2
Product description The Karl Fischer Titrator AQUA 40.00 coupled with a LPG/LNG module is designed for an easy and accurate determination of water in liquefied and gaseous samples such as LPG and LNG. These device versions of AQUA 40.00 are suitable for all types of gases - flammable, inert as well as changing mixtures. A large sample loop ensures precise gas dosage. The determination of pressure is carried out in the sample loop, so no additional rinsing gas is needed. The output results can be adjusted to your needs by using a formula generator. The device can also be used in a carrying case for on-site measurements. Advantages ! Universal gas dosing module ! Fully-automatic measurement ! Precise and automatic gas volume measurement ! No adjustment to changing of the sample is required ! No calibration of the flow regulator is required ! Freely adjustable gas sample volume AQUA 40.00 coupled with the LPG/LNG module in a carrying case LPG/LNG Module for the determination of moisture in gases aqua 40.00 Applications Suitable for all types of gases Analysis of liquefied gases: ! LPG, LNG ! propane, propene, butane, butene, butadiene ! ethylene oxide ! chlorinated hydrocarbons, e. g. methylene chloride, ethylene chloride, vinyl chloride ! refrigerants: halogenated hydrocarbons Analysis of permanent gases, e. g. natural gas, technical gases and mixtures of test gases Gas flow regulator Gas dosing valve Sample loop Sample cylinder with valve Quick connector Expansion module Sampling module AQUA 40.00 basic module ! No rinsing gas is needed ! Long life of the electrolyte Clear software ! Device can be combined with other modules ! Compact and portable device in combination with carrying case !

aqua lpg module - Ayalytical...The Karl Fischer Titrator AQUA 40.00 coupled with a LPG/LNG module is designed for an easy and accurate determination of water in liquefied and gaseous

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

  • Product description

    The Karl Fischer Titrator AQUA 40.00 coupled with a LPG/LNG module is designed for an easy and accurate determination of water in liquefied and gaseous samples such as LPG and LNG.

    These device versions of AQUA 40.00 are suitable for all types of gases - flammable, inert as well as changing mixtures.

    A large sample loop ensures precise gas dosage. The determination of pressure is carried out in the sample loop, so no additional rinsing gas is needed.

    The output results can be adjusted to your needs by using a formula generator. The device can also be used in a carrying case for on-site measurements.

    Advantages

    ! Universal gas dosing module! Fully-automatic measurement! Precise and automatic gas volume measurement! No adjustment to changing of the sample is required! No calibration of the flow regulator is required! Freely adjustable gas sample volume

    AQUA 40.00 coupled with the LPG/LNG module in a carrying case

    LPG/LNG Modulefor the determination of moisture in gases

    aqua40.00

    Applications

    Suitable for all types of gases

    Analysis of liquefied gases:! LPG, LNG! propane, propene, butane, butene, butadiene! ethylene oxide! chlorinated hydrocarbons, e. g. methylene chloride,

    ethylene chloride, vinyl chloride! refrigerants: halogenated hydrocarbons

    Analysis of permanent gases, e. g. natural gas,technical gases and mixtures of test gases

    Gas flow regulator

    Gas dosing valve

    Sample loop

    Sample cylinderwith valve

    Quick connector

    Expansionmodule

    Samplingmodule

    AQUA 40.00basic module

    ! No rinsing gas is needed

    ! Long life of the electrolyteClear software

    ! Device can be combined with other modules! Compact and portable device in combination with

    carrying case

    !

  • Specifications

    Details

    !

    liquefied and gaseous samples! Determination of pressure in the sample loop! Automatic pressure regulation! Transfer line with direct injection! Automatic rinsing steps and bypass for rinsing

    Selective determination method for moisture in up to 200 bar

    We are here for you

    Fixing of sample cylinder by quick coupling

    Measurement method:Sample:Sample cylinder:Pressure reducer:Sample loop:Rinsing and dosing:Type of result:Measuring range:Resolution:Detection limit:Dimensions:Weight:Car adapter:

    coulometric titration pressurized gas sample (LNG, LPG)0.5 liter pressurized bottle or directly from the gas lineinternal (with heating element )500 ml (gas)0…15 steps for each, adjustableµg, ppm (gas volume) by using the formula generator1 … 10,000 ppm0.1 ppm1 ppm38 x 45 x 20 cm (L x H x D)8 kg12 V

    Measurement: automatic titration after enrichment

    ! Measuring cell without diaphragm (only one electrolyte required)

    ! Setting of application-specific methods! Each PC/laptop is suitable to control the device,

    (software for Windows-operating systems)! Laboratory and on site usage with carrying case

    Sample cylinder with valve

    ECH Elektrochemie Halle GmbHOtto-Eissfeldt-Str. 8D-06120 Halle (Saale)GermanyTel.: +49 345 279570-0Fax: +49 345 279570-99E-mail: [email protected]: www.ech.de