32
BER1530 Data Transmission Analyzer User’s Manual V2.0 DADI Telecom

BER-1530 Data Transmission Analyzer Users Manual

Embed Size (px)

DESCRIPTION

Data Transmission Analyzer Users Manual

Citation preview

  • BER1530

    DataTransmissionAnalyzer

    UsersManual

    V2.0

    DADITelecom

  • ExceptionClauseThis information and all other documents in printed orelectronicformareonlyprovidedforreference.Althougheffortshavealreadybeenmadetoconfirmtheintegralityand accuracy of this information, the Liuzhou DadiTelecommunication Equipment Co., Ltd. Just offers thisinformation and all other documents As Is (theoriginal)withoutanyguarantee,andrefusestoprovideany guarantees within the range permitted as wide aspossible, including but not limited to those guaranteesconcerning the implicated marketability,noninfringement and the suitability to specificapplications In addition, the Liuzhou DadiTelecommunicationEquipmentCo.,Ltd.Willnottaketheresponsibility for any damages due to the use of suchinformation or other documents (including but notlimited to any direct, indirect, inevitable or accidentalones). Though some contents may supplement eachother, no contents included in such information or anyotherdocumentswillmakeanyguaranteesorstatementsof the LiuzhouDadi Telecommunication Equipment Co.,Ltd (or its suppliers or licensers), and any changes tothoseclausesapplicabletothe licenseagreementofthissoftwareaswell.

    CopyrightThisproductisundertheprotectionofthecopyrightlaw.

    Withouttheauthorization inwritingbytheLiuzhouDadi

    Telecommunication Equipment Co., Ltd. In advance, no

    one is allowed to copy, print, adapt, translate or

    abbreviateallorpartofthisproductanddocumentsinto

    any electronic or machinereadable forms, unless

  • otherwise expressly provided in this software license

    agreement.

    All rights reserved 2005 2012. Liuzhou Dadi

    TelecommunicationEquipmentCo.,Ltd

    DADIScience&TechnologyDistrict,Liuzhou

    New & Hightech industrial Development

    Zone,Liuzhou,Guangxi,China

    Allrightsreserved.PrintedinChina.

    Trademark

    Dadi is the registered trademark of the Liuzhou DadiTelecommunication Equipment Co., Ltd. In China andother countries. Pentium and Intel are the registeredtrademarksof the IntelCorporation inU.S.A. andothercountries. Windows 2000 is the trademark of theMicrosoftCorporation inU.S.A.orothercountries.Logossuch as ActiveX, Microsoft, NetMeeting, PowerPoint,Windows,WindowsNTandWindowsare the registeredtrademarks of the Microsoft Corporation in U.S.A. orother countries. The names of other products andcompanies mentioned may be the trademarks orregisteredtrademarksoftheirowners.

    SafetymattersIn thewhole testprocess,please complywith common.safetypreventnorms. Ifyouuse the testerwithout thisusermanual, and the tester is damaged,DADI Telecomwont undertake any responsibility. Please be sure toobey the followingsafetynorms, lestcausebodily injuryortesterdamage.

  • Warning

    BatterychargingChargingthebatterymustusethechargerfromthemanufacturer.

    Youcantuseanyunauthorizedcharger,lestcausetesterdamage

    oraccident.

    BatteryreplacementPleaseusethemanufacturerconfiguredLibatteries.Youcant

    operatethetesterininflammableorexplosiveenvironment.Donot

    usethetesterinenvironmentwithinflammableorexplosiveliquid

    orsteam.Inthisenvironment,itwillbedangerouswithany

    electricalinstruments.

    OpenrearcoverUnlessyouwanttoreplacemodules,pleasedontopenrearcover

    orbottomcover.Thereplacemustbeoperatedbyformaltrained

    stuff.Thereishighvoltageinsomeareasinsidethetesterwhich

    willcausedangerousifitismishandled.

    LCDIftheLCDisdamagedandliquidoutflows,pleasedontinhaledit

    intomouthorsplashonskin.Iftheliquidissplashedintoeyeor

    mouth,pleaseimmediatelyrinsewithwaterandgotothehospital;

    iftheliquidissplashedonskinorclothes,pleasewipewithalcohol

    firstly,andthenwashwithsoapandwater.Inaddition,takecare,

    dontbescratchedbyglassfragments,donttouchtheborderof

    glassfragments.

  • CatalogueChapter1 General...............................................................1Chapter2 Inspection...........................................................3

    2.1 UnpacktheInstrument..........................................32.2 AccessoryandOption............................................32.3 PowerSupply.........................................................3

    Chapter3 TesterConfiguration............................................53.1 FrontView.............................................................5

    3.1.1 LEDs..............................................................63.1.2 Buttons.........................................................6

    3.2 TopPanel................................................................73.2.1 PowerAdapterPlug......................................73.2.2 E1UnbalancedPort......................................73.2.3 E1BalancedPort...........................................73.2.4 USBPort.......................................................7

    3.3 BottomDatacomPort............................................83.4 OtherAccessories..................................................8

    3.4.1 TouchPen.....................................................83.4.2 L9SelftestCable..........................................83.4.3 LoopbackTestPlug.......................................8

    Chapter4 Operation............................................................94.1 MainOperationInterface......................................94.2 E1Test..................................................................10

    4.2.1 E1TestConfiguration..................................11

  • 4.2.2 TimingTest.................................................124.2.3 TestandStatistics.......................................134.2.4 ViewData...................................................154.2.5 DefectInject...............................................164.2.6 VFMeasurementandSPEAKSlot...............174.2.7 DelayandAPSMeasurement.....................18

    4.3 Datacom(VSeriesPort)Test................................194.4 RecordsManagement..........................................204.5 SaveRecordstoPC...............................................214.6 SystemSettings....................................................214.7 SoftwareUpgrade................................................21

    Chapter5 MalfunctionAnalysisandSolution...................23Chapter6 MainTechnicalParameters...............................25

    6.1 E1BERtestparameter.........................................256.2 Datacomtestparameter......................................256.3 Others..................................................................26

    Informationaboutservice......................................................26

  • BER1530 1

    Chapter1 General

    BER1530DataTransmissionAnalyzer is the latestcompacthandheld

    tester. With large touch screen TFT color LCD, and builtin

    rechargeableLiionbattery. ItcanbeforE1/2Monlinemonitoringas

    wellasBER test from50b/s to2048kb/s,which is thenecessary tool

    fornetworkequipmentinstallation,troubleshootingandmaintenance.

    Functionz TX/RXoftheframeandunframedsignalz Supportthetermination,monitoringandbridgedz Bit,Code,FAS,CRCerrorinjectionanddetectionz Frame,Signaling,timeslotdataviewingz ITUTG.821/G.826/M2100erroranalysisz LoopbackdelayandSwitchingtimetest z Voice&FrequencyMeasurementz VSeriesPortTestz Testresulthistogramdisplayz Savethedetailsoferrorandalarmformorethan5000timesz TestrecordscanbetransferredtoPCbyUSBz Large capacity Liion battery guarantees more than 8 hours

    workingwithoutexternalpowersupply.

  • 2 BER1530

  • BER1530 3

    Chapter2 Inspection

    Its absolutely necessary for you to read inspections before unpack

    packageandcheck the instrumentor test. In thischapter,wewould

    liketohelpyouknowtheinitialworkstatusoftheinstrument.

    2.1 UnpacktheInstrument

    Beforeunpacking,please checkwhether there isanydamage in the

    cartonandthebag.Ifany,pleasesortallofthearticlesperthepacking

    list.

    In case that damaged bag or incomplete articles happen or the

    instrument cannot achieve function tests, please contact us

    immediately.

    2.2 AccessoryandOption

    Accessories to the instrument, please refer to the packing list. If

    receivedarticlesarenotthesamewithwhatisspecifiedinthepacking

    list,pleaseinformusimmediatelysoasnottomakeanyinfluenceon

    using.

    2.3 PowerSupply

    The instrument supports two power supplymodes,DC and battery,

    withabuiltin large capacity rechargeable lithiumbattery for8hour

    longconsecutiveoperationafterbeingfullycharged.

    When using external power supply, the battery will charge

    automaticallywiththebatterycapacityshownontherighttopcorner

  • 4 BER1530

    ofLCDoftheinstrumentatanymoment.

    WhenusingACpower,pleaseusetheACchargeraccompanied,orthe

    instrumentwillbedamaged.

    Precautions:

    Dontdisposewastedbatteryinwaterorfireforfearofbackfireorpollution.

    !Dontmake the twopolesof thebattery inshortcircuit for fearof

    dangers.

    !Dontmakebatteryclose to firesourceoruse inhigh temperature

    forfearofseverepersonalinjury.

  • BER1530 5

    Chapter3 TesterConfiguration

    3.1 FrontView

  • 6 BER1530

    3.1.1 LEDs

    SpecificationsoftheLEDsasfollows:

    IfthealarmorERRLEDContinuouslight,itshowsthatalarmorerror

    alwaysbefound;IftheLEDflashes,itshowsthatalarmorerrorhasbe

    foundbutwithoutconfirm.YoucanclicktheHisttocleanthehistory

    records.

    3.1.2 Buttons

    z Powerbutton:Press thebutton topoweron the tester.Whenthetesterisopen,ifcontinuouslyPressthebuttonfor1second

    theshutdowndialogueboxwillpopup,theuserclicksokto

    close the tester. If the tester cannotbe closedby the related

    system icon,Pressthepoweron/offbuttonforabout5second

    toshutoffthepowerofthetester.z Softkeyboardkey:pressittorecallsoftkeyboardonthedisplay

    bottomorcloseit.

    Name Meaning

    LOS LossofsignalAIS AISsignalhavebeenfoundLOF/LOP LossofframeorLossofpattern RDI RDIhavebeenfoundERR ErrorhavebeenfoundPower Testeratpoweronstatus

  • BER1530 7

    3.2 TopPanel

    3.2.1 PowerAdapterPlug

    Specificpoweradapter:Input50HzAC220V(Tolerancerangeis10%),

    outputDC8.4V.

    3.2.2 E1UnbalancedPort

    Unbalancedport(75)forE1output(TX).Unbalancedport(75/highimpedance)forE1input(RX).

    3.2.3 E1BalancedPort

    Balancedport(120)forE1output(TX:Pin4,5).Balancedport(120/highimpedance)forE1input(RX:Pin1,2).

    3.2.4 USBPort

    ThetestercanworkasanUSBdisk,afterconnectingtoPC;thestored

    recordcanbedownloaded.WecanupgradetesterssoftwareviatheUSBport.

    87654321

  • 8 BER1530

    3.3 BottomDatacomPort

    The datacom port is a DB25 multiprotocol interfacecan supportV.35V.36V.24X.21RS530 etc standard datacom interface viavariousCablewire.

    3.4 OtherAccessories

    3.4.1 TouchPen

    Touchpenisusedtoclickandinputonthescreen.Itisusuallyplaced

    inthebackofthetester.Pleasekeepitintotheoriginalpositionafter

    usetopreventloss.

    3.4.2 L9SelftestCable

    UsefortestingtheE1unbalancedports(RX&TX) tochecktheE1testfunction.

    3.4.3 LoopbackTestPlug

    Usefortestingthedatacomport,tocheckthedatacomtestfunction.

  • BER1530 9

    Chapter4 Operation

    4.1 MainOperationInterface

    Press the power button and the tester begins to work, DADI logo

    displaysonthescreen,thenoperationinterfacedisplaysasfollows:

    This bar includes battery volume and present time indication. Click

    present timeandadialogueboxwillpopup;youcanmodify time

    and date through this dialogue box. When battery icon turns red,

    pleasechargeimmediately.

    z functionsiconbarThis bar includes some functions icons, each represents a function,

    clicktheiconandenterthefunctioninterface.

    z ToolBar

    statusindicatorbar

    functionsiconbar

    toolbar

  • 10 BER1530

    This bar includes return iconreturn to upper operation

    interfaceand SIPiconopen/closesoftinputpanel.

    4.2 E1Test

    You can make an E1 test by L9 or RJ48 port on the top panel, as

    follows:

  • BER1530 11

    4.2.1 E1TestConfiguration

    Asabove,wehavepreset twousualmodes:outline testandonline

    test. Outline mode is default as BER test with unframe structure,

    termination and 2E151 pattern; online mode is default as high

    impedancemonitor, LIVE (frame BER) test, only frame structure is

    optional.ClickDetailfordetailedconfiguration.

    If the above setting can not meet test needs, you can choose

    customized mode, and click Detail button .The pop up detail

    dialogueboxlistsalloptionalitems,asfollows:

    Note:Allmodifications indetaildialogueboxwillbe available,until

    youclickOKinConfigdialoguebox.

  • 12 BER1530

    4.2.2 TimingTest

    As above, you can set single or continuous timing test. Auto test

    results will be automatically saved as a file that labeled with test

    finishingtime.YoucanviewautotestresultsatRecordsManagement.

  • BER1530 13

    4.2.3 TestandStatistics

    Asabove,clickstarttostarttest;asmalltesticonwilldisplayonthe

    statusbar forteststatus.ClickErrororRXCLK labeltoseemore

    realtimetestresults.

    ClickStat.buttonorclickStat. icon inE1 testmain interfaceand

    youcanviewtheerroranalysisaccordingtoG.821,G.826,M2100;and

    detailsoferrorsoralarms.

  • 14 BER1530

    Aneventdetails resolution is1 second, thecount iserrorsquantity

    within1secondoralarmsustainedtime.

  • BER1530 15

    4.2.4 ViewData

    Thetesterrealtimedisplaysreceivedtimeslotdata,FASwords,MFAS

    words,andsignaling.

  • 16 BER1530

    4.2.5 DefectInject

    Youcanselecttoinjectalarmsorerrors,andasmallinjecticonwill

    displayonthestatusbarfordefectinsertstatus.

  • BER1530 17

    4.2.6 VFMeasurementandSPEAKSlot

    VoiceFrequencyrangeis503950Hz,levelrangeis359dBm.

  • 18 BER1530

    4.2.7 DelayandAPSMeasurement

    As thedelayof a loopedback signal,before clicking test key, the

    signalmustbeloopbackatremote.Delaytestmaxtimeis3seconds.

  • BER1530 19

    ClickTestkey in10secondsbeforeswitch,andbesurethattester

    receives without any alarm and error. After switch, tester will

    calculateAPStimeaccordingtothesignaldefects.

    4.3 Datacom(VSeriesPort)Test

    Youcanmakeadatacom (v seriesport) testbyDB25multiprotocol

    portatthebottomoftester,asfollows:

    Exceptthetestconfiguration,otherfunctionsaresameastheE1test,

    thedatacomsignalconfigurationasfollows:

  • 20 BER1530

    4.4 RecordsManagement

    The test records are stored into internal flash chip with *.CSV file

    format, listed intheViewRecordwindow.Thedisplayofrecords is

    thesameasrealtimetest.

  • BER1530 21

    4.5 SaveRecordstoPC

    ThetestrecordsalsocanbecopiedtoPCviaUSBport.Whenthetest

    isconnectedtoPCbyMini_USBcable,itwillworkasanUSBdiskwith

    recordsinCSVfileformatsameasRecordsManagement.

    4.6 SystemSettings

    Timing set of backlight and automatic shutdown, factoryset and

    screencalibrationfunctionareprovided.Asfollows:

    Note:FormatDiskwillclearupallstoredtestrecords.

    4.7 SoftwareUpgrade

    ThetestercanupgradesoftwarethroughUSBport. Inordertoavoid

    errors, please contact us before you upgrade (contact on the back

    cover),confirmtherequirementandcompletetheupgradeunderour

    techniquesupport.

    Thedetailedupgradingstepsareasfollows:

    1ConnectthetesterUSBportwithPC2Pressthepowerandsoftkeyboardbuttonsatthesametime

  • 22 BER1530

    whenthetester isoff,thenthetesterscreenbecomeswhite,waiting

    forsoftwareupgrading.

    3OpenthesoftwareonPC,anditwillfindainstrumentautomatically(ontheActionscolumntherewillbeasimilardisplay 00 Internal

    Flash 256sectors..)asfollows:

    4Click button,selecttheupgradedocument.

    5Click button to startupgrade, at thismomentthe bottom scroll bar will display the progress. After complete the

    upgrade,click toexit.

  • BER1530 23

    Chapter5 MalfunctionAnalysisandSolution

    Faults Causes Solutions

    Tester can notopen

    LowbatteryTurn on after fullcharge

    Alarms orerrors existingalways

    Be injectingdefects

    Cancel error oralarminsertion

    LOF occurs onPCM30testing

    PCM31systemisSet the tester toPCM31

    LOS existingalways

    1.NoInputsignal 2.120portisselected

    1.Check the inputcable2.Select75port

    Errors appearall the time inthe onlinemonitoring.

    Test type selectedasBERMode

    Select the testtypeasLiveMode

    UnknownfaultsThe confusion ofsettings

    Load defaultsetting

  • 24 BER1530

  • BER1530 25

    Chapter6 MainTechnicalParameters

    6.1 E1BERtestparameter

    z internalclock2048KHz5ppmz testcodeHDB3/AMIz framingPCM30/PCM30CRC/PCM31/PCM31CRCunframez testpatternPRBS2n1n=6,9,11,15,20,23,all0all1

    101016bitsusertestpatternsz errorinjectiontypebitCodeCRC4FASz errorinjectionmodesinglemultipleRate110nn=34

    567z TX clockRXclockinternaloscillatorz alarmdetectionLOSAISLOFRDILOCz TXclockoffset125+125ppmz audiofrequencymeasurementsz frequencyrange50Hz3950Hzresolution1Hzz levelrange+3dBm59dBmresolution1dBmz TXportunbalancedL975balanced120z RXportunbalancedL975balanced120monitor>2K

    6.2 Datacomtestparameter

    z bitrate50bit/s2048kbit/sz codebinarycodestreamz testpatternPRBS2n1n=6,9,11,15,20,23,all0all1

    101016bitsusertestpatterns

  • 26 BER1530

    z errorinjectionsingle,Rate110nn=34567z interface standardV.24/RS232V.35V.36/RS449X.21

    RS530

    6.3 Others

    z 320240TFTcolorLCD,touchscreenz embeddedoperationsystem,Iconinterfacez 5000recordscanbesaved,workasanUdisktoPC,z Storagespace: 2MBytez builtin7.4V1500mAhLibatterymaxsystempower2.5Wz batteryoperationtimeabout8hoursz batterychargingtime:about6hoursz temperaturerange

    nominalrangeofuse10+50storagerange40+70

    z size146mm87mm50mmz weight0.6Kg

    Informationaboutservice

    CompanyWebsite:http://www.lzdd.com

    BusinessLine:(086)1082511182

    TechnicalSupportLine:(086)1082867177

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False

    /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles false /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice