2/24/2020 1 Backflow Alert on Smart Meter! Now what to do Presented by: Gary McLaren - HydroCorp ASSE Certified Cross-Connection Program Administrator ASSE Certified Cross-Connection Surveyor Backflow Alert on Smart Meter! Now what to do Presented by: Gary McLaren - HydroCorp ASSE Certified Cross-Connection Program Administrator ASSE Certified Cross-Connection Surveyor But you Guy’s can call me.. the Backflow Nerd! Presented by: Gary McLaren ASSE Certified Cross Connection Program Administrator ASSE Certified Surveyor Weekend Plan: Should have stayed in FL”

Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

1

Backflow Alert on Smart Meter!Now what to do

Presented by:Gary McLaren - HydroCorp

ASSE Certified Cross-Connection Program Administrator

ASSE Certified Cross-Connection Surveyor

Backflow Alert on Smart Meter!Now what to do

Presented by:Gary McLaren - HydroCorp

ASSE Certified Cross-Connection Program Administrator

ASSE Certified Cross-Connection Surveyor

But you Guy’s can call me..

the Backflow Nerd!Presented by:Gary McLaren

ASSE Certified Cross Connection Program Administrator

ASSE Certified Surveyor

Weekend Plan:

“Should have stayed in FL”

Page 2: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

2

QTY of Cross-Connections Found

10/20/2018 9

3 Key Points of this Session

10/20/2018 11

• Common Backflow Hazards

• Smart Meter Alert! Now What?

• Meter Detected Backflow Case Study –

Water Research Foundation

The Bigger Picture

10/20/2018 12

Page 3: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

3

Backflow; Inherent Problem

10/20/2018 13

The Perfect Storm

10/20/2018 14

The Reverse Flow Data is There…

10/20/2018 15

The Perfect Storm

10/20/2018 16

Back Pressure:

10/20/2018 17

Back Siphonage:

10/20/2018 18

Page 4: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

4

What Exactly

is a Cross

Connection?

Most cross-connectionhazards are found downstream of a

meter/service connection(Internal Plumbing…)

Page 5: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

5

Does one Backflow

Preventer cover

everything?

Answer: NO

Containment Approach

(Backflow Preventer at meter)

27

Meter/Service Connection

Backflow Preventer downstream of Meter

Protects public water supply from contamination from within facility

28

Protects public water supply from contamination from within facility

Toilets

Boilers Treated with Chemicals?Water Softener Drains

Proper Air Gap at Drain?

Lawn IrrigationBackflow Prevention?

Hose Bibbs

Process water

Secondary Supply

Fire

Sprinklers

Chemical mixers

(Backflow Prevention at points of use)

Isolation Approach How many Pipes?

Page 6: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

6

31

Isolation Approach Backflow Prevention at each point of use within facility

Backflow Alert? Now What!?

10/20/2018 32

10/20/2018 33

Facility/Service Connection Info?

10/20/2018 34

• Is the Facility High Hazard or Low Hazard?

• Is the Facility properly contained?

• Has the Facility ever been surveyed for CC?

• Is there a pattern in the Reverse Flow Alerts?

Alert Trigger Criteria?

10/20/2018 35

• Does the Water Purveyor have a CCC Plan?

• Identify what false alerts look like

• Determine Reverse Flow Alert Response Plan

• Set alert lower for Residential VS Comm/IND

Reverse Flow Alert Plan

10/20/2018 36

• Utilize Meter Flow Date in your CCC Program

• Identify high risk water customer facilities

• Budget for ongoing plan management/IT

• Who should be alerted?

Page 7: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

7

Early Warning Can Reduce Risk

10/20/2018 37

“..Alerts are a Hassle”

38

Backflow / Reverse Flow Alert!

10/20/2018 39 10/20/2018 40

41

Page 8: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

8

Gary McLaren - Brookfield, WI

Page 9: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

9

Common Hazards During Backflow An Inherent Problem…

PreSsure

51

Top 10 Cross-Connection Hazards *Found:

1. Missing Vacuum Breaker on Hose Bibb (5,557)

2. Missing Air Gaps on ice machines and water softener discharges (2,691)

3. Chemically Treated Boilers with no backflow preventer (2,008)

4. Incorrectly installed backflow preventers (1,625)

5. Soap dispenser mixers incorrectly connected to utility sinks (1,370)

6. Soda Fountain Carbonators with missing backflow prevention (1,292)

7. Residential style boilers with no backflow prevention (909)

8. Industrial use hose drops with wrong type of backflow prevention (811)

9. Various improper plumbing installations related to backflow hazards (737)

10.Toilet tanks with unapproved or incorrectly installed backflow prevention (581)

*Found during HydroCorp CCC Surveys of client public water systems 2016-2017

Drinking Water Fountain Contamination

Pink Colored Water…

53

Common Hazard:Process Use Systems – Boiler Systems – Chemically Treated and Non Chemical

43 54

Common Hazard:Air Gaps

Page 10: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

10

55

Common Hazard:Air Gaps

46 56

Common Hazard:Air Gaps

47

58

Common Hazard:Chemical Mixing Systems

48

59

Common Hazard:Chemical Mixing Systems

49 60

Common Hazard:Chemical Mixing Systems

• ASSE 1055B

50

Page 11: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

11

61

Common Hazard:Incorrectly Installed Backflow Preventers

• All Piping

Downstream must

be lower than the

backflow preventer

51 62

Common Hazard:Incorrectly Installed Backflow Preventers

52

63

Common Hazard:Incorrectly Installed Backflow Preventers

53 64

Common Hazard:Commercial Kitchens

54

65

Commercial Kitchen

66

Commercial Kitchen

Page 12: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

12

67

Common Hazard:Unprotected Bypass

63 68

Common Hazard:Unprotected Bypass

64

69

Common Hazard:Dead Legs/Unused piping

64

Backflow Alert on Smart Meter!Now what to do

Presented by:Gary McLaren - HydroCorp

ASSE Certified Cross-Connection Program Administrator

ASSE Certified Cross-Connection Surveyor

10/20/2018 72

Page 13: Backflow Alert on Smart Meter! - treeo.ufl.edu...Facility/Service Connection Info? 10/20/2018 34 •Is the Facility High Hazard or Low Hazard? •Is the Facility properly contained?

2/24/2020

13

3 Key Points of this Session

10/20/2018 73

• Common Backflow Hazards

• Smart Meter Alert! Now What?

• Meter Detected Backflow Case Study –

Water Research Foundation

Thanks for attending!

Presented by:

Gary McLarenCross-Connection Control Programs

and Meter Install Services

Text/Call Anytime – 262.951.0059Florida – Coastal States - Midwest

HydroCorpinc.com