64
Ascotherm ® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change. Ascotherm eco KC481 Tender specification, range available and sizes Operating principle Forced convection for heating Cold air from the window areas and cooled air are drawn in and trans- ported through the heat exchanger. Heated air rises. Installation in front of window areas provides a specific shielding against cold air. For more information, see chapter "General information" Forced convection for cooling Warmed air is drawn in, cooled in the register and discharged into the room as cool air. Installation in front of window areas provides a specific shielding against the thermal radiation due to inci- dent solar radiation. For more information, see chapter "General information". Tender specification Version KC481 heating and cooling in 4-conductor system Ready-to-install floor pans for the floor area. Operating prin- ciple: Forced convection with a cross-flow fan for heating and cooling in a 4-conductor system. Sturdy floor pan made of galvanised sheet steel, coloured in anthracite grey (RAL 7016), external, adjustable and acoustically decoupled height adjustments (pre-installed). Condensate pan integrated into floor pan, incl. two drain connections (Ø 15 mm) on the sides. Register made of copper pipes and aluminium fins, anthracite grey (RAL7016) coated and mounted in transversal steel girder of galvanised sheet steel, acoustically decoupled. Cooling: Standard left to the face or room side connection with euro taper and union nut ( 3 / 4 “ internal thread) and air vent. Heating: Standard right to the face or room side connection with euro taper and union nut ( 3 / 4 “ internal thread) and air vent. Suitable for a max. operating pressure of 10 bar (optional- ly 16 bar) and a max. operating temperature of 90 °C. Cross-flow fan already installed in the floor pan parallel to the heat register (cross-flow fan on the window side). Protective cover over the cross-flow fan. Cross-flow fan with energy-saving EC motors 24 V, wired ready for connection. Low-noise fan operation, infinitely variable via analogue interface (0 – 10 V). Actuator control signal 24 V DC, infinitely variable via analogue interface (0 – 10 V). Synchronised control of fan speed and water flow for a hydraulically balanced pipe system and especially energy-efficient operation while maintai- ning a minimum spread between flow and return temperature. Factory configuration of appropriate control algorithm. Aluminium roll-up grille as standard. Acoustic decoupling through placement of the aluminium roll-up grille on rubber elements in the floor pan. Consisting of sturdy lengthwise pro- file bars, natural colour anodised, with profile bar dimensions of 20 x 6 mm. .Grille with a total height of 20 mm and an open cross-section of 70%. Including installation cover and edge bar protection for protec- tion of the trench convectors during the construction phase. QA system certified to DIN EN ISO 9001:2008. Environmental management system to DIN EN ISO 14001:2004. Operating conditions: Hot water up to 90 °C Operating pressure: Max. 10 bar (optionally 16 bar high-pres- sure-version) Test pressure: 13 bar (21 bar) General Trench convectors find application in private residential areas, in conservatories, in offices and administration buildings, in show- rooms as well as in business areas. Version KC481 heating and cooling in 4-conductor system Heating connections right: 2 x euro taper with union nut ( 3 / 4 “ internal thread), suitable for use with all fittings that comply with DIN V 3838 Cooling connections left: 2 x euro tape with union nut ( 3 / 4 “ internal thread), suitable for use with all fittings that comply with DIN V 3838 Air vent: installed Range available 2 depths: 330 and 360 mm 2 heights: 130 and 155 mm 3 lengths: 1250, 2000 and 2750 mm Standard: Aluminium roll-up grille Surface finishes Standard colour of floor pan, powder-coated: Anthracite grey (RAL7016 matt finish) Standard colour of roll-up grille: Aluminium anodised in natural colour Standard colour of edge bar correspond to the colour of top grille Accessories Programmable room thermostat Thermoelectric actuator 24 V AC Connection set, consisting of valve base with factory preset k V valve and return fitting with shut-off Air-intake filter For additional accessories and information, see "Accessories".

Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

50 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

KC4

81

Tender specification, range available and sizes

Operating principle

Forced convection for heating

Cold air from the window areas and

cooled air are drawn in and trans-

ported through the heat exchanger.

Heated air rises. Installation in front

of window areas provides a specific

shielding against cold air.

For more information, see chapter

"General information"

Forced convection for cooling

Warmed air is drawn in, cooled in

the register and discharged into the

room as cool air.

Installation in front of window areas

provides a specific shielding against

the thermal radiation due to inci-

dent solar radiation.

For more information, see chapter

"General information".

Tender specification

Version KC481 heating and cooling in 4-conductor system

Ready-to-install floor pans for the floor area. Operating prin-

ciple: Forced convection with a cross-flow fan for heating and

cooling in a 4-conductor system.

Sturdy floor pan made of galvanised sheet steel, coloured in

anthracite grey (RAL 7016), external, adjustable and acoustically

decoupled height adjustments (pre-installed). Condensate pan

integrated into floor pan, incl. two drain connections (Ø 15 mm)

on the sides.

Register made of copper pipes and aluminium fins, anthracite

grey (RAL7016) coated and mounted in transversal steel girder

of galvanised sheet steel, acoustically decoupled.

Cooling: Standard left to the face or room side connection with

euro taper and union nut (3/4“ internal thread) and air vent.

Heating: Standard right to the face or room side connection

with euro taper and union nut (3/4“ internal thread) and air

vent. Suitable for a max. operating pressure of 10 bar (optional-

ly 16 bar) and a max. operating temperature of 90 °C.

Cross-flow fan already installed in the floor pan parallel to the

heat register (cross-flow fan on the window side). Protective

cover over the cross-flow fan. Cross-flow fan with energy-saving

EC motors 24 V, wired ready for connection.

Low-noise fan operation, infinitely variable via analogue

interface (0 – 10 V). Actuator control signal 24 V DC, infinitely

variable via analogue interface (0 – 10 V). Synchronised control

of fan speed and water flow for a hydraulically balanced pipe

system and especially energy-efficient operation while maintai-

ning a minimum spread between flow and return temperature.

Factory configuration of appropriate control algorithm.

Aluminium roll-up grille as standard. Acoustic decoupling

through placement of the aluminium roll-up grille on rubber

elements in the floor pan. Consisting of sturdy lengthwise pro-

file bars, natural colour anodised, with profile bar dimensions

of 20 x 6 mm. .Grille with a total height of 20 mm and an open

cross-section of 70%.

Including installation cover and edge bar protection for protec-

tion of the trench convectors during the construction phase.

QA system certified to DIN EN ISO 9001:2008.

Environmental management system to DIN EN ISO 14001:2004.

Operating conditions: Hot water up to 90 °C

Operating pressure: Max. 10 bar (optionally 16 bar high-pres-

sure-version)

Test pressure: 13 bar (21 bar)

GeneralTrench convectors find application in private residential areas, in

conservatories, in offices and administration buildings, in show-

rooms as well as in business areas.

Version KC481 heating and cooling in 4-conductor system

• Heating connections right:

2 x euro taper with union nut (3/4“ internal thread), suitable

for use with all fittings that comply with DIN V 3838

• Cooling connections left:

2 x euro tape with union nut (3/4“ internal thread), suitable

for use with all fittings that comply with DIN V 3838

• Air vent: installed

Range available• 2 depths: 330 and 360 mm

• 2 heights: 130 and 155 mm

• 3 lengths: 1250, 2000 and 2750 mm

• Standard: Aluminium roll-up grille

Surface finishes• Standard colour of floor pan, powder-coated:

Anthracite grey (RAL7016 matt finish)

• Standard colour of roll-up grille:

Aluminium anodised in natural colour

• Standard colour of edge bar correspond to the colour of top

grille

Accessories• Programmable room thermostat

• Thermoelectric actuator 24 V AC

• Connection set, consisting of valve base with factory preset kV

valve and return fitting with shut-off

• Air-intake filter

For additional accessories and information, see "Accessories".

Page 2: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 51

Asc

othe

rm e

co

KC4

81

Technical data

Technical dataHeight 130 mm (length 1250 mm)

Length

L[mm]

Depth

T[mm]

Controlvoltage

EC motor[V]

Soundpres-

surelevel

LP

[dB/A]

Acousticpower

levelLW

[dB/A]

Cooling capacity

Standardwaterflow

rateqms

[kg/h]

Expo-

nentn

[ ]

MassM

[kg]

PK ∆T 8 K18/20/27°C

[watts]

PS ∆T 8 K

18/20/27°C[watts]

PKN ∆T 10 K16/18/27°C

[watts]

PSN ∆T 10 K

16/18/27°C[watts]

PK ∆T 12 K12/16/26°C

[watts]

PS ∆T 12 K

12/16/26°C[watts]

PK ∆T 15 K8/14/26°C

[watts]

PS ∆T 15 K

8/14/26°C[watts]

1250

330

3

5

7

10

24

34

42

48

32

42

50

56

217

217

306

306

383

383

439

439

258

258

383

383

469

469

546

546

295

295

457

457

550

550

648

648

348

238

569

458

669

594

801

801

110,3

163,7

200,4

233,3

0,76

1,00

0,90

0,97

16,98

360

3

5

7

10

24

34

42

48

32

42

50

56

239

239

409

409

497

497

552

552

286

286

515

515

611

611

684

684

329

329

616

616

719

719

809

809

391

267

771

620

879

780

996

996

122,2

220,1

261,1

292,3

0,79

1,02

0,92

0,95

17,96

Total standard cooling capacity PKN and sensible standard cooling capacity PSN at ∆T 10 K

Relative humidity 50%

Length

L[mm]

Depth

T[mm]

Controlvoltage

EC motor[V]

Soundpres-surelevel

LP

[dB/A]

Acousticpowerlevel

LW

[dB/A]

Heat outputStandard

waterflow rate

qms

[kg/h]

Expo-nent

n [ ]

Mass

M[kg]

ΦL ∆T 50K

75/65/20°C[watts]

Φ ∆T 42K

70/55/20°C[watts]

Φ ∆T 30K

55/45/20°C[watts]

Φ ∆T 25K

50/40/20°C[watts]

1250

330

0

3

5

7

10

24

34

42

48

32

42

50

56

154

1135

2001

2242

2578

122

958

1689

1892

2176

77

677

1193

1337

1538

60

562

990

1110

1276

13,3

97,8

172,5

193,3

222,2

1,35

1,00

1,00

1,00

1,00

16,98

360

0

3

5

7

10

24

34

42

48

32

42

50

56

169

1403

2493

2855

3261

133

1184

2104

2409

2752

82

837

1487

1703

1945

64

694

1234

1413

1614

14,6

120,9

214,9

246,1

281,1

1,39

1,00

1,00

1,00

1,00

17,96

For individual calculations of heat outputs, see "General Information"

Page 3: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

52 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

KC4

81

Technical data

Technical dataHeight 130 mm (length 2000 mm)

Length

L[mm]

Depth

T[mm]

Controlvoltage

EC motor[V]

Soundpres-

surelevel

LP

[dB/A]

Acousticpower

levelLW

[dB/A]

Cooling capacity

Standardwaterflow

rateqms

[kg/h]

Expo-

nentn

[ ]

MassM

[kg]

PK ∆T 8 K18/20/27°C

[watts]

PS ∆T 8 K

18/20/27°C[watts]

PKN ∆T 10 K16/18/27°C

[watts]

PSN ∆T 10 K

16/18/27°C[watts]

PK ∆T 12 K12/16/26°C

[watts]

PS ∆T 12 K

12/16/26°C[watts]

PK ∆T 15 K8/14/26°C

[watts]

PS ∆T 15 K

8/14/26°C[watts]

2000

330

3

5

7

10

25

36

44

50

33

44

52

58

435

435

612

612

766

766

878

878

516

516

766

766

938

938

1092

1092

590

590

914

914

1099

1099

1296

1296

697

476

1137

915

1339

1188

1602

1602

220,5

327,4

400,9

466,7

0,76

1,00

0,90

0,97

28,55

360

3

5

7

10

25

36

44

50

33

44

52

58

479

479

819

819

993

993

1105

1105

572

572

1030

1030

1222

1222

1368

1368

657

657

1233

1233

1437

1437

1617

1617

782

534

1541

1240

1758

1560

1991

1991

244,4

440,2

522,2

584,6

0,79

1,02

0,92

0,95

30,14

Total standard cooling capacity PKN and sensible standard cooling capacity PSN at ∆T 10 K

Relative humidity 50%

LengthL

[mm]

DepthT

[mm]

Controlvoltage

EC motor

[V]

Sound

pres-

surelevel

LP

[dB/A]

Acoustic

powerlevelLW

[dB/A]

Heat outputStandard

water

flow rateqms

[kg/h]

Expo-nent

n

[ ]

MassM

[kg]

ΦL ∆T 50K

75/65/20°C[watts]

Φ ∆T 42K

70/55/20°C[watts]

Φ ∆T 30K

55/45/20°C[watts]

Φ ∆T 25K

50/40/20°C[watts]

2000

330

0

3

5

7

10

25

36

44

50

33

44

52

58

308

2269

4002

4484

5156

245

1915

3377

3784

4351

153

1353

2387

2674

3075

119

1123

1981

2219

2552

26,6

195,6

345,0

386,6

444,5

1,35

1,00

1,00

1,00

1,00

28,55

360

0

3

5

7

10

25

36

44

50

33

44

52

58

339

2806

4986

5710

6522

268

2368

4208

4819

5504

165

1673

2974

3405

3890

128

1389

2468

2826

3228

29,2

241,9

429,8

492,2

562,2

1,39

1,00

1,00

1,00

1,00

30,14

For individual calculations of heat outputs, see "General Information"

Page 4: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 53

Asc

othe

rm e

co

KC4

81

Technical data

Technical dataHeight 130 mm (length 2750 mm)

Length

L[mm]

Depth

T[mm]

Controlvoltage

EC motor[V]

Soundpres-

surelevel

LP

[dB/A]

Acousticpower

levelLW

[dB/A]

Cooling capacity

Standardwaterflow

rateqms

[kg/h]

Expo-

nentn

[ ]

MassM

[kg]

PK ∆T 8 K18/20/27°C

[watts]

PS ∆T 8 K

18/20/27°C[watts]

PKN ∆T 10 K16/18/27°C

[watts]

PSN ∆T 10 K

16/18/27°C[watts]

PK ∆T 12 K12/16/26°C

[watts]

PS ∆T 12 K

12/16/26°C[watts]

PK ∆T 15 K8/14/26°C

[watts]

PS ∆T 15 K

8/14/26°C[watts]

2750

330

3

5

7

10

26

38

45

51

34

46

53

59

652

652

917

917

1149

1149

1317

1317

774

774

1149

1149

1407

1407

1638

1638

885

885

1371

1371

1649

1649

1943

1943

1045

714

1706

1373

2008

1782

2403

2403

330,8

491,0

601,3

700,0

0,76

1,00

0,90

0,97

41,34

360

3

5

7

10

26

38

45

51

34

46

53

59

718

718

1228

1228

1490

1490

1657

1657

858

858

1545

1545

1833

1833

2052

2052

986

986

1849

1849

2156

2156

2426

2426

1172

800

2312

1860

2637

2340

2987

2987

366,7

660,3

783,3

876,9

0,79

1,02

0,92

0,95

43,54

Total standard cooling capacity PKN and sensible standard cooling capacity PSN AT ∆T 10 K

Relative humidity 50%

LengthL

[mm]

DepthT

[mm]

Controlvoltage

EC motor

[V]

Sound

pres-

surelevel

LP

[dB/A]

Acoustic

powerlevelLW

[dB/A]

Heat outputStandard

water

flow rateqms

[kg/h]

Expo-nent

n

[ ]

MassM

[kg]

ΦL ∆T 50K

75/65/20°C[watts]

Φ ∆T 42K

70/55/20°C[watts]

Φ ∆T 30K

55/45/20°C[watts]

Φ ∆T 25K

50/40/20°C[watts]

2750

330

0

3

5

7

10

26

38

45

51

34

46

53

59

462

3404

6003

6726

7734

367

2873

5066

5676

6527

230

2030

3580

4011

4613

179

1685

2971

3329

3828

39,8

293,4

517,5

579,8

666,7

1,35

1,00

1,00

1,00

1,00

41,34

360

0

3

5

7

10

26

38

45

51

34

46

53

59

508

4209

7479

8565

9783

401

3552

6312

7228

8256

248

2510

4460

5108

5835

191

2083

3701

4239

4842

43,8

362,8

644,7

738,3

843,4

1,39

1,00

1,00

1,00

1,00

43,54

For individual calculations of heat outputs, see "General Information"

Page 5: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

54 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

KC4

81

Technical data

Technical dataHeight 155 mm (length 1250 mm)

Length

L[mm]

Depth

T[mm]

Controlvoltage

EC motor[V]

Soundpres-

surelevel

LP

[dB/A]

Acousticpower

levelLW

[dB/A]

Cooling capacity

Standardwaterflow

rateqms

[kg/h]

Expo-

nentn

[ ]

MassM

[kg]

PK ∆T 8 K18/20/27°C

[watts]

PS ∆T 8 K

18/20/27°C[watts]

PKN ∆T 10 K16/18/27°C

[watts]

PSN ∆T 10 K

16/18/27°C[watts]

PK ∆T 12 K12/16/26°C

[watts]

PS ∆T 12 K

12/16/26°C[watts]

PK ∆T 15 K8/14/26°C

[watts]

PS ∆T 15 K

8/14/26°C[watts]

1250

330

3

5

7

10

25

36

43

49

33

44

51

57

232

232

345

345

385

385

461

461

273

273

442

442

472

472

585

585

310

310

537

537

553

553

705

705

363

248

683

550

674

598

889

889

116,7

188,9

201,7

250,0

0,72

1,10

0,90

1,06

18,24

360

3

5

7

10

25

36

43

49

33

44

51

57

240

240

411

411

496

496

571

571

289

289

537

537

621

621

704

704

335

335

662

662

741

741

829

829

401

274

859

691

922

818

1017

1017

123,5

229,5

265,4

300,9

0,83

1,19

1,00

0,93

19,23

Total standard cooling capacity PKN and sensible standard cooling capacity PSN AT ∆T 10 K

Relative humidity 50%

LengthL

[mm]

DepthT

[mm]

Controlvoltage

EC motor

[V]

Sound

pres-

surelevel

LP

[dB/A]

Acoustic

powerlevelLW

[dB/A]

Heat outputStandard

water

flow rateqms

[kg/h]

Expo-nent

n

[ ]

MassM

[kg]

ΦL ∆T 50K

75/65/20°C[watts]

Φ ∆T 42K

70/55/20°C[watts]

Φ ∆T 30K

55/45/20°C[watts]

Φ ∆T 25K

50/40/20°C[watts]

1250

330

0

3

5

7

10

25

36

43

49

33

44

51

57

158

1264

2130

2388

2727

125

1067

1798

2015

2301

77

754

1270

1424

1626

60

626

1054

1182

1350

13,6

108,9

183,6

205,8

235,1

1,38

1,00

1,00

1,00

1,00

18,24

360

0

3

5

7

10

25

36

43

49

33

44

51

57

191

1440

2542

2926

3294

151

1215

2145

2469

2780

93

859

1516

1745

1965

71

713

1258

1448

1630

16,5

124,1

212,8

244,9

275,7

1,40

1,00

1,00

1,00

1,00

19,23

For individual calculations of heat outputs, see "General Information"

Page 6: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 55

Asc

othe

rm e

co

KC4

81

Technical data

Technical dataHeight 155 mm (length 2000 mm)

Length

L[mm]

Depth

T[mm]

Controlvoltage

EC motor[V]

Soundpres-

surelevel

LP

[dB/A]

Acousticpower

levelLW

[dB/A]

Cooling capacity

Standardwaterflow

rateqms

[kg/h]

Expo-

nentn

[ ]

MassM

[kg]

PK ∆T 8 K18/20/27°C

[watts]

PS ∆T 8 K

18/20/27°C[watts]

PKN ∆T 10 K16/18/27°C

[watts]

PSN ∆T 10 K

16/18/27°C[watts]

PK ∆T 12 K12/16/26°C

[watts]

PS ∆T 12 K

12/16/26°C[watts]

PK ∆T 15 K8/14/26°C

[watts]

PS ∆T 15 K

8/14/26°C[watts]

2000

330

3

5

7

10

27

38

45

51

35

46

53

59

464

464

690

690

771

771

922

922

546

546

884

884

944

944

1170

1170

620

620

1073

1073

1106

1106

1410

1410

726

496

1365

1098

1347

1195

1779

1779

233,3

377,8

403,4

500,0

0,72

1,10

0,90

1,06

30,84

360

3

5

7

10

27

38

45

51

35

46

53

59

480

480

822

822

992

992

1142

1142

578

578

1074

1074

1242

1242

1408

1408

669

669

1325

1325

1481

1481

1659

1659

802

548

1719

1383

1844

1637

2033

2033

247,0

459,0

530,8

601,7

0,83

1,19

1,00

0,93

32,42

Total standard cooling capacity PKN and sensible standard cooling capacity PSN AT ∆T 10 K

Relative humidity 50%

Length

L[mm]

Depth

T[mm]

Controlvoltage

EC motor[V]

Soundpres-

surelevel

LP

[dB/A]

Acoustic

powerlevel

LW

[dB/A]

Heat outputStandard

water

flow rate

qms

[kg/h]

Expo-nent

n [ ]

Mass

M[kg]

ΦL ∆T 50K

75/65/20°C[watts]

Φ ∆T 42K

70/55/20°C[watts]

Φ ∆T 30K

55/45/20°C[watts]

Φ ∆T 25K

50/40/20°C[watts]

2000

330

0

3

5

7

10

27

38

45

51

35

46

53

59

316

2527

4260

4775

5454

250

2133

3595

4030

4603

155

1507

2541

2848

3253

120

1251

2108

2363

2699

27,2

217,9

367,2

411,7

470,2

1,38

1,00

1,00

1,00

1,00

30,84

360

0

3

5

7

10

27

38

45

51

35

46

53

59

382

2880

5084

5853

6588

301

2430

4291

4939

5560

185

1718

3032

3491

3929

143

1425

2516

2897

3260

32,9

248,3

425,5

489,9

551,4

1,40

1,00

1,00

1,00

1,00

32,42

For individual calculations of heat outputs, see "General Information"

Page 7: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

56 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

KC4

81

Technical data

Technical dataHeight 155 mm (length 2750 mm)

Length

L[mm]

Depth

T[mm]

Controlvoltage

EC motor[V]

Soundpres-

surelevel

LP

[dB/A]

Acousticpower

levelLW

[dB/A]

Cooling capacity

Standardwaterflow

rateqms

[kg/h]

Expo-

nentn

[ ]

MassM

[kg]

PK ∆T 8 K18/20/27°C

[watts]

PS ∆T 8 K

18/20/27°C[watts]

PKN ∆T 10 K16/18/27°C

[watts]

PSN ∆T 10 K

16/18/27°C[watts]

PK ∆T 12 K12/16/26°C

[watts]

PS ∆T 12 K

12/16/26°C[watts]

PK ∆T 15 K8/14/26°C

[watts]

PS ∆T 15 K

8/14/26°C[watts]

2750

330

3

5

7

10

28

39

46

52

36

47

54

60

696

696

1035

1035

1156

1156

1383

1383

819

819

1326

1326

1416

1416

1755

1755

930

930

1610

1610

1659

1659

2116

2116

1089

744

2048

1648

2021

1794

2668

2668

350,0

566,7

605,1

750,0

0,72

1,10

0,90

1,06

45,05

360

3

5

7

10

28

39

46

52

36

47

54

60

719

719

1233

1233

1488

1488

1713

1713

867

867

1611

1611

1863

1863

2112

2112

1004

1004

1987

1987

2222

2222

2488

2488

1204

822

2578

2074

2766

2455

3050

3050

370,5

688,5

796,2

902,6

0,83

1,19

1,00

0,93

47,24

Total standard cooling capacity PKN and sensible standard cooling capacity PSN AT ∆T 10 K

Relative humidity 50%

LengthL

[mm]

DepthT

[mm]

Controlvoltage

EC motor

[V]

Sound

pres-

surelevel

LP

[dB/A]

Acoustic

powerlevelLW

[dB/A]

Heat outputStandard

water

flow rateqms

[kg/h]

Expo-nent

n

[ ]

MassM

[kg]

ΦL ∆T 50K

75/65/20°C[watts]

Φ ∆T 42K

70/55/20°C[watts]

Φ ∆T 30K

55/45/20°C[watts]

Φ ∆T 25K

50/40/20°C[watts]

2750

330

0

3

5

7

10

28

39

46

52

36

47

54

60

474

3791

6390

7163

8181

375

3199

5393

6045

6904

232

2261

3811

4272

4879

180

1876

3163

3545

4049

40,9

326,8

550,9

617,5

705,3

1,38

1,00

1,00

1,00

1,00

45,05

360

0

3

5

7

10

28

39

46

52

36

47

54

60

573

4320

7626

8779

9882

452

3646

6436

7409

8340

278

2576

4548

5236

5894

214

2138

3774

4345

4891

49,4

372,4

638,3

734,8

827,1

1,40

1,00

1,00

1,00

1,00

47,24

For individual calculations of heat outputs, see "General Information"

Page 8: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 57

Asc

othe

rm e

co

KC4

81

Dimensional drawings and connection images

ribb.

4-pipe connections without integrated valve

Con-

nection

system

Orde-

ring code

|VT|

ArrangementOrdering code

|ANB|

Con-nection

size

Ordering code Additio-nal price

per radiator

[EUR]

Heating Cooling

|VG| |RG| |VGK| |RGK|

2-pipe,

room side,

side by side

4

DD

BB

BB

DD

Euro

taper

with

union

nut

inter-

nal

thread 3/4“

64 64 64 64 –

2-pipe, to

the face,

side by side

4

33

11

11

33

Dimensional drawings KC481

Connections BB/DD

Side view from left Front view Side view from right

H1

T-33

T

HH

5H

4H2

H3

100137 137

L

Ø33

Ø19

63 40

H6

20

Ø15

14

10

Top view

L

Dimensional drawings for connection BB, connection DD mirrored

L

[mm]

Lribb.

[mm]

T

[mm]

H

[mm]

H1

[mm]

H2

[mm]

H3

[mm]

H4

[mm]

H5

[mm]

H6

[mm]

up to

2750L - 473

330130 3 - 50 59 100 64 100 43

155 3 - 85 60 106 65 101 68

360130 3 - 50 61 100 63 98 43

155 3 - 85 61 105 64 98 68

Detail

Condensate con-nection

Condensate connection

Condensate connection

Page 9: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

58 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

KC4

81

Dimensional drawings and connection images

Dimensional drawings KC481

Connection 11/33

Side view from left Front view Side view from right

H1

H2

H3

T-33

T2T3

T

T1

Ø33

H6

47

Ø19

H

100

L

Ø15

14

10

H4

H5 T4

T5

Top view

L

Dimensional drawings for connection 11, connection 33 mirrored

L

[mm]

Lribb.

[mm]

T

[mm]

T1

[mm]

T2

[mm]

T3

[mm]

T4

[mm]

T5

[mm]

H

[mm]

H1

[mm]

H2

[mm]

H3

[mm]

H4

[mm]

H5

[mm]

H6

[mm]

up to

2750L - 473

330 163 183 243 196 245

130 3 - 50 59 100 64 100 43

155 3 - 85 60 106 65 101 68

360 165 190 297 203 277

130 3 - 50 61 100 63 98 43

155 3 - 85 61 105 64 98 68

Number and version of cross-flow fans depending on the length

Cross-flow fan technical data,

incl. thermoelectric actuator

24 V DC

L = 1250 L = 2000 L = 2750

Length 1250 2000 2750

Number of EC motors 1 2 3

Number of fan wheels 2 4 6

max. power consumption [W] 20 38 56

max. current draw [mA] 87 165 243

max. inrush current for max. 2 min [mA] 428 507 585

max. volume flow rate [m³/h] 414 828 1242

For general information about "Control system", see corresponding chapter.

Detailed data (e.g. circuit diagrams) can be found in the installation instructions included with the trench convector and also requested,

if necessary.

Detail

Condensate con-nection

Condensate con-nection

ribb.

Page 10: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 59

Asc

othe

rm e

co

KC4

81

Pressure loss diagrams

Pressure loss diagrams

Pre

ssu

re lo

ss ∆

p [

mb

ar]

L 1250

L 2000L 1250

1

10

100

10 100 1000

L 27

50L

2000

L 27

50

Pre

ssu

re lo

ss ∆

p [

mb

ar]

1

10

100

10 100 1000

L 1250L 2000L 2000

L 27

50

L 27

50

L 1250

Water flow qm [kg/h] Water flow qm [kg/h]

Pre

ssu

re lo

ss ∆

p [

mb

ar]

1

10

100

10 100 1000

L 1250

L 2000L 2750

L 27

50L

2000

L 12

50

Pre

ssu

re lo

ss ∆

p [

mb

ar]

1

10

100

10 100 1000

L 1250

L 2000L 1250

L 2750L 2000

L 2750

Water flow qm [kg/h] Water flow qm [kg/h]

KC481 with H=130 and D=330

KC481 with H=130 and D=360

KC481 with H=155 and D=330

KC481 with H=155 and D=360

Page 11: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Heating and cooling in 4-conductor system

60 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

KC4

81

Prices and outputs

Height 130 mm (depth 330–360 mm)

Version KC 481 KC 481

Depth T [mm] 330 360

Price per piece [EUR/pc.] 403,20 435,25

Price per metre [EUR/m]without roll-up grille

604,02

with

roll-up

grille

736,27

without roll-up grille

602,87

with

roll-up

grille

749,29

LengthL

[mm]

Ribbed

convector lengthLribb.[mm]

Controlvoltage

EC motor[V]

Sound

pres-surelevel

LP

[dB/A]

Acousticpowerlevel

LW

[dB/A]

PK / PS

∆T 8 K[watts]

PKN / PSN

∆T 10 K[watts]

ΦS ∆T

50 K[watts]

Price[EUR]

Price[EUR]

PK / PS

∆T 8 K[watts]

PKN / PSN

∆T 10 K[watts]

ΦS ∆T

50 K[watts]

Price[EUR]

Price[EUR]

1250 777

03

5710

24

34 42 48

32

42 50 56

217

306383439

258

383469546

1541135

200122422578

1158,23 1323,54

239

409497552

286

515611684

1691403

249328553261

1188,84 1371,86

2000 1527

0

3

57

10

25

36 44

50

33

44 52

58

435

612766

878

516

766938

1092

308

2269

40024484

5156

1611,24 1875,74

479

819993

1105

572

10301222

1368

339

2806

49865710

6522

1640,99 1933,83

2750 2277

0

3

5

710

26

38

45 51

34

46

53 59

652

917

11491317

774

1149

14071638

462

3404

6003

67267734

2064,26 2427,94

718

1228

14901657

858

1545

18332052

508

4209

7479

85659783

2093,14 2495,80

Height 155 mm (depth 330–360 mm)

Version KC 481 KC 481

Depth T [mm] 330 360

Price per piece [EUR/pc.] 431,42 465,72

Price per metre [EUR/m]without roll-up grille

655,56

with

roll-up

grille

787,81

without roll-up grille

655,32

with

roll-up

grille

801,74

LengthL

[mm]

Ribbedconvector

lengthLribb.[mm]

Control

voltageEC motor

[V]

Sound

pres-sure

levelLP

[dB/A]

Acousticpower

levelLW

[dB/A]

PK / PS

∆T 8 K[watts]

PKN / PSN

∆T 10 K[watts]

ΦS ∆T 50 K

[watts]Price[EUR]

Price[EUR]

PK / PS

∆T 8 K[watts]

PKN / PSN

∆T 10 K[watts]

ΦS ∆T 50 K

[watts]Price[EUR]

Price[EUR]

1250 777

03

57

10

25

36 43

49

33

44 51

57

232

345385

461

273

442472

585

1581264

21302388

2727

1250,87 1416,18

240

411496

571

289

537621

704

1911440

25422926

3294

1284,87 1467,90

2000 1527

035

710

27 38

45 51

35 46

53 59

464690

771922

546884

9441170

31625274260

47755454

1742,54 2007,04480822

9921142

5781074

12421408

38228805084

58536588

1776,36 2069,20

2750 2277

0

357

10

28 39 46

52

36 47 54

60

69610351156

1383

81913261416

1755

474

379163907163

8181

2234,21 2597,9071912331488

1713

86716111863

2112

573

432076268779

9882

2267,85 2670,51

Ribbed convector length = Length floor pan - 473 mm. Standard heat output at 75 / 65 / 20 °C (∆T 50 K)

Standard cooling capacity at 16 / 18 / 27°C (∆T 10 K); at ∆T 10 K and ∆T 8 K, relative humidity 50 %: PK = PSRR: Aluminium roll-up grille, natural colour, anodised (standard). On KC481 with a linear grille, reduced output must be expected.

Page 12: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 61

Prod

uct

deta

ils

Control system

Control systemIn the course of converting from AC to EC technology for the

Ascotherm eco fan motors, a powerful and innovative control

system was developed. The new Ascotherm eco control system

conforms to the growing demands for both modern single-room

control and connection to a building management system via a

KNX BUS.

Attention was also payed to ensure easy installation during de-

velopment of the control system. The control board is compatible

with all Ascotherm eco trench convectors having EC cross-flow

fans (KRN81, KC281, KC481) and already installed at the factory

in a casing with protection class IP65. The installed electrical

components are already completely wired and thus ready for

connection upon arrival from the factory. Customer-specific

upgrades of the system in the form of various signal inputs and

outputs (plug-in contacts) are possible at any time.

Electrical connection

In a standard situation, only the mains supply (220-240 V AC, con-

ductor cross-section of at least 1,5 mm²) and the communication

line to the Ascotherm eco room thermostat (wire cross-section

0,25 mm², twisted-pair conductors, max. permissible line length

30 m) need to be connected on site.

Depending on the configuration and type of optional control

components, the following additional external connections can

be provided on-site:

• Internal bus line to additional convectors in a combined

control system (up to 6 convectors), wire cross-section at least

0,25 mm², max. permissible line length 100 m

• Bus line to a higher-level building management system, wire

cross-section at least 0,25 mm², max. Permissible line going

700 m between Ascotherm eco with KNX plug-in card and IP

router

• Line connection to an external room temperature sensor

• Line connection to an RF receiver (for receiving input signals

from window contact sensors and presence detectors)

The following optional control components are wired inside the

floor pan.

Connection can be made at the factory (with a corresponding

order) or by the installer:

• Thermoelectric actuator 24 V DC, control voltage 0-10 V DC

• Surface sensor for flow temperatures (possible for heating

and cooling circuits on the KC481)

• Dew point sensor (KC281 and KC481)

• KNX plug-in card

For more detailed information about electrical connections, see

the electrical installation instruction.

Commissioning

Every Ascotherm eco trench convector is supplied with all control

parameters preset at the factory. Depending on the situation

(e.g. control with or without a building management system),

convector type and individual needs of the customer, control sys-

tem parameters can be set during commissioning with the aid of

an Ascotherm eco room thermostat (see accessory ZE00770003).

Control characteristics / functional overview

• Infinitely variable control of the fan speed in relation to the

room's heat requirement (difference between set tempera-

ture and room temperature)

• Synchronised control of fan speed and valve stroke (water

flow) for a hydraulically balanced pipe system and especial-

ly energy-efficient operation (maintenance of a minimum

spread between flow and return temperature). According to a

preliminary study conducted by Prof. Dr.-Ing. Rainer Hirsch-

berg, University of Aachen, this can save 8% of the thermal

energy and more than 80% of the electrical energy (recircula-

tion) compared to systems without synchronised control.

Heating Cooling

Fan

sp

eed

n

Fan

sp

eed

n

Valve stroke Valve stroke

• Automatic fast heating outside the "comfort range" (+/- 0,5°C

of the set temperature) – may be deactivated by means of a

parameter

• Adjustable limit of the fan speed within the "comfort range"

• "Quiet heating" (without fan operation) in the lower output

range

• Frost protection function via room temperature sensor

• Connection to a building management system possible via an

optional KNX plug-in card (only one per combined control

system needed)

1 2 3

6 5 4

• Individual adjustments of the control parameters (e.g. time

limit on changes to the set temperature) are possible even

when controlling through a building management system

• Control of up to 6 convectors (combined control system) possi-

ble via one room thermostat

1 2 3

6 5 4

Control board

Building management system

KNX BUS

Router IP Ethernet / IP

KNX card

BUS

Room thermostat

Room thermostat

BUS

Control board

Page 13: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

62 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Prod

uct

deta

ils

Control system

• In a combined control system, control based on several room

temperatures (sensing via external room temperature sensors

– optional accessory) is possible

• even greater energy efficiency possible through optional ac-

cessory incorporation of window contact sensors and presence

detectors into the control system (both wireless)

• automatic changeover in the 2-pipe cooling mode through

installation of flow temperature sensors (accessory)

Programmable Ascotherm eco room thermostat

The control unit for the Ascotherm eco control system with a

large multifunction display and functional input elements for

maximum operating comfort.

AUTO

PROG

1,50 m

1,10 m

Mind 20 cm

Product characteristics

• Operation via a rotary navigator and function keys

• Multifunctional liquid crystal display (LCD) with automatic

backlighting (blue)

• Individually programmable timer-controlled programs

• integrated room temperature sensor

• Supply voltage via BUS connection to control board

• Real-time clock

• individually adjustable base display

• BOOSTER function

• Holiday function

• Pictograms for depiction, internationally usable

• Suitable for wall mounting (with or without in-wall pattress

box)

• Plastic casing, colour similar to RAL 9010

• Technical data:

- Voltage supply via BUS connection to control board, vol-

tage 12 - 28 V

- Protection class II

- Dimensions L x H x T = 81 x 135 x 33 mm

- Protection type IP 30

- Memory duration of time switch in the event of mains

failure: 2 hours.

- Operating temperature 0°C to + 40°C (10% - 90% relative

humidity)

Suitable for wall mounting (with or without in-wall pat-

tress box)

Plastic casing, colour similar to RAL 9010

AUTO

PROG

Pictogram meanings

Heating Manual control

Cooling Absent

Comfort mode Fast heating or cooling

Economy mode Error in range (see mode i)

Frost protection mode Opening detection

Off Cancel

FanConnected building ma-

nagement system

Functions

Operation: Entry of control parameters (e.g. set

temperatures) – operation via selection

menu and function keys

Display: Display of system-relevant parameters

and operating conditions

Temperature

measurement:

Room temperature via integrated tem-

perature sensor

Timed programs: Individual timed programs - several

switching points between economy and

comfort mode possible per day

Fault management: Fault display in the INFO mode

Shortcut keys: Fast access to manual control functions

in the AUTO mode via the function keys

Manual fan control: In 4 steps (0 -1 -2 -3) with fixed fan

speeds for an adjustable period of time

Manual operating

mode selection:

Changeover from economy ó comfort

for an adjustable period of time

BOOSTER (manual): Fast heating for a certain period of time

(15-30-60 min)

Holiday function: Frost protection activated for a free

selectable number of days (1-365)

Group control: Control of up to 6 ASCOTHERM eco

trench convectors possible with one

room thermostat

Individual adjust-

ment:

of the control parameters set by a buil-

ding management system (e.g. set-

temperature values, operating mode)

for a limited period of time

DisplayIlluminatedbackground

Information mode

Time setting

Programming

Opening markingof the cover

Function keys

Automatic operation

Comfort setting

Economy setting

Off

Page 14: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 63

Prod

uct

deta

ils

Fixing and floor pan adjustment

Fixing and floor pan adjustment

Fixing type Description and dimensional drawings

With

adjustable

feet

T

H

L

H1

2 -

25

Number of feet per side

Depending on the length

Length L [mm]

Number of fixing lugs

[pc.]

1000 3

1250 3

1500 3

1750 4

2000 4

2250 4

2500 5

2750 5

3000 5

3250 7

3500 8

3750 8

4000 8

4250 8

4500 8

4750 9

5000 10

Adjusting screw

Fixing lug

(from outside only)

Screw/anchor

(for fixing lug only)

Version Height H [mm]

H1 [mm]

KRP91 92 3 - 30

120 3 - 50

150 3 - 85

200 3 - 105

KRN92 110 3 - 50

150 3 - 85

200 3 - 105

KRN81 110 3 - 50

KC 281 130 3 - 50

155 3 - 85

KC 481 130 3 - 50

155 3 - 85

On-site threaded bar for floor

distance of max. 100 mm

Page 15: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

64 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Prod

uct

deta

ils

Fixing and floor pan adjustment

Notes

Page 16: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 65

Prod

uct

deta

ils

The new connection sets with factory preset kV valves

Control curves for valve inserts

Standard valve insert V5K S

Presetting 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,56 8

kvs value up to 0,16 0,21 0,24 0,30 0,34 0,41 0,44 0,54 0,65 0,82 0,98 1,11 1,23 1,33 1,43

Pre

ssu

re lo

ss in

mb

ar

321 4 5 6

87

1,5 2,5 3,5 4,5 5,5

7,56,5

100

1000

10 1002 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9

1000

10

2

345

6 78 9

2

345

6 78 9

Water flow in kg/h

Connection sets for the Ascotherm ecoIt is recommended that the Ascotherm eco be fitted with preset

kv connection sets (see accessories range). On request, the instal-

lation can be done at the factory.

The Ascotherm eco units are fitted with preset connection sets

depending on the heating or cooling capacity.

Ascotherm eco units can also be fitted with the fine-adjusting

valve. The adjustable valve insert permits reproducible settings of

low water flow rates. The setting values can be taken from the

diagram.

Page 17: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

66 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Prod

uct

deta

ils

The new connection sets with factory preset kV valves

Valve performance limits of valve inserts for the Ascotherm eco connection setsPlease note the valve performance limits in relation to the system parameters

Standard valve insert V5K S

Presetting kvs value Δp [mbar]

Temperature difference ΔT [K]

2 4 6 8 10 12 15 20

1 0,16

60 92 183 275 366 458 549 686 91580 106 211 317 423 528 634 793 1057

100 118 236 354 473 591 709 886 1182120 129 259 388 518 647 777 971 1294140 140 280 419 559 699 839 1049 1398

1,5 0,21

60 120 240 360 480 601 721 901 120180 139 277 416 555 694 832 1040 1387

100 155 310 465 620 775 930 1163 1551120 170 340 510 680 849 1019 1274 1699140 183 367 550 734 917 1101 1376 1835

2 0,24

60 137 275 412 549 686 824 1030 137380 159 317 476 634 793 951 1189 1585

100 177 354 532 709 886 1063 1329 1772120 194 388 582 777 971 1165 1456 1941140 210 419 629 839 1049 1258 1573 2097

2,5 0,30

60 169 337 506 675 844 1012 1266 168780 195 390 585 779 974 1169 1461 1948

100 218 436 654 871 1089 1307 1634 2178120 239 477 716 955 1193 1432 1790 2386140 258 516 773 1031 1289 1547 1933 2578

3 0,34

60 194 389 583 778 972 1167 1459 194580 225 449 674 898 1123 1347 1684 2246

100 251 502 753 1004 1255 1506 1883 2511120 275 550 825 1100 1375 1650 2063 2750140 297 594 891 1188 1485 1782 2228 2971

3,5 0,41

60 235 469 704 938 1173 1407 1759 234580 271 542 812 1083 1354 1625 2031 2708

100 303 606 908 1211 1514 1817 2271 3028120 332 663 995 1327 1658 1990 2487 3317140 358 716 1075 1433 1791 2149 2687 3582

4 0,44

60 252 503 755 1007 1258 1510 1888 251780 291 581 872 1162 1453 1744 2180 2906

100 325 650 975 1300 1625 1950 2437 3249120 356 712 1068 1424 1780 2136 2669 3559140 384 769 1153 1538 1922 2307 2883 3845

4,5 0,54

60 309 618 927 1236 1544 1853 2317 308980 357 713 1070 1427 1783 2140 2675 3567

100 399 798 1196 1595 1994 2393 2991 3988120 437 874 1310 1747 2184 2621 3276 4368140 472 944 1415 1887 2359 2831 3539 4718

5 0,65

60 372 744 1115 1487 1859 2231 2789 371880 429 859 1288 1717 2147 2576 3220 4293

100 480 960 1440 1920 2400 2880 3600 4800120 526 1052 1577 2103 2629 3155 3944 5258140 568 1136 1704 2272 2840 3408 4260 5679

5,5 0,82

60 469 938 1407 1876 2345 2814 3518 469080 542 1083 1625 2166 2708 3250 4062 5416

100 606 1211 1817 2422 3028 3633 4541 6055120 663 1327 1990 2653 3317 3980 4975 6633140 716 1433 2149 2866 3582 4299 5374 7165

6 0,98

60 561 1121 1682 2242 2803 3363 4204 560680 647 1295 1942 2589 3236 3884 4855 6473

100 724 1447 2171 2895 3618 4342 5428 7237120 793 1586 2378 3171 3964 4757 5946 7928140 856 1713 2569 3425 4281 5138 6422 8563

6,5 1,11

60 635 1270 1905 2540 3175 3810 4762 634980 733 1466 2199 2933 3666 4399 5499 7331

100 820 1639 2459 3279 4098 4918 6148 8197120 898 1796 2694 3592 4490 5388 6734 8979140 970 1940 2910 3879 4849 5819 7274 9699

7 1,23

60 704 1407 2111 2814 3518 4221 5277 703680 812 1625 2437 3250 4062 4874 6093 8124

100 908 1817 2725 3633 4541 5450 6812 9083120 995 1990 2985 3980 4975 5970 7462 9950140 1075 2149 3224 4299 5374 6448 8060 10747

7,5 1,33

60 761 1522 2282 3043 3804 4565 5706 760880 878 1757 2635 3514 4392 5271 6588 8785

100 982 1964 2946 3929 4911 5893 7366 9821120 1076 2152 3228 4304 5379 6455 8069 10759140 1162 2324 3486 4648 5810 6973 8716 11621

8 1,43

60 818 1636 2454 3272 4090 4908 6135 818080 945 1889 2834 3778 4723 5667 7084 9445

100 1056 2112 3168 4224 5280 6336 7920 10560120 1157 2314 3470 4627 5784 6941 8676 11568140 1249 2499 3748 4998 6247 7497 9371 12495

Page 18: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 67

Prod

uct

deta

ils

The new connection sets with factory preset kV valves

Fine-adjusting valve insert V5K F

Presetting 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,56 8

kvs value up to 0,06 0,06 0,07 0,07 0,08 0,09 0,1 0,11 0,12 0,15 0,17 0,21 0,25 0,37 0,5

Pre

ssu

re lo

ss in

mb

ar

22,5

11,5

3 4 5 6 7 83,5 4,5 5,5 6,5 7,5

100

1000

10 1002 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9

1000

10

2

345

6 78 9

2

345

6 78 9

Water flow in kg/h

Page 19: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

68 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Prod

uct

deta

ils

The new connection sets with factory preset kV valves

Valve performance limits of valve inserts for the Ascotherm eco connection setsPlease note the valve performance limits in relation to the system parameters

Fine-adjusting valve insert V5K F

Presetting kvs value Δp [mbar]

Temperature difference ΔT [K]

2 4 6 8 10 12 15 20

1 0,06

60 34 69 103 137 172 206 257 34380 40 79 119 159 198 238 297 396

100 44 89 133 177 222 266 332 443120 49 97 146 194 243 291 364 485140 52 105 157 210 262 315 393 524

1,5 0,06

60 34 69 103 137 172 206 257 34380 40 79 119 159 198 238 297 396

100 44 89 133 177 222 266 332 443120 49 97 146 194 243 291 364 485140 52 105 157 210 262 315 393 524

2 0,07

60 40 80 120 160 200 240 300 40080 46 92 139 185 231 277 347 462

100 52 103 155 207 258 310 388 517120 57 113 170 227 283 340 425 566140 61 122 183 245 306 367 459 612

2,5 0,07

60 40 80 120 160 200 240 300 40080 46 92 139 185 231 277 347 462

100 52 103 155 207 258 310 388 517120 57 113 170 227 283 340 425 566140 61 122 183 245 306 367 459 612

3 0,08

60 46 92 137 183 229 275 343 45880 53 106 159 211 264 317 396 528

100 59 118 177 236 295 354 443 591120 65 129 194 259 324 388 485 647140 70 140 210 280 350 419 524 699

3,5 0,09

60 51 103 154 206 257 309 386 51580 59 119 178 238 297 357 446 594

100 66 133 199 266 332 399 498 665120 73 146 218 291 364 437 546 728140 79 157 236 315 393 472 590 786

4 0,10

60 57 114 172 229 286 343 429 57280 66 132 198 264 330 396 495 660

100 74 148 222 295 369 443 554 738120 81 162 243 324 404 485 607 809140 87 175 262 350 437 524 655 874

4,5 0,11

60 63 126 189 252 315 378 472 62980 73 145 218 291 363 436 545 727

100 81 162 244 325 406 487 609 812120 89 178 267 356 445 534 667 890140 96 192 288 384 481 577 721 961

5 0,12

60 69 137 206 275 343 412 515 68680 79 159 238 317 396 476 594 793

100 89 177 266 354 443 532 665 886120 97 194 291 388 485 582 728 971140 105 210 315 419 524 629 786 1049

5,5 0,15

60 86 172 257 343 429 515 644 85880 99 198 297 396 495 594 743 991

100 111 222 332 443 554 665 831 1108120 121 243 364 485 607 728 910 1213140 131 262 393 524 655 786 983 1311

6 0,17

60 97 194 292 389 486 583 729 97280 112 225 337 449 561 674 842 1123

100 126 251 377 502 628 753 942 1255120 138 275 413 550 688 825 1031 1375140 149 297 446 594 743 891 1114 1485

6,5 0,21

60 120 240 360 480 601 721 901 120180 139 277 416 555 694 832 1040 1387

100 155 310 465 620 775 930 1163 1551120 170 340 510 680 849 1019 1274 1699140 183 367 550 734 917 1101 1376 1835

7 0,25

60 143 286 429 572 715 858 1073 143080 165 330 495 660 826 991 1238 1651

100 185 369 554 738 923 1108 1385 1846120 202 404 607 809 1011 1213 1517 2022140 218 437 655 874 1092 1311 1638 2184

7,5 0,37

60 212 423 635 847 1058 1270 1587 211680 244 489 733 978 1222 1466 1833 2444

100 273 546 820 1093 1366 1639 2049 2732120 299 599 898 1197 1497 1796 2245 2993140 323 647 970 1293 1616 1940 2425 3233

8 0,50

60 286 572 858 1144 1430 1716 2145 286080 330 660 991 1321 1651 1981 2477 3302

100 369 738 1108 1477 1846 2215 2769 3692120 404 809 1213 1618 2022 2427 3034 4045140 437 874 1311 1748 2184 2621 3277 4369

Page 20: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 69

Prod

uct

deta

ils

The new connection sets with factory preset kV valves

Factory kV presetting of the valves

KRP91

H [mm] 92 120 150 200

T [mm] 185 210 260 310 360 400 185 210 260 310 360 400 185 210 260 310 360 400 185 210 260 310 360 400

L [mm] Preset kV values

1000 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5*

1250 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 2,5

1500 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5

1750 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5

2000 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 4,5

2250 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 4,5 4,5

2500 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 4,5

2750 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5

3000 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5

3250 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5

3500 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 6,0

3750 5,5* 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 6,0

4000 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0

4250 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0

4500 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 6,0 2,5 4,5 4,5 4,5 6,0 6,0

4750 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 6,0 4,5 4,5 4,5 4,5 6,0 6,0

5000 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0 4,5 4,5 4,5 6,0 6,0 6,0

* Fine-adjusting valve

Dimensioning:

Heat outputs at 70 / 55 / 20°C,

Pressure loss across the valve 100 mbar

Page 21: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

70 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Prod

uct

deta

ils

The new connection sets with factory preset kV valves

Factory kV presetting of the valves

KRN92

H [mm] 110 150 200

T [mm] 185 210 260 310 360 400 185 210 260 310 360 400 185 210 260 310 360 400

L [mm] Preset kV values

1000 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5*

1250 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5*

1500 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5*

1750 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 2,5

2000 5,5* 5,5* 5,5* 5,5 5,5 5,5 5,5* 5,5* 5,5* 5,5* 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5

2250 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5

2500 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5

2750 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5

3000 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5

3250 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 4,5 4,5

3500 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 4,5 5,5* 5,5* 2,5 2,5 4,5 4,5

3750 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5

4000 5,5* 5,5* 2,5 2,5 2,5 4,5 5,5* 5,5* 2,5 2,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5

4250 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5

4500 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 2,5 2,5 4,5 4,5 4,5

4750 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5

5000 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5

* Fine-adjusting valve

Dimensioning:

Heat outputs at 70 / 55 / 20°C,

Pressure loss across the valve 100 mbar

Page 22: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 71

Prod

uct

deta

ils

The new connection sets with factory preset kV valves

Factory kV presetting of the valves

KRN81

H [mm] 110

T [mm] 185 210 260 310 360

L [mm] Preset kV values

1250 2,5 2,5 2,5 2,5 4,5

1500 2,5 2,5 2,5 2,5 4,5

1750 2,5 2,5 4,5 4,5 4,5

2000 4,5 4,5 4,5 4,5 6

2250 4,5 4,5 4,5 4,5 6

2500 4,5 4,5 6 6 6

2750 4,5 6 6 6 6

3000 4,5 6 6 6 6

3250 4,5 6 6 6 6

3500 6 6 6 6 8

3750 6 6 6 6 8

4000 6 6 6 8 8

Dimensioning:

Heat outputs at 70 / 55 / 20°C,

Pressure loss across the valve 100 mbar

Page 23: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoProduct details

72 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Prod

uct

deta

ils

The new connection sets with factory preset kV valves

Factory kV presetting of the valves

KC 281

H [mm] 130 155

T [mm] 310 360 310 360

L [mm] Preset kV values

1250 6 6 6 8

2000 0* 0* 0* 0*

2750 0* 0* 0* 0*

Note:

On the KC2 81, the valve inserts are preset in relation to the cooling capacity, since the water flow rate required for cooling is usually

higher than for heating.

Dimensioning:

Cooling capacities at 16 / 18 / 27°C,

Pressure loss across the valve 100 mbar

KC 481

H [mm] 130 155

T [mm] 330 360 330 360

L [mm] Preset kV values

1250 6 6 6 6

2000 0* 0* 0* 0*

2750 0* 0* 0* 0*

Dimensioning:

Cooling capacities at 16 / 18 / 27°C,

Pressure loss across the valve 100 mbar

KC 481

H [mm] 130 155

T [mm] 330 360 330 360

L [mm] Preset kV values

1250 4,5 4,5 4,5 4,5

2000 6 8 6 8

2750 8 0* 8 0*

Dimensioning:

Heat outputs at 70 / 55 / 20°C,

Pressure loss across the valve 100 mbar

* Wherever kv preset values are stated as 0, the maximum convector outputs are above the

valve performance limits for the indicated system parameters. In this case, it is necessary to check whether the dimensioned output is

within the valve performance limits. See data under valve performance limits.

Page 24: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoArbonia Individual

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 73

Asc

othe

rm e

co

Indi

vidu

al

Special versions

Angled version

• Available for all versions and for empty pan

• Angle can be between 50° and 320°

Please provide a dimensional drawing or template with the

order.

• Feasibility depends on engineering review

• Radiator must still be transportable

Dimensional drawing

Orde-

ring code |BES|

Additional price / bevel cut

[EUR]

Floor pan

Linear grille

Roll-up grille

Single

bevel

90°

L2

L1

TWA

W A T

L1

L2

270°

76

771)49,00 46,00 164,00

WA

T

L1

L2

αL1

L2

α

WA

T

1) Characteristic 77 for bevel cut at both ends

L1, L2: Length of the limbs, measured on the wall

α: AngleT: Depth floor panWA: Wall spacing

Page 25: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoArbonia Individual

74 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

Indi

vidu

al

Special versions

Curved version

• Available for KRP91 (other versions on request)

• Bending radius R: at least 1000 mm

Please provide a dimensional drawing or template with the

order.

• Feasibility depends on engineering review

• Radiator must still be transportable

Dimensional drawing

Orde-

ring code

|BES|

Additional

price per radiator

[EUR]

L

R T

W A

Inside radius

70 On requestW A

T

R

L

Outside radius

L: Streched lengthR: Bending radius (wall radius)T: Depth floor pan

WA: Wall spacing

Page 26: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoArbonia Individual

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 75

Asc

othe

rm e

co

Indi

vidu

al

Special versions

Column section version

• Available for all versions and for empty pan

Please provide a dimensional drawing or template with the

order.

• Feasibility depends on engineering review

• Radiator must still be transportable

Dimensional drawing

Orde-ring

code

IBESI

Additional price per column section

[EUR]

Floor

pan

Linear

grille

Roll-up

grille

Column section according to drawing

75On

request

On

request

On

request

column section in floor pan column section in linear grille column section in roll-up grille

A

Ød C

A

Ød C

A

Ød C

A B

C

A B

C

A B

C

d: Diameter

A: Inset dimension for length

B: Edge dimension

C: Inset dimension for depth

Page 27: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoArbonia Individual

76 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

Indi

vidu

al

Special versions

Version with impact sound insulation

Description

Orde-ring code

IEBTI

Additional price per

metre

[EUR]

Without impact

sound insulation

• Standard version wit-

hout

With impact sound

insulation

TS1 39,00

Coupled Ascotherm• radiators are supplied individually

• Connection material (flexible connection hoses etc. available as accessory)

• Only for versions KRP91 (not for H 150 and H 200), KRN92, KRN81

• On version KRN81 (max. up to 4 motors)

Con-

nection

system Description

Sequence of coupled radiatorsΔ(enter in column "Special characteri-stics")

Ordering

code

|KHP|

Additio-

nal price per radi-

ator

[EUR]

Connec-

tion on

the same

side from

the left

• Radiator position 2 re-

peats when coupling

more than 3 radiators

• Please provide a draw-

ing with the order

Initial radiator

1

Middle radiator

2

Final radiator

3

75 67,00Connec-

tion on

the same

side from

the right

• Radiator position 2 re-

peats when coupling

more than 3 radiators

• Please provide a draw-

ing with the order

Final radiator

3

Middle radiator

2

Initial radiator

1

Impact sound insulation 4 mm

Page 28: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoArbonia Individual

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 77

Asc

othe

rm e

co

Indi

vidu

al

Special versions

Air connection with air connection valve

Number

of air

connec-

tions

|LAZ| Length [mm] Description and dimensional drawings

Air connection

arrangement

|LAP|1)

Height H

[mm]

Connec-

tion size

|LAG|

Additional

price per

additional

connec-

tion [EUR]

1 ≤ 3000 mm • Standard: 1 air connection, incl. air valve

• Additional air connections possible (max. number and location on request)

• Air connections are distributed evenly (to the

extent technically possible)

• The exact positioning of the air connections can be seen in the drawing

– 110, 150, 200 63 39,00

150, 200 80 41,00

200 100 44,00

200 125 46,00

2 > 3000 mm • Standard: 2 air connections, incl. air valves

• Additional air connections possible (max.

number and location on request)

• Air connections are distributed evenly (to the

extent technically possible)

• The exact positioning of the air connections

can be seen in the drawing

• No clear

assignment

of positions,

since floor pan

joined at the

factory

110, 150, 200 63 39,00

150, 200 80 41,00

200 100 44,00

200 125 46,00

Special connections - Version per drawing - Ordering code LAP = SON On re-

quest

1) The positioning of the air connections is affected slightly by the arrangement of the cross bracing in the floor pan, example: connec-

tion F (room side, centred) = "approx. centred"

The exact dimensions/positions can be seen in the drawing and need to be approved by the customer.

Number and positions of the air connections

L/2 ±75L/2 ±75L ≤ 3000

L/4 ±150 L/4 ±150L > 3000

Page 29: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoArbonia Individual

78 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Asc

othe

rm e

co

Indi

vidu

al

Special versions

Additional special versions

Description

Cha-racteri-

stic

Orde-ring

code

Additional price per radiator

[EUR]

Pressure version High-pressure version16 bar (1600 kPa) |DRU| 16 + 5 %

Special versions Special length for heating 1)

• > 1000 mm (KRP91 and KRN92)

• > 1250 mm possible (KRN81)

|BES| SBL Next-larger standard

length

Special length for heating and cooling 1)

• > 1250 mm possible |BES| SBL On request

Extra-short length (smaller than smallest standard length)

• 600 mm - < 1000 mm possible (KRP91 and KRN92)

• 1000 mm - < 1250 possible (KRN81)

• 850 mm - < 1250 mm possible (KC281)

• 1050 mm - < 1250 mm possible (KC481)

|BES| SBL On request

Special depth acc. to drawing 2) |BES| SBT On request

Special height according to drawing 3) |BES| SBH On request

Fixing Fixing with special bracket (in case of high soil structure) On request

Special finish Finished in special colour (no RAL colour)

Aluminium linear grille / aluminium roll-up grille |AUS| SF On request

Floor pan and register |FAR1| 99 On request

Finished in other RAL colour (standard is RAL 7016)

Floor pan and register |FAR1| SF + 30 %

1) Provide exact length2) Provide exact depth3) Provide exact height

Page 30: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoAscotherm® eco Individual

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 79

Asc

othe

rm e

co

Indi

vidu

al

On request, accessory components, available factory-installed

Available on request

Description

Cha-racteri-

stic

Orde-ring

code

Additional price per

metre

[EUR]

Edge bar

Anodised in

natural colour ELO = Anodised in natural colour |RDL| ELO –

Colour anodised BRO = Anodised in bronze finish

MES = Anodised in brass finish DKS = Anodised in dark silver finish

SWZ = Anodised in black finish EDS = Anodised in stainless steel finish

|RDL| BRO

MESDKS

SWZEDS

11,00

11,0011,00

11,0011,00

Paint finish FAR1 = Edge bar finished as floor pan/register |RDL| FAR1 –

FAR2 = Edge bar finished as top grille |RDL| FAR2 49,00

Air-intake filter • For KRN81 air-intake filter PPI 30 dark 90 x 3 mm |FVL| FV 8,00

• For KC281 and KC481 air -ntake filter PPI 30 dark 140 x 3 mm |FVL| FV 9,00

Accessory components, factory-installed

Description

Cha-

racteri-stic

Orde-

ring code

Additional price per

radiator [EUR]

Installation Connection

set, straight

form with pre-

set kv valve

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread

with euro taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread

with euro taper

– nickel-plated• Threaded fitting attached only hand-tight

• For all KRN,

KRP91 and

KC281 with

connection

11 or 33

|VRS| VRS 44,00

• For KC481

with connec-

tion 11 or 33

|VRS| VRS 88,00

Connection

set, angled

version with

preset kv valve

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread

with euro taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread

with euro taper

– nickel-plated• Threaded fitting attached only hand-tight

• For KC281

with connec-

tion BB or

DD

|VRS| VRS 44,00

• For KC481

with connec-

tion BB or

DD

|VRS| VRS 88,00

Connection

set, angled

version with

preset kv val-

ve, connection

arrangement

66/88

Consisting of:

• Valve base with factory preset kv valve

– DN 15, outlet 3/4“ external thread with

euro taper, inlet 1/2“ internal thread

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread

with euro taper

– nickel-plated• Threaded fitting attached only hand-tight

• For KRP91,

KRN92 and

KRN81

|VRS| VRS 44,00

Thermoelec-

tric actuator

230 V AC

• Factory-installed • Only in conjunction with VRS

• For KRP91

and KRN92

|STT| STT 29,00

Thermoelec-

tric actuator

24 V DC

• Factory-installed and with controller board wired

• Only in conjunction with VRS

• For KRN81

and KC281

|STT| STT 92,00

• For KC481 |STT| STT 184,00

KNX plug-

in card (for

KRN81, KC281

and KC481)

• for installation in the Ascotherm eco

control board to connect to KNX networks,

only 1 per convector group is needed (up to

6 convectors)

• For KRN81,

KC281 and

KC481

|GLT| KNX 146,00

Page 31: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoAccessories

80 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Acc

esso

ries

Empty floor pan

1) Dimensions |HOE| and |MT| need to be stated with the order (for description, see chapter "General information")

Prices for other colours, see chapter "Ascotherm top grilles" and "Special versions".

Ascotherm eco empty floor panFor the ... Arbonia offers an Ascotherm empty floor pan in its accessories range.

The range available (H / B / T) and the special or extra-short empty floor pan lengths are listed at the individual versions.

Description

Product code Characteristic

Dimensi-ons

Ordering code

ProductVersion

Ordering code

|3|

Price

perpiece

[EUR/pc.]

Priceper

metrewithout grille

[EUR/m]

Priceper

metrewith grille[EUR/m]

Priceper

metrewithout grille

[EUR/m]|3.1| |3.4|

Empty

floor pan

ZA0108

Dimensions

• Heights:

– 92, 110, 120, 130,

150, 155, 200 mm

• Depths:

– 185, 210, 260,

310, 330, 360, 400

mm

• Lengths variable:

– 200–3000 mm

Finish

• Standard in anthraci-

te grey

(RAL 7016 matt

finish)

Top grille version

• Standard in alumi-

nium, anodised in

natural colour

Material

• Galvanised sheet

steel, colour-coated

92 185 ZA0108 1)

111,30 89,04 179,96 179,96

210 111,30 100,17 195,82 195,82

260 111,30 111,30 219,93 219,93

310 111,30 122,43 254,68 254,68

360 111,30 133,56 279,98 279,98

400 111,30 144,69 302,03 302,03

110 185 ZA0108 1)

111,30 100,17 191,09 191,09

210 111,30 111,30 206,95 206,95

260 111,30 122,43 231,06 231,06

310 111,30 133,56 265,81 265,81

360 111,30 144,69 291,11 291,11

400 111,30 155,82 313,16 313,16

120 185 ZA0108 1) 111,30 100,17 271,38 271,38

210 111,30 111,30 282,62 282,62

260 111,30 122,43 296,68 296,68

310 111,30 133,56 191,09 191,09

360 111,30 144,69 206,95 206,95

400 111,30 155,82 231,06 231,06

130 310 ZA0108 1) 111,30 139,13 265,81 265,81

330 111,30 144,70 291,11 291,11

360 111,30 150,26 313,16 313,16

150 185 ZA0108 1)

111,30 111,30 202,22 202,22

210 111,30 122,43 218,08 218,08

260 111,30 133,56 242,19 242,19

310 111,30 144,69 276,94 276,94

360 111,30 155,82 302,24 302,24

400 111,30 166,95 324,29 324,29

155 310 ZA0108 1)

111,30 150,26 282,51 282,51

330 111,30 155,83 293,75 293,75

360 111,30 161,40 307,82 307,82

200 185 ZA0108 1)

111,30 122,43 213,35 213,35

210 111,30 133,56 229,21 229,21

260 111,30 144,69 253,32 253,32

310 111,30 155,82 288,07 288,07

360 111,30 166,95 313,37 313,37

400 111,30 178,08 335,42 335,42

Page 32: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco Accessories

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 81

Acc

esso

ries

1) Dimensions characteristic |MT| and ordering code need to be stated when ordering (for description, see chapter "General informati-on" and colour chart)

Top grilles

are attractively shaped, solid and robust. There are practically

no limits to how they can be integrated into the architectural

design of the room, thanks to the choice of various profile forms,

materials and

Surface finishes. The grilles can easily be removed for cleaning

and then returned to their original positions.

Ascotherm eco top grilles

Description

Product code Characteristic

Dimen-sions

Ordering

code|MT|

Version

ProductVersion

Price

per

metre

[EUR/m]]Description

Orde-

ring code

Alumini-

um linear

grille

ZA0109

Dimensions• Length up to 5000 mm

– up to 3000 mm in one

piece– as of 3001 mm in two

pieces

• Height 20 mm

• Bar width 6 mm

• Bar spacing 10 mm

• Open cross-section 60 %

Finish

• Anodised in natural or co-

lour, powder-coated in RAL

colours

• Anodised colours

– Natural (ELO)

– Bronze (BRO)

– Dark silver (DKS)

– Brass (MES)

– Black (SWZ)

• Cut surfaces in aluminium

colour if linear grille is in

two pieces

Version

• Longitudinal profile bars

are fixedly connected to

aluminium angle profiles by

means of a pressure process

every 200-300 mm

Material

• Aluminium profiles

T = 185 Natural anodised ELO ZA0109 1) 90,92

Colour anodised BROMESDKS

SWZ

ZA0109 1) 161,76

Finished in colour of

choice

LAC ZA0109 1) 118,20

T = 210 Natural anodised ELO ZA0109 1) 95,65

Colour anodised BROMESDKS

SWZ

ZA0109 1) 166,50

Finished in colour of

choice

LAC ZA0109 1) 124,33

T = 260 Natural anodised ELO ZA0109 1) 108,63

Colour anodised BROMES

DKS

SWZ

ZA0109 1) 179,49

Finished in colour of

choice

LAC ZA0109 1) 141,22

T = 310 Natural anodised ELO ZA0109 1) 132,25

Colour anodised BRO

MES

DKSSWZ

ZA0109 1) 203,10

Finished in colour of

choice

LAC ZA0109 1) 171,93

T = 330 Natural anodised ELO ZA0109 1) 137,92

Colour anodised BROMESDKS

SWZ

ZA0109 1) 208,77

Finished in colour of

choice

LAC ZA0109 1) 179,30

T = 360 Natural anodised ELO ZA0109 1) 146,42

Colour anodised BROMESDKSSWZ

ZA0109 1) 217,28

Finished in colour of

choice

LAC ZA0109 1) 190,35

T = 400 Natural anodised ELO ZA0109 1) 157,34

Colour anodised BRO

MESDKSSWZ

ZA0109 1) 228,62

Finished in colour of

choice

LAC ZA0109 1) 205,09

Natural anodised

Bronze

Dark silver

Brass

black

Page 33: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoAccessories

82 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Acc

esso

ries

1) Dimensions characteristic |MT| and ordering code need to be stated when ordering (for description, see chapter "General informati-on" and colour chart)

Top grilles

Ascotherm eco top grilles

Description

Product code Characteristic

Dimen-sions

Ordering code|MT|

Version

ProductVersion

Price

per metre

[EUR/m]Description

Orde-ring code

Flexible

aluminium

roll-up

grille

ZA0110

Dimensions• Length up to 5000 mm

– up to 3000 mm in one piece

– as of 3001 mm in two pieces

• Height 20 mm

• Bar width 6 mm

• Bar spacing 14 mm

– other spacings on request

• Open cross-section 70 %

Finish

• Anodised in natural or co-

lour, powder-coated in RAL

colours

• Anodised colours

– Natural (ELO)

– Bronze (BRO)

– Dark silver (DKS)

– Brass (MES)

– Black (SWZ)

• Cut surfaces in aluminium

colour if linear grille is in

two pieces

Version

• Anodised in natural colour

– Cross connections with

chrome steel springs and

PVC spacers in grey

• Anodised in colour

– Cross connections with

chrome steel springs and

PVC spacers in black

• Finished in colour of choice

– Cross connections with

chrome steel springs and

PVC spacers in black

Material

• Aluminium profiles

T = 185 Natural anodised ELO ZA0110 1) 90,92

Colour anodised BROMES

DKSSWZ

ZA0110 1) 161,76

Finished in colour of

choice

LAC ZA0110 1) 118,20

T = 210 Natural anodised ELO ZA0110 1) 95,65

Colour anodised BROMESDKS

SWZ

ZA0110 1) 166,50

Finished in colour of

choice

LAC ZA0110 1) 124,33

T = 260 Natural anodised ELO ZA0110 1) 108,63

Colour anodised BRO

MES

DKS

SWZ

ZA0110 1) 179,49

Finished in colour of

choice

LAC ZA0110 1) 141,22

T = 310 Natural anodised ELO ZA0110 1) 132,25

Colour anodised BROMES

DKS

SWZ

ZA0110 1) 203,10

Finished in colour of

choice

LAC ZA0110 1) 171,93

T = 330 Natural anodised ELO ZA0110 1) 137,92

Colour anodised BRO

MES

DKSSWZ

ZA0110 1) 208,77

Finished in colour of

choice

LAC ZA0110 1) 179,30

T = 360 Natural anodised ELO ZA0110 1) 146,42

Colour anodised BRO

MES

DKSSWZ

ZA0110 1) 217,28

Finished in colour of

choice

LAC ZA0110 1) 190,35

T = 400 Natural anodised ELO ZA0110 1) 157,34

Colour anodised BRO

MESDKS

SWZ

ZA0110 1) 228,62

Finished in colour of

choice

LAC ZA0110 1) 205,09

Natural anodised

Brass

Dark silver

black

Bronze

Page 34: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco Accessories

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 83

Acc

esso

ries

1) Dimensions characteristic |MT| and ordering code need to be stated when ordering (for description, see chapter "General informati-on" and colour chart)

Top grilles

Ascotherm eco top grilles

Description

Product code Characteristic

Dimen-sions

Ordering code|MT|

Version

ProductVersion

Price

per

metre

[EUR/m]]Description

Orde-ring code

Stainless

steel roll-

up grille

ZA0111

Dimensions• Length up to 5000 mm

– up to 3000 mm in one

piece– as of 3001 mm in two

pieces

• Height 20 mm

• Profile width 10 mm

• Profile spacing 16 mm

• Open cross-section 60 %

Version

• Cross connections with

chrome steel springs and PVC

spacers in grey

• Aluminium edge bar in stain-

less steel optic

Material

• Stainless steel

• Not to be used at tempe-

ratures below dew point

(danger of slipping)

T = 185 Stainless steel EDS ZA0111 1) 413,29

T = 210 Stainless steel EDS ZA0111 1) 448,70

T = 260 Stainless steel EDS ZA0111 1) 495,94

T = 310 Stainless steel EDS ZA0111 1) 543,17

T = 330 Stainless steel EDS ZA0111 1) 562,06

T = 360 Stainless steel EDS ZA0111 1) 590,40

T = 400 Stainless steel EDS ZA0111 1) 628,18

Wooden

roll-up

grille

ZA0112

Dimensions• Length up to 5000 mm

– up to 3000 mm in one

piece

– as of 3001 mm in two

pieces

• Height 20 mm

• Profile width 12 mm

• Profile spacing 16 mm

• Open cross-section 55 %

Version

• Light oak, ash and beech,

oiled

• Aluminium edge bar, natural

Material

• Cross connections with

chrome steel springs and PVC

spacers in white

• not to be used at tempe-

ratures below dew point

(material deformation)

T = 185 Oak

Ash

Beech

HEIHES

HBU

ZA0112 1) 271,49

T = 210 Oak

Ash

Beech

HEIHES

HBU

ZA0112 1) 307,01

T = 260 Oak

Ash

Beech

HEI

HES

HBU

ZA0112 1) 354,24

T = 310 Oak

Ash

Beech

HEI

HES

HBU

ZA0112 1) 401,48

T = 330 Oak

Ash

Beech

HEIHESHBU

ZA0112 1) 420,37

T = 360 Oak

Ash

Beech

HEIHES

HBU

ZA0112 1) 448,70

T = 400 Oak

Ash

Beech

HEI

HESHBU

ZA0112 1) 486,48

Beech

Stainless steel

Page 35: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoAccessories

84 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Acc

esso

ries

Accessories and miscellaneous

Accessories–fittings

Description

Product code Characteristic DimensionsProductVersion

Price [EUR]

Connection set,

straight form

ZV0110

• VE 5,5 (yellow), kv value 0,15

• Only for KRP91 / KRN92

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread with euro

taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread with euro

taper

– nickel-plated

– ZV0110 0001 41,16

• VE 2,5 (white), kv value 0,30

• Only for KRP91 / KRN92 / KRN81

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread with euro

taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread with euro

taper

– nickel-plated

– ZV0110 0002 41,16

• VE 4,5 (red), kv value 0,54

• Only for KRP91 / KRN92 / KRN81

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread with euro

taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread with euro

taper

– nickel-plated

– ZV0110 0003 41,16

• VE 6 (black), kv value 0,98

• Only for KRP91 / KRN 81 / KC2 81 / KC4 81

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread with euro

taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread with euro

taper

– nickel-plated

– ZV0110 0004 41,16

• VE 8 (blue), kv value 1,43

• Only for KRN 81 / KC2 81 / KC4 81

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread with euro

taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread with euro

taper

– nickel-plated

– ZV0110 0005 41,16

Page 36: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco Accessories

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 85

Acc

esso

ries

Accessories and miscellaneous

Connection set,

angled form

ZV0109

• VE 6 (black), kvs value 0,98

• Only for KC2 81 / KC4 81

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread with euro

taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread with euro

taper

– nickel-plated

– ZV0109 0001 41,16

• VE 8 (blue), kvs value 1,43

• Only for KC2 81 / KC4 81

Consisting of:

• Valve base with factory preset kv valve

– DN 15, both sides 3/4“ external thread with euro

taper

– M30 x 1,5

– nickel-plated, protective cap

• Return fitting with shut-off

– DN 15, both sides 3/4“ external thread with euro

taper

– nickel-plated

– ZV0109 0002 41,16

Flexible

connection

ZT0110

• Incl. 2 double nipples and seals for euro taper

• Corrugated hose , stainless steel, DN 16

• Operating pressure 10 bar

• Temperature resistance up to +90°C (briefly up to

+110°C)

• Nuts: brass, internal thread 3/4“, spanner opening 30

mm

• Seals: AFM 34

• Oxygen diffusion-proof

L = 300 mm ZT0110 0001 28,81

L = 500 mm ZT0110 0002 31,90

Double nipple

set

ZT0111 0001

• 2 pcs.

• 3/4“ external thread to 3/4“ external thread

– ZT0111 0001 5,66

Air-intake filter

ZK0077

• For KRN 81

• 1 roll (5 m)

• PPI 30 dark 90x3 mm, with hook & loop strips (1,5 m)

for installation

– ZK0077 0001 22,64

• For KC2 81 / KC4 81

• 1 roll (5 m)

• PPI 30 dark 140x3 mm, with hook & loop strips (2 m)

for installation

– ZK0077 0002 26,75

Plastic fitting

set

ZK0072

• Pipe penetration

• For installation in the pipe penetration of the floor

pan (suitable for pipe diameter up to 20 mm)

• 10 pcs.

– ZK0072 0001 14,41

• Cable penetration

• For installation in the cable penetration of the floor

pan

• 5 pcs.

– ZK0072 0002 10,29

Accessories–fittings

Description

Product code Characteristic

Dimensions

Ordering code|LAE|

ProductVersion

Price [EUR]

Page 37: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoAccessories

86 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Acc

esso

ries

Accessories and miscellaneous

Accessories-Control technique

Description

Product code Characteristic

Dimensions

Ordering code

|4|

ProductVersion

Ordering code

|3|

Price

[EUR]

Room thermo-

stat

ZE0077

• Programmable room thermostat, incl. fan control

• Only for KRN81 / KC281 / KC481

• Temperature control unit, incl. fan control with large

liquid crystal display (LCD) for controlling up to 6

trench convectors

• Energy-saving, automatic blue backlighting

• Programmable timer programs

• Temperature range 9°C to 32°C

• Settings 0,5°C

• Frost protection temperature 8°C

• Adjustable temperature offset +/5°C

• Control of heating/cooling

• Voltage supply via BUS cable

<• Output relay 5 A

• Protection type / protection class: IP30 / II

• Plastic casing 81x135x22 for wall mounting (with and

without in-wall pattress box)

• Colour similar to RAL9010

– ZE 0077 0003 125,54

• Digital room thermostat

• Only for KRP91 / KRN92

• Temperature control unit with digital temperature

display

• 3 operating modes

• Comfort and setback temperature adjustable from

5°C to 30°C

• Frost protection temperature adjustable from 5°C to

15°C

• Settings 0,5°C

• Adjustable temperature offset +/5°C

• Voltage supply via AAA batteries (2*1,5V)

• Battery charge display, battery change from the front

• Output relay 2 A

• Protection type / protection class: IP30 / II

• Plastic casing 80x80x23 for wall mounting (with and

without in-wall pattress box)

• Colour similar to RAL9010

– ZE 0077 0001 68,94

• Programmable room thermostat

• Only for KRP91 / KRN92

• Temperature control unit with large liquid crystal

display (LCD)

• Energy-saving, automatic blue backlighting

• Programmable timer programs

• 5 operating modes (comfort, set-back, frost protec-

tion, AUTO, Off)

• Week or day programming

• Voltage supply via AAA batteries (2*1,5V)

• Battery charge display, battery change from the front

without loss of program

• Output relay 2 A

• Protection type / protection class: IP30 / II

• Plastic casing 81x135x33 for wall mounting (with and

without in-wall pattress box)

• Colour similar to RAL9010

– ZE 0077 0002 107,02

KNX plug-in

card

ZE 0078 0001

• Only for KRN81 / KC281 / KC481

• For installation on the ASCOTHERM eco control board

to connect to KNX networks, only 1 card needed per

convector group (up to 6 convectors)

– ZE 0078 0001 139,94

Page 38: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco Accessories

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 87

Acc

esso

ries

Accessories and miscellaneous

Actuator

ZE 0087 0001

• Thermoelectric actuator 24 V DC

• Only for KRN 81 / KC2 81 / KC4 81

• Operating voltage 24 V DC

• Control voltage 0-10 V DC

• Power consumption 2 W

• Current draw 80 mA

• Inrush current max. 350 mA (max 2 min)

• Protection type / protection class: IP 54 / III

• Operating displacement 4 mm

• Incl. VA80 valve adapter and 5 m connecting line

• Currentless closed

– ZE 0087 0001 87,47

Actuator

ZE 0023 0001

• Thermoelectric actuator 230 V AC

• Only for KRP91 / KRN 92

• Operating voltage 230 V AC, 50/60 Hz

• Power consumption 1 W

• Inrush current max. 320 mA

• Protection type / protection class: IP54 / II

• Humidity max 80% non-condensing

• Currentless closed

– ZE 0023 0001 29,84

Thermostat

with fine

adjustment

ZV0081 0001

• Only for KRP91 / KRN 92

• Threaded connection M30 x 1,5

• Capillary pipe 5 m long

• casing, white

• Temperature range 7 °C to 28 °C

• Scaled cap

– 0 Frost protection

– 1 - 5

• When a thermostat with remote control is used, other

kv settings are needed for the valves; the valve inserts

are preset for use with actuators as standard

– ZV0081 0001 94,67

External room

temperature

sensor

ZE 0080 0001

• Room temperature sensor NTC 10 K with plastic cap,

incl. 3-m cable + installation material

– ZE 0080 0001 31,90

Pipe surface

sensor

ZE0081

• For sensing the flow temperatures, incl. 2-m cable +

installation material, for lengths up to 2000 mm

– ZE 0081 0001 36,02

• For sensing the flow temperatures, incl. 4-m cable +

installation material, for lengths over 2000 mm

– ZE 0081 0002 39,10

Dew point

monitor

ZE 0082 0001

• Supply voltage 24 V DC

• Current draw max. 3 mA

• Range 10% to 100% relative humidity

• Switching point at 20°C: 90 +/ 3% relative humidity

• Reaction time on change of pipe temperature:

t90 < 3 min.

• Reaction time on change of room humidity: t90 < 25

sec.

• Incl. cable penetration and circuit board plug

– ZE 0082 0001 143,03

Window

contact sensor

ZE00830001

• Voltage supply 1 lithium battery 3 V, type CR2032,

service life up to 2 years

• Transmission type X2D protocol

• Radio frequency 868 MHz

• Transmission range up to 300 m (in open area)

• Protection type IP 40

• Casing ABS/PC

– ZE 0083 0001 81,29

Accessories-Control technique

Description

Product code Characteristic

Dimensions

Ordering code

|4|

ProductVersion

Ordering code

|3|

Price

[EUR]

Page 39: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoAccessories

88 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Acc

esso

ries

Accessories and miscellaneous

Assembling aids

Description

Product code Characteristic

Dimensions

Ordering code

|4|

Surface /

Finish

Ordering code|17|

Product

Version

Ordering code

|3|Price[EUR]

Spray paint

ZK0002 0007

• RAL 7016 (matt) – Anthracite ZK0002 0007 16,98

Presence

detector

ZE00840001

• Voltage supply 230 V with phase and neutral conduc-

tor

• Radio frequency 868 MHz

• 1 to 2 control channels, depending on function

• 3 pre-installed cable for connection to the local

switch, button for up/down

• 1 wired phase input from sensor or button

• Up to 16 bidirectional RF receivers and any number of

unidirectional RF receivers

• Operating temperature -5°C to 40°C

• Dimensions: H 50 x B 47 x T 23 mm

– ZE 0084 0001 121,42

RF receiver

ZE 0085 0001

• For use with window contact sensor and presence

detector

• Voltage supply via control board

• Up to 2x20 transmitters applicable

• Transmission range up to 100 m (open area)

• Incl. 1-m cable + installation material

– ZE 0085 0001 183,16

Cable

ZE 0086 0001

• For use with RF receiver (ZE00850001)

• Length 2 m

– ZE 0086 0001 12,35

Accessories-Control technique

Description

Product code Characteristic

Dimensions

Ordering code

|4|

ProductVersion

Ordering code

|3|

Price

[EUR]

Page 40: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoFurther information

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 89

Furt

her

info

rmat

ion

Size and units of measurement

Size and units of measurement

Description Code Units

metre [m]

Millimetre [mm]

Kilogramme [kg]

Degree Celsius [°C]

Kelvin [K]

Joule [J]

Second [s]

Hour [h]

Pascal, kilopascal [Pa, kPa]

Length, height, depth L, H, T [mm]

Floor pan length Lfloor pan [mm]

Ribbed convector length Lribb. [mm]

floor pan height Hfloor pan [mm]

Register height Hreg. [mm]

floor pan depth Tfloor pan [mm]

Register depth Treg. [mm]

Mass M [kg]

Flow-, return temperature t1, t2 [°C]

Room temperature tr [°C]

Mean hot water temperature tm [°C]

Volume flow rate V [m3/h]

Velocity v [m/s]

Pressure loss ∆p [mbar]

Valve coefficient kV

Adjustable valve coefficient kVS

Operating pressure, test pressure, air pressure p [bar/Pa]

Sound pressure level Lp [dB/A]

Acoustic power level LW [dB/A]

Internal thread IG –

External thread AG –

1) Maximum length: greatest possible length of a delivery unit

Page 41: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoFurther information

90 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Furt

her

info

r-m

atio

n

Size and units of measurement

Size and units of measurement for heating

Description Code Units

Average heat transfer medium temperature EN 442 tm = t1 + t2

2[°C]

Over temperature ∆T [K]

Standard over temperature ΔTn = 49,83 K [K]

Heat output (Phi) Φ [W]

Standard heat output at 75 / 65 / 20 °C (∆T 50 K) (EN 442) Φs [W]

Specific standard heat output ΦL [W/m]

Specific heat capacity cp [J/kgK]

Radiator classification, exponent n –

Correction factor CK –

Water flow rate, standard water flow rate in accordance with

EN 442qm [kg/h]

spec. standard water flow rate according to EN 442 qms [kg/h m]

Size and units of measurement for cooling

Description Code Units

Mean cooling water temperature tm = t1 + t2

2[°C]

Under temperature difference ∆T [K]

Standard under temperature ∆Tn = 9,97 K [K]

Total cooling capacity PK [W]

Total standard cooling capacity PKN [W]

Sensible cooling capacity PS [W]

Sensible standard cooling capacity PSN [W]

Specific heat capacity cp [J/kgK]

Classification, exponent n –

Correction factor CK –

Water flow rate, standard water flow rate in accordance with

EN 442qm [kg/h]

spec. water flow, spec. standard water flow rate according to EN 442

qms [kg/h m]

Relative humidity ϕ [%]

Page 42: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco Further information

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 91

Furt

her

info

rmat

ion

Planning, assembly and installation information

Preliminary notes

General

Goods and services are provided exclusively on the basis of our

General Terms of Sale, Delivery and Payment.

Technical data

The respective technical data refer to the standard version.

Subject to changes and tolerances customary in the industry or

necessary for production reasons.

Operating conditions

• For closed hot water heating systems in accordance with DIN

18380 and water quality in accordance with VDI 2035.

• Ascotherm eco trench convectors are not suitable for steam

heating systems.

KRP91, KRN92

Company relevant

characteristics

Standard

version

High-pressure

version

Operating pressure [bar

(kPa)]10,0 (1000) 16,0 (1600)

Test pressure [bar (kPa)] 13,0 (1300) 20,8 (2080)

Max. temperature [°C] 110 110

KRN81, KC281, KC481

Company relevant

characteristics

Standard

version

High-pressure

version

Operating pressure [bar

(kPa)]10,0 (1000) 16,0 (1600)

Test pressure [bar (kPa)] 13,0 (1300) 20,8 (2080)

Max. temperature [°C] 90 90

Unless an operating pressure is specified, the standard version

will be provided.

Water quality

Operating conditions for water quality in accordance with VDI

2035 must be maintained just as the industry-standard installati-

on rules.

Warranty claims according to our General Terms of Sale, Delivery

and Payment shall be invalid in the event of:

• periodic or extended draining of the system

• operation with steam

• addition of substances (e.g. chemicals, antifreeze) to the

heating water that can have a corrosive effect on copper or

sealing materials

• excessive sludge deposition in the trench convector

• occasional or constant drag-in of oxygen into the system (e.g.

lines and pipes that are not sealed against diffusion)

• leaks in the heating system

Special versions according to drawings

If necessary, the customer receives a dimensional drawing for

review and approval; the order will be produced after this is

returned. In the event that the order is cancelled, the customer

must pay compensation for the services and costs incurred up to

that point.

Paint finishes

Stoved enamel powder coating (packaged) in all RAL colours

according to customer specifications; colour deviations customary

in the industry are possible.

Use only original RAL colour samples for colour matching.

For production reasons, paint finishes are subject to slight colour

deviations, caused in part by specific light conditions. There

may also be differences when comparing painted surfaces with

painted ceramic products. Because of limitations in the printing

process, the illustrated colours are not binding.

The floor pans and possibly aluminium grilles are finished in

accordance with DIN 55900. They must be transported with care

and protected against damage at the construction site.

Noises

Noise emission depends on the design, size and fan speed. The

acoustic power levels were measured using DIN 45635-1 as a

reference.

According to E DIN EN 16430-1 (Fan-assisted radiators, convectors

and trench convectors - Part 1: Technical specifications and requi-

rements), the sound pressure level can be defined with a room

absorption of 8 dB(A). This corresponds to a distance of 2 m from

the tested unit, a room volume of 100 m3 and a reverberation

time of 0,5 s.

The acoustic characteristics of the room influence the noise level.

Accordingly, the actual values may differ. It is recommended that

the Ascotherm eco be designed for operation at a moderate

speed.

Page 43: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoFurther information

92 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Furt

her

info

r-m

atio

n

Planning, assembly and installation information

Acoustic

Sources of noise cause the air to oscillate; it compresses and

expands alternately.

These pressure changes dither the existing air pressure and pro-

pagated through the air in sinusoidal form. When these pressure

fluctuations reach our ear, the air pressure waves are transfor-

med into mechanical vibrations by the eardrum.

The process of hearing is begun.

The human ear only senses the airborne sound; the following

two factors are decisive:

a: Sound pressure

b: Frequency

1. Sound pressure

The sound pressure is the change in pressure of the air caused by

a sound source. These pressure fluctuations are measured in N/

m², and are designated with the letter p.

The sound pressure is a measure of the sound level. It depends

on the distance between the sound source and the measurement

location as well as the properties of the room.

The sound pressure is unsuitable for calculating the expansion of

sound on the sound propagation paths. For this it is necessary to

determine the acoustic power of the sound source.

2. Acoustic power

The energy converted into sound by a component (sound source)

is called acoustic power. This acoustic power is transmitted to the

air in the form of pressure fluctuations.

The acoustic power is a value that cannot be measured directly. It

is determined by integrating the acoustic pressure over a hemis-

pherical or spherical surface about the sound source.

The acoustic power is thus a value that is independent of space

and distance.

It will be used for all of the following calculations.

The acoustic power is stated in watt [W].

For practical use, dimensionless figures have been introduced

based on the work of A. G. Bell.

3. Sound pressure level

The logarithmic relationship of a sound pressure p to the refe-

rence value p0 is designated acoustic pressure level LP; the unit

used to specify it is the decibel [dB].

Lp = 10 lg ( p )2

p0

p = Effective value of the sound pressure at a certain

spot in the room

p0 = Reference sound pressure, specified internationally at 2 x

10-5 N/m²

4. Acoustic power level

The acoustic power level LW is defined by:

LW = 10 lg ( P ) in dBP0

P = Acoustic power in watts

P0 = Reference power, specify internationally at 1 x 10-12 watts

The sound pressure level is the sound generated at the sound

source (the energy transmitted to the air), while the acoustic

pressure level is the sound registered at a certain distance from

the sound source.

Thus generally the acoustic power level is larger than the

acoustic pressure level.

5. Frequency assessment

Humans perceive the same sound pressure level differently at dif-

ferent frequencies. A sound pressure level is generally perceived

as quieter and less annoying at low frequencies than at higher

frequencies.

In order to take this subjective perception into account, the

objectively measured sound pressure levels are adapted to the

perception of sound levels. This is called assessment of the sound

pressure level.

This assessment is done by subtracting a certain amount from

the measured sound pressure level for frequencies that humans

are less sensitive to, while adding a certain amount in the other

frequency ranges.

Of the various assessments, the A-weighting has become virtually

the only one used.

This provides information in the form of a single figure that is

designated as an A-weighted acoustic pressure level or an A-

weighted sound pressure power.

The unit is called db[A].

6. Sound level additions

If several sound sources are present, then the corresponding

levels have to be added to form a total sound level.

The same principles apply here for both the sound pressure level

and the acoustic power level.

When there is more than one sound source with the same level,

the following relationship applies:

Ltot = L1 + 10 x log n [dB]

Page 44: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 93

Furt

her

info

rmat

ion

Planning, assembly and installation information

Ascotherm® eco Further information

Calculation: General informationCalculation of the heating requirements of buildings is perfor-

med according to the standard DIN EN 12831.

Basic principles heat outputsThe heat outputs of Ascotherm eco trench convectors were

measured and established in accordance with E DIN EN 16430

"Fan-assisted radiators, convectors and trench convectors" Part

1: "Technical specifications and requirements" and Part 2 "Test

method and rating for thermal output".

Standard heat output ΦS (∆T = 50 K)

The standard heat output ΦS in watts of a radiator indicates the

heat flow that is emitted under the following conditions:

- Flow temperature t1 = 75 °C

- Return temperature t2 = 65 °C

- Room temperature tr = 20 °C

- Air pressure p = 1013 hPa

From this follows the average heating water temperature tm in

°C.

tr

t1 t2

tm

tm =t1 + t2

=75 + 65

= 70 °C2 2

Calculation

Heat output Φ (deviation from ∆T = 50 K)

For over temperature ∆T deviating from ∆T = 50 K, the heat out-

put is calculated as follows:

Φ = ΦS x∆T

n

or Φ = ΦS x CK∆Tn

where n = exponent and CK = correction factor of the heat

output characteristic curve (see technical data of the radiators).

The over temperature ∆T should be calculated logarithmically as

follows:

∆T =(t1 - tr) - (t2 - tr)

=(t1 - t2)

ln(t1 - tr)

ln(t1 - tr)

(t2 - tr) (t2 - tr)

The over temperature ∆T for normal conditions (75 / 65 / 20 °C) is

the following as a logarithmic over temperature :

∆Tn =75- 65

= 49.83 K

ln75 - 20

65 - 20

Calculation example

KRP91 with L = 3000 mm; H = 120 mm; T = 260 mm

Ascotherm eco:

- Standard heat output ΦS = 1288 watts

- Exponent n = 1,43

Operating conditions:

- Flow temperature t1 = 65 °C

- Return temperature t2 = 50 °C

- Room temperature tr = 20 °C

∆T =65 - 50

=15

=15

=15

= 36,99 K

ln65 - 20

ln45 ln1,5 0,4055

50 - 20 30

Φ = ΦS x CK = 1089 x

36,991,43

= 1288 x 0,653 = 841 W49,83

Page 45: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

94 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Furt

her

info

r-m

atio

n

Planning, assembly and installation information

Ascotherm® ecoFurther information

Water flow

Minimum water flow rate

In order to guarantee even temperature distribution in the radi-

ator and thus proper heat emission, a minimum water flow must

be assured.

For each version, the specific standard water flow rate qms is

stated in the performance tables.

The water flow is calculated as follows:

qm [kg/h] =Φ

1,16 x (t1 - t2)

Calculation example

KRP91 with L = 3000 mm; H = 110 mm; T = 260 mm

Φs = 1288 W t1 = 75 °C t2 = 65 °C tr = 20 °C

qm =1288 W

= 111,0 kg/h 1,16 x (75-65)

Calculation example

Φ = 841 W t1 = 65 °C t2 = 50 °C tr = 20 °C

qm =841 W

= 48,3 kg/h 1.16 x (65-50)

Simplified dimensioning

Calculation:

1) Take exponent from table

2) Determine over temperature

3) Determine factor CK from the correction factor table

4) Calculate standard heat output as follows:

Φs =Φ desired

CK

5) Compare calculated value ΦS with table value Φ ∆T 50 K and

select corresponding version

Example:

- Flow temperature t1 = 65 °C

- Return temperature t2 = 55 °C

- Room temperature tr = 20 °C

- Desired heat output Φ = 1800 W

- Maximum dimensions L = 4500 mm

H = 200 mm

T = 360 m

1) n = 1,37

2) Over temperature at 65/55/20 °C = 39,8 K ∼ 40 K

3) Factor CK 65/55/20 = 0,7400

4)

Φs =Φ desired

=1800 W

= 2432 WCk 0,7400

5) KRP91 with

L = 4250 mm, H = 150 mm, T = 260 mm,

ΦS = 2575 W ≥ 2432 W

or

KRP91 with

L = 3250 mm, H = 200 mm, T = 310 mm,

ΦS = 2520 W ≥ 2432 W

Page 46: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 95

Furt

her

info

rmat

ion

Planning, assembly and installation information, cooling outputs

Ascotherm® eco Further information

Calculation: General informationThe cooling load of buildings is calculated on the basis of

VDI 2078.

Basic principles, cooling outputsThe cooling outputs of Ascotherm eco trench convectors were

measured and established in accordance with E DIN EN 16430

"Fan-assisted radiators, convectors and trench convectors" Part

1: "Technical specifications and requirements" and Part 3 "Test

method and rating for cooling outputs".

Standard cooling output PKN (∆T = 10 K)

The cold air flow generated under the following conditions is

designated the total standard cooling output PKN in watts of an

Ascotherm eco:

t1 [°C] = Cool water inflow t1 = 16 °C

t2 [°C] = Cool water outflow t2 = 18 °C

tr [°C] = Room temperature tr = 27 °C

Air pressure p = 1013 hPa

Relative humidity ϕ = 50 %

This produces the average cooling water temperature tm in °C.

tm =t1 + t2

=16 + 18

= 17 °C2 2

Calculation

Cooling output PK (when deviating from ∆T = 10 K)

For temperature loss ∆T that deviate from ∆T = 10 K, the cooling

output is calculated as follows:

PK = PKN x∆T

n

or PK = PKN x CK∆Tn

where n = exponent and CK = correction factor of the heat out-

put characteristic (see technical data). The temperature diffe-

rence ∆T should be calculated logarithmically as follows:

∆T =(t1 - tr) - (t2 - tr)

=(t1 - t2)

ln(t1 - tr)

ln(t1 - tr)

(t2 - tr) (t2 - tr)

The under temperature ∆T under standard conditions (16 / 18 / 27

°C) corresponds to the following logarithmic under temperature :

∆Tn =16- 18

= 9,97 K

ln16 - 27

18 - 27

Calculation example

KC281 with L = 2000 mm; H = 130 mm; T = 310 mm

Ascotherm eco:

- Total standard cooling

output

PKN = 882 watts

- Exponent n = 1,00

- Control voltage 5 V

Operating conditions:

- Flow temperature t1 = 17 °C

- Return temperature t2 = 19 °C

- Room temperature tr = 26 °C

∆T =17 - 19

=2

=2

=2

= 7,96 K

ln17 - 26

ln9 ln1,29 0,2513

19 - 26 7

PK = PKN x CK = 882 x

7,961,00

= 882 x 0,7984 = 704 W9,97

Page 47: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

96 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Furt

her

info

r-m

atio

n

Planning, assembly and installation information, cooling outputs

Ascotherm® ecoFurther information

Water flowFormula for calculating the water flow qm.

qm [kg/h] = PK [W]

1,16 (t2 - t1)

For each version<, the specific standard water flow rate qms is

stated in the performance tables.

Calculation example

KC281 with L = 2000 mm, H = 130 mm, T = 310 mm

PKN = 882 W t1 = 16 °C<t2 = 18

°Ctr = 27 °C

qm =882 W

= 380 kg/h 1,16 x (18-16)

Calculation example

PK = 704 W t1 = 17 °C t2 = 19 °C tr = 26 °C

qm =704 W

= 303,45 kg/h 1,16 x (19-17)

Simplified dimensioning

Calculation:

1) Take exponent from table

For approximate calculation n = 1,00

2) Determine under temperature

3) Determine factor CK from the correction factor table

4) Calculate standard cooling output as follows:

PKN =Pdesired

CK

5) Compare calculated value PKN with table value and select

appropriate version

Example:

- Flow temperature t1 = 17 °C

- Return temperature t2 = 19 °C

- Room temperature tr = 26 °C

- Desired cooling output Pdesired = 1000 W

- Desired version KC 281

- Maximum dimensions L = 2000 mm

H = 155 mm

T = 360 m

1) n = 1,00

2) Under temperature at 17/19/26 °C = 7,96 K ∼ 8 K

3) Factor CK 17/19/26 = 0,8024

4)

PKN=Pdesired

=1000 W

= 1246 WCk 0,8024

5) KC281 with

L = 2000 mm, H = 155 mm, T = 360 mm,

Dimensioning with control voltage of 5 V

PKN = 1256 W ≥ 1246 W

or

KC281 with

L = 2000 mm, H = 130 mm, T = 310 mm,

Dimensioning with control voltage of 7 V

PKN = 1336 W ≥ 1246 W

Note regarding "Basics of cooling outputs":

The calculations above are for a dimensioning with dry cooling.

If system parameters that result in condensation on the cooling

register are intentionally selected during planning, the sensible

cooling output needs to be considered in addition to the total

cooling output. In this case, the sensible cooling output is the

determining factor for performance the cooling load.

Page 48: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 97

Furt

her

info

rmat

ion

Planning, assembly and installation information, cooling outputs

Ascotherm® eco Further information

Air tempera-

ture

[°C]

Dew point temperature in °C at a relative humidity of

10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

5 -24,0 -15,9 -11,2 -7,6 -4,6 -2,2 -0,1 +1,8 +3,5 +5,0

6 -23,1 -15,0 -10,3 -6,6 -3,7 -1,3 +0,8 +2,8 +4,5 +6,0

7 -22,3 -14,2 -9,4 -5,7 -2,8 -0,4 +1,8 +3,8 +5,5 +7,0

8 -21,6 -13,5 -8,5 -4,8 -1,8 +0,6 +2,8 +4,8 +6,5 +8,0

9 -21,0 -12,8 -7,6 -3,8 -0,8 +1,6 +3,8 +5,8 +7,4 +9,0

10 -20,2 -12,0 -6,7 -2,9 +0,1 +2,5 +4,8 +6,8 +8,4 +10,0

11 -19,5 -11,1 -5,9 -2,0 +0,9 +3,5 +5,7 +7,8 +9,4 +11,0

12 -18,7 -10,2 -5,0 -1,2 +1,7 +4,4 +6,6 +8,7 +10,4 +12,0

13 -17,9 -9,4 -4,2 -0,3 +2,6 +5,3 +7,5 +9,7 +11,4 +13,0

14 -17,2 -8,6 -3,3 +0,6 +3,5 +6,2 +8,5 +10,6 +12,3 +14,0

15 -16,5 -7,8 -2,4 +1,5 +4,5 +7,2 +9,5 +11,6 +13,3 +15,0

16 -15,7 -6,9 -1,5 +2,4 +5,5 +8,1 +10,5 +12,6 +14,3 +16,0

17 -14,9 -6,0 -0,7 +3,3 +6,5 +9,1 +11,5 +13,5 +15,3 +17,0

18 -14,1 -5,2 +0,2 +4,2 +7,4 +10,1 +12,4 +14,5 +16,3 +18,0

19 -13,2 -4,5 +1,0 +5,1 +8,3 +11,0 +13,4 +15,4 +17,3 +19,0

20 -12,5 -3,6 +1,9 +6,0 +9,3 +12,0 +14,3 +16,4 +18,3 +20,0

21 -11,7 -2,8 +2,7 +6,8 +10,2 +12,9 +15,3 +17,4 +19,3 +21,0

22 -11,0 -2,0 +3,6 +7,7 +11,1 +13,9 +16,3 +18,3 +20,3 +22,0

23 -10,3 -1,2 +4,5 +8,6 +12,1 +14,7 +17,2 +19,3 +21,2 +23,0

24 -9,6 -0,3 +5,4 +9,5 +12,9 +15,7 +18,2 +20,3 +22,2 +24,0

25 -8,8 +0,5 +6,3 +10,4 +13,8 +16,7 +19,2 +21,3 +23,2 +25,0

26 -8,0 +1,3 +7,1 +11,3 +14,8 +17,7 +20,2 +22,3 +24,2 +26,0

27 -7,3 +2,1 +7,9 +12,2 +15,8 +18,5 +21,0 +23,2 +25,2 +27,0

28 -6,5 +3,0 +8,7 +13,1 +16,7 +19,5 +22,0 +24,2 +26,2 +28,0

29 -5,7 +3,8 +9,6 +14,0 +17,5 +20,4 +23,0 +25,2 +27,2 +29,0

30 -5,0 +4,6 +10,5 +14,9 +18,4 +21,4 +24,0 +26,2 +28,2 +30,0

Example of system dimensioning under normal conditions

Dew point tableFor a correct dry cooling dimensioning without condensation,

the flow temperature of the cool water needs to be taken into

account. The flow temperature of the cooling water can be

taken as the lowest possible surface temperature of fin compon-

ents. Assuming normal conditions (room air temperature 27 °C,

relative humidity 50%), the

dew point will be 15.8 °C. This means that condensation can be

expected if the flow temperature of the cool water drops below

15.8 °C. Beneficial drying effects associated with fan operation

are not taken into account, since this effect depends largely on

the fan speed.

Page 49: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

98 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Furt

her

info

r-m

atio

n

Planning, assembly and installation information

Ascotherm® ecoFurther information

Over temperatures ∆T (logarithmic calculation)

Flow

temperature

t1 °C

Room

temperature

tr °C

Return temperature t2 °C

30 35 40 45 50 55 60 65 70 75

90 24 30,7 35,3 39,3 42,9 46,3 49,5 52,5 55,4 58,2

22 33,2 37,6 41,5 45,1 48,4 51,6 54,5 57,4 60,2

20 30,8 35,7 39,9 43,7 47,2 50,5 53,6 56,6 59,4 62,2

18 33,5 38,1 42,2 45,9 49,3 52,6 55,7 58,6 61,5 64,2

15 37,3 41,6 45,5 49,1 52,5 55,7 58,7 61,7 64,5 67,2

85 24 29,2 33,6 37,5 41,0 44,3 47,4 50,3 53,1 55,9

22 31,7 35,9 39,7 43,2 46,4 49,5 52,4 55,2 57,9

20 29,4 34,1 38,2 41,9 45,3 48,5 51,5 54,4 57,2 59,9

18 32,0 36,5 40,4 44,0 47,4 50,5 53,5 56,4 59,2 61,9

15 35,7 39,9 43,7 47,2 50,5 53,6 56,6 59,4 62,2 64,9

80 24 27,7 31,9 35,7 39,1 42,3 45,3 48,1 50,8 53,5

22 30,1 34,2 37,8 41,2 44,3 47,3 50,1 52,8 55,5

20 27,9 32,5 36,4 40,0 43,3 46,4 49,3 52,1 54,8 57,5

18 30,4 34,8 38,6 42,1 45,4 48,4 51,4 54,2 56,9 59,5

15 34,1 38,2 41,9 45,3 48,5 51,5 54,4 57,2 59,9 62,5

75 24 26,1 30,2 33,8 37,1 40,2 43,1 45,8 48,5

22 28,5 32,4 35,9 39,2 42,2 45,1 47,8 50,5

20 26,4 30,8 34,6 38,0 41,2 44,2 47,1 49,8 52,5

18 28,9 33,1 36,8 40,1 43,3 46,3 49,1 51,8 54,5

15 32,5 36,4 40,0 43,3 46,4 49,3 52,1 54,8 57,5

70 24 24,5 28,4 31,9 35,1 38,0 40,8 43,5

22 26,8 30,6 34,0 37,1 40,0 42,8 45,5

20 24,9 29,1 32,7 36,1 39,2 42,1 44,8 47,5

18 27,3 31,3 34,9 38,1 41,2 44,1 46,8 49,5

15 30,8 34,6 38,0 41,2 44,2 47,1 49,8 52,5

65 24 22,8 26,6 29,9 32,9 35,8 38,4

22 25,1 28,7 32,0 35,0 37,8 40,4

20 23,3 27,3 30,8 34,0 37,0 39,8 42,5

18 25,6 29,5 32,9 36,1 39,0 41,8 44,5

15 29,1 32,7 36,1 39,2 42,1 44,8 47,5

60 24 21,1 24,7 27,8 30,7 33,4

22 23,3 26,8 29,9 32,7 35,4

20 21,6 25,5 28,9 31,9 34,8 37,4

18 23,9 27,6 30,9 33,9 36,8 39,4

15 27,3 30,8 34,0 37,0 39,8 42,5

55 24 19,3 22,7 25,7 28,4

22 21,5 24,7 27,7 30,4

20 20,0 23,6 26,8 29,7 32,4

18 22,2 25,7 28,9 31,7 34,4

15 25,5 28,9 31,9 34,8 37,4

50 24 17,4 20,6 23,4

22 19,6 22,6 25,4

20 18,2 21,6 24,7 27,4

18 20,4 23,7 26,7 29,4

15 23,6 26,8 29,7 32,4

45 24 15,5 18,4

22 17,5 20,4

20 16,4 19,6 22,4

18 18,5 21,6 24,4

15 21,6 24,7 27,4

Page 50: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 99

Furt

her

info

rmat

ion

Planning, assembly and installation information, heat output correction factors

Ascotherm® eco Further information

Correction factors CK (logarithmic calculation)

∆T [K]Exponent n

∆T [K]1,00 1,28 1,29 1,30 1,31 1,32 1,33 1,34 1,35 1,36 1,37 1,38 1,39

10 0,2007 0,1280 0,1260 0,1239 0,1220 0,1200 0,1181 0,1162 0,1144 0,1126 0,1108 0,1090 0,1073 10

11 0,2207 0,1446 0,1424 0,1403 0,1382 0,1361 0,1341 0,1321 0,1301 0,1281 0,1262 0,1243 0,1225 11

12 0,2408 0,1616 0,1593 0,1571 0,1549 0,1527 0,1505 0,1484 0,1463 0,1442 0,1422 0,1402 0,1382 12

13 0,2609 0,1791 0,1767 0,1743 0,1720 0,1697 0,1674 0,1652 0,1630 0,1608 0,1587 0,1566 0,1545 13

14 0,2809 0,1969 0,1944 0,1920 0,1895 0,1871 0,1848 0,1824 0,1801 0,1779 0,1756 0,1734 0,1712 14

15 0,3010 0,2151 0,2125 0,2100 0,2075 0,2050 0,2025 0,2001 0,1977 0,1954 0,1930 0,1907 0,1885 15

16 0,3211 0,2336 0,2310 0,2283 0,2258 0,2232 0,2207 0,2182 0,2157 0,2133 0,2109 0,2085 0,2061 16

17 0,3411 0,2524 0,2497 0,2471 0,2444 0,2418 0,2392 0,2367 0,2341 0,2316 0,2291 0,2267 0,2243 17

18 0,3612 0,2716 0,2688 0,2661 0,2634 0,2608 0,2581 0,2555 0,2529 0,2504 0,2478 0,2453 0,2428 18

19 0,3813 0,2911 0,2883 0,2855 0,2828 0,2800 0,2774 0,2747 0,2721 0,2695 0,2669 0,2643 0,2618 19

20 0,4013 0,3108 0,3080 0,3052 0,3024 0,2997 0,2969 0,2942 0,2916 0,2889 0,2863 0,2837 0,2811 20

21 0,4214 0,3308 0,3280 0,3252 0,3224 0,3196 0,3169 0,3141 0,3114 0,3087 0,3061 0,3035 0,3008 21

22 0,4415 0,3511 0,3483 0,3454 0,3426 0,3398 0,3371 0,3343 0,3316 0,3289 0,3262 0,3236 0,3209 22

23 0,4615 0,3717 0,3688 0,3660 0,3632 0,3604 0,3576 0,3548 0,3521 0,3494 0,3467 0,3440 0,3414 23

24 0,4816 0,3925 0,3897 0,3868 0,3840 0,3812 0,3784 0,3757 0,3729 0,3702 0,3675 0,3649 0,3622 24

25 0,5017 0,4136 0,4107 0,4079 0,4051 0,4023 0,3995 0,3968 0,3941 0,3914 0,3887 0,3860 0,3833 25

26 0,5217 0,4349 0,4320 0,4292 0,4265 0,4237 0,4209 0,4182 0,4155 0,4128 0,4101 0,4075 0,4048 26

27 0,5418 0,4564 0,4536 0,4508 0,4481 0,4453 0,4426 0,4399 0,4372 0,4345 0,4319 0,4292 0,4266 27

28 0,5619 0,4781 0,4754 0,4726 0,4699 0,4672 0,4645 0,4619 0,4592 0,4566 0,4540 0,4513 0,4487 28

29 0,5819 0,5001 0,4974 0,4947 0,4920 0,4894 0,4867 0,4841 0,4815 0,4789 0,4763 0,4737 0,4712 29

30 0,6020 0,5223 0,5196 0,5170 0,5144 0,5118 0,5092 0,5066 0,5040 0,5015 0,4990 0,4964 0,4939 30

31 0,6221 0,5447 0,5421 0,5395 0,5370 0,5344 0,5319 0,5294 0,5269 0,5244 0,5219 0,5194 0,5169 31

32 0,6421 0,5672 0,5647 0,5622 0,5598 0,5573 0,5548 0,5524 0,5499 0,5475 0,5451 0,5427 0,5403 32

33 0,6622 0,5900 0,5876 0,5852 0,5828 0,5804 0,5780 0,5756 0,5733 0,5709 0,5685 0,5662 0,5639 33

34 0,6823 0,6130 0,6107 0,6083 0,6060 0,6037 0,6014 0,5991 0,5968 0,5946 0,5923 0,5900 0,5878 34

35 0,7023 0,6362 0,6339 0,6317 0,6295 0,6273 0,6250 0,6228 0,6206 0,6185 0,6163 0,6141 0,6119 35

36 0,7224 0,6595 0,6574 0,6553 0,6531 0,6510 0,6489 0,6468 0,6447 0,6426 0,6405 0,6384 0,6364 36

37 0,7425 0,6831 0,6811 0,6790 0,6770 0,6750 0,6730 0,6710 0,6690 0,6670 0,6650 0,6630 0,6611 37

38 0,7625 0,7068 0,7049 0,7030 0,7011 0,6992 0,6973 0,6954 0,6935 0,6916 0,6898 0,6879 0,6860 38

39 0,7826 0,7307 0,7289 0,7271 0,7254 0,7236 0,7218 0,7200 0,7183 0,7165 0,7148 0,7130 0,7113 39

40 0,8027 0,7548 0,7531 0,7515 0,7498 0,7482 0,7465 0,7449 0,7432 0,7416 0,7400 0,7384 0,7367 40

41 0,8227 0,7790 0,7775 0,7760 0,7745 0,7730 0,7714 0,7699 0,7684 0,7669 0,7655 0,7640 0,7625 41

42 0,8428 0,8034 0,8020 0,8007 0,7993 0,7979 0,7966 0,7952 0,7939 0,7925 0,7911 0,7898 0,7884 42

43 0,8629 0,8280 0,8268 0,8255 0,8243 0,8231 0,8219 0,8207 0,8195 0,8183 0,8171 0,8159 0,8147 43

44 0,8830 0,8527 0,8516 0,8506 0,8495 0,8485 0,8474 0,8464 0,8453 0,8443 0,8432 0,8422 0,8411 44

45 0,9030 0,8776 0,8767 0,8758 0,8749 0,8740 0,8731 0,8722 0,8713 0,8705 0,8696 0,8687 0,8678 45

46 0,9231 0,9026 0,9019 0,9012 0,9005 0,8997 0,8990 0,8983 0,8976 0,8969 0,8962 0,8954 0,8947 46

47 0,9432 0,9278 0,9273 0,9267 0,9262 0,9257 0,9251 0,9246 0,9240 0,9235 0,9229 0,9224 0,9219 47

48 0,9632 0,9532 0,9528 0,9525 0,9521 0,9517 0,9514 0,9510 0,9507 0,9503 0,9500 0,9496 0,9492 48

49 0,9833 0,9787 0,9785 0,9783 0,9782 0,9780 0,9778 0,9777 0,9775 0,9773 0,9772 0,9770 0,9768 49

50 1,0034 1,0043 1,0043 1,0044 1,0044 1,0044 1,0045 1,0045 1,0045 1,0046 1,0046 1,0046 1,0047 50

51 1,0234 1,0301 1,0303 1,0306 1,0308 1,0310 1,0313 1,0315 1,0317 1,0320 1,0322 1,0325 1,0327 51

52 1,0435 1,0560 1,0564 1,0569 1,0573 1,0578 1,0582 1,0587 1,0592 1,0596 1,0601 1,0605 1,0610 52

53 1,0636 1,0821 1,0827 1,0834 1,0841 1,0847 1,0854 1,0861 1,0867 1,0874 1,0881 1,0888 1,0894 53

54 1,0836 1,1083 1,1092 1,1100 1,1109 1,1118 1,1127 1,1136 1,1145 1,1154 1,1163 1,1172 1,1181 54

55 1,1037 1,1346 1,1357 1,1368 1,1380 1,1391 1,1402 1,1413 1,1425 1,1436 1,1447 1,1459 1,1470 55

56 1,1238 1,1611 1,1624 1,1638 1,1651 1,1665 1,1679 1,1692 1,1706 1,1720 1,1733 1,1747 1,1761 56

57 1,1438 1,1877 1,1893 1,1909 1,1925 1,1941 1,1957 1,1973 1,1989 1,2005 1,2021 1,2037 1,2054 57

58 1,1639 1,2144 1,2163 1,2181 1,2200 1,2218 1,2237 1,2255 1,2274 1,2293 1,2311 1,2330 1,2349 58

59 1,1840 1,2413 1,2434 1,2455 1,2476 1,2497 1,2518 1,2539 1,2560 1,2582 1,2603 1,2624 1,2646 59

60 1,2040 1,2683 1,2706 1,2730 1,2754 1,2777 1,2801 1,2825 1,2849 1,2873 1,2896 1,2920 1,2944 60

61 1,2241 1,2954 1,2980 1,3006 1,3033 1,3059 1,3086 1,3112 1,3139 1,3165 1,3192 1,3219 1,3245 61

62 1,2442 1,3226 1,3255 1,3284 1,3313 1,3342 1,3372 1,3401 1,3430 1,3460 1,3489 1,3518 1,3548 62

63 1,2642 1,3500 1,3532 1,3564 1,3595 1,3627 1,3659 1,3691 1,3723 1,3756 1,3788 1,3820 1,3853 63

64 1,2843 1,3775 1,3809 1,3844 1,3879 1,3913 1,3948 1,3983 1,4018 1,4053 1,4089 1,4124 1,4159 64

65 1,3044 1,4051 1,4088 1,4126 1,4163 1,4201 1,4239 1,4277 1,4315 1,4353 1,4391 1,4429 1,4468 65

66 1,3244 1,4328 1,4369 1,4409 1,4450 1,4490 1,4531 1,4572 1,4613 1,4654 1,4695 1,4737 1,4778 66

67 1,3445 1,4607 1,4650 1,4694 1,4737 1,4781 1,4825 1,4869 1,4913 1,4957 1,5001 1,5046 1,5090 67

68 1,3646 1,4886 1,4933 1,4979 1,5026 1,5073 1,5120 1,5167 1,5214 1,5261 1,5309 1,5356 1,5404 68

69 1,3846 1,5167 1,5217 1,5266 1,5316 1,5366 1,5416 1,5466 1,5517 1,5567 1,5618 1,5669 1,5720 69

Page 51: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

100 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Furt

her

info

r-m

atio

n

Planning, assembly and installation information, heat output correction factors

Ascotherm® ecoFurther information

Correction factors CK (logarithmic calculation)

∆T [K]Exponent n

∆T [K]1,40 1,41 1,42 1,43 1,44 1,45 1,47 1,48 1,49 1,65 1,70 1,72 1,93

10 0,1056 0,1039 0,1022 0,1006 0,0990 0,0974 0,0943 0,0928 0,0913 0,0706 0,0652 0,0631 0,0451 10

11 0,1206 0,1188 0,1170 0,1153 0,1135 0,1118 0,1085 0,1069 0,1053 0,0827 0,0767 0,0744 0,0542 11

12 0,1362 0,1343 0,1324 0,1306 0,1287 0,1269 0,1233 0,1216 0,1199 0,0954 0,0889 0,0864 0,0641 12

13 0,1524 0,1504 0,1484 0,1464 0,1444 0,1425 0,1387 0,1369 0,1350 0,1089 0,1018 0,0991 0,0748 13

14 0,1691 0,1669 0,1648 0,1627 0,1607 0,1587 0,1547 0,1527 0,1508 0,1231 0,1155 0,1126 0,0863 14

15 0,1862 0,1840 0,1818 0,1796 0,1775 0,1754 0,1712 0,1692 0,1671 0,1379 0,1299 0,1268 0,0985 15

16 0,2038 0,2015 0,1992 0,1970 0,1948 0,1926 0,1882 0,1861 0,1840 0,1534 0,1450 0,1417 0,1116 16

17 0,2219 0,2195 0,2172 0,2148 0,2125 0,2103 0,2058 0,2036 0,2014 0,1696 0,1607 0,1573 0,1255 17

18 0,2404 0,2379 0,2355 0,2331 0,2308 0,2284 0,2238 0,2216 0,2193 0,1863 0,1771 0,1735 0,1401 18

19 0,2593 0,2568 0,2543 0,2519 0,2494 0,2471 0,2423 0,2400 0,2377 0,2037 0,1941 0,1904 0,1555 19

20 0,2786 0,2760 0,2735 0,2710 0,2686 0,2661 0,2613 0,2589 0,2566 0,2217 0,2118 0,2080 0,1717 20

21 0,2983 0,2957 0,2931 0,2906 0,2881 0,2856 0,2807 0,2783 0,2759 0,2403 0,2301 0,2262 0,1887 21

22 0,3183 0,3157 0,3132 0,3106 0,3081 0,3056 0,3006 0,2982 0,2957 0,2595 0,2491 0,2450 0,2064 22

23 0,3388 0,3362 0,3336 0,3310 0,3284 0,3259 0,3209 0,3184 0,3160 0,2792 0,2686 0,2645 0,2249 23

24 0,3596 0,3569 0,3543 0,3518 0,3492 0,3467 0,3416 0,3391 0,3367 0,2995 0,2888 0,2846 0,2441 24

25 0,3807 0,3781 0,3755 0,3729 0,3703 0,3678 0,3628 0,3603 0,3578 0,3204 0,3095 0,3053 0,2641 25

26 0,4022 0,3996 0,3970 0,3944 0,3919 0,3893 0,3843 0,3818 0,3793 0,3418 0,3309 0,3266 0,2849 26

27 0,4240 0,4214 0,4189 0,4163 0,4138 0,4112 0,4062 0,4037 0,4013 0,3638 0,3528 0,3485 0,3064 27

28 0,4462 0,4436 0,4411 0,4385 0,4360 0,4335 0,4285 0,4261 0,4236 0,3863 0,3753 0,3710 0,3287 28

29 0,4686 0,4661 0,4636 0,4611 0,4586 0,4561 0,4512 0,4488 0,4463 0,4093 0,3984 0,3941 0,3517 29

30 0,4914 0,4889 0,4865 0,4840 0,4815 0,4791 0,4743 0,4719 0,4695 0,4329 0,4220 0,4178 0,3755 30

31 0,5145 0,5121 0,5096 0,5072 0,5048 0,5024 0,4977 0,4953 0,4930 0,4569 0,4462 0,4420 0,4001 31

32 0,5379 0,5355 0,5331 0,5308 0,5284 0,5261 0,5215 0,5192 0,5169 0,4815 0,4710 0,4668 0,4253 32

33 0,5616 0,5593 0,5570 0,5547 0,5524 0,5501 0,5456 0,5433 0,5411 0,5066 0,4962 0,4922 0,4514 33

34 0,5855 0,5833 0,5811 0,5789 0,5766 0,5744 0,5701 0,5679 0,5657 0,5322 0,5221 0,5181 0,4781 34

35 0,6098 0,6076 0,6055 0,6034 0,6012 0,5991 0,5949 0,5928 0,5907 0,5582 0,5485 0,5446 0,5056 35

36 0,6343 0,6323 0,6302 0,6282 0,6261 0,6241 0,6200 0,6180 0,6160 0,5848 0,5754 0,5716 0,5339 36

37 0,6591 0,6572 0,6552 0,6533 0,6513 0,6494 0,6455 0,6436 0,6417 0,6118 0,6028 0,5992 0,5629 37

38 0,6842 0,6823 0,6805 0,6786 0,6768 0,6750 0,6713 0,6695 0,6677 0,6394 0,6307 0,6273 0,5926 38

39 0,7095 0,7078 0,7061 0,7043 0,7026 0,7009 0,6975 0,6957 0,6940 0,6674 0,6592 0,6560 0,6231 39

40 0,7351 0,7335 0,7319 0,7303 0,7287 0,7271 0,7239 0,7223 0,7207 0,6958 0,6882 0,6852 0,6543 40

41 0,7610 0,7595 0,7580 0,7565 0,7551 0,7536 0,7507 0,7492 0,7477 0,7248 0,7177 0,7149 0,6862 41

42 0,7871 0,7857 0,7844 0,7831 0,7817 0,7804 0,7777 0,7764 0,7751 0,7542 0,7477 0,7452 0,7189 42

43 0,8135 0,8123 0,8111 0,8099 0,8087 0,8075 0,8051 0,8039 0,8027 0,7840 0,7782 0,7760 0,7523 43

44 0,8401 0,8390 0,8380 0,8369 0,8359 0,8348 0,8328 0,8317 0,8307 0,8143 0,8093 0,8073 0,7864 44

45 0,8669 0,8660 0,8651 0,8643 0,8634 0,8625 0,8607 0,8599 0,8590 0,8451 0,8408 0,8391 0,8213 45

46 0,8940 0,8933 0,8926 0,8919 0,8911 0,8904 0,8890 0,8883 0,8876 0,8763 0,8728 0,8714 0,8569 46

47 0,9213 0,9208 0,9203 0,9197 0,9192 0,9186 0,9176 0,9170 0,9165 0,9079 0,9053 0,9042 0,8932 47

48 0,9489 0,9485 0,9482 0,9478 0,9475 0,9471 0,9464 0,9460 0,9457 0,9400 0,9383 0,9376 0,9302 48

49 0,9767 0,9765 0,9764 0,9762 0,9760 0,9759 0,9755 0,9754 0,9752 0,9726 0,9718 0,9714 0,9680 49

50 1,0047 1,0047 1,0048 1,0048 1,0048 1,0049 1,0049 1,0050 1,0050 1,0055 1,0057 1,0058 1,0065 50

51 1,0329 1,0332 1,0334 1,0337 1,0339 1,0341 1,0346 1,0349 1,0351 1,0389 1,0401 1,0406 1,0457 51

52 1,0614 1,0619 1,0623 1,0628 1,0632 1,0637 1,0646 1,0650 1,0655 1,0728 1,0750 1,0760 1,0856 52

53 1,0901 1,0908 1,0914 1,0921 1,0928 1,0935 1,0948 1,0955 1,0962 1,1070 1,1104 1,1118 1,1263 53

54 1,1190 1,1199 1,1208 1,1217 1,1226 1,1235 1,1253 1,1262 1,1271 1,1417 1,1463 1,1481 1,1677 54

55 1,1481 1,1492 1,1504 1,1515 1,1527 1,1538 1,1561 1,1572 1,1584 1,1768 1,1826 1,1849 1,2097 55

56 1,1774 1,1788 1,1802 1,1816 1,1830 1,1843 1,1871 1,1885 1,1899 1,2123 1,2194 1,2222 1,2526 56

57 1,2070 1,2086 1,2102 1,2119 1,2135 1,2151 1,2184 1,2200 1,2217 1,2482 1,2566 1,2600 1,2961 57

58 1,2367 1,2386 1,2405 1,2424 1,2443 1,2462 1,2499 1,2518 1,2537 1,2846 1,2943 1,2983 1,3403 58

59 1,2667 1,2688 1,2710 1,2731 1,2753 1,2774 1,2818 1,2839 1,2861 1,3213 1,3325 1,3370 1,3853 59

60 1,2968 1,2993 1,3017 1,3041 1,3065 1,3089 1,3138 1,3163 1,3187 1,3585 1,3711 1,3762 1,4310 60

61 1,3272 1,3299 1,3326 1,3353 1,3380 1,3407 1,3461 1,3489 1,3516 1,3960 1,4102 1,4159 1,4773 61

62 1,3578 1,3607 1,3637 1,3667 1,3697 1,3727 1,3787 1,3817 1,3847 1,4340 1,4497 1,4561 1,5244 62

63 1,3885 1,3918 1,3951 1,3983 1,4016 1,4049 1,4115 1,4148 1,4181 1,4723 1,4897 1,4967 1,5722 63

64 1,4195 1,4230 1,4266 1,4302 1,4338 1,4374 1,4446 1,4482 1,4518 1,5111 1,5301 1,5378 1,6208 64

65 1,4506 1,4545 1,4584 1,4622 1,4661 1,4700 1,4779 1,4818 1,4857 1,5503 1,5710 1,5794 1,6700 65

66 1,4820 1,4861 1,4903 1,4945 1,4987 1,5029 1,5114 1,5157 1,5199 1,5898 1,6123 1,6214 1,7199 66

67 1,5135 1,5180 1,5225 1,5270 1,5315 1,5361 1,5452 1,5498 1,5544 1,6298 1,6541 1,6639 1,7706 67

68 1,5452 1,5500 1,5549 1,5597 1,5646 1,5694 1,5792 1,5841 1,5891 1,6701 1,6962 1,7068 1,8219 68

69 1,5771 1,5823 1,5874 1,5926 1,5978 1,6030 1,6135 1,6187 1,6240 1,7108 1,7389 1,7502 1,8740 69

Page 52: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 101

Furt

her

info

rmat

ion

Planning, assembly and installation information, cooling capacity correction factors

Ascotherm® eco Further information

Correction factors CK (logarithmic calculation)

∆T [K]Exponent n

∆T [K]0,68 0,72 0,74 0,76 0,78 0,79 0,83 0,90 0,91 0,92 0,93

8 0,8610 0,8534 0,8497 0,8459 0,8422 0,8404 0,8330 0,8203 0,8185 0,8167 0,8149 8

9 0,9328 0,9290 0,9271 0,9252 0,9233 0,9223 0,9186 0,9120 0,9111 0,9101 0,9092 9

10 1,0020 1,0022 1,0022 1,0023 1,0023 1,0024 1,0025 1,0027 1,0027 1,0028 1,0028 10

11 1,0691 1,0734 1,0755 1,0776 1,0797 1,0808 1,0850 1,0925 1,0936 1,0947 1,0957 11

12 1,1343 1,1427 1,1470 1,1512 1,1555 1,1577 1,1663 1,1815 1,1837 1,1859 1,1881 12

13 1,1978 1,2105 1,2170 1,2235 1,2300 1,2332 1,2464 1,2698 1,2731 1,2765 1,2799 13

14 1,2597 1,2769 1,2856 1,2943 1,3032 1,3076 1,3255 1,3573 1,3620 1,3666 1,3712 14

15 1,3202 1,3419 1,3529 1,3640 1,3752 1,3808 1,4036 1,4443 1,4502 1,4561 1,4621 15

16 1,3794 1,4057 1,4191 1,4326 1,4462 1,4531 1,4808 1,5307 1,5379 1,5452 1,5525 16

17 1,4374 1,4685 1,4842 1,5001 1,5162 1,5244 1,5572 1,6165 1,6252 1,6339 1,6426 17

18 1,4944 1,5302 1,5483 1,5667 1,5854 1,5948 1,6329 1,7018 1,7119 1,7221 1,7323 18

19 1,5504 1,5909 1,6115 1,6325 1,6537 1,6644 1,7078 1,7867 1,7983 1,8099 1,8216 19

20 1,6054 1,6507 1,6739 1,6974 1,7212 1,7332 1,7821 1,8711 1,8842 1,8974 1,9106 20

21 1,6596 1,7098 1,7354 1,7615 1,7879 1,8013 1,8558 1,9551 1,9697 1,9845 1,9993 21

22 1,7129 1,7680 1,7962 1,8249 1,8540 1,8687 1,9288 2,0387 2,0549 2,0712 2,0877 22

23 1,7655 1,8255 1,8563 1,8876 1,9194 1,9355 2,0013 2,1219 2,1397 2,1577 2,1758 23

24 1,8173 1,8823 1,9157 1,9496 1,9842 2,0017 2,0733 2,2048 2,2242 2,2439 2,2637 24

25 1,8685 1,9385 1,9744 2,0111 2,0484 2,0673 2,1447 2,2873 2,3084 2,3297 2,3512 25

26 1,9190 1,9940 2,0326 2,0719 2,1120 2,1324 2,2157 2,3695 2,3923 2,4153 2,4386 26

27 1,9689 2,0489 2,0901 2,1322 2,1751 2,1969 2,2862 2,4513 2,4759 2,5007 2,5257 27

∆T [K]Exponent n

∆T [K]0,94 0,95 0,97 1,00 1,02 1,04 1,05 1,06 1,10 1,12 1,19

8 0,8131 0,8113 0,8077 0,8024 0,7989 0,7954 0,7936 0,7919 0,7849 0,7815 0,7695 8

9 0,9083 0,9073 0,9055 0,9027 0,9009 0,8990 0,8981 0,8972 0,8935 0,8917 0,8853 9

10 1,0028 1,0029 1,0029 1,0030 1,0031 1,0031 1,0032 1,0032 1,0033 1,0034 1,0036 10

11 1,0968 1,0979 1,1001 1,1033 1,1055 1,1077 1,1087 1,1098 1,1142 1,1164 1,1241 11

12 1,1903 1,1925 1,1969 1,2036 1,2081 1,2126 1,2148 1,2171 1,2261 1,2307 1,2467 12

13 1,2833 1,2867 1,2936 1,3039 1,3109 1,3178 1,3213 1,3248 1,3390 1,3461 1,3713 13

14 1,3759 1,3806 1,3900 1,4042 1,4138 1,4234 1,4283 1,4331 1,4527 1,4626 1,4978 14

15 1,4681 1,4741 1,4862 1,5045 1,5169 1,5293 1,5356 1,5418 1,5672 1,5801 1,6259 15

16 1,5599 1,5673 1,5822 1,6048 1,6201 1,6355 1,6432 1,6510 1,6825 1,6985 1,7557 16

17 1,6514 1,6602 1,6780 1,7051 1,7234 1,7419 1,7512 1,7606 1,7986 1,8179 1,8871 17

18 1,7425 1,7529 1,7737 1,8054 1,8269 1,8486 1,8595 1,8706 1,9153 1,9381 2,0199 18

19 1,8334 1,8453 1,8692 1,9057 1,9305 1,9555 1,9682 1,9809 2,0327 2,0590 2,1541 19

20 1,9240 1,9374 1,9646 2,0060 2,0341 2,0627 2,0771 2,0916 2,1506 2,1808 2,2897 20

21 2,0142 2,0293 2,0598 2,1063 2,1379 2,1700 2,1863 2,2026 2,2692 2,3033 2,4266 21

22 2,1043 2,1210 2,1548 2,2066 2,2418 2,2776 2,2957 2,3139 2,3884 2,4265 2,5647 22

23 2,1941 2,2125 2,2498 2,3069 2,3458 2,3854 2,4054 2,4256 2,5080 2,5503 2,7040 23

24 2,2836 2,3038 2,3446 2,4072 2,4499 2,4933 2,5153 2,5375 2,6283 2,6748 2,8445 24

25 2,3730 2,3949 2,4393 2,5075 2,5541 2,6014 2,6255 2,6497 2,7490 2,8000 2,9861 25

26 2,4621 2,4858 2,5339 2,6078 2,6583 2,7098 2,7358 2,7622 2,8702 2,9257 3,1288 26

27 2,5510 2,5765 2,6284 2,7081 2,7626 2,8182 2,8464 2,8749 2,9918 3,0520 3,2725 27

Page 53: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® ecoFurther information

102 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Furt

her

info

r-m

atio

n

Planning, assembly and installation instructions

Scope of delivery• External, adjustable and acoustically decoupled height adjust-

ments (pre-installed)

• For KRP91, KRN92 and KRN81 aluminium linear grille (on

request, delivery can be postponed until the end of the

construction phase)

• For KC281 and KC481 aluminium roll-up grille (on request,

delivery can be postponed until the end of the construction

phase)

• Plastic elements for acoustic decoupling

• Installation cover and edge bar protection (for protection

during the construction phase)

Planning advices• To compensate for cold air that occurs on large window areas,

the trench convectors must be dimensioned to extend along

the entire length of the window.

• The thermal behaviour of screeds and floors can compress the

floor pans of trench convectors. To prevent this, expansion

joints must be provided.

• When electrical cables or a thermostatic sensor head with a

remote sensor will be used, it is necessary to install an empty

conduit.

• The installation cover supplied serves to protect the convec-

tor during the construction phase and should be replaced

with the supplied linear grille or roll-up grille only after all

construction work has been completed. The installation cover

has only limited loading capability and is not suitable for use

as a surface to support scaffolds, ladders etc.

• The convector must be accessible for maintenance work at

any time.

Installation instructions

Positioning and arrangement

• Remove the packaging film and packaging cardboard from

the trench convector before installation. If the top grille

has already been delivered, store it in a safe location until

construction work has been completed.

• Place the trench convector in position and use the external

height adjustments to align it. The height adjustments can be

placed in the correct position with the aid of a screwdriver.

• Use the mounting brackets to secure the floor pan to the

floor.

• If necessary, use insulation underneath and on the sides of the

floor pan as well.

• Note the acoustic decoupling

Connecting of the trench convector

• Water connection to the face (as standard) or room sided with

openings already provided for pipe entry (on request, other

connection arrangements also possible).

• Attach fittings and connect convector to pipework.

• To prevent entry of screed into the floor pan, seal the provi-

ded openings with suitable material. (e. g. plastic plugs from

the accessory range)

• Perform a pressure test.

• Cover the convector with the supplied installation cover for

protection

• When components from other manufacturers are used (e.g.

connection set, actuator,…) that are not in the accessory

range for the Ascotherm eco, pay attention to the installation

dimensions.

Intended use

The Ascotherm KRN81, KC281 and KC481 are intended exclusi-

vely for use in indoor areas (e.g. conservatories, residential and

commercial areas, showrooms, etc. The Ascotherm KRN81, KC281

and KC481 cannot be used in swimming pools, damp locations

and outdoor areas. In case of doubt, always consult the manufac-

turer. Any other or additional use shall be considered as impro-

per use.

Safety instructions

• Electrical work may be carried out only by authorised electri-

cians. Connection must comply with valid VDE regulations and

the EVU directives.

• When installing Ascotherm KRN81, KC281 and KC481, a suita-

ble residual current-operated protective device (RCD) / earth

leakage circuit breaker (less than or equal to 30 mA) must be

installed.

• In case of failure to comply with the regulations and directives

malfunctions with consequential damage and endangerment

of individuals can occur. Mixing up wires or connecting impro-

perly can result in MORTAL DANGER!

• Note additional safety information in the installation instruc-

tions.

Page 54: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KRP91Further information

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 103

Ordering process

Furt

her

info

rmat

ion

Product Flow/return Floor pan Grille

Po

s

Ro

om

Nu

mb

er

Pro

du

ct /

vers

ion

Heig

ht

in m

m

Dep

th i

n m

m

Len

gth

in

mm

Co

nn

ect

ion

syst

em

Co

up

lin

g o

f ra

dia

tor

po

siti

on

Desi

gn

(in

terc

on

nect

ed

)

Arr

an

gem

en

t

Co

nn

ect

ion

siz

e

Pre

ssu

re v

ers

ion

To

p g

rill

e

Fit

tin

gs

Act

uato

r

Fit

tin

g

Pan

co

lou

r

Pan

co

lou

r co

de

Ed

ge b

ar

colo

ur

To

p g

rill

e v

ers

ion

Sp

eci

als

|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |VG| |RG| |DRU| |ABD| |EBT| |STT| |VRS| |FAR1| |FNR1| |RDL| |AUS| |BES|

1 WG 1 KRP91 150 185 1000 2 BB 64 64 10 LR RAL 7016 ELO ELO

2 WG 1 KRP91 92 260 2050 2 33 64 64 10 RR TS1 STT VRS RAL 7016 DKS DKS SBL

RoomInformation on the room in which the radiator will be installed

Ordering information Ordering code

Conservatory WG

Entrance Entrance

Administrative building VG

... ...

NumberNumber of radiators

Ordering informationOrdering code

for example

1 radiator 1

2 radiators 2

Product / version

Ordering information Ordering code

Ascotherm KRP91 Natural Convection KRP91

|HOE| - Height BH in mm

Ordering information Ordering code

92 mm 92

120 mm 120

150 mm 150

200 mm 200

|MT| - Depth in mm

Ordering information Ordering code

185 mm 185

210 mm 210

260 mm 260

310 mm 310

360 mm 360

400 mm 400

|LAE| - Length in mm

Ordering information Ordering code

from 1000 mm to 5000 mm 1000 - 5000

|VT| - Flow / return: Connection system

Ordering information Ordering code

2-pipe system (flow and return

are separate)2

Other connection arrangements

Ordering information Ordering code

Coupled on same side in series 75

Special connections 99

|KHP| - Coupling of radiator position

Ordering information Ordering code

Without coupling –

Initial radiator 1

Centred radiator 2

Final radiator 3

|BF| - radiator design

Ordering information Ordering code

Without –

Connected at right end 1

Connected at both ends 2

Connected at left end 3

|ANB| - Flow / return: Arrangement

Ordering information Ordering code

1st digit: pos. flow

2nd digit: pos. return

DB

8 361

|VG| - Flow connection size

Ordering information Ordering code

G 3/4’’ 64

|RG| - Return connection size

Ordering information Ordering code

G 3/4’’ 64

|DRU| - Pressure version in bar (Pa)

Ordering information Ordering code

Standard version: 10 bar (1000 kPa) 10

High-pressure version: 16 bar (1600 kPa) 16

Page 55: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KRP91Further information

104 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Ordering process

Furt

her

info

r-m

atio

n

|ABD| - Top grille

Ordering information Ordering code

Without –

Standard version: Aluminium linear grille LR

Aluminium roll-up grille RR

|EBT| - Fittings

Ordering information Ordering code

Without impact sound insulation –

With impact sound insulation TS1

|STT| - Actuator

Ordering information Ordering code

Without actuator –

With actuator STT

|VRS| - Fitting

Ordering information Ordering code

Without Fitting –

With Fitting VRS

Floor pan |FAR1| - Surface: Colour

Ordering information Ordering code

RAL RAL

|FNR1| - Surface: Colour code

Ordering information Ordering code

Anthracite grey 7016

Edge bar |RDL| - Edge bar colour

Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Stainless steel EDS

Pan colour FAR1

Grille colour FAR2

Top grilles |AUS| - Top grille version Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Finished LAC

Stainless steel 1) EDS

Type of wood: beech 1) HBU

Type of wood: oak 1) HEI

Type of wood: ash 1) HES

1) This version is only possible with roll-up grille.

|BES| - Specials

Ordering information Ordering code

Mitre / column 75

Single mitre 76

Double mitre 77

Special height SBH

Special length SBL

Special depth SBT

= Standard version, instead of value, it is also

possible to insert "-"

Page 56: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KRN92Further information

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 105

Ordering process

Furt

her

info

rmat

ion

Product Flow/return Floor pan Grile

Po

s

Ro

om

Nu

mb

er

Pro

du

ct /

vers

ion

Heig

ht

in m

m

Dep

th i

n m

m

Len

gth

in

mm

Co

nn

ect

ion

syst

em

Co

up

lin

g o

f ra

dia

tor

po

siti

on

Desi

gn

(in

terc

on

nect

ed

)

Arr

an

gem

en

t

Nu

mb

er

of

air

co

nn

ec-

tio

ns

Air

co

nn

ect

ion

arr

an

-g

em

en

t

Air

co

nn

ect

ion

siz

e

Co

nn

ect

ion

siz

e

Pre

ssu

re v

ers

ion

To

p g

rill

e

Fit

tin

gs

Act

uato

r

Fit

tin

g

Pan

co

lou

r

Pan

co

lou

r co

de

Ed

ge b

ar

colo

ur

To

p g

rill

e v

ers

ion

Sp

eci

als

|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |LAZ| |LAP| |LAG| |VG| |RG| |DRU| |ABD| |EBT| |STT| |VRS| |FAR1| |FNR1| |RDL| |AUS| |BES|

1 HK2 2 KRN92 110 310 2750 2 11 1 F 63 64 64 10 LR RAL 7016 ELO ELO

2 HK2 1 KRN92 200 185 2000 2 BB 1 F 100 64 64 10 RR STT VRS RAL 7016 SWZ SWZ

RoomInformation on the room in which the radiator will be installed

Ordering information Ordering code

Conservatory WG

Administrative building VG

... ...

NumberNumber of radiators

Ordering information Ordering code

1 radiator 1

2 radiators 2

Product / version

Ordering information Ordering code

Ascotherm KRN92 Natural convection with

additional air connectionKRN92

|HOE| - Height BH in mm

Ordering information Ordering code

110 mm 110

150 mm 150

200 mm 200

|MT| - Depth in mm

Ordering information Ordering code

185 mm 185

210 mm 210

260 mm 260

310 mm 310

360 mm 360

400 mm 400

|LAE| - Length in mm

Ordering information Ordering code

from 1000 mm to 5000 mm 1000 - 5000

|VT| - Flow / return: Connection system

Ordering information Ordering code

2-pipe system (flow and return

are separate)2

Other connection arrangements

Ordering information Ordering code

Coupled on same side in series 75

Special connections 99

|KHP| - Coupling of radiator position

Ordering information Ordering code

Without coupling –

Initial radiator 1

Centred radiator 2

Final radiator 3

|BF| - radiator design

Ordering information Ordering code

Without –

Connected at right end 1

Connected at both ends 2

Connected at left end 3

|ANB| - Flow / return: Arrangement

Ordering information Ordering code

1st digit: pos. flow

2nd digit: pos. return

DB

8 361

|LAZ| - Number of air connections

Ordering information Ordering code

One 1

Select 2 - 10 2 - 10

|LAP| - Air connection arrangement

Ordering information Ordering code

Air connection F

Special connection according to drawing SON

Page 57: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KRN92Further information

106 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Ordering process

Furt

her

info

r-m

atio

n

|LAG| - Air connection size

Ordering information Ordering code

Connection 63 mm 63

Connection 80 mm 80

Connection 100 mm 100

Connection 125 mm 125

• Connection size depends on height

|VG| - Flow connection size

Ordering information Ordering code

G 3/4’’ 64

|RG| - Return connection size

Ordering information Ordering code

G 3/4’’ 64

|DRU| - Pressure version in bar (Pa)

Ordering information Ordering code

Standard version: 10 bar (1000 kPa) 10

High-pressure version: 16 bar (1600 kPa) 16

|ABD| - Top grille

Ordering information Ordering code

Without –

Standard version: Aluminium linear grille LR

Aluminium roll-up grille RR

|EBT| - Fittings

Ordering information Ordering code

Without impact sound insulation –

With impact sound insulation TS1

|STT| - Actuator

Ordering information Ordering code

Without actuator –

With actuator STT

|VRS| - Fitting

Ordering information Ordering code

Without Fitting –

With Fitting VRS

Floor pan |FAR1| - Surface: Colour

Ordering information Ordering code

RAL RAL

|FNR1| - Surface: Colour code

Ordering information Ordering code

Anthracite grey 7016

Edge bar |RDL| - Edge bar colour

Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Stainless steel EDS

Pan colour FAR1

Grille colour FAR2

Top grilles |AUS| - Top grille version Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Finished LAC

Stainless steel 1) EDS

Type of wood: beech 1) HBU

Type of wood: oak 1) HEI

Type of wood: ash 1) HES

1) This version is only possible with roll-up grille.

|BES| - Specials

Ordering information Ordering code

Mitre / column 75

Single mitre 76

Double mitre 77

Special height SBH

Special length SBL

Special depth SBT

= Standard version, instead of value, it is also

possible to insert "-"

Page 58: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KRN81Further information

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 107

Ordering process

Furt

her

info

rmat

ion

Product Flow/return Floor pan Grille

Po

s

Ro

om

Nu

mb

er

Pro

du

ct /

vers

ion

Heig

ht

in m

m

Dep

th i

n m

m

Len

gth

in

mm

Co

nn

ect

ion

syst

em

Co

up

lin

g o

f ra

dia

tor

po

siti

on

Desi

gn

(in

terc

on

nect

ed

)

Arr

an

gem

en

t

Co

nn

ect

ion

siz

e

Pre

ssu

re v

ers

ion

To

p g

rill

e

Fit

tin

gs

Fil

ter

fleece

Act

uato

r

Fit

tin

g

Co

ntr

ol

syst

em

Bu

ild

ing

man

ag

em

en

t sy

stem

Pan

co

lou

r

Pan

co

lou

r co

de

To

p g

rill

e v

ers

ion

Ed

ge b

ar

colo

ur

Sp

eci

als

|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |VG| |RG| |DRU| |ABD| |EBT| |FVL| |STT| |VRS| |RLT| |GLT| |FAR1| |FNR1| |AUS| |RDL| |BES|

1 R01 1 KRN81 110 310 1250 2 BB 64 64 10 RR TS1 FV RLT RAL 7016 HEI ELO

2 R01 1 KRN81 110 260 3000 2 33 64 64 10 LR STT VRS RLT RAL 7016 ELO ELO

RoomInformation on the room in which the radiator will be installed

Ordering information Ordering code

Conservatory WG

Administrative building VG

... ...

NumberNumber of radiators

Ordering information Ordering code

1 radiator 1

2 radiators 2

Product / version

Ordering information Ordering code

Ascotherm KRN81 Forced convection with

cross-flow fanKRN81

|HOE| - Height BH in mm

Ordering information Ordering code

110 mm 110

|MT| - Depth in mm

Ordering information Ordering code

185 mm 185

210 mm 210

260 mm 260

310 mm 310

360 mm 360

|LAE| - Length in mm

Ordering information Ordering code

from 1250 mm to 4000 mm 1250 - 4000

|VT| - Flow / return: Connection system

Ordering information Ordering code

2-pipe system (flow and return

are separate)2

Other connection arrangements

Ordering information Ordering code

Coupled on same side in series 75

Special connections 99

|KHP| - Coupling of radiator position

Ordering information Ordering code

Without coupling –

Initial radiator 1

Centred radiator 2

Final radiator 3

|BF| - radiator design

Ordering information Ordering code

Without –

Connected at right end 1

Connected at both ends 2

Connected at left end 3

|ANB| - Flow / return: Arrangement

Ordering information Ordering code

1st digit: pos. flow

2nd digit: pos. return

DB

8 361

|VG| - Flow connection size

Ordering information Ordering code

G 3/4’’ 64

|RG| - Return connection size

Ordering information Ordering code

G 3/4’’ 64

|DRU| - Pressure version in bar (Pa)

Ordering information Ordering code

Standard version: 10 bar (1000 kPa) 10

High-pressure version: 16 bar (1600 kPa) 16

Page 59: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KRN81Further information

108 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Ordering process

Furt

her

info

r-m

atio

n

|ABD| - Top grille

Ordering information Ordering code

Without –

Standard version: Aluminium linear grille LR

Aluminium roll-up grille RR

|EBT| - Fittings

Ordering information Ordering code

Without impact sound insulation –

With impact sound insulation TS1

|FVL| - Filter fleece

Ordering information Ordering code

Without filter fleece –

With filter fleece FV

|STT| - Actuator

Ordering information Ordering code

Without actuator –

With actuator STT

|VRS| - Fitting

Ordering information Ordering code

Without Fitting –

With Fitting VRS

|RLT| - Control system

Ordering information Ordering code

Without control system –

With control system RLT

|GLT| - Building management system

Ordering information Ordering code

Without –

KNX card KNX

LON card LON

Floor pan |FAR1| - Surface: Colour

Ordering information Ordering code

RAL RAL

|FNR1| - Surface: Colour code

Ordering information Ordering code

Anthracite grey 7016

Edge bar |RDL| - Edge bar colour

Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Stainless steel EDS

Pan colour FAR1

Grille colour FAR2

Top grilles |AUS| - Top grille version Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Finished LAC

Stainless steel 1) EDS

Type of wood: beech 1) HBU

Type of wood: oak 1) HEI

Type of wood: ash 1) HES

1) This version is only possible with roll-up grille.

|BES| - Specials

Ordering information Ordering code

Mitre / column 75

Single mitre 76

Double mitre 77

Special height SBH

Special length SBL

Special depth SBT

= Standard version, instead of value, it is also

possible to insert "-"

Page 60: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC281Further information

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 109

Ordering process

Furt

her

info

rmat

ion

Product Flow/return Floor pan Grille

Po

s

Ro

om

Nu

mb

er

Pro

du

ct /

vers

ion

Heig

ht

in m

m

Dep

th i

n m

m

Len

gth

in

mm

Co

nn

ect

ion

syst

em

Co

up

lin

g o

f ra

dia

tor

po

siti

on

Desi

gn

(in

terc

on

nect

ed

)

Heati

ng

/ c

oo

lin

g a

rran

-g

em

en

t

Co

nn

ect

ion

siz

e

Pre

ssu

re v

ers

ion

To

p g

rill

e

Fit

tin

gs

Fil

ter

fleece

Co

nd

en

sate

pu

mp

Act

uato

r

Fit

tin

g

Co

ntr

ol

syst

em

Bu

ild

ing

man

ag

em

en

t sy

stem

Pan

co

lou

r

Pan

co

lou

r co

de

Ed

ge b

ar

colo

ur

To

p g

rill

e v

ers

ion

Sp

eci

als

|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |VG| |RG| |DRU| |ABD| |EBT| |FVL| |PUM| |STT| |VRS| |RLT| |GLT| |FAR1| |FNR1| |RDL| |AUS| |BES|

1 R02 2KC

281130 310 1250 2 BB 64 64 10 RR TS1 RAL 7016 ELO ELO

RoomInformation on the room in which the radiator will be installed

Ordering information Ordering code

Conservatory WG

Entrance Entrance

Administrative building VG

... ...

NumberNumber of radiators

Ordering information Ordering code

1 radiator 1

2 radiators 2

Product / version

Ordering information Ordering code

Ascotherm KC281 heating and cooling in

2-pipe systemKC 281

|HOE| - Height BH in mm

Ordering information Ordering code

130 mm 130

155 mm 155

|MT| - Depth in mm

Ordering information Ordering code

310 mm 310

360 mm 360

|LAE| - Length in mm

Ordering information Ordering code

1250 mm 1250

2000 mm 2000

2750 mm 2750

|VT| - Flow / return: Connection system

Ordering information Ordering code

2-pipe system (flow and return

are separate)2

Other connection arrangements

Ordering information Ordering code

Coupled on same side in series 75

Special connections 99

|KHP| - Coupling of radiator position

Ordering information Ordering code

Without coupling –

Initial radiator 1

Centred radiator 2

Final radiator 3

|BF| - radiator design

Ordering information Ordering code

Without –

Connected at right end 1

Connected at both ends 2

Connected at left end 3

|ANB| - Flow / return: Arrangement

Ordering information Ordering code

1st digit: pos. flow

2nd digit: pos. return

DB

8 361

|VG| - Flow connection size

Ordering information Ordering code

G 3/4’’ 64

|RG| - Return connection size

Ordering information Ordering code

G 3/4’’ 64

|DRU| - Pressure version in bar (Pa)

Ordering information Ordering code

Standard version: 10 bar (1000 kPa) 10

High-pressure version: 16 bar (1600 kPa) 16

Page 61: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC281Further information

110 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Ordering process

Furt

her

info

r-m

atio

n

|ABD| - Top grille

Ordering information Ordering code

Without –

Aluminium linear grille LR

Standard version: Aluminium roll-up grille RR

|EBT| - Fittings

Ordering information Ordering code

Without impact sound insulation –

With impact sound insulation TS1

|FVL| - Filter fleece

Ordering information Ordering code

Without filter fleece –

With filter fleece FV

|PUM| - Condensate pump

Ordering information Ordering code

Without condensate pump –

With condensate pump PUM

|STT| - Actuator

Ordering information Ordering code

Without actuator –

With actuator STT

|VRS| - Fitting

Ordering information Ordering code

Without Fitting –

With Fitting VRS

|RLT| - Control system

Ordering information Ordering code

Without control system –

With control system RLT

|GLT| - Building management system

Ordering information Ordering code

Without –

KNX card KNX

LON card LON

Floor pan |FAR1| - Surface: Colour

Ordering information Ordering code

RAL RAL

|FNR1| - Surface: Colour code

Ordering information Ordering code

Anthracite grey 7016

Edge bar |RDL| - Edge bar colour

Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Stainless steel EDS

Pan colour FAR1

Grille colour FAR2

Top grilles |AUS| - Top grille version Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Finished LAC

Stainless steel 1) EDS

Type of wood: beech 1) HBU

Type of wood: oak 1) HEI

Type of wood: ash 1) HES

1) This version is only possible with roll-up grille.

|BES| - Specials

Ordering information Ordering code

Mitre / column 75

Single mitre 76

Double mitre 77

Special height SBH

Special length SBL

Special depth SBT

= Standard version, instead of value, it is also

possible to insert "-"

Page 62: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Further information

Prices without value-added tax. Technical specifications subject to change.Prices and Technology 2015-N 111

Ordering process

Furt

her

info

rmat

ion

Product Flow/return Floor pan Grille

Po

s

Ro

om

Nu

mb

er

Pro

du

ct /

vers

ion

Heig

ht

in m

m

Dep

th i

n m

m

Len

gth

in

mm

Co

nn

ect

ion

syst

em

Co

up

lin

g o

f ra

dia

tor

po

siti

on

Desi

gn

(in

terc

on

nect

ed

)

Arr

an

gem

en

t h

eati

ng

Arr

an

gem

en

t co

oli

ng

Co

nn

ect

ion

siz

e h

eati

ng

Co

nn

ect

ion

siz

e c

oo

lin

g

Pre

ssu

re v

ers

ion

To

p g

rill

e

Fit

tin

gs

Fil

ter

fleece

Co

nd

en

sate

pu

mp

Act

uato

r

Fit

tin

g

Co

ntr

ol

syst

em

Bu

ild

ing

man

ag

em

en

t sy

stem

Pan

co

lou

r

Pan

co

lou

r co

de

Ed

ge b

ar

colo

ur

To

p g

rill

e v

ers

ion

Sp

eci

als

|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |ANK| |VG| |RG| |VGK| |RGK| |DRU| |ABD| |EBT| |FVL| |PUM| |STT| |VRS| |RLT| |GLT| |FAR1| |FNR1| |RDL| |AUS| |BES|

1 LW 2 KC 481 155 330 2750 4 11 33 64 64 64 64 10 RR TS1 FV STT VRS RLT RAL 7016 EDS EDS

RoomInformation on the room in which the radiator will be installed

Ordering information Ordering code

Conservatory WG

Entrance Entrance

Administrative building VG

... ...

NumberNumber of radiators

Ordering information Ordering code

1 radiator 1

2 radiators 2

Product / version

Ordering information Ordering code

Ascotherm KC481 heating and cooling in

4-conductor systemKC 481

|HOE| - Height BH in mm

Ordering information Ordering code

130 mm 130

155 mm 155

|MT| - Depth in mm

Ordering information Ordering code

330 mm 330

360 mm 360

|LAE| - Length in mm

Ordering information Ordering code

1250 mm 1250

2000 mm 2000

2750 mm 2750

|VT| - Flow / return: Connection system

Ordering information Ordering code

4-pipe system (heating flow and

return, cooling flow and return

are separate)

4

Other connection arrangements

Ordering information Ordering code

Coupled on same side in series 75

Special connections 99

|KHP| - Coupling of radiator position

Ordering information Ordering code

Without coupling –

Initial radiator 1

Centred radiator 2

Final radiator 3

|BF| - radiator design

Ordering information Ordering code

Without –

Connected at right end 1

Connected at both ends 2

Connected at left end 3

|ANB| - Flow / return: Heating arrangement

Ordering information Ordering code

1st digit: pos. flow

2nd digit: pos. return

DB

8 361

|ANK| - Flow / return: Cooling arrangement

Ordering information Ordering code

1st digit: pos. flow

2nd digit: pos. return

DB

8 361

|VG| - Flow connection size

Ordering information Ordering code

G 3/4’’ 64

|RG| - Return connection size

Ordering information Ordering code

G 3/4’’ 64

Page 63: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Ascotherm® eco KC481Further information

112 Prices and Technology 2015-N Prices without value-added tax. Technical specifications subject to change.

Ordering process

Furt

her

info

r-m

atio

n

|VGK| - Flow connection size

Ordering information Ordering code

G 3/4’’ 64

|RGK| - Return connection size

Ordering information Ordering code

G 3/4’’ 64

|DRU| - Pressure version in bar (Pa)

Ordering information Ordering code

Standard version: 10 bar (1000 kPa) 10

High-pressure version: 16 bar (1600 kPa) 16

|ABD| - Top grille

Ordering information Ordering code

Without –

Aluminium linear grille LR

Standard version: Aluminium roll-up grille RR

|EBT| - Fittings

Ordering information Ordering code

Without impact sound insulation –

With impact sound insulation TS1

|FVL| - Filter fleece

Ordering information Ordering code

Without filter fleece –

With filter fleece FV

|PUM| - Condensate pump

Ordering information Ordering code

Without condensate pump –

With condensate pump PUM

|STT| - Actuator

Ordering information Ordering code

Without actuator –

With actuator STT

|VRS| - Fitting

Ordering information Ordering code

Without Fitting –

With Fitting VRS

|RLT| - Control system

Ordering information Ordering code

Without control system –

With control system RLT

|GLT| - Building management system

Ordering information Ordering code

Without –

KNX card KNX

LON card LON

Floor pan |FAR1| - Surface: Colour

Ordering information Ordering code

RAL RAL

|FNR1| - Surface: Colour code

Ordering information Ordering code

Anthracite grey 7016

Edge bar |RDL| - Edge bar colour

Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Stainless steel EDS

Pan colour FAR1

Grille colour FAR2

Top grilles |AUS| - Top grille version Ordering information Ordering code

Anodised ELO

Bronze BRO

Brass MES

Dark silver DKS

black SWZ

Finished LAC

Stainless steel 1) EDS

Type of wood: beech 1) HBU

Type of wood: oak 1) HEI

Type of wood: ash 1) HES

1) This version is only possible with roll-up grille.

|BES| - Specials

Ordering information Ordering code

Mitre / column 75

Single mitre 76

Double mitre 77

Special height SBH

Special length SBL

Special depth SBT

= Standard version, instead of value, it is also

possible to insert "-"

Page 64: Ascotherm eco KC481 Heating and cooling in 4-conductor system · 2018-10-19 · Ascotherm® eco KC481 Heating and cooling in 4-conductor system 50 Prices and Technology 2015-N Prices

Prodcut Flow/return Floor pan Grille

Po

s

Ro

om

Nu

mb

er

Pro

du

ct / v

ers

ion

Heig

ht

in m

m

Dep

th in

mm

Len

gth

in

mm

Co

nn

ect

ion

syst

em

Co

up

lin

g o

f ra

dia

-to

r p

osi

tio

n

Desi

gn

(in

terc

on

-n

ect

ed

)

Arr

an

gem

en

t h

eati

ng

Arr

an

gem

en

t co

olin

g

Nu

mb

er

of

air

con

nect

ion

s

Air

co

nn

ect

ion

arr

an

gem

en

t

Air

co

nn

ect

ion

siz

e

Pre

ssu

re v

ers

ion

To

p g

rille

Fit

tin

gs

Filte

r fl

eece

Co

nd

en

sate

pu

mp

Act

uato

r

Fit

tin

g

Co

ntr

ol sy

stem

Bu

ild

ing

man

ag

e-

men

t sy

stem

Pan

co

lou

r

Pan

co

lou

r co

de

Ed

ge b

ar

colo

ur

To

p g

rille v

ers

ion

Sp

eci

als

|HOE| |MT| |LAE| |VT| |KHP| |BF| |ANB| |ANK| |LAZ| |LAP| |LAG| |DRU| |ABD| |EBT| |FVL| |PUM| |STT| |VRS| |RLT| |GLT| |FAR1| |FNR1| |RDL| |AUS| |BES|

1

2

3

4

5

6

7

8

9

10

Ascotherm® ecoOrder Form

Ordering process

Customer Ordered

by Object Desired delivery date

Address Address Address

Postcode

/ city

Postcode

/ city

Postcode

/ city

Tel. / Fax Tel. / Fax Tel. / Fax