Battery Capacity TestTORKEL

Bob van Evelingen

www.programmabob.nl

Programmabob.nl

STOPALARMVOLTAGE DROP

I or Ah = ConstantI or Ah = Constant

Testing Capacity BatteriesTORKEL & TXL

+-+-

Installation

Charger=off

TXL for Higher Loads

TORKEL Win

Page 2: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

2

Programmabob.nl

TORKEL 820 Telecom12 - 48 V batteries, up to 270 A, 15 kW.

TORKEL 840 Utility12 - 250 V batteries, up to 110 A, 15 kW.

TORKEL 860 Multi12 - 480 V batteries, up to 110 A, 15 kW.

For higher currents, extra load units can be added

Programmabob.nl

TORKEL 800-Serie

Battery Load

APPLICATIONS

Capacity tests with constant current or constant power

Test of chargers

Testing according to a load profile

Weight:TORKEL approx. 20 kgTXL approx. 13 kg

Page 3: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

3

Programmabob.nl

I

t

CURRENT or POWER PROFILE

According to profile stored previously in TORKEL:Specify time and current or power for each stepUp to 19 steps in a profile9 current and 9 power profiles can be stored

Programmabob.nl

CURRENT MEASUREMENT

TORKEL measures the current and bases the regulation on:

current through TORKEL

current in an external circuit measured with a DC clamp-on ammeter

Page 4: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

4

Programmabob.nl

TORKEL & Extra Load TXL

Programmabob.nl

VOLTAGE MEASUREMENT

At the input terminals on TORKEL

At the battery terminals

MAIN SUPPLY

No mains supply required at battery voltage 95 V - 300 V

Page 5: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

5

Programmabob.nl

2 x 3 m 70 mm2

270 A

CABLE SET FOR TORKEL 820

2 x 3 m 25 mm2

110A

CABLE SET FOR TORKEL 840 & 860

Programmabob.nl

LIMIT VALUES

Six independent limit values:

Warning at voltage level, time or capacity

Automatic stop at voltage level, time or discharged capacity

Page 6: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

6

Programmabob.nl

EXTERNAL CONTROL

Start, stop, and setting the load possible from PC software, e.g. TORKEL Win

Start and stop from external equipment by a contact closure

ALARM output

Programmabob.nl

DISPLAY

Current VoltageTimeDischarged capacity

TEST METHODS

Constant Current Constant PowerConstant Resistance

Current ProfilePower Profile

Page 7: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

7

Programmabob.nl

Programmabob.nlPreparations for Testing

Page 8: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

8

Programmabob.nlConnect Current Cables

Programmabob.nlSetting the Current

Page 9: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

9

Programmabob.nl

Programmabob.nlAlarm Setting & Start

Page 10: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

10

Programmabob.nlTORKEL Win

Programmabob.nlTime, voltage, current and capacity

Voltage curve built up during the test

Last Recorded Time

Page 11: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

11

Programmabob.nl

STOPALARMVOLTAGE DROP

I or Ah = ConstantI or Ah = Constant

Testing Capacity BatteriesTORKEL & TXL

+-+-

Installation

Charger=off

TXL for Higher Loads

TORKEL Win

Programmabob.nl

TORKEL

TIME-SAVING AND CONVENIENT

Automatic regulation - you do not need to spend time and attention on adjusting the current

Alarm when voltage approaches end-of-test voltage

Higher current - shortened testing time(also reduces recharging time)

Page 12: Bob van Evelingen Battery Capacity Test TORKEL www ... · load profile Weight: TORKEL approx. 20 kg TXL approx. 13 kg. 3 Programmabob.nl I t CURRENT or POWER PROFILE According to

12

Programmabob.nl

www.programmabob.nl