1
3580 583 3580 583 1 2 3 1a 2a 3454 8000 8000 8000 8000 8000 8000 8000 2059 5513 8000 6688 8000 328 10552 1635 6360 1675 2150 4900 3100 3580 583 3580 583 75.026 between cladding rails 102.360 between grid and cladding rail line of plant deck over 2646 813 A A B B C D E F G H J K L L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1a 2a C1 D1 E1 F1 G1 H1 J1 K1 3454 8000 8000 8000 8000 8000 8000 8000 2059 5513 8000 6688 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 5513 8000 8000 8000 8000 8000 8000 8000 8000 5513 328 10552 1635 6360 1675 B1 2150 4900 3100 207 01 GROUND FLOOR PLAN 1:250 FWC DIS. WC LIFT STAIR 1 MWC CL SHW RECEPTION UNIT 3 STAIR 2 207 02 FIRST FLOOR PLAN 1:250 FWC DIS. WC LIFT STAIR 1 MWC CL SHW VOID OPEN PLAN OFFICE STAIR 2 TP TP 03 207 KEY PLAN LOCATION OF UNITS NTS HEATHROW LOGISTICS PARK UNIT 3 FLOOR PLANS BLACKROCK & GRAFTONGATE JAN 2016 1:250 @ A1 NSC AS BUILT MS 30639-RE-207G 1 2 3 4 DG 16 DG 17 DG 18 DG 19 DG 20 DG 21 DG 22 DG 23 DG 24 LD 01 LD 02 LD 03 LD 04 LD 05 LD 06 LD 07 LD 08 LD 09 LD 10 ENSURE SEALING OF ALL JUNCTIONS TO COMPLY WITH PART L. NOTES: SUBJECT TO STATUTORY CONSENTS SUBJECT TO SURVEY BASED ON OS MAP REPRODUCED BY PERMISSION OF CONTROLLER OF HM STATIONARY OFFICE (c) CROWN COPYRIGHT COPYRIGHT RESERVED DO NOT SCALE THIS DRAWING DO NOT USE ELECTRONIC VERSIONS OF THIS DRAWING TO DETERMINE DIMENSIONS UNLESS SPECIFICALLY AUTHORISED BY MICHAEL SPARKS ASSOCIATES IF USING AN ELECTRONIC VERSION OF THIS DRAWING FIGURED DIMENSIONS TAKE PRECEDENCE AND NOTIFY MICHAEL SPARKS ASSOCIATES OF ANY DISCREPANCIES PROVIDE ONE HOUR FIRE PROTECTION TO UPPER FLOORS CONSTRUCTION AND ONE HOUR FIRE PROTECTION TO SUPPORTING STRUCTURE. COMPLY WITH ALL PARTS OF APPROVED DOCUMENTS IN PARTICULAR PART B, PART L2 AND PART M. ALL DIMENSIONS TO BE CHECKED ON SITE. STEEL COLUMN SIZES TO BE CONFIRMED AND TOLERANCES TO BE AGREED. NOTE: ROOF AND WALL CLADDING TO BE DESIGNED BY SPECIALIST CONTRACTOR. CLADDING DETAILS TO BE READ IN CONJUNCTION WITH THE SPECIFICATION AND ALL RELEVANT BRITISH STANDARDS. INCLUDE VAPOUR BARRIER TAPE AROUND ALL OPENINGS AND JUNCTIONS. U-Values :PðN Roof: 0.18 Ground Floors: 0.22 Walls: 0.24 Glazing: 1.73 /0.43 Rooflights: 1.3 / 0.55 Entrance Door: 1.5 Loading Door: 1.49 TENDER line of brise soleil over THIS "AS-BUILT" DRAWING IS BASED ON INFORMATION SUPPLIED TO MICHAEL SPARKS ASSOCIATES BY READIE CONSTRUCTION AND INCORPORATES INSTRUCTIONS AND OTHER DESIGN INFORMATION GIVEN TO READIE CONSTRUCTION DIRECTLY BY OTHERS AS BUILT

AS BUILT - Heathrow Logistics Park€¦ · ALL OPENINGS AND JUNCTIONS. U-Values : PðN Roof: 0.18 Ground Floors: 0.22 Walls: 0.24 Glazing: 1.73 /0.43 Rooflights: 1.3 / 0.55 Entrance

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AS BUILT - Heathrow Logistics Park€¦ · ALL OPENINGS AND JUNCTIONS. U-Values : PðN Roof: 0.18 Ground Floors: 0.22 Walls: 0.24 Glazing: 1.73 /0.43 Rooflights: 1.3 / 0.55 Entrance

3580

583

3580

583

1 2 3

1a 2a

34

54

80

00

80

00

80

00

80

00

80

00

80

00

80

00

20

59

55

13

80

00

6688 8000

328

10552

1635 636016

75

2150

49

00

31

00

358058

33580

583

75

.0

26

b

etw

ee

n cla

dd

in

g ra

ils

102.360 between grid and cladding rail

line of plant deck over

2646

813

AA

BB

C

D

E

F

G

H

J

K

LL

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1a 2a

C1

D1

E1

F1

G1

H1

J1

K1

34

54

80

00

80

00

80

00

80

00

80

00

80

00

80

00

20

59

55

13

80

00

6688 8000 8000 80008000 80008000 8000 8000 80008000 80008000

55

13

80

00

80

00

80

00

80

00

80

00

80

00

80

00

80

00

55

13

328

10552

1635 636016

75

B1

2150

49

00

31

00

207

01

GROUND FLOOR PLAN

1:250

FWC

DIS.

WC

LIFT

STAIR 1

MWC

CL

SHW

RECEPTION

UNIT 3

STAIR 2

207

02

FIRST FLOOR PLAN

1:250

FWC

DIS.

WC

LIFT

STAIR 1

MWC

CL

SHW

VOID

OPEN PLAN OFFICE

STAIR 2

TP

TP

03

207

KEY PLAN

LOCATION OF UNITS

NTS

HEATHROW LOGISTICS PARK

UNIT 3 FLOOR PLANS

BLACKROCK & GRAFTONGATE

JAN 2016 1:250 @ A1 NSC

AS BUILT

MS

30639-RE-207G

1

2

3

4

DG 16

DG 17

DG 18 DG 19

DG 20

DG 21

DG 22

DG 23

DG 24

LD 01

LD 02 LD 03 LD 04 LD 05 LD 06LD 07 LD 08 LD 09

LD 10

ENSURE SEALING OF ALL JUNCTIONS TO COMPLY WITH PART L.

NOTES:

SUBJECT TO STATUTORY CONSENTS

SUBJECT TO SURVEY

BASED ON OS MAP REPRODUCED BY PERMISSION OF

CONTROLLER OF HM STATIONARY OFFICE (c) CROWN

COPYRIGHT

COPYRIGHT RESERVED

DO NOT SCALE THIS DRAWING

DO NOT USE ELECTRONIC VERSIONS OF THIS DRAWING TO

DETERMINE DIMENSIONS UNLESS SPECIFICALLY

AUTHORISED BY MICHAEL SPARKS ASSOCIATES

IF USING AN ELECTRONIC VERSION OF THIS DRAWING

FIGURED DIMENSIONS TAKE PRECEDENCE AND NOTIFY

MICHAEL SPARKS ASSOCIATES OF ANY DISCREPANCIES

PROVIDE ONE HOUR FIRE PROTECTION TO UPPER

FLOORS CONSTRUCTION AND ONE HOUR FIRE

PROTECTION

TO SUPPORTING STRUCTURE.

COMPLY WITH ALL PARTS OF APPROVED DOCUMENTS

IN PARTICULAR PART B, PART L2 AND PART M.

ALL DIMENSIONS TO BE CHECKED ON SITE.

STEEL COLUMN SIZES TO BE CONFIRMED AND TOLERANCES TO BE AGREED.

NOTE:

ROOF AND WALL CLADDING TO BE DESIGNED

BY SPECIALIST CONTRACTOR.

CLADDING DETAILS TO BE READ IN CONJUNCTION

WITH THE SPECIFICATION AND ALL RELEVANT

BRITISH STANDARDS.

INCLUDE VAPOUR BARRIER TAPE AROUND

ALL OPENINGS AND JUNCTIONS.

U-Values W/m²k

Roof: 0.18

Ground Floors: 0.22

Walls: 0.24

Glazing: 1.73 /0.43

Rooflights: 1.3 / 0.55

Entrance Door: 1.5

Loading Door: 1.49

TENDER

line of brise soleil over

THIS "AS-BUILT" DRAWING IS BASED ON INFORMATION

SUPPLIED TO MICHAEL SPARKS ASSOCIATES BY READIE

CONSTRUCTION AND INCORPORATES INSTRUCTIONS AND

OTHER DESIGN INFORMATION GIVEN TO READIE

CONSTRUCTION DIRECTLY BY OTHERS

AS BUILT