19
BBG BETA BURNER GAS SERIES NATURAL GAS OPERATION MODEL NUMBER SPECIFICATIONS _ _04 _ _06 _ _08 _ _10 _ _12 _114 _118 _124 Max. Input @ 10% Excess Air (MMBtu/hr) 2.2 4.9 8.8 13.6 19.8 27 44.5 87 Max. Air Flow @ 8 osig (scfh) 22,800 50,800 91,300 141,000 205,000 280,000 461,000 903,000 Max. Excess Air (%) 400 260 800 275 320 400 650 600 H I G H F I R E Flame Length @ Max. Input (ft.) 4.5 5.8 7 9.3 10.1 10.8 15.5 23.6 Max. Input @ 10% Excess Air (MMBtu/hr) 0.32 0.69 1.3 2.0 2.9 3.9 6.5 12.7 Air Flow @ 0.17 osig (scfh) 3,320 7,140 13,300 20,600 29,900 40,800 67,200 132,000 L O W F I R E Max. Excess Air (%) 100 80 240 100 120 150 280 100 NOTES: 1. Capacities based on natural gas with HHV of 1034 Btu/ft 3 , 0.59 S.G., and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 60°F @ sea level. 3. Static air pressures measured at the burner air inlet pressure tap. 4. Flame lengths measured from the end of converging tile; for a diverging tile (available for _ _06 through _118), add 18% to the flame length. 5. To determine flame lengths at different excess air values, use the following equation: 6. All data based on industry standard air and gas piping practices. 7. Burners can be operated up to a static air pressure of 12 osig; consult Hauck. In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. CAPACITIES BBG-2 (Metric Capacities on Reverse Side.) HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 8/05 www.hauckburner.com Fax: 717-273-9882

BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

NATURAL GAS OPERATION

MODEL NUMBER

SPECIFICATIONS _ _04 _ _06 _ _08 _ _10 _ _12 _114 _118 _124

Max. Input @ 10% Excess Air (MMBtu/hr) 2.2 4.9 8.8 13.6 19.8 27 44.5 87

Max. Air Flow @ 8 osig (scfh) 22,800 50,800 91,300 141,000 205,000 280,000 461,000 903,000

Max. Excess Air (%) 400 260 800 275 320 400 650 600

H I G H F I R E Flame Length @ Max. Input (ft.) 4.5 5.8 7 9.3 10.1 10.8 15.5 23.6

Max. Input @ 10% Excess Air (MMBtu/hr) 0.32 0.69 1.3 2.0 2.9 3.9 6.5 12.7

Air Flow @ 0.17 osig (scfh) 3,320 7,140 13,300 20,600 29,900 40,800 67,200 132,000

L O W F I R E

Max. Excess Air (%) 100 80 240 100 120 150 280 100

NOTES: 1. Capacities based on natural gas with HHV of 1034 Btu/ft3, 0.59 S.G., and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 60°F @ sea level. 3. Static air pressures measured at the burner air inlet pressure tap. 4. Flame lengths measured from the end of converging tile; for a diverging tile (available for _ _06 through _118), add 18% to the flame length. 5. To determine flame lengths at different excess air values, use the following equation: 6. All data based on industry standard air and gas piping practices. 7. Burners can be operated up to a static air pressure of 12 osig; consult Hauck. In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

CAPACITIES

BBG-2

(Metric Capacities on Reverse Side.)

HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 8/05 www.hauckburner.com Fax: 717-273-9882

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 2: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

NATURAL GAS OPERATION

MODEL NUMBER

SPECIFICATIONS _ _04 _ _06 _ _08 _ _10 _ _12 _114 _118 _124

Max. Input @ 10% Excess Air (kW) 582 1,300 2,860 3,600 5,240 7,140 11,800 23,000

Max. Air Flow @ 3450 Pa (nm3/hr) 611 1,360 2,450 3,780 5,490 7,500 12,300 24,200

Max. Excess Air (%) 400 260 800 275 320 400 650 600

H I G H

F I R E Flame Length @ Max. Input (m) 1.4 1.8 2.1 2.8 3.1 3.3 4.7 7.2

Max. Input @ 10% Excess Air (kW) 85 183 344 529 767 1,030 1,720 3,360

Air Flow @ 75 Pa (nm3/hr) 89 191 356 552 801 1,090 1,800 3,540

L O W

F I R E

Max. Excess Air (%) 100 80 240 100 120 150 280 100

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3 0.59 S.G., and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level. 3. Static air pressures measured at the burner air inlet pressure tap. 4. Flame lengths measured from the end of converging tile; for a diverging tile (available for _ _06 through _118), add 18% to the flame length. 5. To determine flame lengths at different excess air values, use the following equation: 6. All data based on industry standard air and gas piping practices. 7. Burners can be operated up to a static air pressure of 5170 Pa; consult Hauck. In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC CAPACITIES

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 3: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER – PILOT IGNITION BBG _104

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

DIMENSIONS

(See Reverse Side For Metric Dimensions)

X69

05

(NO

T T

O S

CA

LE)

HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 8/05 www.hauckburner.com Fax: 717-273-9882

BBG-3

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 4: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER – PILOT IGNITION BBG _104

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DIMENSIONS

X69

05 M

ET

RIC

(N

OT

TO

SC

ALE

)

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 5: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER – PILOT IGNITION BBG _106 THROUGH _118

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DIMENSIONS

Y68

71 M

ET

RIC

(N

OT

TO

SC

ALE

)

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 6: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNERS – PILOT IGNITION BBG _124

I n accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DIMENSIONS

Y68

72 M

ET

RIC

(N

OT

TO

SC

ALE

)

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 7: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER – DIRECT SPARK IGNITION BBG _204

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DIMENSIONS

X78

00 M

ET

RIC

(N

OT

TO

SC

ALE

)

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 8: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER – DIRECT SPARK IGNITION BBG _206 - _212

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DIMENSIONS

Y78

01 M

ET

RIC

(N

OT

TO

SC

ALE

)

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 9: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

BURNER MODEL BBG_ _04

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

SUPPLEMENTAL DATA

STATIC AIR PRESSURE AT BURNER INLET TAP

0.17 OSIG 1 OSIG 2 OSIG 4 OSIG 8 OSIG 12 OSIG

Burner Input @ 10% Excess Air (MMBtu/hr) 0.32 0.78 1.1 1.6 2.2 2.7

Max. Air Flow (Not Firing) (scfh) ---

Max. Air Flow (scfh) 3,320 8,060 11,400 16,100 22,800 27,900

Gas Inlet Pressure ("wc) --- --- --- --- 0.4 ---

Max. Excess Air (%) 100 200 300 400 400 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (ft) 2.7 2.7 2.7 3.2 4.5 5.5

Flame Diameter (ft) 0.9 1.0 1.0 1.0 1.5 1.5

NOTES: 1. Capacities based on natural gas with HHV of 1034 Btu/ft3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 60°F @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; diverging tile not available. 4. All data based on industry standard air and gas piping practices.

BBG-4

(See Reverse Side for Metric Data)

HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 8/05 www.hauckburner.com Fax: 717-273-9882

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 10: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER

GAS SERIES

BURNER MODEL BBG_ _04

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DATA

STATIC AIR PRESSURE AT BURNER INLET TAP

75 Pa 430 Pa 860 Pa 1,725 Pa 3,450 Pa 5,170 Pa

Burner Input @ 10% Excess Air (kW) 85 206 291 423 582 714

Max. Air Flow (Not Firing) (nm3/hr) ---

Max. Air Flow (nm3/hr) 89 216 305 431 611 747

Gas Inlet Pressure (Pa) --- --- --- --- -100 ---

Max. Excess Air (%) 100 200 300 400 400 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (m) 0.8 0.8 0.8 1.0 1.4 1.7

Flame Diameter (m) 0.3 0.3 0.3 0.3 0.5 0.5

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; diverging tile not available. 4. All data based on industry standard air and gas piping practices.

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 11: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

BURNER MODEL BBG_ _06

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DATA

STATIC AIR PRESSURE AT BURNER INLET TAP 75 Pa 430 Pa 860 Pa 1,725 Pa 3,450 Pa 5,170 Pa

Burner Input @ 10% Excess Air (kW) 183 450 661 926 1,300 1,590

Max. Air Flow (Not Firing) (nm3/hr) ---

Max. Air Flow (nm3/hr) 191 482 680 962 1,360 1,670

Gas Inlet Pressure (Pa) --- --- --- --- 1,240 ---

Max. Excess Air (%) 80 150 240 180 260 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (m) 0.7 0.9 1.1 1.4 1.8 1.8

Flame Diameter (m) 0.5 0.5 0.5 0.5 0.5 0.5

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; for diverging tile add 18% to the flame length. 4. All data based on industry standard air and gas piping practices.

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 12: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

BURNER MODEL BBG_ _08

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DATA

STATIC AIR PRESSURE AT BURNER INLET TAP

75 Pa 430 Pa 860 Pa 1,725 Pa 3,450 Pa 5,170 Pa

Burner Input @ 10% Excess Air (kW) 344 820 1,160 1,640 2,330 2,860

Max. Air Flow (Not Firing) (nm3/hr) ---

Max. Air Flow (nm3/hr) 356 865 1,220 1,730 2,450 3,000

Gas Inlet Pressure (Pa) --- --- --- --- 1,690 ---

Max. Excess Air (%) 240 425 425 500 800 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (m) 1.2 1.6 1.9 2.0 2.1 ---

Flame Diameter (m) 0.6 0.8 0.8 0.8 0.9 ---

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; for diverging tile add 18% to the flame length. 4. All data based on industry standard air and gas piping practices.

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 13: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

BURNER MODEL BBG_ _10

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DATA

STATIC AIR PRESSURE AT BURNER INLET TAP

75 Pa 430 Pa 860 Pa 1,725 Pa 3,450 Pa 5,170 Pa

Burner Input @ 10% Excess Air (kW) 529 1,270 1,800 2,540 3,600 4,420

Max. Air Flow (Not Firing) (nm3/hr) ---

Max. Air Flow (nm3/hr) 552 1,340 1,890 2,670 3,780 4,630

Gas Inlet Pressure (Pa) --- --- --- --- 2,070 ---

Max. Excess Air (%) 100 250 320 300 275 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (m) 1.5 2.8 2.8 2.8 2.8 ---

Flame Diameter (m) 1.0 1.3 1.4 1.3 1.3 ---

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; for diverging tile add 18% to the flame length. 4. All data based on industry standard air and gas piping practices.

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 14: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

BURNER MODEL BBG_ _12

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DATA

STATIC AIR PRESSURE AT BURNER INLET TAP

75 Pa 430 Pa 860 Pa 1,725 Pa 3,450 Pa 5,170 Pa

Burner Input @ 10% Excess Air (kW) 767 1,850 2,620 3,700 5,240 6,400

Max. Air Flow (Not Firing) (nm3/hr) ---

Max. Air Flow (nm3/hr) 801 1,940 2,760 3,880 5,490 6,720

Gas Inlet Pressure (Pa) --- --- --- --- 746 ---

Max. Excess Air (%) 120 250 280 300 320 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (m) 0.9 1.9 2.1 2.3 3.0 ---

Flame Diameter (m) 0.8 0.8 0.8 0.8 1.3 ---

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; for diverging tile add 18% to the flame length. 4. All data based on industry standard air and gas piping practices.

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 15: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

BURNER MODEL BBG_114

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DATA

STATIC AIR PRESSURE AT BURNER INLET TAP

75 Pa 430 Pa 860 Pa 1,725 Pa 3,450 Pa 5,170 Pa

Burner Input @ 10% Excess Air (kW) 1,030 2,540 3,570 5,050 7,140 8,750

Max. Air Flow (Not Firing) (nm3/hr) ---

Max. Air Flow (nm3/hr) 1,090 2,650 3,750 5,300 7,500 9,190

Gas Inlet Pressure (Pa) --- --- --- --- 149 ---

Max. Excess Air (%) 150 200 250 285 400 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (m) 1.2 1.6 2.3 2.8 3.4 ---

Flame Diameter (m) 0.5 0.6 0.8 0.8 1.0 ---

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; for diverging tile add 18% to the flame length. 4. All data based on industry standard air and gas piping practices.

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 16: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

BURNER MODEL BBG_118

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DATA

STATIC AIR PRESSURE AT BURNER INLET TAP

75 Pa 430 Pa 860 Pa 1,725 Pa 3,450 Pa 5,170 Pa

Burner Input @ 10% Excess Air (kW) 1,720 4,150 5,900 8,330 11,800 14,400

Max. Air Flow (Not Firing) (nm3/hr) ---

Max. Air Flow (nm3/hr) 1,800 4,370 6,190 8,730 12,400 15,100

Gas Inlet Pressure (Pa) --- --- --- --- 1,620 ---

Max. Excess Air (%) 280 280 300 480 650 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (m) 0.9 3.5 4.0 4.1 4.7 ---

Flame Diameter (m) 0.5 0.8 0.8 0.9 1.3 ---

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; for diverging tile add 18% to the flame length. 4. All data based on industry standard air and gas piping practices.

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 17: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES

BURNER MODEL BBG_124

NATURAL GAS OPERATION

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

METRIC DATA

STATIC AIR PRESSURE AT BURNER INLET TAP

75 Pa 430 Pa 860 Pa 1,725 Pa 3,450 Pa 5,170 Pa

Burner Input @ 10% Excess Air (kW) 3,360 8,150 11,500 16,300 23,000 28,000

Max. Air Flow (Not Firing) (nm3/hr) ---

Max. Air Flow (nm3/hr) 3,540 8,550 12,100 17,100 24,200 29,700

Gas Inlet Pressure (Pa) --- --- --- --- -249 ---

Max. Excess Air (%) 100 150 250 400 600 ---

Max. Excess Fuel (%) --- --- --- --- --- ---

Flame Length (m) 1.5 2.2 4.4 6.1 7.3 ---

Flame Diameter (m) 0.7 0.9 1.2 1.2 1.5 ---

NOTES: 1. Capacities based on natural gas with LHV of 36.74 MJ/nm3, 0.59 S.G. and a stoichiometric air/gas ratio of 9.74:1 with burner firing into chamber under no pressure. 2. Air and gas flows based on 0°C @ sea level; capacities for preheated air will differ from those shown. 3. Flame lengths measured from the end of converging tile; diverging tile not available. 4. All data based on industry standard air and gas piping practices.

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 18: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. BBG-4.8

SUPPLEMENTAL DATA

Y77

29

(NO

T T

O S

CA

LE)

CR

OS

S-C

ON

NE

CT

ED

RA

TIO

CO

NT

RO

L

GA

S W

/PIL

OT

IGN

ITIO

N

(OVER)

HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 8/05 www.hauckburner.com Fax: 717-273-9882

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com
Page 19: BBG BETA BURNER GAS SERIES - dinhhai.comdinhhai.com/storage/brand/eclipse/industrial-burner-gas/bbg/bbg.pdf · BBG BETA BURNER – PILOT IGNITION . BBG _104 . In accordance with Hauck’s

BBG BETA BURNER GAS SERIES In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

CR

OS

S-C

ON

NE

CT

ED

RA

TIO

CO

NT

RO

L

GA

S W

/DIR

EC

T S

PA

RK

IGN

ITIO

N

Y78

23

(NO

T T

O S

CA

LE)

SUPPLEMENTAL DATA

chi
Stamp
chi
Text Box
Cty TNHH THIẾT BỊ NHIỆT ĐÌNH HẢI VP: 189 Lý thường Kiệt, P.6, Q. Tân Bình, Tp HCM, VIỆT NAM Tel: (08) 3863 7722 # Fax: (08) 3865 1859 # URL: www.dinhhai.com