Brain Model for Microelectrode Implantation Testing Sandy Deitch Mark Choi Bucknell University Syracuse University Dr. Rousche Bioengineering Department

Brain Model for Microelectrode Implantation Testing

Embed Size (px)

DESCRIPTION

Brain Model for Microelectrode Implantation Testing. Sandy Deitch Mark Choi Bucknell University Syracuse University Dr. Rousche Bioengineering Department. Neural Engineering. What is neural engineering? - PowerPoint PPT Presentation

Citation preview

Page 1: Brain Model for Microelectrode Implantation Testing

Brain Model for Microelectrode Implantation

Testing

Sandy Deitch Mark Choi Bucknell University Syracuse University

Dr. RouscheBioengineering Department

Page 2: Brain Model for Microelectrode Implantation Testing

Neural Engineering

• What is neural engineering?– Combination of neuroscience,

engineering, and clinical medicine

– Characterize and manipulate neural tissue

– Develop interfaces for sensory and motor systems

• Cortical sensory prosthetics is one division of neural engineering

Source: http://www.medem.com/medlb/article_detaillb.cfm?article_ID=ZZZG57C56JC&sub_cat=510

Page 3: Brain Model for Microelectrode Implantation Testing

Cortical Sensory Prosthetics

• First experiments conducted in 1960’s and 1970’s

Electrical stimulation of visual cortex

Perception of phosphenes

• Developments Electrical stimulation of

cortical tissue

Sensory perception

Brindley et al., 1968

Normann et al., 1999

Page 4: Brain Model for Microelectrode Implantation Testing

Microelectrode Stimulation of Auditory Cortex

• Cochlear implant cannot be used when nerves not intact

• Instead, implant directly into auditory cortex (Heschl’s gyrus)

• Polyimide-based intracortical electrode array– Flexible– Biocompatible– Coated with PGA

Rousche et al., 1999

Page 5: Brain Model for Microelectrode Implantation Testing

Problem

• Implant micromechanical testing is done to determine ideal microelectrode structure• Current models are not sufficient

– Human cadaver brains– Rat brains

• Better model of human brain is needed for mechanical implantation testing

Page 6: Brain Model for Microelectrode Implantation Testing

Solution• Brain Model

– Anatomy– Mechanical Properties– Radial pressure variations– Protocol

• Experimentation– Techniques for inserting

flexible device– Measure insertion forces

before and after PGA coating

Page 7: Brain Model for Microelectrode Implantation Testing

Force Testing

• To find percentage of agar gel that most closely matches mechanical properties of live brain tissue and pia membrane

• Compare agar gel to cadaver brain tissue and literature data

Page 8: Brain Model for Microelectrode Implantation Testing

Force Acquisition Systems

•2.2% overall increase from balance force measurement to load cell force measurement

22.33 22.21 21.7521.05

23.36

21.00

27.8526.30

16.82

21.20

0

5

10

15

20

25

30

1 2 3 4 5

Insertion

Fo

rce

(m

N)

Balance

Load Cell

Peak forces for five separate microelectrode wire insertions into 5% agar gel at various insertion speeds, locations, and depths as measured by the balance force acquisition system and the load

cell force acquisition system simultaneously

Page 9: Brain Model for Microelectrode Implantation Testing

Force Testing: Matching Live Brain Tissue

4.031.090.950

1

1

2

2

3

3

4

4

5

5

Live Brain (extrapolatedfrom Howard data)

0.5% Agar Gel 1% Agar Gel

Material

Pea

k F

orc

e (m

N)

• Howard et al. (1999) inserted probe into live human brain• 0.5% agar gel has mechanical properties similar to live brain tissue

Peak force associated with inserting microelectrode wire 2 cm at approximately 0.33 mm/s into 0.5% and 1% agar gel for comparison to peak force extrapolated from Howard (1999) data

Page 10: Brain Model for Microelectrode Implantation Testing

Force Testing: Matching Pia Membrane

• Jensen et al. (1999) inserted microelectrode through rat pia membrane

• 0.83% agar gel has mechanical properties similar to rat pia membrane

Penetration force associated with inserting microelectrode wire 2 mm at approximately 2 mm/s into 0.75%, 0.83%, and 1% agar gel pia membranes for comparison to penetration force associated with inserting microelectrode through rat pia membrane (Jensens data)

1.15 0.75 1.990.95

0

0.5

1

1.5

2

2.5

3

Rat Pia (JensensData)

0.75% Agar GelPia

0.83% Agar GelPia

1% Agar Gel Pia

Pen

etr

ati

on

Fo

rce (

mN

)

Page 11: Brain Model for Microelectrode Implantation Testing

Brain Model• Plaster mold of model

brain

• 0.5% agar gel for brain tissue

• 0.83% agar gel for pia membrane

• Fissures and Heschl's gyrus incorporated into model for more realistic anatomy

Page 12: Brain Model for Microelectrode Implantation Testing

Techniques for Microelectrode Insertion

• Flexible polyimide-based microelectrode

• Five categories for Implantation Testing1) No coating

2) PGA coating on tip

3) PGA coating on tip and shaft

4) Plastic coating on shaft

5) PGA coating on tip and

plastic coating on shaft

tipsshaft

Page 13: Brain Model for Microelectrode Implantation Testing

Insertion Force Testing• Only have

microelectrodes intended for use in rats

• Microelectrodes with no coating buckle

• Microelectrodes with no tip coating curve within gel

• Microelectrodes with plastic shaft + PGA coating on tip implant vertically

0.25 0.64 1.24 2.990.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

1 tip, plastic shaft,no tip coating

4 tips, plasticshaft, no tip

coating

2 tips, plasticshaft, PGA tip

4 tips, plasticshaft, PGA tip

Microelectrode

Inse

rtio

n F

orc

e (m

N)

Insertion force associated with inserting polyimide-based microelectrodes with different coatings 2 mm into 0.5% agar gel at 2 mm/s

Page 14: Brain Model for Microelectrode Implantation Testing

Radial Pressure Variations

• Brain expands and contracts with pulsatile blood flow

• Using balloon in between hemispheres of brain model to force the model to expand and contract

• Problem: Model broke easily• Solution: Use plastic wrap as dura membrane• Future: Control electronically rather than

manually

Page 15: Brain Model for Microelectrode Implantation Testing

Brain Model in Skull

• Brain model in skull to simulate surgical procedure in humans• Implant life-size microelectrodes into Heschl's gyrus of model

brain• Measure insertion forces for microelectrodes with new load cell• Chronic oscillatory testing with microelectrodes in skull possible

Page 16: Brain Model for Microelectrode Implantation Testing

Conclusions• 0.5% agar gel mechanically models live human

brain tissue

• 0.83% agar gel mechanically models pia membrane

• Polyimide-based microelectrode with plastic lining on the shaft and PGA coating on the tip is promising

• Brain model can be used to test microelectrode insertion forces and may aid in developing better device design

Page 17: Brain Model for Microelectrode Implantation Testing

References(1) Das, R., Gandhi, D., Krishnan, S., Saggere, L., Rousche, P.J., 2006. Cortical neuroprosthesis design: A

generalized, benchtop system to assess implant micromechanics.

(2) Rousche, P.J., Normann, R.A., 1998. Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex. Journal of Neuroscience Methods 82 (1), 1-15.

(3) Rousche, P.J., Pellinen, D.S., Pivin, D.P., Williams, J.C., Vetter, R.J., Kipke, D.R., 2001. Flexible Polyimide-Based Intracortical Electrode Arrays with Bioactive Capability. IEEE Transactions on Biomedical Engineering 48 (3), 361-371.

(4) Howard, M.A., Abkes, B.A., Ollendieck, M.C., Noh, M.D., Ritter, R.C., Gillies, G.T., 1999. Measurement of the Force Required to Move a Neurosurgical Probe Through in vivo Human Brain Tissue. IEEE Transactions on Biomedical Engineering 46 (7), 891-894.

(5) Howard, M.A., Volkov, I.O., Mirsky, R., Garell, P.C., Noh, M.D., Granner, M., Damasio, H., Steinschneider, M., Reale, R.A., Hind, J.E., Brugge, J.F., 2000. Auditory Cortex of the Human Posterior Superior Temporal Gyrus. The Journal of Comparative Neurology 416 (1), 79-92.

(6) Witelson, S.F., Kigar, D.L., 1992. Sylvian Fissure Morphology and Asymmetry in Men and Women: Bilateral Differences in Relation to Handedness in Men. The Journal of Comparative Neurology 323 (1), 326-340.

(7) Normann, R.A., Maynard, E.M., Rousche, P.J., Warren, D.J., 1999. A neural interface for a cortical vision prosthesis. Vision Research 39 (1), 2577-2587.

(8) Brindley, G., Lewin, W., 1968. Short- and long-term stability of cortical electrical phosphenes. Journal of Physiology 196 (2), 479-493.

(9) Dobelle, W., Mladejovsky, M., 1974. Phosphenes produced by electrical stimulation of human occipital cortex, and their application to the development of a prosthesis for the blind. Journal of Physiology 243 (2), 553-576.

(10) Pollen, D.A., 1975. Some perceptual effects of electrical stimulation of the visual cortex in man. The nervous system 2 (1), 519-528.

Page 18: Brain Model for Microelectrode Implantation Testing

Acknowledgements• REU program: Novel Materials and Processing

in Chemical and Biomedical Engineering– Director: C.G. Takoudis

• REU program sponsors– NSF (EEC-0453432 Grant)– DoD-ASSURE

• Advisor: Dr. Rousche• Graduate students:

– Ronnie Das– Devang Gandhi– Lukasz Zientara