WISSAHICKON SCHOOL DISTRICT Ambler, Pennsylvania 19002-3496 BOARD OF SCHOOL DIRECTORS FACILITIES/TRANSPORTATION COMMITTEE MEETING AGENDA April 22, 2019 6:30 PM Central Office Board Room FACILITIES 1. Elementary Capacity Discussion Enrollment Projections & Capacity (Attachment A) Addition/Renovation at Stony Creek Elementary Timeline (Attachment B) Modular Permanent Construction Pros and Cons 2. Presentation: Middle School Multi-Use Room (Attachment C) 3. Presentation: High School Athletic Turf Fields (Attachment D) 4. High School Scoreboard (Attachment E) 5. 2019-2022 Service Contract for PM, Inspections and Water Treatment of High School Cooling System Chillers (Attachment F) 6. Blue Bell Run/Walk Trail (Attachment G)

BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

WISSAHICKON SCHOOL DISTRICT

Ambler, Pennsylvania 19002-3496

BOARD OF SCHOOL DIRECTORS FACILITIES/TRANSPORTATION COMMITTEE MEETING AGENDA

April 22, 2019 6:30 PM Central Office Board Room

FACILITIES

1. Elementary Capacity Discussion

Enrollment Projections & Capacity (Attachment A)

Addition/Renovation at Stony Creek Elementary

Timeline (Attachment B)

Modular Permanent Construction – Pros and Cons

2. Presentation:

Middle School Multi-Use Room (Attachment C)

3. Presentation:

High School Athletic Turf Fields (Attachment D)

4. High School Scoreboard (Attachment E)

5. 2019-2022 Service Contract for PM, Inspections and Water Treatment of High School Cooling

System Chillers (Attachment F)

6. Blue Bell Run/Walk Trail (Attachment G)

Page 2: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 1

Page 3: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 2

Page 4: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 3

Page 5: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 4

Page 6: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 5

Page 7: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 6

Page 8: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 7

Page 9: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 8

Page 10: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 9

Page 11: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment A 10

Page 12: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

WISSAHICKON SCHOOL DISTRICT

Stony Creek Elementary School Addition and Renovation

PROPOSED SCHEDULE

April 9, 2019

Hire Architect June 2019

Confirm Educational Program/ Room Schedule July 2019

Complete Schematic Design September 2019

Start Land Development Process October 2019

Approve Design Development/Start Construction Documents December 2019

Complete Land Development Process & Construction Documents June 2020

Release for Bidding July 2020

Receive Bids August 2020

Award Bids September 2020

Notice to Proceed (Start New Construction) October 2020

Begin Summer Renovations (Renovation Part 1) June 2021

Complete Summer Renovations (Renovation Part 1) August 2021

Complete New Construction (14 months) December 2021

Occupy New / Renovate Vacated Areas (Renovation Part 2) January 2022

Substantial Completion June 2022

Complete Punch List July 2022

Occupy Renovation August 2022

Attachment B

Page 13: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS

FEASIBILITY STUDY ALTERATIONS to the

WISSAHICKON MIDDLE SCHOOL NATATORIUM for the

WISSAHICKON SCHOOL DISTRICT

April 22, 2019

Atttachment C

Page 14: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS

TABLE OF CONTENTS

Page INTRODUCTION

I. Purpose of the Study 1

II. Existing Building Description 1

III. Authors’ Credentials and Acknowledgements 1

IV. Auditorium Addition and Renovations 2017-18 2

PROPOSED ALTERATIONS 2019

I. Program 3

II. Schematic Floor Plan Options 3-4

III. Recommendation - Floor Plan Option D 5

IV. Floor Plan Option D 6

V. Construction Details 7-8

VI. Structural Feasibility Study 8

VII. Roofing 9

VIII. Theater Platforms and Seating 9

IX. Estimated Cost for Option D 10 APPENDIX

i. Existing Floor Plans and Natatorium Section

ii. Schematic Floor Plan Options A, A-1, B, C, C-1, D

iii. Partial Roof Plan

iv. Structural Report by D’Huy Engineering

v. Platform Catalog Cuts

Atttachment C

Page 15: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 1 of 10

INTRODUCTION

I. PURPOSE OF THE STUDY

The Wissahickon Middle School natatorium and adjoining locker room areas have been closed and unused since completion of construction of the new high school natatorium in 2017. The purpose of this study is to assess alteration options to create new usable performance and academic spaces to support the middle school curriculum. The school currently does not have a dedicated auditorium or stage; the drama and music programs must utilize the high school for rehearsals and performances.

II. EXISTING BUILDING DESCRIPTION

The construction documents for the original middle school which included the natatorium are dated 1973 (45+ years ago). The Architect of record was Anthony T. Rienzi and Associates from Jenkintown, Pennsylvania. The building construction is comprised of steel framing, concrete slab floors and metal paneled exterior and brick walls backed up by concrete block. The natatorium and adjoining locker room wing have had limited upgrades and remain much as constructed except for the roof which has been replaced. A rooftop Dekton HVAC unit was also added at a later date to help control the natatorium temperature and humidity.

III. AUTHORS’ CREDENTIALS AND ACKNOWLEDGEMENTS

Over the past 55 years, Breslin Ridyard Fadero Architects has earned commissions for over 400 public education projects encompassing more than four billion dollars in construction value and has authored 27 Districtwide studies and hundreds of feasibility studies. The following architects conferred with District Administration, Faculty and Staff who made significant contributions to the completion of this study: ROBIN W. BRESLIN, A.I.A. GWEN H. BRESLIN, A.I.A. Breslin Ridyard Fadero Architects wishes to thank Superintendent Dr. James A Crisfield, Ed.D., Assistant Superintendent Gary W. Abbamont, Principal Elizabeth Bauer, Director of Secondary Teaching and Learning and Assessment Jennifer Schmidt, Business Administrator Wade T. Coleman and Director of Buildings and Grounds Gerry T. Moore for their guidance and contributions to the completion of this study.

Atttachment C

Page 16: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 2 of 10

INTRODUCTION

IV. AUDITORIUM ADDITION AND RENOVATIONS 2017-18 (Not Constructed)

In 2017, the Wissahickon School District sought bids for a construction project for a new auditorium addition for their middle school. The project scope required full demolition of the existing natatorium including the pool shell. A new auditorium and support spaces were to be built where the old natatorium previously stood. Bids were received in April 2018; however, they were significantly higher than anticipated and the project did not advance. Contractors cited the following reasons for their high bids:

• Removal of the concrete foundations, pool structure and affiliated mechanical, electrical and plumbing systems was very difficult and costly.

• Adjacent footings that were to remain in place would require underpinning, which added cost and liability for the contractors.

• There was a significant amount of fill to import from off-site to fill the

areas vacated by the foundation removal.

• Steel prices were elevated and very volatile due to recent federal tariff increases.

• Site access and staging was restricted.

• The summer demolition schedule was aggressive and there were few

available demolition contractors interested in bidding the demolition.

Atttachment C

Page 17: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 3 of 10

PROPOSED ALTERATIONS 2019

I. PROGRAM

The Wissahickon School District is considering construction of a Multi-Use Space. This Multi-Use Space will include an experimental theater which typically has a flat floor and is outfitted with modular, movable platforms to allow for different tiered seating and stage configurations. The platforms and seating can also be installed in a semi-permanent setup if it is determined that they would not be changed on a regular basis. The Multi-Use Space would offer a large scale, flexible space for the middle school that could be utilized for a variety of functions in addition to its use as a theater. The following activities could be accommodated during the school day and during after-school hours.

• Drama Rehearsal • Team Theater Performances, Activities • Music Practice • Large Group / Team Instruction • Long Distance Learning • Large Group Science Demonstrations, Experiments • Competitions, i.e., Mock Reading Olympics, Spelling Bee, Geography

Bee, Shark Tank, etc. • Student Debates • H & SA Meetings • Testing • Indoor Fitness Classes • Extra-Curricular Clubs • After School Organization Use

II. SCHEMATIC FLOOR PLAN OPTIONS

Six Schematic Floor Plan Options A, A-1, B, C, C-1 and D were prepared by Breslin Ridyard Fadero Architects and are included in the Appendix of this report. All options include the following:

• Multi-Use Space • Different seating configurations • An optional accessible lift to a lighting and sound platform at the back of

the theater

Atttachment C

Page 18: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 4 of 10

PROPOSED ALTERATIONS 2019

• Storage Rooms for storage of backdrops, platforms and seating • Classroom(s) that may or may not have a physical connection to the

theater • A vestibule addition on the north side of the school. Currently, there is

not a functioning vestibule. It is recommended to add one as an air lock to reduce outside air infiltration, to facilitate the layout of the new toilet gang rooms, and to move the exterior entry doors closer to the parking lot.

• Gang and single-user toilets. • A Custodial Closet • New Stairs to the second-floor mechanical room • A new corridor and vestibule to provide required means of egress to the

outside

It was suggested to include a concession stand and coat closet. The school district did not wish to include these types of rooms.

Atttachment C

Page 19: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 5 of 10

PROPOSED ALTERATIONS 2019

III. RECOMMENDATION - FLOOR PLAN OPTION D

Option D is the school district’s preferred layout. This option offers the following benefits:

• Two 800+ square foot classrooms, one with the opportunity to have windows and both in proximity to the theater. These classrooms can be used as green rooms, if desired. They are also located closer to the rest of the school in Option D than in the other options.

• A 3,400 square foot theater with an open floor area that could be arranged to simulate the 24’ X 48’ High School stage size. The seating layout provides for 178 seats on tiered platforms.

• A sound/light lock vestibule as a buffer between the theater and the corridor. The other options do not have a vestibule.

• The overall layout is more efficient because there is less corridor space. The new corridor exits directly to the north outdoor patio area.

• The number of walls built across the pool shell is minimized. This is more efficient structurally and therefore more economical.

IV. FLOOR PLAN OPTION D

See following page for Floor Plan Option D.

Atttachment C

Page 20: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Atttachm

ent C

gwenb
Rectangle
gwenb
Rectangle
gwenb
Typewritten Text
Page 6 of 10
gwenb
Typewritten Text
gwenb
Typewritten Text
gwenb
Typewritten Text
Page 21: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 7 of 10

PROPOSED ALTERATIONS 2019

V. CONSTRUCTION DETAILS

Exterior: The existing exterior wall construction would remain intact. The existing roof construction would remain except for the roofing membrane above the alteration areas; this portion of roof was not replaced during the summer of 2018 when other middle school roofs were replaced. The existing rooftop Dekton HVAC unit above the natatorium is not an appropriate HVAC system for the future spaces and is therefore expected to be removed during renovations. The existing HVAC wall louvers will need to be assessed to determine if they will remain or be removed. New doors and possibly windows could be added. Interior Pool Shell: The existing pool shell would remain intact and a new concrete floor slab would span the pool to create a flat floor. Structural options to support the new concrete floor slab are delineated in the attached structural report. The existing pool deck around the outside of the pool slopes to floor drains. Leveling is therefore required for the pool deck as well as for the trough system around the pool’s perimeter. The pool area below the new concrete slab will require ventilation similar to a crawl space; holes will need to be cut into the pool shell at the basement level. Basement: The basement “tunnel” area below the pool shell would remain as is. Unused mechanical, electrical and plumbing lines could be left in place and capped off as determined by the engineers. This would be a cost savings in lieu of removing this infrastructure. If the basement is to be used for storage, it must be heated and ventilated; a second means of egress may also be required by code. Currently, there is ventilation of this space through louvers built into the natatorium benches. Locker Rooms, Bleachers and Mechanical Room: Interior walls are to be demolished within the existing locker room area. The concrete bleachers and stairs accessing the bleachers must be demolished; they are in violation of current UCC 2015 building codes (all alteration areas are required to meet current codes). The second floor mechanical room is recommended to remain. It is stabilizing the structural steel columns that support the roof framing. It can also be reused for new HVAC equipment. Currently, the mechanical room is accessed from the concrete bleachers which are to be demolished. A new stair to the mechanical room must therefore be added. A second means of egress from the mechanical room is required and may be accomplished with a ladder.

Atttachment C

Page 22: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 8 of 10

PROPOSED ALTERATIONS 2019

Toilet Rooms: New toilet rooms are proposed to be constructed in the same vicinity as the existing locker room toilets. It is assumed that the plumbing lines serving the existing toilets can be reutilized for the new toilet rooms. This will help control plumbing costs. Single-user toilets are also recommended to serve faculty, families and transgender students. Multi-Use Space: The ceiling height of the existing natatorium space is appropriate for a Multi-Use Space. The ceiling height will readily accommodate theatrical lighting and will be beneficial for acoustics. The existing acoustic tile ceiling system will be removed to expose the long span joists to allow for a lighting grid to be added. The existing concrete block walls of the natatorium are suitable for acoustical reverberation, however, sound absorptive and reflector panels may be required to modulate the sound.

VI. STRUCTURAL FEASIBILITY STUDY

D’Huy Engineering, Inc., the structural engineers, performed an on-site assessment of the existing natatorium. Using site observations and data, together with information from the existing construction documents, they developed the structural Feasibility Study. The study describes existing site conditions, structural options for spanning the pool shell to create a flat floor, roof framing capacity, demolition and a structural estimate. Of the three options for spanning the pool shell, the “Dual Bearing Line” framing is recommended by the structural engineer as being most cost effective to infill the pool. This type of Cold Formed Metal Framing (CFMF) framing has the benefit of shorter spans which can result in a stiffer floor. Concrete footers are not required under the CFMF because the loads are distributed over a wider area. A footing will be required below the concrete block wall separating the theater from the classrooms in Option D.

Atttachment C

Page 23: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 9 of 10

PROPOSED ALTERATIONS 2019

VII. ROOFING

The roof above the natatorium (outlined in red in the Appendix photo) requires roof replacement; it was not replaced in the summer of 2018 when other adjacent roofs were replaced. The square footage of this area is approximately 9,200 square feet. The owner wishes to use the same Garland 2-ply stress torch system as was used on the other roofs.

VIII. THEATER PLATFORMS AND SEATING

It is recommended to use modular platforms capable of creating different tiered seating and stage configurations. Wenger Corporation manufactures a platform system called “Stage Tek“ that meets this criterion. Catalog cuts are attached in the Appendix. Stage Tek can also be set up by one person. (see Wenger video: https://www.youtube.com/watch?v=lxMeaOJJjXQ). The platform legs are detachable and are available in different heights; this allows the height of platforms to be changed as needed for different set-ups. Stops are available to close off the open riser vertical space between the tiered platforms. Stops are recommended to prevent dropped items from falling below the platforms. They are also required to prevent chair legs from sliding into the opening. Guardrails will be required at the sides of the tiered platforms. Chairs for the platform seating are recommended to be stackable. The school district requested that the seating be upholstered for comfort. During discussions, the school district also requested movable tables to provide flexibility in setting the room up for other uses.

Atttachment C

Page 24: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

BRESLIN RIDYARD FADERO ARCHITECTS Page 10 of 10

PROPOSED ALTERATIONS 2019

IX. ESTIMATED COST FOR OPTION D

WISSAHICKON MIDDLE SCHOOL THEATER RENOVATIONSEstimated Project Cost February 19, 2019

Description:

Construction Costsa. Alterations (9,300SF x $300) $ 2,790,000b. Mechanical Room (800SF x $40) $ 32,000b. New Construction- Vestibule (125SF x $800) $ 100,000c. Special Foundations Allowance (Pool Shell) $ 100,000c. Roof Replacement (9,280SF x $25) $ 232,000

Sub-Total $ 3,254,000

Summary of Construction Costsa. Construction $ 3,254,000b. Architectural and Engineering Fees (7.5%) $ 244,050c. Land Development Fees $ 0

Sub-Total $ 3,498,050Additional Construction Related CostsAdditional Construction Related Costs (includes reports, $ 455,560

agency approval fees, printing, contingency, miscellaneous expenses @ 14% ) Furnishings & Equipment (theatre risers, chairs, and classroom furniture) $ 175,000Technology $ 100,000Construction Supervision $ 60,000Financing Costs including bond discount, legal fees, financial advisor $ 0

Sub-Total $ 790,560

Estimated Project Cost $ 4,288,610

Note: Costs are exclusive of CM fees, LEED certification, site and off-site construction and costs associated with the temporary relocation of staff and services.

Demolish the existing pool locker rooms, bleachers and stairs. Retain the second floor mechanical room and provide new access stair and ladder for second means of egress. Selective demolition in other renovated areas. Install special foundations and new concrete floor slab to infill over the existing pool shell. Level the tile pool deck to receive new finishes. Construct a new blackbox theater, classrooms, storage, gang and single-user toilet rooms. Re-roof over the existing pool roof. Install new MEP infrastructure.

WISSAHICKON SCHOOL DISTRICT

BRESLIN RIDYARD FADERO ARCHITECTS

Atttachment C

Page 25: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment DPage 1

Page 26: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment DPage 2

Page 27: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment DPage 3

Page 28: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment DPage 4

Page 29: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

GYM 2781-2770-10MM LED COLOR MC-V2 PA COSTARS# 014-084

  

www.nevco.comVisit Our Website00089221Quote Number

 

 

USD 31,128.31Total

USD 654.06Freight

USD 30,474.25Subtotal

MontgomeryCounty

875Ttl Shipping Wt (lbs)

[email protected] Address

(610) 247-4356Phone

Display and Scoring ConsultantTitle

Mark HubertPrepared By

[email protected] Address

(610) 247-2555Phone

Director of AthleticsTitle

Jim CairnesContact Name

12/16/2018Expiration Date

12/6/2018Created Date

00089221Quote Number

Wissahickon High SchoolAccount Name

Quantity Model/Part # Product DescriptionPixels (H xW)

Dimensions L x H xW/D

Total Price

1.00 2781-ICBasketball/Volleyball/Wrestling LED Scoreboard w/Intelligent Captions

  10'x4'11"x8"USD

7,636.00

1.00 2770-NL Basketball/Volleyball/Wrestling LED Scoreboard   8'x5'11"x8"USD

3,238.40

2.00 MPCW-7 Indoor Rec Receiver MPCW-7 (Wireless) for indoor scoreboards     USD 848.24

1.00 MPCW-7 Controller MPCW-7 (Wired or Wireless)   0.9'x0.8'x4" USD 914.48

1.00 MC-10mm-C-SS-3x10-v2 3'x10' - 10mm Full Color LED Indoor Message Center 72x288 10'x3'x8"USD

15,232.85

1.00 275-0727 Disp Dir ST DISPLAY DIRECTOR - SCORERS TABLE    USD

2,550.00

1.00 MPC(W) Case MPC/ MPCW Control Carrying Case   1.7'x1.1'x8" USD 54.28

Customers who purchased items in this quote also purchased the following:

Attachment E Page 1

Page 30: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

GYM 2781-2770-10MM LED COLOR MC-V2 PA COSTARS# 014-084

  

www.nevco.comVisit Our Website00089221Quote Number

 

 

 

 

Attachment E Page 2

Page 31: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

GYM 2781-2770-10MM LED COLOR MC-V2 PA COSTARS# 014-084

  

www.nevco.comVisit Our Website00089221Quote Number

 

Signature ____________________________________________          Title _______________________________________________

Name _______________________________________________          Date _______________________________________________

Nevco Sports, LLCP.O. Box 74758

Chicago, IL 60694-4758800.851.4040 / 618.664.0360

Remit To AddressNevco, Inc.301 East Harris Ave

Greenville, IL 62246-2151

Purchase OrderAddress

 

The above pricing is for equipment only and does not include installation (unless specified) or taxes (if applicable). Unlessshown specifically in the quote, shipping is an additional cost and is not included. Credit terms determined upon receipt ofpurchase order. Shipping terms are F.O.B. Greenville, IL USA.

All Scoreboards and Message Centers are UL Listed and most come with our free 5-year guarantee (Exception: Specialpromotion/packages may have shorter warranty and are noted in product descriptions). Wireless components, UltraScorePortable Scoreboard and Solar Power Kit carry a 2-year guarantee. Hand-held controls and switches carry a 1-yearguarantee.

Scoreboards are available in 15 standard colors at no extra charge. Please contact your consultant for production/shippinglead times.

Wissahickon High SchoolShip To Name

Ambler, PABill To

Wissahickon High SchoolBill To Name

 

 

Billing/Shipping Information

Quote Terms and Conditions

Quote Acceptance

Attachment E Page 3

Page 32: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment E Page 4

Page 33: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment E Page 5

Page 34: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

WISSAHICKON SCHOOL DISTRICT Ambler, Pennsylvania 19002-3496

M E M O DATE: April 8, 2019 TO: Wade Coleman FROM: Gerry Moore RE: Service Contract for Preventative Maintenance, Inspections and Water Treatment of the High School Cooling System Chillers 2019-2022. The High School Central Plant has three (3) air cooled chillers manufactured by Johnson Controls’ York Division. The chillers require routine maintenance to guarantee peak performance and longevity of the building’s cooling system. Johnson Controls offers specially trained mechanics to service such machines, with rates offered through General Services Administration (GSA) Contract. Included with installation of the chillers, was a full system parts and labor warranty until September 2020. This warranty does not include routine maintenance. The Johnson Controls’ three-year proposal includes preventative maintenance, inspections, water treatment and winterization of the High School cooling system chillers beginning July 1, 2019. It is recommended to award the Service Contract for Preventative Maintenance, Inspections, Water Treatment and Winterization of the High School Cooling System Chillers to Johnson Controls, per GSA -Contract #06F-0060P in the amount of $18,831 for 2019-20, $19,373 for 2020-21 $20,030 for 2021-22.

Attachment F

Page 35: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment G Page 1

Page 36: BOARD OF SCHOOL DIRECTORS...Apr 22, 2019  · See following page for Floor Plan Option D. Atttachment C. Atttachment C. Page 6 of 10. ... ventilation similar to a crawl space; holes

Attachment G Page 2