AUTOMATIC VOLTAGE REGULATOR The input plug and output socket are subject to change according to different country and area. IF THE INPUT VOLTAGE IS IN THE RANGE OF 190-250V, THE REGULATOR IS ABLE TO PROVIDE 100% LISTED MAXIMUM OUTPUT POWER. MAXIMUM OUTPUT POWER WILL CHANGE AS THE CURVE SHOWN BELOW. 1. Digital display meters are more accurate, stable and easy to read the voltage status at a glance. 2. This unit comes with individual circuit breakers for both input and output voltage along with dual switches which ensures double protection. 3. This unit has a built-in new generation Japanese CPU, which ensures consistency and stability to the AVR unit. Characteristic PRECISION SELECTOR The default position is 10%. When you press down the Precision Selector Button, the precision will be 8%. When the regulator start up, the output meter will indicate the count-down delay time. The default delay time is 6sec. If you press down the Delay Selector Button, the delay time will be 120sec.After time-delaying, it will indicate the normal output voltage. Within the precision range it will display 220V, and when out of the precision range (for 8% precision: 204V~236V; for 10% precision:198V~242V), it will indicate the current output voltage. When pressing the Delay Selector Button, it will display the current delay time(6sec or 120 sec) for 3 seconds, then return to indicate the input voltage. When pressing the Precision Selector Button, it will display "PCL" when the current precision is 10%, and will display "PC H" when it's 8%. If the output voltage is over 255V for 3 seconds, it will display a flashing "H", and if the output voltage is under 180V for 1 seconds, it will display a flashing "L". s This is the general power switch of the regulator. POWER PROTECTED SWITCH Shows the input voltage. If this regulator is used for refrigerant appliance, please select "DELAY", so as to minimize the opportunity of damage to the motor compressor. If not, please select "UNDELAY". DELAY/UNDELAY SELECTOR 05 04 02 03 01 When the " WORKING " indicator is lit, the regulator is working. WORKING When the "UNUSUAL" indicator is lit, the output voltage is over 255+/-5V, the protective circuit will start and the regulator will have no output, when the output voltage is under 245+/-5v, the regulator will automatically resume output. UNUSUAL "DELAYING LED" will keep flashing when delaying .When delaying is over, flash will stop and LED will light up. DELAYING 220V+/-10% 140V to 260V 50Hz 50Hz 1000VA 500VA 4.5A 2.3A 8A 3A 10A 12A 6.8A 9.1A 13.6A 22.7A 36.3A 45.5A 1500VA 2000VA 3000VA 5000VA 8000VA 10000VA 500VA 1000VA 1500VA 2000VA 3000VA 5000VA 8000VA 10000VA OVERLOAD PROTECTION 25A 16A 32A 40A INPUT : AC 140~260V 06 INDICATOR Use the same current fuse for replacement WORKING DELAYING UNUSUAL 888 DIGITAL TECH-SYSTEM INPUT VOLTAGE 888 220 DIGITAL TECH-SYSTEM OUTPUT VOLTAGE RE02-2000VA INPUT: 140-260V OUTPUT: 220V WORKING DELAYING UNUSUAL 888 DIGITAL TECH-SYSTEM INPUT VOLTAGE 888 220 DIGITAL TECH-SYSTEM OUTPUT VOLTAGE DELAY UNDELAY ON OFF RE02-5000VA INPUT: 140-260V OUTPUT: 220V 8% 10% 01 02 INPUT METER OUTPUT METER 03 INDICATOR 05 DELAY/UNDELAY SELECTOR 06 POWER SWITCH 04 PRECISION SELECTOR WORKING DELAYING UNUSUAL DELAY UNDELAY 8% 10% 888 DIGITAL TECH-SYSTEM INPUT VOLTAGE 888 220 DIGITAL TECH-SYSTEM OUTPUT VOLTAGE RE02-2000VA INPUT: 140-260V OUTPUT: 220V OUTPUT : AC 220V

AUTOMATIC VOLTAGE REGULATORdownload.mo.ro/public/User-Manual/4209/voltage-regulator... · AUTOMATIC VOLTAGE REGULATOR The input plug and output socket are subject to change according

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AUTOMATIC VOLTAGE REGULATORdownload.mo.ro/public/User-Manual/4209/voltage-regulator... · AUTOMATIC VOLTAGE REGULATOR The input plug and output socket are subject to change according

AUTOMATIC VOLTAGE REGULATOR

The input plug and output socket

are subject to change according

to different country and area.

IF THE INPUT VOLTAGE IS IN THE RANGE OF 190-250V, THE REGULATOR IS ABLE TO PROVIDE 100% LISTED MAXIMUM OUTPUT POWER.MAXIMUM OUTPUT POWER WILL CHANGE AS THE CURVE SHOWN BELOW.

1. Digital display meters are more accurate, stable and easy to read thevoltage status at a glance.

2. This unit comes with individual circuit breakers for both input and outputvoltage along with dual switches which ensures double protection.

3. This unit has a built-in new generation Japanese CPU, which ensuresconsistency and stability to the AVR unit.

Characteristic

PRECISION SELECTOR

The default position is 10%. When you press down the Precision Selector Button, the precision will be 8%.

When the regulator start up, the output meter will indicate the count-down delay time. The default delay time is 6sec. If you press down the Delay Selector Button, the delay time will be 120sec.After time-delaying, it will indicate the normal output voltage. Within the precision range it will display 220V, and when out of the precision range (for 8% precision: 204V~236V; for 10% precision:198V~242V), it will indicate the current output voltage.

When pressing the Delay Selector Button, it will display the current delay time(6sec or 120sec) for 3 seconds, then return to indicate the input voltage. When pressing the Precision Selector Button, it will display "PCL" when the current precision is 10%, and will display "PCH" when it's 8%.

If the output voltage is over 255V for 3 seconds, it will display a flashing "H", and if the output voltage is under 180V for 1 seconds, it will display a flashing "L".

s

This is the general power switch of the regulator.

POWER PROTECTED SWITCH

Shows the input voltage. If this regulator is used for refrigerant appliance, please select "DELAY", so as to minimize the opportunity of damage to the motor compressor. If not, please select "UNDELAY".

DELAY/UNDELAY SELECTOR

05

04

02

03

01

When the " WORKING " indicator is lit, the regulator is working.WORKING

When the "UNUSUAL" indicator is lit, the output voltage is over 255+/-5V, the protective circuit will start and the regulator will have no output, when the output voltage is under 245+/-5v, the regulator will automatically resume output.

UNUSUAL

"DELAYING LED" will keep flashing when delaying .When delaying is over, flash will stop and LED will light up.

DELAYING

220V+/-10%140V

to260V

50Hz 50Hz

1000VA

500VA

4.5A

2.3A

8A

3A

10A

12A

6.8A

9.1A

13.6A

22.7A

36.3A

45.5A

1500VA

2000VA

3000VA

5000VA

8000VA

10000VA

500VA

1000VA

1500VA

2000VA

3000VA

5000VA

8000VA

10000VA

OVERLOAD PROTECTION

25A

16A

32A

40A

INPUT : AC 140~260V

06 INDICATOR

Use the same current fuse for replacement

WORKING

DELAYING

UNUSUAL

DELAY

UNDELAY

8%

10%

888DIGITAL

TECH-SYSTEM

INPUT VOLTAGE

888220DIGITAL

TECH-SYSTEM

OUTPUT VOLTAGE

RE02-2000VAINPUT: 140-260VOUTPUT: 220V

WORKING

DELAYING

UNUSUAL

888DIGITAL

TECH-SYSTEM

INPUT VOLTAGE

888220DIGITAL

TECH-SYSTEM

OUTPUT VOLTAGE

DELAY

UNDELAYON

OFF

RE02-5000VAINPUT: 140-260VOUTPUT: 220V

8%

10%

01

02

INPUT METER

OUTPUT METER

03

INDICATOR

05

DELAY/UNDELAY SELECTOR

06

POWER SWITCH

04

PRECISION SELECTOR

WORKING

DELAYING

UNUSUAL

DELAY

UNDELAY

8%

10%

888DIGITAL

TECH-SYSTEM

INPUT VOLTAGE

888220DIGITAL

TECH-SYSTEM

OUTPUT VOLTAGE

RE02-2000VAINPUT: 140-260VOUTPUT: 220V

OUTPUT : AC 220V