24
OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER ® Save this manual for future reference. RP30D CGP20 CGP20L This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product is permitted after the manufactured (mobile) home is sited) This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in- structions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a quali- fied installer, service agency, or the gas supplier. WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For as- sistance or additional information consult a qualified installer, ser- vice agency, or the gas supplier. WARNING: This is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation sec- tion on page 3 of this manual.

BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

  • Upload
    vutu

  • View
    223

  • Download
    2

Embed Size (px)

Citation preview

Page 1: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

OWNER’S OPERATION AND INSTALLATION MANUAL

MODELS: CGP20, CGP20L, AND RP30D

BLUE-FLAME VENT-FREEPROPANE/LP GAS HEATER

®

Save this manual for future reference.

RP30DCGP20

CGP20L

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibitedby state or local codes.*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product ispermitted after the manufactured (mobile) home is sited)This appliance is only for use with the type of gas indicated on the rating plate.This appliance is not convertible for use with other gases.

WARNING: If the information in this manual is not fol-lowed exactly, a fire or explosion may result causingproperty damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammablevapors and liquids in the vicinity of this or any otherappliance.— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.• Do not touch any electrical switch; do not use any

phone in your building.• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s in-structions.

• If you cannot reach your gas supplier, call the firedepartment.

— Installation and service must be performed by a quali-fied installer, service agency, or the gas supplier.

WARNING: Improper installation,adjustment, alteration, service, ormaintenance can cause injury orproperty damage. Refer to thismanual for correct installation andoperational procedures. For as-sistance or additional informationconsult a qualified installer, ser-vice agency, or the gas supplier.

WARNING: This is an unventedgas-fired heater. It uses air (oxy-gen) from the room in which it isinstalled. Provisions for adequatecombustion and ventilation airmust be provided. Refer to Air forCombustion and Ventilation sec-tion on page 3 of this manual.

Page 2: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

2 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

PRODUCTFEATURESSafety Device

This heater has a pilot with an OxygenDepletion Sensor Shutoff System (ODS).The ODS/pilot is a required feature for vent-free heaters. The ODS/pilot shuts off theheater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This systemrequires no matches, batteries, or othersources to light heater.

UNPACKING1. Remove heater from carton.

2. Remove all protective packaging ap-plied to heater for shipment.

3. Check heater for any shipping damage.If heater is damaged, promptly informdealer where you bought heater.

LOCAL CODESInstall and use heater with care. Follow alllocal codes. In the absence of local codes,use the latest edition of National Fuel GasCode ANSI Z223.1, also known as NFPA54*.

*Available from:

American National Standards Institute, Inc.1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.Batterymarch ParkQuincy, MA 02269

Carbon Monoxide Poisoning : Earlysigns of carbon monoxide poisoning re-semble the flu, with headaches, dizziness,or nausea. If you have these signs, the heatermay not be working properly. Get fresh airat once! Have heater serviced. Some peopleare more affected by carbon monoxide thanothers. These include pregnant women, per-sons with heart or lung disease or anemia,those under the influence of alcohol, andthose at high altitudes.

Propane/LP Gas: Propane/LP gas is odor-less. An odor-making agent is added topropane/LP gas. The odor helps you detecta propane/LP gas leak. However, the odoradded to propane/LP gas can fade. Propane/LP gas may be present even though no odorexists.

Make certain you read and understand allWarnings. Keep this manual for reference.It is your guide to safe and proper operationof this heater.

SAFETYINFORMATION

1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases.

IMPORTANT: Read this Owner’sManual carefully and completelybefore trying to assemble, oper-ate, or service this heater. Im-proper use of this heater cancause serious injury or deathfrom burns, fire, explosion, elec-trical shock, and carbon monox-ide poisoning.

WARNING ICON G 001 WARNINGS

DANGER: Carbon monoxidepoisoning may lead to death!

WARNING: Any change to thisheater or its controls can be dan-gerous.

2. Do not place propane/LP supply tank(s)inside any structure. Locate propane/LP supply tank(s) outdoors.

3. This heater shall not be installed in abedroom or bathroom.

4. If you smell gas• shut off gas supply• do not try to light any appliance• do not touch any electrical switch;

do not use any phone in your building• immediately call your gas supplier

from a neighbor’s phone. Follow thegas supplier’s instructions

• if you cannot reach your gas supplier,call the fire department

5. Never install the heater• in a recreational vehicle• where curtains, furniture, clothing, or

other flammable objects are less than36 inches from the front, top, or sidesof the heater

• as a fireplace insert• in high traffic areas• in windy or drafty areas

6. This heater needs fresh, outside air ven-tilation to run properly. This heater hasan oxygen depletion sensor (ODS) pi-lot light safety system. The ODS shutsdown the heater if not enough fresh airis available. See Air for Combustionand Ventilation, pages 3 through 5.

7. Keep all air openings in the front andbottom of heater clear and free of de-bris. This will insure enough air forproper combustion.

8. If heater shuts off, do not relight untilyou provide fresh, outside air. If heaterkeeps shutting off, have it serviced.

9. Do not run heater• where flammable liquids or vapors

are used or stored• under dusty conditions

10. Never place any objects on the heater.

11. Surface of heater becomes very hotwhen running heater. Keep children andadults away from hot surface to avoidburns and clothing ignition. Heater willremain hot for a time after shutdown.Allow surface to cool before touching.

12. Make sure grill guard is in place be-fore running heater.

13. Carefully supervise young childrenwhen they are in same room withheater.

14. Do not use heater if any part has beenunder water. Immediately call a quali-fied service technician to inspect theroom heater and to replace any part ofthe control system and any gas controlwhich has been under water.

15. Turn off heater and let cool before ser-vicing. Only a qualified service personshould service and repair heater.

16. Operating heater above elevations of4,500 feet could cause pilot outage.

17. To prevent performance problems, donot use propane fuel tank of less thanthan 100 lbs. capacity.

Page 3: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

3103569

OWNER’S MANUAL

PRODUCTIDENTIFICATION

Figure 1 - Vent-Free Propane/LP Gas Heater

Ignitor Button Control Knob

HeaterCabinet

FrontPanel

Heat Shield(RP30D) orGlass Panel(CGP20[L])

GrillGuard

AIR FORCOMBUSTION ANDVENTILATION

Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home own-ers weather strip and caulk around windowsand doors to keep the cold air out and thewarm air in. During heating months, homeowners want their homes as airtight as pos-sible.

PROVIDING ADEQUATEVENTILATIONThe following is excerpts from NationalFuel Gas Code. NFPA 54/ANSI Z223.1,Section 5.3, Air for Combustion and Venti-lation.

All spaces in homes fall into one of the threefollowing ventilation classifications:

1. Unusually Tight Construction; 2. Uncon-fined Space; 3. Confined Space.

The information on pages 3 through 5 willhelp you classify your space and provideadequate ventilation.

Confined and Unconfined Space

The National Fuel Gas Code (ANSIZ2123.1,1992 Section 5.3) defines a confined spaceas a space whose volume is less than 50cubic feet per 1,000 Btu per hour (4.8 m3 perkw) of the aggregate input rating of allappliances installed in that space and anunconfining space as a space whose volumeis not less than 50 cubic feet per 1,000 Btuper hour (4.8 m3 per kw) of the aggregateinput rating of all appliances installed in thatspace. Rooms communicating directly withthe space in which the appliances are in-stalled*, through openings not furnishedwith doors, are considered a part of theunconfined space.

* Adjoining rooms are communicating onlyif there are doorless passageways or ventila-tion grills between them.

WARNING: This heater shallnot be installed in a confinedspace unless provisions are pro-vided for adequate combustionand ventilation air. Read the fol-lowing instructions to insureproper fresh air for this and otherfuel-burning appliances in yourhome.

While it is good to make your home energyefficient, your home needs to breathe. Freshair must enter your home. All fuel-burningappliances need fresh air for proper com-bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, andfuel burning appliances draw air from thehouse to operate. You must provide ad-equate fresh air for these appliances. Thiswill insure proper venting of vented fuel-burning appliances.

Unusually Tight Construction

The air that leaks around doors and win-dows may provide enough fresh air forcombustion and ventilation. However, inbuildings of unusually tight construction,you must provide additional fresh air.

Unusually tight construction is de-fined as construction where:a. walls and ceilings exposed to the

outside atmosphere have a con-tinuous water vapor retarder witha rating of one perm (6x10 -11 kgper pa-sec-m 2) or less with open-ings gasketed or sealed and

b. weather stripping has beenadded on openable windows anddoors and

c. caulking or sealants are appliedto areas such as joints aroundwindow and door frames, be-tween sole plates and floors, be-tween wall-ceiling joints, be-tween wall panels, at penetra-tions for plumbing, electrical, andgas lines, and at other openings.

If your home meets all of the threecriteria above, you must provide ad-ditional fresh air. See Ventilation AirFrom Outdoors , page 5 .

If your home does not meet all of thethree criteria above, proceed to page 4.

Continued

Page 4: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

4 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

Continued

WARNING: If the area inwhich the heater may be oper-ated is smaller than that definedas an unconfined space, provideadequate combustion and venti-lation air by one of the methodsdescribed in the National FuelGas Code, ANSI Z223.1, 1992,Section 5.3 or applicable localcodes.

WARNING: Rework work-sheet, adding the space of theadjoining unconfined space. Thecombined spaces must haveenough fresh air to supply allappliances in both spaces.

AIR FORCOMBUSTION ANDVENTILATIONContinued

DETERMINING AIR FLOWFOR HEATER LOCATION

Determining if You Have aConfined or Unconfined Space

Use this worksheet to determine if you havea confined or unconfined space.

Space: Includes the room in which youwill install heater plus any adjoining roomswith doorless passageways or ventilationgrills between the rooms.

1. Determine the volume of the space(length x width x height).

Length x Width x Height =___________cu. ft. (volume of space)

Example: Space size 20 ft. (length) x16 ft. (width) x 8 ft. (ceiling height) =

2560 cu. ft. (volume of space)

If additional ventilation to adjoiningroom is supplied with grills or open-ings, add the volume of these rooms tothe total volume of the space.

2. Divide the space volume by 50 cubicfeet to determine the maximum Btu/Hrthe space can support.

______(volume of space) ÷ 50 cu. ft. =(Maximum Btu/Hr the space can sup-port)

Example: 2560 cu. ft. (volume ofspace) ÷ 50 cu. ft. = 51.2 or 51,200(maximum Btu/Hr the space can sup-port)

3. Add the Btu/Hr of all fuel burning ap-pliances in the space.

Vent-free heater _________ Btu/Hr

Gas water heater*________ Btu/Hr

Gas furnace ____________ Btu/Hr

Vented gas heater ________ Btu/Hr

Gas fireplace logs ________ Btu/Hr

Other gas appliances*+____ Btu/Hr

Total = ____Btu/Hr

Example:Gas water heater 40,000 Btu/Hr

Vent-free heater + 20,000 Btu/Hr

Total = 60,000 Btu/Hr

* Do not include direct-vent gas appli-ances. Direct-vent draws combustionair from the outdoors and vents to theoutdoors.

4. Compare the maximum Btu/Hr thespace can support with the actualamount of Btu/Hr used.

__________ Btu/Hr (maximum thespace can support)

___________ Btu/Hr (actual amount ofBtu/Hr used)

Example: 51,200 Btu/Hr (maximumthe space can support)

60,000 Btu/Hr (actual amount ofBtu/Hr used)

The space in the above example is a con-fined space because the actual Btu/Hr usedis more than the maximum Btu/Hr the spacecan support. You must provide additionalfresh air. Your options are as follows:

A. Rework worksheet, adding the space ofan adjoining room. If the extra spaceprovides an unconfined space, removedoor to adjoining room or add ventila-tion grills between rooms. See Ventila-tion Air From Inside Building.

B. Vent room directly to the outdoors. SeeVentilation Air From Outdoors, page 5.

C. Install a lower Btu/Hr heater, if lowerBtu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than themaximum Btu/Hr the space can support, thespace is an unconfined space. You will needno additional fresh air ventilation.

VENTILATION AIR

Ventilation Air From InsideBuilding

This fresh air would come from an adjoiningunconfined space. When ventilating to anadjoining unconfined space, you must pro-vide two permanent openings: one within12" of the ceiling and one within 12" of thefloor on the wall connecting the two spaces(see options 1 and 2, Figure 2 page 5). Youcan also remove door into adjoining room(see option 3, Figure 2). Follow the NationalFuel Gas Code NFPA 54/ANSI Z223.1, Sec-tion 5.3, Air for Combustion and Ventilationfor required size of ventilation grills orducts.

Page 5: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

5103569

OWNER’S MANUAL

Figure 2 - Ventilation Air from Inside Building

Or Remove Door into Adjoining

Room, Option 3

Ventilation Grills Into Adjoining Room,

Option 2

12"

12"

VentilationGrills

into AdjoiningRoom,

Option 1

AIR FOR COMBUSTIONAND VENTILATIONContinued

OutletAir

VentilatedAttic

OutletAir

InletAir

Inlet Air Ventilated Crawl Space

To CrawlSpace

To Attic

Figure 3 - Ventilation Air from Outdoors

Ventilation Air From Outdoors

Provide extra fresh air by using ventilationgrills or ducts. You must provide two per-manent openings: one within 12" of theceiling and one within 12" of the floor.Connect these items directly to the outdoorsor spaces open to the outdoors. These spacesinclude attics and crawl spaces. Follow theNational Fuel Gas Code NFPA 54/ANSIZ223.1, Section 5.3, Air for Combustion andVentilation for required size of ventilationgrills or ducts.

IMPORTANT: Do not provide openingsfor inlet or outlet air into attic if attic has athermostat-controlled power vent. Heatedair entering the attic will activate the powervent.

Page 6: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

6 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

CAUTION: If you install theheater in a home garage• heater pilot and burner must

be at least 18 inches abovefloor

• locate heater where movingvehicle will not hit it

For convenience and efficiency, install heater

• where there is easy access for operation,inspection, and service

• where strong wind gusts from an opendoor or garage door can not blow directlyinto heater.

An optional fan kit is available from yourdealer. See Accessories, page 17. If plan-ning to use fan, locate heater near an electri-cal outlet.

36"

*FLOOR

CEILING

Minimum

Minimum To Floor

6"MinimumFromSides OfHeater

LeftSide

RightSide

*163/4" - RP30D*3" - CGP20(L)

Figure 4 - Mounting Clearances As Viewed From Front of Heater

INSTALLING TOWALL

NOTICE: A qualified service per-son must install heater. Followall local codes.

CHECK GAS TYPEUse only propane/LP gas. If your gas supplyis not propane/LP, do not install heater. Calldealer where you bought heater for propertype heater.

INSTALLATION ITEMSBefore installing heater, make sure you havethe items listed below.

• external regulator (supplied by installer,see page 8)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• manual shutoff valve *

• ground joint union

• test gauge connection * (see Figure 13,page 9)

• sediment trap

• tee joint

• pipe wrench

* An A.G.A. design certified manual shutoffvalve with 1/8" NPT tap is an acceptablealternative to test gauge connection. Pur-chase the optional A.G.A. design certi-fied manual shutoff valve from yourdealer. See Accessories, page 17.

LOCATING HEATERThis heater is designed to be mounted on awall.

Continued

WARNING: Maintain the mini-mum clearances shown in Figure4. If you can, provide greater clear-ances from floor, ceiling, and join-ing wall.

You can locate model CGP20 and CGP20Lon floor, away from a wall. An optionalfloor mounting stand is needed. Purchasethe floor mounting stand from your dealer.See Accessories, page 17.

WARNING: Never install theheater• in a bedroom or bathroom• in a recreational vehicle• where curtains, furniture,

clothing, or other flammableobjects are less than 36 inchesfrom the front, top, or sides ofthe heater

• as a fireplace insert• in high traffic areas• in windy or drafty areas

CAUTION: This heater cre-ates warm air currents. These cur-rents move heat to wall surfacesnext to heater. Installing heaternext to vinyl or cloth wall cover-ings or operating heater whereimpurities in the air (such as to-bacco smoke) exist, may discolorwalls.

IMPORTANT: Vent-free heaters add mois-ture to the air. Although this is beneficial,installing heater in rooms without enoughventilation air may cause mildew to formfrom too much moisture. See Air for Com-bustion and Ventilation, pages 3 through 5.

Page 7: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

7103569

OWNER’S MANUAL

INSTALLING HEATER TOWALL

Mounting Bracket

The mounting bracket is located on backpanel of heater. It has been taped there forshipping. Remove mounting bracket fromback panel.

Figure 5 - Mounting Bracket Location

Removing Front Panel Of Heater1. Remove two screws near bottom cor-

ners of front panel.

2. Lift straight up on grill guard until itstops. Grill guard will slide up about1/4".

3. Pull bottom of front panel forward, thendown.

4. Remove cardboard packing from grilland glass (CGP20[L]) or heat shield(RP30D).

Figure 6 - Removing Front Panel Of Heater

Continued

INSTALLING TOWALLContinued

MountingBracket

Methods For AttachingMounting Bracket To Wall

Only use last hole on each end of mountingbracket to attach bracket to wall. These twoholes are 16 inches apart from their centers.Attach mounting bracket to wall in one oftwo ways.

1. Attaching to wall stud

2. Attaching to wall anchor

Marking Screw Locations1. Tape mounting bracket to wall where

heater will be located. Make suremounting bracket is level.

2. Mark screw locations on wall (see Fig-ure 7).

WARNING: Maintain minimumclearances shown in Figure 7. Ifyou can, provide greater clear-ances from floor and joining wall.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1. Drill holes at marked locations using9/64" drill bit.

2. Place mounting bracket onto wall. Lineup last hole on each end of bracket withholes drilled in wall.

3. Insert mounting screws through bracketand into wall studs.

4. Tighten screws until mounting bracketis firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollowwalls (wall areas between studs) or solidwalls (concrete or masonry)

1. Drill holes at marked locations using5/16" drill bit. For solid walls (concreteor masonry), drill at least 1" deep.

2. Fold wall anchor as shown in Figure 8.

16"

18 3/4"Min.

7 1/4"Min.

Adj

oini

ng W

all

Only Insert Mounting Screws Through Last

Hole On Each End

Floor

Note: Only mark last hole on each endof mounting bracket. Insert mountingscrews through these holes only.

3. Remove tape and mounting bracketfrom wall.

Attaching to wall stud: This methodprovides the strongest hold. Insert mountingscrews through mounting bracket and intowall studs.

Attaching to wall anchor: This methodallows you to attach mounting bracket tohollow walls (wall areas between studs) orto solid walls (concrete or masonry).

Decide which method better suits your needs.Either method will provide a secure hold forthe mounting bracket.

Figure 8 - Folding Anchor

Figure 7 - Mounting Bracket Clearances

3. Insert wall anchor (wings first) intohole. Tap anchor flush to wall.

4. For thin walls (1/2" or less), insert redkey into wall anchor. Push red key to“pop” open anchor wings.

MPORTANT: Do not hammer key!

For thick walls (over 1/2" thick) or solidwalls, do not pop open wings.

CGP20(L)

32 1/2"Min.

11"Min.

16"

Adj

oini

ng W

all

Only Insert Mounting Screws Through Last

Hole On Each End

Floor

RP30D

Figure 9 - Popping Open Anchor WingsFor Thin Walls

5. Place mounting bracket onto wall. Lineup last hole on each end of bracket withwall anchors.

6. Insert mounting screws through bracketand into wall anchors.

7. Tighten screws until mounting bracketis firmly fastened to wall.

Attaching Mounting Bracket ToWallNote: Wall anchors, mounting screws, andspacers are in hardware package. The hard-ware package is provided with heater.

Page 8: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

8 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

Continued

CONNECTING TOGAS SUPPLY

The installer must supply an external regu-lator. The external regulator will reduceincoming gas pressure. You must reduceincoming gas pressure to between 11 and 14inches of water. If you do not reduce incom-ing gas pressure, heater regulator damagecould occur. Install external regulator withthe vent pointing down as shown in Figure12. Pointing the vent down protects it fromfreezing rain or sleet.

NOTICE: A qualified service per-son must connect heater to gassupply. Follow all local codes.

CAUTION: Never connectheater directly to the propane/LPsupply. This heater requires anexternal regulator (not supplied).Install the external regulator be-tween the heater and propane/LPsupply.

CAUTION: Use only new,black iron or steel pipe. Inter-nally-tinned copper tubing maybe used in certain areas. Checkyour local codes. Use pipe of 1/2"diameter or greater to allowproper gas volume to heater. Ifpipe is too small, undue loss ofpressure will occur.

Install sediment trap in supply line as shownin Figure 13, page 9. Locate sediment trapwhere it is within reach for cleaning. Locatesediment trap where trapped matter is notlikely to freeze. A sediment trap traps mois-ture and contaminants. This keeps themfrom going into heater controls. If sedimenttrap is not installed or is installed wrong,heater may not run properly.

CAUTION: Use pipe joint seal-ant that is resistant to liquid pe-troleum (LP) gas.

Installation must include a manual shutoffvalve, union, and plugged 1/8" NPT tap.Locate NPT tap within reach for test gaugehook up. NPT tap must be upstream fromheater (see Figure 13, page 9).

Apply pipe joint sealant lightly to malethreads. This will prevent excess sealantfrom going into pipe. Excess sealant in pipecould result in clogged heater valves.

Typical Inlet Pipe Diameters

20,000 Btu/Hr models 3/8" or greater

30,000 Btu/Hr models 1/2" or greater

Placing Heater On MountingBracket1. Locate two horizontal slots on back

panel of heater.

2. Place heater onto mounting bracket.Slide horizontal slots onto stand-outtabs on mounting bracket.

Installing Bottom MountingScrews1. Locate two bottom mounting holes.

These holes are near bottom on backpanel of heater (see Figure 11).

Figure 10 - Mounting Heater OntoMounting Bracket

2. Mark screw locations on wall.

3. Remove heater from mounting bracket.

4. If installing bottom mounting screwsinto hollow or solid wall, install wallanchors. Follow steps 1 through 4 un-der Attaching To Wall Anchor Method,page 7.

If installing bottom mounting screwinto wall stud, drill holes at marked lo-cations using 9/64" drill bit.

5. Replace heater onto mounting bracket.

6. Place spacers between bottom mount-ing holes and wall anchor or drilledhole.

Figure 11 - Installing Bottom MountingScrews

INSTALLING TOWALLContinued

Stand-Out TabMounting Bracket(attached to wall)

HorizontalSlots

7. Hold spacer in place with one hand.With other hand, insert mounting screwthrough bottom mounting hole andspacer. Place tip of screw in openingof wall anchor or drilled hole.

8. Tighten both screws until heater isfirmly secured to wall. Do not overtighten.

Note: Do not replace front panel at thistime. Replace front panel after makinggas connections and checking for leaks(see pages 8-9).

Propane/LPSupply Tank

VentPointingDown

ExternalRegulator

Figure 12 - External Regulator with VentPointing Down

Page 9: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

9103569

OWNER’S MANUAL

Figure 13 - Gas Connection

* An A.G.A. design certified manual shutoffvalve with 1/8" NPT tap is an acceptablealternative to test gauge connection. Pur-chase the optional A.G.A. design certifiedmanual shutoff valve from your dealer. SeeAccessories, page 17.

IMPORTANT: Hold pressure regulatorwith wrench when connecting it to gas pip-ing and/or fittings.

CONNECTING TOGAS SUPPLYContinued

Tee Joint

ReducerBushing to 1/8"NPT

1/8" NPT PlugTap

TestGaugeConnection *

Tee Joint

Pipe Nipple

Cap

HeaterCabinet

PressureRegulator

3/8" NPTPipeNipple

Ground JointUnion

ManualShutoffValve *

Typical InletPipe FromExternal Regulator(11" W.C. to 14"W.C. Pressure)

3" MinimumSedimentTrap

CHECKING GASCONNECTIONS

WARNING: Test all gas pip-ing and connections for leaksafter installing or servicing. Cor-rect all leaks at once.

WARNING: Never use an openflame to check for a leak. Apply amixture of liquid soap and waterto all joints. Bubbles formingshow a leak. Correct all leaks atonce.

CAUTION: Make sure exter-nal regulator has been installedbetween propane/LP supply andheater. See guidelines under Con-necting to Gas Supply .

PRESSURE TESTING GASSUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2PSIG1. Disconnect heater and its individual

manual shutoff valve from gas supplypiping system. Pressures in excess of1/2 PSIG will damage heater regulator.

2. Cap off open end of gas pipe wheremanual shutoff valve was connected.

3. Pressurize supply piping system by ei-ther using compressed air or

opening propane/LP supply tank valve.

4. Check all joints of gas supply pipingsystem. Apply mixture of liquid soapand water to gas joints. Bubbles form-ing show a leak.

5. Correct all leaks at once.

Test Pressures Equal To orLess Than 1/2 PSIG1. Close manual shutoff valve (see Fig-

ure 14).

Figure 14 - Manual Shutoff Valve

2. Pressurize supply piping system by ei-ther using compressed air or openingpropane/LP supply tank valve.

ONPOSITION

OFFPOSITION

ManualShutoffValve

Closed

Open

Note: Burner bracketnot shown for clarity

3. Check all joints from propane/LP sup-ply tank to manual shutoff valve (seeFigure 15, page 10). Apply mixture ofliquid soap and water to gas joints.Bubbles forming show a leak.

4. Correct all leaks at once.

PRESSURE TESTINGHEATER GASCONNECTIONS1. Open manual shutoff valve (see Fig-

ure 14).

2. Open propane/LP supply tank valve.

3. Make sure control knob of heater is inthe OFF position.

4. Check all joints from manual shutoffvalve to control valve (see Figure 15,page 10). Apply mixture of liquid soapand water to gas joints. Bubbles form-ing show a leak.

5. Correct all leaks at once.

6. Light heater (see Operating Heater,pages 10 and 11). Check the rest of theinternal joints for leaks.

7. Turn off heater (see To Turn Off Gas toAppliance, page 11).

8. Replace front panel. Continued

Page 10: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

10 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

4. Wait five (5) minutes to clear out anygas. Then smell for gas, includingnear the floor. If you smell gas,STOP! Follow “B” in the safety in-formation in the first column. If youdon’t smell gas, go to the next step.

5. Press in control knob and turn coun-terclockwise to the PILOTposition. Keep control knob pressedin for five (5) seconds (see Figure 16).Note: You may be running thisheater for the first time after hook-ing up to gas supply. If so, the con-trol knob may need to be pressed infor 30 seconds. This will allow air tobleed from the gas system.• If control knob does not pop up

when released, contact a qualifiedservice person or gas supplier forrepairs.

6. With control knob pressed in, pushdown and release ignitor button. Thiswill light pilot. The pilot is attachedto the front of burner. The burnerand pilot are located behind the heatshield. If needed, keep pressing igni-tor button until pilot lights.Note: If pilot does not stay lit, referto Troubleshooting, pages 12 through14. Also contact a qualified serviceperson or gas supplier for repairs.Until repairs are made, light pilotwith match. To light pilot with match,see Manual Lighting Procedure,page 11.

Figure 17 - Pilot

7. Keep control knob pressed in for 30seconds after lighting pilot. After 30seconds, release control knob.Note : If pilot goes out, repeat steps3 through 7.

OPERATINGHEATER

FOR YOUR SAFETYREAD BEFORE

LIGHTING

A. This appliance has a pilot which mustbe lighted by hand. When lighting thepilot, follow these instructions ex-actly.

B. BEFORE LIGHTING smell allaround the appliance area for gas. Besure to smell next to the floor becausesome gas is heavier than air and willsettle on the floor.WHAT TO DO IF YOU SMELLGAS• Do not try to light any appliance.• Do not touch any electric switch;

do not use any phone in your building.• Immediately call your gas supplier

from a neighbor’s phone. Followthe gas supplier’s instructions.

• If you cannot reach your gas sup-plier, call the fire department.

LIGHTINGINSTRUCTIONS

1. STOP! Read the safety informationabove.

2. Make sure manual shutoff valve isfully open.

3. Turn control knob clockwise Clockwise

to the OFF position.

Figure 16 - Control Knob In The OFFPosition

WARNING: If you do not fol-low these instructions exactly, afire or explosion may result caus-ing property damage, personalinjury or loss of life.

Continued

CHECKING GASCONNECTIONSContinued

Figure 15 - Checking Gas Joints

Propane/LPSupply Tank

Control Valve Location

ManualShutoffValve

C. Use only your hand to push in or turnthe gas control knob. Never use tools.If the knob will not push in or turnby hand, don’t try to repair it, call aqualified service technician or gassupplier. Force or attempted repairmay result in a fire or explosion.

D. Do not use this appliance if any parthas been under water. Immediatelycall a qualified service technician toinspect the appliance and to replaceany part of the control system andany gas control which has been un-der water.

OFF

HIGH

PILOTLOW

IGNITOR

Ignitor Button Control Knob Pilot GRH/OV 007G

ThermocouplePilot Burner

Ignitor Electrode

Page 11: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

11103569

OWNER’S MANUAL

1/2 HEAT SHIELD OR GLASS HEIGHT

INCORRECT FLAME PATTERNAT HIGH POSITION

OPERATINGHEATERContinued

CAUTION: Do not try to ad-just heating levels by using themanual shutoff valve.

8. Turn control knob counterclockwise to the LOW position. The

main burner should light. Set controlknob to any heat level betweenHIGH and LOW. To turn controlknob from LOW to a higher setting,press in the control knob and turncounterclockwise .Note : Both HIGH and LOW arelocked positions. You must press incontrol knob before turning it fromthese positions.

TO TURN OFF GASTO APPLIANCE

Shutting Off Heater1. Turn control knob clockwise

to the PILOT position.2. Press in control knob and turn clock-

wise to the OFF position.3. Turn off all electric power to the ap-

pliance if service is to be performed.

Shutting Off Burner Only (pilotstays lit)1. Turn control knob clockwise

to the PILOT position.

MANUAL LIGHTINGPROCEDURE

1. Remove front panel (see Figure 6,page 7).

2. Follow steps 1 through 5 under Light-ing Instructions, page 10.

3. With control knob pressed in, strikematch. Hold match to pilot until pi-lot lights.

4. Keep control knob pressed in for 30seconds after lighting pilot. After 30seconds, release control knob.

5. Replace front panel.

INSPECTINGBURNERCheck pilot flame pattern and burner flamepattern often.

PILOT FLAME PATTERNFigure 18 shows a correct pilot flame pat-tern. Figure 19 shows an incorrect pilotflame pattern. The incorrect pilot flame isnot touching the thermocouple. This willcause the thermocouple to cool. When thethermocouple cools, the heater will shutdown.

Figure 18 - Correct Pilot Flame Pattern

Figure 19 - Incorrect Pilot Flame Pattern

NOTICE: Do not mistake orangeflames with yellow tipping. Dirtor other fine particles enter theheater and burn causing briefpatches of orange flame.

ThermocouplePilot Burner

Pilot BurnerThermocouple

Figure 20 - Correct Burner Flame Pattern

Figure 21 - Incorrect Burner Flame Pattern

If pilot flame pattern is incorrect, as shownin Figure 19

• turn heater off (see To Turn Off Gas toAppliance,)

• see Troubleshooting, pages 12 through 14

BURNER FLAME PATTERNFigure 20 shows a correct burner flamepattern. Figure 21 shows an incorrect burnerflame pattern. The incorrect burner flamepattern shows yellow tipping of the flame. Italso shows the flame higher than 1/2 theheat shield height.

WARNING: If yellow tippingoccurs, your heater could pro-duce increased levels of carbonmonoxide. If burner flame pat-tern shows yellow tipping, followinstructions at bottom of thispage.

YellowTipping

CORRECT FLAME PATTERNAT HIGH POSITION

1/2 HEAT SHIELD OR GLASS HEIGHT

If burner flame pattern is incorrect, as shownin Figure 21

• turn heater off (see To Turn Off Gas toAppliance

• see Troubleshooting, pages 12 through 14

Page 12: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

12 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

TROUBLESHOOTINGNote: All troubleshooting items are listedin order of operation.

WARNING: Turn off andunplug heater and let cool be-fore servicing. Only a qualifiedservice person should serviceand repair heater.

CAUTION: Never use a wire,needle, or similar object to cleanODS/pilot. This can damage ODS/pilot unit.

OBSERVED PROBLEM

When ignitor button is pressed, there is nospark at ODS/pilot

When ignitor button is pressed, there isspark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out whencontrol knob is released

Burner does not light after ODS/pilot is lit

POSSIBLE CAUSE

1. Ignitor electrode positioned wrong2. Ignitor electrode broken3. Ignitor electrode not connected to igni-

tor cable4. Ignitor cable pinched or wet

5. Broken ignitor cable6. Bad piezo ignitor

1. Gas supply turned off or manual shutoffvalve closed

2. Control knob not in PILOT position3. Control knob not pressed in while in

PILOT position4. Air in gas lines when installed

5. Depleted gas supply6. ODS/pilot is clogged

7. Gas regulator setting is not correct

1. Control knob not fully pressed in2. Control knob not pressed in long enough

3. Manual shutoff valve not fully open4. Thermocouple connection loose at con-

trol valve5. Pilot flame not touching thermocouple,

which allows thermocouple to cool,causing pilot flame to go out. Thisproblem could be caused by one or bothof the following:A) Low gas pressureB) Dirty or partially clogged ODS/

pilot6. Thermocouple damaged7. Control valve damaged

1. Burner orifice is clogged

2. Burner orifice diameter is too small3. Inlet gas pressure is too low

REMEDY

1. Replace ignitor2. Replace ignitor3. Reconnect ignitor cable

4. Free ignitor cable if pinched by anymetal or tubing. Keep ignitor cable dry

5. Replace ignitor cable6. Replace piezo ignitor

1. Turn on gas supply or open manualshutoff valve

2. Turn control knob to PILOT position3. Press in control knob while in PILOT

position4. Continue holding down control knob.

Repeat igniting operation until air isremoved

5. Contact local propane/LP gas company6. Clean ODS/pilot (see Cleaning and

Maintenance, page 15) or replace ODS/pilot assembly

7. Replace gas regulator

1. Press in control knob fully2. After ODS/pilot lights, keep control

knob pressed in 30 seconds3. Fully open manual shut-off valve4. Hand tighten until snug, then tighten 1/

4 turn more5. A) Contact local propane/LP gas com-

pany

B) Clean ODS/pilot (see Cleaning andMaintenance, page 15) or replace ODS/pilot assembly

6. Replace thermocouple7. Replace control valve

1. Clean burner (see Cleaning and Main-tenance, page 15) or replace burnerorifice

2. Replace burner orifice3. Contact local propane/LP gas company

Continued

Page 13: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

13103569

OWNER’S MANUAL

TROUBLESHOOTINGContinued

OBSERVED PROBLEM

Delayed ignition of burner

Burner backfiring during combustion

Yellow flame during burner combustion

Slight smoke or odor during initial opera-tion

Heater produces a whistling noise whenburner is lit

POSSIBLE CAUSE

1. Manifold pressure is too low2. Burner orifice is clogged

1. Burner orifice is clogged or damaged

2. Inlet gas pressure is too low3. Burner damaged4. Gas regulator defective

1. Not enough air

2. Inlet gas pressure is too low3. Gas regulator defective

1. Residues from manufacturing processes

1. Turning control knob to HIGH positionwhen burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner ori-fice

Continued

REMEDY

1. Contact local propane/LP gas company2. Clean burner (see Cleaning and Main-

tenance, page 15) or replace burnerorifice

1. Clean burner (see Cleaning and Main-tenance, page 15) or replace burnerorifice

2. Contact local propane/LP gas company3. Replace burner4. Replace gas regulator

1. Check burner for dirt and debris. Iffound, clean burner (see Cleaning andMaintenance, page 15)

2. Contact local propane/LP gas company3. Replace gas regulator

1. Problem will stop after a few hours ofoperation

1. Turn control knob to LOW positionand let warm up for a minute

2. Operate burner until air is removedfrom line. Have gas line checked bylocal propane/LP gas company

3. Observe minimum installation clear-ances (see Figure 4, page 6)

4. Clean burner (see Cleaning and Main-tenance, page 15) or replace burnerorifice

Page 14: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

14 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

TROUBLESHOOTINGContinued

WARNING ICON G 001

WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your

building.• Immediately call your gas supplier from a neighbor’s phone. Follow

the gas supplier’s instructions.• If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaningsupplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,etc., create fumes. These fumes may mix with combustion air and create odors.

POSSIBLE CAUSE

1. Metal expanding while heating or con-tracting while cooling

1. Heater burning vapors from paint, sol-vents, glues, etc. See IMPORTANTstatement above

2. Low fuel supply3. Gas leak. See Warning statement

at top of page

1. Not enough fresh air is available2. Low line pressure3. ODS/pilot is partially clogged

1. Gas leak. See Warning statementat top of page

2. Control valve defective

1. Foreign matter between control valveand burner

2. Gas leak. See Warning statementat top of page

1. Not enough combustion/ventilation air.

OBSERVED PROBLEM

Heater produces a clicking/ticking noisejust after burner is lit or shut off

Heater produces unwanted odors

Heater shuts off in use (ODS operates)

Gas odor even when control knob is in OFFposition

Gas odor during combustion

Moisture/condensation noticed on windows

REMEDY

1. This is common with most heaters. Ifnoise is excessive, contact qualifiedservice person

1. Ventilate room. Stop using odor caus-ing products while heater is running

2. Refill supply tank3. Locate and correct all leaks (see Check-

ing Gas Connections, pages 9 and 10)

1. Open window and/or door for ventilation2. Contact local propane/LP gas company3. Clean ODS/pilot (see Cleaning and

Maintenance, page 15)

1. Locate and correct all leaks (see Check-ing Gas Connections, pages 9 and 10)

2. Replace control valve

1. Take apart gas tubing and remove for-eign matter

2. Locate and correct all leaks (see Check-ing Gas Connections, pages 9 and 10)

1. Refer to Air for Combustion and Ven-tilation requirements (page 3)

Page 15: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

15103569

OWNER’S MANUAL

TECHNICALSERVICEYou may have further questions about in-stallation, operation, or troubleshooting. Ifso, contact DESA International’s TechnicalService Department at 1-800-323-5190.

SPECIFICATIONSRP30D CGP20(L)

Btu (Variable) 15,000/30,000 10,000/20,000

Type Gas Propane/LP Only Propane/LP Only

Ignition Piezo Piezo

Pressure Regulator Setting 8" W.C. 8" W.C.

Inlet Gas Pressure (inches of water)

Maximum 14" 14"

Minimum 11" 11"

Dimensions, Inches (H x W x D)

Heater 23.5 x 25.9 x 8.0 23.5 x 18.5 x 8.0

Carton 26 x 27.75 x 9.63 26 x 20.5 x 9.63

Weight (pounds)

Heater 30 22

Shipping 35 27

When gas pressure is too low• pilot will not stay lit

• burner will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

When gas quality is bad• pilot will not stay lit

• burner will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low orgas quality is bad. If so, contact your localpropane/LP gas supplier.

SERVICE HINTS

CLEANING ANDMAINTENANCE

WARNING: Turn off heaterand let cool before cleaning.

CAUTION: You must keepcontrol areas, burner, and circu-lating air passageways of heaterclean. Inspect these areas ofheater before each use. Haveheater inspected yearly by a quali-fied service person. Heater mayneed more frequent cleaning dueto excessive lint from carpetingand bedding material, sawdust,cobwebs, etc.

ODS/PILOT AND BURNER• Use a vacuum cleaner, pressurized air, or

small, soft bristled brush to clean.

CABINET

Air Passageways• Use a vacuum cleaner or pressurized air

to clean.

Exterior• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-net to remove dust.

Page 16: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

16 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

REPLACEMENTPARTSNote: Use only original replacement parts.This will protect your warranty coverage forparts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product.If they can’t supply original replacementpart(s), either contact your nearest PartsCentral (see below) or call DESAInternational’s Technical Service Depart-ment at 1-800-323-5190.

When calling, have ready

• your name

• your address

• model number of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or naturalgas)

• purchase date

Usually, we will ask you to return the defec-tive part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product.If they can’t supply original replacementpart(s), either contact your nearest PartsCentral (see below) or call DESAInternational’s Parts Department at 1-800-972-7879 for referral information.

When calling, have ready

• model number of your heater

• the replacement part number

PARTS CENTRALSThese Parts Centrals are privately ownedbusinesses. They have agreed to support ourcustomer’s needs by providing original re-placement parts and accessories. When call-ing a Parts Central, ask for the Parts Depart-ment.

Baltimore Electric1348 Dixwell Avenue

Hamden, CT 06514

1-800-397-7553

203-248-7553

Parts Department

Portable Heater Parts342 N. County Rd. 400 East

Valparaiso, IN 46383

All States

219-462-7441

1-800-362-6951

Parts Department

FBD1349 Adams Street

Bowling Green, KY 42103

502-846-1199

1-800-654-8534

Fax: 1-800-846-0090

Four Flags Power Products1115 Stateline Road

Niles, MI 49120

616-684-2697

1-800-268-4983

Parts Only

Master Parts Distributor1184 Wilson NW

Grand Rapids, MI 49504

US 1-800-446-1446

616-791-0505

Fax: 1-616-791-8270

Parts Department

Washer Equipment Co.1715 Main Street

Kansas City, MO 64108

KS, MO, AR

816-842-3911

Parts Department

East Coast Energy Products707 Broadway

W. Long Branch, NJ 07764

908-870-8809

1-800-755-8809

Parts Department

Tarantin Tank Co.P.O. Box 6129

Freehold, NJ 07728

908-780-9340

1-800-922-0724

Parts Department

Dayton HardwareP.O. Box 275

North Dayton Station

Dayton, OH 45404

All States

513-258-3721

OH 1-800-762-3426

Parts Department

Halco Enterprises208 Carter Drive, Unit 21

West Chester, PA 19382

610-430-7717

US 1-800-368-0803

Parts Department

Laporte's Parts & Service2444 North 5th Street

Hartsville, SC 29550

803-332-0191

Parts Department

Cans Unlimited, Inc.P.O. Box 645

Taylor, SC 29687

All States

803-879-3009

1-800-845-5301

Page 17: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

17103569

OWNER’S MANUAL

ACCESSORIESPurchase these heater accessories from yourlocal dealer. If they can not supply theseaccessories, either contact your nearest PartsCentral (see page 16) or call DESAInternational’s Parts Department at 1-800-972-7879 for referral information. You canalso write to the address listed on the backpage of this manual.

MANUAL SHUTOFFVALVE -GA5010For all models. Manual shutoff valve with1/8" NPT tap.

FLOOR MOUNTING STAND20,000 Btu/Hr ModelsCGP20L - GA4500L - IvoryCGP20 - GA4500 - Earthtone

For locating heater on the floor, away froma wall. Complete installation instructionsincluded.

FAN KITS - GA3100A ANDGA3200TAFor all models. Provides better heat distri-bution. Makes heater more efficient. Com-plete installation and operating instructionsincluded.

Manually controlled - GA3100A. IncludesON/OFF switch.

Thermostatically controlled - GA3200TA.Includes three settings: ON/OFF/AUTO.

Page 18: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

18 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

1

2

4

5

6

7

8

8

9

10

11

12

15

17

19

21

22

23

24

20

27

26

18

14

16

25

3

13

ODS/PILOT

10-110-2

ILLUSTRATEDPARTSBREAKDOWNRP30D

Page 19: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

19103569

OWNER’S MANUAL

PARTS LISTRP30D

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listedunder Replacement Parts on page 16 of this manual.

KEY PARTNO. NUMBER DESCRIPTION QTY.

1 098304-01 Screw, #10 x 3/8" 22 098345-01AC Front Panel 13 103476-02 Grill Guard 14 101108-01 Clip, Grill Guard 25 099001-01BR Heat Shield 16 M11084-26 Screw, #10 x 3/8" 47 098352-02BR Deflector Unit 18 098271-03 Ignitor Cable 19 098249-01 Nut, M5 210 099059-04 ODS/Pilot, L.P. 1 10-1 098514-01 Thermocouple 1 10-2 098594-01 Ignitor Electrode 111 103447-01 Burner 112 099387-05 3/16" Pilot Tubing 113 103845-03 Injector 114 099066-01 Mounting Bracket 115 099415-06 Pressure Regulator 116 099553-01 Pilot Shield 117 103570-01 3/8" Outlet (Burner) Tubing 118 103572-01 3/8" Inlet Tubing 119 100068-01 Pressure Tap Fitting 120 100047-02 Control Valve 121 098529-04 Cabinet 122 097159-04 Piezo Ignitor 123 M11084-26 Screw, #10 x 3/8" 224 M11084-38 Screw, #8 x 3/8" 225 098276-01 1/8" NPT Plug 126 098354-01 Control Knob 127 098508-01 Valve Retainer Nut 1

PARTS AVAILABLE — NOT SHOWN

098306-02 Control Position Decal 1099261-02 Operating Instructions Decal 1100642-01 Assembly, Hardware 1

Page 20: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

20 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

ODS/PILOT

12-112-2

1

2

3

4

5

6

7

8

9

10

10

11

12

13

14

17

1927

21

23

24

25

26

22

29

28

20

16

18 15

ILLUSTRATEDPARTSBREAKDOWNCGP20

CGP20L

Page 21: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

21103569

OWNER’S MANUAL

PARTS LISTCGP20

CGP20L

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listedunder Replacement Parts on page 16 of this manual.

KEY PARTNO. NUMBER DESCRIPTION QTY.

1 098304-01 Screw, #10 x 3/8" 22 098742-03 Front Panel (CGN20) 1

098742-19 Front Panel, Ivory (CGN20L) 13 103476-01 Grill Guard 14 101108-01 Grill Guard Clip 25 098533-04AA Bottom Glass Retainer 16 098260-09 Glass Panel 17 098532-04AA Top Glass Retainer 18 M11084-26 Screw, #10 x 3/8" 49 098352-04BR Deflector Unit 110 098271-03 Ignitor Cable 111 098249-01 Nut, M5 212 099059-04 ODS/Pilot Assembly 1 12-1 098514-01 Thermocouple 1 12-2 098594-01 Ignitor Electrode 113 103446-01 Burner 114 099387-05 3/16" Pilot Tubing 115 103845-01 Injector 116 099066-01 Mounting Bracket 117 099415-06 Pressure Regulator 118 099553-01 Pilot Shield 119 103570-01 3/8" Outlet (Burner) Tubing 120 103572-01 3/8" Inlet Tubing 121 100068-01 Pressure Tap Fitting 122 100047-04 Control Valve 123 098529-06 Cabinet, Woodgrain (CGN20) 1

098529-05 Cabinet, Ivory (CGN20L Only) 124 097159-04 Piezo Ignitor 125 M11084-26 Screw, #10 x 3/8" 226 M11084-38 Screw, #8 x 3/8" 227 098276-01 1/8" NPT Plug 128 098354-01 Control Knob 129 098508-01 Valve Retainer Nut 1

PARTS AVAILABLE — NOT SHOWN

098306-02 Control Position Decal 1099491-07 Operating Instructions Decal 1100642-01 Assembly, Hardware 1

Page 22: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

22 103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

NOTES_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

Page 23: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

23103569

OWNER’S MANUAL

NOTES_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

Page 24: BLUE-FLAME VENT-FREE PROPANE/LP GAS HEATER - Desa … Heaters/103569-01.pdf · OWNER’S OPERATION AND INSTALLATION MANUAL MODELS: CGP20, CGP20L, AND RP30D BLUE-FLAME VENT-FREE PROPANE/LP

KEEP THIS WARRANTY

WARRANTY INFORMATION

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standardwritten warranty. We make no other warranty, expressed or implied.

Model

Serial No.

Date Purchased

LIMITED WARRANTYCOMFORT GLOW VENT-FREE HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the dateof first purchase, provided that the product has been properly installed, operated and maintained in accordance with allapplicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restorethis heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement partsvoids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructionsfurnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail orbecome damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation.Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will bethe responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THEPRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES ANDLIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER-CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRSTPURCHASE: AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OFTHE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSO-EVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental orconsequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not applyto you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

103569-01REV. B9/97

2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004

103569 01NOT A UPC