BASE LINK TOILET SUITE
CLEANING RECOMMENDATIONSWe recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty - refer to Warranty Page for full Terms and Conditions.
To see the complete Base range go to www.reece.com.au/bathrooms
SPECIFICATIONSRecommended use Domestic, hotel, commercial
Material Vitreous china with plastic cistern
Water inlet Let or right bottom inlet
Pan Trap S or P trap available
Colour Availability White
Capacity 4.5/3L, adjustable to 6/3L or 9/4.5L
Standards AS 1172
WELS 4 stars
4.5/3 litres per flush, average 3.5 litres per flush
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.
Tech Page Version 2
185
418
165 recommended(150 min. – 250 max.)
375
20
Bot
tom
Inle
t 430
Ultr
a lo
w le
vel
775
appr
ox. t
o fix
ing
cent
res
for
Ultr
a lo
w le
vel
850
appr
ox. f
or U
ltra
low
leve
l
210Inlet
365Fixing centre
365
167
163
440
650
min
. – 7
50 m
ax.
395
The more
4.5 L per full flush / 3 L per half flush
In accordance with AS/NZS 6400
Licence No. 0001Caroma Industries Limited
stars the more water efficient
WATER RATING www.waterrating.gov.au
3.5 litresaverage flush
page 1 of 3
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
VITREOUS CHINA
PAN FIXING PROCEDURERough-in ProcedureThe soil pipe and pan collar should be accurately fixed into position, as detailed in Figure 1 and Figure 2.
Pan Bedding:1- Remove an area of tiles which are within the internal area
covered by the foot of the pan to expose the subfloor toprovide a bondage key for the bedding mixture.
2- Ensure that bedding area is clean and free of building material.
3- Prepare bedding sand cement mixture 3:1 to depth of 60mmas detailed in Figure 1 or Figure 2.
NOTE: Do not fill the foot of the pan with bedding mix or include lime or fast drying cement in the mix, these may cause cracking in the foot of the pan.
4- Position pan and connect with pan connector then level paninto bedding mixture, so that the back of the foot of the panis approximately 10mm above the finished floor as detailedin Figure 3. It is recommended that wedges are used tosupport the foot of the pan during the positioning.
Bed
ded
pos
ition
10m
m
Level pan whenbedding
Finishedfloor level
FinishedWall
165
Fig. 2
Fig. 3
Fig. 1
Bedding mix height 60mm
'P' trap installation FinishedWall
Standard PanConnector
185
Standardpanconnector
Relieve bedaroundpan connector
Pan foot level
Finished Wall
Bed
din
g he
ight
60m
m
165 Recommendedset out
60
'S' trap installation
IMPORTANT: ALL DIMENSIONS ARE TO THE UNDERSIDEFOOT LEVEL OF THE PAN. IT IS IMPORTANT TO MAKE AHEIGHT ALLOWANCE FOR BEDDING.
120Recommended
set-out
SCREW FIXING:1- Position pan onto pan connector. Adjust pan position if
necessary and mark location of pan fixing holes on the floor.Remove the pan.
2- Drill holes in the marked positions on the floor. The holediameter is dependent on the type of fixing system and floor finish.
IMPORTANT: DO NOT USE THE PAN SCREW HOLES AS A GUIDE FOR DRILLING AS THIS MAY CRACK THE PAN.
3- Ensure that the area around the floor is clean and free frombuilding material.
4- Run a bead of acetic cured silicone sealant at a height of 8mmapproximately fully around the foot of the pan which contacts thefloor. Use wedges around the foot base (if required) so that themaximum height of silicone sealant is not greater that 5mm oncompletion on bedding.
5- Connect pan to pan connector and fix to the floor with suitablecorrosion resistant screws. Level the pan with the acetic curedsilicone sealant to the finished floor. Remove any excesssealant.
Pan foot level
BASE ADJUSTABLE TOILET SUITE (4*)
Disclaimer:Products in this speci�cation manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary speci�cations or delete models from their range without prior noti�cation. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.
The morestars the morewater e�cient
A joint government and industry program
litres per full �ush
litres per half �ush
4.533.5 litres per average �ush
For more information and to compareproducts, refer to:
www.waterrating.gov.au
When tested in accordance with Standard AS/NZS 6400
WATERRATING
Licence No. 0001
V C
O N L Y
TM
Certi
�edP
rodu
ct
AustralianStandard
WaterMarkAS 1172
Lic SMK1368/1WMKA1368/1
SAI Global
TM
®
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference
page 2 of 3
BASE LINK TOILET SUITE
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
10 mm
8 mm
3 mm
In masonry, drill 8mm diameter holes and insert the plugs provided. In timber, drill 3mm diameter pilot holes.Leave the screws protruding by 10mm.
Flush the water supply line.
Make sure that the strainer is in place. Then fit the water supply pipe using approved fittings.
Turn on the water. Operate the cistern and check for leaks.
Carefully refit the lid.Actuate the Inlet valve at least once to purge any trapped air in the valve.Adjust the water level to the WL2 mark.
20 mm
53 mm
Kee seal
Cut the flushpipe to dimensions shown. Lubricate the kee seal with soap and water and fit the pipe.
Lower the cistern onto the pipe and hook it over the mounting screws.
Nip up the mounting screws.Hand tighten the nut.
When installing low level use L-shaped pipe only. For mid level fit the seal and lubricate it with soap and water. Push firmly into the shorter leg of the flush pipe.
168mm
240 mm
Correct fitting of SealNOTE: Do Not use extension horizontally
Check that the pan is installed within dimensional tolerances. Mark out the fixing holes for the cistern on the wall making sure they are level.
400 mm Reference
105 mm
50 - 260 mm to suit tiling
Top of Pan
775 mm Fixing Holes (Mid Level)
365 mm Fixing Holes
190 - 330 mm
165 mm - Recommended
445 mm Fixing Holes (Low Level)
Adjustment Screw
BASE ADJUSTABLE TOILET SUITE (4*)
Disclaimer:
Products in this specification manual must by regulation be installed by licensed and registered trade people.
The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification.
Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.
The morestars the morewater efficient
A joint government and industry program
litres per full flush
litres per half flush
4.533.5 litres per average flush
For more information and to compareproducts, refer to:
www.waterrating.gov.au
When tested in accordance with Standard AS/NZS 6400
WATERRATING
Licence No. 0001
VC
ONLY
TM
Certi
fied P
rodu
ct
AustralianStandard
WaterMarkAS 1172
Lic SMK1368/1WMKA1368/1
SAI Global
TM
®
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference
page 3 of 3
BASE LINK TOILET SUITE