GENUINE X-RAY & RADIOLOGICAL EQUIPMENTS PVT. LTD. Plot No. 3, Radhe Industrial Estate, Block No. 497 (P), Tajpur Road, Sarkhej - Bavla Road, Changodar, Ta. Sanand, Ahmedabad - 382 213. Gujarat, India Phone : +91 - 2717 - 298934 E-mail : Website : genuinexray@rediffmail.com [email protected] www. genuinexray.com REVOLUTION IN RADIOLOGY ROOM Dimensions as per AERB Guidelines - L 4.5 x B 4.0 x H 2.75 meters. All Machine Design / Technical Specificaons shown in catalogue are subject to change without any prior noce as standard procedure and constant improvement. Chest Stand Control Unit Table Centre Column Center Tube Column Stand 277 cm X- Ray Examination Room All Dimensions are in cm Double Leaf Door lined with 2 mm lead. 235 cm X-Ray Tube Head MPB With Lead Glass viewing Window of 2.0 mm Lead equivalence Examination Table Unit Electronics Unit Electronics SALIENT FEATURES 300mA, 500mA and 700mA LINE FREQUENCY RADIOGRAPHY X-RAY SYSTEMS Micro-processor based, Easy-Operational and User-Friendly X-Ray Control Console. Micro-Processor controlled input line voltage compensation. Modular and Smart Card based design for easy service. Teflon wires used for Internal wiring for protection against Heat and Fire. Powerful Circuit design provides maximum mA & kVp output accuracy. Micro-Processor based real time exposure. Exposure Trigger circuit control by SCR / TRIAC for soft firing. Dual Exposure Switch. (Wired Hand Switch & Feather Touch Switches on Control Console) Audible Tone at time of X-Ray Exposure. Miniature Circuit Breaker protects against overload. CVT with Electronic Stabilizer Card for mA circuit. Micro-Processor protects X-Tube life from overload due to exposure factor selection automatically. Precise selection of mAs brings better quality and reduces radiation time. Auto shut down facilities (machine will automatically switch off after 30 min. if it is not in use). Two options are available for Console : Stand Mounting & Wall Mounting. CONTROL PANEL GOVERNMENT OF INDIA AERB APPROVED IS:7620 PART-1 CM/L - 3950571 REVOLUTION IN RADIOLOGY Certified & Approved by : CLINICAL OUTPUT 400 cm 450 cm All wall of the Examination Room are 23 cm (9”) thick made of bricks. Autho. Dealer :

Brochure Fixed Radiology System for Client

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

GENUINE X-RAY & RADIOLOGICALEQUIPMENTS PVT. LTD.

Plot No. 3, Radhe Industrial Estate, Block No. 497 (P),Tajpur Road, Sarkhej - Bavla Road, Changodar, Ta. Sanand,Ahmedabad - 382 213. Gujarat, IndiaPhone : +91 - 2717 - 298934

E-mail :

Website :

[email protected]@genuinexray.com

www. genuinexray.com

REVOLUTION IN RADIOLOGY

ROOM Dimensions as per AERB Guidelines - L 4.5 x B 4.0 x H 2.75 meters.

All Machine Design / Technical Specifica�ons shown in catalogue are subject to change without any prior no�ce as standard procedure and constant improvement.

Chest

Stand

ControlUnit

Table Centre

Column Center

Tube ColumnStand

277

cm

X- Ray Examination Room

All Dimensions are in cm

Dou

ble

Leaf

Doo

rlin

ed w

ith 2

mm

lead

.

235 cm

X-RayTube Head

MPB With Lead Glassviewing Window of 2.0mm Lead equivalence

ExaminationTable

UnitElectronicsUnit

Electronics

SALIENT FEATURES

300mA, 500mA and 700mA

LINE FREQUENCYRADIOGRAPHY X-RAY SYSTEMS

Micro-processor based, Easy-Operational and User-Friendly X-Ray Control Console.

Micro-Processor controlled input line voltage compensation.

Modular and Smart Card based design for easy service.

Teflon wires used for Internal wiring for protection against Heat and Fire.

Powerful Circuit design provides maximum mA & kVp output accuracy.

Micro-Processor based real time exposure.

Exposure Trigger circuit control by SCR / TRIAC for soft firing.

Dual Exposure Switch. (Wired Hand Switch & Feather Touch Switches on Control Console)

Audible Tone at time of X-Ray Exposure.

Miniature Circuit Breaker protects against overload.

CVT with Electronic Stabilizer Card for mA circuit.

Micro-Processor protects X-Tube life from overload due to exposure factor selection automatically.

Precise selection of mAs brings better quality and reduces radiation time.

Auto shut down facilities (machine will automatically switch off after 30 min. if it is not in use).

Two options are available for Console : Stand Mounting & Wall Mounting.

CONTROL PANEL

GOVERNMENT OF INDIA

AERB APPROVEDIS:7620

PART-1CM/L - 3950571 REVOLUTION IN RADIOLOGY

Certified & Approved by :

CLINICAL OUTPUT

400 cm

450 cm

All wall of the Examination Roomare 23 cm (9”) thick made of bricks.

Autho. Dealer :

with Horizontal Bucky Table

with 5- Position Bucky Table

BASIC RADIOGRAPHY SYSTEM

ULTRA RADIOGRAPHY SYSTEM

with 4- Way Floating Bucky Table

SMART RADIOGRAPHY SYSTEM

LF Generator Series offers advanced high quality Radiographic capabilities with unmatched performance and reliability resulting in the lowest cost of ownership over the product lifetime. This Generator is suitable for Film and CR - Based Radiographic systems and features leading edge micro-processor based controls to minimize patient doze and maximize image quality while demonstrating excellent reproducibility with user-friendly operator controls.

TECHNOLOGY

All Radiography Systems come with Floor to Ceiling Column Tube Stand fully counter balanced.

Optional Ceiling Free Column Tube Stand available on demand.

PedestalControl Panel

PhaseConverter

H.T.Transformer Vertical Bucky Control Unit

X - Ray Tube

H.V. Cable

OPTIONALX- RAY GENERATOR

LINE FREQUENCY RADIOGRAPHY X-RAY SYSTEMS

INPUT RATING

LINE RESISTANCE

OUTPUT RATING

CONTROL PANEL

RAD kVp RANGE

RAD mAs RANGE

RAD mA RANGE

RAD EXPOSURE TIME

DIGITAL DISPLAY

X-RAY TUBE TYPE

RECTIFICATION

X-RAY FOCAL SPOT

MODEL NAME GXL-D300 GXL- D500 GXL- D700

POWER SUPPLYREQUIREMENT

PHASE CONVERTER

H. V. CABLE

H. T. TRANSFORMER

Microprocessor�controlledfeather�touch�operated

Microprocessor�controlledfeather�touch�operated

Microprocessor�controlledfeather�touch�operated

KV,�mA,�mAs,�Timer(Displayed�on�Control�Panel)

KV,�mA,�mAs,�Timer(Displayed�on�Control�Panel)

KV,�mA,�mAs,�Timer(Displayed�on�Control�Panel)

TECHNICAL SPECIFICATION

3 Phase

400 - 440 VAC / 32 A / 50Hz /± 10%

0.5 Ohms

24 kW

40 - 100 kVp (Step of 1 kVp and 10 kVp)

2 - 250 mAS (Step of 1 mAs and 10 mAs)

Small Focus - 50mA, 100mA, 200mA

Large Focus - 200mA, 300mA

0.02 - 5.0 Sec.

Rotating Anode Dual Focus (Shell Type)

Full Wave Rectification

1 mm² Small, 2.0 mm² Large

Column Stand for X-Ray Tube with movements

covering full length of X-Ray Table

Horizontal Bucky Table

5- Position Bucky Table

4- Way Floating Bucky Table

3 Phase to 1 Phase converting transformer

H. V. Cables 1 Pair

H.T. Transformer oil cooled with Stand

3 Phase

400 - 440 VAC / 63 A / 50Hz /± 10%

0.2 Ohms

40 kW

40 - 125 kVp (Step of 1 kVp and 10 kVp)

2 - 250 mAS (Step of 1 mAs and 10 mAs)

Small Focus - 50mA, 100mA

Large Focus - 200mA, 300mA, 500mA

0.02 - 5.0 Sec.

Rotating Anode Dual Focus (Shell Type)

Full Wave Rectification

1 mm² Small, 2.0 mm² Large

Column Stand for X-Ray Tube with movements

covering full length of X-Ray Table

Horizontal Bucky Table

5- Position Bucky Table

4- Way Floating Bucky Table

3 Phase to 1 Phase converting transformer

H. V. Cables 1 Pair

H.T. Transformer oil cooled with Stand

3 Phase

400 - 440 VAC / 63 A / 50Hz /± 10%

0.2 Ohms

40 kW

40 - 125 kVp (Step of 1 kVp and 10 kVp)

2 - 500 mAS (Step of 1 mAs and 10 mAs)

Small Focus - 100mA

Large Focus - 200mA, 300mA, 500mA, 700mA

0.02 - 5.0 Sec.

Rotating Anode Dual Focus (Shell Type)

Full Wave Rectification

0.6 mm² Small, 1.5 mm² Large

Column Stand for X-Ray Tube with movements

covering full length of X-Ray Table

Horizontal Bucky Table

5- Position Bucky Table

4- Way Floating Bucky Table

3 Phase to 1 Phase converting transformer

H. V. Cables 1 Pair

H.T. Transformer oil cooled with Stand

FLOOR TO CEILING

TUBE STAND

BUCKY TABLEWITH MOVING GRID

GXL- D300 / GXL- D500 / GXL- D700