5
Sheet Title: Scale: 1:100 Date: April, 2015 Project # 2015-38 Project: J o n a t h a n L o s e e L t d. L a n d s c a p e A r c h i t e c t u r e #102 - 1661 W. 2nd Ave. Vancouver, B.C. V6J 1H3 Ph: 604-669-1003 E-mail: info@jonathanlosee.com Mar 30 , 2016 For Review April 1, 2016 RZ/DP Submission L-0 Revisions : Sheet Title: Scale: 1:100 Date: Project No. 2016-22 L-1 Project: April 7 17 For Rezoning J o n a t h a n L o s e e L t d. L a n d s c a p e A r c h i t e c t u r e #102 - 1661 W. 2nd Ave. Vancouver, B.C. V6J 1H3 Ph: 604-669-1003 E-mail: info@jonathanlosee.com x x x x x x x x Level 1 FFE: 89'-6" Basement: 79'-0" DAVIE STREET NICOLA STREET LANE EXISTING BUILDING (TO REMAIN IN SAME LOCATION) PROPOSED NEW TOWNHOMES CONCRETE SIDEWALK PROPOSED NEW ADDITION EXISTING GAS METER SETBACK SETBACK REFUSE DN DN SETBACK SETBACK SETBACK SETBACK (HRA) ADJACENT 3-STOREY RESIDENTIAL BUILDING PENDRELL STREET) D.G. 86.00' D.G. 84.95' D.G. 84.41' D.G. 86.23' D.G. 86.85' D.G. 87.42' EXISTING DRIVEWAY, RE-PAVED AND USED AS PEDESTRIAN WALWAY FIRE HYDRANT: SW CORNER OF DAVIE ST AND NICOLA ST. APPROXIMATELY 29 M FROM CORNER OF PROPERTY LINE. MODIFIED WALKWAY RE-PAVED WALKWAY COMMON WALKWAY EXISTING MONUMENT SIGN PROPOSED NEW PATIO AT BASEMENT LEVEL, TYPICAL. EXISTING SUMP TO BE LOWERED / RELOCATED AS REQUIRED, NOT TO INTERFERE WITH NEW PATIO PRESERVED LANDSCAPING SHOWN IN GREY, TYPICAL SETBACK PMT EL. 83.50' PROPOSED TRANSFORMER UP PROPERTY LINE: 198.00' PROPERTY LINE: 197.97' PROPERTY LINE: 131.02' PROPERTY LINE: 131.00' MAIN ENTRY SECOND ENTRY MAIN ENTRY SECOND ENTRY SECOND ENTRY WALKWAY EXISTING GAS VALVE TELUS MANHOLE EXISTING MANHOLES EXISTNG CONCRETE CURB EXISTING CONCRETE APRON NEW SIDEWALK AND LANDSCAPING TO MATCH ADJACENT SURFACES EXISTING UTILITY POLE EXISTING CATCH BASIN EXISTING LAMP POST EXISTING METAL FENCE WITH BRICK POSTS, TO BE REFINISHED AND REPAINTED AS NEEDED. PORTE COCHERE LINE OF ROOF OVERHANG ABOVE, TYPICAL EXISTING WOOD FENCE NEW WINDOW WELL NEW WINDOW WELL DN INFILL WITH GRAVEL & TOPSOIL AS NEEDED TO ENSURE FLUSH WITH EDGE OF RAMP DN B.G. 83.40' (25.42 m) B.G. 84.24' (25.68 m) B.G. 85.55' (26.08 m) B.G. 87.12' (26.55 m) B.G. 87.86' (26.78 m) B.G. 88.38' (26.94 m) B.G. 88.59' (27 m) B.G. 89.11' (27.16 m) B.G. 89.11' (27.16 m) B.G. 87.97' (26.81 m) B.G. 86.05' (26.23 m) B.G. 83.55' (25.47 m) B.G. 81.02' (24.7 m) PLANTING LANDSCAPING PLANTING LANDSCAPING LANDSCAPING PLANTING D.G. 88.50' D.G. 88.70' NEW SIDEWALK AND LANDSCAPING TO MATCH ADJACENT SURFACES B.G. 88.67' (27.03 m) BASEMENT PATIO BELOW BASEMENT PATIO BELOW BASEMENT PATIO BELOW CLASS B BICYCLE PARKING NEW BOLLARDS EL. 84.54' EL. 84.68' PATIO PATIO PATIO PATIO ENTRY TO BASEMENT MAIN ENTRY MAIN ENTRY MAIN ENTRY SECOND ENTRY SECOND ENTRY SECOND ENTRY EL. 89.50' LANDSCAPING LANDSCAPING EXISTING LANDSCAPING, TO BE RETAINED C S B B M S 2 S 2 S I E T Existing Tree to be transplanted NOTE: The tree protection barriers must be built and inspected before the building permits can be issued. Please call the building inspector at 311 or at 604 873-7601 and request a tree barrier inspection at least 48 hours in advance of the building permit. All tree protection on street trees to be set back 300 mm from the edge of sidewalk to allow clear circulation, and 600 mm from the back of curb to allow door opening. Existing Tree to be transplanted Tree protection fence around this entire area to protect existing lawn and shrub beds. Maintain during construction. Tree protection fence around this entire area to protect existing lawn and shrub beds. Maintain during construction. All work within tree protection zone to be done under the supervision of the project arborist. All work within tree protection zone to be done under the supervision of the project arborist. All work within tree protection zone to be done under the supervision of the project arborist. Planting within the TPZ to be done using low impact soil detail. All off site tree protection to be set back 300 mm from the sidewalk and 600 mm from the front of curb to allow for circulation. All off site tree protection to be set back 300 mm from the sidewalk and 600 mm from the front of curb to allow for circulation. 5.5 m 5.5 m 3.0 m 4.0 m 2.0 m 4.0 m 1.5 m 1.5 m 2.5 m 1.5 m 1.5 m 0.6 m 0.3 m 0.3 m 0.6 m 2.5 m 0.3 m 0.6 m 1.5 m 0.3 m 0.6 m 1.5 m 0.3 m 0.6 m 1.5 m 0.3 m 0.6 m 1.5 m 0.3 m 0.6 m Existing tree to be retained Existing trees to be transplanted Tree Protection Fencing As per Arborist Report, and Detail 1/L-3 x Existing tree to be Removed Existing planting- hedges Existing planting- garden beds 2.0 m 0.3 m 0.6 m Transplant and store existing Rhododendrons for reuse on site L-0 EXISTING TREE NOTES City of Vancouver Engineering Department Guidelines for the Protection of Boulevard Trees Boulevard trees adjacent to construction sites must be protected (including those of less than 20 cm diameter). Boulevard trees must not be pruned without prior approval of the Park Board. Call 327-2119 for information. Barrier fencing used for tree protection must: Allow for free and clear passage of pedestrians on the sidewalk and adjacent portion of boulevard; provide for clear visibility of fire hydrants, driveway access, crosswalks, etc. ("see-through" fencing should be used.); be 0.6k m or more from the curb to provide for the opening of car doors; and, be 0.3 m or more from the edge of any sidewalk located within a grass boulevard. Note: These setbacks also reduce the possibility of interference with underground utilities when staking fences in place.

Boulevard trees adjacent to construction sites must berezoning.vancouver.ca/.../documents/15-LandscapePlan.pdf · Project # 2015-38 Project: ... LAMP POST EXISTING METAL FENCE WITH

  • Upload
    lylien

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Boulevard trees adjacent to construction sites must berezoning.vancouver.ca/.../documents/15-LandscapePlan.pdf · Project # 2015-38 Project: ... LAMP POST EXISTING METAL FENCE WITH

Sheet Title:

Scale: 1:100Date: April, 2015Project # 2015-38

Project:

J o n a t h a n L o s e e L t d.L a n d s c a p e A r c h i t e c t u r e

#102 - 1661 W. 2nd Ave.Vancouver, B.C. V6J 1H3

Ph: 604-669-1003E-mail: [email protected]

Mar 30 , 2016 For Review

April 1, 2016 RZ/DP Submission

L-0

Revisions :

Sheet Title:

Scale:1:100

Date:

Project No.2016-22

L-1

Project:

April 7 17 For Rezoning

J o n a t h a n L o s e e L t d.L a n d s c a p e A r c h i t e c t u r e

#102 - 1661 W. 2nd Ave.Vancouver, B.C. V6J 1H3

Ph: 604-669-1003E-mail: [email protected]

x

x

x

x

x

xx

x

Level 1 FFE: 89'-6"Basement: 79'-0"

DAVIE STREET

NIC

OLA

STR

EE

T

LANE

EXISTING BUILDING(TO REMAIN IN SAME LOCATION)

PROPOSED NEWTOWNHOMES

CO

NC

RE

TE S

IDE

WA

LK

PROPOSEDNEW

ADDITION

EXISTING GAS METER

SE

TBA

CK

SE

TBA

CK

REFUSE

DN DN

SETBACK

SETBACK

SE

TBA

CK

SE

TBA

CK

(HR

A)

ADJACENT3-STOREY

RESIDENTIALBUILDING

PARKADEENTRY POINT(1500PENDRELLSTREET)

D.G. 86.00'

D.G. 84.95'

D.G. 84.41'

D.G. 86.23'

D.G. 86.85'

D.G. 87.42'

EXISTING DRIVEWAY,RE-PAVED AND USED ASPEDESTRIAN WALWAY

FIRE HYDRANT:SW CORNER OF DAVIE

ST AND NICOLA ST.APPROXIMATELY 29 M

FROM CORNER OFPROPERTY LINE.

MODIFIEDWALKWAY

RE-PAVEDWALKWAY

COMMONWALKWAY

EXISTING MONUMENT SIGN

PROPOSED NEWPATIO AT

BASEMENTLEVEL, TYPICAL.

EXISTING SUMP TO BELOWERED / RELOCATEDAS REQUIRED, NOT TOINTERFERE WITH NEWPATIO

PRESERVEDLANDSCAPING SHOWNIN GREY, TYPICAL

SETBACK

PMT

EL. 83.50'

PROPOSEDTRANSFORMER

UP

PROPERTY LINE: 198.00'

PROPERTY LINE: 197.97'

PRO

PER

TY L

INE:

131

.02'

PRO

PER

TY L

INE:

131

.00'

MAIN ENTRY

SECONDENTRY

MAINENTRY

SECONDENTRY

SECONDENTRYWALKWAY

EXISTING GAS VALVE

EXISTINGUTILITY POLE,TYPICAL

TELUS MANHOLE

EXISTING MANHOLES

EXISTNG CONCRETE CURB

EXISTING CONCRETE APRON

NEW SIDEWALK ANDLANDSCAPING TO MATCH

ADJACENT SURFACES

EXISTINGUTILITYPOLE

EXISTINGCATCHBASIN

EXISTINGLAMP POST

EXISTING METALFENCE WITHBRICK POSTS, TOBE REFINISHEDAND REPAINTEDAS NEEDED.

PORTE COCHERELINE OF ROOFOVERHANGABOVE, TYPICAL

EXISTINGWOODFENCE

NEW WINDOW WELL

NEW WINDOW WELL

DN

INFILL WITHGRAVEL &

TOPSOIL ASNEEDED TO

ENSURE FLUSHWITH EDGE OF

RAMP

DN

B.G. 83.40'

(25.42 m)

B.G. 84.24'

(25.68 m)

B.G. 85.55'

(26.08 m)

B.G. 87.12'

(26.55 m)

B.G. 87.86'

(26.78 m)

B.G. 88.38'

(26.94 m)

B.G. 88.59'(27 m)

B.G. 8

9.11'

(27.16

m)

B.G. 8

9.11'

(27.16

m)

B.G. 87.97'

(26.81 m)

B.G. 86.05'

(26.23 m)

B.G. 8

3.55'

(25.47

m)

B.G. 8

1.02'

(24.7

m)

PLA

NTI

NG

LANDSCAPING

PLANTING

LANDSCAPING

LAN

DS

CA

PIN

G

PLANTING

D.G. 88.50'

D.G. 88.70'

NEW SIDEWALK ANDLANDSCAPING TOMATCH ADJACENT

SURFACES

B.G. 8

8.67'

(27.03

m)

BASEMENTPATIO

BELOW

BASEMENTPATIO BELOW

BASEMENTPATIO

BELOW

CLASS BBICYCLEPARKING

NEW BOLLARDS

EL. 84.54'

EL. 84.68'

PATIO

PATIOPATIO PATIO

ENTRY TOBASEMENT

MAINENTRY

MAINENTRY

MAINENTRY

SECONDENTRY

SECONDENTRY

SECONDENTRY

EL. 89.50'

LAN

DS

CA

PIN

G

LANDSCAPING

EXISTINGLANDSCAPING, TO

BE RETAINED

PLAN 92

ZONING:COMPREHENSIVE DEVELOPMENTCD-1 (248)

SURVEY INFORMATION:BASED ON SURVEY INFORMATIONBY HOBBS, WINTER &MACDONALD, B.C. LANDSURVEYORS, DATED: FEBRUARY25, 2016

SITE AREA:2,409.65 m?

SITE COVERAGE:INFILL:

EXISTING:

TOTAL:

Existing Tree to be transplanted

NOTE: The tree protection barriers must be built and inspected before the building permits can be issued. Please call the building inspector at 311 or at 604 873-7601 and request a tree barrier inspection at least 48 hours in advance of the building permit.

All tree protection on street trees to be set back 300 mm from the edge of sidewalk to allow clear circulation, and 600 mm from the back of curb to allow door opening.

Existing Tree to be transplanted

Tree protection fence around this entire area to protect existing lawn and shrub beds. Maintain during construction.

Tree protection fence around this entire area to protect existing lawn and shrub beds. Maintain during construction.

All work within tree protection zone to be done under the supervision of the project arborist.

All work within tree protection zone to be done under the supervision of the project arborist.

All work within tree protection zone to be done under the supervision of the project arborist. Planting within the TPZ to be done using low impact soil detail.

All off site tree protection to be set back 300 mm from the sidewalk and 600 mm from the front of curb to allow for circulation.

All off site tree protection to be set back 300 mm from the sidewalk and 600 mm from the front of curb to allow for circulation.

5.5

m

5.5

m

3.0

m

4.0 m

2.0

m

4.0

m

1.5 m

1.5 m

2.5

m1.

5 m

1.5

m

0.6 m

0.3 m

0.3 m0.6 m

2.5 m

0.3

m

0.6

m

1.5 m

0.3

m

0.6

m

1.5 m

0.3

m

0.6

m

1.5 m

0.3

m

0.6

m

1.5 m

0.3 m

0.6 m

Existing tree to be retained

Existing trees to be transplanted

Tree Protection FencingAs per Arborist Report, and Detail 1/L-3

x Existing tree to be Removed

Existing planting- hedges

Existing planting- garden beds

2.0

m

0.3 m

0.6 m

Transplant and store existing Rhododendrons for reuse on site

L-0

EXISTING TREE NOTES

City of Vancouver Engineering Department Guidelines for the Protection of Boulevard Trees

Boulevard trees adjacent to construction sites must be protected (including those of less than 20 cm diameter). Boulevard trees must not be pruned without prior approval of the Park Board. Call 327-2119 for information.

Barrier fencing used for tree protection must:

• Allow for free and clear passage of pedestrians on the sidewalk and adjacent portion of boulevard;

• provide for clear visibility of fire hydrants, driveway access, crosswalks, etc. ("see-through" fencing should be used.);

• be 0.6k m or more from the curb to provide for the opening of car doors; and,

• be 0.3 m or more from the edge of any sidewalk located within a grass boulevard.

Note: These setbacks also reduce the possibility of interference with underground utilities when staking fences in place.

Page 2: Boulevard trees adjacent to construction sites must berezoning.vancouver.ca/.../documents/15-LandscapePlan.pdf · Project # 2015-38 Project: ... LAMP POST EXISTING METAL FENCE WITH

Level 1 FFE: 89'-6"Basement: 79'-0"

DAVIE STREET

NIC

OLA

STR

EE

T

LANE

EXISTING BUILDING(TO REMAIN IN SAME LOCATION)

PROPOSED NEWTOWNHOMES

CO

NC

RE

TE S

IDE

WA

LK

PROPOSEDNEW

ADDITION

EXISTING GAS METER

SE

TBA

CK

SE

TBA

CK

REFUSE

DN DN

SETBACK

SETBACK

SE

TBA

CK

SE

TBA

CK

(HR

A)

ADJACENT3-STOREY

RESIDENTIALBUILDING

PARKADEENTRY POINT(1500PENDRELLSTREET)

D.G. 86.00'

D.G. 84.95'

D.G. 84.41'

D.G. 86.23'

D.G. 86.85'

D.G. 87.42'

EXISTING DRIVEWAY,RE-PAVED AND USED ASPEDESTRIAN WALWAY

FIRE HYDRANT:SW CORNER OF DAVIE

ST AND NICOLA ST.APPROXIMATELY 29 M

FROM CORNER OFPROPERTY LINE.

MODIFIEDWALKWAY

RE-PAVEDWALKWAY

COMMONWALKWAY

EXISTING MONUMENT SIGN

PROPOSED NEWPATIO AT

BASEMENTLEVEL, TYPICAL.

EXISTING SUMP TO BELOWERED / RELOCATEDAS REQUIRED, NOT TOINTERFERE WITH NEWPATIO

PRESERVEDLANDSCAPING SHOWNIN GREY, TYPICAL

SETBACK

PMT

EL. 83.50'

PROPOSEDTRANSFORMER

UP

PROPERTY LINE: 198.00'

PROPERTY LINE: 197.97'

PRO

PER

TY L

INE:

131

.02'

PRO

PER

TY L

INE:

131

.00'

MAIN ENTRY

SECONDENTRY

MAINENTRY

SECONDENTRY

SECONDENTRYWALKWAY

EXISTING GAS VALVE

EXISTINGUTILITY POLE,TYPICAL

TELUS MANHOLE

EXISTING MANHOLES

EXISTNG CONCRETE CURB

EXISTING CONCRETE APRON

NEW SIDEWALK ANDLANDSCAPING TO MATCH

ADJACENT SURFACES

EXISTINGUTILITYPOLE

EXISTINGCATCHBASIN

EXISTINGLAMP POST

EXISTING METALFENCE WITHBRICK POSTS, TOBE REFINISHEDAND REPAINTEDAS NEEDED.

PORTE COCHERELINE OF ROOFOVERHANGABOVE, TYPICAL

EXISTINGWOODFENCE

NEW WINDOW WELL

NEW WINDOW WELL

DN

INFILL WITHGRAVEL &

TOPSOIL ASNEEDED TO

ENSURE FLUSHWITH EDGE OF

RAMP

DN

B.G. 83.40'

(25.42 m)

B.G. 84.24'

(25.68 m)

B.G. 85.55'

(26.08 m)

B.G. 87.12'

(26.55 m)

B.G. 87.86'

(26.78 m)

B.G. 88.38'

(26.94 m)

B.G. 88.59'(27 m)

B.G. 8

9.11'

(27.16

m)

B.G. 8

9.11'

(27.16

m)

B.G. 87.97'

(26.81 m)

B.G. 86.05'

(26.23 m)

B.G. 8

3.55'

(25.47

m)

B.G. 8

1.02'

(24.7

m)

PLA

NTI

NG

LANDSCAPING

PLANTING

LANDSCAPING

LAN

DS

CA

PIN

G

PLANTING

D.G. 88.50'

D.G. 88.70'

NEW SIDEWALK ANDLANDSCAPING TOMATCH ADJACENT

SURFACES

B.G. 8

8.67'

(27.03

m)

BASEMENTPATIO

BELOW

BASEMENTPATIO BELOW

BASEMENTPATIO

BELOW

CLASS BBICYCLEPARKING

NEW BOLLARDS

EL. 84.54'

EL. 84.68'

PATIOPATIO

PATIO PATIO

ENTRY TOBASEMENT

MAINENTRY

MAINENTRY

MAINENTRY

SECONDENTRY

SECONDENTRY

SECONDENTRY

EL. 89.50'

LAN

DS

CA

PIN

G

LANDSCAPING

EXISTINGLANDSCAPING, TO

BE RETAINED

1523 Davie Street, Vancouver, B.C.

LEGAL DESCRIPTION:LOTS 13, 14, 15 INCLUSIVE, ALLOF BLOCK 49, DISTRICT LOT 185,PLAN 92

ZONING:COMPREHENSIVE DEVELOPMENTCD-1 (248)

SURVEY INFORMATION:BASED ON SURVEY INFORMATIONBY HOBBS, WINTER &MACDONALD, B.C. LANDSURVEYORS, DATED: FEBRUARY25, 2016

SITE AREA:2,409.65 m?

SITE COVERAGE:INFILL:

EXISTING:

TOTAL:

Existing fence to be maintained. Clean up brick and concrete, paint metal as per architecture.

Existing driveway to be resurfaced as a pedestrian walk

Existing lawn, trees and hedges to be maintained and restored as needed after construction.

Front patio areas with gates, hedges and fences in between

Existing ornamental planting beds to be retained. Landscape will work with a horticulturalist to clean up and infill these gardens as necessary to maintain and improve the character of the site along Davie St.

Transplant existing rhododendrons from corner of lane to this location

Maintain landscape as much as possible in this area.

Existing stone monument to be maintained.

Transplant existing trees from the area of the proposed new townhomes. Landscape and arborist to assess best trees for retention and transplant.

Secondary entrances off of lane, with shade tolerant planting and paved top of curb

Patio with terraced planters

Patio with terraced planters

Patio with terraced planters

Patio with terraced planters

Window well with gravel in the bottom and drain. Fenced with 3’ metal picket fence and a vine for additional privacy.

450 mm paved top of curb with planting behind where utilities allow

Materials

Existing wrought iron monument to be cleaned up and restored.

Existing wrought iron monument to be cleaned up and restored.

DAVIE STREET

NIC

OLA

STR

EET

Existing ornamental planting beds to be retained. Landscape will work with a horticulturalist to clean up and infill these gardens as necessary to maintain and improve the character of the site along Nicola St.

use 4” pots in this location to protect tree roots. See soil over roots detail on L-4.

Abbotsford Concrete California Pavers in Natural, in a running bond pattern

Abbotsford Concrete Villa Stone Blend of Type 1, 2 and 3 sizes in randompattern, in 50% Sandalwood and 50% Indian Summer

Abbotsford Concrete Villa Stone Type 1 and 2 in Herringbone Pattern, in Teak Blend

Poured in Place Concrete

Existing shrub bed to remain

Lawn

Clear crushed gravel strip at building face

Fill in this area with new fence to match existing fence as closely as possible.

Relocate additional trees from corner of lane and Nichola, if feasible, or new Japanese Maples

Revisions :

Sheet Title:

Scale:1:100

Date:

Project No.2016-22

L-1

Project:

April 7 17 For Rezoning

J o n a t h a n L o s e e L t d.L a n d s c a p e A r c h i t e c t u r e

#102 - 1661 W. 2nd Ave.Vancouver, B.C. V6J 1H3

Ph: 604-669-1003E-mail: [email protected]

Page 3: Boulevard trees adjacent to construction sites must berezoning.vancouver.ca/.../documents/15-LandscapePlan.pdf · Project # 2015-38 Project: ... LAMP POST EXISTING METAL FENCE WITH

77-S

162-Lm

24-Pm57-SjR

21-CE

10-CE

25-Pm

14-Txm

11-Txm

8-Txm6-Txm

8-CE

6-Txm

5-Lm 10-EjPB

5-Txm

10-EjPB

5-Txm

10-EjPB

5-Txm

15-EjPB

5-Txm

3-RNL30-Lp

3-Ea c

4-Pan

11-SjR

8-SjR

19-Bs15-SjR

13-NdGs

6-Txm

3-Rf

3-Rf

3-Rf

3-Pan

4-Pan

2-SjR

6-SjR

3-RP

8-Svh R

1-RP

1-Cm 13-Pm 12-CE 13-CE 13-CE

25-CE

29-Txm

12-CE87-CE6-RhT 3-RhT26-CE

81-Lm

6-RhT

75-CE

2-CV

5-Rf

6-CV

9-Ery

10-Fg 7-Fg5-Fg

4-Fg

3-Rf

4-Ery

3-Rf

68-Ejdd

5-Ery3-Rf

7-Ery

3-Pan2-Pan

4-LSs

6-RP

48-Pm

9-Hb

7-RP

3-Sbl3-Sbl

3-Sv

Level 1 FFE: 89'-6"Basement: 79'-0"

DAVIE STREET

NIC

OLA

STR

EE

T

LANE

EXISTING BUILDING(TO REMAIN IN SAME LOCATION)

PROPOSED NEWTOWNHOMES

CO

NC

RE

TE S

IDE

WA

LK

PROPOSEDNEW

ADDITION

EXISTING GAS METER

SE

TBA

CK

SE

TBA

CK

REFUSE

DN DN

SETBACK

SETBACK

SE

TBA

CK

SE

TBA

CK

(HR

A)

ADJACENT3-STOREY

RESIDENTIALBUILDING

PARKADEENTRY POINT(1500PENDRELLSTREET)

D.G. 86.00'

D.G. 84.95'

D.G. 84.41'

D.G. 86.23'

D.G. 86.85'

D.G. 87.42'EXISTING DRIVEWAY,

RE-PAVED AND USED ASPEDESTRIAN WALWAY

FIRE HYDRANT:SW CORNER OF DAVIE

ST AND NICOLA ST.APPROXIMATELY 29 M

FROM CORNER OFPROPERTY LINE.

MODIFIEDWALKWAY

RE-PAVEDWALKWAY

COMMONWALKWAY

EXISTING MONUMENT SIGN

PROPOSED NEWPATIO AT

BASEMENTLEVEL, TYPICAL.

EXISTING SUMP TO BELOWERED / RELOCATEDAS REQUIRED, NOT TOINTERFERE WITH NEWPATIO

PRESERVEDLANDSCAPING SHOWNIN GREY, TYPICAL

SETBACK

PMT

EL. 83.50'

PROPOSEDTRANSFORMER

UP

PROPERTY LINE: 198.00'

PROPERTY LINE: 197.97'

PRO

PER

TY L

INE:

131

.02'

PRO

PER

TY L

INE:

131

.00'

MAIN ENTRY

SECONDENTRY

MAINENTRY

SECONDENTRY

SECONDENTRYWALKWAY

EXISTING GAS VALVE

EXISTINGUTILITY POLE,TYPICAL

TELUS MANHOLE

EXISTING MANHOLES

EXISTNG CONCRETE CURB

EXISTING CONCRETE APRON

NEW SIDEWALK ANDLANDSCAPING TO MATCH

ADJACENT SURFACES

EXISTINGUTILITYPOLE

EXISTINGCATCHBASIN

EXISTINGLAMP POST

EXISTING METALFENCE WITHBRICK POSTS, TOBE REFINISHEDAND REPAINTEDAS NEEDED.

PORTE COCHERELINE OF ROOFOVERHANGABOVE, TYPICAL

EXISTINGWOODFENCE

NEW WINDOW WELL

NEW WINDOW WELL

DN

INFILL WITHGRAVEL &

TOPSOIL ASNEEDED TO

ENSURE FLUSHWITH EDGE OF

RAMP

DN

B.G. 83.40'

(25.42 m)

B.G. 84.24'

(25.68 m)

B.G. 85.55'

(26.08 m)

B.G. 87.12'

(26.55 m)

B.G. 87.86'

(26.78 m)

B.G. 88.38'

(26.94 m)

B.G. 88.59'(27 m)

B.G. 8

9.11'

(27.16

m)

B.G. 8

9.11'

(27.16

m)

B.G. 87.97'

(26.81 m)

B.G. 86.05'

(26.23 m)

B.G. 8

3.55'

(25.47

m)

B.G. 8

1.02'

(24.7

m)

PLA

NTI

NG

LANDSCAPING

PLANTING

LANDSCAPING

LAN

DS

CA

PIN

G

PLANTING

D.G. 88.50'

D.G. 88.70'

NEW SIDEWALK ANDLANDSCAPING TOMATCH ADJACENT

SURFACES

B.G. 8

8.67'

(27.03

m)

BASEMENTPATIO

BELOW

BASEMENTPATIO BELOW

BASEMENTPATIO

BELOW

CLASS BBICYCLEPARKING

NEW BOLLARDS

EL. 84.54'

EL. 84.68'

PATIO

PATIOPATIO PATIO

ENTRY TOBASEMENT

MAINENTRY

MAINENTRY

MAINENTRY

SECONDENTRY

SECONDENTRY

SECONDENTRY

EL. 89.50'

LAN

DS

CA

PIN

G

LANDSCAPING

EXISTINGLANDSCAPING, TO

BE RETAINED

OF BLOCK 49, DISTRICT LOT 185,PLAN 92

ZONING:COMPREHENSIVE DEVELOPMENTCD-1 (248)

SURVEY INFORMATION:BASED ON SURVEY INFORMATIONBY HOBBS, WINTER &MACDONALD, B.C. LANDSURVEYORS, DATED: FEBRUARY25, 2016

SITE AREA:2,409.65 m?

SITE COVERAGE:INFILL:

EXISTING:

TOTAL:

Existing Japanese Maple transplanted as per arborist report.

Existing Japanese Maple transplanted as per arborist report.

DAVIE STREET

NIC

OLA

STR

EET

GABRIOLA MANSION PLANT LISTID Latin Name Common Name Quantity Scheduled SizeTREESLSs Liquidambar styraciflua 'Slender Silhouette' 'Slender Silhouette' Sweet Gum 4 5 cm calSHRUBSRNL Azalea Northern Lights Northern Lights Azalea 3 # 3 potBs Blechnum spicant Deer Fern 19 # 1 potCE Carex 'Evergold' Golden Sedge Grass 302 # 1 potCV Ceanothus 'Victoria' California Lilac 6 # 3 potCm Clematis Montana rukbra Spring flr. Clematis - Red 1 # 1 potEry Eryngium x 'Big Blue' Big Blue Sea Holly 25 # 1 potEa c Euonymus alata 'Compacta' Dwarf burning bush 3 # 3 potEjdd Euonymus japonicus 'Dan's Delight' Dan's Delight Variegated Boxleaf Euonymus 68 #1 potEjPB Euonymus japonicus 'Paloma Blanca' Paloma Blanca Boxleaf Euonymus 45 # 1 potFg Festuca glauca 'Beyond Blue' Blue Fescue 26 #1 potHb Hydrangea serrata 'Bluebird' Bluebird Hydrangea 9 #5 potS Ligularia dentata 'Othello' Othello Ligularia 77 #1 potLm Liriope muscari 'Silver Dragon' 'Silver Dragon' Lily Turf 248 # 1 potLp Lonicera pileata Privet Honeysuckle 30 # 2 potNdGs Nandina domestica 'Gulf Stream' Gulf Stream Heavenly Bamboo 13 # 2 potPan Panicum virgatum 'Northwind' Switch Grass 16 # 1 potPm Polystichum munitum Sword Fern 110 #1 potRhT Rhododendron 'Jean Marie de Montague' Taurus 15 # 5 potRP Rhododendron-Large Pink Large Pink Rhododendron 17 # 5 potRf Rudbeckia fulgida 'Goldsturm' Goldsturm Black Eyed Susan 23 # 2 potSbl Sambucus nigra 'Black lace' Black leaf Elder 6 #3 potSjR Skimmia japonica 'Rubinetta' Rubinetta Skimmia 99 # 3 potSvh R Spiraea x vanhouttei 'Renaissance' Renaissance Spirea 8 # 2 potSv Syringa vulgaris Common Lilac 3 #5 potTxm Taxus x media 'Hillsii' Hills Yew 100 1.25 m ht

100 shrubs/ perennials selected by LA/ gardener 100 # 2 pot

Revisions :

Sheet Title:

Scale:1:100

Date:

Project No.2016-22

L-1

Project:

April 7 17 For Rezoning

J o n a t h a n L o s e e L t d.L a n d s c a p e A r c h i t e c t u r e

#102 - 1661 W. 2nd Ave.Vancouver, B.C. V6J 1H3

Ph: 604-669-1003E-mail: [email protected]

L-2

LANDSCAPE NOTES

1. Sizes on the planting plan shall be considered minimum sizes.

2. All landscape construction to meet the current edition of the British Columbia Landscape Standards as a minimal acceptable standard. Plant material to the satisfaction of the Landscape Standards for nursery stock. Extend search for plant material to Washington, Oregon, California, and B.C.

3. Root balls to be free of pernicious weeds.

4. Top soil mixtures for the project shall be tested for particle size, Ph, and Nutrient levels, and recommendations provided and amendments made to bring the soil up to acceptable horticultural quality for the desired plant material, trees, or turf planting. Off slab, min. soil depths are 6” for lawn areas, 18” for shrub beds and ground cover plantings. Install 2 inches of composted organic mulch on all shrub beds after planting and rake smooth.

5. Provide positive grades away from buildings and toward lawn drains and catch basins. Slope away from building at a minimum of 2%. The prepared sub-grade shall be approved by the Consultant prior to application of top soil mixtures and finish grading. Slope towards lawn basins at min. 4%.

6. Landscape Contractor is to provide 55 days of maintenance after the date of Substantial Completion. Maintain to level 2 ‘Groomed’ as per British Columbia Landsape Standards. Contractor to provide a one year guarantee for all plant material. Plants installed prior to June (Between Jan 1 and June1) shall be under extended warranty until the June 1 of the following year.

7. Protection of existing trees/shrubs to remain: Install temporary tree protection fencing at drip line of existing hedges, trees, and shrub beds which are to remain. Maintain the fencing during construction. No storage of materials or equipment, or any other activities are allowed within the protection zone during construction until final landscape work is being done in the vicinity. Remove protective fencing and landscape as directed.

8. Planting material on City Boulevard to have the approval of the Parks Dept. prior to installation. Size, species and location require approval at the time of installation.

9. All landscaping to have high effeciency irrigation system to IIABC standards.

Page 4: Boulevard trees adjacent to construction sites must berezoning.vancouver.ca/.../documents/15-LandscapePlan.pdf · Project # 2015-38 Project: ... LAMP POST EXISTING METAL FENCE WITH

Revisions :

Sheet Title:

Scale:1:100

Date:

Project No.2016-22

L-1

Project:

April 7 17 For Rezoning

J o n a t h a n L o s e e L t d.L a n d s c a p e A r c h i t e c t u r e

#102 - 1661 W. 2nd Ave.Vancouver, B.C. V6J 1H3

Ph: 604-669-1003E-mail: [email protected]

L-3

Maintain and clean up existing stone columns and existing fence along Davie St sidewalk

Maintain existing flower beds and trees along Davie St and open lawnarea

Paving stone walkways

Add additional sections of fence to this location to match existing fence.

Page 5: Boulevard trees adjacent to construction sites must berezoning.vancouver.ca/.../documents/15-LandscapePlan.pdf · Project # 2015-38 Project: ... LAMP POST EXISTING METAL FENCE WITH

Uncompacted grade to remain unchanged

Review with arborist prior to beginning construction

** Where not working within tree protection area, shrubs to have 450 mm topsoil

Maximus 100 mm topsoil and 50mm compost within tree protection zone. Do not excavate soil. Return to existing grade around tree trunks to prevent rotting of bark. Use only 10 cm pots within the CPZ. All work to be done under the supervision of the arborist.

Tree Planting over Existing RootsScale: 1:252

L-0

Revisions :

Sheet Title:

Scale:1:100

Date:

Project No.2016-22

L-1

Project:

April 7 17 For Rezoning

J o n a t h a n L o s e e L t d.L a n d s c a p e A r c h i t e c t u r e

#102 - 1661 W. 2nd Ave.Vancouver, B.C. V6J 1H3

Ph: 604-669-1003E-mail: [email protected]

L-4

50x 150 PT CAP HORIZ

100x100 P.T. POST AT 2400 O.C.25X100 P.T. FACIA - SANDWICH SNOW FENCE BETWEEN IT AND POST50x100 P.T. CROSS RAILS

L-70 SNOW FENCING OR APPROVED EQUAL

4" ORANGE GLOW TREE RETENTION FLAGGING TAPE - staple to 25x100

FINISHED GRADE

BACKFILL POST HOLES WITH COMPACTED GRAVEL TYP.

.6 M

1.2M

TREE RETENTION AREA - KEEP OUT TREE RETENTION AREA - KEEP OUT TREE RETENTION AREA - KEEP OUT TREE RETENTION AREA - KEEP OUT

Tree Protection FencingScale: 1:251

Prune only dead or injured branches

Shrubs shall be planted slightly higher in relation to finished grade

50 mm mulch from manufactured compost

create saucer with packed top soil

gently compacted top soil mixture 450 mm deep

scarify bottom of planting pit 75 mm deep prior to spreading top soil

existing sub-grade - native materials

NOTES:1. Min. container size and root spread to CNTAlandscape standards for Nursery Stock.

2. Prune all damaged, diseased, or weak limbs and roots

3. Do not allow roots to dry out during installation process,water plant roots well pror to planting and waterimmediately following planting.

Shrub PlantingScale: 1:253

1.0

m

Prefabricated protective tree collar

Root ball width plus 600 mm min. Compacted to 85% standard proctor density. Scarify bottom and sides of tree pit prior to planting

Keep the soil moist, not water-logged, to the full depth of the roots. 100mm deep saucer formed in top soil for initial first year of watering. Provide 75mm deep of well composted bark mulch over tree pit circumference. Do not mound up against flare of tree. Soil over root ball should not exceed 25mm depth. Remove dead and dying branches. Wait until the second growing season to begin training cuts for shaping and to begin fertilizing.

Min. top soil depth 450mm for shrub beds. For trees, soil depth 1.0 m or depth of root ball, whichever is greater. Topsoil on scarified subgrade. Fill with top soil 2/3rds full and remove strapping and all treated burlap cut all binding material remove girdling roots. Grade to the tops of curbs, walks, and driveways. etc.

Note. do not prune lower branches of fastigiate trees. Do not cut leader.

All wire baskets shall have the top 1/3 of the wire removed prior to planting

Plant at the depth where roots spread from the trunk. Loosen the soil far beyond the dripline of the tree. Rootball supported on a mound of undisturbed subgrade. Stakes do not penetrate or damage root ball. 300 mm min. of top soil around root ball.

Tree PlantingScale: 1:254