BSC Disceription B9

Embed Size (px)

Citation preview

  • 7/30/2019 BSC Disceription B9

    1/112

    Alcatel GSM

    A9130 BSC Evolution Hardware

    Description

    BSC & TC Document

    Sub-System Description

    Release B9

    3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    2/112

    Status RELEASED

    Short title A9130 BSC Evolution HW Description

    All rights reserved. Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel.

    BLANK PAGE BREAK

    2 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    3/112

    Contents

    Contents

    Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    1.1 Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2 Subracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.3 Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    1.3.1 Evolium A9130 BSC Evolution Naming Conventions . . . . . . . . . . . . . . . . . . . . . . . 131.3.2 Stand Alone Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151.3.3 Rack Shared Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161.3.4 Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    2 Cabinet Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    2.1 Layout and Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.2 Hardware Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.3 Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.4 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    2.4.1 Temperature and Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.4.2 Atmospheric Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.4.3 Solar Radiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.4.4 Dust and Particles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.4.5 Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.4.6 Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.4.7 Green Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    3 Power System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    3.1 Power Distribution Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283.1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283.1.2 Mechanical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.1.3 Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    3.1.4 Power Station Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.1.5 Connection to the Hosted Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.1.6 Earthing Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.1.7 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.1.8 Provision for Future Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.1.9 JSXPDU Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.1.10 Power Distribution Cable Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    3.2 Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    4 ATCA Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    4.1 ATCA Shelf Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344.1.1 Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.2 Node Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    4.1.3 Hub Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.4 Rear Transition Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.5 Power Entry Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.6 Power Distribution System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364.1.7 Blowers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394.1.8 Shelf Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394.1.9 Personality Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394.1.10 Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394.1.11 Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404.1.12 Distribution Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404.1.13 Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

    4.2 JBXOMCP/JBXCCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414.2.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

    4.2.2 Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

    3BK 20980 AAAA TQZZA Ed.07 3 / 112

  • 7/30/2019 BSC Disceription B9

    4/112

    Contents

    4.2.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434.2.4 Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454.2.5 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

    4.3 JBXSSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474.3.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474.3.2 Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

    4.3.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494.3.4 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.3.5 Reset Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534.3.6 Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

    4.4 JAXSSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544.4.1 Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544.4.2 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554.4.3 Ethernet Uplink Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

    4.5 JBXTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574.5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574.5.2 Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574.5.3 Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

    4.5.4 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624.5.5 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634.6 JAXSMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

    4.6.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644.6.2 Payload Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 664.6.3 Shelf Management Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 664.6.4 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684.6.5 Frame Ground and ESD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684.6.6 Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694.6.7 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694.6.8 Ethernet Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

    4.7 JAXPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714.7.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

    4.7.2 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724.7.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734.7.4 Alarm I/O Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734.7.5 Handle Toggle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734.7.6 Alarm Reset Push Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734.7.7 Shelf Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

    4.8 JBXPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 754.8.1 JBXPS Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 764.8.2 Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 764.8.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 774.8.4 Handle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

    4.9 JBXFAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

    4.9.1 Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.9.2 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.9.3 Handle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

    4.10 ATCA Fillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 794.10.1 JBXFILL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804.10.2 JAXFILL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

    5 JSXLIU/JSXLIUB Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

    5.1 JSXLIU/JSXLIUB Shelf Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 845.1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 845.1.2 Shelf Position in the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 845.1.3 Main Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 855.1.4 Mechanical Housing Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

    5.1.5 JSXLIU/JSXLIUB Shelf Internal Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 885.2 JBXLIU/JBLIU75 Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

    4 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    5/112

    Contents

    5.2.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 905.2.2 Hardware Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 935.2.3 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 965.2.4 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 975.2.5 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

    5.3 JBXMUX Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

    5.3.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 985.3.2 JBXMUX Hardware Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 985.3.3 Front Panel Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1035.3.4 Backplane Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1045.3.5 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1055.3.6 Power Supply Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1055.3.7 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

    5.4 JBXPEM Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1075.4.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1075.4.2 JBXPEM Architecture and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1075.4.3 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1105.4.4 Back Plane Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

    5.4.5 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1115.5 Dummy Panel (JBXDUM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1125.6 LIU Filler (JMXF1U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1125.7 LIUB Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

    3BK 20980 AAAA TQZZA Ed.07 5 / 112

  • 7/30/2019 BSC Disceription B9

    6/112

    Figures

    Figures

    Figure 1: Evolium A9130 BSC Evolution 600 TRX Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Figure 2: Evolium A9130 BSC Evolution Rack Shared by Two BSCs Configuration . . . . . . . . . . . . . . . . . . . . 16

    Figure 3: Cabinet Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    Figure 4: Evolium A9130 BSC Evolution Hardware Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    Figure 5: JSXPDU Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Figure 6: JSXPDU Front View and Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    Figure 7: Shelf Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Figure 8: Block Diagram of a Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    Figure 9: ATCA Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

    Figure 10: ATCA Subrack Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    Figure 11: ATCA Subrack Back View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    Figure 12: Shelf Low Power Distribution System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Figure 13: Shelf High Power Distribution System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    Figure 14: JBXOMCP/JBXCCP Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

    Figure 15: Location of Front Plate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

    Figure 16: Location of Reset Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

    Figure 17: Location of USB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

    Figure 18: Blade Functional Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

    Figure 19: JBXSSW Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

    Figure 20: JBXSSW LED Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

    Figure 21: Base Interface LED Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

    Figure 22: Connector Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

    Figure 23: Reset Key Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

    Figure 24: Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

    Figure 25: JAXSSW Front Plate LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

    Figure 26: BSC Global Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

    Figure 27: JBXTP Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

    Figure 28: JAXSMM Hardware Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

    Figure 29: JAXSMM Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

    Figure 30: JAXPC Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

    Figure 31: JAXPC Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

    Figure 32: Rotary Switches on JAXPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

    Figure 33: JBXPS Functional Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

    Figure 34: JBXPS Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

    Figure 35: JBXFAN Front Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

    Figure 36: JBXFILL View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

    Figure 37: JAXFILL View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

    Figure 38: JSXLIU/JSXLIUB Shelf in the BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

    Figure 39: JSXLIU/JSXLIUB Shelf Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

    6 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    7/112

    Figures

    Figure 40: JSXLIU/JSXLIUB Shelf Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

    Figure 41: LIU Hosted Strips and Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

    Figure 42: JSXLIU/JSXLIUB Shelf Back-Plane Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88

    Figure 43: Platform Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

    Figure 44: JBXLIU/JBLIU75 Board Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

    Figure 45: JBXLIU/JBLIU75 Board Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

    Figure 46: LIU Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

    Figure 47: JBXMUX Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

    Figure 48: 1000 Base-T RJ45 Connector Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

    Figure 49: JBXMUX Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

    Figure 50: ESD Mitigation Mechanism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

    Figure 51: JBXPEM Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

    Figure 52: JBXPEM Board Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Figure 53: JBXPEM Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

    Figure 54: JBXPEM Side View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

    Figure 55: JBXDUM Front and Side Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

    Figure 56: JMXF1U Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

    Figure 57: JSXLIUB Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

    3BK 20980 AAAA TQZZA Ed.07 7 / 112

  • 7/30/2019 BSC Disceription B9

    8/112

    Figures

    8 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    9/112

    Preface

    Preface

    Purpose The Evolium A9130 BSC Evolution Hardware Description describes thecabinets, subracks and modules of the A9130 BSC Evolution.

    Whats New In Edition 07

    Section LEDs (Section 4.8.3) was updated.

    In Edition 06

    Section JBXLIU/JBLIU75 Board (Section 5.2) was updated for the LIU boardsupporting the 75 ohm cables solution.

    Section LIUB Label (Section 5.7) was added.

    In Edition 05

    Color for H2 LED on JBXTP was updated in LEDs (Section 4.5.4).

    In Edition 04Description improvement in the following sections:

    Introduction (Section 4.5.1)

    Layout and Facilities (Section 2.1)

    In Edition 03

    Logical slot numbering was added in Evolium A9130 BSC Evolution NamingConventions(Section 1.3.1).

    In Edition 02

    Figures 2, 13, 26, 29, 40 and 44 were updated.

    In Edition 01

    First official release of the document.

    Audience This manual is intended for:

    Commissioning personnel

    3BK 20980 AAAA TQZZA Ed.07 9 / 112

  • 7/30/2019 BSC Disceription B9

    10/112

    Preface

    System support engineers

    Training department personnel (for reference use)

    Any other personnel requiring an overview of the Evolium A9130 BSC

    Evolution hardware.

    Assumed Knowledge The reader must have a general knowledge of telecommunications systems,terminology and Evolium A9130 BSC Evolution functions.

    10 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    11/112

    1 Overview

    1 Overview

    The Overview provides information needed by project managers and foremen,for presentation to the customer and for site planning.

    3BK 20980 AAAA TQZZA Ed.07 11 / 112

  • 7/30/2019 BSC Disceription B9

    12/112

    1 Overview

    1.1 Cabinet

    The Evolium A9130 BSC Evolution hardware consists of an indoor cabinetwhich is housed in a telecommunications building. It contains subracks, powerdistribution unit, PBAs, modules and cabling.

    The cabinet is designed for buildings with a minimum ceiling height of 2.7meters.

    Cable entry to the cabinet can be from:

    The topIf the cabinet is mounted on a solid floor, cable ducts in the ceiling carry thecables to the top of the cabinet.

    The bottomIf the cabinet is mounted on a raised floor, cable ducts in the floor carry thecables to the bottom of the cabinet.

    The cabinet consists of a rack fitted with front and rear doors. When the

    doors are closed, the equipment is EMI protected. The doors can be easilyremoved for maintenance.

    The arrangement of the subracks in the cabinet takes into account therequirements for:

    Thermal cooling, achieved with forced-air cooling

    Minimization of floor space

    Ease of access for maintenance, from the front of the cabinets

    Future system expansion.

    1.2 Subracks

    The following types of subracks are used in the Evolium A9130 BSC Evolution:

    ATCAThe ATCA 19" subrack is made of stainless steel. There is one mountingbracket on each side of the shelf, designed for front-mounting into a rack.Depending on the rack in which the shelf is installed, there are two possiblelocations for the mounting brackets on the side of the shelf.For more information about ATCA subracks and hosted boards, refer toATCA Shelf (Section 4).

    Line Interface Unit (JSXLIU)The JSXLIU/JSXLIUB subrack assumes the concentration of 256 E1 on oneGiga Ethernet link.For more information about JSXLIU/JSXLIUB subracks and hosted boards,refer to JSXLIU/JSXLIUB Shelf (Section 5).

    Power Distribution Unit (JSXPDU).The JSXPDU provides power distribution inside the cabinet.For more information about the JSXPDU, refer to Power Distribution Unit(Section 3.1).

    12 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    13/112

    1 Overview

    1.3 Configurations

    1.3.1 Evolium A9130 BSC Evolution Naming Conventions

    The following table lists the naming conventions used for Evolium A9130

    BSC Evolution configurations.

    Configuration Description

    200 TRX This configuration requires 1 active JBXCCP boardand 1 standby JBXCCP board.

    400 TRX This configuration requires 2 active JBXCCP boardand 1 standby JBXCCP board.

    600 TRX This configuration requires 3 active JBXCCP boardand 1 standby JBXCCP board.

    Table 1: Evolium A9130 BSC Evolution Configuration Naming Conventions

    The follwing table gives the boards allocation for the ATCA shelf.

    Physical slots

    Boards Qty 1 2 3 4 5 6 7 8 9 10 11 12 13 14

    JBXSSW 2 x x

    JBXCCP 1 to 3

    +1 spare

    2 0 1 3 u u u

    JBXTP 2 x x

    JBXOMCP 2 u x x u u u

    JAXSSW 2 u u u u u x x u u u u u u

    u : Slot is not used and closed with a filler

    JBXCCP in slot 10 is always present for redundancy function, but it has to beconsidered as a floating spare during operation.

    3BK 20980 AAAA TQZZA Ed.07 13 / 112

  • 7/30/2019 BSC Disceription B9

    14/112

    1 Overview

    The logical slot numbering is different and is given by the following table.

    Area Front/Rearside

    Physical slotposition in thearea

    Area

    value

    Value to beadded to theslot position

    Slot positionvalue

    Slot are Front panel From 1 up to 14 0 +0 From 1 up to 14

    Rear area Rear side From 1 up to 14 1 +16 From 17 up to 30

    JBXPS area Rear side From 1 up to 4 2 +32 From 33 up to 36

    JAXPC area Rear side From 1 up to 2 3 +48 From 49 up to 50

    JAXSMM area Rear side From 1 up to 2 4 +64 From 65 up to 66

    JBXFAN area Front panel From 1 up to 4 5 +80 From 81 up to 84

    Table 2: Logical Slot Numbering

    14 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    15/112

    1 Overview

    1.3.2 Stand Alone Configuration

    The following figure shows the rack layout for an Evolium A9130 BSC Evolution600 TRX configuration.

    C L OS E D / O P EN H / S O O S

    C L OS E D / O P EN H / S O O S

    CLOSED / O PE N H / S O O S

    C L OS E D / O P EN H / S O O S

    JSXLIU

    Shelf 1

    JSXATCAShelf 3

    (JSXATCA Shelf 4)

    JSXPDU

    Free space

    (JSXLIU Shelf 2)

    Free space

    48 / 60VDC

    4A

    48 / 60VDC

    4A

    XPEM XLIU XMUXXLIU XLIU X LIU X LIU X LIU XLIU X LIU XPEMXMUX XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    Air inlet

    JBXSSW

    JBXTP

    JBXCCP

    JBXOMCP

    JBXTP

    NotUsed

    NotUsed

    NotUsed

    NotUsed

    JBXCCP

    JBXCCP

    JBXCCP

    JBXOMCP

    JBXSSW

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

    Figure 1: Evolium A9130 BSC Evolution 600 TRX Configuration

    3BK 20980 AAAA TQZZA Ed.07 15 / 112

  • 7/30/2019 BSC Disceription B9

    16/112

    1 Overview

    1.3.3 Rack Shared Configuration

    The following figure shows the rack layout for two Evolium A9130 BSC Evolutionrack shared by two BSCs configuration.

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    C L OS E D / O P EN H / S O O S

    C L OS E D / O P EN H / S O O S

    CLOSED / O PE N H / S O O S

    C L OS E D / O P EN H / S O O S 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0

    C L OS E D / O P EN H / S O O S

    C L OS E D / O P EN H / S O O S

    CLOSED / O PE N H / S O O S

    C L OS E D / O P EN H / S O O S

    48/60VDC

    4A

    48/60VDC

    4A

    XPEM XLIU XMUXXLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XPEMXMUX

    JSXLIU

    Shelf 1(BSC1)

    JSXATCAShelf 3(BSC1)

    JSXATCAShelf 4(BSC2)

    JSXPDU

    JBXSSW

    JBXTP

    JBXCCP

    Air inlet

    Air inlet

    JBXOMCP

    JSXLIUShelf 2(BSC2)

    48/60VDC

    4A

    48/60VDC

    4A

    XPEM XLIU XMUXXLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XLIU XPEMXMUX

    JBXTP

    NotUsed

    NotUsed

    NotUsed

    NotUsed

    JBXCCP

    JBXCCP

    JBXCCP

    JBXOMCP

    JBXSSW

    JBXSSW

    JBXTP

    JBXCCP

    JBXOMCP

    JBXTP

    NotUsed

    NotUsed

    NotUsed

    NotUsed

    JBXCCP

    JBXCCP

    JBXCCP

    JBXOMCP

    JBXSSW

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

    Figure 2: Evolium A9130 BSC Evolution Rack Shared by Two BSCsConfiguration

    16 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    17/112

    1 Overview

    1.3.4 Standards

    The complete system is fully compliant with:

    PICMG 3.0 R1.0 (AdvancedTCA) specifications defining mechanics, board

    dimensions, power distribution, power and data connectors and system

    management.

    EN 60950 - Safety of Information Technology Equipment safety standard.

    EN 55022 - EMC requirements on system level

    ANSI/IPC - A610 Rev.C Class 2 Manufacturing Requirements.

    3BK 20980 AAAA TQZZA Ed.07 17 / 112

  • 7/30/2019 BSC Disceription B9

    18/112

    1 Overview

    18 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    19/112

    2 Cabinet Description

    2 Cabinet Description

    Cabinet Description describes the Evolium A9130 BSC Evolution cabinet andthe required environmental conditions.

    3BK 20980 AAAA TQZZA Ed.07 19 / 112

  • 7/30/2019 BSC Disceription B9

    20/112

    2 Cabinet Description

    2.1 Layout and Facilities

    The Evolium A9130 BSC Evolution equipment is housed in a single 19standard rack. The rack provides:

    Mechanical housing for up to two ATCA shelves

    Connection of the secondary power supply, via duplicated -48V or -60V

    distribution, through a power distribution shelf called the JSXPDU

    Connection of the external links, essentially comprised of E1 interfaces and

    Giga Ethernet on balanced pairs

    Safety protection to industry standards.

    The following figure shows the layout of the cabinet.

    JSXPDU

    JSXATCA Shelf 4

    JSXATCA Shelf 3

    JSXLIU Shelf 1

    Plinth

    Cable

    Pipes

    JSXLIU Shelf 2

    Figure 3: Cabinet Layout

    The front door is 80% perforated (the maximum possible perforation for theallowed space).

    A 100 mm plinth is provided to allow site installation without opening theequipment, or to allow back cable entry on a concrete floor. Four levellingscrews provided to allow rack levelling.

    20 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    21/112

    2 Cabinet Description

    The front upright racking is welded 100 mm from the front door internal face toallow space for cables. The back racking upright position can be adjusted to fitthe depth of the ATCA shelves hosted in the cabinet.

    The top of the cabinet can be completely removed (including when cableentry is located at the top of the equipment) to allow easy access for on-sitecabling. It is reversible (front to back) to allow access from the left or right sides,depending on the configuration. For a corner installation, part of the installationkit is bolted to the racks using the ring hooks of the cabinet, therefore allowingthe use of a vertical cable guide.

    The following facilities are provided for site cabling:

    When cable entry is from the bottom, a rectangular pipe is installed on

    each side, between the front and the back upright racking, to easily allow

    14 power cables (14 mm in diameter ) to be fed from the bottom to the

    top (seven on each side)

    When cable entry is from the top, these pipes are used to feed 32 PCM

    cables (9 mm in diameter and equipped with a 12 x 66 mm connector) fromthe top to the bottom (16 on each side). In this case, up to six Ethernet

    cables (8 mm in diameter) can also be fed through these pipes.

    The bottom of the rack has three windows for bottom cable entry:

    One window at the front, covering the complete usable width of the

    JSXLIU/JSXLIUB shelf and dedicated principally to PCM cables access

    One window on each side, under the pipes, used for power cables routing in

    case of bottom access and for PCM cables routing in case of top access.

    3BK 20980 AAAA TQZZA Ed.07 21 / 112

  • 7/30/2019 BSC Disceription B9

    22/112

    2 Cabinet Description

    2.2 Hardware Architecture

    The following figure shows the hardware architecture of the Evolium A9130BSC Evolution.

    JBXSSW

    (duplicated)

    RadioNetworklinks

    External Ethernet Links

    JSXLIU Shelf(21 slots)

    E1

    JBXCCPn

    JBXMUX1

    JBXLIU1

    JBXLIU n

    ATCA Shelf (14 slots)

    JBXCCP

    JBXOMCP

    JBXOMCPr

    1

    w

    JBXTP

    JBXTPr

    w

    (duplicated)

    (duplicated)

    Figure 4: Evolium A9130 BSC Evolution Hardware Architecture

    The following table lists the functions provided by each functional block.

    Functional Block Function

    Gigabit Ethernet switch (JBXSSW) Allows exchanges between allplatform elements and externalIP/Ethernet equipment.

    O&M Control Processing board(JBXOMCP)

    Acts as system manager for the wholeplatform and for O&M applications.

    Call Control Processing board(JBXCCP)

    Controls the call functions for theplatform.

    Transmission Processing board(JBXTP)

    Provides telecomtransmission/transport interfaces tothe platform.

    Line Interface Unit (JSXLIU) shelf Multiplexes/demultiplexes and crossconnects all E1 external links to/fromNE multiplexed links (n E1 overEthernet) on the JBXTP board.Equipped with two JBXMUX boardsand n JBXLIU/JBLIU75 boards,

    depending on capacity.

    22 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    23/112

    2 Cabinet Description

    Functional Block Function

    JBXLIU/JBLIU75 boards (theinterface for radio network links)

    These links correspond to the userplane interfaces.

    Ethernet links on the IP ports of theJBXSSW switch These links connect the platform toexternal IP equipment (i.e. OMC-R,external alarm box).

    Table 3: Hardware Functions

    2.3 Dimensions and Weight

    The following table describes the cabinets external physical dimensions.

    Dimension Overall Size (mm)

    Height 2000 (including a 100 mm plinth)

    Width 600

    Depth 600

    Maximum weight 300 kg

    Table 4: Cabinet Dimensions and Weight

    2.4 Environment

    The equipment must not be exposed to extremes of temperature, or to relativehumidity. To meet the required environmental conditions, air conditioningequipment may have to be installed.

    The environmental conditions are:

    Temperature and humidity

    Atmospheric pressure

    Solar radiation

    Dust and particles

    Lighting

    Cooling

    Safety standards

    Green compliance.

    3BK 20980 AAAA TQZZA Ed.07 23 / 112

  • 7/30/2019 BSC Disceription B9

    24/112

    2 Cabinet Description

    2.4.1 Temperature and Humidity

    For altitudes between sea level and 500 meters, the temperature must bebetween + 5 C and + 40 C, within a relative humidity band of between 20 % to80 %. The temperature gradient must be less than 0.5 C per minute.

    Electrostatic DangerElectrostatics may cause minor shocks and/or damage to the equipment.The relative humidity must be at least 20 % at manned sites or duringmaintenance periods.Cooling, EMI conditions and noise emission are respected only if the doorsare closed during operation.

    2.4.2 Atmospheric Pressure

    For normal operation of the equipment, the atmospheric pressure must bebetween 65 kilopascals (kPa) and 120 kPa. Low pressure extremes must not

    be allowed to coincide with upper temperature limits.

    Note: An altitude of 3500 meters corresponds to a pressure of approximately 65.7kPa.

    2.4.3 Solar Radiation

    Direct Solar RadiationExposure to direct solar radiation may result in damage to equipment dueto overheating.Ensure that equipment is not subject to direct sunlight.

    2.4.4 Dust and Particles

    The equipment operates normally in the presence of solid (non-conductive,non-ferromagnetic, non-corrosive) particles. The following table lists themaximum sizes and concentrations of particles.

    Size of Particles(micrometers)

    Concentration(millions of particles per cubic meter)

    0.5 14

    1 0.7

    3 0.24

    5 0.13

    Table 5: Dust and/or Sand Particle Concentration Levels

    24 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    25/112

    2 Cabinet Description

    2.4.5 Lighting

    All optical signals, displays and labels are visible with an ambient light intensityof 800 lux.

    2.4.6 Cooling

    The Evolium A9130 BSC Evolution equipment uses forced air cooling.

    2.4.7 Green Compliance

    The Evolium A9130 BSC Evolution cabinet complies with the new Europeandirectives concerning the environment:

    Wastes of Electrical and Electronic Equipment (WEEE)The requirements for re-use and recycling capabilities are applicable to thecomplete A9130 BSC product line (not only for the cabinet).

    Restriction of Hazardous Substances (RoHS).

    3BK 20980 AAAA TQZZA Ed.07 25 / 112

  • 7/30/2019 BSC Disceription B9

    26/112

    2 Cabinet Description

    26 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    27/112

    3 Power System

    3 Power System

    Power System describes the power distribution system of the Evolium A9130BSC Evolution.

    3BK 20980 AAAA TQZZA Ed.07 27 / 112

  • 7/30/2019 BSC Disceription B9

    28/112

    3 Power System

    3.1 Power Distribution Unit

    3.1.1 Introduction

    The new generation of BSC equipment referred to as A9130 BSC Evolution is

    housed in a single 19 standard rack called the JRXCAB. Power distributioninside this cabinet is handled by the Power Distribution Unit (JSXPDU) shelf,which provides:

    Connection to a duplicated secondary -48V or -60V power supply

    distribution, through 35 mm2 double skin cables

    Breakers and power supply distribution to ATCA shelves (75A each) and

    JSXLIU/JSXLIUB shelves (10A each)

    Safety protection to industry standards.

    In order to supply the two JSXATCA shelves and the two JSXLIU/JSXLIUB

    shelves of an A9130 BSC cabinet, the JSXPDU shelf meets the followingexternal requirements:

    19 standard shelf

    Connection to the power plant via 12 double skin 35mm2

    cables, with

    an overall diameter of 14mm each

    Connection to the loads via 24 x 16 mm2

    cables with an overall diameter

    of 7mm each

    Connection to ground via one double skin 35mm2

    cable with an overall

    diameter of 14 mm

    Cabling access from the top back part of the equipment

    Paint color according to Alcatel standards

    The front panel is covered by a light grey label (the other face is not painted)

    EMC shielding is not required (no active part)

    Earthquake protection

    Fire protection

    Compliance with the new European directives concerning the environment

    Meets the RoHS and WEEE requirements

    Safety protection is provided via two independent covers.

    28 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    29/112

    3 Power System

    3.1.2 Mechanical Characteristics

    The JSXPDU is a standard 19 shelf, 2U in height. The racking brackets aremounted 60 mm behind the front panel. The overall depth is approximately250 mm.

    3.1.3 Schematic

    The JSXPDU consists of two independent branches, the BATA and BATB.

    Each branch of the JSXPDU shelf is composed of three independentdistribution systems, independently powered by two 35 mm2 wires with doubleskin insulation:

    Each distribution system (1 or 2) includes:

    One 75A breaker with two outputs

    One 10A breaker with one output.

    Each distribution system includes one 75A breaker and two outputs.

    Each branch comprises:

    Three 75A breakers, to supply up to two ATCA shelves. The third 75A

    breaker is equipped for future use.

    Two 10A breakers, to supply up to two JSXLIU/JSXLIUB shelves.

    BATA 1

    BATaR 1

    BATA 2

    BATaR 2

    BATA 3

    BATbR 1

    ATCAshelf3

    BATB 2

    BATbR 2

    BATB 3

    BATbR 3

    A3 A4 A5 B5

    ATCAs

    he

    lf2

    ATCAs

    he

    lf1

    LIU

    she

    lf1

    ATCAs

    he

    lf3

    LIU

    shelf2

    BATaR 3

    Branch A

    BATB 1

    ATCAs

    he

    lf2

    ATCAs

    he

    lf1

    LIU

    she

    lf1

    LIU

    she

    lf2

    A1 A2 B1 B2 B3 B4

    Branch B

    Figure 5: JSXPDU Overview

    3.1.4 Power Station Connection

    Connection to the power station is via two or more 35 mm2

    double skin wiresper ATCA shelf and per branch. The JSXPDU therefore provides connection tothe power station via 12 x 14mm power cables and one 14mm ground cable.

    3BK 20980 AAAA TQZZA Ed.07 29 / 112

  • 7/30/2019 BSC Disceription B9

    30/112

    3 Power System

    3.1.5 Connection to the Hosted Shelves

    Each ATCA shelf is connected to the JSXPDU via eight 16 mm 2 wires (7mm indiameter).

    Each JSXLIU/JSXLIUB shelf is connected to the JSXPDU by two 7 mm (three1.5 mm2 wires ) cords, including the ground.

    3.1.6 Earthing Connection

    The buildings ground is connected to the JSXPDU by a double stud. Thisearthing conductor is distributed to the JSXLIU/JSXLIUB shelves through thepower cord, and to the mechanics of the cabinet via a double stud. A specificlabel is added near the connection of the earthing conductor.

    3.1.7 Safety

    The JSXPDU meets the EN 60950 safety standards. Branch A and branch B arebe independently protected by two separate covers so that service personnel

    can safely access one power branch when the other branch is operational.

    3.1.8 Provision for Future Use

    In the case where an alarm function will be added in the JSXPDU, a free spaceof approximately 25 mm width of the whole height (2U) is reserved betweenboth branches A and B. The front plate is bored with a column of five 4mmholes. These holes will be hidden by the label which covers the whole frontpanel and bears the marking.

    3.1.9 JSXPDU Front View

    The following figure shows the front view of the JSXPDU.

    I

    O

    I

    O

    I

    O

    I

    O

    I

    O

    I

    O

    I

    O

    I

    O

    I

    O

    I

    O

    B1 B2 B3 B4 B5A2 A3 A4 A5A1

    Shelf 4 Shelf 2 Shelf 3 Shelf 1 Shelf 4 Shelf 2 Shelf 3 Shelf 1

    Figure 6: JSXPDU Front View and Marking

    3.1.10 Power Distribution Cable Characteristics3.1.10.1 ATCA Shelves Supplying

    The power entry on ATCA shelves is done via 6 mm studs. The power cablescoming from the JSXPDU shelf are terminated by lugs rings.

    The cable used is a two wire, 16 mm2 cable. The blue wire corresponds toVBAT. The black marked wire corresponds to the Battery Return.

    The required cable lengths are:

    1.5 m for the upper ATCA shelf

    2.1m for the second ACTA shelf.

    30 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    31/112

    3 Power System

    3.1.10.2 ATCA Shelf Grounding

    The ATCA grounding point is a double lug, spaced at 19 mm. The 16mm2

    yellow/green ground cable is terminated by a lug with two holes.

    There are two possibilities for the ground connection:

    One cable between each ATCA shelf and the JSXPDU (same length aspower cable), or

    The frame of the cabinet is used as ground, and the JSXPDU and the ATCA

    shelves are connected to the frame by a cable.

    3.1.10.3 JSXLIU/JSXLIUB Shelf Supply and Grounding

    The power connection on the JSXLIU/JSXLIUB shelves is done through threepin UP connectors. The connector is composed of a moulding and threecontacts.

    3.2 CoolingThe JSXATCA shelf provides fault tolerant cooling to front mounted AdvancedTelecom Computing Architecture (Advanced TCA) blades, and to rear transitionmodules based on four front-maintainable, intelligent fan trays, with one fanper tray.

    Blower trays are mounted in the shelf top. The following figure shows thegeneral airflow for the ATCA system. The cooling type is front to rear.

    Air Inlet

    Air Outlet

    Front Rear

    Blowers

    Figure 7: Shelf Airflow

    The cooling system is designed to manage a heat dissipation of 200W perfront slot and an additional 20-30W per rear slot.

    Each of the fan tray units contains an IPMC, which is located on both theIPMB-A and IPMB-B buses. Individual fan failures are detected by monitoringthe fan rotation speed. Rotation which is 15% below demand is deemed to be a

    fan failure. Usually the cooling system runs the fans at 40%. In the case of a

    3BK 20980 AAAA TQZZA Ed.07 31 / 112

  • 7/30/2019 BSC Disceription B9

    32/112

    3 Power System

    single fan failure, the fans run at 100% to still provide full air pressure within thearea between the fans and the boards.

    Each fan tray monitors and reports air temperature and failure conditions to theshelf manager. The shelf manager controls the fan speed based on sensorand failure information acquired from the fan and board sensors. If a fantray looses IPMI communication with the shelf manager, it will automaticallyrun the fans at full speed.

    The following figure shows the block diagrams with the main componentsof the blower.

    Bl

    ow

    erP

    CB

    Tach

    PWM

    LEDs

    Hot Swap Switch

    Flame Sensor

    RiCool 2Controller

    Con

    trol

    I

    nterfac

    e

    Flame Sensor

    HA

    Enables

    IPMC Bus 1

    IPMC Bus 2

    48 A

    48 B

    + V_A

    + V_B

    Figure 8: Block Diagram of a Blower

    JSXLIU/JSXLIUB shelf cooling is managed by natural convection.

    32 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    33/112

    4 ATCA Shelf

    4 ATCA Shelf

    This section describes the ATCA shelf and its components.

    3BK 20980 AAAA TQZZA Ed.07 33 / 112

  • 7/30/2019 BSC Disceription B9

    34/112

    4 ATCA Shelf

    4.1 ATCA Shelf Description

    The ATCA shelf is designed for "five nines" uptime (99.999%).

    The shelf provides 14 slots which can be equipped with Advanced TCA bladesand corresponding Rear Transition Modules (RTM) at the rear of the system.

    The 14 slots are typically set up as two hub slots and 12 node slots.This is shown in the following figure.

    Fan Trays

    Air Inlet

    Figure 9: ATCA Shelf

    The system is always equipped with:

    A dual star backplane providing connector interfaces for power distribution,

    input/output connectivity between front blades, and mechanical alignment

    and support

    A backplane with base and fabric interface

    A subrack providing attachment points for the backplane, alignment and

    support, and a mechanical engagement for insertion and extraction of

    the front blades and RTMs

    Two JAXSMM shelf manager boards. Each blade and Field Replaceable

    Unit (FRU) provides links to the shelf manager through an Intelligent

    Platform Management Bus (IPMB)

    12 node slots which can be equipped with Advanced TCA node blades

    Two hub slots which can be equipped with Advanced TCA hub blades

    14 slots at the systems rear side which can be populated with 14 RTMs.

    These RTM connections provide user defined input and output connectivity

    to the corresponding front blades

    Four IPMC-enabled intelligent blowers

    Four single entry DC Feed intelligent JBXPSs with 90 Amp / 50 Amp

    breakers and line filters

    Two alarm boards

    34 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    35/112

    4 ATCA Shelf

    An air filter

    Rear ESD wrist strap sockets and grounding studs.

    The following figures show the ATCA subrack front and back views.

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    Air inlet

    CLOSED / OPEN H/S OOS

    CLOSED / OPEN H/S OOS

    CLOSED / OPEN H/S OOS

    CLOSED / OPEN H/S OOS

    JBXSSW

    JBXTP

    JBXCCP

    JBXOMCP

    JBXTP

    NotUsed

    NotUsed

    NotUsed

    NotUsed

    JBXCCP

    JBXCCP

    JBXCCP

    JBXOMCP

    JBXSSW

    Figure 10: ATCA Subrack Front View

    (POWER)

    +(RETURN)

    (POWER)

    +(RETURN)

    (POWER)

    +(RETURN)

    (POWER)

    +(RETURN)

    ATCAM100

    OOS

    OK

    ACT

    H/S

    ATCAM100

    OOS

    OK

    ACT

    H/S

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2

    Air outlet

    GND

    JAXPC

    JAXPC

    JAXSMMJBXPS

    JAXSMM

    Open

    Closed

    OOS

    OK

    Handle

    H/S

    Alarm/Reset

    TelcoAlarms&Relays

    JAXPC

    Open

    Closed

    OOS

    OK

    Handle

    H/S

    Alarm/Reset

    TelcoAlarms&

    Relays

    JAXPC

    JBXPS JBXPS JBXPS

    Figure 11: ATCA Subrack Back View

    3BK 20980 AAAA TQZZA Ed.07 35 / 112

  • 7/30/2019 BSC Disceription B9

    36/112

    4 ATCA Shelf

    4.1.1 Shelf

    The 13U (577 mm) and 440 mm deep shelf for 19" racks is made of stainlesssteel.

    There is one mounting bracket on each side of the shelf, designed forfront-mounting the shelf into a rack.

    The system can be installed in a standard 19 rack.

    4.1.2 Node Slots

    The node slots are equipped with Advanced TCA blades.

    Advanced TCA blades used in BSC configuration are the followinghigh-performance, single slot, hot-swap node boards:

    JBXOMCP

    JBXSSW.

    Advanced TCA blades offer a high processing performance. They are idealfor telecommunication applications.

    4.1.3 Hub Slots

    The hub slots are equipped with JBXSSW switches. The JBXSSW is a GigabitEthernet switch.

    4.1.4 Rear Transition Modules

    The Advanced TCA blades can be connected to Rear Transition Modules(RTM) to provide easy access to I/O signals through the zone 3 connector

    defined by the Advanced TCA specifications.

    RTMs can be used as a rear expansion board for the JBXSSW switch to accessthe different interfaces on an AdvancedTCA blade through the JAXSSWfront plate.

    4.1.5 Power Entry Modules

    Four field hot-swap intelligent JBXPSs with a 50 Amp breaker and line filterare installed beneath the rear slots of the backplane. The four JBXPSs areused to provide split power distribution. For details about the JBXPS refer toJBXPS (Section 4.8)

    4.1.6 Power Distribution System

    The shelf has two different power distribution systems that run throughout theshelf. The first is a low power (3.4VVDC) system that provides power to all ofthe IPMCs. The second is a high power (-48VDC) system that provides powerto all of the blades, blowers and shelf managers.

    36 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    37/112

    4 ATCA Shelf

    4.1.6.1 Low Power Distribution System

    The shelfs low power distribution system powers the IPMCs engines. Thislow power source (3.4V DC) manifests itself in the form of a redundantinterconnect. The first (V_A) is sourced from the JAXSMM in the J3 location.The second (V_B) is sourced from the JAXSMM in the J11 location. The IPMCsare expected to OR the two sources to allow for redundancy. Current on eachsource is limited by the 2 mm connector to approximately 1.5 A.

    The inclusion of the low power distribution system is to allow for powering theIPMCs without having to include an isolated DC-DC and all of its relatedcircuitry in each IPMC. This is most useful in FRUs such as the blowers andJAXPCs, where their size essentially prohibits the inclusion of such powerconversion circuitry.

    The voltage from the power distribution system can also be found on theoptional IPMC expansion connectors found throughout the shelf.

    The following figure shows the low power distribution system found in theJBXPS shelf.

    J

    BXSSW

    JAXSMM

    JBXFAN

    JBXPS2B1

    JBXPS3A2

    JBXPS1A1

    1 2 3 4 5 6 9 10 11 12 13 14 7 8

    JBXPS4B2

    Physical Slot

    JBXOMCP

    JBXOMCP

    J

    BXSSW

    JAXSMM

    JAXPC

    JAXPC

    JBXFAN

    JBXFAN

    JBXFAN

    Figure 12: Shelf Low Power Distribution System

    3BK 20980 AAAA TQZZA Ed.07 37 / 112

  • 7/30/2019 BSC Disceription B9

    38/112

    4 ATCA Shelf

    4.1.6.2 High Power Distribution System

    The shelfs high power distribution system is for powering the blade, JAXSMMsand blowers. This high power source (-48V DC - nominal) manifests itself inthe form of one or two sets of redundant interconnects. The JBXPS shelf hastwo set of redundant interconnects.

    The following figure shows the high power distribution system.

    J

    BXSSW

    JAXSMM

    JAXPC

    JBXFAN

    JBXPS2B1

    JBXPS3A2

    JBXPS1A1

    1 2 3 4 5 6 9 10 11 12 13 14 7 8

    JBXPS4B2

    Outside the chassis

    Batterylant A

    Batteryplant B

    Physical Slot

    J

    BXOMCP

    J

    BXOMCP

    J

    BXSSW

    JAXSMM

    JAXPC

    JBXFAN

    JBXFAN

    JBXFAN

    Figure 13: Shelf High Power Distribution System

    The first redundant interconnect is made up of the A1 and B1 feeds. The firstfeed (-48V_A1) is sourced from the A1 JBXPS in the far left (as viewed from therear of the shelf). The second feed (-48V_B1) is sourced from the B1 JBXPS to

    the right of the first one. Both feeds are individually routed to each JAXSMM,

    38 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    39/112

    4 ATCA Shelf

    blower and odd numbered slots. The second redundant interconnect is madeup of the A2 and B2 feeds. The third feed (-48V_A2) is sourced from the A2JBXPS (to the right of the B1 JBXPS). The fourth feed (-48V_B2) is sourcedfrom the B2 JBXPS (to the right of the A2 JBXPS). These feeds only route tothe even numbered slots. In both interconnects, the FRUs are expected to ORthe two sources to allow for redundancy.

    The A1 and B1 JBXPS locations are capable of supplying 90 A of current,although the JBXPSs will only allow for 50 A. The A2 and B2 JBXPS locationsare capable of supplying 50 A. This allows for a single JBXPS in eachinterconnect, to support the full power requirement of the interconnect.

    For the blowers, the A1 and B1 feeds are capable of supplying 12 A whenderated for a 30 C temperature rise. For the JAXSMMs, the A1 and B1 feedsare limited by the 2 mm connector to approximately 1.5 A (per feed).

    4.1.7 Blowers

    The system provides fault-tolerant cooling by using four front accessible,

    hot-swap intelligent fan trays. Each fan tray contains one blower with built-inspeed control. A toggle switch is provided to allow supervision interruptionfor maintenance reasons.

    4.1.8 Shelf Manager

    The shelf manager (JAXSMM) is designed to be used in Advanced TCAsystems. It is the central management unit of the shelf. It monitors, controlsand ensures the proper operation of the shelf and all other components ofthe Advanced TCA shelf.

    It reports anomalies and errors and takes corrective actions if required (e.g.increases the speed of the blowers). The JAXSMM has access to detailed

    inventory information as well as to sensor status information concerning theshelf and all the components of the shelf.

    4.1.9 Personality Card

    The personality card (JAXPC) is a shelf configuration and alarm board usedwith AdvancedTCA systems. The JAXPC personality card is designed for rearaccess applications. It is located below the Rear Transition Module (RTM) area.

    4.1.10 Air Filter

    The air filter is located in the lower part of the shelf. It ensures that the shelfoperates properly. Regular cleaning and replacement is mandatory.

    3BK 20980 AAAA TQZZA Ed.07 39 / 112

  • 7/30/2019 BSC Disceription B9

    40/112

    4 ATCA Shelf

    4.1.11 Backplane

    The backplane provides the following features:

    Two hub slots

    12 node slots

    14-slot fabric interface with a dual star interconnect

    A base interface with a dual star interconnect

    An update interface between physical adjacent slots

    A base interface to the shelf manager slots

    Bused IPMB-0 connections

    Synchronization of clock buses.

    4.1.12 Distribution BoardThe distribution board has the following features:

    Power lugs and studs for power transfer to the backplane

    Blower interface

    Interface for two shelf manager boards

    Support for up to four JBXPSs

    Interfaces for two JAXPC personality cards (Telco I/O).

    4.1.13 Mechanical DataThe following table describes the dimensions and the weight of the system.

    Measurement Value

    Height 577 mm (13U)

    Width 438 mm (14 x 6HP)

    Rack mounting 482.6 mm (19)

    Depth from rack mounting pane Top: Towards the front 60 mm in theblower area

    Middle: The wiring area is compliantwith PICMG 3.0

    Bottom: Towards the rear 415 mm inthe JBXPS area

    Weight 38kg (Without ATCA blades andRTMs)

    40 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    41/112

    4 ATCA Shelf

    4.2 JBXOMCP/JBXCCP

    4.2.1 Introduction

    The JBXOMCP/JBXCCP is an Advanced TCA compliant single board computer

    offering high processing performance. Four on-board PMC sites, a redundantGBit Ethernet connection to the ATCA Base interface and standard I/Ointerfaces make it ideal for telecommunication and datacom applications.

    It provides the following features:

    A Pentium M processor with up to 1.8 GHz speed

    Up to 4 GByte main memory SDRAM with ECC protection

    Redundant ATCA Base interface

    Two USB 2.0 interfaces on the front plate

    60 GByte hard disk (available only on JBXOMCP boards)

    Support for Carrier Grade Linux Ed. 3.1

    On-board IPMC compliant to IPMI V.1.5 with redundant IPMB support

    Different Rear Transition Modules (RTM) available separately

    A CMC module providing two serial interfaces on the front plate.

    3BK 20980 AAAA TQZZA Ed.07 41 / 112

  • 7/30/2019 BSC Disceription B9

    42/112

    4 ATCA Shelf

    4.2.2 Front Plate

    The following figure shows the connectors, keys and LEDs available on thefront plate.

    PMC1

    RESET

    P

    M

    C

    2

    PMC3

    PMC4

    oos

    OK

    ACT

    HDD

    H/

    S

    USB1

    USB2

    Figure 14: JBXOMCP/JBXCCP Front Plate

    42 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    43/112

    4 ATCA Shelf

    4.2.3 LEDs

    The following figure shows all LEDs available on the front plate.

    P

    M

    C2

    oo

    s

    OK

    ACT

    H

    DD

    H/

    S

    Figure 15: Location of Front Plate LEDs

    The following table describes the JBXOMCP/JBXCCP LEDs.

    LED Description

    OOS Out Of Service

    Red: The blade is out of service

    OFF: The blade is working properly

    OK Power status

    Green: Supply voltages are within threshold values

    OFF: Supply voltages are outside threshold values

    ACT Redundancy status

    Amber: The blade is active

    OFF: The blade is stand-by

    3BK 20980 AAAA TQZZA Ed.07 43 / 112

  • 7/30/2019 BSC Disceription B9

    44/112

    4 ATCA Shelf

    LED Description

    HDD During booting this LED indicates the boot status. Laterit indicates the combined parallel/serial ATA activity or isused as user LED. Toggling between both modes is done

    via the LED control register.In user mode:

    Depending on the FPGA LED control register, the LEDis either red, green or OFF.

    In parallel/serial ATA activity mode:

    Red: Combined activity of parallel and serial ATAinterfaces.

    OFF: No activity.

    H/S Hot swap

    During blade installation:

    Permanently blue: On-board IPMC powers up

    Blinking blue: Blade communicates with the ShelfManagement controller

    OFF: Blade is active

    During blade removal:

    Blinking blue: Blade notifies the Shelf Managementcontroller of its desire to deactivate.

    Permanently blue: Blade is ready to be extracted.

    44 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    45/112

    4 ATCA Shelf

    4.2.4 Keys

    The blade provides one front plate reset key. This is shown in the followingfigure.

    R

    E

    S

    E

    T

    P

    MC3

    H

    /

    S

    Figure 16: Location of Reset Key

    On pressing the reset key, a hard reset is triggered and all attached on-boarddevices are reset.

    Note: The IPMC is not reset via this key.

    4.2.5 Connectors

    4.2.5.1 Front Plate ConnectorsThe blade provides two mini USB 2.0 connectors (type AB) on its front plate.They correspond to the USB interfaces 1 and 2. These interfaces are notused for BSC application.

    This is shown in the following figure.

    P

    M

    C

    2

    ACT

    HD

    D

    U

    SB1

    U

    SB2

    Figure 17: Location of USB Connectors

    3BK 20980 AAAA TQZZA Ed.07 45 / 112

  • 7/30/2019 BSC Disceription B9

    46/112

    4 ATCA Shelf

    4.2.5.2 On-Board Connectors

    The blade provides the following on-board connectors:

    CompactFlash

    PMC

    Parallel ATA

    Serial ATA

    CMC

    ATCA backplane connectors.

    4.2.5.3 ATCA Backplane Connectors

    The ATCA backplane connectors reside in zones 1 to 3, as specified in theATCA standards.

    The connector located in zone 1 is used to draw power from the backplane.

    Zone 2 contains the 3 connectors P20, P21 and P23. P20 is used to supporttelephony clocking. P21 and P23 are used to connect the blade to the standardATCA interfaces. All these connectors are standard and therefore are notdocumented in this guide.

    Zone 3 contains the 3 connectors P30 to P32. They are used to connect anRTM to the blade and carry the following signals:

    Serial (RS232)

    Serial ATA

    USB

    Keyboard/Mouse

    IPMI

    Power

    PMC user I/O.

    In case of BSC application only the JBXSSW blades use the RTM.

    46 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    47/112

    4 ATCA Shelf

    4.3 JBXSSW

    4.3.1 Introduction

    The blade provides the following features:

    Advanced TCA compliant switch

    Managed 24-port Layer 2 Gigabit switch for the base interface

    Gigabit Ethernet support for 14 payload slots

    Eight base and one fabric Gigabit Ethernet uplinks via the rear transition

    module

    16-port Layer 2 Gigabit Ethernet switch for the fabric interface

    ATCA Management Controller (IPMI version 1.5) which communicates

    with Shelf Management controllers

    SNMP agent for switch management

    Option for TDM clock generation and synchronization via CGM module

    Designed for NEBS level 3 and ETSI requirements.

    The fabric interface and clock generation and synchronization module are notused for BSC application.

    The following figure shows the main function blocks of the blade.

    BootFlash

    Processor

    RTC

    Power Module

    CompactFlashCard

    FabricInterfaceSwitch

    BaseInterfaceSwitch

    BaseInterfaceSwitch

    PMC Slot forClock

    GenerationModule

    Figure 18: Blade Functional Blocks

    3BK 20980 AAAA TQZZA Ed.07 47 / 112

  • 7/30/2019 BSC Disceription B9

    48/112

    4 ATCA Shelf

    4.3.2 Front Plate

    The following figure shows:

    Position of the Ethernet interface

    LEDs

    Reset key

    Serial interface on the front plate.

    OOS

    OK

    ACT

    PM

    C

    I

    NTERF

    ACE

    FABRI

    C

    I

    NTERFACE

    BASE

    1

    2

    3

    4

    5

    1

    2

    3

    4

    5

    6

    7

    8

    ABC

    S

    ABC

    ETH2

    RESETH/S

    ST

    SERI

    AL

    ETH1

    L A

    Figure 19: JBXSSW Front Plate

    48 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    49/112

    4 ATCA Shelf

    4.3.3 LEDs

    The following LEDs are available on the front plate:

    Status and Ethernet LEDs

    Base interface LEDs.

    4.3.3.1 Status and Ethernet LEDs

    The following figure shows the location of the status and Ethernet LEDs.

    OOS

    OK

    ACT

    SLA

    ABC

    ETH2

    RESETH/S

    ST

    SERI

    AL

    ETH1

    Figure 20: JBXSSW LED Location

    3BK 20980 AAAA TQZZA Ed.07 49 / 112

  • 7/30/2019 BSC Disceription B9

    50/112

    4 ATCA Shelf

    The following table describes the LEDs.

    Name Color Description

    OOS Red Out Of Service

    Red: The blade is out of serviceOFF: The blade is working properly

    OK Green Power OK

    Green: The blade is operating properly

    OFF: Otherwise

    ACT Amber Active

    Amber: The blade is active

    OFF: The blade is in standby mode

    H/S Blue Blue: The blade is ready to be extracted

    Blinking: The blade communicates with theJAXSMM during insertion or notifies its requestto deactivate during extraction.

    OFF: The blade is not ready to be extracted.Do not remove the board during this state.

    ETH2 S - Speed Green

    Orange

    10 BaseT

    100 Base Tx

    ETH2 L - Link Green ON: Link up

    OFF: Link down

    ETH2 A - Activity Orange ON: Activity

    OFF: No activity

    During power-up

    ST A Red

    Green

    Power good 3

    FPGA initialized

    ST B Red

    Green

    Power good 2

    Power good of all DC/DCs

    ST C Red

    Green

    Orange

    Power good 1

    Power up command from IPMC

    Power good 1 and power up command fromIPMC are indicated

    During operation

    50 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    51/112

    4 ATCA Shelf

    Name Color Description

    ST A Indicates general activity via UART betweenboth boards:

    GreenOrange

    No activityActivity

    ST B Indicates the status at the Ethernet heartbeatconnection:

    Red

    Green

    Orange

    Heartbeat connection is dead

    Active

    Warning

    ST C Indicates the status at the UART heartbeat

    connection:

    Red

    Green

    Orange

    Heartbeat connection is dead

    Active

    Warning

    Table 6: JBXSSW LED Description

    4.3.3.2 Base Interface (BIF) LEDs

    There is one LED per physical port, located on the front plate.

    This is shown in the following figure.

    B

    AS

    E

    1

    2

    3

    4

    5

    6

    7

    8

    I

    NTERF

    ACE

    Figure 21: Base Interface LED Location

    The following table describes the LEDs.

    3BK 20980 AAAA TQZZA Ed.07 51 / 112

  • 7/30/2019 BSC Disceription B9

    52/112

    4 ATCA Shelf

    Color Description

    Green Port-performed linkup but no activity

    Orange Port-performed linkup and there is

    activity

    Table 7: Color Coding of Base Interface LEDs

    The following table describes the mapping of the physical port to the frontplate LEDs.

    LED Interface/Port

    (BIF)

    LED Interface/Port

    (BIF)

    LED Interface/Port

    (RTM)

    A1 1 B1 9 C1 17

    A2 2 B2 10 C2 18

    A3 3 B3 11 C3 19

    A4 4 B4 12 C4 20

    A5 5 B5 13 C5 21

    A6 6 B6 14 C6 22

    A7 7 B7 15 C7 23

    A8 8 B8 16 C8 24

    Table 8: Base Interface and RTM LEDs

    4.3.4 Connectors

    The front plate provides the following connectors:

    RJ-45, which is used for debugging only

    Serial, which is used for factory settings.

    52 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    53/112

    4 ATCA Shelf

    SLA

    ETH2RESET

    H/S

    SERI

    AL

    ETH1

    Figure 22: Connector Location

    4.3.5 Reset Key

    The front plate provides one mechanical reset key. This is shown in thefollowing figure.

    SLA

    ETH2

    RESETH/S

    SERI

    AL

    Figure 23: Reset Key Location

    A reset of all on-board I/O devices and the CPU is performed when the resetkey is set to the active position. The reset is maintained until the key is returnedto the inactive position, however at least 200 ms are guaranteed by a local timer.

    4.3.6 BackplaneThe backplane provides the following connectors:

    Zone 1: power connectorZone 1 connectors are used to implement the power supply interface.

    Zone 2: data transport interfaceZone 2 connectors are used to implement the base and fabric interface.

    Zone 3: access to RTM.The Zone 3 connectors provide access to the JAXSSW rear transitionmodule.

    3BK 20980 AAAA TQZZA Ed.07 53 / 112

  • 7/30/2019 BSC Disceription B9

    54/112

    4 ATCA Shelf

    4.4 JAXSSW

    4.4.1 Front Plate

    The following figure shows the front plate of the blade.

    E

    T 1

    H

    OOSOK

    ACT

    HS

    E

    T 2HE

    T 3HE

    T 4

    HE

    T 5HE

    T 6HE

    T 7HE

    T 8H

    Figure 24: Front Plate

    54 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    55/112

    4 ATCA Shelf

    4.4.2 LEDs

    The RTM provides four LEDs on the front plate, as shown in the following figure.

    All LEDs are standard ATCA LEDs.

    OOS

    OK

    A

    CT

    ET 3H

    E

    T 4H

    E

    T 5H

    E

    T 6H

    HS

    Figure 25: JAXSSW Front Plate LEDs

    The following table describes the LEDs.

    LED Description

    OOS Out Of Service

    Red: The blade is out of service

    OFF: The blade is working properly

    OK Power OK

    Green: The blade is operatingproperly

    OFF: Otherwise

    3BK 20980 AAAA TQZZA Ed.07 55 / 112

  • 7/30/2019 BSC Disceription B9

    56/112

    4 ATCA Shelf

    LED Description

    ACT Not used

    H/S Hot Swap

    Blue: The blade is ready to beextracted

    OFF: The blade is not ready to beextracted. Do not remove the boardduring this state.

    Table 9: Front Plate LED Description

    4.4.3 Ethernet Uplink Connectors

    The JAXSSW provides eight Ethernet uplink connectors (ETH1 to ETH8) onthe front plate. ETH1 to ETH8 are routed to the base channel switch located onthe JBXSSW, and provide access to the shelfs base channel interfaces.

    ETH1 to ETH8 are available as RJ-45 connectors and constitute10/100/1000BaseTX interfaces.

    For Ethernet uplink connectors location refer to Figure 24.

    56 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    57/112

    4 ATCA Shelf

    4.5 JBXTP

    4.5.1 Introduction

    The JBXTP board is located in the BSC. Together with the BTS, it performs the

    radio-related functions in the BSS.These features are implemented on a centralized JBXTP board, working in 1+1redundancy, and ensure the following main functions:

    Handling of up to 252 E1 or 4 x STM-1 (STM1 interfaces will be provided in

    a future release with a daughter board)

    E1 framing and supervision

    TDM bit-switching (n x 8 kbps)

    HDLC, SS7, QMUX, Ring Control, Ater alarm (Alarm Octet) handling

    NE1oE function for up to 252 E1.

    The following figure shows the global architecture for the BSC.

    JBXTPW

    JBXCCP1

    JBXCCPP

    JBXTPP

    JBXCCPN

    JBXSSWW

    JBXSSWP

    JBXOMCP

    W

    JBXOMCP P

    E1 Termination Shelf

    External E1 Links O&M + TELECOM

    NE1oE

    1 Gigabit Ethernet ATCA Base Interface

    Figure 26: BSC Global Architecture

    4.5.2 Architecture

    The JBXTP board can be split into the following functional modules:

    OBC module

    HDLC, SS7, QMUX, R/W bits termination module

    Bit switch module

    E1 framer module

    Ethernet switch module

    NE1OE module

    3BK 20980 AAAA TQZZA Ed.07 57 / 112

  • 7/30/2019 BSC Disceription B9

    58/112

    4 ATCA Shelf

    STM1 daughter board (Optional)

    Clock module

    IPMC module

    Reset module

    Power supply module.

    4.5.2.1 OBC Module

    The OBC module supports all the processing for the JBXTP.

    4.5.2.2 HDLC, SS7, QMUX, R/W Bits Termination Module

    The module provides the following features:

    Handling of the LAPD and PPP layers related to the GSM protocols between

    the BTS, BSC and MSC equipment

    Handling of the MTP1 and MTP2 layers of the SS7 protocol between theBSC and the MSC

    Handling of the Qmux proprietary asynchronous transmission protocol

    used for communication between the TSC function (OMCP) and remote

    Network Elements (BTS)

    R/W bits handling related to Ring Control and the Ater Alarm (Alarm Octet).

    This function is handled in the TBS.

    4.5.2.3 Bit Switch Module

    The module implements the N x 8kbps synchronous switch which interconnects

    the 2.048Mbps links of the Ater or Abis interfaces and the termination modules(Q1, HDLC, R/W and SS7).

    It is a 72448-subchannel (8kbps) x 72448-subchannel (8kbps) non blockingunidirectional switch with the following interconnections:

    252 x 2.048Mbps links for the Ater or Abis interfaces

    16 x 2.048Mbps links for HDLC

    Two 2.048Mbps links for the SS7 signalling

    Three 2.048Mbps links for the QMUX

    10 x 2.048Mbps links for the R/W bits.

    4.5.2.4 E1 Framer Module

    This module includes:

    Four 63 E1 framers terminating up to 252 E1links

    Eight ESD FPGAs to perform the adaptation between the Data + Clock line

    interfaces of the framers and the two 16 serial links of the NE1oE module.

    4.5.2.5 Ethernet Switch Module

    Based on the single-chip, eight-port Gigabit switch, this module interconnects

    the Ethernet ports of the OBC, the NE1oE module of the baseboard, and the

    58 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    59/112

    4 ATCA Shelf

    NE1oE module of the STM1 optional daughter board with the backplaneBase Interfaces.

    4.5.2.6 NE1OE Module

    The nE1 over Ethernet module provides the transport of the E1 links payloadover a Giga Ethernet link between the LIU shelf (256 E1) and the JBXTP

    board coming through the SSW Ethernet switch boards and the standard1000-BaseT Base interfaces.

    4.5.2.7 STM1 Daughter Board (Optional)

    The JBXTP provides a PMC site for an STM1 daughter board.

    The power consumption budget allocated to the STM1 daughter board is 25W,and generally supports the following distribution:

    4A on 3.3V.

    0,8A on 2.5V

    6.4A on 1.5V.

    4.5.2.8 Clock Module

    This module gathers the clock functions related to the following domains:

    PCI bus

    PDH

    NE1oE

    Local Ethernet switch

    IMPC.

    4.5.2.9 IPMC Module

    All Advanced TCA boards support an intelligent hardware management system,based on the "Intelligent Platform Management Interface Specification". Thehardware management system provides the ability to manage power andinterconnect requirements for intelligent devices, to monitor events and tolog events to a central repository.

    The IPMC module manages:

    Communication with the shelf managers via the two IPMB interfaces

    The FRU state of the JBXTP board

    The blue LED and the handle switch state for the hot-swap

    The power-ON and power-OFF sequences of the payload

    The FRU RI EEPROM.

    3BK 20980 AAAA TQZZA Ed.07 59 / 112

  • 7/30/2019 BSC Disceription B9

    60/112

    4 ATCA Shelf

    4.5.2.10 Reset Module

    The logic reset of the JBXTP board resides in the EPLD.

    In addition, this EPLD:

    Handles the access to the registers of the Ethernet switch through the

    SPI bus from the local bus

    Can ask to the CLU FPGA to start the FPGA downloading and retrieve the

    downloading status when completed

    Also controls the ATCA application LEDs on the front panel.

    4.5.2.11 Power Supply Module

    The power supply module provides the secondary power supply for the overallboard. On-board DC/DC converters and regulators provide the necessarypower supply to the board from two -48V DC redundant primary feeds. Thepower supply module is enabled/disabled by the IPMC.

    60 / 112 3BK 20980 AAAA TQZZA Ed.07

  • 7/30/2019 BSC Disceription B9

    61/112

    4 ATCA Shelf

    4.5.3 Front Plate

    The following figure shows the front plate of the JBXTP board.

    Handle

    H1

    H2

    H3

    L1

    L2

    L3

    H4

    HandleX1

    X2

    X3

    JBXTP

    Figure 27: JBXTP Front Plate

    3BK 20980 AAAA TQZZA Ed.07 61 / 112

  • 7/30/2019 BSC Disceription B9

    62/112

    4 ATCA Shelf

    4.5.4 LEDs

    The following table describes the LEDs available on the JBXTP board frontplate.

    LED Description Color

    H1 Out of service (OOS)

    Indicates a failure or other an out of servicestate.

    ON: Board is out of service (OOS)

    OFF: Board is operational

    Red/Amber

    H2 Power Status

    ON: All supplies on the board are present

    OFF: At least one supply is failed

    Yellow

    H3 Master/Slave

    ON: Board is active (Master)

    OFF: Board is standby (Slave)

    Amber

    H4 Hot-swap

    ON: On board IPMC powers up or boardready to be extracted

    Blinking: Activation/Deactivation on going

    OFF: Board active or board not ready to beextracted

    Blue

    L1 Fault Status

    ON: Fault

    OFF: No fault

    Red

    L2 Ethernet Activity Status

    ON (BLINKIN