1

Page 3: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

2 BICC CABLES

INDEX

1. BICC Cables Background

1.1 History

1.2 Product Range

1.3 Product Quality

1.4 Certifications

1.5 Product Code

1.6 Technical Advisory Service

2. General Technical Information

2.1 Current Carrying Capacity & Voltage Drop

2.2 Current Rating Factors

2.3 Short Circuit Ratings

2.4 Installation

3. Control Cables

3.0 Data Tables for control cables

This catalogue includes detailes about our product range of control & instrument cables providing our customers with general technical infromation and approximate dimensions and weights for the finished cables.

6

6

7

8

10

12

16

19

21

22

26

Page 4: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

3

4. Instrument Cables

4.0 Data Tables for instrument cables

5. Building & Earthing Wires

5.0 Data Tables for earthing & building wires

6. Fire Resistance Control & Instrument Cables

6.0 Data Tables for Fire Resistance Control & Instrument Cables

7. Glossary

54

82

88

124

Page 5: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

4 BICC CABLES

1.0 BICC Cables Background

Page 6: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

5

1.0 BICC Cables Background

Page 7: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

6 BICC CABLES

Incorporation of BICC as a joint venture between BICC Cables and Electro George Group.

Acquisition of 100% shares of BICC by consortium of financial investors led by Karnak Investments Ltd.

Acquisition of 100% shares of BICC shares by General Cable Coporation.

Acquisition of 100% shares of BICC shares by Amana International Holding.

1.1 History

1.2 Product Range

The company was originally established in 1996 under the name of BICC Egypt as a joint venture between BICC Cables UK and Egyptian investors. It was the only multinational cable manufacturer in Egypt. In September 2010, General Cable, a Fortune of 500 company and the leading manufacturer of wires and cables with 38 production facilities around the world, acquired BICC and rebranded itto General Cable.In May 2016, as part of its strategy to refocus on the American and European markets, General Cable sold the factory to a group of investors. The company gained its original brand name BICC Cables.

-Instrument Cables-Fire resistance & Fire Alarm Cables-Overhead Transmission Lines

We are proud of what we have achieved during last 3 years under the umbrella of our current management(AMANA HOLDING) as we could supply our cables in the most vital projects in country in many sectors such as contracting, industrial , tourism , electrical power stations, water treatment stations , airports,………etc.Also, we acquired new machines seeking increase our production capacity and improving ourproduct quality.There is still much work to be done and we are seeking in the current time to establish new production line so that we can meet our customer needs and satisfaction.

-LV Power Cables-Control Cables -Building Wires

This publication covers our range of production for Control & Instrument Cables.

BICC Cables Scope of production includes as follows:

1.0 BICC Cables Background

Page 8: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

7

1.3 Product QualityQuality Control in all steps of manufacturing is one of the priorities of BICC cables, keen to provide its customers with the best quality and meeting deadlines. All our facilities operate under the highest ISO:9001:2015 Standards.We use the latest measuring devices (made in EU) for an effective application of quality standards.Also, we are using only tried and tested materials and processes in full compliance with all the relevant British and International standards. We are very keen to purchase raw materials from the most accredit-ed suppliers either from local market or from abroad.

Page 9: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

8 BICC CABLES

1.4 Certifications• Quality Management System ISO 9001:2015

• KEMA Approval

• Health and Safety OHSAS 18001

1.0 BICC Cables Background

Page 10: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

9

• BASEC Approval

Page 11: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

10 BICC CABLES

Product Code For Control Cables

NO. OF CORES

THE CONDUCTORMATERIAL

THE OUTER SHEATH MATERIAL

THE ARMOURINGMATERIAL

SCREENINGMATERIAL

THE BEDDINGMATERIAL

THE INSULATIONMATERIAL

TAPE

01C Single Core02C Two Cores03C Three Cores

P Polyvinyl Chloride (PVC)X Cross Linked - Polyethylene (XLPE)L Low Smoke Zero Halogen (LSOH)

P Polyvinyl Chloride (PVC)L Low Smoke Zero Halogen (LSOH)

P Polyvinyl Chloride (PVC)L Low Smoke Zero Halogen (LSOH)

THE CONDUCTORCROSS SECTION

AREA (MM2)

C Copper

W Wire Armoured

CT Copper Tape

M Mica Tape

1.5 Product Code

1.0 BICC Cables Background

Page 12: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

11

Product Code For Instrumentation Cables

NO.OF PAIRS/TRAIDS

01P 1 Pair02P 2 Pairs01T 1 Traid

THE CONDUCTORCROSS SECTION

AREA (MM2)

THE CONDUCTORMATERIALC Copper

THE OUTER SHEATH MATERIAL

P Polyvinyl Chloride (PVC)L Low Smoke Zero Halogen (LSOH)

THE ARMOURINGMATERIAL

T Tape ArmouredW Wire Armoured

THE BEDDINGMATERIAL

IS : Individual Shielding

P Polyvinyl Chloride (PVC)L Low Smoke Zero Halogen (LSOH)

THE INSULATIONMATERIAL

P Polyvinyl Chloride (PVC)X Cross Linked - Polyethylene (XLPE)L Low Smoke Zero Halogen (LSOH)

TAPE

M Mica Tape

OS : Overall Shielding

Page 13: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

12 BICC CABLES

Specialist advice on all matters concerning control & instrument cables is available from BICC Cables sales team or direct from:

BICC CABLES S.A.E, FactoryIndustrial Zone, Abu Rawash Km 28 Cairo Alexandria Desert Road Giza, EgyptTel.: (202) 3539 0251,2,3,4Fax: (202) 3539 0255,6E-mail: [email protected]

1.6 Technical Advisory Service

Head Office34 Block A 1st District Services Center New Cairo,EgyptTel: (202) 22471677 / 22471699Fax.: (202) 22472011Website: www.bicccables.comE-mail: [email protected]

1.0 BICC Cables Background

Page 14: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

13

Our products are designed & constructed to be hazard free under the prescribed conditions of use.

Page 15: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

14 BICC CABLES

2.0 General Technical Information

Page 16: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

15

2.0 General Technical Information

Page 17: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

16 BICC CABLES

2.0 General Technical Information

2.1 Current Carrying Capacity & Voltage DropCurrent carrying capacity is the maximum current that can be continuously carried without exceeding its temperature rating. It is also known as ampacity.The effect of resistance to current flow is heating and this is dependent upon the size of the conductor where increasing the conductor size increases the current carrying capacity.Also, current is affected with insulation material around the conductor where the higher the temperature resistance of the insulating material, the higher the ampacity. A 90°C rated insulation (familiar for XLPE insulation) will have a higher current capacity than a 70°C rated insulation (familiar for PVC insulation).Also, current rating is affected by installation environment & its temperature. When current flows in a cable conductor there is a voltage drop between the ends of the conductor which is the product of the current and the impedance.The following tables indicate current rating and voltage drop for conductor sizesfrom 1 mm2 up to 10 mm2 For cables installed in air and laid in ground for 600/1000 V PVC & XLPE insulated cables.

Page 18: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

17

Current Rating & Voltage Drop for PVC insulted Cables (installed in Air)

Current Rating & Voltage Drop for XLPE insulted Cables (installed in Air)

Conductor NominalArea (mm2 )

Two Cores Three and Four Cores

Current Rating in Free air at 40oC (Amp.)

Voltage Drop (mV/A/m)

Current Rating in Free air at 40oC (Amp.)

Voltage Drop (mV/A/m)

1.0 15 35 12 30

1.5 19 29 17 25

2.0 23 25 19 20

2.5 27 18 23 15

3.0 30 16 25 13

4.0 36 11 30 9.5

6.0 46 7.3 39 6.4

10.0 63 4.4 54 3.8

Conductor NominalArea (mm2 )

Two Cores Three and Four Cores

Current Rating in Free air at 40oC (Amp.)

Voltage Drop (mV/A/m)

Current Rating in Free air at 40oC (Amp.)

Voltage Drop (mV/A/m)

1.0 22 37 18 32

1.5 26 31 23 27

2.0 31 25 26 22

2.5 35 19 30 16

3.0 39 17 34 14

4.0 47 12 40 10

6.0 60 7.9 51 6.8

10.0 82 4.7 71 4.0

For cables installed in free air (Reference method 11 on cable tray or method 13 in free air– IEE wiring regulations 17th edition) & ambient temperature 40°C.

- Cables installed in Free Air

Page 19: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

18 BICC CABLES

2.0 General Technical Information

- Cables laid in Ground & installed in single way ducts

Current ratings are based on Ground temperature 35°C, soil thermal resistivity 1.2 °C m/W, depth of laying 0.5 Mt and all circuits are thermally independent.Currents in ducts are for 100 mm diameter single way ducts.

Current Rating & Voltage Drop for PVC insulted Cables (Cables laid in Ground & Duct)

Current Rating & Voltage Drop for XLPE insulted Cables (Cables laid in Ground & Duct)

Conductor Nominal

Area (mm2)

Two Cores Three and Four Cores

Current Rating (Amp.)Voltage Drop

(mV/A/m)

Current Rating (Amp.)Voltage Drop

(mV/A/m)In Ground at (35oC)

In Duct at (35oC)

In Ground at (35oC)

In Duct at (35oC)

1.0 19 16 35 16 14 30

1.5 26 21 29 22 18 25

2.0 29 24 25 25 20 20

2.5 33 27 18 28 23 15

3.0 36 30 16 31 26 13

4.0 44 36 11 38 30 9.5

6.0 55 46 7.3 47 38 6.4

10.0 74 61 4.4 62 51 3.8

Conductor Nominal

Area (mm2)

Two Cores Three and Four Cores

Current Rating (Amp.)Voltage Drop

(mV/A/m)

Current Rating (Amp.)Voltage Drop

(mV/A/m)In Ground at (35oC)

In Duct at (35oC)

In Ground at (35oC)

In Duct at (35oC)

1.0 26 22 37 22 18 32

1.5 33 27 31 28 22 27

2.0 37 31 25 32 26 22

2.5 42 35 19 36 29 16

3.0 46 39 17 40 32 14

4.0 56 46 12 47 39 10

6.0 70 58 7.9 59 48 6.8

10.0 94 77 4.7 79 65 4

Page 20: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

19

Current Rating for Non Sheathed (450/750 V) Single Core Cables

Current Rating Factors for Ambient Air Temperature (Cables installed in Air)

Current Rating Factors for Ground Temperature (Cables laid direct or in ground)

Conductor Area (mm2)Current Rating (Amp.)

In Free Air In Pipes

1.0 13 10

1.5 16 13

2.0 18 14

2.5 25 20

3.0 27 21

4.0 33 23

6.0 39 28

10.0 58 40

2.2 Current Rating FactorsCurrent carrying capacity is affected by installation environment and several factors such as ambient or ground temperature, change in depth of laying , soil thermal resistivity or number of grouping of cables.The current rating must be multiplied by relevant rating factors as in the below tables.

Ambient Air Tem-perature 25°C 30°C 35°C 40°C 45°C 50°C 55°C

Rating Factor

PVC Insulation 1.14 1.10 1.05 1.0 0.96 0.90 0.84

XLPE Insulation 1.22 1.15 1.08 1.0 0.91 0.80 0.70

Ground Temperature 15°C 20°C 25°C 30°C 35°C 40°C 45°C

Rating Factor

PVC Insulation 1.16 1.13 1.08 1.03 1.00 0.95 0.88

Page 21: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

20 BICC CABLES

2.0 General Technical Information

Current Rating Factors for Depth Of Laying (For Cables laid in Ground)

Current Rating Factors for Variation in Soil Resistivity(For Cables laid in Ground or Duct)

Current Rating Factors for Number of cables (circuits) in group for cables in horizontal formation

Depth Of Laying (Mt)Multicore Cable

Direct ground In single way ducts

0.5 1.0 1.0

0.6 0.99 0.99

0.8 0.97 0.97

1.00 0.95 0.96

1.25 0.94 0.95

Type of InstallationSoil Thermal Resistivity in o Cm/W

0.8 0.9 1 1.5 2 2.5

Multicore cables laid directly in ground 1.09 1.06 1.04 0.93 0.84 0.77

Multicore cables installed in single way ducts 1.03 1.02 1.02 0.97 0.91 0.87

Method of installation No. of cables in group

Spacing between cable centers

Touching 0.15 Mt. 0.3 Mt. 0.45 Mt. 0.6 Mt.

Cables direct in Ground

2 0.81 0.87 0.91 0.93 0.94

3 0.70 0.78 0.84 0.87 0.90

4 0.63 0.74 0.81 0.86 0.89

5 0.59 0.70 0.78 0.83 0.87

6 0.55 0.67 0.76 0.82 0.86

Cables in single way Ducts

2 0.90 0.93 0.95 0.96

3 0.82 0.87 0.90 0.93

4 0.78 0.85 0.89 0.91

5 0.76 0.82 0.87 0.90

6 0.72 0.81 0.86 0.90

Page 22: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

21

2.3 Short Circuit RatingsWhen cables are subjected to temperature higher than those permissible for continuous operation they may suffer damage. Therefore, in installation when there is possibility of the cables being overloaded by mistake or by accident , cables should be selected having regard to the characteristics of the device used or protection against excess current so that the effects of overloading are limited to a degree tolerable to or a relatively short period of operation.

XLPE Insulated CablesThe values of fault current given in the graph are based on the cable being fully loaded at the start of the short circuit (conductor temperature 90°C) and a final conductor temperature of 250°C. It should be ensured that the accessories associated with the cable are also capable of operation at these values of fault current and temperature.

PVC Insulated CablesThe values of fault current given in the graph are based on the cable being fully loaded at the start of the short circuit (conductor temperature 70°C) and a final conductor temperature of 160 oC.

Page 23: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

22 BICC CABLES

2.4 Installation All cables in this publication can be used for outdoor applications but some reservations are necessary concerning cables without metal sheath for direct burial such as :- Unarmoured cables are not recommended for laying directly in the ground.- Cables laid directly in the ground, particularly in sustained wet conditions shouldhave extruded bedding.- For installations where there is water-logging or where it is likely to occur, advice should be obtained from our technical department. It may be desirable to recommend an alternative type of outer sheath for the cable (e.g. MDPE).

Also, bending radius shall be considered during installation where cables shall not be bent in radius smaller than that recommended noting that minimum bending radius as follows:

2.0 General Technical Information

Cable support shall be taken into consideration as in the below table

Recommended Support spacing

Recommended Minimum Bending Radius

Overall cable diametermm

Support spacing

Horizontal(mm)

Vertical(mm)

Below 15 350 450

15 to less than 20 400 550

20 to less than 40 450 600

40 to less than 60 700 900

Cable Type Minimum Bending Radius

Control or instrument cable in PVC outer sheath 10 Times of Cable Nominal External Diameter

Control or instrument cable in LSOH outer sheath 15 Times of Cable Nominal External Diameter

Page 24: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

23

A world power in cable supply

Page 25: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

24 BICC CABLES

3.0 Control Cables

Page 26: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

25

3.0 Control Cables

Page 27: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

26 BICC CABLES

3.0 Control Cables

Application

Construction

Design Specification Standards

Control Cables are commonly used as interconnecting cables for control devices , e.g. on machine tools, conveyor or assembly lines, transporting equipment, production lines and construction of industrial plants.

1. Conductor Copper (or Tinned Copper) In different flexibility degrees- Solid Copper: Class 1- Stranded Copper: Class 2- Flexible Copper: Class 5

2. Insulation- Cross Linked Polyethylene (XLPE) Maximum conductor temperature is 90°C- Polyvinyl Chloride (PVC) Maximum conductor temperature is 70°C & 105°C for fire alarm cables- Low Smoke Zero Halogen (LSOH) Maximum conductor temperature is 90°C

3. Bedding- Polyvinyl Chloride (PVC)- Low Smoke Zero Halogen (LSOH) (For applications where flame spread, minimal smoke and toxic gases emission are critical)

4. Armour / Screen- Armour : Galvanized Steel Wire Armour (GSWA) One layer of round wires is applied over the bedding for mechanical protection of cable- Screen: Copper Tape Screen (CTS) Screen of copper tape can be applied helically over the bedding

5. Outer Sheath- Polyvinyl Chloride (PVC)- Low Smoke Zero Halogen (LSOH)

Standard specification applied to cable

Standard specification applied to conductor Spread of Flame

principle to IEC 60502-1

IEC 60228

Flame retardant as per IEC 60332-1

Page 28: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

27

Sizes

Core Identification

Options Available

Rated Voltage

This publication covers the following range

- No. of cores : From 2 cores up to 48 cores - Conductor area : from 1 mm2 up to 10 mm2

Two cores : Red , Black Three cores : Red , Yellow , Blue Four cores : Red , Yellow , Blue , Black Five cores : Red , Yellow , Blue , Black , Y/GMore than 5 cores : Black with white numbers

Other special colors are available upon request.

Sizes :All sizes are available upon request.

Material :Where necessary, special features can be incorporated into the cable enabling it to have- Improved fire performance- Low smoke and fume (Halogen free )- Termite resistance- Resistance to attack from oils, solvents or corrosive chemicals

For environment where emissions of smoke and toxic gases are critical , insulation , bedding and outer sheath material can be : Low Smoke Zero Halogen which has abbreviations of LS0H , LSOH & LSZH(the 3 abbreviations are the same material) with no halogen content and controlled emission of smokeAlso, it is the same as Low Smoke Halogen Free (LSHF).

Note: Values in the following tables are approximate and subject to manufacturing tolerance.

600/1000 V

Page 29: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

28 BICC CABLES

Control Cables, Non Armoured,PVC insulatedApplicationControl cables are used as interconnecting cables for control devicesfor outdoor and indoor installation.

Construction

1. ConductorStranded Copper class 2

2. InsulationPolyvinyl Chloride (PVC)

3. SheathPolyvinyl Chloride (PVC)

3.0 Control Cables

Page 30: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

29

Control Cables, Non Armoured, PVC Insulated

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.0 mm2

02c001CP00P 2 7/0.43 0.8 8.9 107

03c001CP00P 3 7/0.43 0.8 9.4 182

04c001CP00P 4 7/0.43 0.8 10.1 212

07c001CP00P 7 7/0.43 0.8 12.3 293

12c001CP00P 12 7/0.43 0.8 15.6 434

19c001CP00P 19 7/0.43 0.8 18.0 596

27c001CP00P 27 7/0.43 0.8 21.3 785

37c001CP00P 37 7/0.43 0.8 23.7 997

48c001CP00P 48 7/0.43 0.8 27.0 1255

Conductor 1.5 mm2

02c001.5CP00P 2 7/0.53 0.8 9.4 206

03c001.5CP00P 3 7/0.53 0.8 9.9 215

04c001.5CP00P 4 7/0.53 0.8 10.7 244

07c001.5CP00P 7 7/0.53 0.8 13.0 345

12c001.5CP00P 12 7/0.53 0.8 16.6 521

19c001.5CP00P 19 7/0.53 0.8 19.2 729

27c001.5CP00P 27 7/0.53 0.8 22.7 969

37c001.5CP00P 37 7/0.53 0.8 25.3 1243

48c001.5CP00P 48 7/0.53 0.8 29.1 1573

Conductor 2.0 mm2

02c002C0P00P 2 7/0.60 0.8 9.9 230

03c002C0P00P 3 7/0.60 0.8 10.4 240

04c002C0P00P 4 7/0.60 0.8 11.3 278

07c002C0P00P 7 7/0.60 0.8 13.8 399

12c002C0P00P 12 7/0.60 0.8 17.6 607

19c002C0P00P 19 7/0.60 0.8 20.5 857

27c002C0P00P 27 7/0.60 0.8 24.3 1147

37c002C0P00P 37 7/0.60 0.8 27.2 1480

48c002C0P00P 48 7/0.60 0.8 31.4 1899

Page 31: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

30 BICC CABLES

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)Conductor 2.5 mm2

02c02.5C0P00P 2 7/0.67 0.8 10.2 250

03c02.5C0P00P 3 7/0.67 0.8 10.7 258

04c02.5C0P00P 4 7/0.67 0.8 11.6 308

07c02.5C0P00P 7 7/0.67 0.8 14.1 447

12c02.5C0P00P 12 7/0.67 0.8 18.2 685

19c02.5C0P00P 19 7/0.67 0.8 21.1 976

27c02.5C0P00P 27 7/0.67 0.8 25.1 1312

37c02.5C0P00P 37 7/0.67 0.8 28.3 1702

48c02.5C0P00P 48 7/0.67 0.8 32.5 2205

Conductor 3 mm2

02c003C0P00P 2 7/0.74 0.8 10.6 280

03c003C0P00P 3 7/0.74 0.8 11.2 295

04c003C0P00P 4 7/0.74 0.8 12.2 336

07c003C0P00P 7 7/0.74 0.8 14.8 494

12c003C0P00P 12 7/0.74 0.8 19.1 763

19c003C0P00P 19 7/0.74 0.8 22.2 1095

27c003C0P00P 27 7/0.74 0.8 26.5 1478

37c003C0P00P 37 7/0.74 0.8 29.8 1946

Conductor 4 mm2

02c004C0P00P 2 7/0.84 1.0 12.2 334

03c004C0P00P 3 7/0.84 1.0 12.9 350

04c004C0P00P 4 7/0.84 1.0 14.0 424

07c004C0P00P 7 7/0.84 1.0 17.1 633

12c004C0P00P 12 7/0.84 1.0 22.3 990

19c004C0P00P 19 7/0.84 1.0 26.1 1435

27c004C0P00P 27 7/0.84 1.0 31.7 1971

37c004C0P00P 37 7/0.84 1.0 35.7 2619

Follow: Control Cables, Non Armoured, PVC Insulated

3.0 Control Cables

Page 32: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

31

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 6 mm2

02c006C0P00P 2 7/1.04 1.0 13.2 396

03c006C0P00P 3 7/1.04 1.0 14.0 429

04c006C0P00P 4 7/1.04 1.0 15.3 527

Conductor 10 mm2

02c010C0P00P 2 7/1.36 1.0 15.3 513

03c010C0P00P 3 7/1.36 1.0 16.2 583

04c010C0P00P 4 7/1.36 1.0 17.7 725

Follow: Control Cables, Non Armoured, PVC Insulated

Page 33: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

32 BICC CABLES

Control Cables, Non Armoured,XLPE insulated ApplicationControl cables are used as interconnecting cables for control devices for outdoor and indoor installations.

Construction

1. ConductorStranded Copper class 2

2. InsulationCross Linked Polyethylene (XLPE)

3. SheathPolyvinyl Chloride (PVC)

3.0 Control Cables

Page 34: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

33

Control Cables, Non Armoured, XLPE Insulated

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.0 mm2

02c001C0X00P 2 7/0.43 0.7 8.5 160

03c001C0X00P 3 7/0.43 0.7 8.9 175

04c001C0X00P 4 7/0.43 0.7 9.6 184

07c001C0X00P 7 7/0.43 0.7 11.7 248

12c001C0X00P 12 7/0.43 0.7 14.8 359

19c001C0X00P 19 7/0.43 0.7 17.0 483

27c001C0X00P 27 7/0.43 0.7 20.1 628

37c001C0X00P 37 7/0.43 0.7 22.3 784

48c001C0X00P 48 7/0.43 0.7 25.4 982

Conductor 1.5 mm2

02c01.5C0X00P 2 7/0.53 0.7 9.0 182

03c01.5C0X00P 3 7/0.53 0.7 9.4 195

04c01.5C0X00P 4 7/0.53 0.7 10.2 213

07c01.5C0X00P 7 7/0.53 0.7 12.4 295

12c01.5C0X00P 12 7/0.53 0.7 15.7 438

19c01.5C0X00P 19 7/0.53 0.7 18.2 602

27c01.5C0X00P 27 7/0.53 0.7 21.5 792

37c01.5C0X00P 37 7/0.53 0.7 23.9 1006

48c01.5C0X00P 48 7/0.53 0.7 27.3 1266

Conductor 2.0 mm2

02c002C0X00P 2 7/0.60 0.7 9.5 209

03c002C0X00P 3 7/0.60 0.7 10.0 217

04c002C0X00P 4 7/0.60 0.7 10.8 245

07c002C0X00P 7 7/0.60 0.7 13.2 345

12c002C0X00P 12 7/0.60 0.7 16.8 518

19c002C0X00P 19 7/0.60 0.7 19.5 721

27c002C0X00P 27 7/0.60 0.7 23.1 955

37c002C0X00P 37 7/0.60 0.7 25.6 1224

48c002C0X00P 48 7/0.60 0.7 29.6 1550

Page 35: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

34 BICC CABLES

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 2.5 mm2

02c02.5C0X00P 2 7/0.67 0.7 9.8 230

03c02.5C0X00P 3 7/0.67 0.7 10.3 240

04c02.5C0X00P 4 7/0.67 0.7 11.1 273

07c02.5C0X00P 7 7/0.67 0.7 13.5 390

12c02.5C0X00P 12 7/0.67 0.7 17.3 590

19c02.5C0X00P 19 7/0.67 0.7 20.1 830

27c02.5C0X00P 27 7/0.67 0.7 23.9 1116

37c02.5C0X00P 37 7/0.67 0.7 26.7 1435

48c02.5C0X00P 48 7/0.67 0.7 30.6 1820

Conductor 3 mm2

02c003C0X00P 2 7/0.74 0.7 10.2 250

03c003C0X00P 3 7/0.74 0.7 10.8 270

04c003C0X00P 4 7/0.74 0.7 11.7 300

07c003C0X00P 7 7/0.74 0.7 14.2 433

12c003C0X00P 12 7/0.74 0.7 18.3 662

19c003C0X00P 19 7/0.74 0.7 21.2 940

27c003C0X00P 27 7/0.74 0.7 25.2 1262

37c003C0X00P 37 7/0.74 0.7 28.4 1634

Conductor 4 mm2

02c004C0X00P 2 7/0.84 0.7 11.0 279

03c004C0X00P 3 7/0.84 0.7 11.6 290

04c004C0X00P 4 7/0.84 0.7 12.6 348

07c004C0X00P 7 7/0.84 0.7 15.3 511

12c004C0X00P 12 7/0.84 0.7 19.8 790

19c004C0X00P 19 7/0.84 0.7 23.1 1135

27c004C0X00P 27 7/0.84 0.7 27.8 1529

37c004C0X00P 37 7/0.84 0.7 31.3 2012

Follow: Control Cables, Non Armoured, XLPE Insulated

3.0 Control Cables

Page 36: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

35

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 6 mm2

02c006C0X00P 2 7/1.04 0.7 12.0 342

03c006C0X00P 3 7/1.04 0.7 12.7 364

04c006C0X00P 4 7/1.04 0.7 13.9 444

Conductor 10 mm2

02c010C0X00P 2 7/1.36 0.7 14.1 453

03c010C0X00P 3 7/1.36 0.7 14.9 508

04c010C0X00P 4 7/1.36 0.7 16.2 630

Follow: Control Cables, Non Armoured, XLPE Insulated

Page 37: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

36 BICC CABLES

Control Cables, Armoured, PVC insulated ApplicationControl cables are used as interconnecting cables for control devices and armoured cablesin environment where mechanical damage is expected to occur.

Construction

1. ConductorStranded Copper class 2

2. InsulationPolyvinyl Chloride (PVC)

3. Armour Galvanized Round Steel Wire (GSWA)

4. SheathPolyvinyl Chloride (PVC)

3.0 Control Cables

Page 38: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

37

Control Cables, Armoured, PVC Insulated

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.0 mm2

02c001C0PPWP 2 7/0.43 0.8 0.9 13.0 320

03c001C0PPWP 3 7/0.43 0.8 0.9 13.5 400

04c001C0PPWP 4 7/0.43 0.8 0.9 14.2 447

07c001C0PPWP 7 7/0.43 0.8 1.25 17.1 563

12c001C0PPWP 12 7/0.43 0.8 1.25 20.4 877

19c001C0PPWP 19 7/0.43 0.8 1.6 23.5 1100

27c001C0PPWP 27 7/0.43 0.8 1.6 26.8 1546

37c001C0PPWP 37 7/0.43 0.8 1.6 29.4 1872

48c001C0PPWP 48 7/0.43 0.8 2.0 33.7 2260

Conductor 1.5 mm2

02c01.5C0PPWP 2 7/0.53 0.8 0.9 13.5 425

03c01.5C0PPWP 3 7/0.53 0.8 0.9 14.0 439

04c01.5C0PPWP 4 7/0.53 0.8 0.9 14.8 495

07c01.5C0PPWP 7 7/0.53 0.8 1.25 17.8 722

12c01.5C0PPWP 12 7/0.53 0.8 1.6 22.1 1001

19c01.5C0PPWP 19 7/0.53 0.8 1.6 24.7 1416

27c01.5C0PPWP 27 7/0.53 0.8 1.6 28.4 1789

37c01.5C0PPWP 37 7/0.53 0.8 1.6 31.2 2195

48c01.5C0PPWP 48 7/0.53 0.8 2.0 35.8 2918

Conductor 2.0 mm2

02c002C0PPWP 2 7/0.60 0.8 0.9 14.0 451

03c002C0PPWP 3 7/0.60 0.8 0.9 14.5 476

04c002C0PPWP 4 7/0.60 0.8 0.9 15.4 538

07c002C0PPWP 7 7/0.60 0.8 1.25 18.6 794

12c002C0PPWP 12 7/0.60 0.8 1.6 23.1 1225

19c002C0PPWP 19 7/0.60 0.8 1.6 26.0 1578

27c002C0PPWP 27 7/0.60 0.8 1.6 30.3 2034

37c002C0PPWP 37 7/0.60 0.8 1.6 34.1 2504

48c002C0PPWP 48 7/0.60 0.8 2.0 38.1 3352

Page 39: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

38 BICC CABLES

Product Code No. of CoresStrand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 2.5 mm2

02c02.5C0PPWP 2 7/0.67 0.8 0.9 14.3 481

03c02.5C0PPWP 3 7/0.67 0.8 0.9 14.8 511

04c02.5C0PPWP 4 7/0.67 0.8 1.25 16.4 656

07c02.5C0PPWP 7 7/0.67 0.8 1.25 18.9 863

12c02.5C0PPWP 12 7/0.67 0.8 1.6 23.7 1346

19c02.5C0PPWP 19 7/0.67 0.8 1.6 26.6 1749

27c02.5C0PPWP 27 7/0.67 0.8 1.6 31.0 2253

37c02.5C0PPWP 37 7/0.67 0.8 2.0 35.0 3016

48c02.5C0PPWP 48 7/0.67 0.8 2.0 39.2 3746

Conductor 3 mm2

02c003C0PPWP 2 7/0.74 0.8 0.9 14.7 504

03c003C0PPWP 3 7/0.74 0.8 0.9 15.3 540

04c003C0PPWP 4 7/0.74 0.8 1.25 17.0 696

07c003C0PPWP 7 7/0.74 0.8 1.25 19.6 921

12c003C0PPWP 12 7/0.74 0.8 1.6 24.6 1442

19c003C0PPWP 19 7/0.74 0.8 1.6 27.9 1887

27c003C0PPWP 27 7/0.74 0.8 1.6 32.4 2500

37c003C0PPWP 37 7/0.74 0.8 2.0 36.5 3400

Conductor 4 mm2

02c004C0PPWP 2 7/0.84 1.0 1.25 17.0 672

03c004C0PPWP 3 7/0.84 1.0 1.25 17.7 730

04c004C0PPWP 4 7/0.84 1.0 1.25 18.8 838

07c004C0PPWP 7 7/0.84 1.0 1.25 21.9 1238

12c004C0PPWP 12 7/0.84 1.0 1.6 27.8 1776

19c004C0PPWP 19 7/0.84 1.0 1.6 32.0 2386

27c004C0PPWP 27 7/0.84 1.0 2.0 38.4 3462

37c004C0PPWP 37 7/0.84 1.0 2.0 42.4 4270

Follow: Control Cables, Armoured, PVC Insulated

3.0 Control Cables

Page 40: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

39

Product Code No. of CoresStrand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 6 mm2

02c006C0PPWP 2 7/1.04 1.0 1.25 18.0 764

03c006C0PPWP 3 7/1.04 1.0 1.25 18.8 843

04c006C0PPWP 4 7/1.04 1.0 1.25 20.6 974

Conductor 10 mm2

02c010C0PPWP 2 7/1.36 1.0 1.25 20.1 922

03c010C0PPWP 3 7/1.36 1.0 1.25 21.0 1040

04c010C0PPWP 4 7/1.36 1.0 1.6 23.4 1344

Follow: Control Cables, Armoured, PVC Insulated

Page 41: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

40 BICC CABLES

Control Cables, Armoured, XLPE insulated ApplicationControl cables are used as interconnecting cables for control devices and armoured cablesin environment where mechanical damage is expected to occur.

Construction

1. ConductorStranded Copper class 2

2. InsulationCross Linked Polyethylene (XLPE)

3. Armour Galvanized Round Steel Wire (GSWA)

4. SheathPolyvinyl Chloride (PVC)

3.0 Control Cables

Page 42: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

41

Control Cables, Armoured, XLPE Insulated

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.0 mm2

02c001C0XPWP 2 7/0.43 0.7 0.9 12.6 359

03c001C0XPWP 3 7/0.43 0.7 0.9 13.0 369

04c001C0XPWP 4 7/0.43 0.7 0.9 13.7 406

07c001C0XPWP 7 7/0.43 0.7 1.25 16.5 573

12c001C0XPWP 12 7/0.43 0.7 1.25 19.6 775

19c001C0XPWP 19 7/0.43 0.7 1.6 22.5 1070

27c001C0XPWP 27 7/0.43 0.7 1.6 25.6 1330

37c001C0XPWP 37 7/0.43 0.7 1.6 28.0 1580

48c001C0XPWP 48 7/0.43 0.7 1.6 31.3 1905

Conductor 1.5 mm2

02c01.5C0XPWP 2 7/0.53 0.7 0.9 13.1 401

03c01.5C0XPWP 3 7/0.53 0.7 0.9 13.5 410

04c01.5C0XPWP 4 7/0.53 0.7 0.9 14.3 458

07c01.5C0XPWP 7 7/0.53 0.7 1.25 17.2 655

12c01.5C0XPWP 12 7/0.53 0.7 1.25 20.5 890

19c01.5C0XPWP 19 7/0.53 0.7 1.6 23.7 1248

27c01.5C0XPWP 27 7/0.53 0.7 1.6 27.0 1567

37c01.5C0XPWP 37 7/0.53 0.7 1.6 29.6 1895

48c01.5C0XPWP 48 7/0.53 0.7 2.0 34.2 2465

Conductor 2.0 mm2

02c002C0XPWP 2 7/0.60 0.7 0.9 13.6 422

03c002C0XPWP 3 7/0.60 0.7 0.9 14.1 441

04c002C0XPWP 4 7/0.60 0.7 0.9 14.9 568

07c002C0XPWP 7 7/0.60 0.7 1.25 18.0 715

12c002C0XPWP 12 7/0.60 0.7 1.6 22.3 1102

19c002C0XPWP 19 7/0.60 0.7 1.6 25.0 1416

27c002C0XPWP 27 7/0.60 0.7 1.6 28.8 1781

37c002C0XPWP 37 7/0.60 0.7 1.6 31.7 2164

48c002C0XPWP 48 7/0.60 0.7 2.0 36.3 3012

Page 43: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

42 BICC CABLES

Product Code No. of CoresStrand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 2.5 mm2

02c02.5C0XPWP 2 7/0.67 0.7 0.9 13.9 446

03c02.5C0XPWP 3 7/0.67 0.7 0.9 14.4 469

04c02.5C0XPWP 4 7/0.67 0.7 0.9 15.2 608

07c02.5C0XPWP 7 7/0.67 0.7 1.25 18.3 780

12c02.5C0XPWP 12 7/0.67 0.7 1.6 22.8 1210

19c02.5C0XPWP 19 7/0.67 0.7 1.6 25.6 1560

27c02.5C0XPWP 27 7/0.67 0.7 1.6 29.6 1980

37c02.5C0XPWP 37 7/0.67 0.7 2.0 33.4 2665

48c02.5C0XPWP 48 7/0.67 0.7 2.0 37.5 3330

Conductor 3 mm2

02c003C0XPWP 2 7/0.74 0.7 0.9 14.3 468

03c003C0XPWP 3 7/0.74 0.7 0.9 14.9 573

04c003C0XPWP 4 7/0.74 0.7 1.25 16.5 644

07c003C0XPWP 7 7/0.74 0.7 1.25 19.0 835

12c003C0XPWP 12 7/0.74 0.7 1.6 23.8 1300

19c003C0XPWP 19 7/0.74 0.7 1.6 26.7 1690

27c003C0XPWP 27 7/0.74 0.7 1.6 31.1 2190

37c003C0XPWP 37 7/0.74 0.7 2.0 35.1 2935

Conductor 4 mm2

02c004C0XPWP 2 7/0.84 0.7 0.9 15.1 588

03c004C0XPWP 3 7/0.84 0.7 1.25 16.4 634

04c004C0XPWP 4 7/0.84 0.7 1.25 17.4 716

07c004C0XPWP 7 7/0.84 0.7 1.25 20.1 945

12c004C0XPWP 12 7/0.84 0.7 1.6 25.3 1480

19c004C0XPWP 19 7/0.84 0.7 1.6 28.8 1950

27c004C0XPWP 27 7/0.84 0.7 2.0 34.5 2770

37c004C0XPWP 37 7/0.84 0.7 2.0 38.0 3470

Follow: Control Cables, Armoured, XLPE Insulated

3.0 Control Cables

Page 44: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

43

Product Code No. of CoresStrand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 6 mm2

02c006C0XPWP 2 7/1.04 0.7 1.25 16.8 676

03c006C0XPWP 3 7/1.04 0.7 1.25 17.5 732

04c006C0XPWP 4 7/1.04 0.7 1.25 18.7 844

Conductor 10 mm2

02c010C0XPWP 2 7/1.36 0.7 1.25 18.9 827

03c010C0XPWP 3 7/1.36 0.7 1.25 19.2 929

04c010C0XPWP 4 7/1.36 0.7 1.25 20.5 1095

Follow: Control Cables, Armoured, XLPE Insulated

Page 45: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

44 BICC CABLES

Control Cables, Copper Tape Screened,PVC Insulated ApplicationThese cables are used for interconnecting of control devices and designed to be complete with copper tape screen applied helically after bedding.

Construction

1. ConductorStranded Copper class 2

2. InsulationPolyvinyl Chloride (PVC)

3. Screen Copper Tape Screen (CTS)

4. SheathPolyvinyl Chloride (PVC)

3.0 Control Cables

Page 46: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

45

Control Cables, Copper Tape Screened, PVC Insulated

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.0 mm2

05c001C0PPCTP 5 7/0.43 0.8 12.7 345

07c001C0PPCTP 7 7/0.43 0.8 14.1 402

10c001C0PPCTP 10 7/0.43 0.8 16.9 521

12c001C0PPCTP 12 7/0.43 0.8 17.4 568

14c001C0PPCTP 14 7/0.43 0.8 18.1 622

16c001C0PPCTP 16 7/0.43 0.8 18.9 678

19c001C0PPCTP 19 7/0.43 0.8 19.8 753

24c001C0PPCTP 24 7/0.43 0.8 22.7 907

30c001C0PPCTP 30 7/0.43 0.8 23.8 1045

37c001C0PPCTP 37 7/0.43 0.8 25.5 1212

Conductor 1.5 mm2

05c01.5C0PPCTP 5 7/0.53 0.8 13.3 392

07c01.5C0PPCTP 7 7/0.53 0.8 14.8 463

10c01.5C0PPCTP 10 7/0.53 0.8 17.9 607

12c01.5C0PPCTP 12 7/0.53 0.8 18.4 669

14c01.5C0PPCTP 14 7/0.53 0.8 19.1 736

16c01.5C0PPCTP 16 7/0.53 0.8 20.0 805

19c01.5C0PPCTP 19 7/0.53 0.8 21.0 901

24c01.5C0PPCTP 24 7/0.53 0.8 24.0 1091

30c01.5C0PPCTP 30 7/0.53 0.8 25.3 1268

37c01.5C0PPCTP 37 7/0.53 0.8 27.1 1480

Conductor 2.0 mm2

05c002C0PPCTP 5 7/0.60 0.8 14.0 434

07c002C0PPCTP 7 7/0.60 0.8 15.6 517

10c002C0PPCTP 10 7/0.60 0.8 18.9 681

12c002C0PPCTP 12 7/0.60 0.8 19.4 755

14c002C0PPCTP 14 7/0.60 0.8 20.3 835

16c002C0PPCTP 16 7/0.60 0.8 21.3 917

19c002C0PPCTP 19 7/0.60 0.8 22.3 1030

24c002C0PPCTP 24 7/0.60 0.8 25.6 1253

30c002C0PPCTP 30 7/0.60 0.8 27.2 1465

37c002C0PPCTP 37 7/0.60 0.8 29.2 1737

Page 47: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

46 BICC CABLES

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 2.5 mm2

05c02.5C0PPCTP 5 7/0.67 0.8 14.4 474

07c02.5C0PPCTP 7 7/0.67 0.8 15.9 572

10c02.5C0PPCTP 10 7/0.67 0.8 19.4 758

12c02.5C0PPCTP 12 7/0.67 0.8 20.0 844

14c02.5C0PPCTP 14 7/0.67 0.8 20.8 937

16c02.5C0PPCTP 16 7/0.67 0.8 21.9 1032

19c02.5C0PPCTP 19 7/0.67 0.8 22.9 1164

24c02.5C0PPCTP 24 7/0.67 0.8 26.4 1419

30c02.5C0PPCTP 30 7/0.67 0.8 28.0 1683

37c02.5C0PPCTP 37 7/0.67 0.8 30.1 1981

Conductor 3.0 mm2

05c003C0PPCTP 5 7/0.74 0.8 15.0 523

07c003C0PPCTP 7 7/0.74 0.8 16.6 634

10c003C0PPCTP 10 7/0.74 0.8 20.3 844

12c003C0PPCTP 12 7/0.74 0.8 20.9 942

14c003C0PPCTP 14 7/0.74 0.8 21.8 1045

16c003C0PPCTP 16 7/0.74 0.8 22.9 1154

19c003C0PPCTP 19 7/0.74 0.8 24.0 1303

24c003C0PPCTP 24 7/0.74 0.8 27.9 1609

30c003C0PPCTP 30 7/0.74 0.8 29.4 1893

37c003C0PPCTP 37 7/0.74 0.8 32.2 2299

Conductor 4.0 mm2

05c004C0PPCTP 5 7/0.84 1.0 17.1 633

07c004C0PPCTP 7 7/0.84 1.0 18.9 778

10c004C0PPCTP 10 7/0.84 1.0 23.4 1046

12c004C0PPCTP 12 7/0.84 1.0 24.1 1176

14c004C0PPCTP 14 7/0.84 1.0 25.3 1315

16c004C0PPCTP 16 7/0.84 1.0 26.6 1457

19c004C0PPCTP 19 7/0.84 1.0 28.1 1673

Follow: Control Cables, Copper Tape Screened, PVC Insulated

3.0 Control Cables

Page 48: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

47

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 4.0 mm2

24c004C0PPCTP 24 7/0.84 1.0 33.2 2123

30c004C0PPCTP 30 7/0.84 1.0 35.2 2537

37c004C0PPCTP 37 7/0.84 1.0 38.1 3017

Conductor 6 mm2

02c006C0PPCTP 2 7/1.04 1.0 15.0 490

03c006C0PPCTP 3 7/1.04 1.0 15.8 552

04c006C0PPCTP 4 7/1.04 1.0 17.1 660

05c006C0PPCTP 5 7/1.04 1.0 18.5 769

06c006C0PPCTP 6 7/1.04 1.0 20.5 881

07c006C0PPCTP 7 7/1.04 1.0 20.5 960

Conductor 10 mm2

02c010C0PPCTP 2 7/1.36 1.0 17.1 515

03c010C0PPCTP 3 7/1.36 1.0 18.0 645

04c010C0PPCTP 4 7/1.36 1.0 19.5 785

05c010C0PPCTP 5 7/1.36 1.0 21.1 945

06c010C0PP CTP 6 7/1.36 1.0 22.8 1065

07c010C0PPCTP 7 7/1.36 1.0 22.8 1178

Follow: Control Cables, Copper Tape Screened, PVC Insulated

Page 49: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

48 BICC CABLES

Control Cables, Copper Tape Screened,XLPE Insulated ApplicationThese cables are used for interconnecting of control devices and designed to be complete with copper tape screen applied helically.

Construction

1. ConductorStranded Copper class 2

2. InsulationCross Linked Polyethylene (XLPE)

3. Screen Copper Tape Screen (CTS)

4. SheathPolyvinyl Chloride (PVC)

3.0 Control Cables

Page 50: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

49

Control Cables, Copper Tape Screened, XLPE Insulated

Product Code No.of Cores

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.0 mm2

05c001C0XPCTP 5 7/0.43 0.7 12.2 306

07c001C0XPCTP 7 7/0.43 0.7 13.5 352

10c001C0XPCTP 10 7/0.43 0.7 16.1 450

12c001C0XPCTP 12 7/0.43 0.7 16.6 480

14c001C0XPCTP 14 7/0.43 0.7 17.2 530

16c001C0XPCTP 16 7/0.43 0.7 18.0 570

19c001C0XPCTP 19 7/0.43 0.7 18.8 630

24c001C0XPCTP 24 7/0.43 0.7 21.5 755

30c001C0XPCTP 30 7/0.43 0.7 22.6 860

37c001C0XPCTP 37 7/0.43 0.7 24.1 990

Conductor 1.5 mm2

05c01.5C0XPCTP 5 7/0.53 0.7 12.8 350

07c01.5C0XPCTP 7 7/0.53 0.7 14.2 410

10c01.5C0XPCTP 10 7/0.53 0.7 17.1 530

12c01.5C0XPCTP 12 7/0.53 0.7 17.5 580

14c01.5C0XPCTP 14 7/0.53 0.7 18.2 630

16c01.5C0XPCTP 16 7/0.53 0.7 19.1 689

19c01.5C0XPCTP 19 7/0.53 0.7 20.0 765

24c01.5C0XPCTP 24 7/0.53 0.7 22.8 920

30c01.5C0XPCTP 30 7/0.53 0.7 24.0 1060

37c01.5C0XPCTP 37 7/0.53 0.7 25.7 1230

Conductor 2.0 mm2

05c002C0XPCTP 5 7/0.60 0.7 13.5 390

07c002C0XPCTP 7 7/0.60 0.7 15.0 460

10c002C0XPCTP 10 7/0.60 0.7 18.1 600

12c002C0XPCTP 12 7/0.60 0.7 18.6 660

14c002C0XPCTP 14 7/0.60 0.7 19.4 730

16c002C0XPCTP 16 7/0.60 0.7 20.3 800

19c002C0XPCTP 19 7/0.60 0.7 21.3 890

24c002C0XPCTP 24 7/0.60 0.7 24.4 1080

30c002C0XPCTP 30 7/0.60 0.7 25.7 1250

37c002C0XPCTP 37 7/0.60 0.7 27.8 1450

Page 51: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

50 BICC CABLES

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 2.5 mm2

05c02.5C0XPCTP 5 7/0.67 0.7 13.9 430

07c02.5C0XPCTP 7 7/0.67 0.7 15.3 510

10c02.5C0XPCTP 10 7/0.67 0.7 18.6 670

12c02.5C0XPCTP 12 7/0.67 0.7 19.1 750

14c02.5C0XPCTP 14 7/0.67 0.7 20.0 820

16c02.5C0XPCTP 16 7/0.67 0.7 20.9 900

19c02.5C0XPCTP 19 7/0.67 0.7 21.9 1010

24c02.5C0XPCTP 24 7/0.67 0.7 25.2 1230

30c02.5C0XPCTP 30 7/0.67 0.7 26.5 1440

37c02.5C0XPCTP 37 7/0.67 0.7 29.1 1700

Conductor 3.0 mm2

05c003C0XPCTP 5 7/0.74 0.7 14.5 460

07c003C0XPCTP 7 7/0.74 0.7 16.0 560

10c003C0XPCTP 10 7/0.74 0.7 19.5 740

12c003C0XPCTP 12 7/0.74 0.7 20.1 820

14c003C0XPCTP 14 7/0.74 0.7 20.9 910

16c003C0XPCTP 16 7/0.74 0.7 22.0 1000

19c003C0XPCTP 19 7/0.74 0.7 23.0 1125

24c003C0XPCTP 24 7/0.74 0.7 26.5 1370

30c003C0XPCTP 30 7/0.74 0.7 28.1 1625

37c003C0XPCTP 37 7/0.74 0.7 30.8 1910

Conductor 4.0 mm2

05c004C0XPCTP 5 7/0.84 0.7 15.5 530

07c004C0XPCTP 7 7/0.84 0.7 17.1 640

10c004C0XPCTP 10 7/0.84 0.7 21.0 860

12c004C0XPCTP 12 7/0.84 0.7 21.6 960

14c004C0XPCTP 14 7/0.84 0.7 22.6 1060

16c004C0XPCTP 16 7/0.84 0.7 23.7 1175

Follow: Control Cables, Copper Tape Screened, XLPE Insulated

3.0 Control Cables

Page 52: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

51

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 4.0 mm2

19c004C0XPCTP 19 7/0.84 0.7 24.9 1330

24c004C0XPCTP 24 7/0.84 0.7 29.4 1645

30c004C0XPCTP 30 7/0.84 0.7 31.2 1940

37c004C0XPCTP 37 7/0.84 0.7 33.7 2350

Conductor 6 mm2

02c006C0XPCTP 2 7/1.04 0.7 13.8 430

03c006C0XPCTP 3 7/1.04 0.7 15.0 480

04c006C0XPCTP 4 7/1.04 0.7 15.7 570

05c006C0XPCTP 5 7/1.04 0.7 16.9 660

06c006C0XPCTP 6 7/1.04 0.7 18.7 750

07c006C0XPCTP 7 7/1.04 0.7 18.7 810

Conductor 10 mm2

02c010C0XPCTP 2 7/1.36 0.7 15.9 470

03c010C0XPCTP 3 7/1.36 0.7 16.7 550

04c010C0XPCTP 4 7/1.36 0.7 18.0 650

05c010C0XPCTP 5 7/1.36 0.7 19.5 800

06c010C0XPCTP 6 7/1.36 0.7 21.0 930

07c010C0XPCTP 7 7/1.36 0.7 21.0 1050

Follow: Control Cables, Copper Tape Screened, XLPE Insulated

Page 53: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

52 BICC CABLES

4.0 Instrument Cables

Page 54: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

53

4.0 Instrument Cables

Page 55: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

54 BICC CABLES

4.0 Instrument Cables

Application

Construction

Specification Standards

These cables are designed to connect electrical instrument circuits and provide communication services working as signal carrier used in and around process plants ( e.g. petrochemical industry etc.).

1. ConductorCopper (or Tinned Copper) in different flexibility degrees:- Solid Copper: Class 1- Stranded Copper: Class 2- Flexible Copper: Class 5

2. Insulation- Cross Linked Polyethylene (XLPE): Maximum conductor temperature is 90°C.- Polyvinyl Chloride (PVC) 70°C.- Polyvinyl Chloride (PVC) 105°C (for fire alarm cables).- Low Smoke Zero Halogen (LSOH) 90°C.

3. Shielding- Individual Shield: Shielding for each pair /triple in the multi pair/triple cables using Up to 50 μm Aluminium/ PET tape over tinned copper drain wires with 0.5 mm²- Overall Shield: Overall shield for all pairs / triples or cores in cable using Up to 50 μm Aluminium/ PET tape over tinned copper drain wires with 0.5 mm²

4. Bedding - Polyvinyl Chloride (PVC) - Low Smoke Zero Halogen (LSOH) (For applications where flame spread, minimal smoke and toxic gases emission are critical)

5. Armour / Screen- Armour: Galvanized Steel Wire Armour (GSWA) One layer of round wires is applied helically over the bedding

6. Outer Sheath- Polyvinyl Chloride (PVC) - Low Smoke Zero Halogen (LSOH)

Standard specification applied to cable:

Standard specification applied to conductor:

Spread of Flame

BS EN 50288-7 IEC 60228

Flame retardant as per IEC 60332-1

Page 56: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

55

Sizes

Core Identification

Options Available

Rated Voltage

This publication covers the following range

- Conductor area: From 0.5 mm2 up to 2.5 mm2

- No. of pairs: From one till 20 pairs - No. of triples: From one till 15 triples All variation from no. of pairs, triples and quads too are available upon request.

Sizes :All sizes are available upon request

Material :Where necessary, special features can be incorporated into the cable enabling it to have:- Improved fire performance- Low smoke and fume (Halogen free )- Termite resistance- Resistance to attack from oils, solvents or corrosive chemicals

For environment where emissions of smoke and toxic gases are critical , insulation , bedding and outer sheath material can be : Low Smoke Zero Halogen which has abbreviations of LS0H , LSOH & LSZH( the 3 abbreviations are the same material) with no halogen content and controlled emission of smokeAlso, it is the same as Low Smoke Halogen Free (LSHF).

Note: Values in the following tables are approximate and subject to manufacturing tolerance.

500 V

- Pair: White & Black - Triple: White, Black & Red - Multi Cores more than five cores: Black with white numbers

Other special colors are available upon request. For multi pair and traid colored cores are identified by numbers on the white core only and can be on each coe (upon request)

Page 57: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

56 BICC CABLES

Multi Pair/Triple & Multi Core, Non Armoured, Overall Shielding ApplicationMulti pair/triple & multi core instrument cables are used as signal carrier for connecting electrical instrument circuits.

Construction

1. ConductorStranded Copper class 2

2. InsulationPolyvinyl Chloride (PVC)Alternative: Cross Linked Polyethylene (XLPE )

3. Shielding Overall Shielding 4. SheathPolyvinyl Chloride (PVC)

4.0 Instrument Cables

Page 58: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

57

Multi Pair Instrument Cables, Non Armoured, Overall Shielded

Product Code No. of Pairs

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

01p00.5C0P0S000P 1 7/0.30 0.6 6.2 66

02p00.5C0POS000P 2 7/0.30 0.6 10.8 98

04p00.5C0POS000P 4 7/0.30 0.6 12.8 199

06p00.5C0POS000P 6 7/0.30 0.6 13.6 264

10p00.5C0POS000P 10 7/0.30 0.6 17.8 379

15p00.5C0POS000P 15 7/0.30 0.6 21.0 539

20p00.5C0POS000P 20 7/0.30 0.6 24.0 675

Conductor 0.75 mm2

01p0.75C0POS000P 1 7/0.37 0.6 7.0 74

02p0.75C0POS000P 2 7/0.37 0.6 11.9 109

04p0.75C0POS000P 4 7/0.37 0.6 14.0 231

06p0.75C0POS000P 6 7/0.37 0.6 14.7 303

10p0.75C0POS000P 10 7/0.37 0.6 19.4 463

15p0.75C0POS000P 15 7/0.37 0.6 22.6 646

20p0.75C0POS000P 20 7/0.37 0.6 25.9 845

Conductor 1.0 mm2

01p1.00C0POS000P 1 7/0.43 0.6 7.1 79

02p1.00C0POS000P 2 7/0.43 0.6 13.0 152

04p1.00C0POS000P 4 7/0.43 0.6 15.4 282

06p1.00C0POS000P 6 7/0.43 0.6 16.4 383

10p1.00C0POS000P 10 7/0.43 0.6 21.7 589

15p1.00C0POS000P 15 7/0.43 0.6 25.7 803

20p1.00C0POS000P 20 7/0.43 0.6 29.3 1047

Page 59: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

58 BICC CABLES

Product Code No. of Pairs

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01p1.50C0POS000P 1 7/0.53 0.6 7.6 99

02p1.50C0POS000P 2 7/0.53 0.6 14.0 159

04p1.50C0POS000P 4 7/0.53 0.6 16.5 328

06p1.50C0POS000P 6 7/0.53 0.6 17.7 445

10p1.50C0POS000P 10 7/0.53 0.6 23.9 665

15p1.50C0POS000P 15 7/0.53 0.6 27.8 975

20p1.50C0POS000P 20 7/0.53 0.6 31.7 1276

Conductor 2.0 mm2

01p2.00C0POS000P 1 7/0.60 0.6 8.0 124

02p2.00C0POS000P 2 7/0.60 0.6 15.2 208

04p2.00C0POS000P 4 7/0.60 0.6 17.8 417

06p2.00C0POS000P 6 7/0.60 0.6 19.5 588

10p2.00C0POS000P 10 7/0.60 0.6 26.0 929

15p2.00C0POS000P 15 7/0.60 0.6 30.7 1334

20p2.00C0POS000P 20 7/0.60 0.6 35.1 1700

Conductor 2.5 mm2

01p2.50C0POS000P 1 7/0.67 0.6 8.4 131

02p2.50C0POS000P 2 7/0.67 0.6 15.7 221

04p2.50C0POS000P 4 7/0.67 0.6 18.4 443

06p2.50C0POS000P 6 7/0.67 0.6 20.3 627

10p2.50C0POS000P 10 7/0.67 0.6 27.0 994

15p2.50C0POS000P 15 7/0.67 0.6 31.9 1433

20p2.50C0POS000P 20 7/0.67 0.6 36.5 1892

Follow: Multi Pair Instrument Cables, Non Armoured, Overall Shielded

4.0 Instrument Cables

Page 60: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

59

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

01t00.5C0POS000P 1 7/0.30 0.6 6.5 76

02t00.5C0POS000P 2 7/0.30 0.6 11.7 137

04t00.5C0POS000P 4 7/0.30 0.6 11.9 253

06t00.5C0POS000P 6 7/0.30 0.6 14.6 331

10t00.5C0POS000P 10 7/0.30 0.6 19.2 500

12t00.5C0POS000P 12 7/0.30 0.6 20.0 579

15t00.5C0POS000P 15 7/0.30 0.6 22.4 726

Conductor 0.75 mm2

01t0.75C0POS000P 1 7/0.37 0.6 6.8 88

02t0.75C0POS000P 2 7/0.37 0.6 12.5 159

04t0.75C0POS000P 4 7/0.37 0.6 12.9 303

06t0.75C0POS000P 6 7/0.37 0.6 15.7 394

10t0.75C0POS000P 10 7/0.37 0.6 20.8 611

12t0.75C0POS000P 12 7/0.37 0.6 21.6 738

15t0.75C0POS000P 15 7/0.37 0.6 24.0 890

Conductor 1.0 mm2

01t1.00C0POS000P 1 7/0.43 0.6 7.5 103

02t1.00C0POS000P 2 7/0.43 0.6 14.0 203

04t1.00C0POS000P 4 7/0.43 0.6 14.5 356

06t1.00C0POS000P 6 7/0.43 0.6 17.5 501

10t1.00C0POS000P 10 7/0.43 0.6 23.6 762

12t1.00C0POS000P 12 7/0.43 0.6 24.5 887

15t1.00C0POS000P 15 7/0.43 0.6 27.5 1074

Multi Triple Instrument Cables, Non Armoured, Overall Shielded

Page 61: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

60 BICC CABLES

Follow: Multi Triple Instrument Cables, Non Armoured, Overall Shielded

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01t1.50C0POS000P 1 7/0.53 0.6 8.0 127

02t1.50C0POS000P 2 7/0.53 0.6 14.5 249

04t1.50C0POS000P 4 7/0.53 0.6 15.6 431

06t1.50C0POS000P 6 7/0.53 0.6 19.2 612

10t1.50C0POS000P 10 7/0.53 0.6 25.6 940

12t1.50C0POS000P 12 7/0.53 0.6 26.6 1099

15t1.50C0POS000P 15 7/0.53 0.6 30.0 1372

Conductor 2.0 mm2

01t2.00C0POS000P 1 7/0.60 0.6 8.6 159

02t2.00C0POS000P 2 7/0.60 0.6 16.0 312

04t2.00C0POS000P 4 7/0.60 0.6 16.9 551

06t2.00C0POS000P 6 7/0.60 0.6 20.9 798

10t2.00C0POS000P 10 7/0.60 0.6 27.9 1270

12t2.00C0POS000P 12 7/0.60 0.6 29.3 1464

15t2.00C0POS000P 15 7/0.60 0.6 32.9 1843

Conductor 2.5 mm2

01t2.50C0POS000P 1 7/0.67 0.6 9.0 162

02t2.50C0POS000P 2 7/0.67 0.6 16.7 350

04t2.50C0POS000P 4 7/0.67 0.6 18.5 578

06t2.50C0POS000P 6 7/0.67 0.6 22.0 830

10t2.50C0POS000P 10 7/0.67 0.6 29.4 1334

12t2.50C0POS000P 12 7/0.67 0.6 30.5 1548

15t2.50C0POS000P 15 7/0.67 0.6 34.8 1933

4.0 Instrument Cables

Page 62: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

61

Multi Core Instrument Cables, Non Armoured, Overall Shielded

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

02c00.5C0POS000P 2 7/0.30 0.6 6.2 65

03c00.5C0POS000P 3 7/0.30 0.6 6.5 76

04c00.5C0POS000P 4 7/0.30 0.6 7.0 91

05c00.5C0POS000P 5 7/0.30 0.6 7.6 107

07c00.5C0POS000P 7 7/0.30 0.6 8.2 140

12c00.5C0POS000P 12 7/0.30 0.6 10.5 225

19c00.5C0POS000P 19 7/0.30 0.6 12.8 324

24c00.5C0POS000P 24 7/0.30 0.6 15.0 398

Conductor 0.75 mm2

02c0.75C0POS000P 2 7/0.37 0.6 6.6 74

03c0.75C0POS000P 3 7/0.37 0.6 6.9 89

04c0.75C0POS000P 4 7/0.37 0.6 7.5 106

05c0.75C0POS000P 5 7/0.37 0.6 8.1 131

07c0.75C0POS000P 7 7/0.37 0.6 8.9 165

12c0.75C0POS000P 12 7/0.37 0.6 11.9 268

19c0.75C0POS000P 19 7/0.37 0.6 13.9 390

24c0.75C0POS000P 24 7/0.37 0.6 16.1 482

Conductor 1.0 mm2

02c1.00C0POS000P 2 7/0.43 0.6 7.1 82

03c1.00C0POS000P 3 7/0.43 0.6 7.5 100

04c1.00C0POS000P 4 7/0.43 0.6 8.2 122

05c1.00C0POS000P 5 7/0.43 0.6 9.0 155

07c1.00C0POS000P 7 7/0.43 0.6 9.8 195

12c1.00C0POS000P 12 7/0.43 0.6 13.0 319

19c1.00C0POS000P 19 7/0.43 0.6 15.3 458

24c1.00C0POS000P 24 7/0.43 0.6 17.8 578

Page 63: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

62 BICC CABLES

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 1.5 mm2

02c1.50C0POS000P 2 7/0.53 0.6 7.6 98

03c1.50C0POS000P 3 7/0.53 0.6 8.0 132

04c1.50C0POS000P 4 7/0.53 0.6 8.9 161

05c1.50C0POS000P 5 7/0.53 0.6 9.7 191

07c1.50C0POS000P 7 7/0.53 0.6 10.5 260

12c1.50C0POS000P 12 7/0.53 0.6 14.2 417

19c1.50C0POS000P 19 7/0.53 0.6 16.5 602

24c1.50C0POS000P 24 7/0.53 0.6 19.3 761

Conductor 2.0 mm2

02c2.00C0POS000P 2 7/0.60 0.6 8.1 124

03c2.00C0POS000P 3 7/0.60 0.6 8.6 161

04c2.00C0POS000P 4 7/0.60 0.6 9.5 199

05c2.00C0POS000P 5 7/0.60 0.6 10.4 252

07c2.00C0POS000P 7 7/0.60 0.6 11.7 322

12c2.00C0POS000P 12 7/0.60 0.6 15.3 512

19c2.00C0POS000P 19 7/0.60 0.6 17.8 763

24c2.00C0POS000P 24 7/0.60 0.6 20.9 947

Conductor 2.5 mm2

02c2.50C0POS000P 2 7/0.67 0.6 8.4 136

03c2.50C0POS000P 3 7/0.67 0.6 9.1 171

04c2.50C0POS000P 4 7/0.67 0.6 9.9 211

05c2.50C0POS000P 5 7/0.67 0.6 10.7 268

07c2.50C0POS000P 7 7/0.67 0.6 12.0 344

12c2.50C0POS000P 12 7/0.67 0.6 15.8 550

19c2.50C0POS000P 19 7/0.67 0.6 18.6 824

24c2.50C0POS000P 24 7/0.67 0.6 21.7 1053

Follow: Multi Core Instrument Cables, Non Armoured, Overall Shielded

4.0 Instrument Cables

Page 64: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

63

The highest purity of copper

Page 65: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

64 BICC CABLES

Multi Pair/Triple, Non Armoured,Individual & Overall ShieldingApplicationMulti pair/triple instrument cables are used as signal carrier for connecting electrical instrument circuits.

Construction

1. ConductorStranded Copper class 2

2. InsulationPolyvinyl Chloride (PVC)Alternative: Cross Linked Polyethylene (XLPE )

3. Shielding Individual & Overall Shielding 4. SheathPolyvinyl Chloride (PVC)

4.0 Instrument Cables

Page 66: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

65

Product Code No. of Pairs

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

02p00.5C0PISOS00P 2 7/0.30 0.6 12.0 164

04p00.5C0PISOS00P 4 7/0.30 0.6 13.7 247

06p00.5C0PISOS00P 6 7/0.30 0.6 14.2 327

10p00.5C0PISOS00P 10 7/0.30 0.6 18.8 506

15p00.5C0PISOS00P 15 7/0.30 0.6 21.9 723

20p00.5C0PISOS00P 20 7/0.30 0.6 25.0 910

Conductor 0.75 mm2

02p0.75C0PISOS00P 2 7/0.37 0.6 12.3 187

04p0.75C0PISOS00P 4 7/0.37 0.6 14.5 294

06p0.75C0PISOS00P 6 7/0.37 0.6 15.3 397

10p0.75C0PISOS00P 10 7/0.37 0.6 20.2 589

15p0.75C0PISOS00P 15 7/0.37 0.6 24.0 845

20p0.75C0PISOS00P 20 7/0.37 0.6 27.0 1104

Conductor 1.0 mm2

02p1.00C0PISOS00P 2 7/0.43 0.6 13.6 205

04p1.00C0PISOS00P 4 7/0.43 0.6 15.8 327

06p1.00C0PISOS00P 6 7/0.43 0.6 17.0 461

10p1.00C0PISOS00P 10 7/0.43 0.6 22.5 731

15p1.00C0PISOS00P 15 7/0.43 0.6 26.6 1002

20p1.00C0PISOS00P 20 7/0.43 0.6 30.4 1310

Conductor 1.5 mm2

02p1.50C0PISOS00P 2 7/0.53 0.6 14.6 253

04p1.50C0PISOS00P 4 7/0.53 0.6 17.0 394

06p1.50C0PISOS00P 6 7/0.53 0.6 18.5 558

10p1.50C0PISOS00P 10 7/0.53 0.6 24.7 853

15p1.50C0PISOS00P 15 7/0.53 0.6 29.2 1222

20p1.50C0PISOS00P 20 7/0.53 0.6 32.8 1616

Conductor 2.0 mm2

02p2.00C0PISOS00P 2 7/0.60 0.6 15.6 312

04p2.00C0PISOS00P 4 7/0.60 0.6 18.5 487

06p2.00C0PISOS00P 6 7/0.60 0.6 20.1 624

10p2.00C0PISOS00P 10 7/0.60 0.6 26.8 1013

15p2.00C0PISOS00P 15 7/0.60 0.6 32.0 1538

20p2.00C0PISOS00P 20 7/0.60 0.6 36.0 1986

Multi Pair Instrument Cables, Non Armoured,Individual & Overall Shielded

Page 67: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

66 BICC CABLES

Multi Triple Instrument Cables, Non Armoured,Individual & Overall Shielded

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

02t00.5C0PISOS00P 2 7/0.30 0.6 12.2 184

04t00.5C0PISOS00P 4 7/0.30 0.6 12.4 283

06t00.5C0PISOS00P 6 7/0.30 0.6 15.0 380

10t00.5C0PISOS00P 10 7/0.30 0.6 20.1 620

12t00.5C0PISOS00P 12 7/0.30 0.6 20.8 707

15t00.5C0PISOS00P 15 7/0.30 0.6 23.8 852

Conductor 0.75 mm2

02t0.75C0PISOS00P 2 7/0.37 0.6 13.0 224

04t0.75C0PISOS00P 4 7/0.37 0.6 13.1 347

06t0.75C0PISOS00P 6 7/0.37 0.6 16.3 491

10t0.75C0PISOS00P 10 7/0.37 0.6 21.6 749

12t0.75C0PISOS00P 12 7/0.37 0.6 22.5 892

15t0.75C0PISOS00P 15 7/0.37 0.6 25.6 1073

Product Code No. of Pairs

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 2.5 mm2

02p2.50C0PISOS00P 2 7/0.67 0.6 16.0 325

04p2.50C0PISOS00P 4 7/0.67 0.6 19.0 526

06p2.50C0PISOS00P 6 7/0.67 0.6 20.9 736

10p2.50C0PISOS00P 10 7/0.67 0.6 27.8 1221

15p2.50C0PISOS00P 15 7/0.67 0.6 32.8 1683

20p2.50C0PISOS00P 20 7/0.67 0.6 37.6 2229

4.0 Instrument Cables

Follow: Multi Pair Instrument Cables, Non Armoured,Individual & Overall Shielded

Page 68: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

67

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.0 mm2

02t1.00C0PISOS00P 2 7/0.43 0.6 14.4 240

04t1.00C0PISOS00P 4 7/0.43 0.6 14.8 391

06t1.00C0PISOS00P 6 7/0.43 0.6 18.0 556

10t1.00C0PISOS00P 10 7/0.43 0.6 24.5 888

12t1.00C0PISOS00P 12 7/0.43 0.6 25.4 1016

15t1.00C0PISOS00P 15 7/0.43 0.6 28.9 1271

Conductor 1.5 mm2

02t1.50C0PISOS00P 2 7/0.53 0.6 15.4 296

04t1.50C0PISOS00P 4 7/0.53 0.6 16.0 489

06t1.50C0PISOS00P 6 7/0.53 0.6 19.8 712

10t1.50C0PISOS00P 10 7/0.53 0.6 26.4 1090

12t1.50C0PISOS00P 12 7/0.53 0.6 27.4 1300

15t1.50C0PISOS00P 15 7/0.53 0.6 31.2 1584

Conductor 2.0 mm2

02t2.00C0PISOS00P 2 7/0.60 0.6 16.5 370

04t2.00C0PISOS00P 4 7/0.60 0.6 17.4 610

06t2.00C0PISOS00P 6 7/0.60 0.6 21.5 781

10t2.00C0PISOS00P 10 7/0.60 0.6 29.0 1304

12t2.00C0PISOS00P 12 7/0.60 0.6 30.2 1576

15t2.00C0PISOS00P 15 7/0.60 0.6 33.8 1933

Conductor 2.5 mm2

02t2.50C0PISOS00P 2 7/0.67 0.6 17.0 389

04t2.50C0PISOS00P 4 7/0.67 0.6 18.0 648

06t2.50C0PISOS00P 6 7/0.67 0.6 22.4 916

10t2.50C0PISOS00P 10 7/0.67 0.6 30.2 1523

12t2.50C0PISOS00P 12 7/0.67 0.6 31.3 1741

15t2.50C0PISOS00P 15 7/0.67 0.6 35.8 2127

Follow: Multi Triple Instrument Cables, Non Armoured,Individual & Overall Shielded

Page 69: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

68 BICC CABLES

Multi Pair/Triple & Multi Core, Armoured,Overall ShieldingApplicationMulti pair/triple & multi core instrument cables are used as signal carrier for connecting electrical instrument circuits.

Construction

1. ConductorStranded Copper class 2

2. InsulationPolyvinyl Chloride (PVC)Alternative: Cross Linked Polyethylene (XLPE )

3. Shielding Overall Shielding

4. ArmourGalvanized Round Steel Wire (GSWA) 5. SheathPolyvinyl Chloride (PVC)

4.0 Instrument Cables

Page 70: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

69

Product Code No. of Pairs

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

01p00.5C0POS0PWP 1 7/0.30 0.6 0.9 11.1 277

02p00.5C0POS0PWP 2 7/0.30 0.6 1.25 16.8 334

04p00.5C0POS0PWP 4 7/0.30 0.6 1.25 19.0 669

06p00.5C0POS0PWP 6 7/0.30 0.6 1.25 19.8 804

10p00.5C0POS0PWP 10 7/0.30 0.6 1.6 24.9 1189

15p00.5C0POS0PWP 15 7/0.30 0.6 1.6 28.2 1507

20p00.5C0POS0PWP 20 7/0.30 0.6 1.6 31.3 1755

Conductor 0.75 mm2

01p0.75C0POS0PWP 1 7/0.37 0.6 0.9 11.5 296

02p0.75C0POS0PWP 2 7/0.37 0.6 1.25 17.9 365

04p0.75C0POS0PWP 4 7/0.37 0.6 1.25 20.2 730

06p0.75C0POS0PWP 6 7/0.37 0.6 1.25 21.0 1011

10p0.75C0POS0PWP 10 7/0.37 0.6 1.6 26.5 1338

15p0.75C0POS0PWP 15 7/0.37 0.6 1.6 29.9 1701

20p0.75C0POS0PWP 20 7/0.37 0.6 2.0 34.2 2266

Conductor 1.0 mm2

01p1.00C0POS0PWP 1 7/0.43 0.6 0.9 12.0 297

02p1.00C0POS0PWP 2 7/0.43 0.6 1.25 19.0 511

04p1.00C0POS0PWP 4 7/0.43 0.6 1.6 22.3 850

06p1.00C0POS0PWP 6 7/0.43 0.6 1.6 23.5 1204

10p1.00C0POS0PWP 10 7/0.43 0.6 1.6 29.0 1664

15p1.00C0POS0PWP 15 7/0.43 0.6 2.0 34.0 2284

20p1.00C0POS0PWP 20 7/0.43 0.6 2.0 37.8 2735

Conductor 1.5 mm2

01p1.50C0POS0PWP 1 7/0.53 0.6 0.9 12.5 354

02p1.50C0POS0PWP 2 7/0.53 0.6 1.25 20.4 532

04p1.50C0POS0PWP 4 7/0.53 0.6 1.6 23.6 1036

06p1.50C0POS0PWP 6 7/0.53 0.6 1.6 24.8 1271

10p1.50C0POS0PWP 10 7/0.53 0.6 1.6 31.2 1689

15p1.50C0POS0PWP 15 7/0.53 0.6 2.0 36.3 2472

20p1.50C0POS0PWP 20 7/0.53 0.6 2.0 40.4 2969

Multi Pair Instrument Cables, Armoured, Overall Shielded

Page 71: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

70 BICC CABLES

Product Code No. of Pairs

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 2.0 mm2

01p2.00C0POS0PWP 1 7/0.60 0.6 0.9 13.2 401

02p2.00C0POS0PWP 2 7/0.60 0.6 1.6 22.1 613

04p2.00C0POS0PWP 4 7/0.60 0.6 1.6 24.9 1195

06p2.00C0POS0PWP 6 7/0.60 0.6 1.6 26.6 1508

10p2.00C0POS0PWP 10 7/0.60 0.6 2.0 34.3 2302

15p2.00C0POS0PWP 15 7/0.60 0.6 2.0 39.2 3043

20p2.00C0POS0PWP 20 7/0.60 0.6 2.5 44.5 3645

Conductor 2.5 mm2

01p2.50C0POS0PWP 1 7/0.67 0.6 0.9 13.5 410

02p2.50C0POS0PWP 2 7/0.67 0.6 1.6 22.6 629

04p2.50C0POS0PWP 4 7/0.67 0.6 1.6 25.5 1251

06p2.50C0POS0PWP 6 7/0.67 0.6 1.6 27.4 1564

10p2.50C0POS0PWP 10 7/0.67 0.6 2.0 35.3 2408

15p2.50C0POS0PWP 15 7/0.67 0.6 2.0 40.4 3166

20p2.50C0POS0PWP 20 7/0.67 0.6 2.5 45.9 4231

Follow: Multi Pair Instrument Cables, Armoured, Overall Shielded

4.0 Instrument Cables

Page 72: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

71

Multi Triple Instrument Cables, Armoured, Overall Shielded

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter

(mm)

Overall Cable Diameter

(mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

01t00.5C0POS0PWP 1 7/0.30 0.6 0.9 11.4 297

02t00.5C0POS0PWP 2 7/0.30 0.6 1.25 17.8 521

04t00.5C0POS0PWP 4 7/0.30 0.6 1.25 19.0 771

06t00.5C0POS0PWP 6 7/0.30 0.6 1.25 20.8 1046

10t00.5C0POS0PWP 10 7/0.30 0.6 1.6 26.4 1406

12t00.5C0POS0PWP 12 7/0.30 0.6 1.6 27.3 1548

15t00.5C0POS0PWP 15 7/0.30 0.6 1.6 29.7 1805

Conductor 0.75 mm2

01t0.75C0POS0PWP 1 7/0.37 0.6 0.9 11.8 320

02t0.75C0POS0PWP 2 7/0.37 0.6 1.25 18.6 585

04t0.75C0POS0PWP 4 7/0.37 0.6 1.25 19.7 981

06t0.75C0POS0PWP 6 7/0.37 0.6 1.6 22.6 1185

10t0.75C0POS0PWP 10 7/0.37 0.6 1.6 28.1 1597

12t0.75C0POS0PWP 12 7/0.37 0.6 1.6 28.9 1811

15t0.75C0POS0PWP 15 7/0.37 0.6 1.6 32.3 2311

Conductor 1.0 mm2

01t1.00C0POS0PWP 1 7/0.43 0.6 0.9 12.4 345

02t1.00C0POS0PWP 2 7/0.43 0.6 1.25 20.2 653

04t1.00C0POS0PWP 4 7/0.43 0.6 1.25 21.5 1056

06t1.00C0POS0PWP 6 7/0.43 0.6 1.6 24.6 1327

10t1.00C0POS0PWP 10 7/0.43 0.6 1.6 31.0 1803

12t1.00C0POS0PWP 12 7/0.43 0.6 1.6 32.0 2234

15t1.00C0POS0PWP 15 7/0.43 0.6 2.0 36.0 2554

Page 73: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

72 BICC CABLES

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness (mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01t1.50C0POS0PWP 1 7/0.53 0.6 0.9 13.1 400

02t1.50C0POS0PWP 2 7/0.53 0.6 1.25 21.2 754

04t1.50C0POS0PWP 4 7/0.53 0.6 1.6 22.4 1220

06t1.50C0POS0PWP 6 7/0.53 0.6 1.6 26.3 1528

10t1.50C0POS0PWP 10 7/0.53 0.6 2.0 33.9 2337

12t1.50C0POS0PWP 12 7/0.53 0.6 2.0 35.1 2616

15t1.50C0POS0PWP 15 7/0.53 0.6 2.0 38.7 3061

Conductor 2.0 mm2

01t2.00C0POS0PWP 1 7/0.60 0.6 0.9 13.7 455

02t2.00C0POS0PWP 2 7/0.60 0.6 1.6 23.0 820

04t2.00C0POS0PWP 4 7/0.60 0.6 1.6 24.0 1429

06t2.00C0POS0PWP 6 7/0.60 0.6 1.6 28.2 1847

10t2.00C0POS0PWP 10 7/0.60 0.6 2.0 36.4 2863

12t2.00C0POS0PWP 12 7/0.60 0.6 2.0 37.8 3173

15t2.00C0POS0PWP 15 7/0.60 0.6 2.0 41.6 3808

Conductor 2.5 mm2

01t2.50C0POS0PWP 1 7/0.67 0.6 0.9 14.2 535

02t2.50C0POS0PWP 2 7/0.67 0.6 1.6 23.8 890

04t2.50C0POS0PWP 4 7/0.67 0.6 1.6 24.7 1463

06t2.50C0POS0PWP 6 7/0.67 0.6 1.6 29.1 1863

10t2.50C0POS0PWP 10 7/0.67 0.6 2.0 37.9 2907

12t2.50C0POS0PWP 12 7/0.67 0.6 2.0 39.0 3259

15t2.50C0POS0PWP 15 7/0.67 0.6 2.0 43.7 3840

Follow: Multi Triple Instrument Cables, Armoured, Overall Shielded

4.0 Instrument Cables

Page 74: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

73

Multi Core Instrument Cables, Armoured, Overall Shielded

Product Code No. of Cores

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

02c00.5C0POS0PWP 2 7/0.30 0.6 0.9 11.1 277

03c00.5C0POS0PWP 3 7/0.30 0.6 0.9 11.4 297

04c00.5C0POS0PWP 4 7/0.30 0.6 0.9 11.9 327

05c00.5C0POS0PWP 5 7/0.30 0.6 0.9 12.5 367

07c00.5C0POS0PWP 7 7/0.30 0.6 0.9 13.3 423

12c00.5C0POS0PWP 12 7/0.30 0.6 1.25 16.3 695

19c00.5C0POS0PWP 19 7/0.30 0.6 1.25 18.8 865

24c00.5C0POS0PWP 24 7/0.30 0.6 1.25 21.2 1157

Conductor 0.75 mm2

02c0.75C0POS0PWP 2 7/0.37 0.6 0.9 11.5 292

03c0.75C0POS0PWP 3 7/0.37 0.6 0.9 11.8 316

04c0.75C0POS0PWP 4 7/0.37 0.6 0.9 12.4 357

05c0.75C0POS0PWP 5 7/0.37 0.6 0.9 13.2 408

07c0.75C0POS0PWP 7 7/0.37 0.6 0.9 14.0 539

12c0.75C0POS0PWP 12 7/0.37 0.6 1.25 17.9 759

19c0.75C0POS0PWP 19 7/0.37 0.6 1.25 20.1 1090

24c0.75C0POS0PWP 24 7/0.37 0.6 1.6 23.0 1295

Conductor 1.0 mm2

02c1.00C0POS0PWP 2 7/0.43 0.6 0.9 12.0 313

03c1.00C0POS0PWP 3 7/0.43 0.6 0.9 12.4 343

04c1.00C0POS0PWP 4 7/0.43 0.6 0.9 13.3 390

05c1.00C0POS0PWP 5 7/0.43 0.6 0.9 14.1 526

07c1.00C0POS0PWP 7 7/0.43 0.6 0.9 14.9 593

12c1.00C0POS0PWP 12 7/0.43 0.6 1.25 19.0 850

19c1.00C0POS0PWP 19 7/0.43 0.6 1.6 22.2 1204

24c1.00C0POS0PWP 24 7/0.43 0.6 1.6 24.9 1458

Page 75: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

74 BICC CABLES

Product Code No. of Cores

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02c1.50C0POS0PWP 2 7/0.53 0.6 0.9 12.5 353

03c1.50C0POS0PWP 3 7/0.53 0.6 0.9 13.1 405

04c1.50C0POS0PWP 4 7/0.53 0.6 0.9 14.1 534

05c1.50C0POS0PWP 5 7/0.53 0.6 0.9 14.8 591

07c1.50C0POS0PWP 7 7/0.53 0.6 1.25 16.3 714

12c1.50C0POS0PWP 12 7/0.53 0.6 1.25 20.4 1125

19c1.50C0POS0PWP 19 7/0.53 0.6 1.6 23.6 1427

24c1.50C0POS0PWP 24 7/0.53 0.6 1.6 26.4 1718

Conductor 2.0 mm2

02c2.00C0POS0PWP 2 7/0.60 0.6 0.9 13.2 400

03c2.00C0POS0PWP 3 7/0.60 0.6 0.9 13.7 538

04c2.00C0POS0PWP 4 7/0.60 0.6 0.9 14.6 604

05c2.00C0POS0PWP 5 7/0.60 0.6 1.25 16.2 713

07c2.00C0POS0PWP 7 7/0.60 0.6 1.25 17.7 817

12c2.00C0POS0PWP 12 7/0.60 0.6 1.6 22.2 1291

19c2.00C0POS0PWP 19 7/0.60 0.6 1.6 24.9 1683

24c2.00C0POS0PWP 24 7/0.60 0.6 1.6 28.2 2026

Conductor 2.5 mm2

02c2.50C0POS0PWP 2 7/0.67 0.6 0.9 13.5 422

03c2.50C0POS0PWP 3 7/0.67 0.6 0.9 14.2 550

04c2.50C0POS0PWP 4 7/0.67 0.6 0.9 15.0 620

05c2.50C0POS0PWP 5 7/0.67 0.6 1.25 16.7 732

07c2.50C0POS0PWP 7 7/0.67 0.6 1.25 18.0 843

12c2.50C0POS0PWP 12 7/0.67 0.6 1.6 22.7 1359

19c2.50C0POS0PWP 19 7/0.67 0.6 1.6 25.7 1762

24c2.50C0POS0PWP 24 7/0.67 0.6 1.6 29.0 2168

Follow: Multi Core Instrument Cables, Armoured, Overall Shielded

4.0 Instrument Cables

Page 76: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

75

Galvanize the moment with the best cable

Page 77: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

76 BICC CABLES

Multi Pair/Triple, Armoured,Individual & Overall ShieldingApplicationMulti pair/triple instrument cables are used as signal carrier for connecting electrical instrument circuits.

Construction

1. ConductorStranded Copper class 2

2. InsulationPolyvinyl Chloride (PVC)Alternative: Cross Linked Polyethylene (XLPE )

3. Shielding Individual & Overall Shielding

4. ArmourGalvanized Round Steel Wire (GSWA) 5. SheathPolyvinyl Chloride (PVC)

4.0 Instrument Cables

Page 78: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

77

Product Code No. of Pairs

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

02p00.5C0PISOSPWP 2 7/0.30 0.6 1.25 17.6 622

04p00.5C0PISOSPWP 4 7/0.30 0.6 1.25 19.8 774

06p00.5C0PISOSPWP 6 7/0.30 0.6 1.25 20.4 1083

10p00.5C0PISOSPWP 10 7/0.30 0.6 1.6 25.9 1489

15p00.5C0PISOSPWP 15 7/0.30 0.6 1.6 29.2 2071

20p00.5C0PISOSPWP 20 7/0.30 0.6 1.6 32.6 2422

Conductor 0.75 mm2

02p0.75C0PISOSPWP 2 7/0.37 0.6 1.25 18.3 672

04p0.75C0PISOSPWP 4 7/0.37 0.6 1.25 20.7 985

06p0.75C0PISOSPWP 6 7/0.37 0.6 1.6 22.2 1220

10p0.75C0PISOSPWP 10 7/0.37 0.6 1.6 27.5 1643

15p0.75C0PISOSPWP 15 7/0.37 0.6 1.6 31.3 2312

20p0.75C0PISOSPWP 20 7/0.37 0.6 2.0 35.5 2771

Conductor 1.0 mm2

02p1.00C0PISOSPWP 2 7/0.43 0.6 1.25 19.8 707

04p1.00C0PISOSPWP 4 7/0.43 0.6 1.6 22.8 1042

06p1.00C0PISOSPWP 6 7/0.43 0.6 1.6 24.1 1324

10p1.00C0PISOSPWP 10 7/0.43 0.6 1.6 29.8 2055

15p1.00C0PISOSPWP 15 7/0.43 0.6 2.0 35.1 2528

20p1.00C0PISOSPWP 20 7/0.43 0.6 2.0 38.9 3045

Conductor 1.5 mm2

02p1.50C0PISOSPWP 2 7/0.53 0.6 1.25 20.8 959

04p1.50C0PISOSPWP 4 7/0.53 0.6 1.6 24.0 1218

06p1.50C0PISOSPWP 6 7/0.53 0.6 1.6 25.6 1538

10p1.50C0PISOSPWP 10 7/0.53 0.6 1.6 32.2 2357

15p1.50C0PISOSPWP 15 7/0.53 0.6 2.0 37.7 3006

20p1.50C0PISOSPWP 20 7/0.53 0.6 2.0 41.5 4040

Multi Pair Instrument Cables, Armoured,Individual & Overall Shielded

Page 79: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

78 BICC CABLES

Product Code No. of Pairs

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 2.0 mm2

02p2.00C0PISOSPWP 2 7/0.60 0.6 1.6 22.5 1070

04p2.00C0PISOSPWP 4 7/0.60 0.6 1.6 25.6 1377

06p2.00C0PISOSPWP 6 7/0.60 0.6 1.6 27.4 1703

10p2.00C0PISOSPWP 10 7/0.60 0.6 2.0 35.3 2724

15p2.00C0PISOSPWP 15 7/0.60 0.6 2.0 40.3 3900

20p2.00C0PISOSPWP 20 7/0.60 0.6 2.5 45.6 4738

Conductor 2.5 mm2

02p2.50C0PISOSPWP 2 7/0.67 0.6 1.6 23.0 1101

04p2.50C0PISOSPWP 4 7/0.67 0.6 1.6 26.2 1446

06p2.50C0PISOSPWP 6 7/0.67 0.6 1.6 28.2 1840

10p2.50C0PISOSPWP 10 7/0.67 0.6 2.0 36.3 2964

15p2.50C0PISOSPWP 15 7/0.67 0.6 2.0 41.5 3700

20p2.50C0PISOSPWP 20 7/0.67 0.6 2.5 47.4 5022

Follow: Multi Pair Instrument Cables, Armoured,Individual & Overall Shielded

Multi Triple Instrument Cables, Armoured,Individual & Overall Shielded

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.5 mm2

02t00.5C0PISOSPWP 2 7/0.30 0.6 1.25 18.2 666

04t00.5C0PISOSPWP 4 7/0.30 0.6 1.25 18.4 957

06t00.5C0PISOSPWP 6 7/0.30 0.6 1.6 22.1 1181

10t00.5C0PISOSPWP 10 7/0.30 0.6 1.6 27.4 1683

12t00.5C0PISOSPWP 12 7/0.30 0.6 1.6 28.1 1802

15t00.5C0PISOSPWP 15 7/0.30 0.6 1.6 31.1 2286

Conductor 0.75 mm2

02t0.75C0PISOSPWP 2 7/0.37 0.6 1.25 19.0 743

04t0.75C0PISOSPWP 4 7/0.37 0.6 1.25 20.0 1078

4.0 Instrument Cables

Page 80: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

79

Follow: Multi Triple Instrument Cables, Armoured,Individual & Overall Shielded

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 0.75 mm2

06t0.75C0PISOSPWP 6 7/0.37 0.6 1.6 23.0 1374

10t0.75C0PISOSPWP 10 7/0.37 0.6 1.6 28.9 2105

12t0.75C0PISOSPWP 12 7/0.37 0.6 1.6 29.8 2290

15t0.75C0PISOSPWP 15 7/0.37 0.6 2.0 33.9 2658

Conductor 1.0 mm2

02t1.00C0PISOSPWP 2 7/0.43 0.6 1.25 20.6 790

04t1.00C0PISOSPWP 4 7/0.43 0.6 1.25 22.0 1176

06t1.00C0PISOSPWP 6 7/0.43 0.6 1.6 25.2 1503

10t1.00C0PISOSPWP 10 7/0.43 0.6 1.6 32.0 2342

12t1.00C0PISOSPWP 12 7/0.43 0.6 2.0 33.7 2538

15t1.00C0PISOSPWP 15 7/0.43 0.6 2.0 37.4 2971

Conductor 1.5 mm2

02t1.50C0PISOSPWP 2 7/0.53 0.6 1.6 22.3 1041

04t1.50C0PISOSPWP 4 7/0.53 0.6 1.6 23.5 1372

06t1.50C0PISOSPWP 6 7/0.53 0.6 1.6 26.9 1787

10t1.50C0PISOSPWP 10 7/0.53 0.6 2.0 34.7 2758

12t1.50C0PISOSPWP 12 7/0.53 0.6 2.0 36.0 3021

15t1.50C0PISOSPWP 15 7/0.53 0.6 2.0 39.7 3941

Conductor 2.0 mm2

02t2.00C0PISOSPWP 2 7/0.60 0.6 1.6 23.6 1186

04t2.00C0PISOSPWP 4 7/0.60 0.6 1.6 24.5 1578

06t2.00C0PISOSPWP 6 7/0.60 0.6 1.6 28.8 2088

10t2.00C0PISOSPWP 10 7/0.60 0.6 2.0 37.6 3375

12t2.00C0PISOSPWP 12 7/0.60 0.6 2.0 38.7 3654

15t2.00C0PISOSPWP 15 7/0.60 0.6 2.0 42.5 4274

Conductor 2.5 mm2

02t2.50C0PISOSPWP 2 7/0.67 0.6 1.6 24.2 1209

04t2.50C0PISOSPWP 4 7/0.67 0.6 1.6 25.2 1622

06t2.50C0PISOSPWP 6 7/0.67 0.6 1.6 29.7 2186

10t2.50C0PISOSPWP 10 7/0.67 0.6 2.0 38.7 3505

12t2.50C0PISOSPWP 12 7/0.67 0.6 2.0 39.8 3912

15t2.50C0PISOSPWP 15 7/0.67 0.6 2.5 45.1 4572

Page 81: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

80 BICC CABLES

5.0 Earthing & Building Wires

Page 82: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

81

5.0 Earthing & Building Wires

Page 83: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

82 BICC CABLES

5.0 Earthing & Building Wires

Application

Sizes

Insulation Color

Rated Voltage

Construction

Specification Standards

Earthing wires are used for indoor fixed installations in dry locations, laid in conduits as well as in steel support brackets mainly inside appliances, switchgear and control gear.

This publication covers single core wires from conductor size 1 mm2 up to 10 mm2.

Yellow / Green is the most common used color for such wires and all other colorsare available upon request.

450/750 V

1. ConductorCopper (or Tinned Copper)In different flexibility degrees

2. Insulation- Polyvinyl Chloride (PVC) 70°C- Low Smoke Zero Halogen (LSOH) 90°C

Standard specification applied to PVC insulation

Standard specification applied to LSOH insulation

Standard specification applied to Conductor

Spread of Flame

IEC 60227-3 BS EN 50525-3-41

IEC 60228

Flame retardant as per IEC 60332-1

Note: Values in the following tables are approximate and subject to manufacturing tolerance.

Page 84: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

83

Bringing energy to your door

Page 85: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

84 BICC CABLES

5.0 Earthing & Building Wires

Earthing / Building Wires ApplicationThese wires are used for indoor fixed installations in dry locations, laid in conduits as well as in steel support brackets mainly inside appliances, switchgear and control gear.

Construction

1. ConductorStranded Copper class 2

2. InsulationPolyvinyl Chloride (PVC)Alternative: Low Smoke Zero Halogen (LSOH)

Page 86: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

85

Single Core PVC Insulated Conductor (450/750 V)

Single Core LSOH Insulated Conductor (450/750 V)

Product Code Conductor Area (mm2)

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

01c001CP0000 1.0 7/0.43 0.7 2.7 16

01c01.5CP0000 1.5 7/0.53 0.7 2.8 21

01c002CP0000 2.0 7/0.60 0.8 3.4 28

01c02.5CP0000 2.5 7/0.67 0.8 3.5 33

01c003CP0000 3.0 7/0.74 0.8 3.7 38

01c004CP0000 4.0 7/0.84 0.8 4.1 48

01c006CP0000 6.0 7/1.04 0.8 4.6 68

01c010CP0000 10.0 7/1.36 1 5.8 110

Product Code Conductor Area (mm2)

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

01c001CL0000 1.0 7/0.43 0.7 2.7 16

01c01.5CL0000 1.5 7/0.53 0.7 2.8 21

01c002CL0000 2.0 7/0.60 0.8 3.4 28

01c02.5CL0000 2.5 7/0.67 0.8 3.5 33

01c003CL0000 3.0 7/0.74 0.8 3.7 38

01c004CL0000 4.0 7/0.84 0.8 4.1 48

01c006CL0000 6.0 7/1.04 0.8 4.6 68

01c010CL0000 10.0 7/1.36 1 5.8 110

Page 87: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

86 BICC CABLES

6.0 Fire Resistance Control & Instrument Cables

Page 88: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

87

Page 89: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

88 BICC CABLES

Application

Construction

Fire resistance cables are used when the cables are required to keep circuit integrity and continue to operate in the presence of a fire for a specified time under defined conditions.

1. ConductorCopper (in variable classes 1,2&5)Tinned Copper is also available.

2. Fire resistance materialMICA Glass Tape

3. Insulation- Cross Linked Polyethylene (XLPE)- Low Smoke Zero Halogen (LSOH): For required controlled emissions of halogen and smoke

4. Bedding & Outer Sheath materialMaterial shall be compatible with the required function from these cables such as Low Smoke Zero Halogen(LSOH)

Spread Of Flame Spread of Flame

Circuit Integrity

Flame retardant as per IEC 60332-1 Fire resistance cable with glass mica tape 950°C in accordance with BS 6387 (category C,W & Z) and IEC 60331

These cables can be designed complete with Galvanized Steel Wire Armour and individual & Overall Shielding similar to categories illustrated in this publication.

6.0 Fire Resistance Control & Instrument Cables

Page 90: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

89

Options AvailableSizesAll sizes are available upon request

MaterialWhere necessary, special features can be incorporated into the cable enabling it to have:- Improved fire performance- Low smoke and fume (Halogen free)* IEC 60754-1&2 : Test on gas evolved during the combustion of material from cables* IEC 61034: Measurement of smoke density for cables burning under defined conditions- Termite resistance- Resistance to attack from oils, solvents or corrosive chemicals

Note: Values in the following tables are approximate and subject to manufacturing tolerance.

Page 91: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

90 BICC CABLES

Fire Resistance Control Cables,Non Armoured ApplicationThese cables are used for interconnecting control devices mainly in hazardous areas wheresafety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire resistance material MICA Glass Tape

3. InsulationCross Linked Polyethylene (XLPE)

4. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 92: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

91

Fire Resistance Control Cables, Non Armoured, XLPE Insulated

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Di-ameter (mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 1.0 mm2

02c001CMX00L 2 7/0.43 0.7 10.6 180

03c001CMX00L 3 7/0.43 0.7 11.1 190

04c001CMX00L 4 7/0.43 0.7 12.0 208

07c001CMX00L 7 7/0.43 0.7 13.9 280

12c001CMX00L 12 7/0.43 0.7 17.7 406

19c001CMX00L 19 7/0.43 0.7 20.4 546

27c001CMX00L 27 7/0.43 0.7 24.1 710

37c001CMX00L 37 7/0.43 0.7 26.9 886

48c001CMX00L 48 7/0.43 0.7 31.1 1110

Conductor 1.5 mm2

02c01.5CMX00L 2 7/0.53 0.7 11.1 200

03c01.5CMX00L 3 7/0.53 0.7 11.6 220

04c01.5CMX00L 4 7/0.53 0.7 12.5 241

07c01.5CMX00L 7 7/0.53 0.7 14.6 333

12c01.5CMX00L 12 7/0.53 0.7 18.6 495

19c01.5CMX00L 19 7/0.53 0.7 21.6 680

27c01.5CMX00L 27 7/0.53 0.7 25.6 895

37c01.5CMX00L 37 7/0.53 0.7 28.5 1137

48c01.5CMX00L 48 7/0.53 0.7 32.5 1431

Conductor 2.0 mm2

02c002CMX00L 2 7/0.60 0.7 11.6 230

03c002CMX00L 3 7/0.60 0.7 12.2 245

04c002CMX00L 4 7/0.60 0.7 13.2 277

07c002CMX00L 7 7/0.60 0.7 15.4 390

12c002CMX00L 12 7/0.60 0.7 19.7 585

19c002CMX00L 19 7/0.60 0.7 22.9 815

27c002CMX00L 27 7/0.60 0.7 27.2 1079

37c002CMX00L 37 7/0.60 0.7 30.6 1383

48c002CMX00L 48 7/0.60 0.7 35.3 1752

Page 93: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

92 BICC CABLES

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 2.5 mm2

02c02.5CMX00L 2 7/0.67 0.7 11.9 260

03c02.5CMX00L 3 7/0.67 0.7 12.5 270

04c02.5CMX00L 4 7/0.67 0.7 13.5 308

07c02.5CMX00L 7 7/0.67 0.7 15.7 441

12c02.5CMX00L 12 7/0.67 0.7 20.2 667

19c02.5CMX00L 19 7/0.67 0.7 23.5 938

27c02.5CMX00L 27 7/0.67 0.7 28.2 1261

37c02.5CMX00L 37 7/0.67 0.7 31.7 1622

48c02.5CMX00L 48 7/0.67 0.7 36.3 2057

Conductor 3.0 mm2

02c003CMX00L 2 7/0.74 0.7 12.3 280

03c003CMX00L 3 7/0.74 0.7 13.0 295

04c003CMX00L 4 7/0.74 0.7 14.0 339

07c003CMX00L 7 7/0.74 0.7 16.4 489

12c003CMX00L 12 7/0.74 0.7 21.2 748

19c003CMX00L 19 7/0.74 0.7 24.6 1062

27c003CMX00L 27 7/0.74 0.7 29.5 1426

37c003CMX00L 37 7/0.74 0.7 33.2 1846

Conductor 4.0 mm2

02c004CMX00L 2 7/0.84 0.7 13.1 321

03c004CMX00L 3 7/0.84 0.7 13.8 330

04c004CMX00L 4 7/0.84 0.7 14.9 393

07c004CMX00L 7 7/0.84 0.7 17.5 577

12c004CMX00L 12 7/0.84 0.7 22.7 893

19c004CMX00L 19 7/0.84 0.7 26.5 1283

27c004CMX00L 27 7/0.84 0.7 32.1 1728

37c004CMX00L 37 7/0.84 0.7 36.1 2274

Follow: Fire Resistance Control Cables, Non Armoured, XLPE Insulated

6.0 Fire Resistance Control & Instrument Cables

Page 94: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

93

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 6.0 mm2

02c006CMX00L 2 7/1.04 0.7 14.1 376

03c006CMX00L 3 7/1.04 0.7 14.9 400

04c006CMX00L 4 7/1.04 0.7 16.2 488

Conductor 10 mm2

02c010CMX00L 2 7/1.36 0.7 15.7 498

03c010CMX00L 3 7/1.36 0.7 16.6 559

04c010CMX00L 4 7/1.36 0.7 18.1 693

Follow: Fire Resistance Control Cables, Non Armoured, XLPE Insulated

Page 95: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

94 BICC CABLES

Fire Resistance Control Cables,Armoured ApplicationThese cables are used for interconnecting control devices mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire Resistance Material MICA Glass Tape

3. InsulationCross Linked Polyethylene (XLPE)

4. Armour Galvanized Round Steel Wire (GSWA)

5. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 96: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

95

Fire Resistance Control Cables, Armoured, XLPE Insulated

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.0 mm2

02c001CMXLWL 2 7/0.43 0.7 0.9 14.9 424

03c001CMXLWL 3 7/0.43 0.7 0.9 15.4 435

04c001CMXLWL 4 7/0.43 0.7 1.25 17.0 479

07c001CMXLWL 7 7/0.43 0.7 1.25 18.9 676

12c001CMXLWL 12 7/0.43 0.7 1.6 23.4 915

19c001CMXLWL 19 7/0.43 0.7 1.6 26.1 1263

27c001CMXLWL 27 7/0.43 0.7 1.6 30.0 1569

37c001CMXLWL 37 7/0.43 0.7 2.0 33.8 1864

48c001CMXLWL 48 7/0.43 0.7 2.0 38.0 2248

Conductor 1.5 mm2

02c01.5CMXLWL 2 7/0.53 0.7 0.9 15.4 473

03c01.5CMXLWL 3 7/0.53 0.7 0.9 15.9 484

04c01.5CMXLWL 4 7/0.53 0.7 1.25 17.5 540

07c01.5CMXLWL 7 7/0.53 0.7 1.25 19.6 773

12c01.5CMXLWL 12 7/0.53 0.7 1.6 24.3 1050

19c01.5CMXLWL 19 7/0.53 0.7 1.6 27.3 1473

27c01.5CMXLWL 27 7/0.53 0.7 1.6 31.7 1849

37c01.5CMXLWL 37 7/0.53 0.7 2.0 35.6 2236

48c01.5CMXLWL 48 7/0.53 0.7 2.0 39.8 2909

Conductor 2.0 mm2

02c002CMXLWL 2 7/0.60 0.7 0.9 15.9 498

03c002CMXLWL 3 7/0.60 0.7 1.25 17.2 520

04c002CMXLWL 4 7/0.60 0.7 1.25 18.2 670

07c002CMXLWL 7 7/0.60 0.7 1.25 20.4 844

12c002CMXLWL 12 7/0.60 0.7 1.6 25.4 1300

19c002CMXLWL 19 7/0.60 0.7 1.6 28.8 1671

27c002CMXLWL 27 7/0.60 0.7 2.0 34.3 2102

37c002CMXLWL 37 7/0.60 0.7 2.0 37.7 2554

48c002CMXLWL 48 7/0.60 0.7 2.0 42.2 3554

Page 97: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

96 BICC CABLES

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter

(mm)

Overall Cable Diameter

(mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 2.5 mm2

02c02.5CMXLWL 2 7/0.67 0.7 1.25 16.9 526

03c02.5CMXLWL 3 7/0.67 0.7 1.25 17.5 553

04c02.5CMXLWL 4 7/0.67 0.7 1.25 18.5 717

07c02.5CMXLWL 7 7/0.67 0.7 1.25 20.9 920

12c02.5CMXLWL 12 7/0.67 0.7 1.6 25.9 1428

19c02.5CMXLWL 19 7/0.67 0.7 1.6 29.4 1841

27c02.5CMXLWL 27 7/0.67 0.7 2.0 35.0 2336

37c02.5CMXLWL 37 7/0.67 0.7 2.0 38.6 3145

48c02.5CMXLWL 48 7/0.67 0.7 2.0 43.3 3929

Conductor 3.0 mm2

02c003CMXLWL 2 7/0.74 0.7 1.25 17.3 552

03c003CMXLWL 3 7/0.74 0.7 1.25 18.0 676

04c003CMXLWL 4 7/0.74 0.7 1.25 19.0 760

07c003CMXLWL 7 7/0.74 0.7 1.25 21.4 985

12c003CMXLWL 12 7/0.74 0.7 1.6 26.9 1534

19c003CMXLWL 19 7/0.74 0.7 1.6 30.6 1994

27c003CMXLWL 27 7/0.74 0.7 2.0 36.9 2584

37c003CMXLWL 37 7/0.74 0.7 2.0 40.2 3463

Conductor 4.0 mm2

02c004CMXLWL 2 7/0.84 0.7 1.25 18.1 694

03c004CMXLWL 3 7/0.84 0.7 1.25 18.8 748

04c004CMXLWL 4 7/0.84 0.7 1.25 19.9 845

07c004CMXLWL 7 7/0.84 0.7 1.6 23.2 1115

12c004CMXLWL 12 7/0.84 0.7 1.6 28.6 1746

19c004CMXLWL 19 7/0.84 0.7 1.6 32.6 2301

27c004CMXLWL 27 7/0.84 0.7 2.0 39.0 3269

37c004CMXLWL 37 7/0.84 0.7 2.0 43.0 4095

Follow: Fire Resistance Control Cables, Armoured, XLPE Insulated

6.0 Fire Resistance Control & Instrument Cables

Page 98: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

97

Product Code No. of Cores

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter

(mm)

Overall Cable Diameter

(mm)

Approx. Weight of Completed Cable (kg/km)

Conductor 6.0 mm2

02c006CMXLWL 2 7/1.04 0.7 1.25 19.1 744

03c006CMXLWL 3 7/1.04 0.7 1.25 19.9 805

04c006CMXLWL 4 7/1.04 0.7 1.25 21.2 928

Conductor 10 mm2

02c010CMXLWL 2 7/1.36 0.7 1.25 20.7 910

03c010CMXLWL 3 7/1.36 0.7 1.25 21.6 1022

04c010CMXLWL 4 7/1.36 0.7 1.6 23.8 1205

Follow: Fire Resistance Control Cables, Armoured, XLPE Insulated

Page 99: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

98 BICC CABLES

Fire Resistance Multi Pair/Triple & Core Cables, Non Armoured, XLPE Insulated, Overall Shielding ApplicationThese cables are used as signal carrier for connecting electrical instrument circuits mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire Resistance Material MICA Glass Tape

3. InsulationCross Linked Polyethylene (XLPE)

4. Shielding Overall Shielding

5. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 100: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

99

Fire Resistance Multi Pair Cables, Non Armoured, Overall Shielded, XLPE Insulated

Product Code No. of Pairs Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diame-ter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01p01.5CMXOS000L 1 7/0.53 0.6 9.0 115

02p01.5CMXOS000L 2 7/0.53 0.6 16.6 183

04p01.5CMXOS000L 4 7/0.53 0.6 19.6 376

06p01.5CMXOS000L 6 7/0.53 0.6 21.5 508

10p01.5CMXOS000L 10 7/0.53 0.6 29.1 749

15p01.5CMXOS000L 15 7/0.53 0.6 33.9 1094

20p01.5CMXOS000L 20 7/0.53 0.6 38.7 1430

Conductor 2.5 mm2

01p02.5CMXOS000L 1 7/0.67 0.6 9.8 154

02p02.5CMXOS000L 2 7/0.67 0.6 18.1 256

04p02.5CMXOS000L 4 7/0.67 0.6 21.5 514

06p02.5CMXOS000L 6 7/0.67 0.6 24.3 725

10p02.5CMXOS000L 10 7/0.67 0.6 32.2 1145

15p02.5CMXOS000L 15 7/0.67 0.6 38.1 1644

20p02.5CMXOS000L 20 7/0.67 0.6 43.3 2169

Page 101: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

100 BICC CABLES

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01t01.5CMXOS000L 1 7/0.53 0.6 9.5 146

02t01.5CMXOS000L 2 7/0.53 0.6 17.6 286

04t01.5CMXOS000L 4 7/0.53 0.6 18.9 490

06t01.5CMXOS000L 6 7/0.53 0.6 23.5 688

10t01.5CMXOS000L 10 7/0.53 0.6 31.2 1050

12t01.5CMXOS000L 12 7/0.53 0.6 32.4 1225

15t01.5CMXOS000L 15 7/0.53 0.6 36.9 1529

Conductor 2.5 mm2

01t02.5CMXOS000L 1 7/0.67 0.6 10.3 188

02t02.5CMXOS000L 2 7/0.67 0.6 19.5 350

04t02.5CMXOS000L 4 7/0.67 0.6 20.9 663

06t02.5CMXOS000L 6 7/0.67 0.6 26.0 950

10t02.5CMXOS000L 10 7/0.67 0.6 35.2 1521

12t02.5CMXOS000L 12 7/0.67 0.6 36.5 1760

15t02.5CMXOS000L 15 7/0.67 0.6 40.9 2199

6.0 Fire Resistance Control & Instrument Cables

Fire Resistance Multi Triple Cables, Non Armoured, Overall Shielded, XLPE Insulated

Page 102: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

101

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02c01.5CMXOS000L 2 7/0.53 0.6 9.0 115

03c01.5CMXOS000L 3 7/0.53 0.6 9.5 153

04c01.5CMXOS000L 4 7/0.53 0.6 10.4 185

05c01.5CMXOS000L 5 7/0.53 0.6 11.7 219

07c01.5CMXOS000L 7 7/0.53 0.6 12.7 296

12c01.5CMXOS000L 12 7/0.53 0.6 16.7 471

19c01.5CMXOS000L 19 7/0.53 0.6 19.7 674

24c01.5CMXOS000L 24 7/0.53 0.6 23.3 851

Conductor 2.5 mm2

02c02.5CMXOS000L 2 7/0.67 0.6 9.8 161

03c02.5CMXOS000L 3 7/0.67 0.6 10.3 199

04c02.5CMXOS000L 4 7/0.67 0.6 11.7 245

05c02.5CMXOS000L 5 7/0.67 0.6 12.7 310

07c02.5CMXOS000L 7 7/0.67 0.6 14.0 396

12c02.5CMXOS000L 12 7/0.67 0.6 18.5 631

19c02.5CMXOS000L 19 7/0.67 0.6 21.6 939

24c02.5CMXOS000L 24 7/0.67 0.6 25.7 1201

Fire Resistance Multi Core Cables, Non Armoured, Overall Shielded, XLPE Insulated

Page 103: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

102 BICC CABLES

Fire Resistance Multi Pair/Triple Cables, Non Armoured, XLPE Insulated, Individual & Overall Shielding ApplicationThese cables are used as signal carrier for connecting electrical instrument circuits mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire resistance material MICA Glass Tape

3. InsulationCross Linked Polyethylene (XLPE)

4. Shielding Individual & Overall Shielding

5. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 104: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

103

Fire Resistance Multi Pair Cables, Non Armoured,Individual & Overall Shielded, XLPE Insulated

Fire Resistance Multi Triple Cables,Non Armoured, Individual & Overall Shielded, XLPE Insulated

Product Code No. of Pairs Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02p01.5CMXISOS00L 2 7/0.53 0.6 17.0 300

04p01.5CMXISOS00L 4 7/0.53 0.6 20.1 459

06p01.5CMXISOS00L 6 7/0.53 0.6 22.1 648

10p01.5CMXISOS00L 10 7/0.53 0.6 29.9 983

15p01.5CMXISOS00L 15 7/0.53 0.6 35.4 1403

20p01.5CMXISOS00L 20 7/0.53 0.6 39.8 1853

Conductor 2.5 mm2

02p02.5CMXISOS00L 2 7/0.67 0.6 18.5 388

04p02.5CMXISOS00L 4 7/0.67 0.6 22.0 619

06p02.5CMXISOS00L 6 7/0.67 0.6 24.9 861

10p02.5CMXISOS00L 10 7/0.67 0.6 33.0 1429

15p02.5CMXISOS00L 15 7/0.67 0.6 39.1 1956

20p02.5CMXISOS00L 20 7/0.67 0.6 44.4 2590

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02t01.5CMXISOS00L 2 7/0.53 0.6 18.0 345

04t01.5CMXISOS00L 4 7/0.53 0.6 19.4 550

06t01.5CMXISOS00L 6 7/0.53 0.6 24.1 813

10t01.5CMXISOS00L 10 7/0.53 0.6 32.0 1238

12t01.5CMXISOS00L 12 7/0.53 0.6 33.2 1478

15t01.5CMXISOS00L 15 7/0.53 0.6 37.9 1788

Conductor 2.5 mm2

02t02.5CMXISOS00L 2 7/0.67 0.6 19.9 458

04t02.5CMXISOS00L 4 7/0.67 0.6 21.4 751

06t02.5CMXISOS00L 6 7/0.67 0.6 26.4 1058

10t02.5CMXISOS00L 10 7/0.67 0.6 36.0 1758

12t02.5CMXISOS00L 12 7/0.67 0.6 37.3 2003

15t02.5CMXISOS00L 15 7/0.67 0.6 42.2 2440

Page 105: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

104 BICC CABLES

Fire Resistance Multi Pair/Triple & Multi Core Cables, Armoured, XLPE Insulated, Overall Shielding ApplicationThese cables are used as signal carrier for connecting electrical instrument circuits mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire resistance material MICA Glass Tape

3. InsulationCross Linked Polyethylene (XLPE)

4. Shielding Overall Shielding

5. ArmourGalvanized Round Steel Wire (GSWA)

6. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 106: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

105

Fire Resistance Multi Pair Cables, Armoured, Overall Shielded,XLPE Insulated

Product Code No. of Pairs Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter

(mm)

Overall Cable Diameter

(mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01p01.5CMXOS0LWL 1 7/0.53 0.6 0.9 14.1 434

02p01.5CMXOS0LWL 2 7/0.53 0.6 1.25 22.8 648

04p01.5CMXOS0LWL 4 7/0.53 0.6 1.6 26.7 1261

06p01.5CMXOS0LWL 6 7/0.53 0.6 1.6 28.8 1539

10p01.5CMXOS0LWL 10 7/0.53 0.6 2.0 37.6 2029

15p01.5CMXOS0LWL 15 7/0.53 0.6 2.0 42.6 2965

20p01.5CMXOS0LWL 20 7/0.53 0.6 2.5 48.5 3541

Conductor 2.5 mm2

01p02.5CMXOS0LWL 1 7/0.67 0.6 0.9 14.9 504

02p02.5CMXOS0LWL 2 7/0.67 0.6 1.6 25.2 768

04p02.5CMXOS0LWL 4 7/0.67 0.6 1.6 28.8 1525

06p02.5CMXOS0LWL 6 7/0.67 0.6 1.6 31.8 1896

10p02.5CMXOS0LWL 10 7/0.67 0.6 2.0 40.9 2913

15p02.5CMXOS0LWL 15 7/0.67 0.6 2.5 47.9 3810

20p02.5CMXOS0LWL 20 7/0.67 0.6 2.5 53.1 5093

Page 107: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

106 BICC CABLES

Fire Resistance Multi Triple Cables, Armoured, Overall Shielded,XLPE Insulated

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire

Diameter (mm)

Overall Cable Diameter

(mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01t01.5CMXOS0LWL 1 7/0.53 0.6 0.9 14.6 488

02t01.5CMXOS0LWL 2 7/0.53 0.6 1.6 24.7 913

04t01.5CMXOS0LWL 4 7/0.53 0.6 1.6 26.0 1475

06t01.5CMXOS0LWL 6 7/0.53 0.6 1.6 30.8 1838

10t01.5CMXOS0LWL 10 7/0.53 0.6 2.0 39.7 2798

12t01.5CMXOS0LWL 12 7/0.53 0.6 2.0 41.1 3121

15t01.5CMXOS0LWL 15 7/0.53 0.6 2.5 46.3 3641

Conductor 2.5 mm2

01t02.5CMXOS0LWL 1 7/0.67 0.6 1.25 16.1 550

02t02.5CMXOS0LWL 2 7/0.67 0.6 1.6 26.6 1005

04t02.5CMXOS0LWL 4 7/0.67 0.6 1.6 28.2 1771

06t02.5CMXOS0LWL 6 7/0.67 0.6 2.0 34.3 2241

10t02.5CMXOS0LWL 10 7/0.67 0.6 2.5 44.6 3488

12t02.5CMXOS0LWL 12 7/0.67 0.6 2.5 45.9 3899

15t02.5CMXOS0LWL 15 7/0.67 0.6 2.5 50.7 4583

6.0 Fire Resistance Control & Instrument Cables

Page 108: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

107

Fire Resistance Multi Core Cables, Armoured, Overall Shielded,XLPE Insulated

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02c01.5CMXOS0LWL 2 7/0.53 0.6 0.9 14.1 434

03c01.5CMXOS0LWL 3 7/0.53 0.6 0.9 14.6 494

04c01.5CMXOS0LWL 4 7/0.53 0.6 1.25 16.2 650

05c01.5CMXOS0LWL 5 7/0.53 0.6 1.25 17.7 718

07c01.5CMXOS0LWL 7 7/0.53 0.6 1.25 18.7 863

12c01.5CMXOS0LWL 12 7/0.53 0.6 1.6 23.8 1356

19c01.5CMXOS0LWL 19 7/0.53 0.6 1.6 26.8 1705

24c01.5CMXOS0LWL 24 7/0.53 0.6 1.6 30.6 2048

Conductor 2.5 mm2

02c02.5CMXOS0LWL 2 7/0.67 0.6 0.9 14.9 518

03c02.5CMXOS0LWL 3 7/0.67 0.6 1.25 16.1 674

04c02.5CMXOS0LWL 4 7/0.67 0.6 1.25 17.7 755

05c02.5CMXOS0LWL 5 7/0.67 0.6 1.25 18.7 891

07c02.5CMXOS0LWL 7 7/0.67 0.6 1.25 20.2 1020

12c02.5CMXOS0LWL 12 7/0.67 0.6 1.6 25.6 1641

19c02.5CMXOS0LWL 19 7/0.67 0.6 1.6 28.9 2111

24c02.5CMXOS0LWL 24 7/0.67 0.6 2.0 34.0 2595

Page 109: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

108 BICC CABLES

Fire Resistance Multi Pair/Triple Cables, Armoured,XLPE Insulated, Individual & Overall Shielding ApplicationThese cables are used as signal carrier for connecting electrical instrument circuits mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire resistance material MICA Glass Tape

3. InsulationCross Linked Polyethylene (XLPE)

4. Shielding Individual & Overall Shielding

5. ArmourGalvanized Round Steel Wire (GSWA)

6. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 110: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

109

Fire Resistance Multi Pair Cables, Armoured,Individual & Overall Shielded, XLPE Insulated

Fire Resistance Multi Triple Cables, Armoured,Individual & Overall Shielded , XLPE Insulated

Product Code No. of Pairs

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02p01.5CMXISOSLWL 2 7/0.53 0.6 1.6 24.1 1181

04p01.5CMXISOSLWL 4 7/0.53 0.6 1.6 27.4 1490

06p01.5CMXISOSLWL 6 7/0.53 0.6 1.6 29.4 1873

10p01.5CMXISOSLWL 10 7/0.53 0.6 2.0 38.4 2863

15p01.5CMXISOSLWL 15 7/0.53 0.6 2.5 44.8 3633

20p01.5CMXISOSLWL 20 7/0.53 0.6 2.5 49.6 4883

Conductor 2.5 mm2

02p02.5CMXISOSLWL 2 7/0.67 0.6 1.6 25.6 1356

04p02.5CMXISOSLWL 4 7/0.67 0.6 1.6 29.3 1769

06p02.5CMXISOSLWL 6 7/0.67 0.6 1.6 32.4 2241

10p02.5CMXISOSLWL 10 7/0.67 0.6 2.0 41.7 3608

15p02.5CMXISOSLWL 15 7/0.67 0.6 2.5 48.9 4479

20p02.5CMXISOSLWL 20 7/0.67 0.6 2.5 54.4 6081

Product Code No. of Triples

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02t01.5CMXISOSLWL 2 7/0.53 0.6 1.6 25.1 1276

04t01.5CMXISOSLWL 4 7/0.53 0.6 1.6 26.5 1663

06t01.5CMXISOSLWL 6 7/0.53 0.6 1.6 31.6 2160

10t01.5CMXISOSLWL 10 7/0.53 0.6 2.0 40.7 3324

12t01.5CMXISOSLWL 12 7/0.53 0.6 2.0 41.9 3629

15t01.5CMXISOSLWL 15 7/0.53 0.6 2.5 47.7 4625

Conductor 2.5 mm2

02t02.5CMXISOSLWL 2 7/0.67 0.6 1.6 27.2 1481

04t02.5CMXISOSLWL 4 7/0.67 0.6 1.6 28.7 1963

06t02.5CMXISOSLWL 6 7/0.67 0.6 2.0 35.1 2523

10t02.5CMXISOSLWL 10 7/0.67 0.6 2.5 45.4 4075

12t02.5CMXISOSLWL 12 7/0.67 0.6 2.5 47.1 4394

15t02.5CMXISOSLWL 15 7/0.67 0.6 2.5 52.0 5125

Page 111: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

110 BICC CABLES

Fire Resistance Multi Pair/Triple & Cores Cables, Non Armoured, LSOH Insulated, Overall Shielding ApplicationThese cables are used as signal carrier for connecting electrical instrument circuits mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire resistance material MICA Glass Tape

3. InsulationLow Smoke Zero Halogen (LSOH)

4. Shielding Overall Shielding

5. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 112: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

111

Fire Resistance Multi Pair Cables, Non Armoured, Overall Shielded, LSOH Insulated

Product Code No. of Pairs Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01p01.5CMLOS000L 1 7/0.53 0.6 9.0 124

02p01.5CMLOS000L 2 7/0.53 0.6 16.6 199

04p01.5CMLOS000L 4 7/0.53 0.6 19.6 410

06p01.5CMLOS000L 6 7/0.53 0.6 21.5 556

10p01.5CMLOS000L 10 7/0.53 0.6 29.1 831

15p01.5CMLOS000L 15 7/0.53 0.6 33.9 1219

20p01.5CMLOS000L 20 7/0.53 0.6 38.7 1595

Conductor 2.5 mm2

01p02.5CMLOS000L 1 7/0.67 0.6 9.8 164

02p02.5CMLOS000L 2 7/0.67 0.6 18.1 276

04p02.5CMLOS000L 4 7/0.67 0.6 21.5 554

06p02.5CMLOS000L 6 7/0.67 0.6 24.3 784

10p02.5CMLOS000L 10 7/0.67 0.6 32.2 1243

15p02.5CMLOS000L 15 7/0.67 0.6 38.1 1791

20p02.5CMLOS000L 20 7/0.67 0.6 43.3 2365

Page 113: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

112 BICC CABLES

Fire Resistance Multi Triple Cables, Non Armoured, Overall Shielded, LSOH Insulated

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01t01.5CMLOS000L 1 7/0.53 0.6 9.5 159

02t01.5CMLOS000L 2 7/0.53 0.6 17.6 311

04t01.5CMLOS000L 4 7/0.53 0.6 18.9 539

06t01.5CMLOS000L 6 7/0.53 0.6 23.5 765

10t01.5CMLOS000L 10 7/0.53 0.6 31.2 1175

12t01.5CMLOS000L 12 7/0.53 0.6 32.4 1374

15t01.5CMLOS000L 15 7/0.53 0.6 36.9 1715

Conductor 2.5 mm2

01t02.5CMLOS000L 1 7/0.67 0.6 10.3 203

02t02.5CMLOS000L 2 7/0.67 0.6 19.5 381

04t02.5CMLOS000L 4 7/0.67 0.6 20.9 723

06t02.5CMLOS000L 6 7/0.67 0.6 26.0 1038

10t02.5CMLOS000L 10 7/0.67 0.6 35.2 1668

12t02.5CMLOS000L 12 7/0.67 0.6 36.5 1935

15t02.5CMLOS000L 15 7/0.67 0.6 40.9 2416

6.0 Fire Resistance Control & Instrument Cables

Page 114: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

113

Fire Resistance Multi Core Cables, Non Armoured, Overall Shielded, LSOH Insulated

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02c01.5CMLOS000L 2 7/0.53 0.6 9.0 123

03c01.5CMLOS000L 3 7/0.53 0.6 9.5 165

04c01.5CMLOS000L 4 7/0.53 0.6 10.4 201

05c01.5CMLOS000L 5 7/0.53 0.6 11.7 239

07c01.5CMLOS000L 7 7/0.53 0.6 12.7 325

12c01.5CMLOS000L 12 7/0.53 0.6 16.7 521

19c01.5CMLOS000L 19 7/0.53 0.6 19.7 753

24c01.5CMLOS000L 24 7/0.53 0.6 23.3 951

Conductor 2.5 mm2

02c02.5CMLOS000L 2 7/0.67 0.6 9.8 170

03c02.5CMLOS000L 3 7/0.67 0.6 10.3 214

04c02.5CMLOS000L 4 7/0.67 0.6 11.7 264

05c02.5CMLOS000L 5 7/0.67 0.6 12.7 335

07c02.5CMLOS000L 7 7/0.67 0.6 14.0 430

12c02.5CMLOS000L 12 7/0.67 0.6 18.5 688

19c02.5CMLOS000L 19 7/0.67 0.6 21.6 1030

24c02.5CMLOS000L 24 7/0.67 0.6 25.7 1316

Page 115: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

114 BICC CABLES

Fire Resistance Multi Pair/Triple Cables, Non Armoured, LSOH Insulated, Individual & Overall Shielding ApplicationThese cables are used as signal carrier for connecting electrical instrument circuits mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire resistance material MICA Glass Tape

3. InsulationLow Smoke Zero Halogen (LSOH)

4. Shielding Individual & Overall Shielding

5. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 116: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

115

Fire Resistance Multi Pair Cables, Non Armoured,Individual & Overall Shielded, LSOH Insulated

Fire Resistance Multi Triple Cables, Non Armoured,Individual & Overall Shielded, LSOH Insulated

Product Code No. of Pairs Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02p01.5CMLISOS00L 2 7/0.53 0.6 17.0 316

04p01.5CMLISOS00L 4 7/0.53 0.6 20.1 493

06p01.5CMLISOS00L 6 7/0.53 0.6 22.1 698

10p01.5CMLISOS00L 10 7/0.53 0.6 29.9 1066

15p01.5CMLISOS00L 15 7/0.53 0.6 35.4 1528

20p01.5CMLISOS00L 20 7/0.53 0.6 39.8 2020

Conductor 2.5 mm2

02p02.5CMLISOS00L 2 7/0.67 0.6 18.5 406

04p02.5CMLISOS00L 4 7/0.67 0.6 22.0 658

06p02.5CMLISOS00L 6 7/0.67 0.6 24.9 920

10p02.5CMLISOS00L 10 7/0.67 0.6 33.0 1515

15p02.5CMLISOS00L 15 7/0.67 0.6 39.1 2104

20p02.5CMLISOS00L 20 7/0.67 0.6 44.4 2786

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02t01.5CMLISOS00L 2 7/0.53 0.6 18.0 370

04t01.5CMLISOS00L 4 7/0.53 0.6 19.4 611

06t01.5CMLISOS00L 6 7/0.53 0.6 24.1 890

10t01.5CMLISOS00L 10 7/0.53 0.6 32.0 1363

12t01.5CMLISOS00L 12 7/0.53 0.6 33.2 1625

15t01.5CMLISOS00L 15 7/0.53 0.6 37.9 1980

Conductor 2.5 mm2

02t02.5CMLISOS00L 2 7/0.67 0.6 19.9 486

04t02.5CMLISOS00L 4 7/0.67 0.6 21.4 810

06t02.5CMLISOS00L 6 7/0.67 0.6 26.4 1145

10t02.5CMLISOS00L 10 7/0.67 0.6 36.0 1904

12t02.5CMLISOS00L 12 7/0.67 0.6 37.3 2176

15t02.5CMLISOS00L 15 7/0.67 0.6 42.2 2659

Page 117: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

116 BICC CABLES

Fire Resistance Multi Pair/Triple & Core Cables, Armoured,LSOH Insulated, Overall ShieldingApplicationThese cables are used as signal carrier for connecting electrical instrument circuits mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire resistance material MICA Glass Tape

3. InsulationLow Smoke Zero Halogen (LSOH)

4. Shielding Overall Shielding

5. ArmourGalvanized Round Steel Wire (GSWA)

6. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 118: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

117

Fire Resistance Multi Pair Cables, Armoured, Overall Shielded,LSOH Insulated

Product Code No. of Pairs Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter

(mm)

Overall Cable Diameter

(mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01p01.5CMLOS0LWL 1 7/0.53 0.6 0.9 14.1 443

02p01.5CMLOS0LWL 2 7/0.53 0.6 1.25 22.8 665

04p01.5CMLOS0LWL 4 7/0.53 0.6 1.6 26.7 1295

06p01.5CMLOS0LWL 6 7/0.53 0.6 1.6 28.8 1589

10p01.5CMLOS0LWL 10 7/0.53 0.6 2.0 37.6 2111

15p01.5CMLOS0LWL 15 7/0.53 0.6 2.0 42.6 3034

20p01.5CMLOS0LWL 20 7/0.53 0.6 2.5 48.5 3711

Conductor 2.5 mm2

01p02.5CMLOS0LWL 1 7/0.67 0.6 0.9 14.9 513

02p02.5CMLOS0LWL 2 7/0.67 0.6 1.6 25.2 786

04p02.5CMLOS0LWL 4 7/0.67 0.6 1.6 28.8 1564

06p02.5CMLOS0LWL 6 7/0.67 0.6 1.6 31.8 1955

10p02.5CMLOS0LWL 10 7/0.67 0.6 2.0 40.9 3010

15p02.5CMLOS0LWL 15 7/0.67 0.6 2.5 47.9 3958

20p02.5CMLOS0LWL 20 7/0.67 0.6 2.5 53.1 5289

Page 119: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

118 BICC CABLES

Fire Resistance Multi Triple Cables, Armoured, Overall Shielded,LSOH Insulated

Product Code No. of Triples

Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire

Diameter (mm)

Overall Cable Diameter

(mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

01t01.5CMLOS0LWL 1 7/0.53 0.6 0.9 14.6 500

02t01.5CMLOS0LWL 2 7/0.53 0.6 1.6 24.7 943

04t01.5CMLOS0LWL 4 7/0.53 0.6 1.6 26.0 1525

06t01.5CMLOS0LWL 6 7/0.53 0.6 1.6 30.8 1910

10t01.5CMLOS0LWL 10 7/0.53 0.6 2.0 39.7 2921

12t01.5CMLOS0LWL 12 7/0.53 0.6 2.0 41.1 3270

15t01.5CMLOS0LWL 15 7/0.53 0.6 2.5 46.3 3826

Conductor 2.5 mm2

01t02.5CMLOS0LWL 1 7/0.67 0.6 1.25 16.1 569

02t02.5CMLOS0LWL 2 7/0.67 0.6 1.6 26.6 1035

04t02.5CMLOS0LWL 4 7/0.67 0.6 1.6 28.2 1829

06t02.5CMLOS0LWL 6 7/0.67 0.6 2.0 34.3 2329

10t02.5CMLOS0LWL 10 7/0.67 0.6 2.5 44.6 3634

12t02.5CMLOS0LWL 12 7/0.67 0.6 2.5 45.9 4074

15t02.5CMLOS0LWL 15 7/0.67 0.6 2.5 50.7 4800

6.0 Fire Resistance Control & Instrument Cables

Page 120: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

119

Fire Resistance Multi Core Cables, Armoured, Overall Shielded,LSOH Insulated

Product Code No. of Cores Strand No. / Diameter (mm)

Insulation Thickness

(mm)

Armour Wire Diameter

(mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02c01.5CMLOS0LWL 2 7/0.53 0.6 0.9 14.1 441

03c01.5CMLOS0LWL 3 7/0.53 0.6 0.9 14.6 506

04c01.5CMLOS0LWL 4 7/0.53 0.6 1.25 16.2 668

05c01.5CMLOS0LWL 5 7/0.53 0.6 1.25 17.7 739

07c01.5CMLOS0LWL 7 7/0.53 0.6 1.25 18.7 893

12c01.5CMLOS0LWL 12 7/0.53 0.6 1.6 23.8 1406

19c01.5CMLOS0LWL 19 7/0.53 0.6 1.6 26.8 1784

24c01.5CMLOS0LWL 24 7/0.53 0.6 1.6 30.6 2148

Conductor 2.5 mm2

02c02.5CMLOS0LWL 2 7/0.67 0.6 0.9 14.9 528

03c02.5CMLOS0LWL 3 7/0.67 0.6 1.25 16.1 688

04c02.5CMLOS0LWL 4 7/0.67 0.6 1.25 17.7 775

05c02.5CMLOS0LWL 5 7/0.67 0.6 1.25 18.7 915

07c02.5CMLOS0LWL 7 7/0.67 0.6 1.25 20.2 1054

12c02.5CMLOS0LWL 12 7/0.67 0.6 1.6 25.6 1699

19c02.5CMLOS0LWL 19 7/0.67 0.6 1.6 28.9 2203

24c02.5CMLOS0LWL 24 7/0.67 0.6 2.0 34.0 2710

Page 121: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

120 BICC CABLES

Fire Resistance Multi Pair/Triple Cables, Armoured LSOH Insulated, Individual & Overall Shielding ApplicationThese cables are used as signal carrier for connecting electrical instrument circuits mainly in hazardous areas where safety and circuit integrity are highly required during fire conditions.

Construction

1. ConductorStranded Copper class 2

2. Fire resistance material MICA Glass Tape

3. InsulationLow Smoke Zero Halogen (LSOH)

4. Shielding Individual & Overall Shielding 5. ArmourGalvanized Round Steel Wire (GSWA)

6. SheathLow Smoke Zero Halogen (LSOH)

6.0 Fire Resistance Control & Instrument Cables

Page 122: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

121

Fire Resistance Multi Pair Cables, Armoured,Individual & Overall Shielded, LSOH Insulated

Fire Resistance Multi Triple Cables, Armoured,Individual & Overall Shielded, LSOH Insulated

Product Code No. of Pairs

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02p01.5CMLISOSLWL 2 7/0.53 0.6 1.6 24.1 1199

04p01.5CMLISOSLWL 4 7/0.53 0.6 1.6 27.4 1523

06p01.5CMLISOSLWL 6 7/0.53 0.6 1.6 29.4 1923

10p01.5CMLISOSLWL 10 7/0.53 0.6 2.0 38.4 2946

15p01.5CMLISOSLWL 15 7/0.53 0.6 2.5 44.8 3758

20p01.5CMLISOSLWL 20 7/0.53 0.6 2.5 49.6 5050

Conductor 2.5 mm2

02p02.5CMLISOSLWL 2 7/0.67 0.6 1.6 25.6 1376

04p02.5CMLISOSLWL 4 7/0.67 0.6 1.6 29.3 1808

06p02.5CMLISOSLWL 6 7/0.67 0.6 1.6 32.4 2300

10p02.5CMLISOSLWL 10 7/0.67 0.6 2.0 41.7 3705

15p02.5CMLISOSLWL 15 7/0.67 0.6 2.5 48.9 4625

20p02.5CMLISOSLWL 20 7/0.67 0.6 2.5 54.4 6278

Product Code No. of Triples

Strand No. / Diameter

(mm)

Insulation Thickness

(mm)

Armour Wire Diameter (mm)

Overall Cable Diameter (mm)

Approx. Weight of Completed Cable

(kg/km)

Conductor 1.5 mm2

02t01.5CMLISOSLWL 2 7/0.53 0.6 1.6 25.1 1301

04t01.5CMLISOSLWL 4 7/0.53 0.6 1.6 26.5 1715

06t01.5CMLISOSLWL 6 7/0.53 0.6 1.6 31.6 2234

10t01.5CMLISOSLWL 10 7/0.53 0.6 2.0 40.7 3448

12t01.5CMLISOSLWL 12 7/0.53 0.6 2.0 41.9 3776

15t01.5CMLISOSLWL 15 7/0.53 0.6 2.5 47.7 4926

Conductor 2.5 mm2

02t02.5CMLISOSLWL 2 7/0.67 0.6 1.6 27.2 1511

04t02.5CMLISOSLWL 4 7/0.67 0.6 1.6 28.7 2028

06t02.5CMLISOSLWL 6 7/0.67 0.6 2.0 35.1 2610

10t02.5CMLISOSLWL 10 7/0.67 0.6 2.5 45.4 4219

12t02.5CMLISOSLWL 12 7/0.67 0.6 2.5 47.1 4568

15t02.5CMLISOSLWL 15 7/0.67 0.6 2.5 52.0 5343

Page 123: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

BICC CABLES

7.0 GLOSSARY

Page 124: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities
Page 125: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

124 BICC CABLES

AAbrasion ResistanceAbility of a material or cable to resist surface wear.A.C. ResistanceThe total resistance offered by a device to alternating current circuit due to inductive and capacitive effects,as well as the direct current resistance.Active currentIn an alternating current, a component in phase with the voltage. The working component as distinguished from the idle or wattles component.Aerial cableA cable suspended in the air on poles or otheroverhead structure.Alternating current (AC)An electric current that continually reverses its direction giving a repetitive plus and minus wave form at fixed intervals.Alternating voltageThe voltage developed across a resistance or impedance through which alternating current is flowing.Ambient temperatureThe romal temperature within a given area.American wire gaugeA standard used in the determination of the physical size of a conductor determined by its circular mil area. Usually expressed as AWG. Also referred to as Brown and Sharpe (B&S) wire gauge.AmpacityThe maximum current an insulated wire or cable can safely carry without exceeding either the insulation or jacket material limitations (Same as current carrying capacity).AmpereThe current unit. One ampere is the current flowing through one ohm of resistance at one volt potential.Anneal To subjectto high heat wit subsequent cooling. When annealing copper, the act of softening the metal by means of heat to render it less brittle expressed in Hertz.Area of conductorThe size of conductor cross-section measured in circular mils, square inches, etc.ArmorA braid or wrapping of metal, usually steel, used for mechanical protection.Armored cableA cable having a metallic covering for protection against mechanical injury.ASTMThe American Society for Testing and MaterialsAWGAbbreviation for American Wire Gauge.

BBare conductorA conductor having no covering.A conductor with no coatingor cladding on the copper.BeddingA layer of material applied to a cable immediatelybelow the armoring.BinderA spirally served tape or thread used for holding assembled cable components in place awaiting subsequent manufacturing operations.BraidA fibrous or metallic group of filaments interwoven in cylindrical form to form a covering over one or more wires.Breakdown of insulationFailure of an insulated conductor resulting a flow of current through the insulation. It may be caused by the application of excess voltage or by defects or decay.Break down voltageThe voltage at which the insulation between two conductors breaks down.Bunched StrandAny number of conductor strands twisted together in one direction with the same lay length.Buried CableA cable installed directly in the ground without use of under ground conduit. Also called "direct burial cable".

CCableA group of individually insulated conductors in twisted or parallel configuration, with or without an overall covering.CablingThe act of twisting together two or more insulated components by machine to form a cable.CapacitanceStorage of electrically separated charges between two plates having different potentials.The value depends on the surface area of the plates and the distance and material between them.The quantity of electricity held statically in a capacitor or an insulated conductor.Colour CodeA colour system for circuit identification by use of solid colours, tracers, braids, surface printing, etc.Composite cableA cable consisting of two or more different types or sizes of wires.

7.0 Glossary

Page 126: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

125

ConcentricityIn a wire or cable, the measurement of the location of the center of the conductor with respect to the geometric center of the circular insulation.Concentric StrandingA group of wires twisted so as to contain a center core with one or more distinct layers of spirally wrapped, wires laid overall.ConductanceThe ability of a conductor to carry electric current.It is the reciprocal of resistance and is measured in Mhos.ConductivityA term used in describing the capability of a material to carry an electrical charge. Usually expressed as a percentage of copper conductivity.ConductorAny material capable of transferring electrical charge easily.CoreIn cables, a term used to denote a component or assembly of components, over which other materials are applied, such as additional components, shield, sheath, or armor.Cross-Sectional AreaThe area of the cut surface of an object cut at right angles to the length of the object.CurrentThe rate of flow of electricity in a circuit, measured in amperes.Current Carrying Capacity The maximum current an insulated conductor or cable can continuously carry without exceeding its temperature rating.It is also called ampacity.Direct Current (DC)Electrical current whose electrons flow in one direction only;it may be constant or pulsating as long as their movementis in the same direction.CycleThe complete sequence of alternation or reversal of alternation or reversal of the flow of an alternating electric current.(See Hertz)

Dielectric testA test in which a higher than the rated voltage is applied for a specified time to determine the adequacy of the insulation under normal conditions.Direct capacitanceThe capacitance measured directly from conductor to conductor through a single insulation layer.Direction of LayThe direction, either clockwise or counterclockwise,of a conductor or group of conductors when looking axiallydown a cable length.Drawingin The manufacturing of wire , pulling the metal through a die or series dies for reduction of diameter to a specified size.

DDCAbbreviation for "Direct Current".Dielectric Constant (K)The ratio of the capacitance of a capacitor (or consoles) with dielectric between the electrodes to the capacitance with air is between the electrodes. Also called permittivity and specific inductive capacity.Dielectric StrengthThe voltage which an insulation can withstand before breakdown occurs. Usually expressed as a voltage gradient(such as volts per mil).

EEccentricityLike concentricity, a measure of the center of a conductor's location with respect to the circular cross-section of the insulation; expressed as a percentage of center displacement of one circle within the other.EmbossingA means of identification or lettering using heat and or pressure to leave raised lettering on the sheath material of the cable.ExtrusionThe process of continuously forcing a plastic or elastomer and a conductor core through a die, thereby applying a continuous coating of insulation or jacket to the core or conductor.

FFaradA unit of electrical capacity.Filler(1) A material used in the cable to fill large interstices between

electrical components;(2) A substance, often inert, added to a compound to improve

properties and / or decrease cost.Flame ResistanceAbility of the material to extinguish flame once the source of heat is removed.Flexible CableA cable containing one or more cores, each formed of a group of wires, the diameters of the wires being sufficiently small to afford flexibility.FlexibilityThe ease with which a cable may be bent.FrequencyNumber of times an alternating current reverses itself in one second. Expressed in Hertz (Hz), which is one cycle per second.

Page 127: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

126 BICC CABLES

JJacketA material covering over a wire insulation or an assembly of components. An overall jacket on a complex cable grouping is also often referred to as a sheath

KKilohertz1000 Hertz (cycles per second}.KilovoltA term denoting 1000 volts.KilowattA term denoting 1000 watts.

HHarnessAn arrangement of wires and cables, usually with many breakouts, which have been tied together or pulled into a rubber or plastic sheath, used to interconnect electric circuit.Heat ResistanceAbility of a substance to maintain physical chemical and electrical integrity under specified temperature conditions.HenryUnit of inductance such that the induced voltage in volts is numerically equal to the rate of change of current inamperes per second.Hertz (Hz)A term replacing cycles-per seconds as a unit of frequency.High Temperature wire and cableThose electrical wires and cables having thermal operating characteristics of 125°C and higher.HzAbbreviation for Hertz.

IICEAAn Insulated Cable Engineers Association (formerly IPCEA) IECInternational Electro technical Commission, Similar to the ISO in structure and scope.IEEEInstitute of Electrical and Electronic Engineers.impedanceThe total opposition that a circuit offers to the flow of alternating current or any other varying current at a particular frequency. It is a combination of resistance R and reactance X,measured in ohms.impulse (Or pulse}A surge of unidirectional polarity.induced CurrentAn electric current set up in a circuit by interacting electrical fields. A Current caused by electromagnetic induction.inductanceThe property of a circuit element that opposes a change in current flow, thus causing current change to lag behind voltage changes. It is measured in Henrys.inductionThe phenomenon of a voltage, magnetic field or electrostatic charge being produced in an object by lines of force from the source of such fields.

GGaugeA term used to denote physical size.

LLay DirectionThe direction in which the strands of a conductor run over the top of the conductor as they recede from and observer looking along the axis of the conductor.Leakage CurrentThe undesirable flow of current through or over the surface of insulation.

MMega ohmOne million ohms.MhoThe unit of conductivity. The reciprocal of an ohm.

Inductive couplingCrosstalk resulting from the action of the electromagnetic field of one conductor on the other.insulationA non-conductive material usually surrounding or separating two conductive materials. Often called the dielectric in a radio frequency cable.insulation ResistanceThat property of an insulating material which resists electrical current flow through the insulating material when a potential difference is applied.Insulation ThicknessThe wall thickness of the applied insulation.InterferenceAny undesired electrical signal induced into a conductor by electrical or electromagnetic means (Noise).ISOInternational Standards Organization.

7.0 Glossary

Page 128: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

127

OOhmUnit of resistance such that a constant current of one Ampere produces a force of one volt.Overall DiameterFinished diameter over wire or cable.Over CurrentThe Current which causes an excessive temperature risein a conductor.Overload Capacity The maximum level of current, voltage, or power which a device can withstand before it is damaged.

RRated TemperatureThe maximum temperature at which an electric component can operate for extended periods without loss of its operating properties.Rated VoltageThe maximum voltage at which an electric component can operate for extended periods without degradation of performance or safety hazard.ReactanceThe opposition offered to the flow of alternating current by the inductance or capacitance of a component or circuit.ResistanceIn D.C. circuits, the opposition a material offers to current, measured in ohms. In A.C. Circuits, resistance is the real component of impedance, and may be higher than the value measured at D.C.Round ConductorA conductor whose cross-section is substantially circular.

QQuadA four- wire unit of insulated conductors.

PPolyesterPolyethylene terephthalate which is used extensively in the production of a high strength moisture resistant film used as cable core wrapping material.PolyethyleneA family of insulating materials derived from polymerization of ethylene gas. They are basically pure hydrocarbon resins, with excellent dielectric properties.Polyvinly chloride (PVC).A thermoplastic material composed of polymers of vinyl chloride which may be rigid or elastomeric, depending on specific formulation.Power FactorThe ratio of resistance to impedance. The ratio of the actual power of an alternating current to apparent power. Mathematically, the cosine of the angle between the voltage applied and the current resulting.Propagation timeTime required for an electrical wave to travel between two points on a transmission line.

MhzMegahertz (one million cycles per second).Moisture ResistanceThe ability of a material to resist absorbing moisture from the air or when immersed in water.Multi-ConductorMore than one conductor within a single cable.Mutual inductanceThe ratio of voltage induced in one conductor to the time rate of current change in the separate conductor causing this induction.MylarDuPont trademark for polyethylene terephthalate (polyester) film used in the form of a tape.

PulseA current or voltage which changes abruptly from one value to another and back to the original value in a finite length of time.Pulse CableA type of coaxial cable constructed to transmit repeated high voltage pulses without degradation.

SSheathThe material, usually an extruded plastic or elastomer, applied outer most to a wire or cable. Very often referred to as a jacket.ShieldA metallic layer around an insulated conductor or group of conductors to prevent electrostatic or electromagnetic interference between the enclosed wires and external fields. This shield can be braided or served wires, foil wrap, foil backed tape, a metallic tube, or conductors. the

shielding effectiveness is in proportion to the amount of coverage,

usually expressed in percentage.

Shield CoverageThe physical area of a cable that is actually covered by the shielding material and is expressed in percentage.SignalCurrent used to convey information, either digital, analogue, audio or video.

Page 129: BICC CABLES · BICC Cables Scope of production includes as follows: 1.0 BICC Cables Background. 7 1.3 Product Quality Quality Control in all steps of manufacturing is one of the priorities

128 BICC CABLES

VVelocity of PropagationThe speed of an electric signal down a length of cable compared to speed in free space expressed as a percentage. It is the reciprocal of the square root of the dielectric constant of the cable insulation.

TTemperature RatingThe maximum temperature at which insulating material may be used in continuous operation without loss of its basic properties.Tensile strengthA term denoting the greatest longitudinal tensile stressa substance can bear without mechanical failure.Thermal RatingThe maximum and / or minimum temperature at which a material will perform its functions without undue degration .Thermal ShockA test to determine the ability of a material to withstand heat and cold by subjecting it to rapid and wide change in temperature.Tinned CopperTin coating over copper to aid in soldering and inhibit corrosion.Tinned wireCopper wire that has been coated with a layer of tin or solder to simplify soldering.

WWattA unit of electrical power. One watt is equivalent to the power generated by one ampere of current under a pressure of one volt in a D.C. circuit.

Single cableA cable designed to carry current of usually less than one ampere per conductor.Solid ConductorA conductor consisting of a single wire.Spark TestA test designed to locate imperfections (usually pin- holes) in a wire insulation by application of an electrical potential across the material for a short period of time while the wire is drawn through an electrode field with one end of the wire grounded.Stranded conductorA conductor composed of individual groups of wires twisted together to form an entire unit.Strand Lay lengthA distance of advance of a strand of a spirally stranded conductor, in one turn, measured axially.

Volt (potential difference}A unit of electrical pressure. One volt is the amount of pressure that will cause one ampere of current in one ohm of resistance.VoltageThe term most often used in place of electromotive force, potential, potential difference, or voltage drop, to designate electric pressure that exists between two points and is capable of producing a flow of current when a circuit is connected between the two points.Voltage DropThe amount of voltage loss between two power in a circuit.Voltage RatingThe highest voltage that may be continuously applied to a wire or cord in conformance with standards or specifications.Volume ReceptivityThe electrical resistance between opposite face of a 1 cm cube of insulating material commonly expressed in ohms/ centimeter.

7.0 Glossary