40
Alcatel BSS B9 BSS Methods Handbook BSS Document Procedural Handbook Release B9 3BK 17422 0002 PCZZA Ed.20P01

B9 BSS Methods Handbook ed20.pdf

Embed Size (px)

Citation preview

  • Alcatel BSS

    B9 BSS Methods Handbook

    BSS Document

    Procedural Handbook

    Release B9

    3BK 17422 0002 PCZZA Ed.20P01

  • Status IN PREPARATION

    Short title B9 BSS Methods Handbook

    All rights reserved. Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel/Evolium.

    BLANK PAGE BREAK

    2 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • Contents

    ContentsPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Elementary Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    1.1 From BSC Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.1.1 Load BSS Software from BSC Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.1.2 Off-line Hardware Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.1.3 BSC Reloading Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.1.4 A9130 BSC Evolution DLS Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    1.2 From Transmission Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141.2.1 Verify Alarms on ATBX Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141.2.2 Verify Alarms on ASMC Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141.2.3 Local Download of Generic Settings for G2TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    1.3 From the BTS Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161.3.1 Call Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161.3.2 Locally Load Software on A9100/A9110 BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    1.4 Program Initial Transmission Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191.4.1 G1 BTS (MKII), G2 BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191.4.2 A9100 BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    1.5 Common Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201.5.1 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201.5.2 Technical Level of Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201.5.3 Connect BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.5.4 Disconnect BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.5.5 Connect Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.5.6 Disconnect Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231.5.7 Change Abis Port from One Port to Another . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    2 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.1 Faults and Anomalies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    2.1.1 ALCATEL 3000 Failure Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.1.2 Fault Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    2.2 Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.2.1 General Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.2.2 Safety Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.2.3 Safety Requirements IEC 950 (Excerpt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.2.4 Safety Rules for Equipment Under Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.2.5 Equipment Emitting RF Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.2.6 Electrostatic Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    2.3 Fill In a CCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 3 / 40

  • Contents

    4 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • Preface

    PrefacePurpose This Methods Handbook presents a list of tasks that are defined for the control

    and maintenance of the Alcatel BSS for the mobile communication network.This document applies to operational BSS from Release B9.

    Whats New In Edition 20Section 1.1 From BSC Terminal was modified.Section A9130 BSC Evolution DLS Restore (Section 1.1.4) was added.

    In Edition 02Document update for A9130 BSC Evolution and A9130 MFS Evolution inFill In a CCL (Section 2.3).

    In Edition 01Document creation in B9.Update for the masterfile B8, B9 in Load BSS Software from BSC Terminal(Section 1.1.1)

    Audience This document is intended for:

    Commissioning personnel

    System support engineers (specialists)Field service technicians.

    Assumed Knowledge Personnel must be familiar with:

    Alcatel Operations and Maintenance concepts for the BSS

    BSC, TC, BTS hardware configurations

    Installation and commissioning tools

    PCs in a Windows environment.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 5 / 40

  • Preface

    6 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    1 Elementary Tasks

    This chapter presents elementary tasks to be performed on BTS, BSC, andTC sites before, during, and after commissioning.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 7 / 40

  • 1 Elementary Tasks

    1.1 From BSC TerminalNote: The following tasks are done with the BSC Terminal running on Windows

    2000/XP.

    1.1.1 Load BSS Software from BSC TerminalTwo cases apply:

    C1: Loading the BSS Software with the files stored on the diskettes(quantity=7) that were created during the complete backup from the OMC-R(DISK_A + DISK_B + DISK_C)C2: Loading the BSS Software with the SDP Package and the first diskettethat was created during the partial backup from the OMC-R (DISK_A).

    Load BSS Software from

    BSC Terminal

    To load the BSS Software from the BSC Terminal,1. Create a directory for either the B9 gzip files (C1), or the SDP Package files

    and the B9 gzip files from the first diskette (C2).Create a target directory (example: C:\target_name)Copy gzip.exe from C:\Alcatel\ProgramFiles\Alcatel\WinBSC\B9 tothe target directory

    For C1: Copy all compressed files (gzip) from back-up diskettes tothe target directory

    For C2: Copy the SDP Package files and the files from the first back-updiskette in the target directory

    Open a Command Prompt window on the BSC terminal

    Select the target directory: cd C:\target_name

    Uncompress the gzip files: gzip -dvN *.gz.

    2. Disable BSC.From the BSC terminal menu bar, follow the menu path:Commands -> Equipment Handling-> SBL DisableObject Class: SBLUnit Type: BSC, Unit Number: 1SBL Type: BSC, Nbr: 1, SubNbr: 255WTC (Wait Traffic Clear): 0Click on [ OK ].

    3. Format disk A (CPRA system A, subrack 8, slot 27).From the BSC terminal menu bar, follow the menu path:Commands -> Disk operations -> Format SSDDirectory path: C:\target_nameAvailable file: Select the BSS masterfile name (MZQxx.xxxfor B6 or MZTxx.xxx for B7 or MZVxx.xxx for B8 orMZWxx.xxx for B9)Destination disk: Disk A:Click on [ Go! ].

    8 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    4. Load the BSS software on disk A.From the BSC terminal menu bar, follow the menu path:Commands -> Disk operations -> File transfer from PC to BSC.Directory path: C:\target_nameAvailable file: Select the BSS masterfile name (MZQxx.xxxfor B6 or MZTxx.xxx for B7 or MZVxx.xxx for B8 orMZWxx.xxx for B9).Destination disk: Disk A:Click on [ Go! ].

    5. Format disk B (CPRA system B, subrack 8, slot 31)From the BSC terminal menu bar, follow the menu path:Commands -> Disk operations -> Format Duplex SSD.Source-destination-disk: from DISKA: to DISKB:Click on [ OK ].

    6. Copy the BSS software to Disk B (CPRA system B, subrack 8, slot 31).From the BSC terminal menu bar, follow the menu path:Commands -> Disk operations -> File Transfer from BSC to BSC.Source disk: Disk A:Destination disk: Disk B:Select Click on [ OK ].

    7. Activate loading of the BSC.From the BSC terminal menu bar, follow the menu path:Commands -> System Activation -> System Initialization.Unit Identity: BSCUnit Number: 01Init Level: REBOOTClick on [ OK ].

    8. Wait for the BSC to complete its startup.9. Check that the contents of both disks are identical.

    From the BSC terminal menu bar, follow the menu path:Commands -> Disk operations -> Control SSDAction: DISK INFORMATIONInvolved SSD: Disk AClick on [ OK ].From the BSC terminal menu bar, follow the menu path:Commands -> Disk operations -> Control SSDAction: DISK INFORMATIONInvolved SSD: Disk BClick on [ OK ]Compare the two results: there has to be the same number of files.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 9 / 40

  • 1 Elementary Tasks

    1.1.2 Off-line Hardware TestBefore the BSC can be tested, it must be in the idle state, with the software inall the Control Elements (CE) running in the idle mode.

    Test Procedure: 1. Reboot the BSC in OFF-LINE TEST mode.2. Trigger the BSC hardware test.3. Reboot the BSC in OPERATIONAL mode.

    Reboot the BSC in

    OFF-LINE TEST Mode

    1. Select the following menu path:Commands -> Commissioning Tests -> BSC System Test Init

    2. In Unit identity, select the parameter 3. In Unit Number, enter the parameter 4. In Initialization level, select the parameter 5. In Test Mode, select the parameter 6. In Autoconfiguration, select the parameter 7. Click on [ OK ].8. Wait about 10 minutes for the successful report. Verify that 94 CE

    (configuration 3) are equipped.Trigger the BSC

    Hardware Test

    Select the following menu path: Commands -> Commissioning Tests ->TestFacilities for G2Network test1. Select 2. In Test, select the parameter 3. In Source, select the parameter 4. In Tunnel, select the parameter 5. In Destination, select the parameter 6. In Port, select the parameter 7. In Loop, select the parameter 8. Click on [ OK ].9. Wait for the successful report.Broadcast test1. Select 2. In Test, select the parameter 3. In All CEs, select the parameter 4. In Loop, select the parameter 5. Click on [ OK ].6. Wait for the successful report.

    10 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    Clock test1. Select 2. In Test, select the parameter 3. In Transmission, select the parameter 4. In External Ref, select the parameter 5. In Loop, select the parameter 6. Click on [ OK ].7. Wait for the successful report.

    Note: If any hardware test fails, try to identify the problem and fix it. Repeat all thehardware tests. If a test still fails, check the inter-rack cabling between the racks.

    Reboot the BSC in

    OPERATIONAL Mode

    1. Select the following menu path:Commands -> Commissioning Tests -> BSC System Test Init.

    2. In Unit identity select the parameter 3. In Unit Number select the parameter 4. In Initialization level select the parameter 5. In Test Mode select the parameter 6. In Autoconfiguration select the parameter 7. Click on [ OK ].8. Wait approximately 10 minutes for the successful report.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 11 / 40

  • 1 Elementary Tasks

    1.1.3 BSC Reloading TestDisconnect/Reconnect

    Main Power Supply

    1. Switch OFF all the rack circuit breakers. No LED is lit.2. Switch ON all the rack circuit breakers. All the boards run the self test

    and reload.

    The TCU 1, DTC 1, and CPRCs 3, 4, 5, and 6 boards are loaded byCPRC boards 1 and 2

    The loaded TCU and DTC board then load the remaining TCU andDTC boards (cascade loading). When loading is complete all boardsare ready to start

    The loading procedure is indicated by the LEDs on the board frontpanels. Refer to Hardware Information, which describes the variousLED states for the different boards.

    Check BSC Loading Generate and print out the states of the faulty SBLs.1. Select the following menu path:

    Commands -> Equipment Handling -> SBL State List2. In Object Class, enter the parameter 3. In Unit Type, enter the parameter 4. In Unit Number, enter the parameter 5. Click on [ OK ].6. Check that all the CPR, DTC, TCU, and SWITCH SBLs of the BSC are In

    Traffic. They should not appear in the State List command report.

    Print Out Content of

    Each BSC Disk

    1. Select the following menu path:Commands -> Disk Operation -> Control SSD

    2. In Action field enter 3. In Involved SSD enter 4. Click on [ OK ].5. Use the arrow keys to move up and down through the reports. Select the

    necessary report.6. Select the following menu path:

    File ->Print7. When a message appears, click on [ OK ]. The Notepad program opens

    and the report appears.8. In the Notepad program, select the following menu path:

    File ->Print to print the report.9. Repeat Steps 1 to 8 for Disk B.

    10. Compare the contents of Disk A and Disk B (number, FID, and file name)in the print out of CONTENTS.LST. The contents of the two disks mustbe the same.

    If the contents of disks A and B are different, then the content of the activeCPRC board must be loaded on the inactive (stand-by) CPRC board.

    12 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    1.1.4 A9130 BSC Evolution DLS RestoreTo copy the DLS file from PC to BSC:1. Transfer the DLS file from PC to both OMCP boards, in the

    /common/bsc/SCPRDISK directory , as described in Transferring Files andthen confirm the old DLS file have been replaced.

    There can be used another secure method for FTP transfer between PCand OMCPs.

    To activate the restored DLS:2. From the BSC Terminal menu bar, follow the menu path:

    Commands -> Equipment Handling -> SBL Reset3. In the Object Class field, select the parameter 4. In the Unit Type field, select the parameter 5. In the SBL Type field, select the parameter 6. In the Unit Number field, type 7. In the Nbr field, type SBL number 8. In the SubNbr field, type the SBL sub-number 9. Click on [ OK ].

    Impact on System Supervision and all telecommunications resources are lost when the restoredDLS is activated on BSC.To verify status of A9130 BSC with restored DLS:

    10. From the BSC Terminal menu bar, follow the menu path:Commands -> Equipment Handling -> SBL Read Status

    11. In Object Class field, select the parameter 12. In Unit Type field, select the parameter 13. In the SBL Type field, select the parameter 14. In Unit Number field, type 15. In the Nbr field, type SBL number 16. In the SubNbr field, type the SBL sub-number 17. Click on [ OK ].

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 13 / 40

  • 1 Elementary Tasks

    1.2 From Transmission Terminal

    1.2.1 Verify Alarms on ATBX Boards1. Connect the PC to the ATBX using the RS-232 cable.2. Double-click on the [ Transmission Terminal Program ] icon. The

    Transmission Terminal Password window appears.3. Enter the Password (if any) and click on [ OK ]. The Alcatel Main Menu

    appears.4. Select Session -> Connect

    The ATBX Connection Established window appears.5. Click on [ OK ]. The Main Menu appears again.6. Select Services -> Alarm Collection

    If the connection is OK, no active alarms appear.

    If Alarm Collection indicates a Loss of CRC multiframe alignment alarmlocated on the MSC site, verify that the CRC4 is disabled on the A-Trunk MSC.

    1.2.2 Verify Alarms on ASMC Boards1. Connect the PC to the ASMC using the RS-232 cable.2. Double-click on the [ Transmission Terminal Program ] icon. The

    Transmission Terminal Password window appears.3. Enter the Password (if any) and click on [ OK ]. The Alcatel Main Menu

    appears.4. Select Session -> Connect

    The ASMC Connection Established window appears.5. Click on [ OK ]. The Main Menu appears again.6. Select Services -> Alarm Collection

    If the connection is OK, no active alarms appear.

    If Alarm Collection indicates a Loss of CRC multiframe alignment alarmlocated on the MSC site, verify that the CRC4 is disabled on the A-Trunk MSC.If Alarm Collection indicates a Loss of incoming 2M signal or an AIS 2Malarm, verify the PCM connection on DDF.

    14 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    1.2.3 Local Download of Generic Settings for G2TC1. Start the LMT-CT software.2. Enter the Password (if any) and click on [ OK ]. The Alcatel Main Menu

    appears.3. Select the following menu path: Session -> Connect

    The Connection Established window appears.4. Click on [ OK ]. The Main Menu appears again.5. Select the following menu path: Service -> Data -> Download6. Click on [ Browse ].7. To chose the file to download, go to the LMTCT\B9 directory and select

    one of the following paths:

    G2 TC, ASMC board: LMTCT\B9\Settings\G2\\ASMC\\\RACK\SHELF\SLOT

    G2 TC, ATBX board: LMTCT\B9\Settings\G2\ \ ATBX \ \\RACK\SHELF\SLOT .

    8. Click on [ OK ] and wait for the file to download.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 15 / 40

  • 1 Elementary Tasks

    1.3 From the BTS Terminal

    1.3.1 Call TestNote: In case of an extended cell, tests must be performed at a distance of about

    30Km from the BTS site.

    Identify Signaling Using

    the BTS Terminal

    1. Connect and start the BTS Terminal.2. Select the following menu path: BTS Terminal Window -> Show -> Logical

    Configuration -> Radio Channel Configuration.3. The BTS_LOG_CONFIG_REQUEST window is displayed.4. Check that the radio channels are assigned as signaling links and traffic

    channels (FCCH, SCH, BCCH, CCCH, SDCCH, SACCH, TCH).Unlock Cell under Test 1. At the BTS Terminal, unlock the impacted cell:

    BTS Terminal Window -> Commands -> SBL Management2. Select for SBL ID.3. Click on [ Init ].4. Wait for the successful SBL Init report.

    Activate Mobile Trace

    Function

    Check the handling of radio calls in the time slots of each FU:

    Make radio calls on all the time slots (RTS) of each FUMake one incoming call on each BTS from a fixed station (ask somebody tocall you)Check speech quality in both directions (subjectively)Make calls to the voice mailbox for all the remaining time slots.

    1. For each call, check on the trace mobile that the call is handled by the BTS.2. Check the cell number (hexadecimal).3. Check the used BCCH frequency.4. Check the used radio resource radio channel (ARFCN).5. Check the time slot (TN).

    Note the result of each call.

    16 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    1.3.2 Locally Load Software on A9100/A9110 BTS

    If the BTS is connected to the Abis, you cannot perform this procedure.

    To download the BTS from the BTS terminal:1. Start the BTS Terminal:

    Connect the PC to the SUM board (between COM1 or COM2 and BTSTERMINAL connector) using the BTS terminal cableLaunch the BTS Terminal:Start -> Programs -> BTS-Terminal release B9 -> BTS-Terminalrelease B9

    At the BTS Terminal: User/Group name: UPGRAD Password: SUMSUP

    Click on [ Logon ].

    2. Set the serial interface parameters and the path to Inventory software, ifnot already done:

    Settings -> Terminal

    Under the Serial Interface tab, select the right port (COM1 or COM2)and baud rate of 115200

    Select the Misc tab, and if not already done, click on [ Browse ] and selectthe path to INVENTAR (usually c:\WINVENT\Program\pwinvent.exe)Click on [ OK ].

    3. Establish the connection:File -> Connect/DisconnectThe connection to the OMU has been established! messageappears.

    4. OPTION: Only if the files are not already on the PC:

    Create a directory: C:\bts_files

    Copy all the files to the directory from the diskette.

    5. Download the BTS with the BTS terminal:

    Commissioning ->Download-> BTS-SW ...

    Master File: BM*SAT**.MSF; CPF File: 00o*AT**.DDL; CODA File:CODA.990 ; The CODA.990 is in the directory C:\bstw\B9\commtest.Click on [ Browse ] to give the path of each file: C:\bts_filesClick on [ Download ].

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 17 / 40

  • 1 Elementary Tasks

    6. Check the downloading of the BTS:

    A disconnection appears during download. Wait until the message Theconnection to the OMU has been established! appears

    Some messages/windows may appear during download, such as: Nooperator action during next 80 seconds!!!, BTS SW downloadin progress..., Start operational software..., No operatoraction during next 80 seconds!!!, BTS SW download inprogress..., Initialization in progress....

    7. BE PATIENT: WAIT for the Edit frequencies window:

    Select the Frequency band (GSM 900/DCS 1800/DCS 1900/EGSM)Select the test frequencies by clicking on [ Add ] or [ Remove ] in theAvailable ARFNs list to have the correct frequencies in the SelectedARFNs list

    Click on [ Submit ].

    8. Create and initialize sector:

    To create the sectors: Commissioning->Edit Sector Mapping

    Click on [ SAVE ]To initialize sectors: Commissioning->Initialization->All sectors

    Commissioning->End Commissioning

    Some automatic actions start. At the end a message appears: Doyou want to execute INVENTAR now? (This is the lastpossibility before BTS-Auto-Reset)

    Click on [ YES ] to perform a Remote Inventory.

    18 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    1.4 Program Initial Transmission Settings

    1.4.1 G1 BTS (MKII), G2 BTSREMARK: For a G1 BTS, the transmission setting files for the initialprogramming are delivered with the program. Refer to the following table todetermine which file has to be downloaded according to the field configuration.

    File name Number ofSMBS boards

    Qmux onTS

    R bit on TS S bit onTS

    OnDirectory/SETTINGS/G1/MKIIBTS

    q01r_.hex 1 01 No S bit No R bit ONE_SMBS/

    q18r31.hex 1 18 17 31 ONE_SMBS/

    q16r31.hex 1 16 15 31 ONE_SMBS/

    q01r02.hex 1 01 17 02 ONE_SMBS/

    q01r_.hex 2 01 No S bit No R bit TWO_SMBS/

    q18r31.hex 2 18 17 31 TWO_SMBS/

    q16r31.hex 2 16 15 31 TWO_SMBS/

    q01r02.hex 2 01 17 02 TWO_SMBS/

    q00r31.hex 2 00 00 31 TWO_SMBS/

    Establish Connection to

    Local Board

    1. Connect the Transmission Terminal to the local board of the BTS.2. Disconnect the PCM cables to isolate the transmission module before

    trying to establish a connection.3. Start the Transmission Terminal software. Click on [ OK ] when the password

    is requested.4. Select the menu path Session-> Connect5. Select Broadcast Address. Click on [ OK ] when the broadcast warning

    window is displayed.6. Wait until the connection is established.

    Download Transmission

    Files

    1. Select the menu path File- > Download2. Select the required data file. Click on [ OK ]. Wait until the download is

    finished.3. Disconnect from the board: select the menu path File -> Disconnect4. Disconnect the cable from the board. Reconnect the PCM cables to the local

    board of the BTS.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 19 / 40

  • 1 Elementary Tasks

    1.4.2 A9100 BTSThe download of the transmission files can be performed in two ways:

    Download files generated by the OMC-R

    Download files created with the A9100 BTS Terminal.

    Download Files

    Generated by OMC-R

    1. Connect the A9100 BTS Terminal to the local board (SUM) of the A9100BTS.

    2. Disconnect the Abis link cables before trying to establish a connection.

    3. Start the A9100 BTS Terminal software.4. Select the menu path Settings-> Transmission5. Click on [ Download ]. In the Open File window, select the required data

    file. Click on [ OK ].Download Files Created

    with A9100 BTS Terminal

    1. Connect the A9100 BTS Terminal to the local board (SUM) of the A9100BTS.

    2. Disconnect the Abis link cables before trying to establish a connection.

    3. Start the A9100 BTS Terminal software.4. Select the menu path Settings -> Transmission5. Click on Initial settings. Click on [ Get Config ].6. Insert the values for the following fields: Qmux address, Qmux in TS (1),

    Baud rate (1200).7. Click on [ Transmit ].8. Wait until the download is successfully finished.

    1.5 Common Tasks

    1.5.1 InventoryFor each subrack, check for the presence, number, type, and layout of theboards against the Hardware Configuration site documentation.

    1.5.2 Technical Level of HardwareCheck each boards technical release level marked on the label against theBSS hardware technical release document.

    20 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    1.5.3 Connect BTS

    Figure 1: Connecting the BTS to the BSC

    1. Locate the Alcatel Digital Distribution Frame (DDF).2. Use the labels on the DDF to find the two positions, Emission and Reception,

    of the Abis link (link A) of the BTS.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 21 / 40

  • 1 Elementary Tasks

    3. If the BTS is:

    First on the chain: Connect the PCM from the first Abis link (link A) of theBTS in the DDF according to the correct position of the BTS

    In the middle of the chain: in the DDF, connect the PCM from the firstAbis link (link A) of the BTS to the second Abis link (link B) of the previousBTS. Ensure that the jumper connection between the two Abis links ofthe BTSs is done according to the following rule:

    The emission of the Abis link A is connected to the reception of theAbis link BThe reception of the Abis link A is connected to the emission ofthe Abis link B.

    1.5.4 Disconnect BTS1. Locate the Alcatel Digital Distribution Frame (DDF).2. Use the labels on the DDF to find the two position, Emission and Reception,

    of the Abis link (link A) for the BTS.3. If the BTS is:

    First on the chain: disconnect the PCM from the first Abis link (link A) ofthe BTS from the DDF

    In the middle of the chain: in the DDF, disconnect the PCM from thefirst Abis link (link A) of the downstream BTS from the second Abis link(link B) of the previous BTS. Remove the jumpers between the two Abislinks of the BTSs from the DDF.

    1.5.5 Connect Jumper1. Locate the Alcatel Digital Distribution Frame (DDF).2. Use the labels on the DDF to locate the two positions, Emission and

    Reception, of the Abis link for the BTS.3. Insert a loop on the Emission position. Insert a loop on the Reception

    position.

    22 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 1 Elementary Tasks

    1.5.6 Disconnect Jumper1. Locate the Alcatel Digital Distribution Frame (DDF).2. Use the labels on the DDF to locate the two positions, Emission and

    Reception, of the Abis link for the BTS.3. Remove the loop from the Emission position. Remove the loop from the

    Reception position.

    1.5.7 Change Abis Port from One Port to Another1. Locate the Alcatel Digital Distribution Frame (DDF).2. Use the labels on the DDF to find the two positions, Emission and Reception,

    of the Abis link from the BSC.3. In the DDF, disconnect the PCM of the Abis link from the current position.4. In the DDF, insert the removed PCM to the new position of the Abis link.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 23 / 40

  • 1 Elementary Tasks

    24 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 2 General Information

    2 General Information

    This chapter contains safety rules and precautions that must be followedby all personnel during work time.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 25 / 40

  • 2 General Information

    2.1 Faults and Anomalies

    2.1.1 ALCATEL 3000 Failure ReportAny faulty components, supplies, or replacement parts must be returnedwith an ALCATEL 3000 FRD failure report form to the ALCATEL personresponsible for the operation

    The ALCATEL 3000 number must be entered in the Title column of theFaults reports/Actions form section of the CCL

    If a module from the replacement kit is used to replace a faulty moduleunrelated to the operation, the replacement must be noted in theManufacturers comments section of the CCL.

    2.1.2 Fault ReportsBugs found when preparing and carrying out work must be reported bycompleting and sending a fault report to the ALCATEL person responsible forthe operation on the site.

    2.2 Safety RulesThis chapter contains safety rules and precautions for:

    Installation personnel on the site

    Equipment under power

    Equipment emitting RF power

    Electrostatic precautions.

    Death or serious physical harm to personnel and damaged equipment mayresult by mishandling.Be familiar with the local safety requirements. Read the General SafetyInstructions.

    2.2.1 General Safety RequirementsAlways refer to local safety regulations and accident prevention

    In France, apply Labor Legislation and decree Nx92-158

    Obtain safety requirements linked to equipment during installation inaccordance with IEC 950.

    26 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 2 General Information

    2.2.2 Safety PrerequisitesThe following safety prerequisites apply:

    Customer Is able to warn the installation staff in case of danger

    Is able to communicate with the installation team via a direct line ofcommunication

    Is able to provide a list of collocated radiating equipment.

    Installation Team Inform the customer about:

    Date of arrival

    Duration of work

    Number of technicians on site

    Staff authorized to enter the site

    The contact person.

    Before You Start Before you start:

    Verify that the site inspection is done and that the results are documented inan inspection report

    Ensure good illumination in your place of work

    Indicate danger sources

    Verify that the compliance perimeter to electromagnetic field exposureis marked

    Be prepared to provide first aid

    Be familiar with the telephone numbers of:Fire brigadeHospitalPoliceCustomer contact person.

    Take into account special site risks

    Check working conditions on site.

    Do not work alone on site.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 27 / 40

  • 2 General Information

    2.2.3 Safety Requirements IEC 950 (Excerpt)The 230 V electrical supply must be recognizable

    The equipment power supply is protected by 300 mA circuit breakers

    The service point power supply is protected by 30 mA circuit breakers

    Do not extend the maximum load indicated at the service point

    Insure a proper protective earth connection (resistance

  • 2 General Information

    2.2.6 Electrostatic PrecautionsThe following electrostatics precautions must be observed:

    Environment Ensure that work benches, stools, and floor mats have a conducting surfaceconnected to the ground. Before handling static-sensitive components andassemblies, ground yourself to the conducting surface using an anti-staticwrist strap

    When handling static-sensitive components and assemblies, do not wearor use clothes made of wool, nylon, or any other synthetic material. Suchfabrics are major sources of static build upWhen handling static-sensitive components and assemblies, do not usegloves and finger covers, unless they are made of cotton.

    Tools Ensure that all tools which come into contact with static-sensitivecomponents are at the same voltage level as the conducting work surfacesand floor mats. These tools include soldering irons, oscilloscopes, powersupplies, and metal parts of tools and fixtures that are used to hold,assemble, or test Printed Board Assemblies (PBA)Do not use rough cleaners or erasers to clean the gold-plated contactson PBAs

    Do not mark a PBA with lead pencil or any other writing instrument

    Do not use synthetic brushes to clean equipment and do not use drycleaning methods.

    Transportation and

    Storage

    Pack all electronic components and modules in containers used to transportand store static-sensitive components and use aluminum container tubesif possible. If not, insert the components terminations into electricallyconductive foam

    Before shipping a PBA, wrap it in a conducting synthetic bag or in aluminumfoil. Also pack the PBA in a polyethylene transport box

    Before shipping a PBA which has Metal Oxide Semiconductor (MOS)components, ensure that an appropriate warning symbol is displayed onthe package

    Store spare PBAs in their appropriate polyethylene boxes. Keep the boxesclosed except when access to their contents is required

    Do not store PBAs in an area where the air is polluted with smoke, dust,dangerous gases, or other airborne particles that may cause damage

    Do not stack PBAs side-by-side or on top of each other with the boardsurfaces or components in contact with one another

    Before cleaning a PBA, remove or disconnect the damage protection, suchas protective foam, to allow the PBA to be cleaned thoroughly. Replace thedamage protection upon completion of the task.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 29 / 40

  • 2 General Information

    Components and PBAs Components and PBAs not in protective containers, must only be handledby trained personnel in static-controlled work areas

    Before removing a PBA from an equipment rack, discharge any static bytouching the metal frame of the rack with your hand

    Always handle a PBA by the edges

    Do not handle or carry a PBA by any mounted components

    Do not handle a PBA by the gold-plated contact terminals and do not applydirect pressure to the components

    Do not touch PBA connection pins or conductor paths

    Do not touch PBAs with wet hands

    Place PBAs that have been removed during maintenance with the solderedside down on a conductive surface

    Do not scratch or rub the soldered side of a PBA with a sharp or rough objectDo not repair PBAs in the switch room

    Do not handle components and assemblies by their leads

    Do not use excessive force when inserting connection boards.

    30 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 2 General Information

    2.3 Fill In a CCLFor all installation procedures a Generic CCL is used.Each commissioning procedure has its own CCL, identical in structure to theinstallation CCL, differing in task description.Filling in an installation and commissioning CCL is almost the same. Thedifferences will be described in this section.

    Figure 2: Explanation for Filling In a CCL

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 31 / 40

  • 2 General Information

    Nr. Explanations

    0 Title is Generic CCL for Installation or Procedure name for commissioning

    1 Name of the customer / operator

    2 ALCATEL market reference

    3 Type of equipment: A9120 BSC, G2 TC, BTS Indoor, BTS AC Indoor, BTS FV AA Outdoor,BTS FV BA Outdoor, BTS Evolution DC Indoor, BTS Evolution AC Indoor, BTS EvolutionOutdoor...

    4* Factory serial number S/N BSxxxxyyyyy where xxxx is the year and week in 2+2 digits andyyyyy can be digits and letters. The factory serial number is written on the big label with CEmarking.

    5* Rack serial number BSxxxxyyyyy or EKxxxxyyyyy where xxxx is the year and week in 2+2digits and yyyyy can be only digits. The rack serial number is written on a little label justbeside an other little label with MNEMONIC and ANV code (3BK zzzz zzzzz).

    6 Left empty for TC; for BSC number of racks; for BTSs, shows the number of sectors multipliedby number of TREs/sector. Example: 3x4, 2x6, 1x8.

    7 Site name.

    8 Address of the site, as detailed as possible.

    9 Documents used for installation and commissioning: ITL, IO, General Wiring Handbook(only for installation), Methods Handbook (only for commissioning), CEL, SPP__ (to fill in thespecific SPP number of procedure), tools catalogue... If other unlisted documents are used,write the title in the other document row. Fill in the edition number of the document used.

    10 Name and signature of concerned people.

    11 Start date, end date, and time spent on site in hours.

    Figure 3: Explanation for Recording the Results

    32 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 2 General Information

    12 List of tasks to be performed; for commissioning data boxes may appear, fill in with themeasured data.

    13 Check only one of the three boxes: Yes, No, Not Applicable (N.A.).14 Write the number of resolved (a.r.) or not resolved (a.n.r.) anomalies related to the task. The

    detailed description is entered in Table 2.

    Figure 4: Explanation for Describing Anomalies

    15 Write the Chapter title and number in which the task that generated the anomaly occurred.

    16 Write the detailed description of the anomaly. Be clear and precise, give figures and facts.

    17 For each anomaly a Fault Report must be written, give the number of the fault report so itcan be traced.

    18 If the anomaly is solved, write the detailed solution description.

    19 Give the date when the anomaly occurred.

    20 Give the date when the anomaly was solved.

    21 Give the name and identification data (company, phone number,...) of the person who solvedthe anomaly.

    * Examples for finding the location of labels with factory and rack serial numbers.

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 33 / 40

  • 2 General Information

    For A9120 BSC The information is stuck on the right side of the air baffle.

    Figure 5: Label Location for A9120 BSC

    34 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 2 General Information

    For G2 TC The information is stuck on the middle of the right panel.

    Figure 6: Label Location for G2 TC

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 35 / 40

  • 2 General Information

    For A9125 TC The information is stuck on the rear bottom side of the rack.

    Figure 7: Label Location for A9125 TC

    36 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 2 General Information

    For A9135 MFS The information is stuck on the bottom left corner, on the rack backside.

    Figure 8: Label Location for A9135 MFS

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 37 / 40

  • 2 General Information

    For A9130 BSC

    Evolution and A9130

    MFS Evolution

    The information is stuck the door on the right bottom side.

    Figure 9: Label Location for A9130 BSC Evolution and A9130 MFS Evolution

    38 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01

  • 2 General Information

    For Evolium Indoor BTS The information is stuck on the top left corner.

    Figure 10: Label Location for Evolium Indoor BTS

    3BK 17422 0002 PCZZA Ed.20P01 IN PREPARATION 39 / 40

  • 2 General Information

    For Evolium Outdoor

    BTS

    The information is stuck inside the left cabinet.

    Figure 11: Label Location for Evolium Outdoor BTS

    40 / 40 IN PREPARATION 3BK 17422 0002 PCZZA Ed.20P01