Automatic Vacuum Calibration System
Industry first fully automatic system will help you meet the
ever-challenging need for precision calibration. The fully
automatic, dedicated system with patent pending pressure
control algorithm, integrated controls and calibration software
will provide you with the fast, repeatable yet cost effective
approach to calibration of vacuum gauges.
ISO 3567 compliant system will provide you with Consistent,
Reliable and Traceable data, freeing valuable time and
resources.
One Westinghouse Plaza
Boston, MA 02136
U.S.A.
Tel: 617.364.0400
Fax: 617.364.5477
potomacelectric.com/vacuum
© Vacuum Systems 2012
Specifications:
ISO Standard Compliancy ISO 3567
Transfer Standards: Up to 3 Baratron® 690A
Test Port Connections: KF16 (8 VCR® optional)
Power Requirements: 120/230 VAC, 50/60 Hz, 15A
Air (for Automation): 6 bars (90 psi)
Nitrogen or Air (for Calibration): .35 bar (5 psi), filtered, dry
Operating System: Windows® 7
Display: 22” (1920x1080)
Weight: 180 kg (400lbs)
Intuitive User Interface Developed Specifically for AVCS, the user interface provides clear, real time information of
system status, process steps and faults.
Pressure Control Range 1.3x10-3 to 1.3x10+5 Pa (1x10-5 to 1000 Torr)
Pressure Control Accuracy Up to 0.01% of set point (patent pending pressure control algorithm)
Control Resolution
Up to 0.01% of set point, user adjustable
Test Gauges Data Input
3 dedicated RS232 ports
3 dedicated analog inputs (optional)
Data Averaging
10 to 99 points
Thermal Transpiration Compensation
Transfer Standards: ON/OFF selector
Test Gauges: ON/OFF selector (parameters entered on Test Gauge setup screen)
Test Gauges and Test Parameters Data
Unlimited Test gauges and Test Flow Recipe data is stored in SECURED database
Data Security
Every operational step is logged for future reporting, analysis and clear audit trail.
User configurable access levels and data protection
PRECISION AND CONTROL AT YOUR FINGERTIPS 3 OPERATING MODES AND SERVICE MODE PROVIDE NEEDED FLEXIBILITY
Automatic mode:
Automatic set point selection based on entered number of set points per decade
Automatic test flow from lowest to highest pressure set point
Semi-Automatic mode:
Manual set points selection for the test
Automatic test flow from lowest to highest pressure set point
Manual mode:
Manual set points entry at random (one at a time)
Automatic pressure control for a selected set point. Each consecutive set point can be set higher or lower than the previous one.
Service Mode:
Manual input control for all automation components and Transfer Standards controller
Step by step system calibration and troubleshooting
DESIGN FEATURES High Accuracy Transfer Standards Up to 3 NIST traceable Baratron® 690A gauges with basic accuracy of +/-0.05% of the reading
Dry Pumping System Scroll and Turbomolecular pumps
Base Pressure Less than 7x10-5 Pa (5x10-7 Torr)
Number of Test Ports 3
Number of Simultaneously Tested Gauges 3, various types
Process Gas Nitrogen or Dry Air
Cleanroom Compatibility Fully compatible
SAFETY FEATURES Transfer Standards and Test Gauges Safety FAIL SAFE Isolation valves keep Transfer Standards and Test Gauges within specified pressure ranges AT ALL TIMES
System Safety PC controls process flow and data collection only;
Industrial grade PLC controls automation and safety
CONTROLS AND SOFTWARE FEATURES
REMOTE FEATURES Remote Data Access Optional remote notifications of
system status and faults via text
message or dedicated application
Optional SECURE remote data access
via Android® tablets or iPad®.