Transcript
Page 1: AS BUILT - Heathrow Logistics Park€¦ · ALL OPENINGS AND JUNCTIONS. U-Values : PðN Roof: 0.18 Ground Floors: 0.22 Walls: 0.24 Glazing: 1.73 /0.43 Rooflights: 1.3 / 0.55 Entrance

3580

583

3580

583

1 2 3

1a 2a

34

54

80

00

80

00

80

00

80

00

80

00

80

00

80

00

20

59

55

13

80

00

6688 8000

328

10552

1635 636016

75

2150

49

00

31

00

358058

33580

583

75

.0

26

b

etw

ee

n cla

dd

in

g ra

ils

102.360 between grid and cladding rail

line of plant deck over

2646

813

AA

BB

C

D

E

F

G

H

J

K

LL

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1a 2a

C1

D1

E1

F1

G1

H1

J1

K1

34

54

80

00

80

00

80

00

80

00

80

00

80

00

80

00

20

59

55

13

80

00

6688 8000 8000 80008000 80008000 8000 8000 80008000 80008000

55

13

80

00

80

00

80

00

80

00

80

00

80

00

80

00

80

00

55

13

328

10552

1635 636016

75

B1

2150

49

00

31

00

207

01

GROUND FLOOR PLAN

1:250

FWC

DIS.

WC

LIFT

STAIR 1

MWC

CL

SHW

RECEPTION

UNIT 3

STAIR 2

207

02

FIRST FLOOR PLAN

1:250

FWC

DIS.

WC

LIFT

STAIR 1

MWC

CL

SHW

VOID

OPEN PLAN OFFICE

STAIR 2

TP

TP

03

207

KEY PLAN

LOCATION OF UNITS

NTS

HEATHROW LOGISTICS PARK

UNIT 3 FLOOR PLANS

BLACKROCK & GRAFTONGATE

JAN 2016 1:250 @ A1 NSC

AS BUILT

MS

30639-RE-207G

1

2

3

4

DG 16

DG 17

DG 18 DG 19

DG 20

DG 21

DG 22

DG 23

DG 24

LD 01

LD 02 LD 03 LD 04 LD 05 LD 06LD 07 LD 08 LD 09

LD 10

ENSURE SEALING OF ALL JUNCTIONS TO COMPLY WITH PART L.

NOTES:

SUBJECT TO STATUTORY CONSENTS

SUBJECT TO SURVEY

BASED ON OS MAP REPRODUCED BY PERMISSION OF

CONTROLLER OF HM STATIONARY OFFICE (c) CROWN

COPYRIGHT

COPYRIGHT RESERVED

DO NOT SCALE THIS DRAWING

DO NOT USE ELECTRONIC VERSIONS OF THIS DRAWING TO

DETERMINE DIMENSIONS UNLESS SPECIFICALLY

AUTHORISED BY MICHAEL SPARKS ASSOCIATES

IF USING AN ELECTRONIC VERSION OF THIS DRAWING

FIGURED DIMENSIONS TAKE PRECEDENCE AND NOTIFY

MICHAEL SPARKS ASSOCIATES OF ANY DISCREPANCIES

PROVIDE ONE HOUR FIRE PROTECTION TO UPPER

FLOORS CONSTRUCTION AND ONE HOUR FIRE

PROTECTION

TO SUPPORTING STRUCTURE.

COMPLY WITH ALL PARTS OF APPROVED DOCUMENTS

IN PARTICULAR PART B, PART L2 AND PART M.

ALL DIMENSIONS TO BE CHECKED ON SITE.

STEEL COLUMN SIZES TO BE CONFIRMED AND TOLERANCES TO BE AGREED.

NOTE:

ROOF AND WALL CLADDING TO BE DESIGNED

BY SPECIALIST CONTRACTOR.

CLADDING DETAILS TO BE READ IN CONJUNCTION

WITH THE SPECIFICATION AND ALL RELEVANT

BRITISH STANDARDS.

INCLUDE VAPOUR BARRIER TAPE AROUND

ALL OPENINGS AND JUNCTIONS.

U-Values W/m²k

Roof: 0.18

Ground Floors: 0.22

Walls: 0.24

Glazing: 1.73 /0.43

Rooflights: 1.3 / 0.55

Entrance Door: 1.5

Loading Door: 1.49

TENDER

line of brise soleil over

THIS "AS-BUILT" DRAWING IS BASED ON INFORMATION

SUPPLIED TO MICHAEL SPARKS ASSOCIATES BY READIE

CONSTRUCTION AND INCORPORATES INSTRUCTIONS AND

OTHER DESIGN INFORMATION GIVEN TO READIE

CONSTRUCTION DIRECTLY BY OTHERS

AS BUILT

Recommended