BASE LINK TOILET SUITE CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty - refer to Warranty Page for full Terms and Conditions. To see the complete Base range go to www.reece.com.au/bathrooms SPECIFICATIONS Recommended use Domestic, hotel, commercial Material Vitreous china with plastic cistern Water inlet Let or right bottom inlet Pan Trap S or P trap available Colour Availability White Capacity 4.5/3L, adjustable to 6/3L or 9/4.5L Standards AS 1172 WELS 4 stars 4.5/3 litres per flush, average 3.5 litres per flush Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version 2 185 418 165 recommended (150 min. – 250 max.) 375 20 Bottom Inlet 430 Ultra low level 775 approx. to fixing centres for Ultra low level 850 approx. for Ultra low level 210 Inlet 365 Fixing centre 365 167 163 440 650 min. – 750 max. 395 The more 4.5 L per full flush / 3 L per half flush In accordance with AS/NZS 6400 Licence No. 0001 Caroma Industries Limited stars the more water efficient WATER RATING www.waterrating.gov.au 3.5 litres average flush page 1 of 3

BASE LINK TOILET SUITE...BASE LINK TOILET SUITE CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BASE LINK TOILET SUITE...BASE LINK TOILET SUITE CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive

BASE LINK TOILET SUITE

CLEANING RECOMMENDATIONSWe recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty - refer to Warranty Page for full Terms and Conditions.

To see the complete Base range go to www.reece.com.au/bathrooms

SPECIFICATIONSRecommended use Domestic, hotel, commercial

Material Vitreous china with plastic cistern

Water inlet Let or right bottom inlet

Pan Trap S or P trap available

Colour Availability White

Capacity 4.5/3L, adjustable to 6/3L or 9/4.5L

Standards AS 1172

WELS 4 stars

4.5/3 litres per flush, average 3.5 litres per flush

Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

Tech Page Version 2

185

418

165 recommended(150 min. – 250 max.)

375

20

Bot

tom

Inle

t 430

Ultr

a lo

w le

vel

775

appr

ox. t

o fix

ing

cent

res

for

Ultr

a lo

w le

vel

850

appr

ox. f

or U

ltra

low

leve

l

210Inlet

365Fixing centre

365

167

163

440

650

min

. – 7

50 m

ax.

395

The more

4.5 L per full flush / 3 L per half flush

In accordance with AS/NZS 6400

Licence No. 0001Caroma Industries Limited

stars the more water efficient

WATER RATING www.waterrating.gov.au

3.5 litresaverage flush

page 1 of 3

Page 2: BASE LINK TOILET SUITE...BASE LINK TOILET SUITE CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive

INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS

VITREOUS CHINA

PAN FIXING PROCEDURERough-in ProcedureThe soil pipe and pan collar should be accurately fixed into position, as detailed in Figure 1 and Figure 2.

Pan Bedding:1- Remove an area of tiles which are within the internal area

covered by the foot of the pan to expose the subfloor toprovide a bondage key for the bedding mixture.

2- Ensure that bedding area is clean and free of building material.

3- Prepare bedding sand cement mixture 3:1 to depth of 60mmas detailed in Figure 1 or Figure 2.

NOTE: Do not fill the foot of the pan with bedding mix or include lime or fast drying cement in the mix, these may cause cracking in the foot of the pan.

4- Position pan and connect with pan connector then level paninto bedding mixture, so that the back of the foot of the panis approximately 10mm above the finished floor as detailedin Figure 3. It is recommended that wedges are used tosupport the foot of the pan during the positioning.

Bed

ded

pos

ition

10m

m

Level pan whenbedding

Finishedfloor level

FinishedWall

165

Fig. 2

Fig. 3

Fig. 1

Bedding mix height 60mm

'P' trap installation FinishedWall

Standard PanConnector

185

Standardpanconnector

Relieve bedaroundpan connector

Pan foot level

Finished Wall

Bed

din

g he

ight

60m

m

165 Recommendedset out

60

'S' trap installation

IMPORTANT: ALL DIMENSIONS ARE TO THE UNDERSIDEFOOT LEVEL OF THE PAN. IT IS IMPORTANT TO MAKE AHEIGHT ALLOWANCE FOR BEDDING.

120Recommended

set-out

SCREW FIXING:1- Position pan onto pan connector. Adjust pan position if

necessary and mark location of pan fixing holes on the floor.Remove the pan.

2- Drill holes in the marked positions on the floor. The holediameter is dependent on the type of fixing system and floor finish.

IMPORTANT: DO NOT USE THE PAN SCREW HOLES AS A GUIDE FOR DRILLING AS THIS MAY CRACK THE PAN.

3- Ensure that the area around the floor is clean and free frombuilding material.

4- Run a bead of acetic cured silicone sealant at a height of 8mmapproximately fully around the foot of the pan which contacts thefloor. Use wedges around the foot base (if required) so that themaximum height of silicone sealant is not greater that 5mm oncompletion on bedding.

5- Connect pan to pan connector and fix to the floor with suitablecorrosion resistant screws. Level the pan with the acetic curedsilicone sealant to the finished floor. Remove any excesssealant.

Pan foot level

BASE ADJUSTABLE TOILET SUITE (4*)

Disclaimer:Products in this speci�cation manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary speci�cations or delete models from their range without prior noti�cation. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

The morestars the morewater e�cient

A joint government and industry program

litres per full �ush

litres per half �ush

4.533.5 litres per average �ush

For more information and to compareproducts, refer to:

www.waterrating.gov.au

When tested in accordance with Standard AS/NZS 6400

WATERRATING

Licence No. 0001

V C

O N L Y

TM

Certi

�edP

rodu

ct

AustralianStandard

WaterMarkAS 1172

Lic SMK1368/1WMKA1368/1

SAI Global

TM

®

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

page 2 of 3

BASE LINK TOILET SUITE

Page 3: BASE LINK TOILET SUITE...BASE LINK TOILET SUITE CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive

INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS

10 mm

8 mm

3 mm

In masonry, drill 8mm diameter holes and insert the plugs provided. In timber, drill 3mm diameter pilot holes.Leave the screws protruding by 10mm.

Flush the water supply line.

Make sure that the strainer is in place. Then fit the water supply pipe using approved fittings.

Turn on the water. Operate the cistern and check for leaks.

Carefully refit the lid.Actuate the Inlet valve at least once to purge any trapped air in the valve.Adjust the water level to the WL2 mark.

20 mm

53 mm

Kee seal

Cut the flushpipe to dimensions shown. Lubricate the kee seal with soap and water and fit the pipe.

Lower the cistern onto the pipe and hook it over the mounting screws.

Nip up the mounting screws.Hand tighten the nut.

When installing low level use L-shaped pipe only. For mid level fit the seal and lubricate it with soap and water. Push firmly into the shorter leg of the flush pipe.

168mm

240 mm

Correct fitting of SealNOTE: Do Not use extension horizontally

Check that the pan is installed within dimensional tolerances. Mark out the fixing holes for the cistern on the wall making sure they are level.

400 mm Reference

105 mm

50 - 260 mm to suit tiling

Top of Pan

775 mm Fixing Holes (Mid Level)

365 mm Fixing Holes

190 - 330 mm

165 mm - Recommended

445 mm Fixing Holes (Low Level)

Adjustment Screw

BASE ADJUSTABLE TOILET SUITE (4*)

Disclaimer:

Products in this specification manual must by regulation be installed by licensed and registered trade people.

The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification.

Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

The morestars the morewater efficient

A joint government and industry program

litres per full flush

litres per half flush

4.533.5 litres per average flush

For more information and to compareproducts, refer to:

www.waterrating.gov.au

When tested in accordance with Standard AS/NZS 6400

WATERRATING

Licence No. 0001

VC

ONLY

TM

Certi

fied P

rodu

ct

AustralianStandard

WaterMarkAS 1172

Lic SMK1368/1WMKA1368/1

SAI Global

TM

®

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

page 3 of 3