21
SECTION 08 71 13 AUTOMATIC DOOR OPERATORS Display hidden notes to specifier. (Don't know how? Click Here ) Copyright 2012 - 2016 ARCAT, Inc. - All rights reserved 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Low energy swing door operators. (HA-8) 1.1.2 Fully automatic swing door operators. (FA-8) 1.1.3 Low profile, low energy swing door operators. (LP-HA-8) 1.1.4 Automatic slide door operators. (DS-18C) 1.1.5 Access control slide door operators. (DS-18C) 1.1.6 Intensive care unit manual sliding door systems. (IC-18) 1.1.7 Intensive care unit manual fold-swing door systems. (FS-IC) 1.2 RELATED SECTIONS 1.2.1 Section 06 10 00 - Rough Carpentry. 1.2.2 Section 08 41 00 - Entrances and Storefronts. 1.2.3 Section 08 71 53 - Security Door Hardware. 1.2.4 Section 08 83 13 - Mirrored Glass Glazing. 1.2.5 Section 12 67 00 - Pews and Benches. 1.2.6 Section 26 05 00 - Common Work Results for Electrical. 1.2.7 Section 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. 1.3 REFERENCES 1.3.1 Americans with Disabilities Act (ADA). 1.3.2 Underwriters Laboratories, Inc. (UL): UL 325 - Door, Drapery, Gate, Louver, and Window Operators and Systems. 08 71 13-1

ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

SECTION 08 71 13AUTOMATIC DOOR OPERATORS

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2012 - 2016 ARCAT, Inc. - All rights reserved

1 GENERAL

1.1 SECTION INCLUDES

1.1.1 Low energy swing door operators. (HA-8)

1.1.2 Fully automatic swing door operators. (FA-8)

1.1.3 Low profile, low energy swing door operators. (LP-HA-8)

1.1.4 Automatic slide door operators. (DS-18C)

1.1.5 Access control slide door operators. (DS-18C)

1.1.6 Intensive care unit manual sliding door systems. (IC-18)

1.1.7 Intensive care unit manual fold-swing door systems. (FS-IC)

1.2 RELATED SECTIONS

1.2.1 Section 06 10 00 - Rough Carpentry.

1.2.2 Section 08 41 00 - Entrances and Storefronts.

1.2.3 Section 08 71 53 - Security Door Hardware.

1.2.4 Section 08 83 13 - Mirrored Glass Glazing.

1.2.5 Section 12 67 00 - Pews and Benches.

1.2.6 Section 26 05 00 - Common Work Results for Electrical.

1.2.7 Section 26 05 19 - Low-Voltage Electrical Power Conductors and Cables.

1.3 REFERENCES

1.3.1 Americans with Disabilities Act (ADA).

1.3.2 Underwriters Laboratories, Inc. (UL): UL 325 - Door, Drapery, Gate, Louver, and Window Operators and Systems.

1.3.3 Builders Hardware Manufacturers Association (BHMA):1.3.3.1 ANSI-BHMA A 156.10 - Power Operated Pedestrian Doors.1.3.3.2 ANSI-BHMA A 156.19 - Power Assist and Low Energy Power Operated Doors.

1.3.4 Canadian Standards Association: CSA C22.2 - Electrical Code.

1.3.5 American Association of Automatic Door Manufacturers (AAADM).

08 71 13-1

Page 2: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

1.4 SUBMITTALS

1.4.1 Submit under provisions of Section 01 30 00 - Administrative Requirements.

1.4.2 Product Data: Manufacturer's data sheets on each product to be used, including:1.4.2.1 Preparation instructions and recommendations.1.4.2.2 Storage and handling requirements and recommendations.1.4.2.3 Installation guides; installation and operating manuals and installation

recommendations.1.4.2.4 Cleaning methods.

1.4.3 Shop Drawings: Submit shop drawings showing layout, profiles, product components, accessories joining methods, location of components, anchorage details, interface with adjacent construction, dimensions and wiring details and electrical requirements.

1.4.4 Verification Samples: For each product and finish specified, two samples, sized to adequately represent material, representing actual products and finishes.

1.5 QUALITY ASSURANCE

1.5.1 Single Source Requirements: To the greatest extent practical provide products specified in this section from a single manufacturer or supplier.

1.5.2 Manufacturer: Minimum 5 years experience producing similar products.

1.5.3 Installer Qualifications: Acceptable to manufacturer.

1.6 DELIVERY, STORAGE, AND HANDLING

1.6.1 Deliver, store and handle materials and products in strict compliance with manufacturer's instructions and recommendations and industry standards.

1.6.2 Store materials in manufacturer's original sealed, labeled packaging until ready for installation and in accordance with manufacturer's instructions. Protect from damage.

1.7 PROJECT CONDITIONS

1.7.1 Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.

1.8 SEQUENCING AND SCHEDULING

1.8.1 Conference: Convene a pre-installation conference to establish procedures to maintain optimum working conditions and to coordinate this work with related and adjacent work.

1.9 WARRANTY

1.9.1 Manufacturer's standard 3-year limited warranty against defects in materials and workmanship.

2 PRODUCTS

2.1 MANUFACTURERS

2.1.1 Acceptable Manufacturer: DITEC Entrematic North America; 221A Racco Pkwy.; Vaughan, ON; Canada L4J8X9. Toll Free: 877-348-6837. Phone: 416-674-8880. Fax: 416-674-8882. Email: [email protected] Web Site: www.ditecentrematic.ca.

08 71 13-2

Page 3: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

2.1.2 Acceptable Manufacturer: DITEC Entrematic USA Inc; 240 Vista Park Drive, Pittsburgh, PA 15205. USA. Toll Free: 866-901-4284. Phone: 412-200-5750. Fax: 412-200-5751. Email: [email protected] Web Site: www.ditecentrematic.us.

2.1.3 Substitutions: Not permitted.

2.1.4 Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

2.2 LOW ENERGY SWING DOOR OPERATORS (HA-8)

2.2.1 Low Energy Swing Door Operators: Model HA-8 as manufactured by DITEC Entrematic North America.2.2.1.1 Components: Provide door operating equipment, controls and safety devices,

accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

2.2.1.2 System Design: Electro-mechanical system installed in header to resist dust, dirt and corrosion; removable from the header as a unit.

2.2.1.3 Operating Temperature Range: -30 degrees F to +130 degrees F (-34 degrees C to 54 degrees C).

2.2.1.4 Aluminum Extrusion Finish: As scheduled and indicated on Drawings.2.2.1.5 Aluminum Extrusion Finish: Standard, clear anodized.2.2.1.6 Aluminum Extrusion Finish: Standard, bronze anodized.2.2.1.7 Aluminum Extrusion Finish: Standard, light bronze anodized.2.2.1.8 Aluminum Extrusion Finish: Special anodized, color ___________.2.2.1.9 Aluminum Extrusion Finish: Painted, color ___________.2.2.1.10 Aluminum Extrusion Finish: Clad, ___________.2.2.1.11 Headers: Full length removable cover for access to operator, electronic control

box.2.2.1.11.1 Materials: 6063-T5 aluminum extrusions with structurally integrated end

caps.2.2.1.11.2 Dimensions: 4-1/2 inches (114 mm) wide by 6-1/2 inches (165 mm) high.2.2.1.11.3 Structural Sections: Minimum wall thickness of .125 inch (3.2 mm).

2.2.1.12 Linkage Assemblies: Shall provide positive control of door through entire swing.2.2.1.12.1 Surface applied permit use on butt-hung or offset pivots.2.2.1.12.2 Concealed permit use on center pivot, butt-hung, and offset pivots.

2.2.1.13 Bearings: Fully lubricated and sealed to minimize wear and friction.

2.2.2 Operation:2.2.2.1 Entrapment Protection Compliance: Door forces and speeds generated during

power opening and manual opening in both directions of swing and spring closing in both directions of swing shall conform to the requirements of ANSI A 156.19, UL 325, and Code of Federal Regulations, ADA Standards of Accessible Design paragraph 4.13.12.

2.2.2.2 Mode of Operation: To be "low energy" as defined by ANSI A 156.19.2.2.2.3 Electrical Controls: Electronic controllers with quick connect plugs shall

incorporate the features listed below.2.2.2.3.1 Responds to push plates, transmitters and receivers.2.2.2.3.2 Immediate reverse-on-obstruction during opening capability.2.2.2.3.3 Open, back check and closing speed adjustment.2.2.2.3.4 Adjustable time delays.2.2.2.3.5 On/Off/Hold-Open switch.

2.2.2.4 Drive Trains: Positive constant engagement; operator shall stop the door in the open position by electrically reducing the motor voltage and stalling against stop.

2.2.2.5 Power Opening: Operator shall open door with a motor through reduction gears splined spindle, door arm and linkage assembly.

2.2.2.5.1 Motor: As scheduled and indicated on Drawings.

08 71 13-3

Page 4: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

2.2.2.5.2 Motor: Standard, 1/5 HP motor.2.2.2.5.3 Motor: Provide optional 1/4 HP motor.

2.2.2.6 Spring Close: Closing spring shall be pre-loaded for positive closing action.2.2.2.6.1 Operator shall close door by spring energy.2.2.2.6.2 Employing the motor as a dynamic brake shall control closing speed.2.2.2.6.3 "Low energy" operator door closing time shall not be less than 4.5

seconds.2.2.2.7 Manual Operation: Operator shall function as a manual door closer in the

direction of swing with or without electrical power. To facilitate easy manual operation of door and to prolong gear and motor life, operator must have a one-way clutch in the gear train.

2.3 FULLY AUTOMATIC SWING OPERATOR (FA-8)

2.3.1 Fully Automatic Swing Door Operators: Model FA-8 as manufactured by DITEC Entrematic North America.2.3.1.1 Components: Provide door operating equipment, controls and safety devices,

accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

2.3.1.2 System Design: Electro-mechanical system installed in header to resist dust, dirt and corrosion; removable from the header as a unit.

2.3.1.3 Operating Temperature Range: -30 degrees F to +130 degrees F (-34 degrees C to 54 degrees C).

2.3.1.4 Aluminum Extrusion Finish: As scheduled and indicated on Drawings.2.3.1.5 Aluminum Extrusion Finish: Standard, clear anodized.2.3.1.6 Aluminum Extrusion Finish: Standard, bronze anodized.2.3.1.7 Aluminum Extrusion Finish: Standard, light bronze anodized.2.3.1.8 Aluminum Extrusion Finish: Special anodized, color ___________.2.3.1.9 Aluminum Extrusion Finish: Painted, color ___________.2.3.1.10 Aluminum Extrusion Finish: Clad, ___________.2.3.1.11 Headers: Full length removable cover for access to operator, electronic control

box.2.3.1.11.1 Materials: 6063-T5 aluminum extrusions with structurally integrated end

caps.2.3.1.11.2 Dimensions: 4-1/2 inches (114 mm) wide by 6-1/2 inches (165 mm) high.2.3.1.11.3 Structural Sections: Minimum wall thickness of .125 inch (3.2 mm).

2.3.1.12 Linkage Assemblies: Shall provide positive control of door through entire swing.2.3.1.12.1 Surface applied permit use on butt-hung or offset pivots.2.3.1.12.2 Concealed permit use on center pivot, butt-hung, and offset pivots.

2.3.1.13 Bearings: Fully lubricated and sealed to minimize wear and friction.

2.3.2 Operation:2.3.2.1 Entrapment Protection Compliance: Door forces and speeds generated during

power opening and manual opening in both directions of swing and spring closing in both directions of swing shall conform to the requirements of ANSI A 156.10.

2.3.2.2 Mode of Operation: To be "Full energy" as defined by ANSI A 156.10.2.3.2.3 Electrical Controls: Electronic controllers with quick connect plugs shall

incorporate the features listed below.2.3.2.3.1 Responds to push plates, transmitters, motion and presence detectors and

receivers.2.3.2.3.2 Immediate reverse-on-obstruction during opening capability.2.3.2.3.3 Open, back check and closing speed adjustment.2.3.2.3.4 Adjustable time delays.2.3.2.3.5 On/Off/Hold-Open switch.

2.3.2.4 Power Opening: Operator shall open door with a 1/5 HP motor through reduction

08 71 13-4

Page 5: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

gears splined spindle, door arm and linkage assembly. Drive train shall have positive constant engagement. Operator shall stop the door in the open position by electrically reducing the motor voltage and stalling against stop.

2.3.2.5 Spring Close: Operator shall close door by spring energy.2.3.2.5.1 Employing the motor as a dynamic brake shall control closing speed.2.3.2.5.2 Closing spring shall be pre-loaded for positive closing action.2.3.2.5.3 "Full energy" operator door closing time shall not be less than 4.5 seconds.

2.3.2.6 Manual Operation: Operator shall function as a manual door closer in the direction of swing with or without electrical power. To facilitate easy manual operation of door and to prolong gear and motor life, operator must have a one-way clutch in the gear train.

2.4 LOW PROFILE LOW ENERGY SWING OPERATOR (LP-HA-8)

2.4.1 Low Profile, Low Energy Swing Door Operators: Model LP-HA-8 as manufactured by DITEC Entrematic North America.2.4.1.1 Components: Provide door operating equipment, controls and safety devices,

accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

2.4.1.2 System Design: Electro-mechanical system installed in a header to resist dust, dirt and corrosion.

2.4.1.3 Operating Temperature Range: -30 degrees F to +130 degrees F (-34 degrees C to 54 degrees C).

2.4.1.4 Aluminum Extrusion Finish: As scheduled and indicated on Drawings.2.4.1.5 Aluminum Extrusion Finish: Standard, clear anodized.2.4.1.6 Aluminum Extrusion Finish: Standard, bronze anodized.2.4.1.7 Aluminum Extrusion Finish: Standard, light bronze anodized.2.4.1.8 Aluminum Extrusion Finish: Special anodized, color ___________.2.4.1.9 Aluminum Extrusion Finish: Painted, color ___________.2.4.1.10 Aluminum Extrusion Finish: Clad, ___________.2.4.1.11 Headers: Full length removable cover for access to operator, electronic control

box.2.4.1.11.1 Materials: 6063-T5 aluminum extrusions with structurally integrated end

caps.2.4.1.11.2 Dimensions: LOW PROFILE, 5 inches (127 mm) deep x 4 inches (102

mm) high x width of door opening plus 3 inches (76 mm).2.4.1.11.3 Removable Covers: Minimum wall thickness of .10 inches (2.5 mm); no

visible fasteners.2.4.1.11.4 Structural Back Plate Sections: Minimum wall thickness of .20 inch (5.1

mm).2.4.1.12 Linkage Assemblies: Shall provide positive control of door through entire swing.

2.4.1.12.1 Surface applied permit use on butt-hung or offset pivots.2.4.1.12.2 Linkage shall be capable of pushing or pulling the door to the open

position.2.4.1.13 Bearings: Fully lubricated and sealed to minimize wear and friction.

2.4.2 Operation:2.4.2.1 Entrapment Protection Compliance: Door forces and speeds generated during

power opening and manual opening in both directions of swing and spring closing in both directions of swing shall conform to the requirements of ANSI A 156.19.

2.4.2.2 Mode of Operation: To be "low energy" as defined by ANSI A 156.19.2.4.2.3 Electrical Controls: Electronic controllers with quick connect plugs shall

incorporate the features listed below.2.4.2.3.1 Responds to push plates, transmitters, and receivers.2.4.2.3.2 Reverse-on-obstruction during opening capability.

08 71 13-5

Page 6: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

2.4.2.3.3 Open, back check, and closing speed adjustment.2.4.2.3.4 Adjustable time delays.2.4.2.3.5 On/Off/Hold Open Switch.2.4.2.3.6 Push and Go feature is optional.

2.4.2.4 Drive Trains: Positive constant engagement. Operator shall stop the door in the open position by electrically reducing the motor voltage and stalling against internal stop. Power Opening: Electro-mechanical operator shall open door with a 1/8 HP motor through reduction gears splined spindle, door arm and linkage assembly.

2.4.2.5 Hydraulically or pneumatically opening door operators will not be acceptable.2.4.2.6 Spring Close: Operator shall close door by spring energy.

2.4.2.6.1 Employing the motor as a dynamic brake shall control closing speed.2.4.2.6.2 Closing spring shall be pre-loaded for positive closing action at low

material stress level.2.4.2.6.3 "Low energy" operator door closing time shall not be less than 4.5

seconds.2.4.2.6.4 Hydraulically or pneumatically closing operators will not be acceptable.

2.4.2.7 Manual Operation: Operator shall function as a manual door closer in the direction of swing with or without electrical power. To facilitate easy manual operation of door and to prolong gear and motor life, operator must have a one-way clutch in the gear train.

2.5 AUTOMATIC SLIDE DOOR OPERATORS (DS-18C)

2.5.1 Automatic Slide Door Operators: Model DS-18C as manufactured by DITEC Entrematic North America.2.5.1.1 Components: Provide door operating equipment, guide threshold, actuating and

safety controls, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

2.5.1.2 System Design: Components in the header factory engineered, assembled, adjusted and tested.

2.5.1.2.1 Field wiring consists of connection to job-site power and actuators.2.5.1.2.2 The bi-part sliding door system shall include a two-point MS deadlock

securing the lead edges of the door stiles together and to the active door carrier assembly or for single slide a one point MS deadlock securing the latch stile to the vertical lock jamb.

2.5.1.2.3 Each door panel shall include interlocking that securely latches the swing out panels to the sliding panels in the fully closed position.

2.5.1.2.4 The active sliding door shall be provided with a key cylinder on the exterior and a thumbturn on the interior.

2.5.1.3 Operating Temperature Range: System components shall operate between -70 degrees F and 130 degrees F (-56 degrees C and 54 degrees C).

2.5.1.4 Aluminum Extrusion Finish: As scheduled and indicated on Drawings.2.5.1.5 Aluminum Extrusion Finish: Standard, clear anodized.2.5.1.6 Aluminum Extrusion Finish: Standard, bronze anodized.2.5.1.7 Aluminum Extrusion Finish: Standard, light bronze anodized.2.5.1.8 Aluminum Extrusion Finish: Special anodized, color ___________.2.5.1.9 Aluminum Extrusion Finish: Painted, color ___________.2.5.1.10 Aluminum Extrusion Finish: Clad, ___________.2.5.1.11 Door Panels and Sidelights: Sized to prevent pinch points at meeting stiles.

2.5.1.11.1 Compliance: Allow "breakout" to full open position to provide instant egress at any point in door's movement.

2.5.1.11.2 Sliding Aluminum Doors: Narrow stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation; with intermediate rails.

2.5.1.11.3 Door Panels: Include interlocking that securely latches the fully closed

08 71 13-6

Page 7: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

position.2.5.1.11.4 Door Glass Thickness: As scheduled and indicated on Drawings.2.5.1.11.5 Door Glass Thickness: Stops for 1/4 inch (6 mm) glazing.2.5.1.11.6 Door Glass Thickness: Stops for 5/8 inch (16 mm) glazing.2.5.1.11.7 Aluminum Sidelights: Narrow stile through bolted units, to dimensions and

with glazing as scheduled and indicated on Drawings and order confirmation.

2.5.1.11.8 Sidelight Glass Thickness: As scheduled and indicated on Drawings.2.5.1.11.9 Sidelight Glass Thickness: Stops for 1/4 inch (6 mm) glazing.2.5.1.11.10 Sidelight Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

2.5.1.12 Aluminum Frames and Extrusions:2.5.1.12.1 Integral Structural Sections: Minimum .125 inch (3 mm) thickness.2.5.1.12.2 Dimensions: 4-1/2 inches (114 mm) deep x 1-3/4 inches wide (44 mm)

section.2.5.1.12.3 Transom Package: None.2.5.1.12.4 Transom Package: As scheduled and indicated on Drawings.2.5.1.12.5 Transom Package: One vertical transom tube, designed for 1/4 inch (6

mm) glazing.2.5.1.12.6 Transom Package: One vertical transom tube, designed for 1 inch (24 mm)

glazing.2.5.1.13 Header Cases:

2.5.1.13.1 Materials: Extruded aluminum.2.5.1.13.2 Size: 4-1/2 inches wide x 7-1/2 inches high (108 mm x 180 mm).2.5.1.13.3 Capacity: Header shall be capable of supporting a single door leaf of 250

pounds or bi-parting door leaf of 250 pounds each over a span of 18 ft (5.5 m) with deflection within limits established by manufacturer for product application.

2.5.1.13.4 Slide System: Digital slide system and door mounting components.2.5.1.13.5 Header Cover: With a continuous hinge, opens flush with top of header.

2.5.1.14 Door Hanger Wheels:2.5.1.14.1 Materials: Urethane.2.5.1.14.2 Diameter: 2-1/2 inch (64 mm).2.5.1.14.3 Bearings: Precision lifetime lubricated ball bearings.2.5.1.14.4 Anti Riser Blocks: 4 Delrin anti riser block per door, to secure sliding doors

to roller tracks, field replaceable.2.5.1.14.5 Adjustability: Doors can be adjusted down up to 1/2 inch (13 mm).

2.5.1.15 Guide Threshold Track: Guides slide panels from close to open and open to close.

2.5.1.15.1 Materials: Aluminum.2.5.1.15.2 Profiles: As scheduled and indicated on Drawings .2.5.1.15.3 Profiles: Recess mounted.2.5.1.15.4 Profiles: Surface mounted double bevel.2.5.1.15.5 Profiles: Surface mounted combination bevel/square; options are field

adjustable by snap-off beveled edge.2.5.1.16 Drive Systems: Digital Slide System.

2.5.1.16.1 Components: Electromechanical 1/5 hp, 100V, brushless DC motor and enclosed hypoid gear system with maximum opening speed of 750 mm/sec.

2.5.1.16.2 Power Requirements: Provide 120 VAC, 5 amps single-phase power supply minimum to operator transformer junction box within header.

2.5.1.17 Control Units: DS-18C Ferrite Chip Control Unit.2.5.1.17.1 Torque shall be factory set as prescribed by ANSI A156.10.2.5.1.17.2 In the event of power failure active doors maybe opened manually.2.5.1.17.3 Microprocessor Controls: Monitors doorway holding beams, door position,

electric lock position, activators, motor temperature, and condition of power.

08 71 13-7

Page 8: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

2.5.1.17.4 Self-Diagnostics: Checks performed on continuous basis, faults displayed by flashing LED's and buzzer noise on control panels.

2.5.1.18 Doorway Holding Beams:2.5.1.18.1 Factory installed at 24 inches (610 mm) and 48 inches (1219 mm) from

finished floor.2.5.1.18.2 When the beam is interrupted, an open door shall be inhibited from closing.

2.5.1.19 Switches: As scheduled and indicated on Drawings2.5.1.20 Switches: 10 position switch. (10PS)2.5.1.21 Switches: 10 position switch with key. (10PK)2.5.1.22 Switches: 3 position switch. (3PS)2.5.1.23 Switches: 3 position switch with key. (3PK)2.5.1.24 Switches: 4 position switch. (4PS)2.5.1.25 Switches: 4 position switch with key. (4PK)

2.5.2 Operation:2.5.2.1 Motion Detection: Actuated by motion detector mounted on each side of door

detection of traffic in each direction.2.5.2.2 Reverse Function:

2.5.2.2.1 Upon obstruction with Safety Search Circuitry.2.5.2.2.2 Doors shall recycle open if an object is encountered during closing cycle.2.5.2.2.3 Circuitry shall time-out for 5 seconds then search for that object at 50

percent speed on next closing cycle.2.5.2.2.4 If an obstruction is encountered again, doors will recycle open.2.5.2.2.5 Doors shall keep timing-out and recycling at 50 percent speed until

obstruction is cleared.2.5.2.2.6 If an object is encountered while opening, the doors will stop, reverse

direction one inch, time-out for 5 seconds and close at 50 percent speed.2.5.2.2.7 The next opening the circuitry shall search for that object at 50 percent

speed.2.5.2.2.8 If an obstruction is encountered again the doors shall stop reverse

direction one inch, time out and close.2.5.2.2.9 The doors shall continue recycling at 50 percent until the object is cleared.

2.5.2.3 Door Motion Adjustments: Control digital interface provides means to make the following door adjustments; open high speed, open low speed, open braking force, close high speed, close low speed, close braking force, opening time.

2.5.2.4 Nylon Sweeps:2.5.2.4.1 On bottom of sliding doors.2.5.2.4.2 Double pile weatherstripping for sliding door lead edges.2.5.2.4.3 Single pile weatherstripping between carrier and header on lead stiles of

sidelights and pivot stiles of sliding doors.

2.6 ACCESS CONTROL SLIDE DOOR OPERATORS (DS-18C)

2.6.1 Access Control Slide Door Operators: Model DS-18C with access control devices as manufactured by DITEC Entrematic North America.2.6.1.1 Components: Provide door operating equipment, access control system

components, guide threshold, actuating and safety controls, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

2.6.1.1.1 Acceptable alternative under code standard is 8600 surface mounted panic device.

2.6.1.2 Emergency Breakout System: With an 86F recessed panic device in muntin bar.2.6.1.3 System Design: Components in the header factory engineered, assembled,

adjusted and tested.2.6.1.3.1 Field wiring consists of connection to job-site power and actuators.2.6.1.3.2 The bi-part sliding door system shall include an electric solenoid deadlock

08 71 13-8

Page 9: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

securing the active door carrier assemblies together (in the closed position) or for a single slide an electric solenoid deadlock securing the active door carrier assembly to the vertical closing jamb.

2.6.1.3.3 The electric solenoid lock shall be classified Fail Safe or Fail Secure.2.6.1.3.4 Each door panel shall include interlocking that securely latches the swing

out panel(s) to the sliding panel(s) in the fully closed position.2.6.1.4 Operating Temperature Range: System components shall operate between -70

degrees F and 130 degrees F (-56 degrees C and 54 degrees C).2.6.1.5 Aluminum Extrusion Finish: As scheduled and indicated on Drawings.2.6.1.6 Aluminum Extrusion Finish: Standard, clear anodized.2.6.1.7 Aluminum Extrusion Finish: Standard, bronze anodized.2.6.1.8 Aluminum Extrusion Finish: Standard, light bronze anodized.2.6.1.9 Aluminum Extrusion Finish: Special anodized, color ___________.2.6.1.10 Aluminum Extrusion Finish: Painted, color ___________.2.6.1.11 Aluminum Extrusion Finish: Clad, ___________.2.6.1.12 Door Panels and Sidelights: Sized to prevent pinch points at meeting stiles.

2.6.1.12.1 Compliance: Allow "breakout" to full open position to provide instant egress at any point in door's movement.

2.6.1.12.2 Sliding Aluminum Doors: Narrow stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation; with intermediate rails.

2.6.1.12.3 Door Panels: Include interlocking that securely latches the fully closed position.

2.6.1.12.4 Door Glass Thickness: As scheduled and indicated on Drawings.2.6.1.12.5 Door Glass Thickness: Stops for 1/4 inch (6 mm) glazing.2.6.1.12.6 Door Glass Thickness: Stops for 5/8 inch (16 mm) glazing.2.6.1.12.7 Aluminum Sidelights: Narrow stile through bolted units, to dimensions and

with glazing as scheduled and indicated on Drawings and order confirmation.

2.6.1.12.8 Sidelight Glass Thickness: As scheduled and indicated on Drawings.2.6.1.12.9 Sidelight Glass Thickness: Stops for 1/4 inch (6 mm) glazing.2.6.1.12.10 Sidelight Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

2.6.1.13 Aluminum Frames and Extrusions:2.6.1.13.1 Integral Structural Sections: Minimum .125 inch (3 mm) thickness.2.6.1.13.2 Dimensions: 4-1/2 inches (114 mm) deep x 1-3/4 inches wide (44 mm)

section.2.6.1.13.3 Transom Package: None.2.6.1.13.4 Transom Package: As scheduled and indicated on Drawings.2.6.1.13.5 Transom Package: One vertical transom tube, designed for 1/4 inch (6

mm) glazing.2.6.1.13.6 Transom Package: One vertical transom tube, designed for 1 inch (24 mm)

glazing.2.6.1.14 Header Cases:

2.6.1.14.1 Materials: Extruded aluminum.2.6.1.14.2 Size: 4-1/2 inches wide x 7-1/2 inches high (108 mm x 180 mm).2.6.1.14.3 Capacity: Header shall be capable of supporting a single door leaf of 250

pounds or bi-parting door leaf of 250 pounds each over a span of 18 ft (5.5 m) with deflection within limits established by manufacturer for product application.

2.6.1.14.4 Slide System: Digital slide system and door mounting components.2.6.1.14.5 Header Cover: With a continuous hinge, opens flush with top of header.

2.6.1.15 Door Hanger Wheels:2.6.1.15.1 Materials: Urethane.2.6.1.15.2 Diameter: 2-1/2 inch (64 mm).2.6.1.15.3 Bearings: Precision lifetime lubricated ball bearings.2.6.1.15.4 Anti Riser Blocks: 4 Delrin anti riser block per door, to secure sliding doors

08 71 13-9

Page 10: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

to roller tracks, field replaceable.2.6.1.15.5 Adjustability: Doors can be adjusted down up to 1/2 inch (13 mm).

2.6.1.16 Guide Threshold Track: Guides slide panels from close to open and open to close.

2.6.1.16.1 Materials: Aluminum.2.6.1.16.2 Profiles: As scheduled and indicated on Drawings .2.6.1.16.3 Profiles: Recess mounted.2.6.1.16.4 Profiles: Surface mounted double bevel.2.6.1.16.5 Profiles: Surface mounted combination bevel/square; options are field

adjustable by snap-off beveled edge.2.6.1.17 Drive Systems: Digital Slide System.

2.6.1.17.1 Components: Electromechanical 1/5 hp, 100V, brushless DC motor and enclosed hypoid gear system with maximum opening speed of 750 mm/sec.

2.6.1.17.2 Power Requirements: Provide 120 VAC, 5 amps single-phase power supply minimum to operator transformer junction box within header.

2.6.1.18 Control Units: DS-18C Ferrite Chip Control Unit.2.6.1.18.1 Torque shall be factory set as prescribed by ANSI A156.10.2.6.1.18.2 In the event of power failure active doors maybe opened manually.2.6.1.18.3 Microprocessor Controls: Monitors doorway holding beams, door position,

electric lock position, activators, motor temperature, and condition of power.

2.6.1.18.4 Self-Diagnostics: Checks performed on continuous basis, faults displayed by flashing LED's and buzzer noise on control panels.

2.6.1.19 Doorway Holding Beams:2.6.1.19.1 Factory installed at 24 inches (610 mm) and 48 inches (1219 mm) from

finished floor.2.6.1.19.2 When the beam is interrupted, an open door shall be inhibited from closing.

2.6.1.20 Switches: As scheduled and indicated on Drawings2.6.1.21 Switches: 10 position switch. (10PS)2.6.1.22 Switches: 10 position switch with key. (10PK)2.6.1.23 Switches: 3 position switch. (3PS)2.6.1.24 Switches: 3 position switch with key. (3PK)2.6.1.25 Switches: 4 position switch. (4PS)2.6.1.26 Switches: 4 position switch with key. (4PK)

2.6.2 Operation:2.6.2.1 Motion Detection: Actuated by motion detector mounted on each side of door

detection of traffic in each direction.2.6.2.2 Reverse Function:

2.6.2.2.1 Upon obstruction with Safety Search Circuitry.2.6.2.2.2 Doors shall recycle open if an object is encountered during closing cycle.2.6.2.2.3 Circuitry shall time-out for 5 seconds then search for that object at 50

percent speed on next closing cycle.2.6.2.2.4 If an obstruction is encountered again, doors will recycle open.2.6.2.2.5 Doors shall keep timing-out and recycling at 50 percent speed until

obstruction is cleared.2.6.2.2.6 If an object is encountered while opening, the doors will stop, reverse

direction one inch, time-out for 5 seconds and close at 50 percent speed.2.6.2.2.7 The next opening the circuitry shall search for that object at 50 percent

speed.2.6.2.2.8 If an obstruction is encountered again the doors shall stop reverse

direction one inch, time out and close.2.6.2.2.9 The doors shall continue recycling at 50 percent until the object is cleared.

2.6.2.3 Door Motion Adjustments: Control digital interface provides means to make the following door adjustments; open high speed, open low speed, open braking

08 71 13-10

Page 11: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

force, close high speed, close low speed, close braking force, opening time.2.6.2.4 Nylon Sweeps:

2.6.2.4.1 On bottom of sliding doors.2.6.2.4.2 Double pile weatherstripping for sliding door lead edges.2.6.2.4.3 Single pile weatherstripping between carrier and header on lead stiles of

sidelights and pivot stiles of sliding doors.

2.7 INTENSIVE CARE UNIT MANUAL SLIDING DOOR SYSTEM (IC-18)

2.7.1 Intensive Care Unit Manual Sliding Door System: Model IC-18 ICU Manual Slide as manufactured by DITEC Entrematic North America.2.7.1.1 Components: Provide door operating system, safety devices, accessories and

fasteners as required for complete installation and as scheduled and indicated on Drawings.

2.7.1.2 System Design: Header components are factory engineered, assembled, adjusted and tested.

2.7.1.3 Operating Temperature Range: Between -30 degrees F and 130 degrees F (-34 degrees C to 54 degrees C).

2.7.1.4 Aluminum Extrusion Finish: As scheduled and indicated on Drawings.2.7.1.5 Aluminum Extrusion Finish: Standard, clear anodized.2.7.1.6 Aluminum Extrusion Finish: Standard, bronze anodized.2.7.1.7 Aluminum Extrusion Finish: Standard, light bronze anodized.2.7.1.8 Aluminum Extrusion Finish: Special anodized, color ___________.2.7.1.9 Aluminum Extrusion Finish: Painted, color ___________.2.7.1.10 Aluminum Extrusion Finish: Clad, ___________.2.7.1.11 Door Panels and Sidelights: Sized to prevent pinch points at meeting stiles.

2.7.1.11.1 Compliance: Allow "breakout" to full open position to provide instant egress at any point in door's movement.

2.7.1.11.2 Sliding Aluminum Doors: Narrow or medium stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation.

2.7.1.11.3 Door Panels: As scheduled and indicated on Drawings.2.7.1.11.4 Door Panels: Basic package, 2 panels.2.7.1.11.5 Door Panels: Basic package, 3 panels.2.7.1.11.6 Door Panels: Basic package, 4 panels.2.7.1.11.7 Door Panels: Telescoping package, 3 panels.2.7.1.11.8 Door Panels: Telescoping package, 6 panels.2.7.1.11.9 Door Panels: Custom engineered door packages as indicated on

Drawings.2.7.1.11.10 Door Glass Thickness: As scheduled and indicated on Drawings.2.7.1.11.11 Door Glass Thickness: Stops for 1/4 inch (6 mm) glazing.2.7.1.11.12 Door Glass Thickness: Stops for 5/8 inch (16 mm) glazing.2.7.1.11.13 Aluminum Sidelights: Narrow or medium stile through bolted units, to

dimensions and with glazing as scheduled and indicated on Drawings and order confirmation; with intermediate rails.

2.7.1.11.14 Sidelight Glass Thickness: As scheduled and indicated on Drawings.2.7.1.11.15 Sidelight Glass Thickness: Stops for 1/4 inch (6 mm) glazing.2.7.1.11.16 Sidelight Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

2.7.1.12 Aluminum Frames and Extrusions:2.7.1.12.1 Dimensions: As scheduled and indicated on Drawings.2.7.1.12.2 Dimensions: Basic package, 4-1/2 inches (114 mm) deep x 1-3/4 inches

wide (44 mm) section. with basic package.2.7.1.12.3 Dimensions: Telescoping package, 6 inches (152 mm) deep x 1-3/4 inches

wide (44 mm) section.2.7.1.12.4 Transom Package: None.2.7.1.12.5 Transom Package: As scheduled and indicated on Drawings.

08 71 13-11

Page 12: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

2.7.1.12.6 Transom Package: One vertical transom tube, designed for 1/4 inch (6 mm) glazing.

2.7.1.12.7 Transom Package: One vertical transom tube, designed for 1 inch (24 mm) glazing.

2.7.1.13 Header Cases: Encompass the door track and anti-riser guide.2.7.1.13.1 Materials: Extruded aluminum.2.7.1.13.2 Size: 4-1/2 inches wide x 3-5/8 inches high (114 mm x 92 mm).2.7.1.13.3 Header Cover: With a continuous self-locking hinge, opens flush with top of

header.2.7.1.14 Door Hanger Wheels:

2.7.1.14.1 Wheel Materials: Nylon.2.7.1.14.2 Diameter: 2-1/2 inch (64 mm).2.7.1.14.3 Bearings: Stainless steel lifetime lubricated ball bearings.2.7.1.14.4 Anti Riser Wheels: 2 inch (51 mm) anti-riser wheels and supported by a

factory adjusted cantilever support and pivot assembly.2.7.1.14.5 Adjustability: Door height and anti-rise adjustments shall be fully accessible

with hinge cover in "open" position, field adjustable.2.7.1.15 Static Electric Grounding: Provide doors with static electric grounding.2.7.1.16 Architectural Hardware and Accessories: Provide stops in header to limit door

slide travel.2.7.1.16.1 Handles: As scheduled and indicated on Drawings.2.7.1.16.2 Handles: Standard, recessed door pulls.2.7.1.16.3 Handles: Provide optional surface mounted "D" shaped pull handles.2.7.1.16.4 Handles: Positive latching handles are also optional.2.7.1.16.5 Handle Finish: As scheduled and indicated on Drawings.2.7.1.16.6 Handle Finish: Silver painted finish.2.7.1.16.7 Handle Finish: Flat painted finish.2.7.1.16.8 Weatherstripping: Double vinyl weather stripping on lead stile of the sliding

doors and pivot stile of sidelights.2.7.1.16.9 Floor Track Type: As scheduled and indicated on Drawings .2.7.1.16.10 Floor Track Type: None, trackless (SX), pivot assemblies for trackless

panel applications shall allow the sliding panels to swing outward for emergency egress without the need of a lower pivot support.

2.7.1.16.11 Floor Track Type: Provide floor track to guide sliding door.2.7.1.16.11.1 Materials: Aluminum.2.7.1.16.11.2 Profiles: As scheduled and indicated on Drawings .2.7.1.16.11.3 Profiles: Recess mounted.2.7.1.16.11.4 Profiles: Surface mounted double bevel.2.7.1.16.11.5 Profiles: Surface mounted combination bevel/square; options are

field adjustable by snap-off beveled edge.

2.8 ICU MANUAL FOLD-SWING DOOR SYSTEM (FS-IC)

2.8.1 Intensive Care Unit Manual Fold-Swing Door Systems: Model FS-IC as manufactured by DITEC Entrematic North America.2.8.1.1 Components: Provide door operating system, safety devices, accessories and

fasteners as required for complete installation and as scheduled and indicated on Drawings.

2.8.1.2 System Design: Components in the header factory engineered, assembled, adjusted and tested.

2.8.1.3 Operating Temperature Range: Between -30 degrees F and 130 degrees F (-34 degrees C to 54 degrees C).

2.8.1.4 Aluminum Extrusion Finish: As scheduled and indicated on Drawings.2.8.1.5 Aluminum Extrusion Finish: Standard, clear anodized.2.8.1.6 Aluminum Extrusion Finish: Standard, bronze anodized.2.8.1.7 Aluminum Extrusion Finish: Standard, light bronze anodized.

08 71 13-12

Page 13: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

2.8.1.8 Aluminum Extrusion Finish: Special anodized, color ___________.2.8.1.9 Aluminum Extrusion Finish: Painted, color ___________.2.8.1.10 Aluminum Extrusion Finish: Clad, ___________.2.8.1.11 Fold-Swing Aluminum Doors: Through bolted door units, narrow or medium stile,

to dimensions and with intermediate rails as scheduled and indicated on Drawings.

2.8.1.11.1 Door Glass Thickness: As scheduled and indicated on Drawings.2.8.1.11.2 Door Glass Thickness: Stops for 1/4 inch (6 mm) glazing, with transoms.2.8.1.11.3 Door Glass Thickness: Stops for 5/8 inch (16 mm) glazing.2.8.1.11.4 Size: As scheduled and indicated on Drawings.2.8.1.11.5 Size: 36 inches (914 mm).2.8.1.11.6 Size: 42 inches (1067 mm).2.8.1.11.7 Door Configuration: Shall be either the 2 leaf fold-1 leaf swing basic door

package or the 4 leaf bifolding (no swing) door package.2.8.1.12 Aluminum Frames and Extrusions:

2.8.1.12.1 Integral Structural Sections: Minimum .125 inch (3 mm) thickness.2.8.1.12.2 Dimensions: 4-1/2 inches (114 mm) deep x 1-3/4 inches wide (44 mm)

section.2.8.1.13 Header Cases: Encompass folding door track and swing door concealed closer

device, with removable plate which provides access to pivot components.2.8.1.13.1 Materials: Extruded aluminum.2.8.1.13.2 Size: 4-1/2 inches wide x 2 inches high (114 mm x 51 mm).

2.8.1.14 Pivot Assemblies: Adjustable pivot assemblies shall allow the door panels to fold-swing open for emergency ingress/egress without the need of breakaway devices.

2.8.1.15 Static Electric Grounding, Provide doors with optional static electric grounding.2.8.1.16 Hardware and Accessories:

2.8.1.16.1 Handles: Standard, surface mounted "D" shaped pull handles; pull bars span lead fold panels.

2.8.1.16.2 Handle Finish: As scheduled and indicated on Drawings.2.8.1.16.3 Handle Finish: Silver painted finish.2.8.1.16.4 Handle Finish: Flat painted finish.2.8.1.16.5 Fold Door Guide: 1 inch (25 mm) delrin; free floating through travel of door.2.8.1.16.6 Weatherstripping: Lead and pivot stile of the fold-swing doors shall be

provided with double brushpile or vinyl weather stripping.2.8.1.16.7 Floor Track Type: None, trackless.

2.8.2 Operation:2.8.2.1 Folding leaves shall remain at full open position until manually closed.2.8.2.2 Swing door shall return to closed position automatically by concealed double

acting door closer unless opened to (90 degree) full open maintained position.2.8.2.3 Swing door manually moved from full open position towards closure shall

continue to closed position automatically.

2.9 HARDWARE AND ACCESSORlES

2.9.1 Activation and Safety Devices:2.9.1.1 Push Plates: Standard.2.9.1.2 Push Plates: BEA Push Plates.2.9.1.3 Semi Automatic Sliding Door Systems: HSC Remote Control System.2.9.1.4 Semi Automatic Sliding Door Systems: HCA Remote Control System.2.9.1.5 Microwave Sensors: BEA.2.9.1.6 Microwave Sensors: Optex.2.9.1.7 Safety Sensors: BEA.2.9.1.8 Safety Sensors: Optex.

08 71 13-13

Page 14: ARCAT · Web viewSection 26 05 19 - Low-Voltage Electrical Power Conductors and Cables. REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are …

2.9.2 Locking Systems: As scheduled and indicated on Drawings.

2.9.3 Locking Systems: Trident 4 point lock, 4-point deadbolt exit lock (3 moving, fixed hinge-side bolt); depressing paddle retracts deadbolts for one-motion exiting.

2.9.4 Locking Systems: TEL-100, locked by pulling paddle when door is in closed position.

2.9.5 Locking Systems: TEL-200 models provide identical deadbolt protection, with self re-locking each time door is closed; pull handle is not furnished, door closer is required for self-locking.

3 EXECUTION

3.1 EXAMINATION AND PREPARATION

3.1.1 Prepare substrates using the methods recommended by the manufacturer for achieving best result for the substrates under project conditions.

3.1.2 Field verify as-built conditions and verify the manufacturer's details for accuracy to fit the wall assembly prior to fabrication.

3.1.3 Do not proceed with installation until substrates have been prepared using the methods recommended by the manufacturer and deviations from manufacturer's recommended tolerances are corrected. Commencement of installation constitutes acceptance of conditions.

3.1.4 If preparation is the responsibility of another installer, notify Architect in writing of deviations from manufacturer's recommended installation tolerances and conditions.

3.2 INSTALLATION

3.2.1 Install in accordance with manufacturer's instructions. Set units in proper relationship with adjacent work. Test for proper operation and adjust until satisfactory results are obtained3.2.1.1 Installation shall be approved by an AAADM certified inspector.3.2.1.2 Conform to UL Standard 325 and ANSI-BHMA Standard A156.103.2.1.3 Conform to UL Standard 325 and ANSI-BHMA Standard A156.19.3.2.1.4 Explain and review the Daily Safety Check Procedure.

3.3 PROTECTION

3.3.1 Protect installed products until completion of project.

3.3.2 Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION

08 71 13-14