26
Bulletin 800R NEMA Style Push Buttons Hermetically Sealed For Division 2 NEMA Type 4/13 and 4/4X For Hazardous Locations 11-364 Bulletin 800R NEMA Style Hazardous Location Push Buttons Classes I and II Division 2 Only 30.5mm Mounting Hole NEMA Types 4/13 and 4/4X Stations and Operators TABLE OF CONTENTS Description Page Description Page Technical Data 11-365 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stations Complete Assembled, Metallic Enclosures 11-366 . . . . . . . . . . . . . . . Complete Assembled, Non-Metallic Enclosures 11-367 . . . . . . . . . . Push Buttons Momentary Contact, Non-Illuminated 11-368 . . . . . . . . . . . . . . . . . . . Momentary Contact, Flip Lever 11-370 . . . . . . . . . . . . . . . . . . . . . . . . Mechanically Interlocked Maintained 11-370 . . . . . . . . . . . . . . . . . . . . Momentary Contact, Illuminated 11-372 . . . . . . . . . . . . . . . . . . . . . . . . Push-Pull, Non-Illuminated 2 Position Push-Pull/Twist 11-374 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position Push-Pull 11-374 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Push-Pull, Illuminated 2 Position Push-Pull/Twist 11-376 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position Push-Pull 11-376 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selector Switches, Non-Illuminated 2 Position 11-378 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position 11-378 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Position 11-380 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pilot Lights Standard 11-382 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Push-To-Test 11-382 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dual Input 11-382 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Typical Pilot Light Wiring Diagrams 11-382 . . . . . . . . . . . . . . . . . . . . . Custom Built Stations 11-384 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enclosures Only 11-384 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modifications and Accessories Contact Blocks 11-385 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conversion Tables 11-386 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions 11-389 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-364

Bulletin 800R

NEMA StyleHazardous Location

Push Buttons

Classes I and IIDivision 2 Only

30.5mmMounting Hole

NEMA Types4/13 and 4/4X

Stations andOperators

TABLE OF CONTENTSDescription Page Description PageTechnical Data 11-365. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stations

Complete Assembled, Metallic Enclosures 11-366. . . . . . . . . . . . . . . Complete Assembled, Non-Metallic Enclosures 11-367. . . . . . . . . .

Push ButtonsMomentary Contact, Non-Illuminated 11-368. . . . . . . . . . . . . . . . . . . Momentary Contact, Flip Lever 11-370. . . . . . . . . . . . . . . . . . . . . . . . Mechanically Interlocked Maintained 11-370. . . . . . . . . . . . . . . . . . . . Momentary Contact, Illuminated 11-372. . . . . . . . . . . . . . . . . . . . . . . .

Push-Pull, Non-Illuminated2 Position Push-Pull/Twist 11-374. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position Push-Pull 11-374. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Push-Pull, Illuminated2 Position Push-Pull/Twist 11-376. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position Push-Pull 11-376. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selector Switches, Non-Illuminated2 Position 11-378. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position 11-378. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Position 11-380. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pilot LightsStandard 11-382. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Push-To-Test 11-382. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dual Input 11-382. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Typical Pilot Light W iring Diagrams 11-382. . . . . . . . . . . . . . . . . . . . . Custom Built Stations 11-384. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enclosures Only 11-384. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modifications and Accessories

Contact Blocks 11-385. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conversion Tables 11-386. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions 11-389. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

ELECTRICAL RATINGSContact RatingsRefer to the Contact Ratings tables to the right.Dielectric Strength2200 Volts for one minute1300 Volts for one minute (Logic Reed)Electrical Design Life Cycles1,000,000 at maximum rated load200,000 at maximum rated load (Logic Reed)

MECHANICAL RATINGSVibration10-2000 Hz 1.52mm displacement (peak-to-peak)Max./10G Max. (except Logic Reed)Shock1/2 cycle sine wave for 11 milliseconds � 25G (contact fragility)and no damage at 100GDegree of ProtectionNEMA Type 4/4X, 4/13; Watertight/Corrosion-ResistantIEC 529 IP 66/65Mechanical Design Life CyclesPush Buttons (Momentary, Non-illuminated): 10,000,000 min.

(Momentary, Illuminated): 250,000 min.(Push-Pull / Twist to Release): 250,000 min.

Selector Switches (Non-illuminated): 1,000,000 min.(Illuminated): 200,000 min.

All other devices: 200,000 min.Contact OperationLogic Reed & Sealed Switch Contact Blocks:

Single break magneticTypical Operating ForcesOperators without contact blocks:

Flush, Extended, Standard Mushroom,Jumbo Plastic Mushroom: 2 lbs. Max.Maintained Selector Switch: 3.6 in. lbs. maximum

Spring Return Selector Switches:3.6 in. lbs. to stop0.2 in. lbs. to return

Illuminated Push Buttons and Push-to-Test Pilot Lights:5 lbs. maximum

3 Position Push-Pull:8 lbs. maximum push to in position or pull to center position (15 lbs.maximum pull to out position)

Push-Pull and Push-Pull/Twist:9 lbs. maximum push or pull30 in. oz. maximum twist, 6 in. oz. minimum return

Contact Blocks:Logic Reed: 1 lb. maximumSealed Switch: 3 lbs. maximum at 0.205” plunger travel

ENVIRONMENTTemperature RangeOperating: +14°F to +131°F (-10°C to +55°C)Storage: -40°F to +185°F (-40°C to +85°C)Note: Operating temperatures at -10°C are based on theabsence of freezing moisture and liquids. Contact your localAllen-Bradley sales office for use in lower temperatureapplications.Humidity50% at +104°F (+40°C)

� Performance Data — See Page Important-2.

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-365

Technical Data �

Control StationsBulletin 800R Control Stations are designed for Division 2hazardous locations. They consist of Bulletin 800H (NEMAType 4/4X) or Bulletin 800T (NEMA Type 4/13) operators withsealed contact blocks. Bulletin 800R units are available asfactory assembled stations or as components for field assembly.

Hazardous LocationsSince the contacts are enclosed in a hermetically sealedchamber, the contact block is suitable for use in Class I and II,Division 2, Groups A, B, C, D, F and G hazardou s locationsand i s listed by Underwriters Laboratories for this class ofservice. Complete stations as shown on Page 11-366 can beused for Class I and II Division 2 applications. The individualcomponents on Pages 11-368 thru 11-383 are also suitable forClass I and II Division 2 locations providing they are suitablymounted by the customer in an enclosure as required for theapplication and by applicable codes and laws.Per National Electrical Code: Zone 2. In Class I, Zone 2locations, all wiring methods permitted for Class I, Division 2,Class I, Division 1 or Division 2, and Class I, Zone 0 or Zone 1locations, including requirements for sealing, shall be permitted.NOTE: Allen-Bradley logic reed contact blocks are alsolisted by Underwriters Laboratories for the Division 2hazardous locations listed above.

The complete stations and individual compo-nents listed herein ARE NOT SUITABLE FORUSE IN CLASS I AND II DIVISION 1 HAZ-ARDOUS LOCATIONS. For Class I and II Divi-sion 1 hazardous locations, order Bulletin 800HNEMA Type 7 & 9 stations and units.

! CAUTION:

Sealed Switch Contact RatingsMaximum continuous current Ith 5 Amperes. Bulletin 800T and800H units have control circuit ratings with sealed switchcontact blocks as follows:

Max.Opertnl.

UtilizationCategory

Rated OperationalCurrentsOpertnl .

Volts Ue IEC NEMA Volts Ue Make Break

AC 600 AC-15 B600120-600

0-1203600VA

30A360VA

3A

DC 300 DC-13 P30024-300

0-24138VA5.0A

Stackable Sealed Switch Contact RatingsMaximum continuous current Ith 3 Amperes. Bulletin 800Tand 800H units have control circuit ratings with sealedswitch contact blocks as follows:

Max.Opertnl.

UtilizationCategory

Rated OperationalCurrentsOpertnl .

Volts Ue IEC NEMA Volts Ue Make Break

AC 300 AC-15 C300120-300

0-1201800VA

15A180VA1.5A

DC 150 DC-13 Q15024-150

0-2469VA2.5A

Logic Reed Contact RatingsMaximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15AShould only be used with resistive loads

ApprovalsUL Listed: – File E10314 – Guide NOIVCSA Certified: LR11924IEC Compliance

Page 3: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-366 � Prices – Consult Sales Office or price list

Complete Assembled Stations, Metallic Enclosures NEMA Type 4

Dimensions – Page 11-389

Surface MountCatalog Number 800R-1TA

Booted Operator StationCatalog Number 800R-1HA4T

Bootless Operator StationCatalog Number 800R-1HA4TL

Contact B tton Type/ Legend

SteelEnclosures � Stainless Steel Enclosures �

Operator ContactSymbol

Button Type/Color

LegendMarking Surface Mount Booted

Operator StationBootless

Operator StationCatalog No. � Catalog No. � Catalog No. �

Flush/Green START 800R-1TB 800R-1HB4T 800R-1HB4TLOnePush

1 N.O. - Extended/Red STOP 800R-1TA 800R-1HA4T 800R-1HA4TLPush

Button

1 N.O. 1 N.C. Mushroom/Red EMRG. STOP 800R-1TKG — 800R-1HK4TLGButton

Flush/Black No Legend 800R-1TX 800R-1HX4T 800R-1HX4TL

Flush/Green START800R 2TA 800R 2HA4T 800R 2HA4TLTwo

Push1 N.O. -

Flush/GreenExtended/Red

STARTSTOP 800R-2TA 800R-2HA4T 800R-2HA4TL

PushButtons

1 N.O. 1 N.C.Each Flush/Black

No Legends 800R 2TX 800R 2HX4T 800R 2HX4TLButtons EachButton

Flush/BlackFlush/Black No Legends 800R-2TX 800R-2HX4T 800R-2HX4TL

Red120V AC Red No Legend

OneRed

120V AC RedFlush/Green

No LegendSTART 800R-2TAR 800R-2HAR4T 800R-2HAR4TLOne

Pilot LightFlush/Green

Extended/RedSTARTSTOP

800R 2TAR 800R 2HAR4T 800R 2HAR4TLPilot LightTwo Push 1 N.O. -

1 N C120V AC RedTwo Push

Buttons 1 N.C.Each120V AC RedFlush/Black No Legends 800R-2TXR 800R-2HXR4T 800R-2HXR4TLEach

ButtonFlush/BlackFlush/Black

No Legends 800R 2TXR 800R 2HXR4T 800R 2HXR4TL

3 PositionSelector 1 N.O. -

MaintainedHAND OFF

AUTO 800R-R3TA — 800R-R3HA4TLSelectorSwitch

1 N.O. 1 N.C. Maintained No Legend 800R-R3TX — 800R-R3HX4TL

One PushButton

Maintnd.

1 N.O. -1 N.C.

Push-Pull/TwistRed EMRG. STOP 800R-1TAM — 800R-1HAM4TL

Two PushButtons 1 N.O. -

Flush/GreenExtended/Red

STARTSTOP 800R-2TAM 800R-2HAM4T 800R-2HAM4TL

ButtonsMaintnd.

1 N.O. 1 N.C. Flush/Black

No Legends 800R 2TXM 800R 2HXM4T 800R 2HXM4TLMaintnd. Flush/BlackFlush/Black No Legends 800R-2TXM 800R-2HXM4T 800R-2HXM4TL

� NEMA Type 4/13.

� NEMA Type 4 only.

Page 4: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-367� Prices – Consult Sales Office or price list

Complete Assembled Stations, Non-Metallic Enclosures NEMA Type 4/4X/13

Dimensions – Page 11-389

Booted Operator StationCatalog Number 800R-1HA4R

Bootless Operator StationCatalog Number 800R-1HA4RL

Contact B tton Type/ LegendROSITE Glass Polyester Enclosures

Operator ContactSymbol

Button Type/Color

LegendMarking Booted Operator Station Bootless Operator Stationp Symbol Color Marking

Catalog Number � Catalog Number �

Flush/Green START 800R-1HB4R 800R-1HB4RLOnePush

1 N.O. - Extended/Red STOP 800R-1HA4R 800R-1HA4RLPush

Button

1 N.O. 1 N.C. Mushroom/Red EMERG. STOP — 800R-1HK4RLGButton

Flush/Black No Legend 800R-1HX4R 800R-1HX4RL

Flush/Green START800R 2HA4R 800R 2HA4RLTwo

Push1 N.O. -

Flush/GreenExtended/Red

STARTSTOP 800R-2HA4R 800R-2HA4RL

PushButtons

1 N.O. 1 N.C.Each Flush/Black

No Legends 800R 2HX4R 800R 2HX4RLButtons EachButton

Flush/BlackFlush/Black No Legends 800R-2HX4R 800R-2HX4RL

Red120V AC Red No Legend

OneRed

120V AC RedFlush/Green

No LegendSTART 800R-2HAR4R 800R-2HAR4RLOne

Pilot LightFlush/Green

Extended/RedSTARTSTOP

800R 2HAR4R 800R 2HAR4RLPilot LightTwo Push 1 N.O. -

1 N C120V AC RedTwo Push

Buttons 1 N.C.Each120V AC RedFlush/Black No Legends 800R-2HXR4R 800R-2HXR4RLEach

ButtonFlush/BlackFlush/Black

No Legends 800R 2HXR4R 800R 2HXR4RL

3 PositionSelector 1 N.O. -

MaintainedHAND OFF

AUTO — 800R-R3HA4RLSelectorSwitch

1 N.O. 1 N.C. Maintained No Legend — 800R-R3HX4RL

One PushButton

Maintained

1 N.O. -1 N.C.

Push-Pull/TwistRed EMERG. STOP — 800R-1HAM4RL

Flush/Green START800R 2HAM4R 800R 2HAM4RLTwo Push

Buttons 1 N.O. -

Flush/GreenExtended/Red

STARTSTOP 800R-2HAM4R 800R-2HAM4RL

ButtonsMaintained

1 N.O. -1 N.C. Flush/Black

No Legends 800R 2HXM4R 800R 2HXM4RLMaintained C Flush/BlackFlush/Black No Legends 800R-2HXM4R 800R-2HXM4RL

Page 5: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-368 � Prices – Consult Sales Office or price list

Momentary Contact Push Button Units, Non-IlluminatedLegend Plates – Pages 11-46,11-91Accessories – Page 11-385Dimensions – Page 11-389

Booted UnitCatalog Number 800H-R1D2P

Bootless Flush Head UnitCatalog Number 800H-AR1AP

Bootless Extended Head UnitCatalog Number 800H-BR6AP

Contact Type ButtonColor

Booted � BootlessFlush Head

BootlessExtended HeadContact Type Color

Catalog Number � Catalog Number � Catalog Number �

1 N.C.GreenBlackRed

800H-R1D2P800H-R2D2P800H-R6D2P

800H-AR1D2P800H-AR2D2P

800H-BR1D2P800H-BR2D2P800H-BR6D2P

1 N.O.GreenBlackRed

800H-R1D1P800H-R2D1P800H-R6D1P

800H-AR1D1P800H-AR2D1P

800H-BR1D1P800H-BR2D1P800H-BR6D1P

1 N.O. - 1 N.C.GreenBlackRed

800H-R1AP800H-R2AP800H-R6AP

800H-AR1AP800H-AR2AP

800H-BR1AP800H-BR2AP800H-BR6AP

2 N.O. - 2 N.C.GreenBlackRed

800H-R1BP800H-R2BP800H-R6BP

800H-AR1BP800H-AR2BP

800H-BR1BP800H-BR2BP800H-BR6BP

Note: For NEMA 4/13 metal products see page 11-369.

Bootless Guarded HeadCatalog Number 800H-GR1AP

Bootless Mushroom HeadCatalog Number 800H-DR6AP

Jumbo Mushroom HeadCatalog Number 800H-DR6JAP

Contact Type ButtonColor

BootlessGuarded Head

BootlessMushroom Head

JumboMushroom HeadContact Type Color

Catalog Number � Catalog Number � Catalog Number �

1 N.C.GreenBlackRed

800H-GR1D2P800H-GR2D2P

800H-DR1D2P800H-DR2D2P800H-DR6D2P

800H-DR1JD2P800H-DR2JD2P800H-DR6JD2P

1 N.O.GreenBlackRed

800H-GR1D1P800H-GR2D1P

800H-DR1D1P800H-DR2D1P800H-DR6D1P

800H-DR1JD1P800H-DR2JD1P800H-DR6JD1P

1 N.O. - 1 N.C.GreenBlackRed

800H-GR1AP800H-GR2AP

800H-DR1AP800H-DR2AP800H-DR6AP

800H-DR1JAP800H-DR2JAP800H-DR6JAP

2 N.O. - 2 N.C.GreenBlackRed

800H-GR1BP800H-GR2BP

800H-DR1BP800H-DR2BP800H-DR6BP

800H-DR1JBP800H-DR2JBP800H-DR6JBP

Note: For NEMA 4/13 metal products see page 11-369.� Green and black operators are flush; red units are extended head.

Page 6: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-369� Prices – Consult Sales Office or price list

Momentary Contact Push Button Units, Non-Illuminated

800 T – A 1 APa b c d e

aNEMA Type

Code Description �

T NEMA Type 4/13

H NEMA Type 4/4X

b

Operator TypeNEMA Type 4/13

Code Description �

A Flush Head �

B Extended Head

D Mushroom Head

DX Mushroom Head less Color Cap

NEMA Type 4/4X

Code Description �

AR Flush Head �

BR Extended Head

DR Mushroom Head

DRX Mushroom Head less Color Cap

GR Bootless Guarded Head

R Booted Head �

cColor Cap

Code Color �

Blank Used only when orderingOperator Type “DX”

1 Green

2 Black

3 Orange �

4 Gray �

5 White �

6 Red

7 Blue

9 Yellow

dSpecial Mushroom Head

Code Description �

Blank No Special Head

J Jumbo Mushroom Head — Plastic

L Jumbo Mushroom Head — Metal

Note: Special Mushroom Head options only apply to Mush-room Head operator Type Code “D” or “DR” . Special Mush-room Head option “L” only valid with NEMA 4/13 operatortype “D” .

eContact Blocks

Sealed Switch

Code Description �

Blank No Contacts

D1P 1 N.O.

D2P 1 N.C.

A2P 2 N.O.

A4P 2 N.C.

AP 1 N.O. - 1 N.C.

BP 2 N.O. - 2 N.C

Stackable Sealed Switch

Code Description �

D1Y 1 N.O.

D2Y 1 N.C.

A2Y 2 N.O.

A4Y 2 N.C.

AY 1 N.O. - 1 N.C.

BY 2 N.O. - 2 N.C

HY 3 N.O. - 3 N.C.

CY 4 N.O. - 4 N.C

Logic Reed

Code Description �

Blank No Contacts

D1R 1 N.O.

D2R 1 N.C.

A2R�� 2 N.O.

A4R 2 N.C.

AR 1 N.O. - 1 N.C.

BR 2 N.O. - 2 N.C.

HR 3 N.O. - 3 N.C.

CR 4 N.O. - 4 N.C.

� Red flush head operators are not recommended for Emergency Stop applications.� Green and black operators are flush underneath boots; red operators are extended.� Not available for booted operators.� 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.

Page 7: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-370 � Prices – Consult Sales Office or price list

Momentary Contact Flip Lever Operators — NEMA Type 4Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Flip Lever OperatorCatalog Number 800H-WK42AP

Flip Lever OperatorCatalog Number 800H-WK61AP

Contac t Type B tto n Color Hot Stamped Flip LeverContact Type Button Color Hot Stamped

Legend Marking Catalog Number �

Gray START 800H-WK42AP

1 N O 1 N CGray No Legend 800H-WK4AP

1 N.O. - 1 N.C.Red STOP 800H-WK61AP

Red No Legend 800H-WK6AP

Gray START 800H-WK42BP

2 N O - 2 N CGray No Legend 800H-WK4BP

2 N.O. - 2 N.C.Red STOP 800H-WK61BP

Red No Legend 800H-WK6BP

Mechanically Interlocked Maintained Push Button UnitsLegend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Bootless OperatorCatalog Number 800H-CRA22AP

Booted OperatorCatalog Number 800H-FRB16AP

Contac t ArrangementBooted Bootless

Contact ArrangementButton Type Color Button Type Color Button Type Color

Type Configuration/Position

Upper: FlushLower: Extended

GreenRed

Upper: FlushLower: Extended

GreenRed

Upper: FlushLower: Flush

BlackBlackType Position

Catalog Number � Catalog Number � Catalog Number �

1 N.O. -1 N.C.

800H-FRB16AP 800H-CRB16AP 800H-CRA22AP

2 N.O. -2 N.C. 800H-FRB16FP 800H-CRB16FP 800H-CRA22FP

Note: For NEMA 4/13 metal products see page 11-371.

Page 8: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-371� Prices – Consult Sales Office or price list

Momentary Contact Flip Lever Operators — NEMA Type 4

800H– WK 4 2 BPa b c d

aOperator Type

Code Description �

WK Flip Lever

bColor

Code Description �

4 Gray

6 Red �

cLegend Plate Marking

Code Marking �

Blank No Legend �

1 Stop

2 Start

dContact Blocks

Sealed Switch

Code Description �

Blank No Contacts

D1P 1 N.O.

D2P 1 N.C.

A2P 2 N.O.

A4P 2 N.C.

AP 1 N.O. - 1 N.C.

BP 2 N.O. - 2 N.C

Stackable Sealed Switch

Code Description �

D1Y 1 N.O.

D2Y 1 N.C.

A2Y 2 N.O.

A4Y 2 N.C.

d (cont’d)Contact Blocks

Stackable Sealed Switch

Code Description �

AY 1 N.O. - 1 N.C.

BY 2 N.O. - 2 N.C.

HY 3 N.O. - 3 N.C.

CY 4 N.O. - 4 N.C.

Logic Reed

Code Description �

Blank No Contacts

D1R 1 N.O.

D2R 1 N.C.

A2R 2 N.O. �

A4R 2 N.C.

AR 1 N.O. - 1 N.C.

BR 2 N.O. - 2 N.C.

HR 3 N.O. - 3 N.C.

CR 4 N.O. - 4 N.C.

Mechanically Interlocked Maintained Push Button Units

800 T – F A 2 6 APa b c d e f g

aNEMA Type

Code Description �

T NEMA Type 4/13

H NEMA Type 4/4X

bOperator TypeNEMA Type 4/13

Code Description �

F Vertical Mounting

G Horizontal Mounting

NEMA Type 4/4X

Code Description �

CR Bootless Operator

FR Booted Operator

cButton Position and Function

Upper or Left/Lower or Right

Code Description �

Blank Maintained/Maintained

Y Momentary/Maintained

Z Maintained/Momentary

dNEMA Type

Head Type 4/13 Upper or Left/Lower or Right

Code Description �

A Flush/Flush

B Flush/Extended

C Flush/Mushroom

D Mushroom/Mushroom

E Extended/Flush

F Flush/Cylinder Lock

G Mushroom/Flush

H Mushroom/Extended

J Extended/Extended

Head Type 4/4X Upper or Left/Lower or Right

Code Description �

A Flush/Flush

B Flush/Extended

E Extended/Flush

J Extended/Extended

e,fButton Color

Upper or Left/Lower or Right

Code Color �

1 Green

2 Black

3 Orange �

4 Gray �

e,fButton Color

Upper or Left/Lower or Right

Code Color �

5 White �

6 Red �

7 Blue

9 Yellow

gSealed Contact Blocks

Sealed Switch

Code Description �

D1P 1 N.O.

D2P 1 N.C.

AP 1 N.O. - 1 N.C.

FP 2 N.O. - 2 N.C.

Stackable Sealed Switch

Code Description �

D1Y 1 N.O.

D2Y 1 N.C.

AY 1 N.O. - 1 N.C.

FY 2 N.O. - 2 N.C.

Logic Reed

Code Description �

D1R 1 N.O.

D2R 1 N.C.

AR 1 N.O. - 1 N.C.

FR 2 N.O. - 2 N.C.

� Locking provision is supplied as standard on red units. � Legend plate not included but may be ordered as a separate item.� 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.� Not available with booted operators. � Red flush head operators are not recommended for Emergency Stop applications.

Page 9: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-372 � Prices – Consult Sales Office or price list

Momentary Contact Push Button Units, Illuminated

Extended Head Without GuardCatalog Number 800H-PRB16RAP

Extended Head With GuardCatalog Number 800H-PRA16RAP

Illuminated Mushroom HeadCatalog Number 800H-PRM16RAP

Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Lamp Type Volts ColorExtended Head Without Guard

Extended HeadWith Guard Mushroom Head

Lamp Type Volts ColorCatalog Number � Catalog Number � Catalog Number �

Full120 AC

RedGreenAmber

800H-QRB10RAP800H-QRB10GAP800H-QRB10AAP

800H-QRA10RAP800H-QRA10GAP800H-QRA10AAP

800H-QRM10RAP800H-QRM10GAP800H-QRM10AAP

Incan-descent

FullVoltage

24 AC/DCRed

GreenAmber

800H-QRB24RAP800H-QRB24GAP800H-QRB24AAP

800H-QRA24RAP800H-QRA24GAP800H-QRA24AAP

800H-QRM24RAP800H-QRM24GAP800H-QRM24AAP

Trans-former 120 AC

RedGreenAmber

800H-PRB16RAP800H-PRB16GAP800H-PRB16AAP

800H-PRA16RAP800H-PRA16GAP800H-PRA16AAP

800H-PRM16RAP800H-PRM16GAP800H-PRM16AAP

Full120 AC

RedGreenAmber

800H-QRBL10RAP800H-QRBL10GAP800H-QRBL10AAP

800H-QRAL10RAP800H-QRAL10GAP800H-QRAL10AAP

800H-QRML10RAP800H-QRML10GAP800H-QRML10AAP

LED4 Chip

FullVoltage

24 AC/DCRed

GreenAmber

800H-QRBL24RAP800H-QRBL24GAP800H-QRBL24AAP

800H-QRAL24RAP800H-QRAL24GAP800H-QRAL24AAP

800H-QRML24RAP800H-QRML24GAP800H-QRML24AAP

Trans-former 120 AC

RedGreenAmber

800H-PRBL16RAP800H-PRBL16GAP800H-PRBL16AAP

800H-PRAL16RAP800H-PRAL16GAP800H-PRAL16AAP

800H-PRML16RAP800H-PRML16GAP800H-PRML16AAP

LEDFull

120 ACRed

GreenAmber

800H-QRBH10RAP800H-QRBH10GAP800H-QRBH10AAP

800H-QRAH10RAP800H-QRAH10GAP800H-QRAH10AAP

800H-QRMH10RAP800H-QRMH10GAP800H-QRMH10AAP

LED28 Chip

HighVisibility

FullVoltage

24 AC/DCRed

GreenAmber

800H-QRBH24RAP800H-QRBH24GAP800H-QRBH24AAP

800H-QRAH24RAP800H-QRAH24GAP800H-QRAH24AAP

800H-QRMH24RAP800H-QRMH24GAP800H-QRMH24AAP

Visibility

Trans-former 120 AC

RedGreenAmber

800H-PRBH16RAP800H-PRBH16GAP800H-PRBH16AAP

800H-PRAH16RAP800H-PRAH16GAP800H-PRAH16AAP

800H-PRMH16RAP800H-PRMH16GAP800H-PRMH16AAP

Note: For NEMA 4/13 metal 30 mm operators see page 11-373.

Page 10: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-373� Prices – Consult Sales Office or price list

Momentary Contact Push Button Units, llluminated

800 T – P B L 16 R APa b c d e f g

aOperator Type

Code Description �

T NEMA Type 4/13

H NEMA Type 4/4X

bPower Module T ype

NEMA Type 4/13

Code Description �

P Transformer(or Dual Input)

Q Full Voltage(or Resistor)

R Neon �

NEMA Type 4/4X

Code Description �

PR Transformer(or Dual Input)

QR Full Voltage(or Resistor)

RR Neon �

cHead Type

Code Description �

A Extended Headwith Guard �

B Extended Headwithout Guard

M Mushroom

MJ Jumbo Mushroom

dIllumination Options

Transformer

Code Description �

Blank Standard Pilot Light

F Flashing Lamp �

H LED Cluster ��

L LED ��

Full Voltage

Code Description �

Blank Standard Pilot Light

F Flashing Lamp

H LED Cluster ��

L LED ��

Resistor

Code Description �

Blank No Options

Neon

Code Description �

Blank No Options

Dual Input

Code Description �

D Diode Type

T Transformer-RelayType

TH Transformer-RelayType w/LED Cluster

TL Transformer-RelayType w/LED

eVoltage

Transformer

Code Description �

36 48V AC 50/60 Hz

16 120V AC 50/60 Hz

26 240V AC 50/60 Hz

76 277V AC 50/60 Hz

46 480V AC 50/60 Hz

56 600V AC 50/60 Hz

Full Voltage

Code Description �

06 6V AC/DC

12 12V AC/DC

24 24V AC/DC

10 120V AC/DC

20 240V AC/DC

Resistor

Code Description �

11 120V AC/DCResistor

Neon

Code Description �

10 120V AC/DC

20 240V AC/DC

Dual Input

Code Description �

16 120V AC 50/60 Hz

24 24V AC/DC50/60 Hz �

fLens Color

Code Color �

X No Lens

A Amber

B Blue

C Clear

G Green

R Red

W White

gSealed Contact Blocks

Sealed Switch

Code Description �

D1P 1 N.O.

D2P 1 N.C.

AP 1 N.O. - 1 N.C.

X No Contacts

Stackable Sealed Switch

Code Description �

D1Y 1 N.O.

D2Y 1 N.C.

A2Y 2 N.O.

A4Y 2 N.C.

AY 1 N.O. - 1 N.C.

BY 2 N.O. - 2 N.C.

Logic Reed

Code Description �

D1R 1 N.O.

D2R 1 N.C.

A2R 2 N.O. �

A4R 2 N.C.

AR 1 N.O. - 1 N.C.

BR 2 N.O. - 2 N.C.

X No Contacts

� Neon is only available in amber or clear.� Red flush head operators are not recommended for Emergency Stop applications.� Flashing lamps are only available in 6V Full Voltage units and all Transformer units.� LEDs are only available in red, green and amber; lens color must match LED color.� Use only with 6V AC, 24V AC/DC and 120V AC Full Voltage units, and all Transformer units.� Dual Input diode only.� 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.

Page 11: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-374 � Prices – Consult Sales Office or price list

2 Position Push-Pull/ Twist Release Units, Non-Illuminated

Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389Note: A jumbo or large legend plate isrecommended, if space allows.

2 Position Push-Pull/TwistCatalog Number 800H-FRXT6D2P

Note: X=Closed/O=Open

Operator Position

Contact TypeMaintained Maintained

ButtonColor

Push-Pull/Twist Release

Out In Catalog Number �

N.C. X O Red 800H-FRXT6D2P

N.O. -N.C.

OX

XO Red 800H-FRXT6AP

N.C. -N.C.

XX

OO Red 800H-FRXT6A4P

Note: For NEMA 4/13 metal 30 mm operators see page 11-375.

3 Position Push-Pull Units, Non-Illuminated

Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389Note: A jumbo or large legend plate isrecommended, if space allows.

3 Position Push-PullCatalog Number 800H-FRXM6AP

Note: X=Closed/O=Open

Operator Position

Contact TypeMomentary Maintained Maintained

ButtonColor

Push-Pull

Out Center In Catalog Number �

N.O. -N.C.

OX

OO

XO Red 800H-FRXM6AP

Operator Position

Contact TypeMomentary Maintained Momentary

ButtonColor

Push-Pull

Out Center In Catalog Number �

N.O. -N.C.

OX

OO

XO Red 800H-FRXN6AP

Note: For NEMA 4/13 metal 30 mm operators see page 11-375.

Page 12: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-375� Prices – Consult Sales Office or price list

2 Position Push-Pull/Twist Release Units, Non-Illuminated

800 T – FX 1 APa b c d e

aOperator Type

Code Description �

T NEMA Type 4/13

H NEMA Type 4/4X

bOperator TypeNEMA Type 4/13

Code Description �

FX Push-Pull or Push-Pull Twist

NEMA Type 4/4X

Code Description �

FRX Push-Pull Twist Unit �

cHead Type

Code Description �

Blank Mushroom Head ��

J Jumbo Mushroom Head �

T Twist to Release

JT Jumbo Head w/Twist to Release

dColor Cap

Code Color �

Blank No Cap �

1 Green

2 Black

3 Orange

4 Gray

5 White

6 Red

7 Blue

9 Yellow

eContact Block(s)

Sealed SwitchOperator Position

Code

Out In

Description �

Blank — — No Contacts

D1P O X 1 N.O.

D2P X O 1 N.C.

AP OX

XO

1 N.O.1 N.C.

A4P XX

OO

2 N.C.

e (cont’d)Contact Block(s)

Stackable Sealed SwitchOperator Position

Code

Out In

Description �

D1Y O X 1 N.O.

D2Y X O 1 N.C.

A2Y OO

XX

2 N.O.

A4Y XX

OO

2 N.C.

AY OX

XO

1 N.O. - 1 N.C.

Logic ReedOperator Position

Code

Out In

Description �

D1R O X 1 N.O.

D2R X O 1 N.C.

AR OX

XO

1 N.O. - 1 N.C.

A2R OO

XX

2 N.O. �

A4R XX

OO

2 N.C.

Note: X=Closed/O=Open

3 Position Push-Pull Units, Non-Illuminated

800 T – FX M 1 APa b c d e f

aOperator Type

Code Description �

T NEMA Type 4/13

H NEMA Type 4/4X

bOperator TypeNEMA Type 4/13

Code Description �

FX Push-Pull Unit

NEMA Type 4/4X

Code Description �

FRX Push-Pull Unit

cHead Type

Code Description �

Blank Mushroom Head

J Jumbo Mushroom Head

dOperator Function

Operator Position

Code

Out Ctr. In

M Momentary Maintained Maintained

N Momentary Maintained Momentary

eColor Cap

Code Color �

Blank No Cap �

1 Green

2 Black

3 Orange

4 Gray

5 White

6 Red

7 Blue

9 Yellow

fContact Block(s)

Operator Position

Code

Out Ctr. In

Description �

Sealed Switch

AP OX

OO

XO

1 N.O. - 1 N.C.

BP

OXOX

OOOO

XOXO

2 N.O. - 2 N.C.

Stackable Sealed Switch

AY OX

OO

XO

1 N.O. - 1 N.C.

BY

OXOX

OOOO

XOXO

2 N.O. - 2 N.C.

Logic Reed

AR OX

OO

XO

1 N.O. - 1 N.C.

BR

OXOX

OOOO

XOXO

2 N.O. - 2 N.C.

Note: X=Closed/O=Open

� Must select Head Type “T” or “JT” to complete this catalog number. ��Not valid with “FRX” Operator Type.� Not valid with Head Type “T” or “JT”. � 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.

Page 13: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-376 � Prices – Consult Sales Office or price list

2 Position Push-Pull/ Twist Release Units, Illuminated

Note: X=Closed/O=Open

Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Illuminated 2 Position Push-Pull/TwistCatalog Number 800H-FRXTP16RAP

Operator Position

Lamp Type Volts ColorMaintained Maintained

Push-Pull/ Twist Release

Contacts Out In Catalog Number �

Full 120 AC Red N.O. - O X 800H-FRXTQ10RAP

Incan-

FullVoltage 24 AC/DC Red

N.O. N.C.

OX

XO 800H-FRXTQ24RAPIncan

descent Trans- 120 AC Red N.O. - O X 800H-FRXTP16RAPTransformer 240 AC Red

N.O. N.C.

OX

XO 800H-FRXTP26RAP

Full 120 AC Red N.O. - O X 800H-FRXTQH10RAP

LED

FullVoltage 24 AC/DC Red

N.O. N.C.

OX

XO 800H-FRXTQH24RAP

LEDTrans- 120 AC Red N.O. - O X 800H-FRXTPL16RAPTransformer 240 AC Red

N.O. N.C.

OX

XO 800H-FRXTPL26RAP

Note: For NEMA Type 4/13 metal 30 mm operators see page 11-377.

3 Position Push-Pull Units, Illuminated

Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Illuminated 3 Position Push-PullCatalog Number 800H-FRXMP16RAP

Operator Position Operator Position

Momentary MaintainedMaintained Momentary MomentaryMaintained

Contacts Out Center In Contacts Out Center In

Note: X=Closed/O=OpenN.C. -N.O.

XO

OO

OX

N.C. -N.O.

XO

OO

OX

Lamp Type Volts ColorPush-Pull Push-Pull

Lamp Type Volts ColorCatalog Number � Catalog Number �

IFull 120 AC Red 800H-FRXMQ10RAP 800H-FRXNQ10RAP

Incan-descent

FullVoltage 24 AC/DC Red 800H-FRXMQ24RAP 800H-FRXNQ24RAP

descentTrnsfmr. 120 AC Red 800H-FRXMP16RAP 800H-FRXNP16RAP

Full 120 AC Red 800H-FRXMQH10RAP 800H-FRXNQH10RAP

LEDFull

Voltage 24 AC/DC Red 800H-FRXMQH24RAP 800H-FRXNQH24RAPLED

Trnsfmr. 120 AC Red 800H-FRXMPL16RAP 800H-FRXNPL16RAP

Note: For NEMA Type 4/13 metal 30 mm operators see page 11-377.

Page 14: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-377� Prices – Consult Sales Office or price list

2 Position Push-Pull/Twist Release and 3 Position Push-Pull Units, Illuminated

800 T – FX T PL 16 R APa b c d e f g h

aNEMA Type

Code Description �

T NEMA Type 4/13

H NEMA Type 4/4X

bOperator TypeNEMA Type 4/13

Code Description �

FX Push-Pull/Push-PullTwist

NEMA Type 4/4X

Code Description �

FRX Push-Pull/Push-PullTwist

cHead Type

Code Description �

Blank Mushroom Head

J Jumbo MushroomHead �

dOperator Function

2-Position

Code Description �

Blank Push-Pull��

T Push-Pull/Twist �

3 Position

Code Operator Position

Code

Out Ctr. In

M � � �

N � � �

� Momentary �Maintained

eIllumination Options

Transformer

Code Description �

P StandardIncandescent

PF Flashing Lamp��

PH LED Cluster ��

PL LED ��

Full Voltage

Code Description �

Q StandardIncandescent

QF Flashing Lamp��

QH LED Cluster ��

QL LED ��

Resistor

Code Description �

Q Incandescent Lamp��

Neon

Code Description �

R Neon Lamp

Dual Input

Code Description �

D Dual Input Diode

DT Dual Input-Transformer Relay

fVoltage

Transformer

Code Description �

36 48V AC 50/60 Hz

16 120V AC 50/60 Hz

26 240V AC 50/60 Hz

76 277V AC 50/60 Hz

46 480V AC 50/60 Hz

56 600V AC 50/60 Hz

Full Voltage

Code Description �

06 6V AC/DC

12 12V AC/DC

24 24V AC/DC

10 120V AC/DC

20 240V AC/DC

Resistor

Code Description �

11 120V AC/DCResistor

Neon

Code Description �

10 120V AC/DC

20 240V AC/DC

Dual Input

Code Description �

16 120V AC 50/60 Hz

24 24V AC/DC50/60 Hz�

gColor Cap

Code Color �

X No Cap

A Amber

B Blue

C Clear

G Green

R Red

W White

hContact Blocks

Sealed Switch

Code Description �

D1P 1 N.O.

D2P 1 N.C.

AP 1 N.O. - 1 N.C.

Note: See Table 1 for Target description.

Stackable Sealed Switch

Code Description �

D1Y 1 N.O.

D2Y 1 N.C.

A2Y 2 N.O.

A4Y 2 N.C.

AY 1 N.O. - 1 N.C.

BY 2 N.O. - 2 N.C.

Logic Reed

Code Description �

D1R 1 N.O.

D2R 1 N.C.

A2R 2 N.O.

A4R 2 N.C.

AR 1 N.O. - 1 N.C.

BR 2 N.O. - 2 N.C.

Table 1. Target Selection2 Position 3 Position

h Code

Out In

ContactDescription

Out Ctr. In

h Code

D1P or D1R O X N.O. — — — —

D2P or D2R X O N.C. — — — —

AR or AP OX

XO

N.O.N.C.

OX

OO

XO

AR or AP

BR

OXOX

XOXO

N.O.N.C.N.O.N.C.

OXOX

OOOO

XOXO

BR

Note : X=Closed/O=Open.

� Not valid with Color Cap option “X” (No Cap). � Only valid for 3 position devices and NEMA Type 4/13 2 position units.� Not valid for 3 position devices. � Flashing lamps are only available in 6V Full Voltage units and all Transformer units.� LEDs are only available in red, green and amber; Color Cap must match LED color.� Use only with 6V AC, 24V AC/DC and 120V AC Full Voltage units, and all Transformer Units.� 120V Power Module drops voltage 10% to extend lamp life. Neon is only available in amber or clear. Dual input diode only.

Page 15: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-378 � Prices – Consult Sales Office or price list

2 Position Selector Switch Units, Non-IlluminatedLegend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Note: X=Closed/O=Open

Standard Knob OperatorCatalog Number 800H-HR2AP

Contac t TypeContact Location Operator

PositionOperator

TypeStandard Knob

Contact TypeSide Actuator

Color Contact

TypeM=MaintainedS=Spring Return Catalog Number �

M M 800H-HR2D1P

1 N.O. 1 White A O X S�M � 800H-HR4D1P1 N.O. 1 White A O X

M�S 800H-HR5D1P

M M 800H-HR2D2P

1 N.C. 1 White B X O S�M � 800H-HR4D2P1 N.C. 1 White B X O

M�S 800H-HR5D2P

1 N O 1 Whit A O XM M 800H-HR2AP

1 N.O. -1 N C

11

WhiteWhite

AB

OX

XO

S�M � 800H-HR4AP1 N.C. 1 White B X O

M�S 800H-HR5AP

O1 White A O X M M 800H-HR2BP

2 N.O. -2 N.C.

112

WhiteWhiteBlack

ABA

OXO

XOX

S�M � 800H-HR4BP2 N.C. 22

BlackBlack

AB

OX

XO M�S 800H-HR5BP

� Target tables are reversed from those shown.Note: For NEMA Type 4/13 metal 30 mm operators see page 11-379.

3 Position Selector Switch Units, Non-Illuminated

Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Note: X=Closed/O=Open

Standard Knob OperatorCatalog Number 800H-JR2AP

Contac t TypeContact Location Operator

PositionOperator

TypeStandard Knob

Contact TypeSide Actuator

Color Contact

TypeM=MaintainedS=Spring Return Catalog Number �

M M M 800H-JR2AP

1 N.O. - 1 White A X O O S�M M 800H-JR4AP1 N.O. 1 N.C.

11

WhiteWhite

AB

XO

OO

OX M M�S 800H-JR5AP

S�M�S 800H-JR91AP

1 White A X O OM M M 800H-JR2BP

2 N.O. -11

WhiteWhite

AB

XO

OO

OX S�M M 800H-JR4BP2 N.O.

2 N.C.122

WhiteBlackBlack

BAB

OXO

OOO

XOX

M M�S 800H-JR5BP2 Black B O O X

S�M�S 800H-JR91BP

Note: For NEMA Type 4/13 metal 30 mm operators see page 11-379.

Page 16: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

(2 Position)

(3 Position)

Sealed Switch

Logic Reed

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-379� Prices – Consult Sales Office or price list

2 and 3 Position Selector Switch Units, Non-Illuminated

800 H–HR 2 D1Pa b c d e

800 T–J 5 KC1 HRa b c d1 e

aOperator Type

Code Description �

H-HR NEMA Type 4/4X 2 Position

H-JR NEMA Type 4/4X 3 Position

T-H � NEMA Type 4/13 2 Pos.

T-J � NEMA Type 4/13 3 Pos.

bKnob Insert Colors

Code Color �

Blank White knob insert orCylinder Lock Operator

A Red

B Green

C Blue

E Yellow

F Orange

X Packet of ColoredInserts �

cStandar d Knob Operators

Code Operator Function �

2 Maintained

4 Spring Return from Left

5 Spring Return from Right

91 � Spring Return from Both

dCam Option (2 Pos.)

Code Description �

Blank Std. Cam

KE8 KE8 Cam

Note: Associated cam targets shown inTable 1.

d1Cam Option (3 Pos.)

Code Description �

Blank KB7 Cam (Std.)

KA1 KA1 Cam

KA7 KA7 Cam

KC1 KC1 Cam

KC7 KC7 Cam

KD7 KD7 Cam

KE7 KE7 Cam

KQ1 KQ1 Cam

KQ7 KQ7 Cam

KR1 KR1 Cam

KR7 KR7 Cam

KT1 KT1 Cam

KT7 KT7 Cam

KU7 KU7 Cam

Note: Cam targets shown in Table 2.

eContact Blocks

Sealed SwitchCode Description �

Blank No contacts

D1P � 1 N.O.

D2P � 1 N.C.

AP1 N.O. - 1 N.C.

1-800T-XAP mountedon white side

BP

2 N.O. - 2 N.C.2-800T-XAP’s —1 on white side/1 on black side

Stackabl e Sealed Switch

Code Description �

D1Y � 1 N.O.

D2Y � 1 N.C.

AY1 N.O. - 1 N.C.

1-800T-XAY mountedon white side

BY

2 N.O. - 2 N.C.2-800T-XAY’s —1 on white side/1 on black side

HY

3 N.O. - 3 N.C.3-800T-XAY’s —2 on white side/1 on black side

CY

4 N.O. - 4 N.C.4-800T-XAY’s —2 on white side/2 on black side

e (cont’d)Contact Blocks

Logi c Reed

Code Description �

Blank No contacts

D1R � 1 N.O.

D2R � 1 N.C.

AR1 N.O. - 1 N.C.

1-800T-XAR mountedon white side

BR

2 N.O. - 2 N.C.2-800T-XAR’s —1 on white side/1 on black side

HR

3 N.O. - 3 N.C.3-800T-XAR’s —2 on white side/1 on black side

CR

4 N.O. - 4 N.C.4-800T-XAR’s —2 on white side/2 on black side

Note: Associated targets are shown inTable 1 for 2 position devices and Table 2for 3 position devices.

Table 1. 2 Position Cam and Contact Block Functionality Table Note: X=Closed/O=Open

C Cam Codes

Contact BlockSuffix Code

ContactBlock Side

Ckt

Std. Cam Maintained andSpring Returned from Right

Std. Cam Spring Returnedfrom Left KE8

Block Sides

D1P/D1R/D1Y White A O X X O X O

D2P/D2R/D2Y White B X O O X O X

AP/White

A O X X O X O

BP/BR/

AP/AR/AY White

B X O O X O X

HR/HY

BR/BY

BlackA O X X O O X

CR/HY

BYBlack

B X O O X X OCR/CY

WhiteA O X X O X O

WhiteB X O O X O X

BlackA O X X O O X

BlackB X O O X X O

Table 2. 3 Position Cam and Contact Block Functionality Table Note: X=Closed/O=Open

Con- C Cam CodesContac t Block

Suffix Code

Con-tact

BlockSid

Ckt

KB7(Std.) KA1 KA7 KC1 KC7 KD7 KE7 KQ1 KQ7 KR1 KR7 KT1 KT7 KU7

BlockSide s

AP / WhiteA X O O X O O O O X O O X X O O O O X X O O X O X X O X X O X X O X O O X X O O X O O

BP/BR

AP /AR/AY

WhiteB O O X O X O O X O O X O O X O O X O O X X O X O O X O O X O O X O X O O O O X O X O

HR/HY

BR/BY

BlackA X O O X O O O O X O O X X O O X O O O O X O O X X O O O O X X O O O O X X O O O O X

CR/

HR/HY

/BYBlack

B O O X O X O O X O X O O O O X O X O X X O O X O O X O X X O O X X X X O O X X X X OCR/CY

WhiteA X O O X O O O O X O O X X O O O O X X O O X O X X O X X O X X O X O O X X O O X O O

WhiteB O O X O X O O X O O X O O X O O X O O X X O X O O X O O X O O X O X O O O O X O X O

BlackA X O O X O O O O X O O X X O O X O O O O X O O X X O O O O X X O O O O X X O O O O X

BlackB O O X O X O O X O X O O O O X O X O X X O O X O O X O X X O O X X X X O O X X X X O

� Refer to Page 11-21 for additional knob and cylinder lock selections. � Refer to Page 11-23 for additional knob and cylinder lock selections.� Packet of colored inserts, one of each color except orange.�Option “91” only available on 3 position devices. �Available only on 2 position devices.

Page 17: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-380 � Prices – Consult Sales Office or price list

4 Position Selector Switch Units, Non-Illuminated ( Type 4/4X)Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Note: X=Closed/O=Open

Standard Knob OperatorCatalog Number 800H-NR2KF4PPXX

Contac t TypeContact Location Operator

PositionOperator

TypeStandard Knob

Contact TypeActuator

Color Contact

TypeM=MaintainedS=Spring Return Catalog Number �

WhiteWhit

AB

XO

OX

OO

OO

M M M M 800H-NR2KF4PPXXWhiteBlack

BA

OO

XO

OO

OX

S�M M M 800H-NR3KF4PPXXBlackBlack

AB

OO

OO

OX

XO M M M�S 800H-NR9KF4PPXX

2 N OWhiteWhit

AB

XO

XO

OX

OO

M M M M 800H-NR2KG4PPXX2 N.O. -2 N.C.

WhiteBlack

BA

OX

OO

XO

OO

S�M M M 800H-NR3KG4PPXX2 N.C. BlackBlack

AB

XO

OO

OO

OX M M M�S 800H-NR9KG4PPXX

WhiteWhit

AB

OX

OX

XO

XO

M M M M 800H-NR2KK4PPXXWhiteBlack

BA

XX

XO

OO

OX

S�M M M 800H-NR3KK4PPXXBlackBlack

AB

XO

OX

OX

XO M M M�S 800H-NR9KK4PPXX

4 Position Selector Switch Units, Non-Illuminated ( Type 4/13)

Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Note: X=Closed/O=Open

Standard Knob OperatorCatalog Number 800T-N2KF4BP

Contac t TypeContact Location Operator

PositionOperator

TypeStandard Knob

Contact TypeActuator

Color Contact

TypeM=MaintainedS=Spring Return Catalog Number �

— — — — — —M M M M 800T-N2KF4

No Contacts——

——

——

——

——

—— S�M M M 800T-N3KF4

— — — — — —M M M�S 800T-N9KF4

White A X O O O M M M M 800T-N2KF4BP2 N.O. -2 N.C.

WhiteWhiteBlack

ABA

XOO

OXO

OOO

OOX

S�M M M 800T-N3KF4BP2 N.C. BlackBlack

AB

OO

OO

OX

XO M M M�S 800T-N9KF4BP

Page 18: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-381� Prices – Consult Sales Office or price list

4 Position Selector Switch Units, Non-Illuminated

800 T–N 2 KF4 BPa b c d e

800 H–NR 2 KF4 P P X Xa b c d e1 f1 g1 � h1 �a

Operator TypeCode Description �

T-N NEMA 4/13 4 Position

H-NR NEMA 4/4X4 Position

bKnob Insert Colors

Code Color �

Blank White

A Red

B Green

C Blue

E Yellow

F Orange

X Packet of ColorInserts �

Metal Wing Lever ColorsCode Color �

A Red

G Gray

cOperator Function and

Knob Type

Standard Knob

Code Operator Function �

2 Maintained

3 Spring Return fromPosition 1 to Position 2

9 Spring Return fromPosition 4 to Position 3

Knob Lever (Type 4/13 Only)

Code Operator Function �

17 Maintained

29 Spring Return fromPosition 1 to Position 2

30 Spring Return fromPosition 4 to Position 3

Metal Wing Lever (T ype 4/13 Only)

Code Operator Function �

11 Maintained

13 Spring Return fromPosition 1 to Position 2

14 Spring Return fromPosition 4 to Position 3

dCam Option

Code Description �

KF4 “F” Cam

KG4 “G” Cam

KK4 “K” Cam

KM4 “M” Cam

KP4 “P” Cam

eTraditional Contact Blocks

(Type 4/13) �Sealed Switch

Code Description �

BP 2 N.O. - 2 N.C.

Stackable Sealed SwitchCode Description �

BY 2 N.O. - 2 N.C.

HY 3 N.O. - 3 N.C.

CY 4 N.O. - 4 N.C.

Logic ReedCode Description �

BR 2 N.O. - 2 N.C.

HR 3 N.O. - 3 N.C.

CR 4 N.O. - 4 N.C.

Note: See Table 1 for Target table selection.

e1,f1,g1,h1Modular Contact Blocks

(Type 4/4X) �Sealed Switch (Modular Suffix)

Code Description �

R 1 N.O.

S 1 N.C.

P 1 N.O. - 1 N.C.

X No Contact

Stackable Sealed Switch(Modular Suffix)

Code Description �

5 1 N.O.

6 1 N.C.

8 2 N.O.

9 2 N.C.

7 1 N.O. - 1 N.C.

Logic Reed (Modular Suffix)Code Description �

V 1 N.O.

W 1 N.C.

Y � 2 N.O.

Z 2 N.C.

T 1 N.O. - 1 N.C.

Note: See Table 2 for Modular Target tableselection.

Table 1. Cam and Contact Block Functionality Table

Contact Block ContactCk

Cam CodesNote : W=White/B=Black. X=Closed/O=Open.

Contact BlockSuffix Code

ContactBlockSide

kt KF4 KG4 KK4 KM4 KP4 KN4Suffix Code Sidets

WhiteA X O O O X X O O O O X X X O O O O O O X O X O O

BR/BP/BY

WhiteB O X O O O O X O X X O O O X X O O X O O O O O X

CR/CYHR/HY

BR/BP/BY

BlackA O O O X X O O O X O O X O O O X O O X X O O X O

CR/CY BlackB O O X O O O O X O X X O O X O O X O O O X O O O

WhiteA X O O O X X O O O O X X X O O O O O O X O X O O

WhiteB O X O O O O X O X X O O O X X O O X O O O O O X

BlackA O O O X X O O O X O O X O O O X O O X X O O X O

BlackB O O X O O O O X O X X O O X O O X O O O X O O O

Table 2. Selector Switch Cam Targets Table 3. Contact Block Reduction Rules

Cam DescriptionNote : W=White/B=Black. Contact Block SubstitutionCam Descr ipt ionNote : W=White/B=Black.

X=Closed/O=Open. Sealed Switch �

Target KF4 KG4 KM4 KP4 KK4 Combination Substitute Code

Contact Block Side R+S P

W B W B W B W B W B Logic Reed �X O O O R, V, 5 — — R,V,5 R,V,5 — — S,W,6 — — Combination Substitute Code

O X O O S,W,6 — — — — S,W,6 S,W,6 — — — V+V Y

O O X O — S,W,6 S,W,6 — — — — — — — W+W Z

O O O X — R,V,5 — S,W,6 — R,V,5 R,V,5 — — — V+W T

X X O O — — R,V,5 — — — — — S,W,6 — Stackable Sealed Switch �O X X O — — — — S,W,6 — — — — S,W,6 Combination Substitute Code

O O X X — — — — — — — R,V,5 R,V,5 — 5 + 6 7

X O O X — — — — — — — — — R,V,5 5 + 5 8

6 + 6 9

� Positions “g 1” and “h 1” must be filled with an “X” for sealed switch contact blocks.� Packet of color inserts includes one of each color except orange. � See Table 1. � See Table 2.� 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.���Contacts must be on the same side to substitute.

Page 19: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-382 � Prices – Consult Sales Office or price list

Pilot Light UnitsLegend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389

Transformer Type Pilot LightCatalog Number 800H-PR16R

Push-To-Test Pilot LightCatalog Number 800H-PRT16RAP

Lamp Type Volts ColorPilot Light Push- To-Test Dual Input

Lamp Type Volts ColorCatalog Number � Catalog Number � Catalog Number �

Full120 AC

RedGreenAmber

800H-QR10R800H-QR10G800H-QR10A

800H-QRT10RAP800H-QRT10GAP800H-QRT10AAP

800H-PRD16R800H-PRD16G800H-PRD16A

Incan-descent

FullVoltage �

24 AC/DCRed

GreenAmber

800H-QR24R800H-QR24G800H-QR24A

800H-QRT24RAP800H-QRT24GAP800H-QRT24AAP

800H-PRD24R800H-PRD24G800H-PRD24A

Trans-former � 120 AC

RedGreenAmber

800H-PR16R800H-PR16G800H-PR16A

800H-PRT16RAP800H-PRT16GAP800H-PRT16AAP

800H-PRDT16R800H-PRDT16G800H-PRDT16A

Full120 AC

RedGreenAmber

800H-QRH10R800H-QRH10G800H-QRH10A

800H-QRTH10RAP800H-QRTH10GAP800H-QRTH10AAP

800H-QRDL16R800H-QRDL16G800H-QRDL16A

LED �

FullVoltage

24 AC/DCRed

GreenAmber

800H-QRH24R800H-QRH24G800H-QRH24A

800H-QRTH24RAP800H-QRTH24GAP800H-QRTH24AAP

800H-QRDL24R800H-QRDL24G800H-QRDL24A

Trans-former 120 AC

RedGreenAmber

800H-PRL16R800H-PRL16G800H-PRL16A

800H-PRTL16RAP800H-PRTL16GAP800H-PRTL16AAP

800H-PRDTL16R800H-PRDTL16G800H-PRDTL16A

� Full Voltage Dual Input units are Diode Type. � Transformer Dual Input units are Transformer-Relay Type.

� For High Visibility 28 chip LED, change the letter “L” to “H” .

Typical Pilot Light Wiring DiagramsSee applicable Codes and Laws

Push- To-Test Pilot Light Device Schematic Dual Input Diode Pilot Light Device Schematic

Dual Input Pilot LightTypical Application Wiring Diagram

Dual Input Pilot LightTransformer Type Device Schematic

�� �

�� ��������

��� �����

������

���� ����� �� ��

���

���

���

�� �����

���

���

���

���

���

���

���

�������

��� �����

������

��� ��

������

����

����

Page 20: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

(Pilot Light)

(Push-to-Test)

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-383� Prices – Consult Sales Office or price list

Pilot Light Units

800 H – QR L 24 Ra b c d e f

800 T – P T 16 R APa b c d e f g

aOperator Type

Code Description �

T NEMA Type 4/13

H NEMA Type 4/4X

bPower Module T ype

NEMA Type 4/13

Code Description �

P Transformer(or Dual Input)

Q Full Voltage (or Resistor)

R Neon �

NEMA Type 4/4X

Code Description �

PR Transformer

QR Full Voltage (orResistor)

RR Neon �

cLamp Test Options

Code Description �

Blank No Test Option

T Push-to-Test

D Dual Input-Diode

DT Dual InputTransformer Relay

Note: Push-to-Test Pilot Light can besupplied with a factory jumpered800T-XAP or 800T-XAR, 1 N.O. - 1 N.C.Contact Block.

dIllumination Options

Transformer

Code Description �

Blank Standard Pilot Light

F Flashing Lamp �

H LED Cluster �

L LED �

Full Voltage

Code Description �

Blank Standard Pilot Light

F Flashing Lamp �

H LED Cluster ��

L LED ��

Resistor

Code Description �

Blank No Options

Neon

Code Description �

Blank No Options

eVoltage

Transformer

Code Description �

36 48V AC 50/60 Hz

16 120V AC 50/60 Hz

26 240V AC 50/60 Hz

76 277V AC 50/60 Hz

46 480V AC 50/60 Hz

56 600V AC 50/60 Hz

Full Voltage

Code Description �

06 6V AC/DC

12 12V AC/DC

24 24V AC/DC

10 120V AC/DC

20 240V AC/DC

Resistor

Code Description �

11 120V AC/DCResistor

Neon

Code Description �

10 120V AC/DC

20 240V AC/DC

Dual Input

Code Description �

16 120V AC 50/60 Hz

24 24V AC/DC50/60 Hz �

fLens Color

Plastic

Code Color �

Blank No Lens

A Amber

B Blue

C Clear

G Green

R Red

W White

Glass �

Code Color �

D Amber

E Blue

F Clear

H Green

J Red

K White

gContact Block �

Sealed Switch

Code Description �

AP 1 N.O. - 1 N.C.

Stackable Sealed Switch

Code Description �

AY 1 N.O. - 1 N.C.

Logic Reed

Code Description �

AR 1 N.O. - 1 N.C.

� Neon is only available in amber or clear.� Flashing lamps only available in 6V Full Voltage units and all Transformer units.� LEDs are only available in red, green and amber; lens color must match LED color.� Use only with 6V AC, 24V AC/DC and 120V AC Full Voltage units.� Dual Input Diode only.� Glass lens available on 800T Pilot Lights only. Not available on Push-To-Test or Type 4/4X units.� Push-to-Test Units only.

Page 21: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-384 � Prices – Consult Sales Office or price list

Custom Built StationsDescriptionThe price tables on Pages 11-366 and11-367 list the most commonly usedPush Button Stations. Stations not listedin the price tables may be ordered ascustom built stations.

PricingThe price for a custom built station is theprice of the enclosure, plus the price ofthe units and accessories to be installedin the enclosure.

Catalog NumberThe catalog number used to identifycustom built Bulletin 800R Push ButtonStations, which are built at the factory,will be catalog numbers listed for theenclosure only, except letter “W” will besubstituted for the letter “Z” and with astation serial number.

Ordering InformationThe following information is requiredwhen ordering custom built push buttonstations.1. Catalog number of enclosure.2. Catalog number of control units.3. Legend plate catalog number and/or

marking for each unit.4. Specify vertical or horizontal

mounting.5. Specify desired operator mounting

sequence. Inclusion of a sketch isrecommended. If no information isgiven, best judgement will be used.

Enclosures Only

Stainless SteelCatalog Number 800R-2HZ4

ROSITE Glass PolyesterCatalog Number 800R-2HZ4R

Die CastCatalog Number 800R-2TZ

Units�Die Cast

(NEMA Type 4/13)Stainless Steel(NEMA Type 4)

ROSITE Glass Polyester(NEMA Type 4/4X)Units�

Catalog Number � Catalog Number � Catalog Number �

1 800R-1TZ 800R-1HZ4 800R-1HZ4R

2 800R-2TZ 800R-2HZ4 800R-2HZ4R

3 800R-3TZ 800R-3HZ4 800R-3HZ4R

4 800R-4TZ 800R-4HZ4 800R-4HZ4R

5 — 800R-5HZ4 800R-5HZ4R

6 800R-6TZ 800R-6HZ4 800R-6HZ4R

� Number of units that can be mounted in enclosure.

Note: Enclosure and conduit dimensions are detailed on Page 11-389.

Page 22: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-385� Prices – Consult Sales Office or price list

Modifications and AccessoriesContact BlocksPackaged in kit form for field installation. All necessary mounting hardware is provided with each contact block kit. Contactratings are listed on Page 11-365. Sealed switch contact blocks are limited to two blocks per unit maximum. Logic Reed blocksand Stackable Sealed Switch blocks may be configured with four blocks per unit (two blocks on each side).

Logic Reed Block Sealed Switch Block Stackable Sealed Switch Block

N mber of ContactsLogic Reed Block � Sealed Switch Block � Stackable Sealed Switch Block �

Number of ContactsCatalog Number � Catalog Number � Catalog Number �

1 N.O. 800T-XD1R 800T-XD1P 800T-XD1Y

1 N.C. 800T-XD2R 800T-XD2P 800T-XD2Y

1 N.O. - 1 N.C. 800T-XAR 800T-XAP 800T-XAY

2 N.O. 800T-XA2R — 800T-XA2Y

2 N.C. 800T-XA4R — 800T-XA4Y

� A Bulletin 800T or 800H operator using Sealed Switch, Stackable Sealed Switch, and Logic Reed contact blocks and installed in a suitableenclosure are U.L. Listed as suitable for use in Class I, Division 2 Hazardous locations.

Approximate DimensionsDimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

���������������

�����������

���� �� ���

�����������

��� �����

������������

����������

Logic Reed Contact Block11/8 (28.6) Deep

Sealed Switch Block2 (50.8) Deep

������ �������

Stackable Sealed Switch Block1.58 (40.1) Deep

������������������

���������������������������

�����

����������������

����������������

�������

� Dimension shown is for Push Buttons. Selector Switch dimension is 129/32 (48.4). Cylinder Lock Selector Switch is 21/32 (51.6).� Dimension shown is for Push Buttons. Selector Switch dimension is 223/32 (69.1). Cylinder Lock Selector Switch is 227/32 (72.2).

For Information on Additional Accessories – Refer to Bulletin 800T, Bulletin 800H NEMA Type 4X and Bulletin 800H NEMA Type 7 & 9 Sections.

Page 23: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-386 � Prices – Consult Sales Office or price list

Conversion TablesOrdering InformationTo order Division 2 rated HazardousLocation Push Buttons:1. Refer to the 800T/800H section to

determine the appropriate operatorfor your application.

2. Match the 800T/800H operator typewith the corresponding table in the800R section.

3. Using the Catalog Number of the800T/800H operator determined inStep 1, substitute the StandardContact Block Suffix Code with therequired Sealed Switch or LogicReed Contact Block Suffix Code.

Ordering ExampleTo convert an 800T Momentary ContactNon-Illuminated Push Button to aMomentary Contact Non-IlluminatedPush Button with a Sealed SwitchContact Block, refer to the 800T section,Page 11-8. Determine theappropriate operator type and CatalogNumber for your application. When youhave determined the operator type andCatalog Number, refer to thecorresponding table in the 800R section,Page 11-387. Substitute the StandardContact Block Suffix Code with theSealed Switch Contact Block SuffixCode. Example: Catalog Number800T-A1A becomes 800T-A1AP.

Momentary Push Buttons, Non-Illuminated and IlluminatedIncludes the following operators: Momentary Contact/Cylinder Lock/Padlocking Mushroom Head/Wobble Stick

ContactArrangement

Sealed Switch ContactBlock

Stackable SealedSwitch Contact Block

Logic Reed ContactBlock

ArrangementSuffix Code � Suffix Code � Suffix Code �

1 N.O. D1P D1Y D1R

1 N.C. D2P D2Y D2R

2 N.O. A2P � A2Y A2R

2 N.C. A4P � A4Y A4R

1 N.O. - 1 N.C. AP AY AR

2 N.O. - 2 N.C. BP � BY BR

3 N.O. - 3 N.C. — HY � HR �

4 N.O. - 4 N.C. — CY � CR �

��Not valid with Illuminated Push Buttons.

Mechanicall y Interlocked, Maintained Push Button Units

ContactArrangement

Sealed Switch ContactBlock

Stackable SealedSwitch Contact Block

Logic Reed ContactBlock

ArrangementSuffix Code � Suffix Code � Suffix Code �

1 N.O. D1P D1Y D1R

1 N.C. D2P D2Y D2R

2 N.O. — A2Y A2R

2 N.C. — A4Y A4R

1 N.O. - 1 N.C. AP AY AR

2 N.O. - 2 N.C. BP BY BR

Page 24: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-387� Prices – Consult Sales Office or price list

Conversion Tables – Cont’d2-Position Push-Pull and Push-Pull Twist/Release Units Non-Illuminated and Illuminated

OperatorPosition

Contact

Sealed SwitchContact Block

Stackable SealedSwitch Contact

Block

Logic ReedContact Block

Out In

ContactArrangement

SuffixCode �

SuffixCode �

SuffixCode �

O O 1 N.O. D1P D1Y D1R

X O 1 N.C.L.B. D2P � — D2R �

OX

XO 1 N.O. - 1 N.C.L.B AP � — AR �

OO

XX 2 N.O. A2P A2Y A2R

XX

OO 2 N.C.L.B. A4P �� — A4R �

��Standard N.C. contacts are substituted for N.C.L.B. contacts.

��Only valid with Non-Illuminated Operators.

3-Position Push-Pull Units Non-Illuminated and Illuminated

Operator Position

Contact

Sealed SwitchContact Block

Stackable SealedSwitch Contact

Block

Logic ReedContact Block

Out Center In

ContactArrangement

SuffixCode �

SuffixCode �

SuffixCode �

OX

OO

XO 1 N.O. - 1 N.C. AP AY AR

2-, 3- and 4-Position Selector Switch Units, Non-Illuminated (Excluding Bulletin 800H NEMA Type 7 & 9)

ContactArrangement

Sealed Switch ContactBlock

Stackable SealedSwitch Contact Block

Logic Reed ContactBlock

ArrangementSuffix Code � Suffix Code � Suffix Code �

1 N.O. D1P D1Y D1R

1 N.C. D2P D2Y D2R

2 N.O. RRXX A2Y A2R

2 N.C. SSXX A4Y A4R

1 N.O. - 1 N.C. AP AY AR

2 N.O. - 2 N.C. BP BY BR

3 N.O. - 3 N.C. — HY HR

4 N.O. - 4 N.C. — CY CR

2 N.O. - 2 N.C. PPXX 77XX TTXX

4 N.O. - 4 N.C. — 7777 TVXX

Page 25: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-388 � Prices – Consult Sales Office or price list

Conversion Tables – Cont’d

1-2-3-4 Way Toggle Switches (800T only)

ContactArrangement

Sealed Switch ContactBlock �

Stackable SealedSwitch Contact Block �

Logic Reed ContactBlock

ArrangementSuffix Code � Suffix Code � Suffix Code �

1 N.O. R 5 V

1 N.C. S 6 W

1 N.O.E.M. — — —

1 N.C.L.B. — — —

1 N.O. - 1 N.C. P 7 T

1 N.C.L.B. - 1 N.O. — — —

1 N.C.L.B. - 1 N.C. — — —

2 N.O. — 8 Y

2 N.C. — 9 Z

� For sealed switch contacts, the third and fourth positions of the configurated contact blocks must be filled withthe letter “X” (no contact block). Example: Catalog Number 800T-T2H2PPXX incorporates an “X” in the thirdand fourth positions.

Push-To-Test Pilot Light Units

Contact ArrangementSealed Switch Contact

BlockStackable Sealed

Switch Contact BlockContact ArrangementSuffix Code � Suffix Code �

Blank (1 N.O. - 1 N.C.) AP AY

Page 26: Bulletin 800R NEMA Style Push Buttons Hermetically Sealed ......DC 150 DC-13 Q150 24-150 0-24 69VA 2.5A Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15A Should

��Selector Switch is 15/32 (29.4) maximum; Pilot Light is 17/32 (31).

� Selector Switch is 13/32 (27.8) maximum; Pilot Light is 15/32 (29.4) maximum.

�'����� ���

�'�������

��

�'� ����

������� �����%�

�'�����������

�������

���

�'���������� �

�������������%��

�'�������� �

�'����� �� �

�'�����������

�������

��������%���������

������� ���

� �� ���������

�'���������������

�'��������

�'����������

����������

����������

�%#� ��������� �&

�'����������

�'����������

�'����������������

�'���������

�'��������

������

������"����

����������

�'�������� ��

�'���������������

�� ��$��!��� �

NEMA Type 4Stainless Steel

Watertight/Dust- TightEnclosure

NEMA Type 4XROSITE Glass Polyester

Watertight/Corrosion ResistantEnclosure

NEMA Type 4/13Watertight/Oiltight

Cast AluminumEnclosure

Operator Extension in Front of Panel �

� Selector Switch is 17/32 (30.9) maximum; Pilot Light is 19/32 (32.5).

NEMA Type 4/4XBooted

Flush & ExtendedHead Push Button

NEMA Type4/4X

Pilot Light

NEMA Type 4/13and Type 4/4X

BootlessFlush & ExtendedHead Push Button

NEMA Type4/13

Pilot Light

NEMA Type 4/13and 4 & 4X

Standard KnobSelector Switches

Mounting Instructions(For Panel Mounting)

� Minimum vertical spacing dimension for Jumbo Legend Plate is 215/32 (62.7).

��See Pages 11-50 thru 11-53 for additional NEMA Type 4/13 outlines and Pages 11-95 thru 11-98 for additional NEMA

Bulletin 800R

NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations

11-389

Approximate Dimensions and Shipping WeightsDimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

DimensionNumber of Units

Dimension1 2 3 4 5 6

NEMA Type 4

A 55/32 (135) 7 (178) 827/32 (225) 1011/16 (271) 1217/32 (318) 143/8 (360)

B 613/32 (163) 81/4 (210) 101/8 (257) 1131/32 (304) 141/32 (359) 157/8 (403)

Pipe Tap Size 3/4 1

NEMA Type 4X

A 41/2 (114) 41/2 (114) 61/4 (159) 8 (203) 121/8 (308) 121/8 (308)

B 71/32 (181) 71/32 (181) 823/32 (221) 1021/32 (271) 147/8 (378) 147/8 (378)

C 57/8 (149) 57/8 (149) 79/16 (192) 91/2 (241) 131/2 (343) 131/2 (343)

Pipe Tap Size 3/4 1

NEMA Type 4/13

A 23/4 (69.8) 41/2 (114) 61/4 (159) 8 (203) — 121/8 (308)

B 43/16 (106) 57/8 (149) 79/16 (192) 91/2 (241) — 131/2 (343)

ConduitOpening

3/4”-14 N.P.T. —1”-111/2N.P.T.