23
BOB, 27th floor, Gift City, Ahemdabad S.No. DESCRIPTION Amount (Rs) A) MV PANEL BOARDS B) MV CABLES C) SAFETY EQUIPMENTS D) DISTRIBUTION BOARDS E) POINT WIRING F) ELV SYSTEM (DATA/TELE) G) TELEPHONE SYSTEM H) IP CCTV SYSTEM I) ACCESS CONTROL SYSTEM J) SENSOR SYSTEM K) TV SYSTEM L) LIGHTING FIXTURES (MAKE : PHILPS/ WIPRO / CROMPTON / HALONIX) M) FIRE ALARM SYSTEMS N) PA SYSTEM FOR FIRE ALARM O) EARTHING P) FIRE SUPPRESSION SYSTEM Q) VIDEO SYSTEM R) RODENT PROTECTION SYSTEM I TOTAL - II GST EXTRA AS APPLICABLE ELECTRICAL BOQ FOR BOB OFFICE AT 27TH FLOOR GIFTCITY, GUJARAT BOQ Electrical BOQ 1

BOQ - Bank of Baroda

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

BOB, 27th floor, Gift City, Ahemdabad

S.No. DESCRIPTION Amount (Rs)

A) MV PANEL BOARDS

B) MV CABLES

C) SAFETY EQUIPMENTS

D) DISTRIBUTION BOARDS

E) POINT WIRING

F) ELV SYSTEM (DATA/TELE)

G) TELEPHONE SYSTEM

H) IP CCTV SYSTEM

I) ACCESS CONTROL SYSTEM

J) SENSOR SYSTEM

K) TV SYSTEM

L) LIGHTING FIXTURES (MAKE : PHILPS/ WIPRO / CROMPTON / HALONIX)

M) FIRE ALARM SYSTEMS

N) PA SYSTEM FOR FIRE ALARM

O) EARTHING

P) FIRE SUPPRESSION SYSTEM

Q) VIDEO SYSTEM

R) RODENT PROTECTION SYSTEMI TOTAL -

II GST EXTRA AS APPLICABLE

ELECTRICAL BOQ FOR BOB OFFICE AT 27TH FLOOR GIFTCITY, GUJARAT

BOQ

Electrical BOQ 1

BOB, 27th floor, Gift City, Ahemdabad

III

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

i)

ii)

iii)

iv)

v)

vi)

vii)

9.0

10.0

11.0

12.0

13.0

14.0

15.0

All Electrical panel must have provision of potential free contacts for BMS/FAS.

All Electrical panel must have digital type energy meter with RS 485 port.

The installation and testing shall also be as per specifications and as per direction and satisfaction of Engineer in charge.Network switches warranty shall be as per OEM policy.

Contractor shall submit the shop drawings for approval by consultants / Engineer in charge. The work shall be carried out asper the approved shop drawings.

Panels shall be fabricated as per specifications after approval of fabrication drawings by consultant / Engineer incharge.

The work shall be executed as per relevant specification and drawings.

All material and equipment shall be as per specification and as per approved makes of material. Where specifications are notavailable the material shall be as per Indian standard specifications. The quantities and capacities of the equipments shallmeet the requirement for successful completion of the work.

GRAND TOTAL AMOUNT (Rs)

Wastage on material and labour.

Loading, unloading, handling charges, hoisting the material to all upper levels.

The rates of all the items of the BOQ shall include the cost of :-

All materials, fixing hardware, accessories, tools and plants, freight, insurance, labour, taxes, duties, testing commissioningand of the work, as per specifications and drawings.

Execute the work as per specifications and drawings to the full satisfaction of engineer incharge.

All liabilities, obligations and risks arising out of conditions of contract.

All requirements for successful completion of the work whether mentioned in BOQ, specifications land drawings or not.

In the event of conflict between BOQ, specifications and drawings, the most stringent shall apply. The decision of Architect /Engineer incharge / Consultant shall be final and binding.

The quantities of the items in the BOQ are for general guidance only based on the Architect / consultants drawings anddocuments. The contractor shall be paid for actual quantities as per schedule rates.

Contractor shall visit the site before quoting the rates and satisfying himself about the working conditions. Since this is a tallbuilding, hoisting/lifting the material to upper levels may be taken into account white quoting the rates. No extra claim onthis account shall be entertained.

Price bid shall be submitted online only

Totaling errors or missing amounts shall be corrected and incorporated in tendered amount.

Approval of all makes of material to be supplied out of approved list, shall be obtained by the contractor. Sample of thematerial shall be kept at site to check with the material actually installed at site.

Engineer in charge may get the material tested at authorized labs. In case material is found under specifications as per IS,same shall be replaced by the contractor. The test fee for 1st test shall be borne by the client but for subsequent test, fee due tofailure of first sample, would be borne by the contractor.

Testing and commissioning shall be carried out as per IS 732-1989 for the installation. The record of test results shall bemaintained and submitted to the engineer in charge who would check the same at random.

Electrical BOQ 2

BOB, 27th floor, Gift City, Ahemdabad

16.0

17.0

18.0

19.0

20.0

21.0 As built drawing shall be prepared by the contractor after successful completion of the work these drawings shall incorporate

the actual layouts, routes of cables and conduits with sizes, locations of outlets, DBS switch rooms panel, Tag blocks

EPABX, Switches servers, fire detectors, zonal and main fire panels, location of CCTV cameras, monitors, etc. sets of blue

prints of switch drawings shall be submitted to the Engineer incharge for verification with actual layout at site and for record.

All connections shall be through, aluminium ferrules for aluminum conductors and copper ferrules for copper conductorcables.

Continuous earth wire shall run alongwith circuit wiring and point wiring. All switch boxes and fixtures shall be earthed.

Where only conduits are laid for other services 16 SWG steel wire shall run in the conduit for pulling the wires at later date,by other agencies.

Earth wire with point wiring, circuit wiring, shall be of green colour with solid conductor.

DBs shall be circuit numbered.

Electrical BOQ 3

BOB, 27th floor, Gift City, Ahemdabad

S.No. Description Unit Qty. Rate (Rs) Amount (Rs)

A) MV PANEL BOARDS

Design, fabrication, loading, unloading at store,Supply, installaton, testing &commissioning as directed by Engineer-in-Charge, of LT Panels fabricated out of2mm thick for structural members (Load bearing members) and 1.6mm thick for doorand covers (Non load bearing members) CRCA sheet in cubicle compartmentalizefree standing floor mounted, dust and vermin proof with reinforcement of suitable sizeangle iron, channel 'T' irons and / or flats wherever necessary, 16 gauge CRCA sheetsteel shall be used for final distribution panels. Cable gland plates shall be providedon top as well as at the bottom of the panels. Panels shall be treated with allanticorrosive process before painting as per specifications with 2 coats of zincchromate primer and final approved shade of enamelled paint. 2 Nos. earthingterminals shall be provided for all distribution panels. Panels shall be suitable for415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooksshall also be provided in case of large panels. Panel must be BMS/FAS Compatible.

Approval shall be taken for each panel before fabrication. Galvanized hardwares withzinc passivation shall be used in fabrication of panels.

General Notes:

1.0 MCCB:MCCBs shall be used with Thermal Magnetic Based releases upto 250A andmicroprocessor based Over Load, Short Circuit / Earth Fault release.

2.0 Breaking capacity mentioned is Ics value.

3.0 This BOQ to be read in conjunction with technical specifications and Single LineDiagram (attached for reference). If any discrepancy occurs that should be brought tothe notice of Client/Consultant before quoting the price otherwise stringent conditionwill be deemed to have been considered.

4.0 All MCCBs shall be provided with rotary operating handle and ON/OFF lamps.

5.0 All meters shall be digital type (unless otherwise specified) with RS 485 Port.

6.0 All Incoming and outgoing breaker must have provision of Potential free contacts forBMS/FAS.

7.0 All MCBs shall be motor duty type.

8.0 All current/voltage transformer shall be cast resin type.

9.0 All indicating lamps shall be LED type.

10.0 Current density for Cu. bus bars shall not be more than 1.6A/Sqmm. Rating of Busbar is after considering all derating factors. (Bus bar sizing calculation to be submittedfor approval.)

11.0 All internal control wiring shall be heat resistant type.

12.0 All TP feeders shall be provided with Isolable neutral link.

13.0 Bus bar chamber & cable entry both shall be provided at top only.

14.0 All feeders shall be provided with door interlocked with door defeat, pad lock facility.

15.0 Live parts shall not be accessible after opening the door, Transparent acrylic sheet tobe provided to cover the same.

16.0 Spare contacts of MCCBs / Relay / Contactor shall be wired upto terminal block.

17.0 20% spare control terminal to be provided.

Electrical BOQ 4

BOB, 27th floor, Gift City, Ahemdabad

18.0 All incoming/outgoing cables shall be terminated on links/terminals.

1.0 MAIN PANEL :Supply,Installation, testing & commissioning of compartmentalized Fabricated typepowder coated Power & Lighting Distribution boards as per Drawing, Specification.The unit rate shall include loading/unloading, shifting from site store to the place ofinstallation, assembling the Panel including mounting & wiring of loose parts bymanufacturers, interconnection of shipping sections, installation on readymade Cabletrench (provied support for panel mounting) or directly on floor, assembling of looseaccessories supplied by the manufacturer, wiring & connection of auxiliary circuits,installation, testing & commissioning of all Panel, interlocking and supply of allnecessary hardware. Aligning, levelling, grouting, testing and setting of relays andmeters including all hardware. ( 400Amp Cu Busbar 100% Nutral)

INCOMER :--1No. 400Amp. FP MCCB (36KA) with rotary handle, sperader link , on-off, trip indicator…1 No. digital Multifunction Meter for measurement with all pera meters, RS-485 port,

BMS compitible with selector Push button and one set of CTs of ratio 400A/5A, CL

1.0, 15VA (RISH DELTA ENERGY of RISHABH or Equivalent)OUTGOING :--12No. 63A-100A FP MCCB,1 Nos. 160A FP MCCB with require internal wiring, busbar,powder coated enclouser etc. as per requirment.

1.01 UPS PANEL :IncomerThree (3) Nos. 125A, 4P MCCB 25KA , connected as per SLD, to form a By-passarrangement.One (1) No.125A, 4P MCCB (25 kA)

2 No. digital Multifunction Meter for measurement of voltage and current with selectorPush button and one set of CTs of ratio 125A/5A, CL 1.0, 15VA (RISH DELTAENERGY of RISHABH or Equivalent)6 Nos. phase indication lamps and 3 Nos. status indication lamp for ON/OFF/Trip withback up SPMCB.

Busbar 200A TPN Cu busbar of short circuit withstand capacity 36 kA. Bus bar shall beinsulated with heat shrinkable sleeves and shall be color coded.

Nos. 1 0

Nos. 1

Electrical BOQ 5

BOB, 27th floor, Gift City, Ahemdabad

Outgoing4 Nos. 63A 4P MCCB.

4 Nos. 40/63A DP MCB.

TOTAL CARRIED OVER TO SUMMARY

B) MV CABLES

1 Supplying, Laying, testing & commissioning of the following sizes of XLPE Al.

Conductor armoured cables of 1.1KV grade on the surface of wall or on existing cable

trays complete with hangers, properclamps fixing hardware etc. as required

a) 3.5 C x 185 Sq. mm Al. Cable Mtrs 245b) 3.5 C x 70 Sq. mm Al. Cable Mtrs 315c) 4 C x 50 Sq. mm Al. Cable Mtrs 85d) 4 C x 35 Sq. mm Al. Cable Mtrs 165e) 4 C x 25 Sq. mm Al. Cable Mtrs 225f) 4 C x 16 Sq. mm Al. Cable Mtrs 280g) 4 C x 10 Sq. mm Cu. Cable Mtrs 125h) 4 C x 6 Sq. mm Cu. Cable Mtrs 175i) 4 x 25 sqmm Copper Wire with conduit ( For, UPS input ) Mtrs 175

2 Supplying, making, testing & commissioning of end termination with brass mettalic

double compression glands suitable for the following sizes of XLPE Al. conductor

arnoured cables including proper sizes of copper thimbles etc. as required.

a) 3.5 C x 185 Sq. mm Al. Cable Nos. 6b) 3.5 C x 70 Sq. mm Al. Cable Nos. 4c) 4 C x 50 Sq. mm Al. Cable Nos. 6d) 4 C x 35 Sq. mm Al. Cable Nos. 8e) 4 C x 25 Sq. mm Al. Cable Nos. 12f) 4 C x 16 Sq. mm Al. Cable Nos. 6g) 4 C x 10 Sq. mm Cu. Cable Nos. 6h) 4 C x 6 Sq. mm Cu. Cable Nos. 10i) 4 x 25 sqmm Copper Wire with conduit Nos. 10

3 Supply and installation of following sizes of perforated GI cable tray made cut of 2mm thick GI sheet, suspended from the ceiling or fixed on wall/column etc completewith suspenders, runners and fixing hard ware etc. as required.

a) 50 mm x 450mm x 50 mm Mtrs 75b) 50 mm x 300mm x 50 mm Mtrs 110c) 50 mm x 150 mm x 50 mm Mtrs 230

4 Supplying to site and installation in floor including chase cutting of floor,leveling,refilling and making good the same from 1.6 mm thick and 2 mm thick coverpregalvanised MS CRCA sheet, totally enclosed, height 40 mm . The two lengths ofraceways shall be fitted with Collars , 50 mm wide, 3 mm thick , press fit type. Theraceways shall be clamped to the floor slab with GI clamps , 3mm thick and shall bescrewed to the floor slab. The joint between raceway and junction box will be madewith GI flexible strip( 3 nos), 3 mm thick, 4 inches long ,15 mm wide which will be nutbolted to the Junction box complete as required etc.

a) 50MM X 38MM x1.6 MM Mtrs 50b) 100MM X 38MM x1.6 MM Mtrs 150c) 150MM X 38MM x1.6 MM Mtrs 100d) 200MM X 38MM x1.6 MM Mtrs 170

e) 300MM X 38MM x1.6 MM Mtrs 150f) 300MM X 38MM x 2 MM Mtrs 75

Electrical BOQ 6

BOB, 27th floor, Gift City, Ahemdabad

5.0 Supplying to site and installation of Junction boxes for Floor and Ceiling racewaysmade from 2 mm thick , with 2.5 mm thick GI cover including providing neoprenegaskets between the cover and the junction box, cadmium plated flat/round headscrews, height as per site condition,totally enclosed. Proper cutouts shall be made inthe side walls for raceway entry wherever required. The junction box shall be all sidewalls should be welded expect top cover and all side walls shall have suitable size ofrectangular knock out holes for taking raceways / conduits as required and not acomplete cut out. The top cover should be sealed with M Seal to make it dust andwater proof complete as required etc.

Electrical BOQ 7

BOB, 27th floor, Gift City, Ahemdabad

a) 150MM X 150MM x 60-75 MM Nos. 25b) 250MM X 250MM x 60-75 MM Nos. 21

c) 350MM X 350MM x 60-75 MM Nos. 35d) 400MM X 400MM x 60-75 MM Nos. 10

6.0 100MMx50MM PVC trunking with end cap and coplar Supply & Fixing. Mtr. 80

TOTAL CARRIED OVER TO SUMMARY

C) SAFETY EQUIPMENTS

1.0 Supplying & fixing or Rubber matting of 12 mm thick, 1 Mtrs wide suitable for voltageof 1.1 KV etc. as required.

Sq.Mtrs 20

2.0 Supplying & fixing of Shock treatment chart printed in atle;ast three languages i.e,Hindi, English and a local language fitted in wooden frame and glass at front side andhard board at back side etc. as required.

Nos. 1

Electrical BOQ 8

BOB, 27th floor, Gift City, Ahemdabad

3.0 Providing & fixing of MV / HV Danger Notice Plate of 200 mm x 150 mm ,made of mildsteel at least 2mm thick and vitreous enameled, white on both side & with inscriptionin signal red colour on front side as required.

Nos. 2

4.0 Supplying and fixing of carbon dioxide type fire extinguisher 4.5 kgs. capacity ofapproved make with wall mounting bracket (Push type) as required conforming to IS:15683-2006 (Latest ammended) .

Nos. 4

TOTAL CARRIED OVER TO SUMMARY

D) DISTRIBUTION BOARDS

Supplying, installation, testing & commissioning of following type wall mounted

Horizontal TPN/SPN distribution board of double door type design made out of MS

sheet with supplying and fixing following accessories including painting,

interconnections, painting, earthing and labeling etc. as required.

1.0 12 WAY TPN DB Incoming

a) 63Amp TPN MCB (10KA) - 1 No

63Amp DP RCCB (30mA) - 3 Nos

Busbarsa) 100 Amp TPN copper busbars - 1 Set

Outgoinga) 10/16/20/25 Amp SP MCB (10KA) - 36 Nos

Neutral links - 3 Nos (Separate for each phase)

2.0 8 WAY TPN DB Incoming

a) 63Amp TPN MCB (10KA) - 1 No

63Amp DP RCCB (30mA) - 3 Nos

Busbarsa) 100 Amp TPN copper busbars - 1 Set

Outgoinga) 10/16/20/25 Amp SP MCB (10KA) - 24 Nos

Neutral links - 3 Nos (Separate for each phase)

3.0 6 WAY TPN DB Incoming

a) 63Amp TPN MCB (10KA) - 1 No

b) 63Amp DP RCCB (30mA) - 3 Nos

Busbarsa) 100 Amp TPN copper busbars - 1 Set

Outgoinga) 10/16/20/25 Amp SP MCB (10KA) - 18 Nos

b) Neutral links - 3 Nos

Set 8

7

Set 5

Set

Electrical BOQ 9

BOB, 27th floor, Gift City, Ahemdabad

(Separate for each phase)

4.0 250 Amp. 4 P ,25KA MCCB with Box for UPS Set 2

TOTAL CARRIED OVER TO SUMMARY

E) POINT WIRING

1.0 Wiring for switch controlled Light Point with 3 x 1.5 Sq. mm PVC insulated FRLSmultistrand copper conductor 1100 Volt grade wires in recessed/surface MMSFRLS PVC conduit with accessories including cost of providing saddles etc forsurface conduiting and/or cost of cutting and filling chases for recessed conduitingand including the cost of supplying and fixing a 6 Amp 240 Volt grid plate mountedswitch with moulded cover plate in zinc chromate passivated MS box, and costingcircuit wiring with 3 x 2.5sq. mm 1100 volt grade PVC insulated FRLS Multistrandcopper conductor wires, in PVC conduit complete as per specifications and asrequired.

(i) Primary Point Points 40

(ii) Secondary Point Points 80

2.0 Wiring for MCB controlled Light Point with 3 x 1.5 Sq. mm PVC insulated FRLS

multistrand copper conductor 1100 Volt grade wires in recessed/surface MMS

FRLS PVC conduit with accessories including cost of providing saddles etc for

surface conduiting and/or cost of cutting and filling chases for recessed conduiting.

(i) Primary Point Points 120

(ii) Secondary Point Points 385

3.0 Wiring for 5 pin 6 A Light plug point with 3 x 1.5 Sq.mm PVC insulated FRLSmultistrand copper conductor 1100 Volt grade wires in recessed/surface MMS FRLSPVC conduit with accessories including cost of providing saddles etc for surfaceconduiting and/or cost of cutting & filling chases for recessed conduiting, including thecost of providing & fixing 1 No. Modular type 3 pin 6 A socket outlet controlled by 6 Aswitch in zinc chromate passivated MS box, and circuit wiring with 3 x 2.5 sq mmcomplete as per specfications and as required.

Points 20

4.0 Wiring for 3 nos. 5 pin 6 A Light plug point below table, controled by 16 A Switch ontable top with 3 x 2.5 Sq.mm PVC insulated FRLS multistrand copper conductor 1100Volt grade wires in recessed/surface MMS FRLS PVC conduit with accessoriesincluding cost of providing saddles etc for surface conduiting and/or cost of cutting &filling chases for recessed conduiting, including the cost of providing & fixing 1 No.Modular type 3nos.5 pin 6 A socket outlet controlled by 6 A switch in zinc chromatepassivated MS box, and circuit wiring with 3 x 2.5 sq mm complete as perspecfications and as required.

Points 495

5.0 Wiring for following. 13 A Socket controlled by 1 No. 16A Switch with 3 x 2.5 Sq. mmPVC insulated FRLS multi strand copper conductor 1100 Volt grade wires inrecessed/surface MMS FRLS PVC conduit with accessories including cost ofproviding saddles etc for surface conduiting and/or cost of cutting chases forrecessed conduiting, including the cost of providing & fixing 1 No. Modular type 20 Asocket outlet controlled by 1 No. 6 A switch in zinc chromate passivated MS box,complete as per specification and as required.

Points 40

6.0 Wiring for following. 2 Nos. 5 pin 6 A Power plug point controlled by 1 No. 16A Switchwith 3 x 2.5 Sq. mm PVC insulated FRLS multi strand copper conductor 1100 Voltgrade wires in recessed/surface MMS FRLS PVC conduit with accessoriesincluding cost of providing saddles etc for surface conduiting and/or cost of cuttingchases for recessed conduiting, in zinc chromate passivated MS box, complete asper specification and as required.

Points 495

Electrical BOQ 10

BOB, 27th floor, Gift City, Ahemdabad

7.0 Wiring for ceiling/wall fan Point with 3 x 1.5 Sq. mm PVC insulated FRLS multi strandcopper conductor 1100 Volt grade wires in surface / recessed, PVC conduit withaccessories including cost of providing saddles etc for surface conduiting and/or costof cutting and filling chases for recessed conduiting and including the cost ofsupplying and fixing a 6 Amp 240 Volt grid plate mounted switch & 300W electronicregulator with moulded cover plate in zinc chromate passivated MS box, andincluding the cost of circuit wiring with 3 x 2.5sq. mm 1100 volt grade PVC insulatedFRLS multi strand copper conductor wire, inPVC conduit complete as perspecifications and as required.

Points 15

8.0 Wiring for exhaust fan Point with 3 x 1.5 Sq. mm PVC insulated FRLS multi strandcopper conductor 1100 Volt grade wires in surface / recessed PVC conduit withaccessories including cost of providing saddles etc for surface conduiting and/or costof cutting and filling chases for recessed/surface MMS FRLS PVC conduit andincluding the cost of supplying and fixing a 6 Amp 240 Volt grid plate mounted switchwith moulded cover plate in zinc chromate passivated MS box, and including the costof circuit wiring with 3 x 2.5sq. mm 1100 volt grade PVC insulated FRLS multi strandcopper conductor wire, complete as per specifications and as required.

Points 6

9.0 Wiring for 16A Single Phase metal clad socket outlet with 3 x 2.5 sqmm PVCinsulated FRLS multistrand copper wire of 1100 volt grade in recessed/surfaceMMS FRLS PVC conduit with accessories including supply and fixing 16A 3 pinmetal clad plug and socket and 16A SP MCB (MD) in IP 44 Poly carbonate boxcomplete as per specification and as required.

Point 10

10.0 Wiring for 20A Single Phase metal clad socket outlet with 2 x 4 +1 x 2.5 sqmm PVCinsulated FRLS multistrand copper wire of 1100 volt grade in recessed/surfaceheavy duty FRLS PVC conduit with accessories including supply and fixing 20A 3pinmetal clad plug and socket and 20A SP MCB (MD) in IP 44 Poly carbonate box

complete as per specification and as required.

Points 10

11.0 Wiring for 32A Single Phase metal clad socket outlet with 3 x 6 sqmm PVC insulatedFRLS multistrand copper wire of 1100 volt grade in recessed/surface heavy dutyFRLS PVC conduit with accessories including supply and fixing 32A 3pin Metal cladplug & socket and 32A SP MCB (MD) in IP 44 Poly carbonate box complete as perspecification and as required.

Points 4

12.0 Wiring for 20A 3 Phase metal clad socket outlet with 4 x 4 sqmm + 2 x 2.5 SqmmPVC insulated FRLS multistrand copper conductor wire of 1100 volt grade in

recessed/surface heavy duty FRLS PVC conduit with accessories including supplyand fixing 20A 5pin metal clad plug and socket and 20A 4P MCB (MD) in IP 44 Polycarbonate box complete as per specification and as required.

Point 2

13.0 Wiring for 32A 3 Phase metal clad socket outlet with 4 x 4 sqmm + 2 x 2.5 SqmmPVC insulated FRLS multistrand copper conductor wire of 1100 volt grade in

recessed/surface heavy duty FRLS PVC conduit with accessories including supplyand fixing 32A 5pin metal clad plug and socket and 32A 4P MCB (MD) in IP 44 Polycarbonate box complete as per specification and as required.

Points 2

Electrical BOQ 11

BOB, 27th floor, Gift City, Ahemdabad

14.0 Providing and fixing of following sizes of PVC Flexibale Conduits suitable for various

applications, halogen free, oil and petrol resistant, flame retardant, self extiguishing,

high compressive strength and good wearing properties along with connectors

complete with conduit gland & all accessories required. a) 25mm dia RM 6502.0 Supply & fixing the following sizes of PVC conduit in recessed or on surface of wall .

False ceiling including cutting the wall and making good the same as required.a) 25 mm dia Mtrs 1650

15

Supply, Laying & connection of 3x1.5 sq.mm copper flexible FR wires from DB/Panelto switch board / Power Point in 25mm Dia. MMS PVC conduit in wall / slab / floor.The unit rate shall include rate of Supply, Laying & connection of pipes & wires. RM 800

16

Supply, Laying & connection of 2x2.5 sq.mm & 1#1.5 sq.mm copper flexible FR wiresfrom DB/Panel to switch board / Power Point in 25mm Dia. MMS PVC conduit in wall /slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes &wires.

RM 4500

17

Supply, Laying & connection of 2x4.0 sq.mm & 1x2.5 sq.mm copper flexible FR wiresfrom DB/Panel to switch board / Power Point in 25mm Dia. MMS PVC conduit in wall /slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes &wires.

RM 2500

18.00 Supply and installation of SS 304 grade 2 to 2.5mm thick SS floor plate on junctionbox 400mm x 400 mm with champhered edges

nos. 134

TOTAL CARRIED OVER TO SUMMARY

F) ELV SYSTEM (DATA/TELE)

LAN SYSTEM1.0 Supplying and drawing of UTP 4 pair CAT 6A 23AWG LSOH LAN Cable in the

existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6A LHOSUnshielded, Twisted Pair (U/UTP) Cable 500 mtr per Box. Yellow (RAIL 1018) incolour conforming to the following standards like EIA/TIA 568-C.2, EN50173,EN52288, IEC 11801, IEC 61156-5, 500Mhz etc. Cat 6A U/UTP cable with minimumbending radius when laying(mm) is 36. (Make : Legrand / Panduit - Pannet/Siemon).

Mtrs. 45000

2.0 Supplying, installing, testing and commissioning of Cat 6A UTP , Tool lessInformation outlet for Data. Cat6A U/UTP built in crimping hands-free, minimum 5times reconnection possibilities. LCS2 Toolless RJ45 Information outlet whereinsertion test (in & out) must be 2500 times (I/O) along with front side Label holdedand projection white in colour, including front plate and anodised GI box in concealedmanner of adequate sizes, including all fixing accessories. Standard & Approval : ISO11801 2nd ED, EN 50173 2nd ED, EIA/TIA-568-B.2, NF C 20730, Standard 8077 -603.7 (Make : Legrand / Panduit - Pannet/Siemon).

Nos. 525

3.0 Supplying, installing, testing and commissioning of 48 port 1U Cat 6A UTP PatchPanels available with block of four equipped with tool less IO, Rack Mountable. 19"Modular Patch Panel, loaded CAT6A U/UTP 24 port LCS2 rack mountable to becompatible in 4nos of 6 X RJ 45 Tool less connector U/UTP unit in a block. Standard& Approval : ISO 11801 2nd ED, EN 50173 2nd ED, EIA/TIA-568-B.2, NF C 20730,Standard 8077 - 603.7 (Make: Legrand / Panduit - Pannet/Siemon).

Nos. 12

4.0 4 Feet : CAT6A UTP 26 AWG LSOH Patch Cord - 1 mtr - Rack End for Data Points.

Factory crimped LCS2 Patch cord in Green colour. Standard & Approval : EN 50173,

ISO/IEC 60603-7, ISO/IEC 11801 (Make: Legrand / Panduit - Pannet/Siemon).

Nos. 525

5.0 7 Feet : CAT6A UTP 26 AWG LSOH Patch Cord - 2 mtr - User End for Data Points.

Factory crimped LCS2 Patch cord in Green colour. Standard & Approval : EN 50173,

ISO/IEC 60603-7, ISO/IEC 11801 (Make: Legrand / Panduit - Pannet/Siemon).

Nos. 525

6.0 Supplying and fixing following Modular base & cover plate on existing modular metalboxes etc. as required.

a) 1 Module : Single Module Face Plate with Arteor White (Make: Legrand/Panduit -Pannet/Siemon).

Nos. 10

b) 2 Module : Dual Module Face Plate with Arteor White (Make: Legrand/ Panduit -Pannet/Siemon).

Nos. 300

Electrical BOQ 12

BOB, 27th floor, Gift City, Ahemdabad

7.0 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair(U/UTP) Cable 305 mtr per Box. Blue in colour conforming to the following standardslike ANSI/TIA 568 C.2, EN50173, IEC 11801 2nd ED, 700Mhz etc. in Cat 6 U/UTPLCS2 cable with 23AWG.

Mtrs. 32000

8.0 Supplying, installing, testing and commissioning of Cat 6 , Tool less Information outletfor Data,Voice,CCTV,Wi-Fi, & Access Control. Cat6 U/UTP built in crimping hands-free, minimum 5 times reconnection possibilities. LCS2 Toolless RJ45 Informationoutlet where insertion test (in & out) must be 2500 times (I/O) along with front sideLabel holded and transparent shutter for projection Arteor category white in colour,including front plate and anodised GI box in concealed manner of adequatesizes,including all fixing accessories.Makes : LEGRAND / PANDUIT / SIEMON

Nos. 495

9.0 Supplying, installing, testing and commissioning of 24 port Cat 6 patch panelsavailable with block of four equipped with tool less IO, Rack Mountable. 19" ModularPatch Panel, loaded CAT6 U/UTP 24 port LCS2 rack mountable to be compatible in4nos of 6 X RJ 45 Tool less connector U/UTP unit in a block.Makes : LEGRAND /PANDUIT / SIEMON

Nos. 22

10.0 Supplying, installing, testing and commissioning of following length of Cat - 6 patch

cord. 4 Feet : CAT6 UTP 23 AWG Patch Cord - 1 mtr - Rack End. Factory crimped

LCS2 Patch cord in Blue colour. Makes : LEGRAND / PANDUIT / SIEMON

Nos. 495

11.0 Supplying, installing, testing and commissioning of following length of Cat - 6 patch

cord. 7 Feet : CAT6 UTP 23 AWG Patch Cord - 2 mtr - User End.Factory crimped

LCS2 Patch cord in Blue colour. Makes : LEGRAND / PANDUIT / SIEMON

Nos. 495

12.0 Supplying and fixing following Modular base & cover plate on existing modular metalboxes etc. as required.1 or 2 Module Face Plate. Makes : LEGRAND / PANDUIT / SIEMON

Nos. 495

13.0 Supplying, installing, testing and commissioning of Cabinet. Size 2026 X 800 X 800mm (HXWXD) following accessories, Width (mm) 800, Depth (mm) 800, Approx.NetWt (kg) 150, CRCA 'D' Grade thickness (mm) 1.2, RAL 9017(Matt Black), Glass: 4mmToughened Tinted Glass Door,Injected one piece polyurethane gasket on frame,Accessories: Cooling Fan (230V A/C 90 CFM) - 4 Nos, Cable Manager Metal- 4Nos,PDU 230VAC - 1 No (12 nos. 6A/16A sockets with plugs 6A/16A - 1/1pc & MCB16A/32A -0/1 Pc), cable channel 100mm wide 42U- 2 Nos,Heavy Duty Stationaryshelf M6 screws,washer,cage nuts (nickel coated))3 Nos. Earthling Strips 150mm H -1 No, Door Lock - 1 No, Castor Wheels (with Brake) - 2 Nos, Castor Wheels (withoutBrake) - 2 Nos, Front Metal Band - 1 No. Packing: 5 ply cardboard & Inside 28 ply EPfoam. In the rack there must be maintained 1 U = 1.75 inches space. Nos. 1 etccomplete as required

Nos. 3

14.0 Supply , Installation , Testing and Commissioning of L3 Switch should have Min 24x100/1000T , Min 4 X 10 G Based SFP+ port , 2x Stacking port comprising 140 Gbpsof stacking bandwidth from day 1, Support less than 50 Millisecond convergencebased of RFC 3619./REP/G.8032 , Min Operating temp 0-50 Degree C ,Must haveCommon criteriacertification EAL3/NDcPP/NDPP, should support AVB,CE.2 and CBcertified.RPS Support . Min 196 Gbps switching backplane , Min 220 Mppsforwarding Rate .Should be upgardable to Min 2x QSFP+ port .OperatingTemperature 0-50 Degree C , Should support SyNCE E , MPLS .Auto adustable fanbased on temperture variation.Makes : Juniper / HP / Cisco / Extreme

Nos. 1

Electrical BOQ 13

BOB, 27th floor, Gift City, Ahemdabad

15.0 Supply , Installation , Testing and Commissioning of Access switch should have 24x10/100/1000T port , , should be upgradable to Min 4x 10 G based SFP+ port , 2xStacking port comprising 10 Gbps of stacking bandwidth from day 1 ,Support lessthan 50 Millisecond convergence based of RFC , Min Operating temp 0-50 Degree C,Must have Common criteriacertification EAL3/NDcPP/NDPP, should supportAVB,CE.2 and CB certified.RPS Support.Auto adustable fan based on temperturevariation.Makes : Juniper / HP / Cisco / Extreme

Nos. 18

16.0 Supply , Installation , Testing and Commissioning of Access switch should have 24x10/100/1000T port , , should be upgradable to Min 4x 10 G based SFP+ port , 2xStacking port comprising 10 Gbps of stacking bandwidth from day 1 ,Support lessthan 50 Millisecond convergence based of RFC , Min Operating temp 0-50 Degree C,Must have Common criteriacertification EAL3/NDcPP/NDPP, should supportAVB,CE.2 and CB certified.Min 370 Watt PoE/PoE+ power budget based on IEEE802.3af/IEEE 802.3at,RPS Support, Min 1GB RAM & 4GB Flash.Auto adustable fanbased on temperture variation.Makes : Juniper / HP / Cisco / Extreme

Nos. 4

17.0 OM3 6 Core Fiber Cable in PVC Conduite Supply & Laying. Mtr 350

18.0 FIBER SLIDING DRW liu 24 PORT, LC ADAPTER PLATE MM 12 PORT, BLANKS FOR LIU, FUFION SPLICE, PIGTAIL SUPPLY & FIXING Set 8

19.0 OM 3 LC Patch coard 3 Mtr Supply & Fixing. Nos. 8

21.0 500 Pair Telephone Tag Box With Krone Strip Supply & Fixing. Nos. 2

22.0 100 Pair Jelly Arm Cable Supply & Laying. Mtr. 250

TOTAL CARRIED OVER TO SUMMARY

G) TELEPHONE SYSTEM

1.0 Supply , Installation , Testing and Commissioning of KTS Telephone instrument - (NEC - SV NEC 9100 or equivalent )Makes : Cisco / NERON / Karel

Nos. 2

Electrical BOQ 14

BOB, 27th floor, Gift City, Ahemdabad

2.0 Supply , Installation , Testing and Commissioning of Telephone Instrument. (Beetel : M71 or equivalent)Makes : BEETEL /BINATONE/PANASONIC

Nos. 450

TOTAL CARRIED OVER TO SUMMARY

H) IP CCTV SYSTEM

1.0 Supply , Installation , Testing and Commissioning of 4 MP Dome Camera ,UL , CE ,FCC Certified , 1/2.8" CMOS sensor ,2.8mm to 12 mm varifocal , triple stream ,MinIllumination :0.05Lux @ (F1.2,AGC ON ), 0 Lux with IR , Shutter Speed : 1/5 ̴1/100,000 s , Video Compression : H.265 , H.264 ,frame rate 30 fps @ 3MP , InbuiltIR LED , IR distance upto 30 mtrs ,IP 66 , POE .Make s : Pelco / Honeywell/ AXIS

Nos. 12

2.0 Supply , Installation , Testing and Commissioning of 4 MP Bullet Camera ,S & G ,UL ,CE , FCC Certified , 1/2.8" CMOS sensor ,3.6 mm fixed focal , triple stream ,MinIllumination :0.05 Lux @ (F1.2, AGC ON ), 0 Lux with IR , Shutter Speed : 1/5 ̴1/100,000 s , Video Compression : H.265 , H.264 , 120 dB WDR ,frame rate 30 fps@ 3MP , Inbuilt IR LED , IR distance upto 30 mtrs ,IP 66 , POEMakes : Pelco / Honeywell / AXIS

Nos. 4

3.0 Supply , Installation , Testing and Commissioning of 16 Channel NVR , 2 SATA ports, each SATA capacity of upto 6 TB , Recording Bandwidth 200 Mbps , 1 X HDMI , 1 XVGA , Alarm : 16ch in / 1ch out , 1 X RJ45 port , 1x3.0 USB for backup / upgrade, 2x2.0 USB for mouse , Smart Phone support : iOS, Android.Makes : Pelco / Honeywell / AXIS

Nos. 1

4.0 Supply , Installation , Testing and Commissioning of 6TB Surviellance Hard Disk. Nos. 2

5.0 Supply , Installation , Testing and Commissioning of Full HD 42" LED ProfessionalDisplay Panel.

Nos. 1

6.0 Supply , Installation , Testing and Commissioning of 24 port L2 Managed switchhaving port density 24 Nos. of 10M/100M/1G RJ45 Port POE/POE+ ports , 4 Nos. of1G/10G SFP+ Port , 1X console port , Available POE power 370 W , 128 Gbpsswitching bandwidth , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN, port based VLAN , MAC based VLAN , IP subnet based VLAN . Support IEEE802.3ad LACP . L3 features - static routing , DHCP server , Device Managementsystem - topology view , floor view , map view , dashboard , traffic monitoring , cablediagnostics.CE,FCC certified.Makes : Juniper / HP / Cisco / Extreme

Nos. 1

TOTAL CARRIED OVER TO SUMMARY

Electrical BOQ 15

BOB, 27th floor, Gift City, Ahemdabad

I) ACCESS CONTROL SYSTEM

1.0 ACS Controller:Supply, installing, testing and commissioning of Standalone Controller :- 2.4-inch TFTcolor screen and Touch keys, Ultra thin and elegant design With Builtin WifiFingerprint Identification Fingerprint Capacity: 3,000 Log Capacity: 30,000Communication:TCP/IP,RS232/485,USB Host Access Control Interface for electriclock,door sensor,alarm,exit button and door bell. Wiegand input&output

Nos. 10

2.0 Exit Reader :- Finger Print Reader Weather Proof Read Fingerprint and Proximity card Communication: RS485 with inBIO controller or Fingerprint devices DIP switch for RS485 address

Nos. 10

3.0 RFID Cards :- ISO RFID Cards Nos. 500

4.0 Bracket :- U Bracket For Glass Door Nos. 5

5.0 Bracket :- L Bracket For Locks Nos. 5

6.0 Lock :- Single Electromagnetic Locks - 600 lbs as per specifications Nos. 10

7.0 Egress :- No Touch Exit SensorExit No Touch Sensor-Stainless steel Nos. 5

8.0 Enrollment Unit :- Finger print Enrollment device, is a stable and excellent fingerprint reader. The device can capture fingerprint image and upload to the PC by USB interface. High-performance, maintenance-free optical fingerprint sensor.

Nos. 1

9.0 Software :- Web Base ACS & Time-attendance software Nos. 1

10.0 Supply, installing, testing and commissioning of Emergency Break Glass withrequired accessories as per technical specifications

Nos. 10

11.0 Cables: Supply, installing, testing and commissioning of :All the cables Should be weatherproof, outdoor grade & as per BIS standard.

11.a 8 core 20 to 22 AWG, 6 or 8-conductor, stranded, shielded armoured cable withrequired accessories

Mtrs. 250

11.b 6 core, 2-conductor 20 to 22 AWG, stranded, shielded armoured cable with requiredaccessories

Mtrs. 75

11.c 4 core, 2-conductor 20 to 22 AWG, stranded, shielded armoured cable with requiredaccessories

Mtrs. 150

TOTAL CARRIED OVER TO SUMMARY

Electrical BOQ 16

BOB, 27th floor, Gift City, Ahemdabad

J) SENSOR SYSTEM

1.0 Supplying of Digital PIR LightSpot HD Switching Sensors Ceiling Mount 360 degree. High Sensitivity Range 10 m Dia at height of 2.5 meter ( 7 m dia Micro Sensitivity 3 m macro) and . Current Capacity 10A. Digital Remote IR based Commissioning with hand held programmer for following programmable features: Absence mode, OFF delay time 10 Sec - 96 hrs, photocell and power up (status of luminaires when power is applied). It shall have provision to manually override luminary ON/OFF status using hand held remote control, similar to Honeywell LS3200R or equivalent

Nos 15

TOTAL CARRIED OVER TO SUMMARY

K) TV SYSTEM

1.0 Supply , Installation , Testing and Commissioning of Full HD 55" LED ProfessionalDisplay Panel Contras Ratio -4000:1, H/W - Tempreture Sensor, Pivot Display, ClockBattery (168 hrs Clock keeping) Built in speaker ( 10W 2ch) IP5x, Wifi S/W - Autosource Switching & Recovery, LFD Home UI, Button lock, hot key option , Plug & Playinitial Setting. ( Equivalent to Samsung QB55N )

Nos. 6

2.0 Wiring for TV point with RG-6 TV coaxial cable in ExistingPVC conduit includingsupply of all metarials complete as required.

Mtrs 150

3.0 Supply & fixing the following sizes of PVC conduit in recessed or on surface of wall .

False ceiling including cutting the wall and making good the same as required.

a) 25 mm dia Mtrs 150

4.0 Supply & laying of RG-11 TV co-axial cable for cable TV system in 25 mm dia PVCconduit pipe in recess or on surface of wall including cutting the chases as makinggood the damage etc as required. (For Vertical & Horizontal runs)

Mtrs 75

5.0 Supply & fixing of co-axial type TV socket in zinc chromate passivated M.S. Box &Moduler plate including making connections etc. complete as required.

Nos. 6

6.0 Supply & fixing the following type of splitter box / Tape Off box in recess in wall orceiling or on surface etc as required.

a) 2 way splitter / Tape Off box Nos. 2b) 4 way splitter / Tape Off box Nos. 1

TOTAL CARRIED OVER TO SUMMARY

Electrical BOQ 17

BOB, 27th floor, Gift City, Ahemdabad

L)LIGHTING FIXTURES (MAKE : PHILPS/ WIPRO / CROMPTON / HALONIX)

Supply, storing, Installation, testing, & commissioning of All type of Recessed /Surface mounted Lighting Fixtures (as approved by client/architect) including all fixinghardwares complete as required (Light fittings shall be supplied by owner as free

issue item )

1.0 Supplying, storing, unpacking, assembling, Installation, testing, & commissioning of

LED STRIP Light (as approved by client/architect) including all fixing hardwares

complete as required (Light fittings shall be supplied by owner as free issue item )

Mtr. 100

2.0 Supply, installation, testing & commissioning of 48/36" ceiling/wall fans complete withall accessories such as blades, canopy etc. including wiring the down rod with 3 x 1.5sq mm FRLS PVC insulated multistranded copper conductor wires and earthing thefans etc. complete as required.

Nos. 12

3.0 Supply, installation, installation, testing & commissioning of 12/9" exhaust fans on

existing opening in wall including all fixing hardware, louvers, shutters etc.

Connection with 3 x 1.5 Sqmm FRLS PVC insulated multistranded copper conductor

wire from the socket outlet to the fan earthing etc. complete as required.

Nos. 6

4.0 Supply & installation of self illuminated Exit / Fire Exit Signs boards (Glolite/Prolitemake) hung from ceiling or on wall as per site conditions complete with allaccessories etc. as required

a) Two Sided 11" x 4" Nos. 3

b) One Sided 11" x 4" Nos. 3

5.0 Supply, Installation, Testing and Commissioning of following LED Lighting Fixture

a) 30W 2x2 - Supply, Installation, Testing and Commissioning of 30W, Recess mountedIP20 LED 2x2 Feet luminaire having greater than 3600 lm system output-120 lm/wsystem efficacy. Luminaire shall be made up of CRCA powder coated housing. Drivershall be fixed inside the housing only, no separate drier with wiring will be acceptable.Luminaire shall have Optical Grade High Efficiency Translucent Optical compartmentfor very high efficiency with minimum glare. Optical compartment shall have UniqueHET diffuser for wider and uniform distribution. LM 80-08 compliant, ANSI rated LEDsfrom reputed makes such as Nichia, Japan / Cree, USA / Citizen Japan shouldbe provided. Luminaire shall have CCT 5700K ±350K. Luminaire shall use multipleLEDs of less than 0.5W Class for better diffusion and heat management. The LEDshall be compliant with LM80-08 standard with Useful L70 life (L70 B10 or L70 B50not acceptable) of 50000 Hrs (Complete LM 80 test report for LED should besubmitted). The LEDs used in luminaire should be McAdam Step 5 standard RatedLED with CRI of Minimum 80. LEDs used must be tested as per EN62471 forPhotobiological Safety of humans and Report of the same from LED Manufacturershall be submitted. Driver shall be multi stage Constant Current Constant Voltagewith voltage range of 150-270V AC. Output voltage of driver should be complied toSafety Extra Low Voltage norms not exceeding 60V DC only. Driver Power factor shall be 0.95 and above and THD shall be less than 10%. ( Phillips, Wipro, Crompton)

Nos. 250

Electrical BOQ 18

BOB, 27th floor, Gift City, Ahemdabad

b)

12W Downlighter -Supply, Installation, Testing and Commissioning of 12W, Recessmounted IP20 LED Circular Downlighter luminaire having greater than 1200 lmsystem output-100 lm/w system efficacy.. Luminaire shall be made up of Die Castpowder coated housing with integral Fins. Driver shall be fixed with housing of thefixtures only, no separate driver with wiring will be acceptable. Luminaire shall haveOptical Grade High Efficiency Translucent Optical compartment for very highefficiency with minimum glare. Optical compartment shall have Unique HET diffuserfor wider and uniform distribution. LM 80-08 compliant, ANSI rated LEDs from reputedmakes such as Nichia, Japan / Cree, USA / Citizen Japan should be provided.Luminaire shall have CCT 5700K ±350K. Luminaire shall use multiple LEDs of lessthan 0.5W Class for better diffusion and heat management. The LED shall becompliant with LM80-08 standard with Useful L70 life (L70 B10 or L70 B50 notacceptable) of 50000 Hrs (Complete LM 80 test report for LED should besubmitted). The LEDs used in luminaire should be McAdam Step 5 standard RatedLED with CRI of Minimum 80. LEDs used must be tested as per EN62471 forPhotobiological Safety of humans and Report of the same from LED Manufacturershall be submitted. Driver shall be multi stage Constant Current Constant Voltagewith voltage range of 150-270V AC. Output voltage of driver should be complied toSafety Extra Low Voltage norms not exceeding 60V DC only. Driver Power factor shall be 0.95 and above and THD shall be less than 10%.( Phillips, Wipro, Crompton)

Nos. 300

c) Supply, Installation, Testing and Commissioning of LED 4ft. 18 Watt ( Equivalent to.Wipro cat No D53206500K )

Nos. 10

d) Supply, Installation, Testing and Commissioning of Hanging Light 40 Watt (Equivalent to Wipro cat No. LM 34-501-xxx-57-DD)

Nos. 7

e) Supply, Installation, Testing and Commissioning of 5 watt / mt. 50/50 LED Strip LightWith Driver (Equivalent to Wipro cat No. D45040 4000K )

Mtr. 100

f) Supply, Installation, Testing and Commissioning of 9Watt Spot Light ( Equivalent toWipro cat No D 120940)

Nos. 70

g) Supply, Installation, Testing and Commissioning of 20W Wall Mounted DecorativeLight Phillips 31425 Muziris Singale head Wall Light ( Equivalent to Phillips BronzeE27 Base )

Nos. 30

TOTAL CARRIED OVER TO SUMMARY

Electrical BOQ 19

BOB, 27th floor, Gift City, Ahemdabad

M) FIRE ALARM SYSTEMS

H

FIRE DETECTION SYSTEM (ANALOGUE ADDRESSABLE) Make: Honeywell/BOSCH/SIEMENS/UTC/Ravel Note:For Fire Alarm System (FAS) Standards : NFPA 72/IS 11360-1985/IS22189/IS-2175/EN54 Approvals: VdS/ UL/ LPCB or equivalentNoteAll A.C Unit and Exit door shall be integrated with fire panel so that in case of fire signal, all shall be switched OFF.2 Layer For Ceiling and Above False Ceiling

1

SITC of Addressable Multi Sensor - Heat Cum Smoke detector with base with address setting. Dual LED’s for 360° visibility. Sleek low-profile housing design. Regular 100mm base. IP Rating : IP - 42. Approval: UL Listed Nos 140

2SITC of Addressable Heat detector with base with address setting. Dual LED’s for 360° visibility. Sleek low-profile housing design. Regular 100mm base. IP Rating : IP - 42. Approval: UL Listed

Nos 1

Electrical BOQ 20

BOB, 27th floor, Gift City, Ahemdabad

3SITC of Addressable type Horn / Strobe wall mounted type rated at 90 dBA @ 1m for Audible annunciation and 15cd minimum flashing at 1 Hz for visual indication - Approval: UL Listed

Nos 8

4SITC of Addressable Manual Pull Stating - Single Action - with back box with Break Glass with Back Box for Manual Pull Station - Approval: UL Listed Nos 8

5 SITC of Fault isolator Module capable of monitoring shorted loop circuit Nos 20

6 SITC of Addressable Control Relay Module for monitoring the field devices. Approval: UL Listed Nos 10

7 SITC of Addressable Monitor Module for monitoring the field devices. Approval: UL Listed Nos 2

8 Supply, installation, connecting, testing and commissioning of Response indicator. Nos 57

Electrical BOQ 21

BOB, 27th floor, Gift City, Ahemdabad

9

SITC of Analogue Addressable Fire Alarm Control panel shall be Networkable with switch mode power supply, battery back up and charger .The panel shall have 4 loops as capacity with Builtin installed loop cards and with More than 250 devices per loop in any combination. The panel shall consisting with 160 character LCD display, Touch keys. Shall be networkable by RS 485 or TCP/IP , repeater/Mimic connectivity. USB - 2.0 for PC Interface. Degraded redundancy operating mode when the main CPU fails. UL Listed Along with Battery Backup up

Set 1

10Providing and fixing in position 1.2mm thick PVC outlet boxes for housing smoke detectors/heat detectors including providing 3 mm thick hylam sheet cover as required

Nos 12

a. 75mm x 75mm x 75mm Nos 12

11

Supply & laying of following grade with copper conductor armoured FIRE SURVIVAL cable with (EPR) Ethylene Propylene rubber insulation as per IEC-60502:2004 Part-1 (Armoured), Retain circuit integrity as per BS 6387 C.W.Z (armoured), BS- 8491:2008, BS 8434-2: 2009 (armoured), (Resistance to fire at 950º C for 3 hours), as per specifications in cable trays, clamped including anchor fastners to wall with suitable clamps, saddles fixing bolts,2 cable glands for each detector back box, complete in all respect as required as per specifications.(Red Colour)

a. 2 core x 1.5 sq. mm RM 1500

TOTAL CARRIED OVER TO SUMMARY

N) PA SYSTEM FOR FIRE ALARM

1.0Supply, Installation, Testing & Commissioning of 2 Way Communication Fire Fighter'sTelephone Jack. Nos. 2

2.0Supply, Installation, Testing & Commissioning of 2 Way Communication Fire Fighter'sHandset Nos. 2

3.0

SITC of followings with commnication cable and accessories as required for system.Voice Zone Controller as required for system. suitable Zone selector with microphone including keypad as required for system. Router as required for system.System compressive of above as required

NOS. 1

4.0SITC of Pagging microphone Min 6 Zone for interface with controller includingcommunication cable and all accessories. NOS. 2

5.0

SITC of rack mounted dual Channel Power Amplifier capable of delivering 300 WRMS power output or 480 W RMS burst output; complete with 100 V Line MatchingTransformer, built-in fan for temperature control, Distortion typically 0.03% @ 1 KHz,Hum and Noise 90 dB below rated output selection facility,provision for hookup withFire Alarm Panel, complete with connections and required circuitry

NOS. 1

6.0 Supply, Installation, Testing And Commissioning of Wireless microphone NOS. 4

7.0Supply, Installation, Testing And Commissioning of Ceiling loudspeaker, 6/3W,Frequency response of 110 Hz - 18 kHz. NOS. 50

8.0Supply, Installation, Testing And Commissioning of wall mount loudspeaker, 6/3W,Frequency response of 200Hz - 20KHz NOS. 10

9.0Supply, Installation, Testing and Commissioning of 2 Core X 1 Sq.mm flexible cable.

MTRS 850

10.0Supply, installation, testing and commissioning of 25mm pvc conduits for laying ofabove cable. MTRS 850

11.0

Supply, installation, testing and commissioning of 18U (600 x 600) floor mount closedrack with front glass door, fan tray on top, perforated rear doors, keyboard tray withshelf. Casters & 2 nos vertical power strip with std. accessories. NOS 1

O) EARTHING

1.0 Supply and laying 1 x 16sqmm copper wire for UPS/Server Mtrs 200

2.0 Supplying and laying of 8 SWG G.I. Wire on surface / recess as required. Mtrs 400

TOTAL CARRIED OVER TO SUMMARY

Electrical BOQ 22

BOB, 27th floor, Gift City, Ahemdabad

3.0 25x3 Hot Dip Gi strip Supply & Laying. Mtrs 250

4.0 25x3 Cu Strip Supply & Fixing. Mtrs 50

P) FIRE SUPPRESSION SYSTEM

1.0Supply, Installation, testing & Commissioning of UL Listed 80 Ltr Seamless Cylinderand Valve assembly.

Nos. 1

2.0 Supply of Novec 1230 Fluid factory filled. Kg. 80

3.0Supply, Installation, testing & Commissioning of Nozzle Brass- 360 / 180 Degree.

Nos. 3

4.0Supply , Installation , Testing & Commisssiong of Conventional Smoke detecors.

Nos. 4

5.0 Supply , Installation , Testing & Commisssiong of Control Relay module. Nos. 1

6.0Providing, fixing, testing and commissioning of Manual Release & Abort Station.

Nos. 1

7.0 Providing, fixing, testing and commissioning of addressable monitor module. Nos. 2

8.0 Providing, fixing, testing and commissioning of Hooter. Nos. 2

9.0 Supply , Installation , Testing & Commisssiong of Control Release module. Nos. 1

Q) VIDEO SYSTEM1.0 Motorized screen (Product code AMS)

120" Diagnal Motorised Screen set 1

2.0 Beyond Full HD resolutionWhite and colour brightness of 4,000 lumensLaser Light Source20000Hours Maintenance free use**Dual Screen seamless interactivityWireless Projection and Miracast® Finger Touch InteractiveUltra Short Throw 80” screen @ 47cm

set 1

3.0 Projector Mount Kit set 14.0 HDMI cable 15 mtr. Length set 125.0 1.5 sq mm x 2 core shilded flexibale cable with PVC conduite supply & Fixing. meter 1006.0 Pop Up Box With 1 Nos HDMI , 1 Nos USB, 1 Nos plug point , 1 Nos DATA Point, 1

Nos Voice ( Legrand Cat No :- 654003 & above items ) set 6

7.0 SITC of Subwoofer Cable - 1 sq mm x 2 core shilded flexibale in PVC Conduite.set 1

8 Rodent protection system

Supply, Instllation, testing and commissioning of roent protection system for server and switch rooms. MAKE : C system / Maser / equivalent set 8

TOTAL CARRIED OVER TO SUMMARY

TOTAL CARRIED OVER TO SUMMARY

TOTAL CARRIED OVER TO SUMMARY

TOTAL CARRIED OVER TO SUMMARY

Electrical BOQ 23