor Efficiency 90 %

Total Static Pressure 3 (750) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil

Heating Coil Inlet Water Temperature 180 (82.2) F (°C)

Heating Coil Outlet Water Temperature 130 (54.4) F (°C)

Heating Coil Inlet Air Temperature 62 (16.6) F (°C)

Heating Coil Outlet Air Temperature 90 (32.2) F (°C)

Cooling Equipment

Equipment Type Single-speed DX

Efficiency 3.22 COP

Controls

Heating Supply Air Temperature Min 55.4, Max 113 (Min 13, Max 45) Single Zone Reheat Range, F (°C)

Plant Level Equipment

Heating Equipment

System Type Gas Boiler

Efficiency 80 %

Design Water Outlet Temperature 177.8 (81) F (°C)

Hot Water Pump

Pump Control Riding the Curve

Pump Configuration Primary Only

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

SHW Equipment

System Type and Fuel Gas

Efficiency 80 %

Peak Demand 205 (60) BTUh/person (W/person)

Controls

Hot Water Design Exit Temperature 180 (82) F (°C)

Hot Water Loop Design Temperature Difference 20 (11) F (°C)

Hot Water Loop Temperature Min 150, Max 180 (Min 66, Max 82) Outdoor Air Reset, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 27: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.19

SECONDARY SCHOOL ANNUAL ENERGY USE

Figure C4.1: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C4.2: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

70

72

74

76

78

80

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR

20% WWR

110

130

150

170

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR

20% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 28: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.20

SECONDARY SCHOOL ANNUAL ENERGY USE

Figure C4.3: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C4.4: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

72

74

76

78

80

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR

20% WWR

80

90

100

110

120

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR

20% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 29: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.21

SECONDARY SCHOOL ANNUAL ENERGY USE

Figure C4.5: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C4.6: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

68

70

72

74

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR

20% WWR

70

80

90

100

110

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

40% WWR

20% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 30: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.22

5.0 REC CENTRE ARCHETYPE SUMMARY

Archetype Symmary Values Units / Notes

Gross Floor Area (GFA) 60,000 (5,574) ft2 (m2)

Number of Floors 1

Wall Height 15 (4.57) ft (m)

Window:Wall Ratio (WWR) 30% / 60%

Length:Width Ratio 1.5:1

Wall:Roof Ratio 0.25

Lighting Power Density (LPD) 1.1 (12) W/ft2 (W/m2)

Plug Power Density (PPD) 0.75 (9) W/ft2 (W/m2)

General System Information Pool System (dry-o-tron or similar), PVAV

elsewhere

Performance Details As per below According to standard practice

Zoning5

Large perimeter zone for pool, 1 for core, 3 perimeter

for remaining

Notes Pool Rec Centre

Building Envelope Components

Roof (insulated entirely above deck) 20.8 (3.66) R-value, h.ft2.F/BTU (m2.K/W)

Wall 23.7 (4.17) R-value Curve, h.ft2.F/BTU (m2.K/W)

Slab-on-grade (unheated) 0.159 (0.9) F-factor, BTU/h.ft.F (m.K/W)

Glazing (Double-pane) 0.387 (2.2) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Internal Loads

Occupancy 20 (5) person/100 ft2 (m2/person)

Lighting 1.1 (12) W/ft2 (W/m2)

Receptacle 0.75 (9) W/ft2 (W/m2)

Domestic Hot Water Peak 307 (90) BTUh/person (W/person)

Air Infiltration 0.05 (0.25) cfm/ft2 (L/s/m2) external surface area

Ventilation Rates

People Outdoor Air Rate 5 (2.5) cfm/person (L/s/person)

Area Outdoor Air Rate 0.06 (0.3) cfm/ft2 (L/s/m2)

Schedules

HVAC, Plug Loads, Lighting, Occupancy, Domestic

Hot Water

Assembly ASHRAE 90.1 - User's Manual, Table G-E

Zone Level Equipment

Heating Equipment

Equipment Type Hot Water Reheat Coil

Controls

Heating Design Supply Air Temperature 20 (11.1) Above Space Temperature, F (°C)

Building Level Equipment - General

System Type PVAV

Fan Control ASHRAE VFD Curve Variable

Fan Efficiency 65 %

Motor Efficiency 90 %

Total Static Pressure 3 (750) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil

Heating Coil Inlet Water Temperature 180 (82.2) F (°C)

Heating Coil Outlet Water Temperature 130 (54.4) F (°C)

Heating Coil Inlet Air Temperature 62 (16.6) F (°C)

Heating Coil Outlet Air Temperature 90 (32.2) F (°C)

Cooling Equipment

Equipment Type Two-speed DX

Efficiency 2.87 COP

Controls

Heating Supply Air Temperature 50 (10) F (°C)

Cooling Supply Air Temperature Min 55, Max 64.4 (Min 12.8, Max 18) Reset for Warmest Zone, F (°C)

Outdoor Air Economizer 75 (24) Fixed Dry Bulb, Maximum Temperature, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 31: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.23

Building Level Equipment - Gym

System Type PSZ (Unitary)

Fan Control On/Off

Fan Efficiency 65 %

Motor Efficiency 90 %

Total Static Pressure 3 (750) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil

Heating Coil Inlet Water Temperature 180 (82.2) F (°C)

Heating Coil Outlet Water Temperature 130 (54.4) F (°C)

Heating Coil Inlet Air Temperature 62 (16.6) F (°C)

Heating Coil Outlet Air Temperature 90 (32.2) F (°C)

Cooling Equipment

Equipment Type Single-speed DX

Efficiency 3.22 COP

Controls

Heating Supply Air Temperature Min 55.4, Max 113 (Min 13, Max 45) Single Zone Reheat Range, F (°C)

Building Level Equipment - Pool

System Type PSZ (Unitary)

Fan Control On/Off

Fan Efficiency 65 %

Motor Efficiency 90 %

Total Static Pressure 3 (750) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil

Heating Coil Inlet Water Temperature 180 (82.2) F (°C)

Heating Coil Outlet Water Temperature 130 (54.4) F (°C)

Heating Coil Inlet Air Temperature 62 (16.6) F (°C)

Heating Coil Outlet Air Temperature 90 (32.2) F (°C)

Cooling Equipment

Equipment Type Single-speed DX

Efficiency 2.87 COP

Controls

Dehumidification Setpoint 60 % RH

Dehumidification Control Type Cool Reheat

Heating Supply Air Temperature Min 55.4, Max 113 (Min 13, Max 45) Single Zone Reheat Range, F (°C)

Plant Level Equipment

Heating Equipment

Equipment Type Gas Boiler

Efficiency 80 %

Design Water Outlet Temperature 177.8 (81) F (°C)

Hot Water Pump

Pump Control Riding the Curve

Pump Configuration Primary Only

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

SHW Equipment

System Type and Fuel Gas

Efficiency 80 %

Peak Demand 307 (90) BTUh/person (W/person)

Controls

Hot Water Design Exit Temperature 180 (82) F (°C)

Hot Water Loop Design Temperature Difference 20 (11) F (°C)

Hot Water Loop Temperature Min 150, Max 180 (Min 66, Max 82) Outdoor Air Reset, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 32: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.24

REC CENTRE ANNUAL ENERGY USE

Figure C5.1: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C5.2: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

134

136

138

140

142

144

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

240

250

260

270

280

290

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 33: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.25

REC CENTRE ANNUAL ENERGY USE

Figure C5.3: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C5.4: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

137

139

141

143

145

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

210

220

230

240

250

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 34: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.26

REC CENTRE ANNUAL ENERGY USE

Figure C5.5: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C5.6: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

135

136

137

138

139

140

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

210

220

230

240

250

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 35: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.27

6.0 COMMERCIAL OFFICE ARCHETYPE SUMMARY

Archetype Symmary Values Units / Notes

Gross Floor Area (GFA) 196,000 (18,209) ft2 (m2)

Number of Floors 10

Wall Height 12 (3.6) ft (m)

Window:Wall Ratio (WWR) 40% / 70%

Length:Width Ratio 1:1

Wall:Roof Ratio 3.43

Lighting Power Density (LPD) 1 (11) W/ft2 (W/m2)

Plug Power Density (PPD) 0.75 (9) W/ft2 (W/m2)

General System Information Boiler/Chiller/CT Plant, VAV Reheat

Performance Details As per below According to standard practice

Zoning 15 5/floor, multiplier for middle floors

Building Envelope Components

Roof (insulated entirely above deck) 20.8 (3.66) R-value, h.ft2.F/BTU (m2.K/W)

Wall 23.7 (4.17) R-value Curve, h.ft2.F/BTU (m2.K/W)

Slab-on-grade (unheated) 0.159 (0.9) F-factor, BTU/h.ft.F (m.K/W)

Glazing (Double-pane) 0.387 (2.2) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Glazing (Triple-pane) 0.282 (1.6) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Internal Loads

Occupancy 5 (20) person/100 ft2 (m2/person)

Lighting 1 (11) W/ft2 (W/m2)

Receptacle 0.75 (9) W/ft2 (W/m2)

Domestic Hot Water Peak 307 (90) BTUh/person (W/person)

Air Infiltration 0.05 (0.25) cfm/ft2 (L/s/m2) external surface area

Ventilation Rates

People Outdoor Air Rate 5 (2.5) cfm/person (L/s/person)

Area Outdoor Air Rate 0.06 (0.3) cfm/ft2 (L/s/m2)

Schedules

HVAC, Plug Loads, Lighting, Occupancy, Domestic

Hot Water

Office ASHRAE 90.1 - User's Manual, Table G-I

Zone Level Equipment

Heating Equipment

Equipment Type Hot Water Reheat Coil

Controls

Heating Design Supply Air Temperature 20 (11.1) Above Space Temperature, F (°C)

Building Level Equipment

System Type VAV

Fan Control ASHRAE VFD Curve Variable

Fan Efficiency 70 %

Motor Efficiency 90 %

Total Static Pressure 4 (1000) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil

Heating Coil Inlet Water Temperature 180 (82.2) F (°C)

Heating Coil Outlet Water Temperature 130 (54.4) F (°C)

Heating Coil Inlet Air Temperature 62 (16.6) F (°C)

Heating Coil Outlet Air Temperature 90 (32.2) F (°C)

Cooling Equipment

Equipment Type Chilled Water Coil

Controls

Heating Supply Air Temperature 50 (10) F (°C)

Cooling Supply Air Temperature Min 55, Max 64.4 (Min 12.8, Max 18) Reset for Warmest Zone, F (°C)

Outdoor Air Economizer 75 (24) Fixed Dry Bulb, Maximum Temperature, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 36: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.28

Plant Level Equipment

Heating Equipment

Equipment Type Gas Boiler

Efficiency 80 %

Design Water Outlet Temperature 177.8 (81) F (°C)

Hot Water Pump

Pump Control Constant Speed

Pump Configuration Primary Only

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

Cooling Equipment

Equipment Type Electric Chiller

Efficiency 5.67 COP

Condenser Type Water Cooled

Chiller Flow Mode Constant

Leaving Chilled Water Temperature 44 (6.67) F (°C)

Entering Condenser Fluid Temperature 85 (29.4) F (°C)

Chilled Water Pump

Pump Control Constant Speed

Pump Configuration Primary Only

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

Heat Rejection Equipment

Equipment Type Cooling Tower

Design Inlet Air Wet-Bulb Temperature 78 (25.6) F (°C)

Design Approach Temperature 7 (3.9) Difference, F (°C)

Design Range Temperature 10 (5.6) Difference, F (°C)

Condenser Pump

Pump Control VFD

Pump Configuration Primary Only

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

SHW Equipment

System Type and Fuel Gas

Efficiency 80 %

Peak Demand 307 (90) BTUh/person (W/person)

Controls

Hot Water Design Exit Temperature 180 (82) F (°C)

Hot Water Loop Design Temperature Difference 20 (11) F (°C)

Chilled Water Design Exit Temperature 45 (7.22) F (°C)

Chilled Water Loop Design Temperature Difference 44 (6.67) F (°C)

Condenser Water Design Exit Temperature 85 (29.4) F (°C)

Condenser Loop Design Temperature Difference 42 (5.6) F (°C)

Hot Water Loop Temperature Min 150, Max 180 (Min 66, Max 82) Outdoor Air Reset, F (°C)

Chilled Water Loop Temperature Min 45, Max 54 (Min 7, Max 12) Outdoor Air Reset, F (°C)

Condenser Water Loop Temperature Min 70, Max 84 (Min 21, Max 29) Follow Outdoor Air, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 37: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.29

COMMERCIAL OFFICE ANNUAL ENERGY USE

Figure C6.1: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C6.2: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

110

115

120

125

130

135

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

55

65

75

85

95

105

115

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 38: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.30

COMMERCIAL OFFICE ANNUAL ENERGY USE

Figure C6.3: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C6.4: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

115

120

125

130

135

140

145

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

30

40

50

60

70

80

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 39: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.31

COMMERCIAL OFFICE ANNUAL ENERGY USE

Figure C6.5: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C6.6: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

105

110

115

120

125

130

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

30

40

50

60

70

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 40: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.32

COMMERCIAL OFFICE (TRIPLE-GLAZING) ANNUAL ENERGY USE

Figure C6.7: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C6.8: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

110

115

120

125

130

135

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

50

60

70

80

90

100

110

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 41: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.33

COMMERCIAL OFFICE (TRIPLE-GLAZING) ANNUAL ENERGY USE

Figure C6.9: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C6.10: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

115

120

125

130

135

140

145

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

30

40

50

60

70

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 42: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.34

COMMERCIAL OFFICE (TRIPLE-GLAZING) ANNUAL ENERGY USE

Figure C6.11: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C6.12: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

105

110

115

120

125

130

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

20

30

40

50

60

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 43: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.35

7.0 HOTEL ARCHETYPE SUMMARY

Archetype Symmary Values Units / Notes

Gross Floor Area (GFA) 121,000 (11,241) ft2 (m2)

Number of Floors 10

Wall Height 10 (3.1) ft (m)

Window:Wall Ratio (WWR) 40% / 70%

Length:Width Ratio 1:1

Wall:Roof Ratio 3.64

Lighting Power Density (LPD) 1 (11) W/ft2 (W/m2)

Plug Power Density (PPD) 0.25 (3) W/ft2 (W/m2)

General System Information FPFC, Boiler, AC Chiller

Performance Details As per below According to standard practice

Zoning 15 5/floor, multiplier for middle floors

Building Envelope Components

Roof (insulated entirely above deck) 20.8 (3.66) R-value, h.ft2.F/BTU (m2.K/W)

Wall 23.7 (4.17) R-value Curve, h.ft2.F/BTU (m2.K/W)

Slab-on-grade (unheated) 0.159 (0.9) F-factor, BTU/h.ft.F (m.K/W)

Glazing (Double-pane) 0.387 (2.2) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Internal Loads

Occupancy 5 (20) person/100 ft2 (m2/person)

Lighting 1 (11) W/ft2 (W/m2)

Receptacle 0.25 (3) W/ft2 (W/m2)

Domestic Hot Water Peak 1,707 (500) BTUh/person (W/person)

Air Infiltration 0.05 (0.25) cfm/ft2 (L/s/m2) external surface area

Ventilation Rates

People Outdoor Air Rate 5 (2.5) cfm/person (L/s/person)

Area Outdoor Air Rate 0.06 (0.3) cfm/ft2 (L/s/m2)

Schedules

HVAC, Plug Loads, Lighting, Occupancy, Domestic

Hot Water

Hotel ASHRAE 90.1 - User's Manual, Table G-G

Zone Level Equipment

System Type Four Pipe Fan Coil (FPFC)

Fan Control On/Off

Fan Efficiency 70 %

Motor Efficiency 90 %

Total Static Pressure 0.028 (75) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil in FPFC

Cooling Equipment

Equipment Type Chilled Water Coil in FPFC

Controls

Heating Design Supply Air Temperature 20 (11.1) Above Space Temperature, F (°C)

Cooling Design Supply Air Temperature 55 (12.8) F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 44: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.36

Building Level Equipment

System Type MUA

Fan Control Constant Volume

Fan Efficiency 65 %

Motor Efficiency 90 %

Total Static Pressure 3 (750) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Hot Water Coil in MUA

Heating Coil Inlet Water Temperature 180 (82.2) F (°C)

Heating Coil Outlet Water Temperature 160 (71.1) F (°C)

Heating Coil Inlet Air Temperature 61 (16.6) F (°C)

Heating Coil Outlet Air Temperature 90 (32.2) F (°C)

Cooling Equipment

MUA Cooling Coil Chilled Water Coil in MUA

Controls

Heating Supply Air Temperature 54 (12.2) F (°C)

Cooling Supply Air Temperature Min 55, Max 64.4 (Min 12.8, Max 18) Reset for Warmest Zone, F (°C)

Outdoor Air Economizer 75 (24) Fixed Dry Bulb, Maximum Temperature, F (°C)

Plant Level Equipment

Heating Equipment

Equipment Type Gas Boiler

Efficiency 80 %

Design Water Outlet Temperature 180 (82) F (°C)

Hot Water Pump

Pump Control VFD

Pump Configuration Primary Only

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

Cooling Equipment

Equipment Type Electric Chiller

Efficiency 2.78 COP

Condenser Type Air Cooled

Chiller Flow Mode Constant

Leaving Chilled Water Temperature 44 (6.67) F (°C)

Entering Condenser Fluid Temperature N/A Air Cooled

Chilled Water Pump

Pump Control VFD

Pump Configuration Primary and Secondary

Pump Motor Efficiency 90 %

Pump Head 60 (180) ft (kPa)

Heat Rejection Equipment

Equipment Type Cooling Tower

SHW Equipment

Equipment Type Gas

Efficiency 80 %

Peak Demand 1,707 (500) BTUh/person (W/person)

Controls

Hot Water Design Exit Temperature 180 (82) F (°C)

Hot Water Loop Design Temperature Difference 20 (11) F (°C)

Chilled Water Design Exit Temperature 45 (7.22) F (°C)

Chilled Water Loop Design Temperature Difference 44 (6.67) F (°C)

Hot Water Loop Temperature Min 150, Max 180 (Min 66, Max 82) Outdoor Air Reset, F (°C)

Chilled Water Loop Temperature Min 45, Max 54 (Min 7, Max 12) Outdoor Air Reset, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 45: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.37

HOTEL ANNUAL ENERGY USE

Figure C7.1: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C7.2: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

70

80

90

100

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

190

200

210

220

230

240

250

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 46: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.38

HOTEL ANNUAL ENERGY USE

Figure C7.3: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C7.4: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

70

80

90

100

110

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

150

160

170

180

190

200

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 47: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.39

HOTEL ANNUAL ENERGY USE

Figure C7.5: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C7.6: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

70

80

90

100

110

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

140

150

160

170

180

190

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

70% WWR

40% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 48: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.40

8.0 NON-FOOD RETAIL ARCHETYPE SUMMARY

Archetype Symmary Values Units / Notes

Gross Floor Area (GFA) 48, 400 (4,497) ft2 (m2)

Number of Floors 1

Wall Height 20 (6.1) ft (m)

Window:Wall Ratio (WWR) 30%/60% storefront, 0% other

Length:Width Ratio 1:1

Wall:Roof Ratio 0.36

Lighting Power Density (LPD) 1.5 (17) W/ft2 (W/m2)

Plug Power Density (PPD) 0.25 (3) W/ft2 (W/m2)

General System Information PSZ-AC, gas fired heat

Performance Details As per below According to standard practice

Zoning 5 Core/perimeter

Notes Big Box Retail Type, glazing ratio is on storefront

elevation only, 0% glazing other elevations

Building Envelope Components

Roof (insulated entirely above deck) 20.8 (3.66) R-value, h.ft2.F/BTU (m2.K/W)

Wall 23.7 (4.17) R-value Curve, h.ft2.F/BTU (m2.K/W)

Slab-on-grade (unheated) 0.159 (0.9) F-factor, BTU/h.ft.F (m.K/W)

Glazing (Double-pane) 0.387 (2.2) U-value, BTU/h.ft2.F (m2.K/W)

0.45 Solar Heat Gain Coefficient (SHGC)

Internal Loads

Occupancy 15 (6.7) person/100 ft2 (m2/person)

Lighting 1.5 (17) W/ft2 (W/m2)

Receptacle 0.25 (3) W/ft2 (W/m2)

Domestic Hot Water Peak 137 (40) BTUh/person (W/person)

Air Infiltration 0.05 (0.25) cfm/ft2 (L/s/m2) external surface area

Ventilation Rates

People Outdoor Air Rate 5 (2.5) cfm/person (L/s/person)

Area Outdoor Air Rate 0.06 (0.3) cfm/ft2 (L/s/m2)

Schedules

HVAC, Plug Loads, Lighting, Occupancy, Domestic

Hot Water

Retail ASHRAE 90.1 - User's Manual, Table G-L

Zone Level Equipment

Controls

Heating Design Supply Air Temperature 122 (50) F (°C)

Cooling Design Supply Air Temperature 55 (12.8) F (°C)

Building Level Equipment

System Type PSZ-AC (One Per Zone) Unitary Furnace:HeatCool

Fan Control Constant Volume

Fan Efficiency 70 %

Motor Efficiency 90 %

Total Static Pressure 2.4 (600) in (Pa)

Total Supply Airflow Autosized

Heating Equipment

Equipment Type Gas

Efficiency 80 %

Cooling Equipment

Equipment Type DX

Efficiency 3 COP

SHW Equipment

System Type and Fuel Gas

Efficiency 80 %

Peak Demand 137 (40) BTUh/person (W/person)

Controls

Heating Supply Air Temperature Min 55.4, Max 113 (Min 13, Max 45) Single Zone Reheat Range, F (°C)

Cooling Supply Air Temperature Min 55, Max 64.4 (Min 12.8, Max 18) Reset for Warmest Zone, F (°C)

Outdoor Air Economizer 75 (24) Fixed Dry Bulb, Maximum Temperature, F (°C)

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 49: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.41

NON-FOOD RETAIL ANNUAL ENERGY USE

Figure C8.1: Prince George – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C8.2: Prince George – Gas Use vs. Opaque Wall Assembly R-Value

88

90

92

94

96

98

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

140

160

180

200

220

240

260

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 50: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.42

NON-FOOD RETAIL ANNUAL ENERGY USE

Figure C8.3: Summerland – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C8.4: Summerland – Gas Use vs. Opaque Wall Assembly R-Value

94

96

98

100

102

104

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

90

110

130

150

170

190

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE

Page 51: APPENDIX C ENERGY MODELING ANALYSIS AND RESULTS€¦ · Building Envelope Thermal Bridging Guide C.v THERMAL MASS ANALYSIS ANNUAL ENERGY USE Figure C0.5: Summerland – Electricity

Building Envelope Thermal Bridging Guide

C.43

NON-FOOD RETAIL ANNUAL ENERGY USE

Figure C8.5: Vancouver – Electricity Use vs. Opaque Wall Assembly R-Value

Figure C8.6: Vancouver – Gas Use vs. Opaque Wall Assembly R-Value

85

87

89

91

93

95

0 5 10 15 20 25 30

Ele

lctr

icit

y U

se (

ekW

h/m

2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

70

90

110

130

150

170

0 5 10 15 20 25 30

Gas

Use

(e

kWh

/m2)

Opaque Wall Assembly R-value (ft2-F-hr/Btu)

60% WWR

30% WWR

Appendix C ­ Energy Modeling Analysis and Results BUILDING ENVELOPE THERMAL BRIDGING GUIDE