6
Normal dimming load Violet Normal Dimming Load Gray Red White G V H N 4x4 JUNCTION BOX Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing FX FX SP SP B A CAT5/6 Cable NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing FX FX SP SP B A Blue (Test Loop) ALCR1277 Emergency Light Controller (Red) Emergency Pow Output On Black (Green) Normal Power Blue (Test Loop) Purple (Dimmer Loop) Purple (Dimmer Loop) White Red Red Gray Black C Cntrl. H N Normal Dimming Load 1 H N Normal/Emergency Dimming Load 1 To Optional Remote Test Switch + - + - Gray (-) (0-10VDC) Violet (+) (0-10VDC) Gray (-) Violet (+) Gray (-) Violet (+) Normal/Emergency Switched Normal/Emergency (Line 120/277 VAC) Normal/Emergency (Neutral) Normal/Emergency Power Neutral Line Line Neutral SVC PWR SVC PIN ON OFF NXRCFX - 1RD FX FX SP SP B A TEST SWITCH EMERGENCY POWER UTILITY POWER UL924EPC1D-UNV Emergency Light Load Controller 1 Black (120V) 2 Orange (277V) 4 White 3 Red 6 Yellow 7 White/Blue N Normal Dimming Load 1 Neutral Line N Normal/Emergency Dimming Load 1 Line Neutral Normal/Emergency (Line -120/277 VAC) Normal/Emergency Neutral Normal/Emergency Switched 5 Blue Select connection wire based on voltage Black Blue (+0-10V In) Red (+0-10V Out) Cap off Plenum Low Voltage Wiring + - - + Gray (-) Violet (+) Gray (-) Violet (+) Gray (-) (0-10VDC) Violet (+) (0-10VDC) S1. C5 NX Switch Station Typical Model : NXSW-ORLO 18 AWG CAT5/6 Cable SVC PIN SVC PWR NX Switch Station Typical Model : NXSW-6 NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing S1. C1 Normal / Emergency dimming load with ALCR1277 Normal / Emergency dimming load with UL924EPCID-UNV 18 AWG 18 AWG Line 120/270 VAC Line 120V/277 VAC NXRCFX - 1RD 4x4 JUNCTION BOX 4x4 JUNCTION BOX NXRCFX - 1RD Normal / Emergency dimming load with UL1008BCELTS1277 NXRCFX - 1RD FX FX SP SP B A H N Normal/Emergency Dimming Load 1 #3 Blue #12 Blue #1 Orange UTILITY EMERGENCY STATUS TEST SET #4 White/Blue #13 White/Blue UL1008BCELTS1277 16Amps Max. Normal/Emergency (Line 120/277VAC) Normal/Emergency Neutral H N Normal Dimming Load 1 #6 Red/White #5 Red + - + - #9 Yellow Cap Off Red Loop (20AWG) for use with a Normally Closed Maintained Fire Alarm Switch #11 White #2 White #10 Black #7 Purple (Out) #8 Brown (In) Normal/Emergency Switched Neutral Normal Switched Gray (-) (0-10VDC) Violet (+) (0-10VDC) 4x4 JUNCTION BOX Line 120/277 VAC Neutral Normal Switched Neutral Normal Switched 18 AWG 18 AWG Normal/Emergency Power 18 AWG 18 AWG G V H N FX FX SP SP B A Normal Dimming Load 18 AWG Red White NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Violet Gray NXRCFX - 1RD 4x4 JUNCTION BOX 4x4 JUNCTION BOX Line Voltage Receptacles NXRC-1R B A CAT5/6 Cable Normal dimming load and receptacle load SVC PWR SVC PIN ON OFF SVC PIN SVC PWR CAT5/6 Cable NX Switch Station Typical Model : NXSW-ORLO NX Switch Station Typical Model : NXSW-6 FX FX SP SP B A NXRCFX - 1RD 4x4 JUNCTION BOX Reverse phase Load PHDIM-1277 Violet Gray Purple Gray White N Red Gray Black H Red JUNCTION BOX (OPTIONAL) JUNCTION BOX Switched Hot 18 AWG Reverse phase load Networked normal / emergency dimming load on NX UL924 room controller NXRCFX-1RD B A 4x4 JUNCTION BOX Neutral Red White Neutral Switched Hot Violet Normal Dimming Load Gray Red White G V H N 4x4 JUNCTION BOX FX FX SP SP B A 18-22 AWG NXRCFX - 1RD SVC PWR SVC PIN ON OFF SVC PIN SVC PWR CAT5/6 Cable NX Switch Station Typical Model : NXSW-ORLO NX Switch Station Typical Model : NXSW-6 NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing CAT5/6 Cable Networked normal / emergency dimming load on NX UL924 room controller and receptacle load Violet Normal Dimming Load Gray Red White G V H N 4x4 JUNCTION BOX FX FX SP SP B A 18 AWG NXRCFX - 1RD NXRM-H Networked normal dimming load S1. C6 S1. C7 S1. C8 S1. C9 S1. C11 S1. C2 Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI 12 AWG Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI H H 12 AWG 12 AWG 12 AWG SVC PWR SVC PIN ON OFF NX Switch Station Typical Model : NXSW-ORLO CAT5/6 Cable SVC PIN SVC PWR NX Switch Station Typical Model : NXSW-6 NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI 12 AWG 18 AWG 18 AWG Normal/Emergency Power SVC PWR SVC PIN ON OFF NX Switch Station Typical Model : NXSW-ORLO CAT5/6 Cable SVC PIN SVC PWR NX Switch Station Typical Model : NXSW-6 NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI 12 AWG Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI Black (Line 120/277 VAC) White (Neutral) Normal Power 12 AWG Ground Black (Line 120/277/347 VAC) White (Neutral) Normal Power 12 AWG Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing CAT5/6 Cable SVC PWR SVC PIN ON OFF NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing NX Switch Station Typical Model : NXSW-ORLO Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI Line Voltage Receptacles Red White Neutral Switched Hot 12 AWG Ground Black (Line 120/277 VAC) White (Neutral) 12 AWG Black (Line 120/277 VAC) White (Neutral) Normal Power Black (Line 120/277 VAC) White (Neutral) Normal Power Black (Line 120/277/347 VAC) White (Neutral) Normal Power Black (Line 120 VAC) White (Neutral) Normal Power 12 AWG Black (Line 120 VAC) White (Neutral) Normal Power 12 AWG Black (Line 120/277/347 VAC) White (Neutral) Normal Power 12 AWG NX Bridge Module NXHNB2 N H1 V1 G Violet Gray Red White White (Neutral) 18 AWG CAT5/6 Cable 4x4 JUNCTION BOX B A Blue Blue Remote Test Button or Fire Alarm interface NXRC-UL924-UNV Normal / Emergency Power White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG NX Bridge Module NXHNB2 N H1 V1 G Violet Gray Red White White (Neutral) 18 AWG CAT5/6 Cable 4x4 JUNCTION BOX B A Blue Blue Remote Test Button or Fire Alarm interface NXRC-UL924-UNV Normal / Emergency Power White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG Violet Normal Dimming Load Gray Red White G V H N 4x4 JUNCTION BOX FX FX SP SP B A 18 AWG NXRCFX - 1RD 12 AWG NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing SVC PWR SVC PIN ON OFF SVC PIN SVC PWR CAT5/6 Cable NX Switch Station Typical Model : NXSW-ORLO NX Switch Station Typical Model : NXSW-6 Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI 12 AWG Black (Line 120/277/347 VAC) White (Neutral) Normal Power Black (Line 120/277/347 VAC) White (Neutral) Normal Power Black White Red Red Gray Black 16 AWG 12 AWG 12 AWG 16 AWG 16 AWG 16 AWG 18 AWG 12 AWG 18 AWG 12 AWG 12 AWG 12 AWG UL1008BCELTS1277 The Gauge number near to lead numbers and lead color of this device are the gauge size of wires coming out of the device. Please refer to specification and install cut sheets. ALCR1277 The Gauge number near to lead color of this device are the gauge size of wires coming out of the device. Please refer to specification and install cut sheets. Violet Gray Violet Gray Violet Gray 18 AWG 16 AWG 16 AWG 12 AWG 12 AWG 18 AWG 18 AWG 12 AWG SVC PWR SVC PIN ON OFF NX Switch Station Typical Model : NXSW-ORLO SVC PIN SVC PWR NX Switch Station Typical Model : NXSW-6 NX SMART PORT NX SMART PORT J1 J2 Pilot Input 2 Input 1 +24V 1: 2: 3: 4: 1 2 3 4 NXCI Violet Normal Dimming Load Gray Red White G V H N 4x4 JUNCTION BOX Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing FX FX SP SP B A CAT5/6 Cable NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing 18 AWG NXRCFX - 1RD Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI 12 AWG Black (Line 120/277/347 VAC) White (Neutral) Normal Power SVC PWR SVC PIN ON OFF NX Switch Station Typical Model : NXSW-ORLO SVC PIN SVC PWR NX Switch Station Typical Model : NXSW-6 To Additional NX room devices Violet Normal Dimming Load Gray Red White G V H N 4x4 JUNCTION BOX FX FX SP SP B A CAT5/6 Cable NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing 18 AWG NXRCFX - 1RD 12 AWG Black (Line 120/277/347 VAC) White (Neutral) Normal Power SVC PWR SVC PIN ON OFF NX Switch Station Typical Model : NXSW-ORLO SVC PIN SVC PWR NX Switch Station Typical Model : NXSW-6 Normal dimming load with key switch S1. C3 Normal dimming load with integration to BMS systems S1. C4 Normal Power S1. C10 Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing CAT5/6 Cable NX Wall Station. (NXSW) The NXSW wall station shown is for representation purposes. Additional switches can be daisy chained using similar wiring up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing SVC PWR SVC PIN ON OFF NX Switch Station Typical Model : NXSW-ORLO SVC PIN SVC PWR NX Switch Station Typical Model : NXSW-6 Normal Switched Normal Neutral Normal Switched Normal Neutral Normal Switched Normal Neutral Normal/Emergency Neutral 12 AWG 12 AWG 12 AWG 18 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 AWG LVSKEY-3M-SS Black/White Black Blue (CCW) Blue /White (CW) Normally Open Common Normally Closed 1 AMP 24 VOLTS AC OR DC NXRO Dry Contact Output HVAC Panel or any other BMS Systems Example of a BMS System NX SMART PORT NX SMART PORT J1 J2 Common 18 AWG 18 AWG CAT5/6 Cable Neutral Line Line Neutral (As required) (As required) (As required) (As required) (As required) (As required) (As required) (As required) (As required) SVC PIN SVC PWR NX Switch Station Typical Model : NXSW-6 (As required) (As required) (As required) Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) CAT5/6 Cable Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI (As required) Ground Ground CAT5/6 Cable Low Voltage Occupancy Sensor Select model of sensor based on application and requirement. Additional sensors can be added in the daisy chain up to 'X' nos. observing power budget of controller. Please refer to notes section in this drawing Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI Low Voltage Occupancy Sensor Typical Model : NXSMP-OMNI CAT5/6 Cable NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 CAT5/6 Cable CAT5/6 Cable NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 CAT5/6 Cable CAT5/6 Cable NXCBL + CAT5/6 Cable Refer to Detail-1 in drawing no. HCS - NX - S4 HubbNET Network HubbNET Network HubbNET Network HubbNET Network Notes 1. For Power budget of Room controllers and device loads, Please refer "3451B_NX_Room_Controller_Install_and_Operation.pdf". See document link:https://hubbellcdn.com/installationmanuals/3451B_NX_Room_Controller_Install_and_Operation.pdf. (See Note 10 below) 2. For NX Smart switches (NXSW-1 upto NXSW-6 switch stations), each buttons on the station maybe programmed for different functions as desired using NX Device Setup App. Please refer 3457.1A_NX_Smart_Switch.pdf See document link: https://hubbellcdn.com/specsheet/3457.1A_NX_Smart_Switch.pdf 3. For NX Speciality switches (NXSW-OO/ ORLO / RL switch stations), please refer 3457.2A_NX_Specialty_Switches.pdf See document link: https://hubbellcdn.com/specsheet/3457.2A_NX_Specialty_Switches.pdf 4. For guide on NX Switch stations, please refer HCS_NX_Switch_Guide.pdf. See document link: https://hubbellcdn.com/literature/HCS_NX_Switch_Guide.pdf 5. For NX Occupancy sensors, please refer 3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf and 3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf. See document link: https://hubbellcdn.com/specsheet/3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf See document link:: https://hubbellcdn.com/specsheet/3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf 6. For Occupacy sensors selection guide, please refer : Sensor_Selection_Tool.pdf and for application guide, refer : HCS_Sensor_B.pdf See document link: https://hubbellcdn.com/literature/Sensor_Selection_Tool.pdf See document link: https://hubbellcdn.com/brochure/HCS_Sensor_B.pdf 7. For NXSMP-OMNI Indoor/Outdoor sensors, Please refer document OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf See link: https://hubbellcdn.com/specsheet/NX_OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf 8. For NX Brochure, Please see link: https://hubbellcdn.com/brochure/HCS_NX_Brochure.pdf 9. For NX Design Application guide, Please see link: https://hubbellcdn.com/brochure/NX_Design_Application_Guide.pdf 10. MAXIMUM POWER BUDGET PER ROOM CONTROLLER OR IN-FIXTURE MODULE = +30 PBUs. ----Blank---- ----Blank---- Gray Violet FX FX SP SP DRAWN BY: DATE: DRAWING / DESIGN NO.: SCALE: REV. TITLE: 07/06/2020 SR 0 NTS 701 Millennium Blvd. Greenville, SC 29607 www.hubbellcontrolsolutions.com NX TYPICAL CONFIGURATIONS: NXFX CONTROLLERS WITH SINGLE LOAD HCS - NX - S1 Main Switchboard: (864) 678-1000 Technical Service: (800) 888-8006 Date By Rev. 05/20/21 AJ B

Blank---- Typical... · 2020. 8. 31. · White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG Violet Normal Dimming Load

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Blank---- Typical... · 2020. 8. 31. · White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG Violet Normal Dimming Load

Normal dimming load

Violet

Normal Dimming

Load

Gray

Red

White

G

V

H

N

4x4 JUNCTION

BOX

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

FX FX SP SP

BA

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

FX FX SP SP

BA

Blue (Test Loop)

ALCR1277

Emergency Light Controller

(Red)

Emergency Pow

Output On

Black

(Green)

Normal Power

Blue (Test Loop)

Purple (Dimmer Loop)

Purple (Dimmer Loop)

White

Red

Red

Gray

Black

C

Cntrl.

H

NNormal Dimming

Load 1

H

N

Normal/Emergency

Dimming Load 1

To Optional Remote

Test Switch

+

-

+

-

Gray (-) (0-10VDC)

Violet (+) (0-10VDC)

Gray (-)

Violet (+)

Gray (-)

Violet (+)

Norm

al/E

mergency S

witched

Normal/Emergency (Line 120/277 VAC)

Normal/Emergency (Neutral)

Normal/Emergency Power

Neutral

Line

Line

Neutral

SV

C

PW

RS

VC

P

IN

ON

OFF

NXRCFX - 1RD

FX FX SP SP

BA

TEST SWITCH

EMERGENCY

POWER

UTILITY

POWER

UL924EPC1D-UNVEmergency LightLoad Controller

1 Black (120V)

2 Orange (277V)

4 White

3 Red

6 Yellow

7 White/Blue

N

Normal Dimming

Load 1

Neutral

Line

N

Normal/Emergency

Dimming Load 1

Line

Neutral

Normal/Emergency (Line -120/277 VAC)

Normal/Emergency Neutral

Norm

al/E

mergency S

witched

5 Blue

Select

connection

wire

based on

voltage

Black

Blue

(+0-10V In)

Red

(+0-10V Out)

Cap off

Plenum

Low

Voltage

Wiring

+

-

-

+

Gray (-)

Violet (+)

Gray (-)

Violet (+)

Gray (-) (0-10VDC)

Violet (+) (0-10VDC)

S1. C5

NX Switch Station

Typical Model :

NXSW-ORLO

18 AWG

CAT5/6 Cable

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

S1. C1

Normal / Emergency dimming load with ALCR1277 Normal / Emergency dimming load with UL924EPCID-UNV

18 AWG

18 AWG

Line 120/270 VAC

Line 120V/277 VAC

NXRCFX - 1RD

4x4 JUNCTION

BOX

4x4 JUNCTION

BOX

NXRCFX - 1RD

Normal / Emergency dimming load with UL1008BCELTS1277

NXRCFX - 1RD

FX FX SP SP

BA

H

N

Normal/Emergency

Dimming Load 1

#3

B

lu

e

#1

2 B

lu

e

#1 Orange

UTILITY

EMERGENCY

STATUS

TEST

SET

#4

W

hite

/B

lu

e

#1

3 W

hite

/B

lu

e

UL1008BCELTS1277

16Amps Max.

Normal/Emergency (Line 120/277VAC)

Normal/Emergency Neutral

H

N

Normal Dimming

Load 1

#6 Red/White

#5 Red

+

-

+

-

#9 Yellow

Cap Off

Red Loop (20AWG) for use with a

Normally Closed Maintained

Fire Alarm Switch

#11 White

#2 White

#10 Black

#7 Purple (Out)

#8 Brown (In)

No

rm

al/E

me

rg

en

cy S

witch

ed

Neutral

Normal Switched

Gray (-) (0-10VDC)

Violet (+) (0-10VDC)

4x4 JUNCTION

BOX

Line 120/277 VAC

Neutral

Normal Switched

Neutral

Normal Switched

18 AWG

18 AWG

Normal/Emergency Power

18 AWG

18 AWG

G

V

H

N

FX FX SP SP

BA

Normal Dimming

Load

18 AWG

Red

White

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Violet

Gray

NXRCFX - 1RD

4x4 JUNCTION

BOX

4x4 JUNCTION

BOX

Line Voltage

Receptacles

NXRC-1R

BA

CAT5/6 Cable

Normal dimming load and receptacle load

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

FX FX SP SP

BA

NXRCFX - 1RD

4x4 JUNCTION

BOX

Reverse phase

Load

PHDIM-1277

Violet

Gray

Purple

Gray

White

N

Red

Gray

Black

H

Red

JUNCTION

BOX

(OPTIONAL)

JUNCTION

BOX

Switched Hot

18 AWG

Reverse phase load

Networked normal / emergency dimming load on NX UL924 room controller

NXRCFX-1RD

BA

4x4 JUNCTION

BOX

Neutral

Red

White

Neutral

Switched Hot

Violet

Normal Dimming

Load

Gray

Red

White

G

V

H

N

4x4 JUNCTION

BOX

FX FX SP SP

BA

18-22 AWG

NXRCFX - 1RD

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

Networked normal / emergency dimming load on NX UL924 room controller and receptacle load

Violet

Normal Dimming

Load

Gray

Red

White

G

V

H

N

4x4 JUNCTION

BOX

FX FX SP SP

BA

18 AWG

NXRCFX - 1RD

NXRM-H

Networked normal dimming load

S1. C6 S1. C7

S1. C8 S1. C9

S1. C11

S1. C2

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

12 AWG

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

H

H

12 AWG

12 AWG

12 AWG

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

CAT5/6 Cable

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

12 AWG

18 AWG

18 AWG

Normal/Emergency

Power

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

CAT5/6 Cable

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

12 AWG

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

12 AWG

Ground

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

12 AWG

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

NX Switch Station

Typical Model :

NXSW-ORLO

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Line Voltage

Receptacles

Red

White

Neutral

Switched Hot

12 AWG

Ground

Black (Line 120/277 V

AC

)

White (N

eutral)

12 AWG

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

12 AWG

NX Bridge Module

NXHNB2

N

H1

V1

G

Violet

Gray

Red

White

White (N

eutral)

18 AWG

CAT5/6 Cable

4x4 JUNCTION

BOX

BA

Blu

e

Blu

e

Remote Test Button or

Fire Alarm interface

NXRC-UL924-UNV

Normal / Emergency Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

Cap Off

12 AWG

Normal/Emergency

Dimming Load

12 AWG

NX Bridge Module

NXHNB2

N

H1

V1

G

Violet

Gray

Red

White

White (N

eutral)

18 AWG

CAT5/6 Cable

4x4 JUNCTION

BOX

BA

Blu

e

Blu

e

Remote Test Button or

Fire Alarm interface

NXRC-UL924-UNV

Normal / Emergency Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

Cap Off

12 AWG

Normal/Emergency

Dimming Load

12 AWG

Violet

Normal Dimming

Load

Gray

Red

White

G

V

H

N

4x4 JUNCTION

BOX

FX FX SP SP

BA

18 AWG

NXRCFX - 1RD

12 AWG

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

12 AWG

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

Black

White

Red

Red

Gray

Black

16 AWG

12 AWG

12 AWG

16 AWG

16 AWG

16 AWG

18 AWG

12 AWG

18 AWG

12 AWG

12 AWG

12 AWG

UL1008BCELTS1277

The Gauge number near to lead numbers and

lead color of this device are the gauge size of

wires coming out of the device. Please refer to

specification and install cut sheets.

ALCR1277

The Gauge number near to lead color of this

device are the gauge size of wires coming out

of the device. Please refer to specification and

install cut sheets.

Violet

Gray

Violet

Gray

Violet

Gray

18 AWG

16 AWG

16 AWG

12 A

WG

12 A

WG

18 A

WG

18 A

WG

12 AWG

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

NX SMART PORT

NX SMART PORT

J1

J2

Pilot

Input 2

Input 1

+24V1:

2:

3:

4:

1234

NXCI

Violet

Normal Dimming

Load

Gray

Red

White

G

V

H

N

4x4 JUNCTION

BOX

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

FX FX SP SP

BA

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

18 AWG

NXRCFX - 1RD

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

12 AWG

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

To Additional NX room devices

Violet

Normal Dimming

Load

Gray

Red

White

G

V

H

N

4x4 JUNCTION

BOX

FX FX SP SP

BA

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

18 AWG

NXRCFX - 1RD

12 AWG

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

Normal dimming load with key switchS1. C3

Normal dimming load with integration to BMS systemsS1. C4

Normal Power

S1. C10

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

Normal Switched

Normal Neutral

Normal Switched

Normal Neutral

Normal Switched

Normal Neutral

No

rm

al/E

me

rg

en

cy N

eu

tra

l

12 AWG

12 AWG

12 AWG

18 AWG

12 AWG

12 AWG

12 AWG

12 AWG 12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

LVSKEY-3M-SS

Black/White

Black

Blue (CCW)

Blue /White (CW) No

rm

ally O

pen

Co

mm

on

No

rm

ally C

lo

sed

1 AMP 24 VOLTS

AC OR DC

NXRO

Dry Contact

Output HVAC Panel

or any other BMS

Systems

Example of a BMS System

NX SMART PORT

NX SMART PORT

J1

J2

Co

mm

on

18 AWG

18 AWG

CAT5/6 Cable

Neutral

Line

Line

Neutral

(As required)

(As required)

(As required) (As required)

(As required)

(As required)

(As required)

(As required)

(As required)

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

(As required)

(As required)

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

CAT5/6 Cable

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Ground

Ground

CAT5/6 Cable

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

CAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

CAT5/6 CableCAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

CAT5/6 CableCAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

HubbNET NetworkHubbNET Network

HubbNET NetworkHubbNET Network

Notes

1. For Power budget of Room controllers and device loads, Please refer "3451B_NX_Room_Controller_Install_and_Operation.pdf".

See document link:https://hubbellcdn.com/installationmanuals/3451B_NX_Room_Controller_Install_and_Operation.pdf. (See Note 10 below)

2. For NX Smart switches (NXSW-1 upto NXSW-6 switch stations), each buttons on the station maybe programmed for different functions as desired

using NX Device Setup App. Please refer 3457.1A_NX_Smart_Switch.pdf

See document link: https://hubbellcdn.com/specsheet/3457.1A_NX_Smart_Switch.pdf

3. For NX Speciality switches (NXSW-OO/ ORLO / RL switch stations), please refer 3457.2A_NX_Specialty_Switches.pdf

See document link: https://hubbellcdn.com/specsheet/3457.2A_NX_Specialty_Switches.pdf

4. For guide on NX Switch stations, please refer HCS_NX_Switch_Guide.pdf.

See document link: https://hubbellcdn.com/literature/HCS_NX_Switch_Guide.pdf

5. For NX Occupancy sensors, please refer 3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf and

3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf.

See document link: https://hubbellcdn.com/specsheet/3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf

See document link:: https://hubbellcdn.com/specsheet/3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf

6. For Occupacy sensors selection guide, please refer : Sensor_Selection_Tool.pdf and for application guide, refer : HCS_Sensor_B.pdf

See document link: https://hubbellcdn.com/literature/Sensor_Selection_Tool.pdf

See document link: https://hubbellcdn.com/brochure/HCS_Sensor_B.pdf

7. For NXSMP-OMNI Indoor/Outdoor sensors, Please refer document OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

See link: https://hubbellcdn.com/specsheet/NX_OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

8. For NX Brochure, Please see link: https://hubbellcdn.com/brochure/HCS_NX_Brochure.pdf

9. For NX Design Application guide, Please see link: https://hubbellcdn.com/brochure/NX_Design_Application_Guide.pdf

10. MAXIMUM POWER BUDGET PER ROOM CONTROLLER OR IN-FIXTURE MODULE = +30 PBUs.

----Blank----

----Blank----

Gray

Violet

FX FX SP SP

DRAWN BY: DATE:

DRAWING / DESIGN NO.:

SCALE:REV.

TITLE:

07/06/2020SR

0NTS

701 Millennium Blvd.

Greenville, SC 29607

www.hubbellcontrolsolutions.com

NX TYPICAL CONFIGURATIONS:

NXFX CONTROLLERS WITH SINGLE LOAD

HCS - NX - S1

Main Switchboard: (864) 678-1000

Technical Service: (800) 888-8006

Date

By

Rev.

05/20/21 AJB

AutoCAD SHX Text
30-01249A
AutoCAD SHX Text
30-01249A
Page 2: Blank---- Typical... · 2020. 8. 31. · White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG Violet Normal Dimming Load

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

12 AWG

SV

C

PW

RS

VC

P

IN

ON

OFF

CAT5/6 Cable

SV

C P

IN

SV

C

PW

R

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

H1

NNormal Dimming

Load 1

N

Normal/Emergency

Dimming Load 1

+

-

+

-

Gray (-) (0-10VDC)

Violet/Striped (+) (0-10VDC)

Gray (-)

Violet (+)

Gray (-)

Violet (+)

Norm

al/E

mergency S

witched

Normal/Emergency (Line 120/277 VAC)

Normal/Emergency (Neutral)

Normal/Emergency Power

Line

Neutral

Normal Switched (Red)

18 AWG

18 AWG

Line 120/270 VAC

Neutral

Normal Switched (Red)

18 AWG

12 AWG

12 AWG

N

Normal Dimming

Load 2

+

-

Gray (-)

Violet/Striped(+)

Line

Neutral

Normal Switched (Blue)

18 AWG

12 AWG

Violet (+) (0-10VDC)

H

Neutral

Line

H2

Violet

Violet/S

triped

Gray

TEST SWITCH

EMERGENCY

POWER

UTILITY

POWER

UL924EPC1D-UNVEmergency LightLoad Controller

1 Black (120V)

2 Orange (277V)

4 White

3 Red

6 Yellow

7 White/Blue

5 Blue

Select

connection

wire

based on

voltage

Black

Blue

(+0-10V In)

Red

(+0-10V Out)

Cap off

Plenum

Low

Voltage

Wiring

S2. C8

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

12 AWG

SV

C

PW

RS

VC

P

IN

ON

OFF

CAT5/6 Cable

SV

C P

IN

SV

C

PW

R

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

H1

NNormal Dimming

Load 1

N

Normal/Emergency

Dimming Load 1

+

-

+

-

Gray (-) (0-10VDC)

Violet/Striped (+) (0-10VDC)

Gray (-)

Violet (+)

Gray (-)

Violet (+)

Norm

al/E

mergency S

witched

Line

Neutral

Normal Switched (Red)

18 AWG

18 AWG

Line 120/270 VAC

Neutral

Normal Switched (Red)

18 AWG

12 AWG

N

Normal Dimming

Load 2

+

-

Gray (-)

Violet/Striped(+)

Line

Neutral

Normal Switched (Blue)

18 AWG

12 AWG

Violet (+) (0-10VDC)

H

Neutral

Line

H2

Violet

Violet/S

triped

Gray

#3

B

lu

e

#1

2 B

lu

e

#1 Orange

UTILITY

EMERGENCY

STATUS

TEST

SET

#4

W

hite

/B

lu

e

#1

3 W

hite

/B

lu

e

UL1008BCELTS1277

16Amps Max.

Normal/Emergency (Line 120/277VAC)

Normal/Emergency Neutral

#6 Red/White

#5 Red

#9 Yellow

Cap Off

Red Loop (20AWG) for use with a

Normally Closed Maintained

Fire Alarm Switch

#11 White

#2 White

#10 Black

#7 Purple (Out)

#8 Brown (In)

12 AWG

Normal/Emergency

Power

18 AWG

12 AWG

18 AWG

12 AWG

12 AWG

12 AWG

18 AWG

16 AWG

16 AWG

12 A

WG

12 A

WG

18 A

WG

18 A

WG

12 AWG

UL1008BCELTS1277

The Gauge number near to lead numbers and

lead color of this device are the gauge size of

wires coming out of the device. Please refer to

specification and install cut sheets.

Norm

al/E

mergency N

eutral

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

CAT5/6 Cable

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

Reverse phase

Load 1

PHDIM-1277

White

N

Red

Gray

Black

Switched Hot (Red)

Neutral

12 AWG

Reverse phase

Load 2

PHDIM-1277

White

N

Blue

Gray

Black

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

12 AWG

Neutral

JUNCTION

BOX

(OPTIONAL)

JUNCTION

BOX

Gray

Gray

Purple

Gray

Gray

Violet/S

triped

Violet

Switched Hot (Blue)

White (N

eutral)

Purple

H2

12 AWG

H1

18 AWG

18 AWG

JUNCTION

BOX

(OPTIONAL)

S2. C6 Dual reverse phase load

Normal dimming loadS2. C1Networked normal dimming load

S2. C2

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Normal Power

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Black (Line 120/277/347 VAC)

White (Neutral)

-

N

Class 2 Driver with Max

Current of 2.5A

Red

White

H

+

+

-

+

-

CTC (Optional)

+

-

+

-

+

-

Driver

Output

0-10V

Input

0-10V

Input

Driver

Input

CH2 (+)

CH1 (+)

CH2 (+)

CH1 (+)

56VDC

Max Output

LED

Dimming Driver

(Constant Current)

For SpectraSync applications, the

highest CCT LED should be on CH1 and

the lower CCT LED should be on CH2.

Violet

Gray

Violet / Striped

Ca

p O

ff

Blue

12 AWG

18 AWG

Networked normal dimming load with CCT controlS2. C3

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

To Additional NX room Devices

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

Normal dimming load with key switchS2. C4

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

No

rm

ally O

pe

n

Co

mm

on

No

rm

ally C

lo

se

d

1 AMP 24 VOLTS

AC OR DC

NXRO

Dry Contact

Output HVAC Panel

or any other BMS

Systems

Example of a BMS System

Normal dimming load with integration to BMS systemsS2. C5

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

12 AWG

SV

C

PW

RS

VC

P

IN

ON

OFF

CAT5/6 Cable

SV

C P

IN

SV

C

PW

R

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Blue (Test Loop)

ALCR1277

Emergency Light Controller

(Red)

Emergency Pow

Output On

Black

(Green)

Normal Power

Blue (Test Loop)

Purple (Dimmer Loop)

Purple (Dimmer Loop)

White

Red

Red

Gray

Black

C

Cntrl.

H1

NNormal Dimming

Load 1

N

Normal/Emergency

Dimming Load 1

To Optional Remote

Test Switch

+

-

+

-

Gray (-) (0-10VDC)

Violet/Striped (+) (0-10VDC)

Gray (-)

Violet (+)

Gray (-)

Violet (+)

Norm

al/E

mergency S

witched

Normal/Emergency (Line 120/277 VAC)

Normal/Emergency (Neutral)

Normal/Emergency Power

Line

Neutral

Normal Switched (Red)

18 AWG

18 AWG

Line 120/270 VAC

Neutral

Normal Switched (Red)

18 AWG

12 AWG

N

Normal Dimming

Load 2

+

-

Gray (-)

Violet/Striped(+)

Line

Neutral

Normal Switched (Blue)

18 AWG

12 AWG

Violet (+) (0-10VDC)

H

Neutral

Line

H2

Violet

Violet/S

triped

Gray

16 AWG

12 AWG

12 AWG

16 AWG

16 AWG

16 AWG

ALCR1277

The Gauge number near to lead color of this

device are the gauge size of wires coming out

of the device. Please refer to specification and

install cut sheets.

Normal Neutral

Normal Neutral

Normal / Emergency dimming load with ALCR1277S2. C7 Normal / Emergency dimming load with UL924EPC1D-UNV

Normal Neutral

Normal Neutral

Normal Neutral

Normal Neutral

Normal / Emergency dimming load with UL1008BCELTS1277 Normal dimming and receptacle loadS2. C10S2. C9

Networked normal / emergency dimming load on NX UL924 room controllerS2. C11

Networked normal / emergency dimming load on NX UL924 room controller and receptacle load

S2. C12

4x4 JUNCTION

BOX

Line Voltage

Receptacles

NXRC-1R

BA

CAT5/6 Cable

Red

White

Neutral

Switched Hot

12 AWG

Ground

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG 12 AWG

12 AWG

12 AWG

NX SMART PORT

NX SMART PORT

J1

J2

Pilot

Input 2

Input 1

+24V1:

2:

3:

4:

1234

NXCI

Black/White

Black

Blue (CCW)

Blue /White (CW)

NX SMART PORT

NX SMART PORT

J1

J2

Co

mm

on

18 AWG

18 AWG

LVSKEY-SS

12 AWG

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

(As required)

(As required)

NXRM-H

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

(As required)

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

NX Switch Station

NXSW-CCT

SV

C

PW

RS

VC

P

IN

FOCUS

WORK

NORMAL

CALM

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

(As required)

NXRM-H

CAT5/6 Cable

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

(As required)

JUNCTION

BOX

(As required)

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

(As required)

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Ground

CAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

CAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

CAT5/6 Cable

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

CAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

Notes

1. For Power budget of Room controllers and device loads, Please refer "3451B_NX_Room_Controller_Install_and_Operation.pdf".

See document link:https://hubbellcdn.com/installationmanuals/3451B_NX_Room_Controller_Install_and_Operation.pdf. (See Note 10 below)

2. For NX Smart switches (NXSW-1 upto NXSW-6 switch stations), each buttons on the station maybe programmed for different functions as desired

using NX Device Setup App. Please refer 3457.1A_NX_Smart_Switch.pdf

See document link: https://hubbellcdn.com/specsheet/3457.1A_NX_Smart_Switch.pdf

3. For NX Speciality switches (NXSW-OO/ ORLO / RL switch stations), please refer 3457.2A_NX_Specialty_Switches.pdf

See document link: https://hubbellcdn.com/specsheet/3457.2A_NX_Specialty_Switches.pdf

4. For guide on NX Switch stations, please refer HCS_NX_Switch_Guide.pdf.

See document link: https://hubbellcdn.com/literature/HCS_NX_Switch_Guide.pdf

5. For NX Occupancy sensors, please refer 3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf and

3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf.

See document link: https://hubbellcdn.com/specsheet/3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf

See document link:: https://hubbellcdn.com/specsheet/3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf

6. For Occupacy sensors selection guide, please refer : Sensor_Selection_Tool.pdf and for application guide, refer : HCS_Sensor_B.pdf

See document link: https://hubbellcdn.com/literature/Sensor_Selection_Tool.pdf

See document link: https://hubbellcdn.com/brochure/HCS_Sensor_B.pdf

7. For NXSMP-OMNI Indoor/Outdoor sensors, Please refer document OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

See link: https://hubbellcdn.com/specsheet/NX_OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

8. For NX Brochure, Please see link: https://hubbellcdn.com/brochure/HCS_NX_Brochure.pdf

9. For NX Design Application guide, Please see link: https://hubbellcdn.com/brochure/NX_Design_Application_Guide.pdf

10. MAXIMUM POWER BUDGET PER ROOM CONTROLLER OR IN-FIXTURE MODULE = +30 PBUs.

----Blank----

----Blank----

NX Bridge Module

NXHNB2

N

H1

V1

G

Violet

Gray

Red

White

CAT5/6 Cable

4x4 JUNCTION

BOX

Normal Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

12 AWG

Normal Dimming

Load 1

12 AWG

FX FX SP SP

BA

NXRCFX - 2RD

White (Neutral)

N

H1

V1

G

Gray

Red

White

18 AWG

12 AWG

Normal Dimming

Load 2

White (Neutral)

18 AWG

NXRC-1R

BA

4x4 JUNCTION

BOX

CAT5/6 Cable

Line Voltage

Receptacles

Red

White

Neutral

Switched Hot

12 AWG

Ground

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

CAT5/6 Cable

Ground

N

H1

V1

G

Violet

Gray

Red

White

White (N

eutral)

18 AWG

CAT5/6 Cable

4x4 JUNCTION

BOX

BA

Blu

e

Blu

e

Remote Test Button or

Fire Alarm interface

NXRC-UL924-UNV

Normal / Emergency Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

Cap Off

12 AWG

Normal/Emergency

Dimming Load

12 AWG

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

CAT5/6 CableCAT5/6 Cable

HubbNET NetworkHubbNET Network

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

NX Bridge Module

NXHNB2

N

H1

V1

G

Violet

Gray

Red

White

CAT5/6 Cable

4x4 JUNCTION

BOX

Normal Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

12 AWG

Normal Dimming

Load 1

12 AWG

FX FX SP SP

BA

NXRCFX - 2RD

White (Neutral)

N

H1

V1

G

Gray

Red

White

18 AWG

12 AWG

Normal Dimming

Load 2

White (Neutral)

18 AWG

N

H1

V1

G

Violet

Gray

Red

White

White (N

eutral)

18 AWG

CAT5/6 Cable

4x4 JUNCTION

BOX

BA

Blu

e

Blu

e

Remote Test Button or

Fire Alarm interface

NXRC-UL924-UNV

Normal / Emergency Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

Cap Off

12 AWG

Normal/Emergency

Dimming Load

12 AWG

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

CAT5/6 Cable

CAT5/6 Cable

HubbNET NetworkHubbNET Network

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

DRAWN BY: DATE:

DRAWING / DESIGN NO.:

SCALE:REV.

TITLE:

07/22/2020SR

0NTS

701 Millennium Blvd.

Greenville, SC 29607

www.hubbellcontrolsolutions.com

NX TYPICAL CONFIGURATIONS:

NXFX CONTROLLERS WITH DUAL LOAD (PART-1)

HCS - NX - S2

Main Switchboard: (864) 678-1000

Technical Service: (800) 888-8006

Date

By

Rev.

05/20/21 AJB

AutoCAD SHX Text
30-01249A
AutoCAD SHX Text
30-01249A
Page 3: Blank---- Typical... · 2020. 8. 31. · White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG Violet Normal Dimming Load

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Normal Power

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

NX Switch Station

NXSW-CCT

Black (Line 120/277/347 VAC)

White (Neutral)

-

N

Class 2 Driver with Max

Current of 2.5A

Red

White

H

+

+

-

+

-

CTC (Optional)

+

-

+

-

+

-

Driver

Output

0-10V

Input

0-10V

Input

Driver

Input

CH2 (+)

CH1 (+)

CH2 (+)

CH1 (+)

56VDC

Max Output

LED

Dimming Driver

(Constant Current)

For SpectraSync applications, the

highest CCT LED should be on CH1 and

the lower CCT LED should be on CH2.

Violet

Gray

Violet / Striped

Ca

p O

ff

Blue

12 AWG

18 AWG

SV

C

PW

RS

VC

P

IN

FOCUS

WORK

NORMAL

CALM

12 AWG

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Normal Power

CAT5/6 Cable

NX Switch Station

NXSW-CCT

Black (Line 120/277/347 VAC)

White (Neutral)

-

N

Class 2 Driver with Max

Current of 2.5A

Red

White

H

+

+

-

+

-

CTC (Optional)

+

-

+

-

+

-

Driver

Output

0-10V

Input

0-10V

Input

Driver

Input

CH2 (+)

CH1 (+)

CH2 (+)

CH1 (+)

56VDC

Max Output

LED

Dimming Driver

(Constant Current)

For SpectraSync applications, the

highest CCT LED should be on CH1 and

the lower CCT LED should be on CH2.

Violet

Gray

Violet / Striped

Ca

p O

ff

Blue

12 AWG

18 AWG

SV

C

PW

RS

VC

P

IN

FOCUS

WORK

NORMAL

CALM

12 AWG

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

4x4 JUNCTION

BOX

Line Voltage

Receptacles

NXRC-1R

BA

Red

White

Neutral

Switched Hot

12 AWG

Ground

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

NX Bridge Module

NXHNB2

12 AWG

CAT5/6 Cable

CAT5/6 Cable

Networked room controllers with CCT control and receptacle load

NX Bridge Module

NXHNB2

N

H1

V1

G

Violet

Gray

Red

White

CAT5/6 Cable

4x4 JUNCTION

BOX

Normal Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

12 AWG

Normal Dimming

Load 1

12 AWG

FX FX SP SP

BA

NXRCFX - 2RD

White (Neutral)

N

H1

V1

G

Gray

Red

White

18 AWG

12 AWG

Normal Dimming

Load 2

White (Neutral)

18 AWG

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

NX SMART PORT

RS232

SERIAL COM

NXAVM

NX SMART PORT

NX SMART PORT

J1

J2

Pilot

Input 2

Input 1

+24V1:

2:

3:

4:

1234

NXCI

Black (Input 1)

Brown (+24V)

Blue (Pilot)

NXWPS

NXSW-TH3

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

NX Bridge Module

NXHNB2

N

H1

V1

G

Violet

Gray

Red

White

4x4 JUNCTION

BOX

Normal Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

12 AWG

12 AWG

FX FX SP SP

BA

NXRCFX - 2RD

White (Neutral)

N

H1

V1

G

Gray

Red

White

18 AWG

12 AWG

White (Neutral)

18 AWG

NX SMART PORT

RS232

SERIAL COM

NXAVM

NXSW-TH3

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

CAT5/6 Cable

CAT5/6 Cable

CAT5/6 Cable

CAT5/6 Cable

18 AWG

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Wall / P

artition

Wall / P

artition

Wall / P

artition

Networked room controllers with partition sensor S3. C2S3. C1

Normal Dimming

Load 1

Normal Dimming

Load 2

S3. C3

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

R

HUBBELL

Building

Automation

+

-

OC

C

PC

SV

C

PW

RS

VC

P

IN

ON

OFF

NXRM-H

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

CAT5/6 Cable

18 AWG

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

R

HUBBELL

Building

Automation

+

-

OC

C

PC

SV

C

PW

RS

VC

P

IN

ON

OFF

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : WSPSM24V

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model : WSPSM24V

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

CAT5/6 Cable

18 AWG

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

S3. C4

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

R

HUBBELL

Building

Automation

+

-

OC

C

PC

Black

SV

C

PW

RS

VC

P

IN

ON

OFF

Yellow

SV

C P

IN

SV

C

PW

R

NXBTC

RJ45 Adapter

Red 24V

DC

Blue

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

CAT5/6 Cable

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

Red 24VDC

Black

Yellow

RJ45 Adapter

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

CAT5/6 Cable

Normal dimming networked load Normal dimming load Normal dimming with NXBTCS3. C5 S3. C6 Daylight sensor controlled normal dimming loadS3. C7

12 AWG 12 AWG

12 AWG 12 AWG12 AWG

18 AWG

NX Bridge Module

NXHNB2

N

H1

V1

G

Violet

Gray

Red

White

CAT5/6 Cable

4x4 JUNCTION

BOX

Normal Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

12 AWG

Normal Dimming

Load 1

12 AWG

FX FX SP SP

BA

NXRCFX - 2RD

White (Neutral)

N

H1

V1

G

Gray

Red

White

18 AWG

12 AWG

Normal Dimming

Load 2

White (Neutral)

18 AWG

S3. C8

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

12 AWG

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

CAT5/6 Cable

18 AWG

CAT5/6 Cable

NX Bridge Module

NXHNB2

N

H1

V1

G

Violet

Gray

Red

White

HubbNET NetworkHubbNET Network

CAT5/6 Cable

4x4 JUNCTION

BOX

Normal Power

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

12 AWG

Normal Dimming

Load 1

12 AWG

FX FX SP SP

BA

NXRCFX - 2RD

White (Neutral)

N

H1

V1

G

Gray

Red

White

18 AWG

12 AWG

Normal Dimming

Load 2

White (Neutral)

18 AWG

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

12 AWG

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

CAT5/6 Cable

18 AWG

CAT5/6 Cable

Owner supplied PC with

Web Browser

Ethernet

NXAC

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Hot

Blue (Control)

Black (Common)

Neutral

Ground

120 VAC

HCSREC-F

18 AWG

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

Black

Yellow

RJ45 Adapter

Red 24VDC

Blue

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

S3. C9 Normal dimming with controlled receptacle S3. C10

CAT5/6 Cable

BA

Blu

e

Blu

e

Remote Test Button or

Fire Alarm interface

Violet/Striped

Cap Off

CAT5/6 Cable

RJ45 Adapter

R

HUBBELL

Building

Automation

+

-

OC

C

PC

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

(Additonal sensors if required)

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

18 AWG

CAT5/6 Cable

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

4x4 JUNCTION

BOX

NXRC-UL924-UNV

Violet

Gray

Red

White

G

V

H

N

18 AWG

Black (Line 120/277/347 V

AC

)

White (N

eutral)

12 AWG

Normal /

Emergency Power

Normal/Emergency

Dimming Load

4x4 JUNCTION

BOX

FX FX SP SP

BA

NXRCFX - 2RD

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

G

V1

H1

N

N

H2

V2

G

Normal Dimming

Load 1

Normal Dimming

Load 2

Violet

Gray

Red

White

Gray

White

Blue

Violet/Striped

12 AWG

18 AWG

12 AWG

Neutral

12 AWG

12 AWG12 AWG

Normal/Emergency dimming load on NX UL924 room controller

Networked room controllers with NX area controller

CAT5/6 Cable

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

Occupancy sensor controlled normal dimming load

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-ORLO

NX Switch Station

Typical Model :

NXSW-6

Photo Sensor

NXDS

Photo Sensor

NXDS

Photo Sensor

NXDS

Photo Sensor

NXDS

(As required)

Refer to Detail-5

in drawing no.

HCS - NX - S4

(As required)

(As required) (As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

(As required)

(As required)

(As required)

(As required) (As required)(As required)

(As required)

(As required)

(As required)

(As required) (As required)

(As required)

(As required)

(As required)

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 CableCAT5/6 Cable

CAT5/6 CableCAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

CAT5/6 Cable

Ground

CAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S4

CAT5/6 CableCAT5/6 Cable

CAT5/6 CableCAT5/6 Cable

HubbNET NetworkHubbNET Network

HubbNET NetworkHubbNET Network

HubbNET NetworkHubbNET Network

HubbNET NetworkHubbNET Network

CA

T5/6 C

able

Notes

1. For Power budget of Room controllers and device loads, Please refer "3451B_NX_Room_Controller_Install_and_Operation.pdf".

See document link:https://hubbellcdn.com/installationmanuals/3451B_NX_Room_Controller_Install_and_Operation.pdf. (See Note 10 below)

2. For NX Smart switches (NXSW-1 upto NXSW-6 switch stations), each buttons on the station maybe programmed for different functions as desired

using NX Device Setup App. Please refer 3457.1A_NX_Smart_Switch.pdf

See document link: https://hubbellcdn.com/specsheet/3457.1A_NX_Smart_Switch.pdf

3. For NX Speciality switches (NXSW-OO/ ORLO / RL switch stations), please refer 3457.2A_NX_Specialty_Switches.pdf

See document link: https://hubbellcdn.com/specsheet/3457.2A_NX_Specialty_Switches.pdf

4. For guide on NX Switch stations, please refer HCS_NX_Switch_Guide.pdf.

See document link: https://hubbellcdn.com/literature/HCS_NX_Switch_Guide.pdf

5. For NX Occupancy sensors, please refer 3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf and

3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf.

See document link: https://hubbellcdn.com/specsheet/3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf

See document link:: https://hubbellcdn.com/specsheet/3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf

6. For Occupacy sensors selection guide, please refer : Sensor_Selection_Tool.pdf and for application guide, refer : HCS_Sensor_B.pdf

See document link: https://hubbellcdn.com/literature/Sensor_Selection_Tool.pdf

See document link: https://hubbellcdn.com/brochure/HCS_Sensor_B.pdf

7. For NXSMP-OMNI Indoor/Outdoor sensors, Please refer document OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

See link: https://hubbellcdn.com/specsheet/NX_OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

8. For NX Brochure, Please see link: https://hubbellcdn.com/brochure/HCS_NX_Brochure.pdf

9. For NX Design Application guide, Please see link: https://hubbellcdn.com/brochure/NX_Design_Application_Guide.pdf

10. MAXIMUM POWER BUDGET PER ROOM CONTROLLER OR IN-FIXTURE MODULE = +30 PBUs.

----Blank----

----Blank----

Yellow

DRAWN BY: DATE:

DRAWING / DESIGN NO.:

SCALE:REV.

TITLE:

07/23/2020SR

0NTS

701 Millennium Blvd.

Greenville, SC 29607

www.hubbellcontrolsolutions.com

NX TYPICAL CONFIGURATIONS:

NXFX CONTROLLERS WITH DUAL LOAD (PART-2)

HCS - NX - S3

Main Switchboard: (864) 678-1000

Technical Service: (800) 888-8006

Date

By

Rev.

05/20/21 AJB

AutoCAD SHX Text
30-XXXX7A
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
J1
AutoCAD SHX Text
9600
AutoCAD SHX Text
19200
AutoCAD SHX Text
38400
AutoCAD SHX Text
115200
AutoCAD SHX Text
BAUD RATE
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
S2
AutoCAD SHX Text
POWER
AutoCAD SHX Text
NXAVM
AutoCAD SHX Text
30-01249A
AutoCAD SHX Text
30-XXXX7A
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
J1
AutoCAD SHX Text
9600
AutoCAD SHX Text
19200
AutoCAD SHX Text
38400
AutoCAD SHX Text
115200
AutoCAD SHX Text
BAUD RATE
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
S2
AutoCAD SHX Text
POWER
AutoCAD SHX Text
NXAVM
Page 4: Blank---- Typical... · 2020. 8. 31. · White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG Violet Normal Dimming Load

Notes

NXFM-1R2D-O-UNV

Gray (-)

Violet/White (+) CH 2

Black (Line 120/277/347 V

AC

)

Normal Power

Red

White

Black

Test Button

Test LED

Violet (+) Ch 1

0-10v Dimming

18 AWG12 AWG

12 AWG

NXRM-H

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

NXFSP

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

CAT5/6 Cable

NXCBL Cable

NX fixture module (Offset) with dual driversS4. C1

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

NXFSP

CAT5/6 Cable

NXCBL Cable

Test LED

Test Button

NXFM-1R2D-I-UNV

Gray (-)

Violet/White (+) CH 2

Violet (+) Ch 1

Black

White

Red

0-10v Dimming

LED Dimming

Driver 2

N

H

+H

N

LED Dimming

Driver 1

-

-

+

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

12 AWG

18 AWG12 AWG

NX fixture module (Inline) with dual driversS4. C2

Violet (+

) C

h 1

Violet/W

hite (+

) C

H 2

Com

mon

+12V

COM

Dim2

Dim1

Test LED

NXFM-LV

Test Button

+12 V

DC

LED Dimming

Driver 2

N

H

+H

N

LED Dimming

Driver 1

-

-

+

LED Dimming

Driver 1

COM

+

H

N

+12V

LED Dimming

Driver 2

COM

+

H

N

+12V

Black (Line)

White (Neutral)

Black (Line)

White (Neutral)

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

NXFSP

CAT5/6 Cable

NX fixture module (Low Voltage) with dual driversS4. C3

Cap Off

Black (Line In)

White (N

eutral/Line 2 In)

Red (line O

ut)

Violet (0-10V

) +

O

ut

Gray (0-10V

) - G

ND

O

ut

Brow

n (24V

DC

)

Orange (D

igital In 3-30V

DC

)

Low Voltage

Occupancy Sensor

Typical Model : WSPSM24V

Violet

Normal Dimming

Load

Gray

Red

White

G

V

H

N

Blue (Control)

Red

Black

Normal Power

Line 120/277/347/480 VAC

Neutral

NX on-fixture module (7 Pin)

POWERED

HubNET

NETWORK

NON

POWERED

ETHERNET

NETWORK

4 3 2 15

DC IN

Solid State Drive

See Side Profile

View A for Detail

Mother Board

Power Supply

Profile View

Detail A

See Side Profile

View B for Detail

Profile View

Detail B

DB-15HD, 15-pin

(Not Used)

6-pin female

mini DIN

DVI Video

(Not Used)

DB-9, 9-pin male

(Not Used)

PC/Network Connection

Miniplug(s)

(Not Used)

USB

(4-Typical)

RJ-45, 8-pin female

RJ-45 connection between Port

1 and Mother Board RJ-45 Port

MB-5 (Detail B)

RJ-45 connection between this

Port and Port 1 on Detail A

Battery for Clock Back-up

e-SATA Connector

(Connects to Hard Drive)

MB-6

MB-5

MB-4

MB-3

MB-2

MB-1

MB-6

MB-5

MB-4

MB-3

MB-2

MB-1

12V Power to

MotherBoard

High Voltage

Compartment

12V

24V IN

5V

Use for HUBBNET connection to NX Panels

only. This port does not supply power to the

network.

Use for HUBBNET connections to NX panels

or NXHNB bridges. This port supplies power

to the network.

Detail-5: NXAC

Details

Note:

1. To connect an NXSMP sensors or NXRM-H radio to a T568B standard CAT5/6 cable using an

RJ45 connector it is necessary to use the NXCBL-P-10 plenum accessory cable to bridge the

sensor to the CAT5/6 connector.

2. NXSMP sensors and NXRM-H radios have two connection terminals to achieve daisy chaining

to other NXFX devices.

NXCBL-P-10

CAT5/6 Cable

NXSMP or NXRM-H

Detail-1 : NXRM-H/NXSMP to CAT5/6 cable

4x4 JUNCTION

BOX

NXRC-1R

BA

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

NX Bridge Module

NXHNB2

NXRM-H

CAT5/6 Cable

N

Normal

Load

Red

White

H

12 AWG

Owner supplied PC with Web

Browser

Ethernet

NXFM-1R2D-O-UNV

Gray (-)

Violet/White (+) CH 2

Black (Line 120/277/347 V

AC

)

Normal Power

Red

White

Black

Test Button

Test LED

Violet (+) Ch 1

0-10v Dimming

18 AWG12 AWG

12 AWG

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

NXFSP

NXCBL Cable

LED Dimming

Driver 2

N

H

+H

N

LED Dimming

Driver 1

-

-

+

NXRM-H

NXFM-1R2D-O-UNV

Gray (-)

Violet/White (+) CH 2

Black (Line 120/277/347 V

AC

)

Normal Power

Red

White

Black

Test Button

Test LED

Violet (+) Ch 1

0-10v Dimming

18 AWG12 AWG

12 AWG

Low Voltage

Occupancy Sensor

Typical Model :

NXSMP-OMNI

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

NXFSP

NXCBL Cable

LED Dimming

Driver 2

N

H

+H

N

LED Dimming

Driver 1

-

-

+

NXRM-H

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

Refer to Detail-6

for NX-8 details

on drawing

(HCS-NX-S7)

NX-Panel

Typical Model : NXP2-8

HubbNET Network

HubbNET Network

Detail-6:Detail-2 : NXOFM

Compliant with:

ANSI C136-41 (7& 5 pin) twist-lock receptacles.

Receptacle not included.

Bottom View

Refer to Detail-2

in this drawing

(HCS-NX-S4)

S4. C9

To NX network / Next Fixture

as applicable

To NX network / Next Fixture

as applicable

To NX network / Next Fixture

as applicable

Owner supplied PC with Web

Browser

Ethernet

NXAC

NX-EOF-MC-01

PoE 1

MODE A

48 V

24 V

MODE B

48 V

24 V

PoE 2 PoE 3 PoE 4 PoE 5 PoE 6 PoE 7 UP LINK

NXPOE7-24B

4x4 JUNCTION

BOX

NX Bridge Module

NXHNB2

Connection to N

on P

ow

ered E

thernet P

ort of N

XA

C

Connection to U

plink P

ort

Black (Line 120 V

AC

)

White (N

eutral)

AC Adapter

5-12 VDC

HubbNET Network HubbNET Network

Next B

uilding

Building -1Building -2

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

Wireless network of NX devices with NX area controller and panels

4x4 JUNCTION

BOX

NX Bridge Module

NXHNB2

HubbNET Network

PoE 1

MODE A

48 V

24 V

MODE B

48 V

24 V

PoE 2 PoE 3 PoE 4 PoE 5 PoE 6 PoE 7 UP LINK

NXPOE7-24B

To NX network of Building 2

To NX network of Building 1

NX-EOF-MC-01

Black (Line 120 V

AC

)

White (N

eutral)

AC Adapter

5-12 VDC

Next B

uilding

Next B

uilding

Copper Ethernet

Copper Ethernet

Network of NX devices between two separate building units via fiber cable and media converter

Fiber

Fiber

Yellow

White (N

eutral)

White (N

eutral)

White (N

eutral)

NXAC

NX-Panel

Typical Model : NXP2-8

Building Automation

HUBBELL

HUBBELL

R

HubbN

ET

N

etw

ork

Photo Sensor

(LUXSTATLS)

Pin 1

Pin 2

Pin 3

Pin 4

LED

COMMON

CONTROL

+24VDC

Pin 1

Pin 2

Pin 3

Pin 4

NORMALLY OPEN

COMMON

COMMON

NORMALLY CLOSED

Pin 1

Pin 2

Pin 3

Pin 4

Detail-3 : NXDCIO

Refer to Detail-3

in this drawing

(HCS-NX-S4)

Red 24VDC

Black

SV

C

PW

RS

VC

P

IN

LVSM2PL

Switch Station

Black

Blue

Gray

Black/White

Blue/White

Gray/White

Low Voltage

Occupancy Sensor

Typical Model : WSPSM24V

Low Voltage

Occupancy Sensor

Typical Model : WSPSM24V

Red 24VDC

NXDCIO with NXHDIS4. C5

NXHDI NXDCIO

Blue

Black

Red 24VDC

Blue

Black

S4. C4

S4. C8

18 AWG

18 AWG

Details Details Details

Building Automation

HUBBELL

HUBBELL

R

Red 24VDC

Black

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

18 AWGRJ45 Adapter

Neutral

Line 100-270 VAC

NXHDI NXSP

HubbN

ET

N

etw

ork

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

SV

C P

IN

SV

C

PW

R

NX Switch Station

Typical Model :

NXSW-6

CAT5/6 Cable

CAT5/6 Cable

CAT5/6 Cable

Yellow

NXSP with NXHDIS4. C6

NXHDI required for connection to HubbNET network

(DIN rail devices typically located in NXENC-D)

4x4 JUNCTION

BOX

NXRC-1R

BA

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

NX Bridge Module

NXHNB2

NXRM-H

N

Normal

Load

Red

White

H

12 AWG

Ethernet

NXAC

Refer to Detail-5

in this drawing

(HCS-NX-S4)

Networked controller connected to NX area controllerS4. C7

+

S-

VOUT

ADJ

DC

LO

DC

OK

NL

DSP

30-24/277A

NXPWRSPLY

Red

White

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

Black

Yellow

RJ45 Adapter

Red 24VDC

Blue

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

drawing

CAT5/6 Cable

Neutral

Line 100-270 VAC

+

S-

VOUT

ADJ

DC

LO

DC

OK

NL

DSP

30-24/277A

NXPWRSPLY

Red

White

NOTES:1. Four (4) ports total, each with two (2) RJ45 connectors.

Upper and lower RJ45 port connectors are internallyconnected in parallel

2. Maximum power budget per SmartPort module = 32Loads

Switch station = 1 LoadPIR only Occupancy sensor = 1 LoadPIR only Occupancy sensor with RP option = 2 LoadsDual Technology and Ultrasonic Occupancy sensor = 3LoadsDual Technology and Ultrasonic Occupancy sensor withRP option = 4 LoadsDaylight Sensor (photocell) = 1 Load

3. The entire power budget can be used on one (1) port ordistributed across all four (4) ports

4. Only one (1) Daylight Sensor is supported per port, four(4) maximum per SmartPort Module

5. Multiple Occupancy Sensors can be connected to a singleport, but all will be programmed into a single Zone. TheSmartPort Module supports a maximum of four (4)Occupancy Zones total regardless of the number ofOccupancy Sensors connected.

6. A maximum of eight (8) Smart Switches can be connectedto each port (32 maximum per module) and my share aport with a Daylight Sensor or Occupancy Sensor(s)

7. NXPWRSPLY power supply is required for each location ifmore than one (1) SmartPort module total is connectedto the HubbNET network wire

Refer to Detail-4

in this drawing

(HCS-NXS-S4)

Owner supplied PC with Web

Browser

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing power

budget of controller.

Please refer to notes section in this

drawing

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

NXFM-O

Max Power budget

per NXFM-O is 30

NXFM-I

Max Power budget

per NXFM-I is 30

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing power

budget of controller.

Please refer to notes section in this

drawing

NXFM-O

Max Power budget

per NXFM-O is 30

NXFM-O

Max Power budget

per NXFM-O is 30

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

NXFM- LV

Max Power budget

per NXFM-LV is

depended on the

driver powering the

NXFM-LV

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing power

budget of controller.

Please refer to notes section in this

drawing

HubbNET Network

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

Photo Sensor

NXDS

NXOFM

The on-fixture module is intended to control a

single fixture.

Control input devices connecting to the NXOFM

do not support SmartPORT connections.

Available power for control input devices is

based on the luminaire driver capacity.

Detail-4 : NXSP

NXHDI required for connection to HubbNET network

(DIN rail devices typically located in NXENC-D)

(As required)

(As required)

(As required)

(As required)

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-ORLO

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

drawing

NXRM-H

NXRM-H

NXCBL + CAT5/6 Cable

Refer to Detail-1

in this drawing

(HCS - NX - S4)

NXCBL + CAT5/6 Cable

Refer to Detail-1

in this drawing

(HCS - NX - S4)

NXCBL + CAT5/6 Cable

Refer to Detail-1

in this drawing

(HCS - NX - S4)

CAT5/6 Cable

HubbNET Network

CAT5/6 Cable

HubbNET Network

CAT5/6 Cable CAT5/6 Cable CAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in this drawing

(HCS - NX - S4)

CAT5/6 CableCAT5/6 Cable

CAT5/6 Cable

CA

T5/6 C

able

CA

T5/6 C

able

CAT5/6 Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in this drawing

(HCS - NX - S4)

NXCBL + CAT5/6 Cable

Refer to Detail-1

in this drawing

(HCS - NX - S4)

NXCBL Cable

NXCBL + CAT5/6 Cable

Refer to Detail-1

in this drawing

(HCS - NX - S4)

Refer to Detail-5

in this drawing

(HCS-NX-S4)

Refer to Detail-5

in this drawing

(HCS-NX-S4)

1. For Power budget of Room controllers and device loads, Please refer "3451B_NX_Room_Controller_Install_and_Operation.pdf".

See document link:https://hubbellcdn.com/installationmanuals/3451B_NX_Room_Controller_Install_and_Operation.pdf. (See Note 10 below)

2. For NX Smart switches (NXSW-1 upto NXSW-6 switch stations), each buttons on the station maybe programmed for different functions as desired

using NX Device Setup App. Please refer 3457.1A_NX_Smart_Switch.pdf

See document link: https://hubbellcdn.com/specsheet/3457.1A_NX_Smart_Switch.pdf

3. For NX Speciality switches (NXSW-OO/ ORLO / RL switch stations), please refer 3457.2A_NX_Specialty_Switches.pdf

See document link: https://hubbellcdn.com/specsheet/3457.2A_NX_Specialty_Switches.pdf

4. For guide on NX Switch stations, please refer HCS_NX_Switch_Guide.pdf.

See document link: https://hubbellcdn.com/literature/HCS_NX_Switch_Guide.pdf

5. For NX Occupancy sensors, please refer 3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf and

3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf.

See document link: https://hubbellcdn.com/specsheet/3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf

See document link:: https://hubbellcdn.com/specsheet/3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf

6. For Occupacy sensors selection guide, please refer : Sensor_Selection_Tool.pdf and for application guide, refer : HCS_Sensor_B.pdf

See document link: https://hubbellcdn.com/literature/Sensor_Selection_Tool.pdf

See document link: https://hubbellcdn.com/brochure/HCS_Sensor_B.pdf

7. For NXSMP-OMNI Indoor/Outdoor sensors, Please refer document OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

See link: https://hubbellcdn.com/specsheet/NX_OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

8. For NX Brochure, Please see link: https://hubbellcdn.com/brochure/HCS_NX_Brochure.pdf

9. For NX Design Application guide, Please see link: https://hubbellcdn.com/brochure/NX_Design_Application_Guide.pdf

10. MAXIMUM POWER BUDGET PER ROOM CONTROLLER OR IN-FIXTURE MODULE = +30 PBUs.

CA

T5/6 C

able

CAT5/6 Cable

CAT5/6 Cable

CA

T5/6 C

able

CA

T5/6 C

able

CA

T5/6 C

able

CA

T5/6 C

able

----Blank----

----Blank----

----Blank----

DRAWN BY: DATE:

DRAWING / DESIGN NO.:

SCALE:REV.

TITLE:

08/04/2020SR

0NTS

701 Millennium Blvd.

Greenville, SC 29607

www.hubbellcontrolsolutions.com

NX TYPICAL CONFIGURATIONS:

OTHER NX DEVICES

HCS - NX - S4

Main Switchboard: (864) 678-1000

Technical Service: (800) 888-8006

Date

By

Rev.

02/18/21 AJA 05/20/21 AJB

AutoCAD SHX Text
MODULE CONN IN
AutoCAD SHX Text
D2
AutoCAD SHX Text
D1
AutoCAD SHX Text
PWR
AutoCAD SHX Text
MODULE CONN OUT
AutoCAD SHX Text
IO PORT 1
AutoCAD SHX Text
IO PORT 2
AutoCAD SHX Text
IO PORT 3
AutoCAD SHX Text
IO PORT 4
AutoCAD SHX Text
IO PORT 5
AutoCAD SHX Text
IO PORT 6
AutoCAD SHX Text
RELAY 1
AutoCAD SHX Text
RELAY 2
AutoCAD SHX Text
RELAY 3
AutoCAD SHX Text
RELAY 4
AutoCAD SHX Text
RELAY 5
AutoCAD SHX Text
RELAY 6
AutoCAD SHX Text
NO
AutoCAD SHX Text
COM
AutoCAD SHX Text
COM
AutoCAD SHX Text
NC
AutoCAD SHX Text
DRY CONTACT RELAY
AutoCAD SHX Text
+24V
AutoCAD SHX Text
CTRL
AutoCAD SHX Text
COM
AutoCAD SHX Text
LED
AutoCAD SHX Text
IO PORT
AutoCAD SHX Text
NETWORKED
AutoCAD SHX Text
Lighting Controls
AutoCAD SHX Text
LINK
AutoCAD SHX Text
D2
AutoCAD SHX Text
D1
AutoCAD SHX Text
24V-
AutoCAD SHX Text
24V+
AutoCAD SHX Text
POWER LED
AutoCAD SHX Text
POWERED HUBBNET IN/OUT
AutoCAD SHX Text
LINK
AutoCAD SHX Text
NETWORKED
AutoCAD SHX Text
Lighting Controls
AutoCAD SHX Text
MODULE CONNECTOR OUT
AutoCAD SHX Text
MODULE CONN IN
AutoCAD SHX Text
D2
AutoCAD SHX Text
D1
AutoCAD SHX Text
PWR
AutoCAD SHX Text
MODULE CONN OUT
AutoCAD SHX Text
IO PORT 1
AutoCAD SHX Text
IO PORT 2
AutoCAD SHX Text
IO PORT 3
AutoCAD SHX Text
IO PORT 4
AutoCAD SHX Text
IO PORT 5
AutoCAD SHX Text
IO PORT 6
AutoCAD SHX Text
RELAY 1
AutoCAD SHX Text
RELAY 2
AutoCAD SHX Text
RELAY 3
AutoCAD SHX Text
RELAY 4
AutoCAD SHX Text
RELAY 5
AutoCAD SHX Text
RELAY 6
AutoCAD SHX Text
NO
AutoCAD SHX Text
COM
AutoCAD SHX Text
COM
AutoCAD SHX Text
NC
AutoCAD SHX Text
DRY CONTACT RELAY
AutoCAD SHX Text
+24V
AutoCAD SHX Text
CTRL
AutoCAD SHX Text
COM
AutoCAD SHX Text
LED
AutoCAD SHX Text
IO PORT
AutoCAD SHX Text
NETWORKED
AutoCAD SHX Text
Lighting Controls
AutoCAD SHX Text
+24V
AutoCAD SHX Text
CTRL
AutoCAD SHX Text
COM
AutoCAD SHX Text
LED
AutoCAD SHX Text
IO PORT
AutoCAD SHX Text
LINK
AutoCAD SHX Text
D2
AutoCAD SHX Text
D1
AutoCAD SHX Text
MODULE CONNECTOR OUT
AutoCAD SHX Text
24V-
AutoCAD SHX Text
24V+
AutoCAD SHX Text
POWER LED
AutoCAD SHX Text
POWERED HubbNET IN/OUT
AutoCAD SHX Text
LINK
AutoCAD SHX Text
NETWORKED
AutoCAD SHX Text
Lighting Controls
AutoCAD SHX Text
NETWORKED
AutoCAD SHX Text
Lighting Controls
AutoCAD SHX Text
MODULE CONN IN
AutoCAD SHX Text
PWR
AutoCAD SHX Text
+
AutoCAD SHX Text
-
AutoCAD SHX Text
D2
AutoCAD SHX Text
D1
AutoCAD SHX Text
MODULE CONN OUT
AutoCAD SHX Text
PORT 1
AutoCAD SHX Text
PORT 2
AutoCAD SHX Text
PORT 3
AutoCAD SHX Text
PORT 4
AutoCAD SHX Text
PORT 1
AutoCAD SHX Text
PORT 2
AutoCAD SHX Text
PORT 3
AutoCAD SHX Text
PORT 4
AutoCAD SHX Text
+24V DC
AutoCAD SHX Text
NETWORKED
AutoCAD SHX Text
Lighting Controls
AutoCAD SHX Text
MODULE CONN IN
AutoCAD SHX Text
PWR
AutoCAD SHX Text
+
AutoCAD SHX Text
-
AutoCAD SHX Text
D2
AutoCAD SHX Text
D1
AutoCAD SHX Text
MODULE CONN OUT
AutoCAD SHX Text
PORT 1
AutoCAD SHX Text
PORT 2
AutoCAD SHX Text
PORT 3
AutoCAD SHX Text
PORT 4
AutoCAD SHX Text
PORT 1
AutoCAD SHX Text
PORT 2
AutoCAD SHX Text
PORT 3
AutoCAD SHX Text
PORT 4
AutoCAD SHX Text
+24V DC
AutoCAD SHX Text
PORT 1
AutoCAD SHX Text
PORT 1
Page 5: Blank---- Typical... · 2020. 8. 31. · White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG Violet Normal Dimming Load

BA

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NXRC- 1R

4x4 JUNCTION

BOX

SV

C

PW

RS

VC

P

IN

ON

OFF

R

HUBBELL

Building

Automation

+

-

OC

C

PC

Black

RJ45 Adapter

Red 24V

DC

Blue

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

CAT5/6 Cable

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

NX Switch Station

Typical Model :

NXSW-4

NXBTC

CAT5/6 Cable

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

H

12 AWG 12 AWG

Normal

Load

Red

White

Red 24VDC

Black

Yellow

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

CAT5/6 Cable

18 AWG

RJ45 Adapter

SV

C

PW

RS

VC

P

IN

BA

Blu

e

Blu

e

Remote Test Button or

Fire Alarm interface

Violet/Striped

Cap Off

4x4 JUNCTION

BOX

NXRC-UL924-UNV

Violet

Gray

Red

White

G

V

H

N

18 AWG

Black (Line 120/277/347 V

AC

)

White (N

eutral)

12 AWG

Normal /

Emergency Power

Normal/Emergency

Dimming Load

12 AWG

Normal / Emergency Dimming load on NXRC-UL924 Room Controller

CAT5/6 Cable

NX Bridge Module

NXHNB2

HubbNET NetworkHubbNET Network

CAT5/6 Cable

4x4 JUNCTION

BOX

BA

CAT5/6 Cable

BA

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NXRC- 1R

SV

C

PW

RS

VC

P

IN

ON

OFF

R

HUBBELL

Building

Automation

+

-

OC

C

PC

Black

RJ45 Adapter

Red 24V

DC

Blue

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

CAT5/6 Cable

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

NX Switch Station

Typical Model :

NXSW-4

N

H

12 AWG

Normal

Load

Red

White

SV

C

PW

RS

VC

P

IN

Networked Normal / Emergency Dimming load on NXRC-UL924 Room Controller

R

HUBBELL

Building

Automation

+

-

OC

C

PC

BA

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

CAT5/6 Cable

18 AWG

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NXRC- 1R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

S5. C1 Normal switching load

N

Normal

Load

Red

White

H

12 AWG

SV

C

PW

RS

VC

P

IN

ON

OFF

BA

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NXRC- 1R

4x4 JUNCTION

BOX

SV

C

PW

RS

VC

P

IN

ON

OFF

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : WSPSM24V

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : WSPSM24V

18 AWG

Normal switching load with WASP Sensor

BA

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NXRC- 1R

4x4 JUNCTION

BOX

SV

C

PW

RS

VC

P

IN

ON

OFF

Normal switching load with NXBTC

CAT5/6 Cable

R

HUBBELL

Building

Automation

+

-

OC

C

PC

Black

RJ45 Adapter

Red 24V

DC

Blue

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

CAT5/6 Cable

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

NXBTC

CAT5/6 Cable

R

HUBBELL

Building

Automation

+

-

OC

C

PC

BA

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

NXRC- 1R

4x4 JUNCTION

BOX

BA

NXRC- 1R

4x4 JUNCTION

BOX

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

CAT5/6 Cable

Blue (Test Loop)

ALCR1277

Emergency Light Controller

(Red)

Emergency Pow

Output On

Black

(Green)

Normal Power

Blue (Test Loop)

Purple (Dimmer Loop)

Purple (Dimmer Loop)

White

Red

Red

Gray

Black

C

Cntrl.

H

NNormal

Load 1

H

N

Normal/Emergency

Load 1

To Optional Remote

Test Switch

Norm

al/E

mergency S

witched

Normal/Emergency (Line 120/277 VAC)

Normal/Emergency (Neutral)

Normal/Emergency Power

Neutral

Line

Line

Neutral

Line 120/270 VAC

Neutral

Normal Switched

12 AWG

Black (Line 120/277 V

AC

)

White (N

eutral)

12 AWG

Normal Power

Black

White

Red

Red

Gray

Black

16 AWG

12 AWG

12 AWG

16 AWG

16 AWG

16 AWG

Normal Switched

Normal Neutral

12 AWG

12 AWG

Normal / Emergency load with ALCR1277

12 AWG

BA

NXRC- 1R

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

CAT5/6 Cable

TEST SWITCH

EMERGENCY

POWER

UTILITY

POWER

UL924EPC1D-UNVEmergency LightLoad Controller

1 Black (120V)

2 Orange (277V)

4 White

3 Red

6 Yellow

7 White/Blue

Normal/Emergency (Line -120/277 VAC)

Normal/Emergency Neutral

Norm

al/E

mergency S

witched

5 Blue

Select

connection

wire

based on

voltage

Black

Blue

(+0-10V In)

Red

(+0-10V Out)

Cap off

Plenum

Low

Voltage

Wiring

Line 120V/277 VAC

Neutral

Normal Switched

Normal/Emergency Power

12 AWG

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

12 AWG

Normal / Emergency load with UL924EPC1D-UNV

BA

NXRC- 1R

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

CAT5/6 Cable

H

N

Normal/Emergency

Load 1

#3

B

lu

e

#1

2 B

lu

e

#1 Orange

UTILITY

EMERGENCY

STATUS

TEST

SET

#4

W

hite

/B

lu

e

#1

3 W

hite

/B

lu

e

UL1008BCELTS1277

16Amps Max.

Normal/Emergency (Line 120/277VAC)

Normal/Emergency Neutral

H

N

Normal

Load 1

#6 Red/White

#5 Red

#9 Yellow

Ca

p O

ff

Red Loop (20AWG) for use with a

Normally Closed Maintained

Fire Alarm Switch

#11 White

#2 White

#10 Black

#7 Purple (Out)

#8 Brown (In)

No

rm

al/E

me

rg

en

cy S

witch

ed

Neutral

Normal Switched

4x4 JUNCTION

BOX

Line 120/277 VAC

12 AWG

Normal/Emergency

Power

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

18 AWG

12 AWG

18 AWG

12 AWG

12 AWG

12 AWG

18 AWG

16 AWG

16 AWG

12 A

WG

12 A

WG

18 A

WG

18 A

WG

12 AWG

Normal Switched

Normal Neutral

No

rm

al/E

me

rg

en

cy N

eu

tra

l

12 AWG

12 AWG

12 AWG

Normal / Emergency load with UL1008BCELTS1277

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

Normal

Load

H

12 AWG 12 AWG

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

H

12 AWG 12 AWG

Normal

Load

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

H

12 AWG 12 AWG

Normal

Load

Red

White

Red

White

Red

White

BA

NXRC- 1R

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

4x4 JUNCTION

BOX

Black (Line 120/277 V

AC

)

White (N

eutral)

12 AWG

N

Red

White

H

Neutral

Line

4

3

#UL924SR1

#UL924SR2

Bypass Shunt Relay

Shunt

Line

1

2

Normal/Emergency

Load

Normal /

Emergency Power

Normal Power

Black (Line 120/277 V

AC

)

White (N

eutral)

S5. C9 Normal / Emergency load with UL924SRx

12 AWG

12 AWG

4x4 JUNCTION

BOX

Line Voltage

Receptacles

NXRC-1R

BA

CAT5/6 Cable

Normal switching load and receptacle load

Red

White

Neutral

Switched Hot

12 AWG

Ground

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

12 AWG

R

HUBBELL

Building

Automation

+

-

OC

C

PC

BA

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

NXRC- 1R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

H

12 AWG 12 AWG

Normal

Load

Red

White

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

Red 24VDC

Black

Yellow

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

CAT5/6 Cable

18 AWG

BA

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

NX Wall Station. (NXSW)

The NXSW wall station shown is for representation purposes.

Additional switches can be daisy chained using similar wiring

up to 'X' nos. observing power budget of controller.

Please refer to notes section in this document

NXRC- 1R

4x4 JUNCTION

BOX

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

Black (Line 120/277/347 V

AC

)

White (N

eutral)

N

H

12 AWG 12 AWG

Normal

Load

Red

White

R

HUBBELL

Building

Automation

+

-

OC

C

PC

Black

Yellow

RJ45 Adapter

Red 24V

DC

CAT5/6 Cable

18 AWG

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

Red 24VDC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Hot

Blue (Control)

Black (Common)

Neutral

Ground

120 VAC

18 AWG

HCSREC-F

+

-

OCC

PC

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on application and requirement.

Additional sensors can be added in the daisy chain up to 'X'

nos. observing power budget of controller.

Please refer to notes section in this document

RJ45 Adapter

RJ45 Adapter

18 AWG

Normal switching load with controlled receptacle

Normal Power

R

HUBBELL

Building

Automation

+

-

OC

C

PC

BA

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

CAT5/6 Cable

18 AWG

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NXRC- 1R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

Normal

Load

Red

White

H

12 AWG

SV

C

PW

RS

VC

P

IN

ON

OFF

12 AWG

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-1

Cap off

Cap off

NXRM-H

Photo Sensor

NXDS

Networked normal switching loadS5. C2Occupancy sensor controlled normal switching load

ALCR1277

The Gauge number near to lead color of this

device are the gauge size of wires coming out

of the device. Please refer to specification and

install cut sheets.

UL1008BCELTS1277

The Gauge number near to lead numbers and

lead color of this device are the gauge size of

wires coming out of the device. Please refer to

specification and install cut sheets.

Red 24VDC

Black

Yellow

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

CAT5/6 Cable

18 AWG

RJ45 Adapter

S5. C6 S5. C7 S5. C8

S5. C3 S5. C4 S5. C5

S5. C10 S5. C11

S5. C12 S5. C13

H

NNormal

Load 1

H

N

Normal/Emergency

Load 1

Neutral

Line

Line

Neutral

12 AWG

Normal Switched

Normal Neutral

12 AWG

Photo Sensor

NXDS

Photo Sensor

NXDS

Photo Sensor

NXDS

Photo Sensor

NXDS

(As required)

NXCBL + CAT5/6 Cable

Refer to Detail-1

in drawing no.

HCS - NX - S6

(As required)

(As required)(As required)

(As required)

(As required)

(As required) (As required)

(As required) (As required)

(As required)

(As required) (As required)

(As required)

(As required)

(As required) (As required)

(As required)

(As required)

(As required)

(As required)

(As required) (As required)

(As required)(As required)

(As required) (As required)

Ground

(As required)

CAT5/6 CableCAT5/6 Cable

Notes

1. For Power budget of Room controllers and device loads, Please refer "3451B_NX_Room_Controller_Install_and_Operation.pdf".

See document link:https://hubbellcdn.com/installationmanuals/3451B_NX_Room_Controller_Install_and_Operation.pdf. (See Note 10 below)

2. For NX Smart switches (NXSW-1 upto NXSW-6 switch stations), each buttons on the station maybe programmed for different functions as desired

using NX Device Setup App. Please refer 3457.1A_NX_Smart_Switch.pdf

See document link: https://hubbellcdn.com/specsheet/3457.1A_NX_Smart_Switch.pdf

3. For NX Speciality switches (NXSW-OO/ ORLO / RL switch stations), please refer 3457.2A_NX_Specialty_Switches.pdf

See document link: https://hubbellcdn.com/specsheet/3457.2A_NX_Specialty_Switches.pdf

4. For guide on NX Switch stations, please refer HCS_NX_Switch_Guide.pdf.

See document link: https://hubbellcdn.com/literature/HCS_NX_Switch_Guide.pdf

5. For NX Occupancy sensors, please refer 3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf and

3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf.

See document link: https://hubbellcdn.com/specsheet/3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf

See document link:: https://hubbellcdn.com/specsheet/3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf

6. For Occupacy sensors selection guide, please refer : Sensor_Selection_Tool.pdf and for application guide, refer : HCS_Sensor_B.pdf

See document link: https://hubbellcdn.com/literature/Sensor_Selection_Tool.pdf

See document link: https://hubbellcdn.com/brochure/HCS_Sensor_B.pdf

7. For NXSMP-OMNI Indoor/Outdoor sensors, Please refer document OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

See link: https://hubbellcdn.com/specsheet/NX_OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

8. For NX Brochure, Please see link: https://hubbellcdn.com/brochure/HCS_NX_Brochure.pdf

9. For NX Design Application guide, Please see link: https://hubbellcdn.com/brochure/NX_Design_Application_Guide.pdf

10. MAXIMUM POWER BUDGET PER ROOM CONTROLLER OR IN-FIXTURE MODULE = +30 PBUs.

----Blank----

----Blank----

N

H1

V1

G

Violet

Gray

Red

White

White (N

eutral)

4x4 JUNCTION

BOX

White (N

eutral)

Black (Line 120/277/347 V

AC

)

Violet/Striped

Cap Off

12 AWG

Normal/Emergency

Dimming Load

12 AWG

18 AWG

Normal / Emergency Power

NXRC-UL924-UNV

Yellow

DRAWN BY: DATE:

DRAWING / DESIGN NO.:

SCALE:REV.

TITLE:

08/04/2020SR

0NTS

701 Millennium Blvd.

Greenville, SC 29607

www.hubbellcontrolsolutions.com

NX TYPICAL CONFIGURATIONS:

NXRC CONTROLLERS WITH SINGLE LOAD

HCS - NX - S5

Main Switchboard: (864) 678-1000

Technical Service: (800) 888-8006

Date

By

Rev.

05/20/21 AJB

Page 6: Blank---- Typical... · 2020. 8. 31. · White (Neutral) Black (Line 120/277/347 VAC) Violet/Striped Cap Off 12 AWG Normal/Emergency Dimming Load 12 AWG Violet Normal Dimming Load

R

HUBBELL

Building

Automation

+

-

OC

C

PC

BA

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

CAT5/6 Cable

18 AWG

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NXRC- 2R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

S6. C1 Normal switching load

N

Normal

Load 1

Red

White

12 AWG 12 AWG

N

Normal

Load 2

Blue

White

H2

H1

Neutral

12 AWG

BA

NXRC- 2R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

Networked normal switching load

N

Normal

Load 1

Red

White

12 AWG 12 AWG

N

Normal

Load 2

Blue

White

H2

H1

Neutral

12 AWG

S6. C2

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2R

CAT5/6 Cable

CAT5/6 Cable

18 AWG

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NXRM-H

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

BA

NXRC- 2R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

Normal

Load 1

Red

White

12 AWG 12 AWG

N

Normal

Load 2

Blue

White

H2

H1

Neutral

12 AWG

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

SV

C

PW

RS

VC

P

IN

ON

OFF

R

HUBBELL

Building

Automation

+

-

OC

C

PC

Black

RJ45 Adapter

Red 24V

DC

Blue

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

CAT5/6 Cable

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

NXBTC

CAT5/6 Cable

Red 24VDC

Black

Yellow

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

CAT5/6 Cable

18 AWG

RJ45 Adapter

Normal switching load with NXBTC

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

BA

NXRC- 2R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

Normal

Load 1

Red

White

12 AWG 12 AWG

N

Normal

Load 2

Blue

White

H2

H1

Neutral

12 AWG

R

HUBBELL

Building

Automation

+

-

OC

C

PC

Black

RJ45 Adapter

Red 24V

DC

Blue

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

CAT5/6 Cable

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Occupancy sensor controlled normal switching load

BA

NXRC- 2R

4x4 JUNCTION

BOX

4x4 JUNCTION

BOX

Blue (Test Loop)

ALCR1277

Emergency Light Controller

(Red)

Emergency Pow

Output On

Black

(Green)

Normal Power

Blue (Test Loop)

Purple (Dimmer Loop)

Purple (Dimmer Loop)

White

Red

Red

Gray

Black

C

Cntrl.

Normal

Load 1

H

N

Normal/Emergency

Load 1

To Optional Remote

Test Switch

Norm

al/E

mergency S

witched

Normal/Emergency (Line 120/277 VAC)

Normal/Emergency (Neutral)

Normal/Emergency Power

Neutral

Line

Line

Neutral

Line 120/270 VAC

Neutral

Normal Switched

12 AWG

Black (Line 120/277 V

AC

)

White (N

eutral)

12 AWG

Normal Power

Black

White

Red

Red

Gray

Black

16 AWG

12 AWG

12 AWG

16 AWG

16 AWG

16 AWG

Normal Switched (Red)

Normal Neutral

12 AWG

12 AWG

ALCR1277

The Gauge number near to this device lead

colors are the gauge size of wires coming out

of the device. Please refer to specification and

install cut sheets.

Cap off

Normal

Load 2

N

H1

N

H2

Line

Neutral

12 AWG

Normal Switched (Blue)

Normal Neutral

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

Normal / Emergency load with ALCR1277

BA

NXRC- 2R

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

TEST SWITCH

EMERGENCY

POWER

UTILITY

POWER

UL924EPC1D-UNVEmergency LightLoad Controller

1 Black (120V)

2 Orange (277V)

4 White

3 Red

6 Yellow

7 White/Blue

N

Normal/Emergency

Load 1

Line

Neutral

Normal/Emergency (Line -120/277 VAC)

Normal/Emergency Neutral

Norm

al/E

mergency S

witched

5 Blue

Select

connection

wire

based on

voltage

Black

Blue

(+0-10V In)

Red

(+0-10V Out)

Cap off

Plenum

Low

Voltage

Wiring

Line 120V/277 VAC

Neutral

Normal Switched

Normal/Emergency Power

H

12 AWG

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

12 AWG

S6. C6 Normal / Emergency load with UL924EPC1D-UNV

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Cap off

Normal

Load 1

Neutral

Line

12 AWG

Normal Switched (Red)

Normal Neutral

Normal

Load 2

N

H1

N

H2

Line

Neutral

12 AWG

Normal Switched (Blue)

Normal Neutral

12 AWG

BA

NXRC- 2R

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

#3

B

lu

e

#1

2 B

lu

e

#1 Orange

UTILITY

EMERGENCY

STATUS

TEST

SET

#4

W

hite

/B

lu

e

#1

3 W

hite

/B

lu

e

UL1008BCELTS1277

16Amps Max.

Normal/Emergency (Line 120/277VAC)

Normal/Emergency Neutral

#6 Red/White

#5 Red

#9 Yellow

Ca

p O

ff

Red Loop (20AWG) for use with a

Normally Closed Maintained

Fire Alarm Switch

#11 White

#2 White

#10 Black

#7 Purple (Out)

#8 Brown (In)

No

rm

al/E

me

rg

en

cy S

witch

ed

Neutral

Normal Switched

4x4 JUNCTION

BOX

Line 120/277 VAC

12 AWG

Normal/Emergency

Power

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal Power

18 AWG

12 AWG

18 AWG

12 AWG

12 AWG

12 AWG

18 AWG

16 AWG

16 AWG

12 A

WG

12 A

WG

18 A

WG

18 A

WG

12 AWG

Normal Switched

Normal Neutral

No

rm

al/E

me

rg

en

cy N

eu

tra

l

12 AWG

12 AWG

12 AWG

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

UL1008BCELTS1277

The Gauge number near to lead numbers and

lead color of this device are the gauge size of

wires coming out of the device. Please refer to

specification and install cut sheets.

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

Normal Switched (Blue)

Normal Neutral

N

Normal/Emergency

Load 1

Line

Neutral

H

Normal

Load 1

Neutral

Line

Normal

Load 2

N

H1

N

H2

Line

Neutral

12 AWG

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

Normal / Emergency load with UL1008BCELTS1277

BA

NXRC- 2R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

Normal

Load 1

Red

White

12 AWG 12 AWG

N

Normal

Load 2

Blue

White

H2

H1

Neutral

12 AWG

Red 24VDC

Black

Yellow

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

CAT5/6 Cable

18 AWG

RJ45 Adapter

4x4 JUNCTION

BOX

Line Voltage

Receptacles

NXRC-1R

BA

CAT5/6 Cable

Red

White

Neutral

Switched Hot

12 AWG

Ground

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

Normal switching load and receptacle load S6. C12

BA

NXRC- 2R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

Normal

Load 1

Red

White

12 AWG 12 AWG

N

Normal

Load 2

Blue

White

H2

H1

Neutral

12 AWG

Hot

Blue (Control)

Black (Common)

Neutral

Ground

120 VAC

HCSREC-F

18 AWG

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

Black

RJ45 Adapter

Red 24VDC

Blue

18 AWG

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

Normal switching load with controlled receptacle

CAT5/6 Cable

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

Black

Yellow

Red 24VDC

18 AWG

RJ45 Adapter

CAT5/6 Cable

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

S6. C7 S6. C8

Normal / Emergency load with UL924SRx

BA

NXRC- 2R

4x4 JUNCTION

BOX

N

Red

White

12 AWG

12 AWG

H1

Neutral

Line

4

3

#UL924SR1

#UL924SR2

Bypass Shunt Relay

Shunt

Line

1

2

12 AWG

12 AWG

Normal/Emergency

Load 1

(Shunt Capable)

Black (Line 120/277 V

AC

)

White (N

eutral)

Normal /

Emergency Power

Normal Power

Black (Line 120/277 V

AC

)

White (N

eutral)

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Wall Station. (NXSW)

The NXSW wall station shown is for

representation purposes.

Additional switches can be daisy chained

using similar wiring up to 'X' nos.

observing power budget of controller.

Please refer to notes section in this

document

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

N

White

Blue

H2

12 AWG

White (N

eutral)

Normal/Emergency

Load 2

(Not Shunt)

S6. C9

S6. C11

S6. C10

Networked normal / emergency dimming load on NXRC-UL924 room controller and receptacle load

S6. C3 S6. C4

BA

NXRC- 2R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

Normal

Load 1

Red

White

12 AWG 12 AWG

N

Normal

Load 2

Blue

White

H2

H1

Neutral

12 AWG

Red 24VDC

Black

Yellow

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

CAT5/6 Cable

18 AWG

RJ45 Adapter

S6. C5 Daylight sensor controlled normal switching load

Photo Sensor

NXDS

Photo Sensor

NXDS

Photo Sensor

NXDS

Photo Sensor

NXDS

(As required) (As required) (As required) (As required)

(As required)

(As required) (As required)

(As required) (As required)

(As required) (As required)

(As required)

(As required) (As required)

(As required)

(As required) (As required)

(As required)

(As required)

(As required) (As required)

(As required)

(As required) (As required)

NXCBL + CAT5/6 Cable

Refer to Detail-1

in this drawing

(HCS - NX - S6)

Details

Note:

1. To connect an NXSMP sensors or NXRM-H radio to a T568B standard CAT5/6 cable using an RJ45 connector it is necessary to use the NXCBL-P-10

plenum accessory cable to bridge the sensor to the CAT5/6 connector.

2. NXSMP sensors and NXRM-H radios have two connection terminals to achieve daisy chaining to other NXFX devices.

NXCBL-P-10

CAT5/6 Cable

NXSMP or NXRM-H

Detail-1 : NXRM-H/NXSMP to CAT5/6 cable

Notes

1. For Power budget of Room controllers and device loads, Please refer "3451B_NX_Room_Controller_Install_and_Operation.pdf".

See document link:https://hubbellcdn.com/installationmanuals/3451B_NX_Room_Controller_Install_and_Operation.pdf. (See Note 10 below)

2. For NX Smart switches (NXSW-1 upto NXSW-6 switch stations), each buttons on the station maybe programmed for different functions as desired

using NX Device Setup App. Please refer 3457.1A_NX_Smart_Switch.pdf

See document link: https://hubbellcdn.com/specsheet/3457.1A_NX_Smart_Switch.pdf

3. For NX Speciality switches (NXSW-OO/ ORLO / RL switch stations), please refer 3457.2A_NX_Specialty_Switches.pdf

See document link: https://hubbellcdn.com/specsheet/3457.2A_NX_Specialty_Switches.pdf

4. For guide on NX Switch stations, please refer HCS_NX_Switch_Guide.pdf.

See document link: https://hubbellcdn.com/literature/HCS_NX_Switch_Guide.pdf

5. For NX Occupancy sensors, please refer 3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf and

3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf.

See document link: https://hubbellcdn.com/specsheet/3459A.1_NX_Wall_Mount_Occupancy_Sensors_Specification_Sheet.pdf

See document link:: https://hubbellcdn.com/specsheet/3459A_NX_Ceiling_Mount_Occupancy_Sensors_Specification_Sheet.pdf

6. For Occupacy sensors selection guide, please refer : Sensor_Selection_Tool.pdf and for application guide, refer : HCS_Sensor_B.pdf

See document link: https://hubbellcdn.com/literature/Sensor_Selection_Tool.pdf

See document link: https://hubbellcdn.com/brochure/HCS_Sensor_B.pdf

7. For NXSMP-OMNI Indoor/Outdoor sensors, Please refer document OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

See link: https://hubbellcdn.com/specsheet/NX_OMNI_Indoor_Sensor_Module_Specification_Sheet.pdf

8. For NX Brochure, Please see link: https://hubbellcdn.com/brochure/HCS_NX_Brochure.pdf

9. For NX Design Application guide, Please see link: https://hubbellcdn.com/brochure/NX_Design_Application_Guide.pdf

10. MAXIMUM POWER BUDGET PER ROOM CONTROLLER OR IN-FIXTURE MODULE = +30 PBUs.

BA

NXRC- 2R

4x4 JUNCTION

BOX

Black (Line 120/277/347 V

AC

)

White (N

eutral)

Normal Power

N

Normal

Load 1

Red

White

12 AWG 12 AWG

N

Normal

Load 2

Blue

White

H2

H1

Neutral

12 AWG

Red 24VDC

Black

Yellow

R

HU

BB

EL

L

Bu

ild

in

g

Au

to

ma

tio

n

+

-

OCC

PC

CAT5/6 Cable

18 AWG

RJ45 Adapter

CAT5/6 Cable

NX Switch Station

Typical Model :

NXSW-OO

SV

C

PW

RS

VC

P

IN

ON

OFF

NX Wall Station. (NXSW)

The NXSW wall station shown is for representation purposes.

Additional switches can be daisy chained using similar wiring up

to 'X' nos. observing power budget of controller.

Please refer to notes section in this document

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

NX Switch Station

Typical Model :

NXSW-4

SV

C

PW

RS

VC

P

IN

4x4 JUNCTION

BOX

Line Voltage

Receptacles

NXRC-1R

BA

CAT5/6 Cable

Red

White

Neutral

Switched Hot

12 AWG

Ground

Black (Line 120 V

AC

)

White (N

eutral)

Normal Power

12 AWG

CAT5/6 Cable

Photo Sensor

NXDS

(As required)(As required)

NX Bridge Module

NXHNB2

G

V1

H1

N

Red

White

Violet

Gray

18 AWG

4x4 JUNCTION

BOX

BA

Blu

e

Blu

e

Remote Test Button or

Fire Alarm interface

NXRC-UL924-UNV

Normal / Emergency Power

12 AWG

Normal/Emergency

Dimming Load

HubbNET NetworkHubbNET Network

CAT5/6 Cable

CAT5/6 CableCAT5/6 Cable

R

HUBBELL

Building

Automation

+

-

OC

C

PC

RJ45 Adapter

Red 24V

DC

Blue

Black

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

Low Voltage

Occupancy Sensor

Typical Model : OMDT2

CAT5/6 Cable

18 AWG

Low Voltage Occupancy Sensor

Select model of sensor based on

application and requirement.

Additional sensors can be added in the

daisy chain up to 'X' nos. observing

power budget of controller.

Please refer to notes section in this

document

(As required)

Black (Line 120/277/347 V

AC

)

White (N

eutral)

12 AWG

Violet/Striped

Cap Off

CAT5/6 Cable

DRAWN BY: DATE:

DRAWING / DESIGN NO.:

SCALE:REV.

TITLE:

08/04/2020SR

0NTS

701 Millennium Blvd.

Greenville, SC 29607

www.hubbellcontrolsolutions.com

NX TYPICAL CONFIGURATIONS:

NXRC CONTROLLERS WITH DUAL LOAD

HCS - NX - S6

Main Switchboard: (864) 678-1000

Technical Service: (800) 888-8006

Date

By

Rev.

05/20/21 AJB