B_C10038.23757

Embed Size (px)

Citation preview

  • 7/24/2019 B_C10038.23757

    1/48

    l i n e a .

    S e l f - b e a r i n g c o v e r p l a t e s , a l l t h e b a s i c

    f u n c t i o n s a n d V i m a r q u a l i t y i n a f l e x i b l e ,

    r e l i a b l e a n d e c o n o m i c a l s e r i e s .

    T o s p r e a d p o s i t i v e e n e r g y i n s i d e t h e h o u s e .

    C A T A L O G U E E n g l i s h

    LINEA

  • 7/24/2019 B_C10038.23757

    2/48

  • 7/24/2019 B_C10038.23757

    3/48

    Positive energy. This is our philosophy. This

    is our story. A story which started over fifty years

    ago, on the first of May 1945, when Walter Viaro

    and Francesco Gusi decided to celebrate Labour

    Day in a special way, by setting up a new com-

    pany. And so the story of the Vimar V began. A

    story written with enthusiasm of people who take

    pride in what they do. Energy, positive vision, the

    drive to continually improve product quality, the

    ability to listen to commercial partners: these are

    the ingredients which have enabled the company

    to grow to its present size.

    VIMARS.p.A. Viale Vicenza, 14 - 36063 Marostica VI - Italy

    Tel +3 9. 04 24 .4 88 .6 00 - Fa x +3 9. 04 24 .4 88 .7 09

    ww w.v im ar. eu

  • 7/24/2019 B_C10038.23757

    4/48

    From Italy to the Far East.A consolidated production organisation in Italy. A sales and assembly network that comprises nine international units. Over 2500 employees who work in

    sinergy with professionals and operators in the local markets. Continually expanding sales, which this year touched 10,000,000 Euro. A product range with some three thousand codes,

    that is able to meet a vast array of standard and special requirements.

    Head office.Marostica, where Vimar was first established over fifty years ago, is

    the location of the new headquarters. It can be easily reached from the airports of

    Venice, Milan, Bologna, Verona and Trieste.

    ITALIA

    GRECIA

    ROMANIA

    VENEZUELA

    Production sites

    SIRIACHINA

    CHILE

  • 7/24/2019 B_C10038.23757

    5/48

  • 7/24/2019 B_C10038.23757

    6/48

    Quality system.Laboratory tests and inspections track the products from initial design through to final packaging, to guarantee certified quality.

  • 7/24/2019 B_C10038.23757

    7/48

    From design to distribution.Seventy thousand square metres of industrial area - the hub of our production energies. Research and development of new products. Design and

    product engineering using CAD systems. Working, pressing and moulding of plastics and metals. Fully computerised production, up until packaging and stock control. To answer to the

    needs of the markets in real time.

  • 7/24/2019 B_C10038.23757

    8/48

    From historic cafs to cruise ships. More than twenty-three million residential homes. And prestigious installations in Italy and around the world. From

    the historic Caff Pedrocchi in Padua, to the great Fincantieri cruise ships. From the Sangiorgi Theatre in Palermo, to the Malpensa 2000 international airport.

  • 7/24/2019 B_C10038.23757

    9/48

    From tourist resorts in the Aegean to the Ferretti Motoryachts. From the Venice Ghetto to French Television. From restoration of the national heritage,

    to major public works.

  • 7/24/2019 B_C10038.23757

    10/48

  • 7/24/2019 B_C10038.23757

    11/48

  • 7/24/2019 B_C10038.23757

    12/48

  • 7/24/2019 B_C10038.23757

    13/4811

    LINEA

    Index

    Equipments from page

    Types of mounting 38

    IP55 enclosures 41

    Accessories 36

    Switches 15

    Regulation and comfort 35

    Acoustic and optical signalling equipments 33

    Socket outlets and for signal reception 21

  • 7/24/2019 B_C10038.23757

    14/4812

    General features

    Wrap round structure for theusers complete protection.

    Protected terminals withdouble entry and patentedconfiguration.

    Balanced and noiselessrocking action.

  • 7/24/2019 B_C10038.23757

    15/48

    LINEA

    13

    General features

    Socket outlets with shuttered livesocket-contacts (degree of protection2.1 Italian standard CEI 23-16,increased protection CEI 23-50).

    Screw covering strips forself-bearing cover plates.

    Self-bearing cover plate with captivecross-slotted head screws zinc-platingtreatment and olive green passivation.

    Terminals placed on the backof the device. For 1 or 2 rigidor flexible cables, sized from0,75 mm2to 4 mm2.

  • 7/24/2019 B_C10038.23757

    16/4814

    Switches - TECHNICAL CHARACTERISTICS

    Devices

    10037

    For switch location in the dark:pilot lamp always lit

    For switch location in the dark:pilot lamp unlit when the controlled load is on

    Indication of the operation state of appliancesnot visible from the operating point:

    pilot lamp lit when the controlled load is on

    10038

    Wiring diagrams for luminous 1 P 1-way and 2-way switches with signalling unit 250 V~

    L1 2

    L

    N

    10037

    L1 2

    L

    N

    10037

    L1 2

    L

    N

    L1 2

    3

    L1 2

    3

    L

    N

    L1 2

    3

    L1 2

    3

    L

    N

    L1 2

    3

    L1 2

    3

    L

    N

    10038 10038

    ScopeSwitching on and off of ohm-inductive loads.

    lighting circuits for:

    - lighting fittings for use with incandescent lamps

    - lighting fittings for use with fluorescent lamps with or without

    power factor compensation

    dedicated circuits for:

    - motor driven appliances (fans, ventilators, canopy hoods, etc.)

    - switched socket outlets

    To locate the switches in case of reduced lighting or darkness,

    use luminous switches or switches with luminescent indicator.

    Conformity to StandardsLV Directive

    Standard EN 60669-1

    Technical specifications rated voltage: 250 V~

    rated current:

    - 10 A for push buttons

    - 10 AX or 16 AX for equipments that control circuits of

    fluorescent lamps with power factor compensation

    contact opening gap: > 3 mm

    insulation resistance: > 5 M tested with 500 V d.c.

    dielectric strength: > 2000 V~

    minimum breaking capacity:

    200 operations with 1,25 rated current, 275 V~ cos 0,3 and

    200 operations with 1,2 rated current, 250 V~, with load of

    tungsten filament lamp (except push buttons)

    minimum electrical life:

    - 40.000 operations with rated current, 250 V~, cos 0,6

    - 10.000 operations for 10 AX equipments (5.000 for 16 AX

    equipments) with rated current, 250 V~, with load of

    fluorescent lamps

    balanced and noiseless rocking action for 1-way, 2-way andreversing switches

    noiseless lever action with patented toggle joint for push buttons

  • 7/24/2019 B_C10038.23757

    17/4815

    LINEA

    Switches

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    Blank module and cable outlet10319 Blank module10314 Cable outlet with cord-grip

    1P 1-way switch 250 V~10000 1P 10 AX 1-way switch10001 1P 16 AX 1-way switch10037 1P 10 AX 1-way switch, luminous, for signalling unit. Supplied without signalling unit10016 2P 16 AX 1-way switch

    10319

    10016

    10314

    10037

    20

    23,5

    35,5

    1000010001

    23,5

    35,5

    20

    R. 3

    10

    1P 2-way switch 250 V~10004 1P 10 AX 2-way switch

    10005 1P 16 AX 2-way switch10038 1P 10 AX 2-way switch, luminous, for signalling unit. Supplied without signalling unit

    1000410005

    10038

    23,5

    35,5

    23,5

    35,5

  • 7/24/2019 B_C10038.23757

    18/4816

    Devices

    Switches - TECHNICAL CHARACTERISTICS

    Luminous switchesSignalling units

    Insertion of the signalling unit

    For switch location in the dark:pilot lamp always lit

    Wiring diagram for luminous 1P push button 10268with signalling unit 250 V~

    L1 2

    L

    N

    Article Type Supply voltage W max Colour

    10490 incandescent 12 V 0,5 white light

    10491 incandescent 24 V 1 white light

    10492 neon 110 V~ 0,5 red light

    10493 neon 250 V~ 0,5 red light

    10493.V fluorescent 250 V~ 0,5 green light

    10493.AZ fluorescent 250 V~ 0,5 blue light

    Range and technical specifications of signalling units

    A 1,5 F 400 V~ capacitor should be connected in parallel to neon or fluorescent signallingunits to avoid self-ignition in special circuits

  • 7/24/2019 B_C10038.23757

    19/4817

    LINEA

    Switches

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    Special 1P NO push button10270 1P NO 10 A 250 V~ cord-operated push button, with 1,5 m cord

    10270

    23,5

    37

    1P NO push button 250 V~10235 1P NO 10 A push button, general symbol10236 1P NO 10 A push button, bell symbol10268 1P NO 10 A push button, general symbol, luminous, for signalling unit. Supplied without signalling unit

    10268

    10235

    23,5

    35,5

    23,5

    35,5

    1P reversing switch 250 V~10013 1P 16 AX reversing switch

    10013

    37,5

    26

    10236

  • 7/24/2019 B_C10038.23757

    20/4818

    Devices

    Switches - TECHNICAL CHARACTERISTICS

    Article Type Supply voltage W Dimensions Colour

    07054 incandescent 12 V 3 7x29 mm white light

    07055 incandescent 24 V 3 7x29 mm white light

    Luminous name-plate push buttonTo be supplied through safety isolating transformer

    Microtube lamps

    Range and technical specifications for microtube lamps

    Cover plates dimensions:

    10725: 98x76 mm - flush depth: 33,5 mm

    10773: 120x76 mm - flush depth: 33,5 mm

    Switches with directional arrowsThese switches can be used for the direct control of motor

    driven loads, i.e. roller blinds, gates, etc.

    The push buttons may be associated with relays to control

    motor driven loads by pulses, i.e. roller blinds, gates, etc.10285 10280

    10773

    10773 - Microtube lamp fitting/replacement

  • 7/24/2019 B_C10038.23757

    21/4819

    LINEA

    Switches

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EUSide views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    Special 1P NO push button10773 1P NO 10 A 12-24 V (SELV) lightable name-plate push button for 12 or 24 V 3 W 7x31 mm lamp - provided with resin self-bearing cover

    plate, ivory, for 3-module mounting boxes and screw covering strips 10797.01

    10773

    Switches 250 V~ with directional arrows10285 1P 10 AX (3 terminals) 2-way switch, with directional arrows and central OFF position10280 1P 10 A (3 terminals) 2-way push button, with directional arrows and central OFF position

    1028010285

    43,5

    31,5

  • 7/24/2019 B_C10038.23757

    22/4820

    Devices

    Socket outlets - TECHNICAL CHARACTERISTICS

    Technical specifications of Italian standard socketoutlets rated voltage: 250 V~

    rated current: 10 A or 16 A

    shuttered live socket-contacts (degree of protection 2.1

    according to Italian standards CEI 23-16, increased

    protection according to Italian standard CEI 23-50)

    insulation resistance tested with 500 V d.c.: > 5 M;

    dielectric strength: 2000 V~

    breaking capacity: 50 operations (plug insertion and

    withdrawn) with 1,25 rated current 275 V~ cos 0,6

    electrical life: > 5000 (plug insertion and withdrawn) with rated

    current and voltage cos 0,6

    resilient wrap socket-contacts

    priority of connection on earthing socket-contacts

    ScopeSupply of electrical appliances, portable lighting fittings, etc.

    Conformity to StandardsItalian Standard CEI 23-50 (IEC 60884-1)

    5

    5 26

    4

    4

    19

    4

    4

    18

    5

    5

    5

    26

    4

    4

    4

    19

    Plugs standard VIMAR products

    2P 2.5 A

    2P+E 20 A 6

    6

    5

    26

    MILLE

    SUPERNOVA

    MILLE

    SUPERNOVA

    MILLE

    SUPERNOVA

    SUPERNOVA

    Matching plugs and socket outles standards

    P11

    10140

    01020 - 01020.B

    01040 - 01040.B

    01045 - 01045.B

    01026 - 01026.B

    01043 - 01043.B

    01048 - 01048.B

    P17/11

    10145

    01020 - 01020.B

    01040 - 01040.B

    01045 - 01045.B

    01021 - 01021.B

    01041 - 01041.B

    01046 - 01046.B

    01021 - 01021.B

    01041 - 01041.B

    01046 - 01046.B

    00200 - 00200.B 00200 - 00200.B

    ---

    ---

    ---

    00202 - 00202.B

    00207 - 00207.B

    00212 - 00212.B

    ---

    ---

    ---

    00201 - 00201.B

    00206 - 00206.B

    00211 - 00211.B

    00201 - 00201.B

    00206 - 00206.B

    00211 - 00211.B

    ---

    --- ---

    19

    26

    19

    2P 10 A

    2P 16 A

    2P+E 10 A

    2P+E 16 A

    S10

    S11

    SPA11

    S11

    S11

    SPA11

    S11

    S17

    SPA17

    S17

    S17

    SPA17

    S17

    S10

    S10

    Europlug

    S16

    Plugs and socket outlets - matching possibilities

  • 7/24/2019 B_C10038.23757

    23/4821

    LINEA

    *Only for Countries not members of the EUSide views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    Socket outlets

    Italian standard socket outlet 250 V~10140 2P+E 10 A SICURY socket outlet, Italian standard P1110145 2P+E 16 A Bpresa SICURY socket outlet, Italian standard P17/11

    10140

    24,5

    32,5

    10145

    24,5

    32,5

  • 7/24/2019 B_C10038.23757

    24/4822

    Devices

    Socket outlets - TECHNICAL CHARACTERISTICS

    5

    5 26

    4

    4

    19

    4

    4

    18

    5

    5

    5

    26

    4

    4

    4

    19

    Plugs standard VIMAR products

    2P 10 A

    2P 2.5 A

    2P 16 A

    2P+E 10 A

    2P+E 16 A

    MILLE

    SUPERNOVA

    MILLE

    SUPERNOVA

    MILLE

    SUPERNOVA

    SUPERNOVA

    Plugs and socket outlets matching possibilities

    01020 - 01020.B

    01045 - 01045.B

    01026 - 01026.B

    01048 - 01048.B

    01021 - 01021.B

    01046 - 01046.B

    00200 - 00200.B

    01020 - 01020.B

    01045 - 01045.B

    S10

    S10

    S10 00200 - 00200.B

    ---

    ---

    00202 - 00202.B

    00212 - 00212.B---

    00230 - 00230.B

    ---

    00201 - 00201.B

    00211 - 00211.B

    ---

    01021 - 01021.B

    01046 - 01046.B

    00201 - 00201.B

    00211 - 00211.B

    2P 16 A

    19

    4,8

    2P+E 16 A

    19

    4,8

    4,8

    4,8

    00231 - 00231.B

    00241 - 00241.B

    00230 - 00230.B

    00231 - 00231.B

    00241 - 00241.B

    P30

    19

    12,7SICUREZZA

    UNIVERSALE

    26

    19

    Europlugs

    S11

    S11

    S11

    S11

    S16

    German

    standard

    German

    standard

    German+ French

    standard

    German

    + French

    standard

    S17

    S17

    S17

    S17

    SICURY socket outlets, universal, other characteristics:

    - abbreviations I and D (Italian and German standards) and

    USA 2P (American standard) positioned next to the holes of

    the socket outlets for a correct matching

    - no earth connection is realized with 2P+E 16 A 250 V~ French

    standard plug

    Cover plates dimensions:

    - 10714: 98x76 mm - flush depth: 40 mm

    - 10764: 120x76 mm - flush depth: 40 mm

    - 10765: 120x76 mm - flush depth: 40 mm

    - 10719: 98x76 mm - flush depth: 40.5 mm

    - 10768: 120x76 mm - flush depth: 40.5 mm

  • 7/24/2019 B_C10038.23757

    25/4823

    LINEA

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    Socket outlets

    Italian standard socket outlet 250 V~10714 2P+E 16 A SICURY socket outlet, Italian standard P30 (lateral and central earth contacts) with ivory self-bearing cover plate for round

    mounting boxes and screw covering strips 10798.01

    10764 As above, with ivory self-bearing cover plate for rectangular mounting boxes and screw covering strips 10797.0110765 As above + 1-gang, with ivory self-bearing cover plate for rectangular mounting boxes and screw covering strips 10798.01

    10714 10764

    10765

    Italian standard socket outlet 250 V~10719 2P+E 16 A SICURY socket outlet, universal, for 2P 2,5 A Europlugs, 2P and 2P+E 10 A and 16 A Italian standard plugs, 2P+E 16 A

    250 V~ German standard plugs, 2P 15 A 125 V~ American standard plugs with non-polarized flat blades - with ivory self-bearing coverplate for round mounting boxes and screw covering strips 10798.01.No earth connection with French standard plug

    10768 2P+E 16 A SICURY socket outlet, universal, for 2P 2,5 A Europlugs, 2P and 2P+E 10 A and 16 A Italian standard plugs, 2P+E 16 A250 V~ German standard plugs, 2P 15 A 125 V~ American standard plugs with non-polarized flat blades - with ivory self-bearing coverplate for rectangular mounting boxes and screw covering strips 10797.01.No earth connection with French standard plug

    10719 10768

  • 7/24/2019 B_C10038.23757

    26/4824

    Devices

    Other standard plugs and socket outlets

    Italian standard plug S10

    Italian standard plug S11

    2P 2,5 A Europlug

    2P+E 16 A 250 V~ German standard plug

    2P+E 16 A 250 V~ German/French standard plug

    2P 15 A 125 V~ American standard plug

    2P 15 A 250 V~ American standard plug

    2P+E 15 A 127 V~ American standard plug

    2P+E 15 A 250 V~ American standard plug

    10194 10195 - 10196 10197

    Standard plug matching the socket outlet

    Standard plug matching the socket outlet

    without continuity of earth connection

    10192 10191

    10200

    2P+E 10 A 250 V~ Argentinian standard plug

    2P+E 20 A 250 V~ Argentinian standard plug

    10206

    Socket outlets - TECHNICAL CHARACTERISTICS

    Foreign standard VIMAR plugs00230: 2P+E 16 A plug 250 V~ German standard

    00231: 2P+E 16 A plug 250 V~ German/French standard

    00241: 2P+E 16 A plug 250 V~ German/French standard

    01096: 2P+E 15 A plug 127 V~ American and Saudi Arabian standard

    01105: 2P+E 15 A plug 250 V~ American standard

  • 7/24/2019 B_C10038.23757

    27/4825

    LINEA

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    Socket outlets

    Other standard socket outlet*10192 2P 15 A 250 V~ socket outlet for 2P 15 A 125 V~ American standard plugs with non-polarized flat blades and for 2P plugs with 4 mm

    and 4,8 mm pins, 19 mm distance between centres*10191 2P+E 15 A 250 V~ socket outlet, for 2P 15 A 125 V~ American standard plugs with polarized and non polarized flat blades and for 2P

    and 2P+E plugs with 4 mm pins, 19 mm distance between centres

    10191

    10192

    24

    35

    21,5

    32,5

    Other standard socket outlets*10194 2P 15 A 250 V~ socket outlet, for 2P American standard plugs (15 A 125 V~ polarized and non-polarized + 15 A 250 V~ flat blades)

    and for 2P plugs with 4 mm and 4,8 mm pins, 19 mm distance between centres*10195 2P+E 15 A 127 V~ socket outlet, American and Saudi Arabian standards*10197 2P+E 15 A 250 V~ socket outlet, American standard*10196 Two 2P+E 15 A 127 V~ socket outlets, American and Saudi Arabian standards - 3 modules

    10195

    1019610197

    10194

    26

    37

    24

    35

    24

    35

    21,5

    32,5

    Other standard socket outlet*10200 2P+E 10 A 250 V~ socket outlet, Argentinian standard

    *10206 2P+E 20 A 250 V~ SICURY socket outlet, Argentinian standard - 2 modules

    10206

    10200

    24

    35

    21,5

    32,5

  • 7/24/2019 B_C10038.23757

    28/4826

    Devices

    Socket outlets for signal reception - TECHNICAL CHARACTERISTICS

    Telephone socket outlets

    Technical specifications connection with screw terminals

    TX

    L2 L1

    TS TSTX

    T2

    L2 L1

    TSTX

    T

    A

    2

    B

    L2 L1

    10215

    RJ11

    4 contacts

    10216

    RJ12

    6 contacts

    10217

    RJ45

    8 contacts

    L1

    TS

    L2

    TX

    10215

    L1

    TS

    L2

    TX

    10215

    L1

    L2

    L1

    TS

    L2

    TX

    10215

    NOTEL1-TS line is interrupted when the socket connectors are wired as shown above: if thetelephone plug is withdrawn from a socket connector, all socket connectors connectedafter it in the installation would be disconnected. To overcome this incovenience, insert aplug with L1-TS bridge.

    Wiring diagram for 10215Wiring diagrams for telephone socket outlets

  • 7/24/2019 B_C10038.23757

    29/4827

    LINEA

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    Socket outlets for signal reception

    Special socket outlet10159 2P 6 A 24 V (SELV) polarized socket outlet for 01616 and 01617 plugs (1 3 mm pin and 1 4 mm pin, 12,4 mm distance between

    centres). For Hi-Fi installations, HFTR reception etc..

    10159

    18

    26

    Phone jacks10215 RJ11 phone jack, 6-position 4-conductor (6/4), screw terminals10216 RJ12 phone jack, 6-position 6-conductor (6/6), screw terminals10217 RJ45 phone jack, 8-position 8-conductor (8/8), screw terminals

    34,5

    42,5

    102151021610217

  • 7/24/2019 B_C10038.23757

    30/4828

    Devices

    Coaxial TV-RD-SAT 5-2400 MHz socket outlets - TECHNICAL CHARACTERISTICS

    Scope connect user equipments to systems for the distribution of ana-

    logic or digital sound and video signals, from terrestrial, satellite

    or cable link, in the 5-2400 MHz frequency band

    permit the connection of a single device (e.g. TV or SAT

    receiver)

    can be used for satellite Internet applications and, thanks to the

    5-40 MHz return channel, also for interactive functions (hotel

    communications and cable TV)

    a choice of single connection socket outlets allows the passage

    of d.c. current and control signals, and of through-line socket

    outlets with three different attenuation ratings and ensures

    optimal utilisation on any type of individual or central

    distribution configuration (see table on the left)

    The range

    1 single connection socket outlet which allows the passage of

    d.c. current and control signals (24 V 500 mA max)

    3 through-line socket outlets with:- connection attenuation 10 dB

    - connection attenuation 15 dB

    The through-line socket outlets can become line-end socket

    outlets if closed with the special terminal resistor 16330.

    They allow d.c. current and control signals (24 V 500 mA max)

    to pass through the line, but not to the user port (IEC 60169-2

    male connector).

    Technical specifications frequency range: 5-2400 MHz

    output: IEC 60169-2 male connector

    return channel in 5-40 MHz band shielding efficiency: A class

    cable dimensions:

    - internal wire 3 mm max

    - external insulating sheath: 5-7 mm

    Conformity to StandardsEN 50083-1, EN 50083-4 Standards

    EMC Directive

    EN 50083-2 Standard

    How to connect

    Programmes - Applications

    Terrestrial TV

    Radio

    receiver

    STB

    (Set Top Box)

    Satellite TV and radio

    Programmes - Applications

    Terrestrial radio

    SAT

    IEC 60169-2 male

    IEC 60169-2 male

    IEC 60169-2 male

    IEC 60169-2 male

    Coaxial cable connection SCART cable connection

    Programmes - Applications

    Cable TV (CATV)

    Interactive hotel communications

    Programmes - Applications

    Socket type

    Single connection 1 dB

    Attenuation type

    Connection attenuation (dB)

    Frequencies (MHz)

    40-470 470-862 862-950 950-1750 1750-24005-40

    0,2 0,3 0,3 0,5 0,70,1

    Through-line 10 dB

    Connection attenuation (dB) 10 10 10 10 11,511,5

    Throughpass attenuation (dB) 1,2 1,2 1,3 1,7 21,5

    Through-line 15 dB

    Connection attenuation (dB) 15 15 15 15 1515

    Throughpass attenuation (dB) 0,8 0,8 0,9 1,1 1,40,8

    i i

    i

    Attenuations

    Multiple socket outlets in cascade

    Multiple parallel connected socket outlets

    Combined cascade/parallel connectedMulti-switch for satellite signal distribution

    Multi-switch for combined terrestrial and satellite signal distribution

    Combined cascade/parallelwith IF-IF conversion unit for single-cable distribution of combined terrestrial and satellite signals

    Combined cascade/parallel with modular unit for feedingterrestrial and satellite programs in the 40-862 MHz band(terrestrial)

    Some examples of the supported system topologies

  • 7/24/2019 B_C10038.23757

    31/4829

    LINEA

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    Coaxial TV-RD-SAT 5-2400 MHz socket outlets

    200

    200

    15 82

    120 12

    0

    15 82

    TV-RD-SAT through-line socket outlet

    Cable drop from below Cable drop from above Closing the cord-grip

    Coaxial TV-RD-SAT 5-2400 MHz socket outlet10190.01 Coaxial TV-RD-SAT 5-2400 MHz socket outlet, single connection,with IEC 60169-2 male connector, connection attenuation 1 dB.

    Allows the passage of d.c. current and control signals (24 V 500 mA max).

    10190.01

    28,5

    36,5

    10190.1010190.15

    28,5

    36,5

    Coaxial TV-RD-SAT 5-2400 MHz socket outlet10190.10 Coaxial TV-RD-SAT 5-2400 MHz socket outlet, through-line, with IEC 60169-2 male connector, connection attenuation 10 dB10190.15 As above, connection attenuation 15 dB

    IEC 60169-2 male

    24 V 500 mA max

    Ad: 1 dB

    Single-connection

    IEC 60169-2 male

    Ad: 10 dB

    15 dB

    20 dB

    Through-line

  • 7/24/2019 B_C10038.23757

    32/4830

    Devices

    TV socket outlets - TECHNICAL CHARACTERISTICS

    TV socket outlet

    without attenuation

    Amplifier

    unit

    TV socket

    outlets

    without

    attenuation

    Tap-off

    Amplifier

    unit

    TV socket outlets

    without attenuation

    TV socket outlet

    for line end

    Amplifier

    unit

    08175

    Directional

    TV socket outlets

    Fig. 1 Single down-line Fig. 2 Collective installationline from distribution boxes

    Fig. 3 Collective installationwith looped distribution

    Fig. 4 Collective installationwith looped distribution

    Coaxial 40-862 MHz TV socket outlets

    Technical specifications patented cord-grip for easy and reliable connection of the

    coaxial cable

    captive screw terminals and toothed pressure plate, for the

    central conductor

    realization of the articles with 9,5 output with relevant

    capacitor series connected directly to the internal terminal, or

    through an adequate radiofrequency repeater, to protect the

    installation against dangerous voltages from connected

    receivers ( 4.1.02 Italian standard CEI 12-15)

    TV socket outlet without attenuation: to be used for single

    down-lines or for collective installation lines from distribution

    boxes or tap-offs (Fig. 1 and 2)

    through-line TV socket outlet and line-end socket outlet:

    resistive type with connection attenuation 20 dB for installations

    with several socket outlets connected in cascade (looped

    distribution - Fig. 3)

    TV directional socket outlet, microstrip parallel-line type (see

    table for attenuations); for collective installations with looped

    distribution (figure 4). The line-end socket outlet shall be fitted

    with 75 resistive load 08175

    Dimensions (in mm)

    01644

    17,5

    33

    44

    01645

    17,5

    33

    44

    01634 16,5

    17

    41

    01635 16,5

    17

    41

    01654

    9

    13,

    5

    19,

    8

  • 7/24/2019 B_C10038.23757

    33/4831

    LINEA

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    TV socket outlets

    Coaxial TV 40-862 MHz socket outlet*10178 Coaxial TV socket outlet, single connection, with IEC 60169-2 female connector*10179 Coaxial TV through line, with IEC 60169-2 female connector, throughpass attenuation 3 dB, connection attenuation 20 dB

    30,5

    38,5

    1017810179

    Coaxial F-type socket outlet and terminal resistor10188 Coaxial socket outlet with F-type female connector (IEC 60169-24).

    For frequencies up to 2400 MHz. In/out connection with F-type male connector 01654

    16330 Z 75 terminal resistor for TV-RD-SAT socket outlets line end, for frequencies up to 2400 MHz

    10188

    30,5

    16330

    Coaxial TV-RD-SAT connector for frequencies up to 2400 MHz01644 Coaxial male connector IEC 60169-2, axial cable entry - Z 75 , white

    01645 Coaxial female connector IEC 60169-2, axial cable entry - Z 75 , white01634 Coaxial male connector IEC 60169-2, 90 cable entry - Z 75 , white01635 Coaxial female connector IEC 60169-2, 90 cable entry - Z 75 , white01654 Coaxial male connector type F - Z 75 , for cable RG59 ( external 7 mm).For 20318, 16331, 14318, 08186 and 10188

    01644 01645 01654 01634 01635

  • 7/24/2019 B_C10038.23757

    34/4832

    Devices

    Signalling - Protection - TECHNICAL CHARACTERISTICS

    Bells snd buzzers12 V and 24 V bells and buzzers are to be supplied through

    safety isolating transformer

    Conformity to StandardsLV Directive for 10349, 10363

    Luminous indicator unitsMicrotube lamps

    Conformity to StandardsLV Directive

    A 1,5 F 400 V~ capacitor should be connected in parallel to neon or fluorescent microtubelamps to avoid self-ignition in special circuits

    Assembly

    Fuse carrier

    Conformity to StandardsLV Directive

    Fuse replacing

    Colour of Article Type Voltage W Lamp Bulb Lamp Diffuseremitted light dim.(mm) dim. (mm) colour colour

    white 07054 incandescence 12 V 3 W 7x31 8x15 white white

    white 07055 incandescence 24 V 3 W 7x31 8x15 white white

    orange 07054 incandescence 12 V 3 W 7x31 8x15 white orange

    orange 07055 incandescence 24 V 3 W 7x31 8x15 white orange

    red 07053 neon 110 V~ 0,5 W 6,3x28 red red

    red 07052 neon 250 V~ 0,5 W 6,3x28 red red

    green 07052.V fluorescent 250 V~ 0,5 W 6,3x28 green green

    blue 07052.AZ fluorescent 250 V~ 0,5 W 6,3x28 blue white

    Note Colour of emitted light = colour of microtube lamp + diffuser colour

    Technical specifications of microtube lamps

  • 7/24/2019 B_C10038.23757

    35/4833

    LINEA

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    Signalling - Protection

    Bell and buzzer10349 Bell, 230 V~ 50 Hz 8 VA10363 Buzzer, 230 V~ 50-60 Hz 8 VA

    32

    40

    34

    42

    10349 10363

    Luminous indicator unit10306 Indicator unit for 6,3x28 mm or 7x31 mm lamp, red diffuser. Provided without lamp

    10306

    23

    31,5

    Protection device10370 1P 16 A 250 V~ fuse carrier for 5x20 mm and 6,3x32 mm miniature fuses. Supplied without fuse

    10370

    23

    31

  • 7/24/2019 B_C10038.23757

    36/4834

    Devices

    Regulation - Comfort - TECHNICAL CHARACTERISTICS

    10336 and 10337 - Wiring diagram

    Fuse carrier with

    F5AH fuse

    Fuse carrier with

    F5AH fuse

    Fuse carrier with

    F5AH fuse

    L

    N

    Fuse carrier with

    F5AH fuse

    Fuse carrier with

    F5AH fuse

    L

    N

    L

    N

    L

    N

    L

    N

    Relay

    10340 - Dimmer fo resistive loads

    Conformity to StandardsLV Directive

    EMC Directive

    EN 60669-2-1 Standard

    1 2 3 4

    L

    Diagram 1

    N

    1 2 3 4

    L

    Diagram 2

    N

    1 2 3 4

    L

    Diagram 3

    N

    10472 - Wiring diagrams

    10472 - Electronic time delay switch

    Technical specifications supply voltage: 230 V~ 10% 50-60 Hz

    output relay with contact rating:

    - 6 A 230 V~ for incandescent lamps

    - 2 A 230 V~ for fluorescent lamps and motor-driven equipments

    time setting: 30 s to 15 min it can be connected in parallel with non luminous NO push

    buttons

    Operating control of lighting with time delay switching off through built-in

    push button or through parallel connected non luminous NO

    push buttons:

    - diagram 1: the delay time cycle is resettable only when lightsare off

    - diagram 2: the delay time cycle is resettable also when lights

    are on, pressing on the built-in push button only

    control of lights and household exhaust fans through 2P 1-way

    switch:- diagram 3: simultaneous operation of lights and exhaust fan.

    The delay time cycle starts when lights are switched off and itbe reset by pressing the built-in push button. The exhaust fan

    switches off at the end of the delay t ime cycle.

    Conformity to StandardsLV Directive

    EMC DirectiveEN 60669-2-1 Standard

    Trimmer forthe delay time regulation

    Control push button

    Pilot lamp forlocation in the dark

  • 7/24/2019 B_C10038.23757

    37/4835

    LINEA

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    *Only for Countries not members of the EU

    Regulation - Comfort

    1033710336

    36

    48

    Dimmers for resistive and inductive loads*10336 Dimmer, supply voltage 230 V~ 50-60 Hz for: 60-900 W incandescent lamps, 60-300 VA ferromagnetic transformers, without radio

    interference suppression filter, control and regulation by rotary potentiometer, visible in darkness*10337 Dimmer, supply voltage 120 V~ 50-60 Hz for: 30-500 W incandescent lamps, 30-300 VA ferromagnetic transformers, without radio

    interference suppression filter, control and regulation by rotary potentiometer, visible in darkness

    10472

    32,5

    43

    Electronic time delay switch10472 Electronic time delay switch for control of stair lighting, utility rooms, exhaust fans, NO 6 A 230 V~ relay output, visible in darkness,

    supply voltage 230 V~ 50-60 Hz - 2 modules

  • 7/24/2019 B_C10038.23757

    38/4836

    Microtube lamps and fuses

    Accessories

    Incandescent microtube lamps07054 7x31 mm, 8x15 mm bulb, 12 V 3 W, white light07055 7x31 mm, 8x15 mm bulb, 24 V 3 W, white light

    07054

    07055

    Fuses07050.02 2 A 250 V~ miniature fuse, 5x20 mm, glass tube07050.04 4 A 250 V~ miniature fuse, 5x20 mm, glass tube07050.06 6 A 250 V~ miniature fuse, 5x20 mm, glass tube07050.08 8 A 250 V~ miniature fuse, 5x20 mm, glass tube

    07050.10 10 A 250 V~ miniature fuse, 5x20 mm, glass tube07050.HF.2.5 F2,5AH fast-blow fuse with high breaking capacity, breaking capacity 1500 A, steatite tube07050.HF.5 F5AH 6,3x32 fast-blow fuse with high breaking capacity, breaking capacity 1500 A, steatite tube07050.HFF.16 FF16AH extra fast-blow fuse with high breaking capacity, breaking capacity 1500 A, steatite tube

    07050... 07050.HF... 07050.HFF.16

    Neon and fluorescent microtube lamps07053 Neon glow lamp, 6,3x28 mm, 110 V~ 0,5 W, red. Lamp life: 15000 hours (with rated voltage)

    07052 Neon glow lamp, 6,3x28 mm, 250 V~ 0.5 W, red. Lamp life: 15000 hours (with rated voltage)07052.V Fluorescent lamp, 6.3x28 mm 250 V~ 0.5 W, green. Lamp life: 10000 hours (with rated voltage)07052.AZ Fluorescent lamp, 6.3x28 mm 250 V~ 0.5 W, blue. Lamp life: 5000 hours (with rated voltage)The above indicated colour is the colour of emitted light

    07053...07052...

  • 7/24/2019 B_C10038.23757

    39/4837

    LINEA

    Side views show the overall dimensions and the flush depth in mm

    Mounting boxes and cover plates, page 38

    Signalling units - Screws

    Signalling unit10490 Incandescent signalling unit, 12 V~ 0,5 W, white light. Life of the signalling unit: 10000 hours (with rated voltage)10491 Incandescent signalling unit, 24 V~ 0,5 W, white light. Life of the signalling unit: 10000 hours (with rated voltage)10492 Neon signalling unit, 110 V~ 0,5 W, red light. Life of the signalling unit: 25000 hours (with rated voltage)10493 Neon signalling unit, 250 V~ 0,5 W, red light. Life of the signalling unit: 25000 hours (with rated voltage)

    10493.V Fluorescent signalling unit, 250 V~ 0,5 W, green light.Life of the signalling unit: 10000 hours (with rated voltage)

    10493.AZ Fluorescent signalling unit, 250 V~ 0,5 W, blue light. Life of the signalling unit: 5000 hours (with rated voltage)

    1049010491

    10492...

    10493...

    Technical specifications

    Incandescent lamp life: 200 hours.

    Note

    Lamp life can be considerably increased by lowering the

    power supply voltage: for example, a 20% reduction in sup-

    ply voltage increases lamp life by approximately a factor of

    10.

    The table overleaf shows the variations in:

    lamp life

    current

    efficiency

    luminous flux

    obtained by varying the supply voltage.

    50

    Life

    LifeE

    fficien

    cy

    Efficie

    ncy

    Lumin

    ousflux

    Lumin

    ousflu

    x

    30

    20

    10

    8

    6

    4

    2

    100% = 1

    0,8

    0,7

    0,6

    0,5

    0,4

    0,3

    0,2

    0,15

    7

    6

    5

    4

    3

    2

    1,5

    100% = 1

    0,0260% 80% 100% 120% 140%

    (100% = rated voltage)

    0,03

    0,04

    0,06

    0,08

    0,1

    0,2

    0,3

    0,4

    0,8

    0,60,5

    1,2

    M

    ultiplicationfactor

    Supply voltage

    Curren

    t

    Current

    Incandescent lamps

    Screw07935 19 mm length, with cross-slotted head for mounting frame fixing on mounting boxes07937 35 mm length, with cross-slotted head for mounting frame fixing on mounting boxes07939 50 mm length, with cross-slotted head for mounting frame fixing on mounting boxes

    07935 07937 07939

  • 7/24/2019 B_C10038.23757

    40/4838

    Flush mounting - 1- and 2-module self-bearing cover plates

    V71001*GW 650 C, light blue

    V71001.AU*GW 960 C, black*) Not suitable for:

    10064..., 10065..., 10081...

    Flush mounting - 1-, 2- and 3-module cover plates

    Flush and surface mounting

    Types of mounting

    VIMAR VIMAR

    10705With claws.

    Dimensions:

    98x76 mm

    10706With claws.

    Dimensions:

    98x76 mm

    VIMAR

    VIMAR

    VIMAR

    VIMAR

    VIMARVIMAR

    VIMAR

    VIMA R

    09968*,ivory*) Not suitable for: 10064..., 10065..., 10081...

    V71303GW 650 C,

    light blue

    V71303.AUGW 960 C, black

    V71613For hollow walls

    GW 850 C,

    light blue

    09973,ivory

    09973.ARAL 9001 ivory

    09974, ivory

    09974.ARAL 9001 ivory

    107351-module.

    Dimensions:

    120x76 mm

    106351-module.

    Dimensions:

    119,5x75,5 mm

    10735.U1-module.

    Dimensions:

    76x120 mm

    107362-module.

    Dimensions:

    120x76 mm

    106373-module.

    Dimensions:

    119,5x75,5 mm

    106362-module.

    Dimensions:

    119,5x75,5 mm

    107373-module.

    Dimensions:

    120x76 mm

    10660Blaking module.

    Dimensions:

    119,5x75,5 mm

    105313-module,with screws

  • 7/24/2019 B_C10038.23757

    41/4839

    LINEA

    Flush mounting - 5-, 6- and 3+3-module self-bearing cover plates

    Flush and surface mounting - Cover plates

    VIMAR

    VIMAR

    VIMAR

    107384-module.

    Dimensions:

    142,5x76 mm

    10739

    5-module.Dimensions:

    164,5x76 mm

    107406-module (3+3).

    Dimensions:

    164,5x76 mm

    V71304GW 650 C,

    light blue

    V71304.AUGW 960 C, black

    V71614For hollow walls

    GW 850 C,

    light blue

    09996GW 650 C,

    light blue

    09996.AUGW 960 C, black

    V71305

    GW 650 C,light blue

    V71305.AUGW 960 C, black

    Range of cover plates

    Anodized aluminium cover plate, Gold Self-bearing cover plate

    with ivory strips

  • 7/24/2019 B_C10038.23757

    42/4840

    ScopeThe IP55 surface boxes extend the utilization possibilities of

    Linea series in locations where the IP55 protection degree is re-

    quired (industrial and agricultural environments, buildings sites,

    tourists harbours, sport installations, gardens, camping sites,

    ecc.).

    They furthermore permit to realize electrical installations in loca-

    tions where explosions or fires are liable to occur, in compliance

    with Italian standards EN 60079 and CEI 64-2.

    Technical specifications protection degree Ip 55 in compliance with CEI EN 60529

    (CEI 70-1)

    granted if installation has been done according to good engi-

    neering practice, with the use of appropriate cable/conduit en-

    tries, glands and coupling accessories and with closed cover

    resistance to abnormal heat and to fire (Glow Wire test):

    650 C

    resistance to ageing according to CEI 23-48: 7 days at 70 C resistance to heat: ball-pressure test according to Italian

    Standard CEI 23-48: 70 C

    Conformity to StandardsLV Directive

    EN 60670-1 Standard

    IP55 boxes - TECHNICAL CHARACTERISTICS

    Surface mounting boxes

    12330

    68 65,5

    83

    12335

    68 65,5

    83

    VIMAR

    12352

    68 65,5

    83

    12331

    68 65,5

    83

    12202

    68 65,5

    83

    12201

    68 65,5

    83

    Dimensions (in mm)

  • 7/24/2019 B_C10038.23757

    43/4841

    LINEA

    IP55 boxes

    1- and 2-module box12201 1-module surface mounting box12202 2-module surface mounting box

    1220212201

    Devices supplied with surface mounting box12331 2P+E 16 A 250 V~ SICURY socket outlet, Italian standard P30 (lateral and central earth contacts)12335 2P+E 16 A 250 V~SICURY socket outlet, universal, for 2P 2,5 A Europlugs, 2P and 2P+E 10 A and 16 A Italian standard plugs,

    2P+E 16 A German standard plugs, 2P 15 A 125 V~ American standard plugs with non-polarized flat blades.No earth connection is realized with French standard plug

    12330 2P+E 16 A 250 V~ SICURY socket outletm German standard12352 1P NO 10 A 12-24 V (SELV) push button, with luminous name-plate, for 12-24 V 3 W 7x31 mm microtube lamps.

    Supplied without lamp

    12335

    12330

    12331

    12352

  • 7/24/2019 B_C10038.23757

    44/4842

    Information

    Marks and certifications

    General notesVIMAR products are built according to all safety measure, in

    full compliance with the requirements of the Laws 186/68 and

    791/77.

    If they are assembled, installed and used properly, they do not

    constitute a hazard to the safety of people, pets and property.

    VIMAR realizes electrical installations in accordance with the

    requirements of the electrical installation Laws 46/90.

    All the VIMAR products which are regulated by EEC Directives

    (EMCDirective, LV Directive, R&TTE Directive) are in compli-

    ance with the essential requirements thereof.

    With the CE mark, they may be marketed and used within the

    European Union without further formalities.

    The CE MARKING placed on the product and/or on the

    packing and/or on any usage warnings that may accompany

    the product, "indicate compliance with the Directives" above

    mentioned.

    Product managerCertification by recognized third-party boards is voluntary and

    adds value to the product provided with a mark of compliance.

    In some countries certification is compulsory and represents

    an essential market requisite.

    Certified products are subject to permanent inspection by the

    recognized third-party boards, through both inspections of the

    manufacturing site and market spot-checks.

    The trademarks and certifications listed below refer to the

    products which dave been approved as of the printing date

    of this catalogue.

    Approval may be in progress for other products, or unplanned

    for those products which are not considered by standards,

    yet, and thus not subject to marking procedures.

    Marks and certifications

    IMQ - Italy IMQ - Italy LCIE - France

    SIQ - Slovenia VDE - Germany GOSSTANDART - Russia

    TSE - Turkey

    MEEI - HungaryKONCAR - Croatia

    UL - USA ENEC IMQ ENEC VDE

    Istituto Italiano delMarchio di Qualit

    IMQ - ItalyMarchio IMQ-UNICIG

    per gli apparecchi utilizzatoria gas e relativi accessori

    Certificato conSorveglianza IMQ

    Laboratoire Centraldes Industries Electriques

    Slovenian Institute ofQuality andMetrology

    Testing and CertificationInstitute

    Turkish StandardsInstitution

    BBJ-SEP - PolandAssociation of PolishElectrical Engineers

    Testing laboratory BBJ-SEP

    EZ - Czech Republic AENOR - SpainSpanish Associationfor Standardisationand Certification

    ElectrotechnicalTesting Institute

    Hungarian Institute forTesting and Certificationof Electrical Equipment

    Electrical EngineeringInstitute

    UnderwritersLaboratories Inc.

    European NormsElectrical Certification

    European NormsElectrical Certification

    NOM - Mexico

    1

    RAEE Directive

    2 3 4 5

    6 7 8 9 10

    11 12 13 14 15

    16 17

    22

    18 19

    IMQ - ItalyMarchio IMQ

    Sistemi di Sicurezza

    21

    IRAM - ArgentinaIstituto Argentinode Normalizacin

    20

    CERT

    IFI

    CACI

    NDE C

    ONFORMIDADDELAFA

    BRIC

    ACIN

    SELLO

    2071

    SEV - Switzerland

    CQC - China

    Swiss ElectrotechnicalAssociation

    China QualityCertification Center

    ENEC VEEuropean Norms

    Electrical Certification

    IQC - ArgentinaInternational

    Quality Certification

    24 25

    CSA - CanadaCanadian Standard

    Association

    99

    The equipment marked with this symbol are included in the application of the RAEE Directive and will have to be disposed separately from the urban

    waste and returned to the distributor at the moment of the purchase of a new equivalent equipment.

    23

    INMETRO - BrazilTUV Rheinland do Brasil

  • 7/24/2019 B_C10038.23757

    45/4843

    LINEA

    Index

    Article Description Packquantity

    Page Marks(See the marks table

    page 42)

    Notes

    V71001 Flush mounting box 60mm light blue 200 38 1 - 8

    V71001.AU Flush mounting box 60mm light black 200 38 1 - 8

    V71303 Flush mounting box 3M light blue 300 38 1 - 8

    V71303.AU Flush mounting box 3M black 300 38 1 - 8V71304 Flush mounting box 4M light blue 96 39 1 - 8

    V71304.AU Flush mounting box 4M black 96 39 1 - 8

    V71305 Flush mounting box 5M light blue 84 39 1 - 8

    V71305.AU Flush mounting box 5M black 84 39 1 - 8

    V71613 Flush-mount box 3M for hollow walls blue 135 38 1

    V71614 Flush-mount box 4M for hollow walls blue 110 38 1

    01634 TV-RD-SAT male 90-connector white 50 31 1

    01635 TV-RD-SAT female 90-connector white 50 31 1

    01644 TV-RD-SAT male axial connector white 50 31 1

    01645 TV-RD-SAT female axial connector white 50 31 1

    01654 TV-RD-SAT F type male connector 100 31 1

    07050.02 2A 5x20mm fuse 50 3607050.04 4A 5x20mm fuse 50 36

    07050.06 6A 5x20mm fuse 50 36

    07050.08 8A 5x20mm fuse 50 36

    07050.10 10A 5x20mm fuse 50 36

    07050.HF.2.5 5x20mm F2,5AH quick-acting fuse 50 36

    07050.HF.5 5x20mm F5AH quick-acting fuse 50 36 07050.HFF.16 5x20mm FF16AH extra quick-acting fuse 50 36

    07052 250V 0,5W neon lamp red 50 3607052.AZ 250V 0,5W fluorescent lamp light blue 50 3607052.V 250V 0,5W fluorescent lamp green 50 3607053 110V 0,5W neon lamp red 50 3607054 12V 3W incandescent lamp white 50 3607055 24V 3W incandescent lamp white 50 3607935 Screw for frame fixing - 19mm 100 3707937 Screw for frame fixing - 35mm 500 3707939 Screw for frame fixing - 50 mm 500 3709968 Surface-box+bottom 3M 40mm depth 20 38 1

    09973 Surface-box 3M 40mm depth white 20 38 1

    09973.A Surface-box 3M 40mm depth ivory 20 38 1

    09974 Surface-box 3M 48mm depth white 20 38 1

    09974.A Surface-box 3M 48mm depth ivory 20 38 1

    09996 Flush-box 6(3+3)M blue 20 39 1

    09996.AU Flush-box 6(3+3)M self-extinguish black 20 38 1

    100001P 10AX 1-way switch

    50 151 - 10 - 14 - 19 - 20

    10001 1P 16AX 1-way switch 50 15 1 - 10 - 14 - 19 - 20

    10004 1P 10AX 2-way switch 50 15 1 - 10 - 14 - 19 - 20

    10005 1P 16AX 2-way switch 50 15 1 - 10 - 14 - 19 - 20

    10013 1P 16AX reversing switch 50 17 1 - 10 - 14 - 19 - 20

    10016 2P 16AX 1-way switch 50 15 1 - 10 - 14 - 19 - 20

    10037 1P 10AX 1-way switch luminous 50 15 1 - 10 - 14 - 19 - 20

    10038 1P 10AX 2-way switch luminous 50 15 1 - 10 - 14 - 19 - 20

    10140 2P+E 10A P11 outlet 50 21 1

    10145 2P+E 16A P17/11 outlet 50 21 1

    10159 Polarized 2P 6A 24V SELV outlet 50 27

    * 10178 TV 9,5IEC single conn. outlet 50 31* 10179 TV 9,5IEC through-line outlet 50 31

    10188 F type female socket connector 10 31 1

    10190.01 TV-RD-SAT single conn.male outlet 1dB 20 29 1

    10190.10 TV-RD-SAT through-line male outlet 10dB 20 29 1

    10190.15 TV-RD-SAT through-line male outlet 15dB 20 29 1

    * 10191 2P+E 15A USA+EU outlet - 4mm 50 25 19* 10192 2P 15A USA+EU outlet - 4,8mm 50 25 19* 10194 2P 15A USA+EU outlet - 4,8mm 50 25 19* 10195 2P+E 15A USA+SASO outlet 50 25 19* 10196 Two 2P+E 15A USA+SASO outlets 20 25 19* 10197 2P+E 15A American outlet 50 25 19* 10200 2P+E 10A Argentinian outlet 50 25 20* 10206 2P+E 20A Argentinian outlet 10 25 20

    10215 RJ11 phone jack 6/4 20 2710216 RJ12 phone jack 6/6 20 2710217 RJ45 phone jack 8/8 20 2710235 1P NO 10A push button general symbol 50 17 1 - 10 - 14 - 19 - 20

    10236 1P NO 10A push button bell symbol 50 17 1 - 10 - 14 - 19 - 20

    10268 1P NO 10A push button general symbol lms 50 17 1 - 10 - 14 - 19 - 20

    10270 1P NO 10A cord-operated push button 20 17 1 - 10 - 14 - 20

    10280 1P 10A 2-way push button 20 19 1 - 10 - 14 - 20

    10285 1P 10AX 2-way switch 20 19 1 - 10 - 14 - 20

    10306 Red indicator unit 50 33

    10314 Cable outlet with cord-grip 50 15 1

    10319 Blank module 50 15 1

    * 10336 Dimmer 230V 60-900W/60-300VA 20 35 * 10337 Dimmer 120V 30-500W/30-300VA 20 35 19

    10349 230V 50Hz bell 50 33 3

    10363 230V 50-60Hz buzzer 50 33 3

    10370 1P 16A 250V fuse carrier 50 33

    10472 230V time-delay switch 10 35

    *Only for Countries not members of the EU

  • 7/24/2019 B_C10038.23757

    46/4844

    Article Description Packquantity

    Page Marks(See the marks table

    page 42)

    Notes

    10490 12V incandescent signalling unit white 50 37

    10491 24V incandescent signalling unit white 50 37

    10492 110V neon signalling unit red 50 37

    10493 250V neon signalling unit red 50 3710493.AZ 250V fluorescent signalling unit blue 50 3710493.V 250V fluorescent signalling unit green 50 3710531 Frame 3M +screws 50 38 1

    10635 Plate 1M aluminium gold 20 38 1

    10636 Plate 2M aluminium gold 20 38 1

    10637 Plate 3M aluminium gold 20 38 1

    10660 Blanking plate aluminium gold 20 38 1

    10705 Self-bearing plate 1M for 60mm box 20 38 1

    10706 Self-bearing plate 2M for 60mm box 20 38 1

    10714 2P+E 16A P30 outlet for 60mm box 10 23 1 - 10

    10719 2P+E 16A universal outlet for 60mm box 10 23 19

    10735 Self-bearing plate 1M box 3M 20 38 1

    10735.U Self-bearing plate 1M USA type 20 38 1

    10736 Self-bearing plate 2M box 3M 20 38 1

    10737 Self-bearing plate 3M box 3M 20 38 1

    10738 Self-bearing plate 4M box 4M 10 39 1

    10739 Self-bearing plate 5M box 5M 10 39 1

    10740 Self-bearing plate 6M box 6M 10 39 110764 2P+E 16A P30 outlet box 3M 10 23 1 - 10

    10765 2P+E 16A P30 outlet+1M box 3M 10 23 1 - 10

    10768 2P+E 16A universal outlet for box 3M 10 23 19

    10773 10A 12-24V name-plate push box 3M 10 19

    12201 IP55 enclosure for Linea 1M 10 41 1

    12202 IP55 enclosure for Linea 2M 10 41 1

    12330 IP55 2P+E 16A German SICURY outlet 10 4112331 IP55 2P+E 16A P30 outlet 10 41 1

    12335 IP55 2P+E 16A universal outlet 10 4112352 IP55 1P NO 12-24V name-plate push button 10 4116330 Terminal resistor - 75ohm 50 31

    Index

    Index

  • 7/24/2019 B_C10038.23757

    47/48

    Terms and conditions of sale

    1. The contractual relationship resulting from the acceptance of each

    individual order is regulated by the rules described in these general

    terms of sale.

    The purchaser waives any other general purchasing conditions,

    unless otherwise specifically accepted in writing by VIMAR.

    2. The purchase order is irrevocable and binding for the purchaser,and shall be considered accepted when the purchaser receives

    formal confirmation thereof from VIMAR.

    Once confirmed, the purchase order may not be cancelled without

    the previous written consent of VIMAR. In this event, VIMAR shall

    have the right to a suitable indemnity for the expenses and costs

    sustained in beginning to fulfil the order.

    3. The prices indicated in the sale catalogues/price lists are purely

    indicative, and may change during the validity period of the some

    catalogues/price lists due to increased production costs. Once

    confirmed according to the procedures set forth in art. 2, the

    sale prices indicated in the order shall become binding, except

    in the event of unforeseen increases in production costs beyond

    VIMAR's control. In this event VIMAR shall inform the purchaser of

    the price increase, indicating the cause thereof.

    4. Delivery terms are purely indicative unless specifically agreed

    otherwise. Should the manufacturer be unable to fulfil the order

    due to circumstances of force majeure, irregular supply of raw

    materials or other unforeseeable circumstances, the terms of

    delivery shall be considered extended, and the new terms will be

    established by mutual agreement between the parties.

    5. Risk is transferred to the purchaser when the products are deliv-

    ered to the personnel indicated by the latter. The purchaser shall

    indicate the selected means of shipment while ordering. Should no

    shipping means be indicated, the VIMAR shall choose the means

    of shipment for the products, with no right to claim.

    VIMAR is exempt from any liability, with particular regard to theft,

    breakdowns, or tampering that may occur during the shipment.

    The packing costs for the products shall be met by the purchaser

    and invoiced at cost.

    6. The purchaser undertakes to verify the quantity and state of the

    packages shipped in confrontation with the carrier or forwarding

    agent.

    Any complaints regarding quantity discrepancies or damaged

    packages must be notified within 8 days from the receipt of the

    merchandise. No products may be returned unless previously

    agreed upon with VIMAR. In the case of authorized returns, the

    products returned via free port and packing free of charge, shall

    be credited at the purchase price minus 10% for inspection and

    repackaging costs.

    7. The product guarantee issued to the end user shall be deemed

    to be a contractual guarantee pursuant to s. 1519(7) of the Civil

    Code, with the result that the consumers rights expressly laid

    down by legislation on the sale of consumer goods is not preju-diced in any way. As the consequent the consumer may always

    enforce such rights against the vendor, on the terms and condi-

    tions laid down in the said legislation and in this contractual guar-

    antee.

    The products are guaranteed for the period of three yearsfrom

    the date of purchase. In any event, in order to enforce the guaran-

    tee, the purchaser must report the non-conformity in writing to the

    vendor within two months of the date of its discovery. Whether the

    purchaser fail to do it by the expiry its rights will lapse.

    In the event of non-conformity of the products sold, the consumer

    may request their repair or replacement. As specified in s. 1519(4)

    of the Civil Code, if the remedy requested is objectively impossible

    or excessively onerous, involving considerable, unreasonable costs

    for the vendor, VIMAR will restore the conformity of the product by

    activating the alternative remedy. In any event, in accordance withthe last paragraph of s. 1519(4) of the Civil Code, a slight non-

    conformity for which it would be objectively impossible or

    excessively onerous for VIMAR to provide the remedies specified

    above shall not entitle the consumer to terminate the contract of

    sale. VIMAR guarantees to repair or replace non-confirming goods

    free of charge. The consumer has the responsibility for demonstrat-

    ing that this guarantee is still valid by producing a delivery docu-

    ment issued by the vendor or other documentary evidence (fiscalreceipt, till receipt or the like, product code, orders, contract, etc.)

    which shows the vendors name and the date of the sale. The

    guarantee shall not operate in the event of improper use of the

    goods, and in particular in the event of use thereof for commercial,

    business or professional. In any at these cases the terms of ss.

    1490 et seq. of the Civil Code remain applicable. Equally, non-

    conformities due to negligent or careless use (e.g. failure to comply

    with the instructions for operation of the equipment), installation

    or maintenance performed by unauthorised personnel, damages

    caused during transport or by circumstances unrelated to manu-

    facturing defects and/or non-conformity of the product are not

    covered by the guarantee. VIMAR declines all liability for any dam-

    age or injury which may be caused directly or indirectly to persons,

    property and domestic animals as a result of failure to comply with

    the directions given in the instruction book, in particular those relat-ing to installation, use and maintenance of the product.

    8. The products must be installed and/or used in compliance with

    their technical specifications and the instructions provided by

    VIMAR; they must also be installed and/or used in observance of

    safety regulations and requirements governing the installation and/

    or use of electrical material in force in the country where the prod-

    ucts are installed and/or used.

    For this purpose the purchaser expressly relieves VIMAR of

    any liability in regard to improper use, failure to observe safety

    standards, technical specifications and operating instructions.

    Products that do not comply with the standards and/or technical

    specifications in force within the European Union shall be supplied

    only to those purchasers who specify in the order that the destination

    country is not a member of the European Union, and who state

    that all necessary investigations have been carried out as to the

    compatibility of safety standards in force in the non-EU country for

    which they are intended.

    9. Payments must be made to the registered offices of VIMAR.

    Failure to pay invoices, in full or in part, beyond the established

    due date shall immediately lead to the application of interests at

    the legal rate, in addition to any bank charges and commissions.

    Failure to pay for any reason shall authorize VIMAR to suspend

    additional shipments of material.

    10.As per the terms of art. 10 of the law 675/96, the purchaser is

    hereby informed that all personal information shall be entered into

    the VIMAR database. That is necessary to uphold the contractual

    relationship correctly in and compliance with certain legal

    requirements, as well as for statistical, commercial, marketing,

    promotional purposes, credit protection, management and transferthereof.

    The purchasers personal information is processed by automated

    means and by authorized persons, with the use of security

    measures aimed at ensuring confidentiality.

    VIMAR S.p.A. is the owner of processed data, whom the purchas-

    er may contact to exercise his rights as set forth in article 13 of the

    law cited above.

    To this end the purchaser is hereby informed that he may access

    his own personal information at any time, and request that it be

    updated, corrected, or deleted and/or refuse to allow processing

    thereof.

    11. The rights and obligations of the parties are regulated by the Italian

    law. The Court of Bassano del Grappa has non-exclusive jurisdic-

    tion over any controversy that may arise in relation to the sale of

    the products. The purchaser accepts irrevocably the jurisdiction of

    the Court of Bassano del Grappa should VIMAR file suit with this

    court.

    LINEA

  • 7/24/2019 B_C10038.23757

    48/48