nSwitching : Virtual Machine Aware Relay Hardware Switching to improve intra-NIC Virtual Machine Traffic. Author(s ): Bardgett , J. Harris Corp., Melbourne, FL, USA Zou , C. Published in: Communications (ICC), 2012 IEEE International Conference on Date of Conference: 10-15 June 2012. - PowerPoint PPT Presentation
Citation preview
National Tsing Hua University
Speaker : Wei-Fa Liao 101062544
nSwitching: Virtual Machine Aware Relay Hardware Switching to improve intra-NIC Virtual Machine Traffic
Author(s):Bardgett, J.
Harris Corp., Melbourne, FL, USA Zou, C.
Published in:Communications (ICC), 2012 IEEE International Conference on
Date of Conference: 10-15 June 2012
National Tsing Hua University
Outline
Introduction
Background
Proposed nSwitch design
Evaluation
Conclusion
2 /21
National Tsing Hua University
Introduction
Traditional data center network switching architecture involves: Definition of switching platforms Port bandwidth Physical medium connectivity Virtual local-area network (VLAN) Internet Protocol (IP) addressing Fail-over mechanisms Port bonding Quality of service (QoS) Security
In cloud computing ?With the introduction of improved switching protocols and virtualization,
increased utilization of hardware has imposed many design challenges.
3 /21
National Tsing Hua University
Introduction cont.
It is important to consider the frequent switching of frames between VMs on the same machine.
Some proposed solutions: vSwitch – a virtual switch was hypervisor integrated software for VM to VM switching
• increase CPU load • vm-vm traffic is not transparent.
IEEE 802.1Qbg(HP,IBM) and 802.1Qbh(Cisco) – its permits reflective relay (hairpin turn)• require modification of the NIC and reflective relay upgrade to the external network hardware to switch
VM-VM frames originating and terminating on the same physical Ethernet port
We propose the nSwitch architecture to improve the VM-VM switching performance for traffic in the same computer across multiple CPUs and sockets. nSwitching is compatible with the SR-IOV specification without any Ethernet frame
alteration.
4 /21
National Tsing Hua University
Background
Frame fromPort x
Forward to belonging
Port
Filter Forward to
all ports ( except port
x )
Y
YN
N
Address Learning
FrameForwarding
DMAC in FDB?
Belong to Port x ?
VM1 VM2
Hypervisor
hardware
pSwitch
Port
5 /21
National Tsing Hua University
vSwitch
The vSwitch makes monitoring of protocols or bandwidth usage complicated or impossible.
Open-vSwitch does have rate limiting but not QoS (e.g. 802.1p).
Concerns like limited I/O bandwidth and the additional skill development for server administrators makes managing the vSwitch complex.
In addition, vSwitch could cause very high CPU loads with software switching .
6 /21
National Tsing Hua University
IEEE 802.1Qbg
Virtual Ethernet port aggregator (VEPA) that aggregates virtual machine packets on the server before the resulting single stream is transmitted to the switch.
In VEPA all the frames from the VMs are forwarded out to the switch.
Reflective Relay is EnabledVM-VM traffic is TransparentRequire modification of the NIC/Switch
7 /21
National Tsing Hua University
IEEE 802.1Qbh
Basically the frames from each VM is tagged with an identifier, called a VN-Tag.
The switch has a virtual interface (VIF) mapped to each identifier/VN-Tag.
From a switching point of view the switch treats the virtual and physical interfaces the same.
withdrawn
8 /21
National Tsing Hua University
VM-VM communications
9 /21
National Tsing Hua University
Proposed nSwitch design
We present two designs of nSwitch which reflect VM-VM traffic on the same computer.
These designs differ in terms of implementation complexity and functionality. Design 1, is a single Ethernet port NIC. Design 2, has two Ethernet ports.
Both designs support multiple CPUs and multiple socket logic boards.
10 /21
National Tsing Hua University
A. nSwitch Design for Single Port SR-IOV NIC Architecture
11 /21
vMA C VF #
F0-F0-F0-00-00-01 VF 0,1
F0-F0-F0-00-00-02 VF 0,2
F0-F0-F0-00-00-03 VF 0,3
F0-F0-F0-00-00-04 VF 0,4
Table A :
ab-cd-ef-12-34-56
National Tsing Hua University
Pseudo Code for nSwitching in the Synopsys (SR-IOV) core.
Initial state VF 0,3 associated with VM3; PF 0 associated with PCIe routing function allocating bandwidth data path and switching
functionality between VMs; Create table space (Table A) to associate a MAC Address with a given VF
Initialization of VM interfaces: vMAC offered to VMs will have a consistent MAC Address OUI based on the PF number
• (e.g. VF 0,3 assigns vMAC3 an OUI F0-F0-F0, VF 0,4 assigns the same to vMAC4); Insert MAC Address into Table A and associate with a given VF
Steady State Upon receipt of frame from a VF, compare source and destination OUI, prioritize based on
802.1p marking from VM. Case 1: equal source and destination OUI, look up the destination VF and route packet to that
VF for the associated VM; Case 2: unequal source and destination OUI, send to PCIe port; Case 3: Follow SR-IOV for receipt of a frame from PCIe port
12 /21
National Tsing Hua University
B. nSwitch Design for Multiple Port SR-IOV NIC
13 /21
8.0 GigaTransfers/second
National Tsing Hua University
C. Benefits of nSwitching
The addition of nSwitching to SR-IOV will reduce CPU loads and eliminate the need for bandwidth between the NIC and pSwitch for inter-VM traffic internal to the serve
Compared with the software-based vSwitch, there are many benefits to switching in hardware by using nSwitching: Eliminate CPU utilization increase caused by inter-VM I/O traffic and remove NIC bandwidth
constraint. Enable application of Access Lists (ACLs) and Quality of Service (802.1p) without CPU
performance hit. Enable VM-VM frame monitoring and control using MAC Address Organizational Unit
Identifier (OUI).This will eliminate the CPU workload problems created by inter-VM switching in
the hypervisor or vSwitch, and the bandwidth, latency and reliability problems created by switching in the pSwitch
14 /21
National Tsing Hua University
Evaluation
Software, hardware, platform profiling tools and VM with several operating systems were used for switching methods evaluation.
In this paper, we compare existing vSwitch with an approximation of 802.1Qbh and the proposed nSwitch.
Investing capital in any new core in silicon would be cost prohibitive without the intent to produce and sell the product, thus real implementation is beyond the scope of this paper.
15 /21
National Tsing Hua University
A. Testing Software, Hardware, Profiling Tools and VMs
Software: Citrix(r) XenServer(tm)11 5.6 FP1 with Open vSwitch was chosen for accelerated I/O
virtualization and a paravirtualized guest. The VM operating systems used were Redhat Beta 6 and Ubuntu 10.10 Maverick Meerkat.
Hardware: Directed I/O, Virtualization Technology for Directed I/O (VT-D) and SR-IOV were integrated
in the main board, Ethernet card and Processor. The hardware was special built by us as the features are not yet combined in a single platform.
Platform profiling tools: Linux top, dstat, md5sum for load and CPU Limit. Xen uses Open vSwitch. The Redhat VMs were given 1G RAM and 4 GB of hard drive. VMs also used Ubuntu 10.10.
16 /21
National Tsing Hua University
B. vSwitch: Bandwidth, Delay and CPU Load with 2 VMs
17 /21
Increase 20 %
National Tsing Hua University
C. pSwitch: Bandwidth, Delay and CPU Load of 802.1Qbh
18 /21
National Tsing Hua University
C. pSwitch: Bandwidth, Delay and CPU Load of 802.1Qbh
19 /21
National Tsing Hua University
D. Proposed nSwitch approximation: Bandwidth, Delay andCPU Load testing
20 /21
0.009 ms = 9 us
National Tsing Hua University
Conclusion
We have presented a method of using SR-IOV functions in the nSwitching design and proposed that it is feasible to investigate the detailed implementation nSwitching in existing SR-IOV core structures.
nSwitch is shown to be able to reduce CPU utilization over the vSwitch and decrease latency.
Comparing with 802.1Qbh or Qbg, inter-VM transmission speed will not be limited by the Ethernet port speed.
One of the primary benefits for nSwitching is that it eliminates any load created on the CPU due to switching in the hypervisor and the changes to the switch infrastructure as required by other edge switching technologies.
VM-VM traffic is Transparent ?Evaluation is enough?Algorithm is correct ?
21 /21