2
R Patent Pending ST Switch Safety Test Switch VISIBLE OPEN, YET FINGER-SAFE DESIGN ACCEPTS SHIELDED BANANA PLUGS FT SWITCH CUTOUT SIZE

Brochure ST Switch lt 2015-1 - SecuControl brochure lt.… · R Patent Pending ST Switch Safety Test Switch VISIBLE OPEN, YET FINGER-SAFE DESIGN ACCEPTS SHIELDED BANANA PLUGS FT SWITCH

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Brochure ST Switch lt 2015-1 - SecuControl brochure lt.… · R Patent Pending ST Switch Safety Test Switch VISIBLE OPEN, YET FINGER-SAFE DESIGN ACCEPTS SHIELDED BANANA PLUGS FT SWITCH

R

Patent Pending

ST Switch Safety Test Switch

VISIBLE OPEN, YET FINGER-SAFE DESIGN

ACCEPTS SHIELDED BANANA PLUGS

FT SWITCH CUTOUT SIZE

Page 2: Brochure ST Switch lt 2015-1 - SecuControl brochure lt.… · R Patent Pending ST Switch Safety Test Switch VISIBLE OPEN, YET FINGER-SAFE DESIGN ACCEPTS SHIELDED BANANA PLUGS FT SWITCH

www.secucontrol.com

Testing Solutions for Electric PowerSecuControl, Inc., 2873 Duke StreetAlexandria, VA 22314, ph: +1 703 838 7677© SecuControl 1/2015 Due to continuous product improvements SecuControl reserves the right to change the content of this #yer without further notice.

While most parts of the electrical grid are

modernizing rapidly, test access points often

still date back the days of electromechanical

relays. The ST Switch o$ers a new approach

to testing, %tting today’s world of advanced

micro-processor relays and intelligent

devices:

V-0UL94 "ammability class

30 A continuous

500 A for 1 second

≤ 2 mΩ

3.0 kV RMS for 1 minute between

adjacent contact pairs and between

any contact pair and other metal parts

3.0 kV RMS for 1 minute between open

contacts when test pin is inserted

IP20 (without optional cover)

SecuControl ST Switches have been classi%ed as electromagneti-

cally benign and are therefore excluded from the scope of the

European Community Directive 2004/108/EC.

SecuControl ST Switches meet or exceed all requirements from ANSI /

IEEE C37.90-2005

Voltage impulse

Dielectric withstand

Contact resistance

Enclosure protection

Current withstand

Maximum voltage

Technical Speci#cationsKey Features

Finger-safe design eliminates risk to touch

live voltages

Automatic make-before-break CT shorting

upon CT disconnect pin insertion

Keyed disconnect pins prevent mistakes

Visible open via

integrated

status window

Anti-arcing design - contact opening

direction against the formation of arcs

Integrated jacks for shielded banana plugs

Slide-on dust cover with operation

instructions and link to dedicated website

Well legible, customizable labeling

Fits standard FT switch cutouts

- INCREASED SAFETY

- EASIER OPERATION

- IMPROVED TEST EFFICIENCY

ST Switch in Normal Operation:

ST Switch in Test Position:

disconnect pin in parking position

double springs safely close contact

status observation window

disconnect pin in contact position

status window shows open contact

banana jacks for easy test access

status window

Principle of Operation