Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-364
Bulletin 800R
NEMA StyleHazardous Location
Push Buttons
Classes I and IIDivision 2 Only
30.5mmMounting Hole
NEMA Types4/13 and 4/4X
Stations andOperators
TABLE OF CONTENTSDescription Page Description PageTechnical Data 11-365. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stations
Complete Assembled, Metallic Enclosures 11-366. . . . . . . . . . . . . . . Complete Assembled, Non-Metallic Enclosures 11-367. . . . . . . . . .
Push ButtonsMomentary Contact, Non-Illuminated 11-368. . . . . . . . . . . . . . . . . . . Momentary Contact, Flip Lever 11-370. . . . . . . . . . . . . . . . . . . . . . . . Mechanically Interlocked Maintained 11-370. . . . . . . . . . . . . . . . . . . . Momentary Contact, Illuminated 11-372. . . . . . . . . . . . . . . . . . . . . . . .
Push-Pull, Non-Illuminated2 Position Push-Pull/Twist 11-374. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position Push-Pull 11-374. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Push-Pull, Illuminated2 Position Push-Pull/Twist 11-376. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position Push-Pull 11-376. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selector Switches, Non-Illuminated2 Position 11-378. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Position 11-378. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Position 11-380. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pilot LightsStandard 11-382. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Push-To-Test 11-382. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dual Input 11-382. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Pilot Light W iring Diagrams 11-382. . . . . . . . . . . . . . . . . . . . . Custom Built Stations 11-384. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enclosures Only 11-384. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modifications and Accessories
Contact Blocks 11-385. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conversion Tables 11-386. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions 11-389. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ELECTRICAL RATINGSContact RatingsRefer to the Contact Ratings tables to the right.Dielectric Strength2200 Volts for one minute1300 Volts for one minute (Logic Reed)Electrical Design Life Cycles1,000,000 at maximum rated load200,000 at maximum rated load (Logic Reed)
MECHANICAL RATINGSVibration10-2000 Hz 1.52mm displacement (peak-to-peak)Max./10G Max. (except Logic Reed)Shock1/2 cycle sine wave for 11 milliseconds � 25G (contact fragility)and no damage at 100GDegree of ProtectionNEMA Type 4/4X, 4/13; Watertight/Corrosion-ResistantIEC 529 IP 66/65Mechanical Design Life CyclesPush Buttons (Momentary, Non-illuminated): 10,000,000 min.
(Momentary, Illuminated): 250,000 min.(Push-Pull / Twist to Release): 250,000 min.
Selector Switches (Non-illuminated): 1,000,000 min.(Illuminated): 200,000 min.
All other devices: 200,000 min.Contact OperationLogic Reed & Sealed Switch Contact Blocks:
Single break magneticTypical Operating ForcesOperators without contact blocks:
Flush, Extended, Standard Mushroom,Jumbo Plastic Mushroom: 2 lbs. Max.Maintained Selector Switch: 3.6 in. lbs. maximum
Spring Return Selector Switches:3.6 in. lbs. to stop0.2 in. lbs. to return
Illuminated Push Buttons and Push-to-Test Pilot Lights:5 lbs. maximum
3 Position Push-Pull:8 lbs. maximum push to in position or pull to center position (15 lbs.maximum pull to out position)
Push-Pull and Push-Pull/Twist:9 lbs. maximum push or pull30 in. oz. maximum twist, 6 in. oz. minimum return
Contact Blocks:Logic Reed: 1 lb. maximumSealed Switch: 3 lbs. maximum at 0.205” plunger travel
ENVIRONMENTTemperature RangeOperating: +14°F to +131°F (-10°C to +55°C)Storage: -40°F to +185°F (-40°C to +85°C)Note: Operating temperatures at -10°C are based on theabsence of freezing moisture and liquids. Contact your localAllen-Bradley sales office for use in lower temperatureapplications.Humidity50% at +104°F (+40°C)
� Performance Data — See Page Important-2.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-365
Technical Data �
Control StationsBulletin 800R Control Stations are designed for Division 2hazardous locations. They consist of Bulletin 800H (NEMAType 4/4X) or Bulletin 800T (NEMA Type 4/13) operators withsealed contact blocks. Bulletin 800R units are available asfactory assembled stations or as components for field assembly.
Hazardous LocationsSince the contacts are enclosed in a hermetically sealedchamber, the contact block is suitable for use in Class I and II,Division 2, Groups A, B, C, D, F and G hazardou s locationsand i s listed by Underwriters Laboratories for this class ofservice. Complete stations as shown on Page 11-366 can beused for Class I and II Division 2 applications. The individualcomponents on Pages 11-368 thru 11-383 are also suitable forClass I and II Division 2 locations providing they are suitablymounted by the customer in an enclosure as required for theapplication and by applicable codes and laws.Per National Electrical Code: Zone 2. In Class I, Zone 2locations, all wiring methods permitted for Class I, Division 2,Class I, Division 1 or Division 2, and Class I, Zone 0 or Zone 1locations, including requirements for sealing, shall be permitted.NOTE: Allen-Bradley logic reed contact blocks are alsolisted by Underwriters Laboratories for the Division 2hazardous locations listed above.
The complete stations and individual compo-nents listed herein ARE NOT SUITABLE FORUSE IN CLASS I AND II DIVISION 1 HAZ-ARDOUS LOCATIONS. For Class I and II Divi-sion 1 hazardous locations, order Bulletin 800HNEMA Type 7 & 9 stations and units.
! CAUTION:
Sealed Switch Contact RatingsMaximum continuous current Ith 5 Amperes. Bulletin 800T and800H units have control circuit ratings with sealed switchcontact blocks as follows:
Max.Opertnl.
UtilizationCategory
Rated OperationalCurrentsOpertnl .
Volts Ue IEC NEMA Volts Ue Make Break
AC 600 AC-15 B600120-600
0-1203600VA
30A360VA
3A
DC 300 DC-13 P30024-300
0-24138VA5.0A
Stackable Sealed Switch Contact RatingsMaximum continuous current Ith 3 Amperes. Bulletin 800Tand 800H units have control circuit ratings with sealedswitch contact blocks as follows:
Max.Opertnl.
UtilizationCategory
Rated OperationalCurrentsOpertnl .
Volts Ue IEC NEMA Volts Ue Make Break
AC 300 AC-15 C300120-300
0-1201800VA
15A180VA1.5A
DC 150 DC-13 Q15024-150
0-2469VA2.5A
Logic Reed Contact RatingsMaximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15AShould only be used with resistive loads
ApprovalsUL Listed: – File E10314 – Guide NOIVCSA Certified: LR11924IEC Compliance
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-366 � Prices – Consult Sales Office or price list
Complete Assembled Stations, Metallic Enclosures NEMA Type 4
Dimensions – Page 11-389
Surface MountCatalog Number 800R-1TA
Booted Operator StationCatalog Number 800R-1HA4T
Bootless Operator StationCatalog Number 800R-1HA4TL
Contact B tton Type/ Legend
SteelEnclosures � Stainless Steel Enclosures �
Operator ContactSymbol
Button Type/Color
LegendMarking Surface Mount Booted
Operator StationBootless
Operator StationCatalog No. � Catalog No. � Catalog No. �
Flush/Green START 800R-1TB 800R-1HB4T 800R-1HB4TLOnePush
1 N.O. - Extended/Red STOP 800R-1TA 800R-1HA4T 800R-1HA4TLPush
Button
1 N.O. 1 N.C. Mushroom/Red EMRG. STOP 800R-1TKG — 800R-1HK4TLGButton
Flush/Black No Legend 800R-1TX 800R-1HX4T 800R-1HX4TL
Flush/Green START800R 2TA 800R 2HA4T 800R 2HA4TLTwo
Push1 N.O. -
Flush/GreenExtended/Red
STARTSTOP 800R-2TA 800R-2HA4T 800R-2HA4TL
PushButtons
1 N.O. 1 N.C.Each Flush/Black
No Legends 800R 2TX 800R 2HX4T 800R 2HX4TLButtons EachButton
Flush/BlackFlush/Black No Legends 800R-2TX 800R-2HX4T 800R-2HX4TL
Red120V AC Red No Legend
OneRed
120V AC RedFlush/Green
No LegendSTART 800R-2TAR 800R-2HAR4T 800R-2HAR4TLOne
Pilot LightFlush/Green
Extended/RedSTARTSTOP
800R 2TAR 800R 2HAR4T 800R 2HAR4TLPilot LightTwo Push 1 N.O. -
1 N C120V AC RedTwo Push
Buttons 1 N.C.Each120V AC RedFlush/Black No Legends 800R-2TXR 800R-2HXR4T 800R-2HXR4TLEach
ButtonFlush/BlackFlush/Black
No Legends 800R 2TXR 800R 2HXR4T 800R 2HXR4TL
3 PositionSelector 1 N.O. -
MaintainedHAND OFF
AUTO 800R-R3TA — 800R-R3HA4TLSelectorSwitch
1 N.O. 1 N.C. Maintained No Legend 800R-R3TX — 800R-R3HX4TL
One PushButton
Maintnd.
1 N.O. -1 N.C.
Push-Pull/TwistRed EMRG. STOP 800R-1TAM — 800R-1HAM4TL
Two PushButtons 1 N.O. -
Flush/GreenExtended/Red
STARTSTOP 800R-2TAM 800R-2HAM4T 800R-2HAM4TL
ButtonsMaintnd.
1 N.O. 1 N.C. Flush/Black
No Legends 800R 2TXM 800R 2HXM4T 800R 2HXM4TLMaintnd. Flush/BlackFlush/Black No Legends 800R-2TXM 800R-2HXM4T 800R-2HXM4TL
� NEMA Type 4/13.
� NEMA Type 4 only.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-367� Prices – Consult Sales Office or price list
Complete Assembled Stations, Non-Metallic Enclosures NEMA Type 4/4X/13
Dimensions – Page 11-389
Booted Operator StationCatalog Number 800R-1HA4R
Bootless Operator StationCatalog Number 800R-1HA4RL
Contact B tton Type/ LegendROSITE Glass Polyester Enclosures
Operator ContactSymbol
Button Type/Color
LegendMarking Booted Operator Station Bootless Operator Stationp Symbol Color Marking
Catalog Number � Catalog Number �
Flush/Green START 800R-1HB4R 800R-1HB4RLOnePush
1 N.O. - Extended/Red STOP 800R-1HA4R 800R-1HA4RLPush
Button
1 N.O. 1 N.C. Mushroom/Red EMERG. STOP — 800R-1HK4RLGButton
Flush/Black No Legend 800R-1HX4R 800R-1HX4RL
Flush/Green START800R 2HA4R 800R 2HA4RLTwo
Push1 N.O. -
Flush/GreenExtended/Red
STARTSTOP 800R-2HA4R 800R-2HA4RL
PushButtons
1 N.O. 1 N.C.Each Flush/Black
No Legends 800R 2HX4R 800R 2HX4RLButtons EachButton
Flush/BlackFlush/Black No Legends 800R-2HX4R 800R-2HX4RL
Red120V AC Red No Legend
OneRed
120V AC RedFlush/Green
No LegendSTART 800R-2HAR4R 800R-2HAR4RLOne
Pilot LightFlush/Green
Extended/RedSTARTSTOP
800R 2HAR4R 800R 2HAR4RLPilot LightTwo Push 1 N.O. -
1 N C120V AC RedTwo Push
Buttons 1 N.C.Each120V AC RedFlush/Black No Legends 800R-2HXR4R 800R-2HXR4RLEach
ButtonFlush/BlackFlush/Black
No Legends 800R 2HXR4R 800R 2HXR4RL
3 PositionSelector 1 N.O. -
MaintainedHAND OFF
AUTO — 800R-R3HA4RLSelectorSwitch
1 N.O. 1 N.C. Maintained No Legend — 800R-R3HX4RL
One PushButton
Maintained
1 N.O. -1 N.C.
Push-Pull/TwistRed EMERG. STOP — 800R-1HAM4RL
Flush/Green START800R 2HAM4R 800R 2HAM4RLTwo Push
Buttons 1 N.O. -
Flush/GreenExtended/Red
STARTSTOP 800R-2HAM4R 800R-2HAM4RL
ButtonsMaintained
1 N.O. -1 N.C. Flush/Black
No Legends 800R 2HXM4R 800R 2HXM4RLMaintained C Flush/BlackFlush/Black No Legends 800R-2HXM4R 800R-2HXM4RL
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-368 � Prices – Consult Sales Office or price list
Momentary Contact Push Button Units, Non-IlluminatedLegend Plates – Pages 11-46,11-91Accessories – Page 11-385Dimensions – Page 11-389
Booted UnitCatalog Number 800H-R1D2P
Bootless Flush Head UnitCatalog Number 800H-AR1AP
Bootless Extended Head UnitCatalog Number 800H-BR6AP
Contact Type ButtonColor
Booted � BootlessFlush Head
BootlessExtended HeadContact Type Color
Catalog Number � Catalog Number � Catalog Number �
1 N.C.GreenBlackRed
800H-R1D2P800H-R2D2P800H-R6D2P
800H-AR1D2P800H-AR2D2P
—
800H-BR1D2P800H-BR2D2P800H-BR6D2P
1 N.O.GreenBlackRed
800H-R1D1P800H-R2D1P800H-R6D1P
800H-AR1D1P800H-AR2D1P
—
800H-BR1D1P800H-BR2D1P800H-BR6D1P
1 N.O. - 1 N.C.GreenBlackRed
800H-R1AP800H-R2AP800H-R6AP
800H-AR1AP800H-AR2AP
—
800H-BR1AP800H-BR2AP800H-BR6AP
2 N.O. - 2 N.C.GreenBlackRed
800H-R1BP800H-R2BP800H-R6BP
800H-AR1BP800H-AR2BP
—
800H-BR1BP800H-BR2BP800H-BR6BP
Note: For NEMA 4/13 metal products see page 11-369.
Bootless Guarded HeadCatalog Number 800H-GR1AP
Bootless Mushroom HeadCatalog Number 800H-DR6AP
Jumbo Mushroom HeadCatalog Number 800H-DR6JAP
Contact Type ButtonColor
BootlessGuarded Head
BootlessMushroom Head
JumboMushroom HeadContact Type Color
Catalog Number � Catalog Number � Catalog Number �
1 N.C.GreenBlackRed
800H-GR1D2P800H-GR2D2P
—
800H-DR1D2P800H-DR2D2P800H-DR6D2P
800H-DR1JD2P800H-DR2JD2P800H-DR6JD2P
1 N.O.GreenBlackRed
800H-GR1D1P800H-GR2D1P
—
800H-DR1D1P800H-DR2D1P800H-DR6D1P
800H-DR1JD1P800H-DR2JD1P800H-DR6JD1P
1 N.O. - 1 N.C.GreenBlackRed
800H-GR1AP800H-GR2AP
—
800H-DR1AP800H-DR2AP800H-DR6AP
800H-DR1JAP800H-DR2JAP800H-DR6JAP
2 N.O. - 2 N.C.GreenBlackRed
800H-GR1BP800H-GR2BP
—
800H-DR1BP800H-DR2BP800H-DR6BP
800H-DR1JBP800H-DR2JBP800H-DR6JBP
Note: For NEMA 4/13 metal products see page 11-369.� Green and black operators are flush; red units are extended head.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-369� Prices – Consult Sales Office or price list
Momentary Contact Push Button Units, Non-Illuminated
800 T – A 1 APa b c d e
aNEMA Type
Code Description �
T NEMA Type 4/13
H NEMA Type 4/4X
b
Operator TypeNEMA Type 4/13
Code Description �
A Flush Head �
B Extended Head
D Mushroom Head
DX Mushroom Head less Color Cap
NEMA Type 4/4X
Code Description �
AR Flush Head �
BR Extended Head
DR Mushroom Head
DRX Mushroom Head less Color Cap
GR Bootless Guarded Head
R Booted Head �
cColor Cap
Code Color �
Blank Used only when orderingOperator Type “DX”
1 Green
2 Black
3 Orange �
4 Gray �
5 White �
6 Red
7 Blue
9 Yellow
dSpecial Mushroom Head
Code Description �
Blank No Special Head
J Jumbo Mushroom Head — Plastic
L Jumbo Mushroom Head — Metal
Note: Special Mushroom Head options only apply to Mush-room Head operator Type Code “D” or “DR” . Special Mush-room Head option “L” only valid with NEMA 4/13 operatortype “D” .
eContact Blocks
Sealed Switch
Code Description �
Blank No Contacts
D1P 1 N.O.
D2P 1 N.C.
A2P 2 N.O.
A4P 2 N.C.
AP 1 N.O. - 1 N.C.
BP 2 N.O. - 2 N.C
Stackable Sealed Switch
Code Description �
D1Y 1 N.O.
D2Y 1 N.C.
A2Y 2 N.O.
A4Y 2 N.C.
AY 1 N.O. - 1 N.C.
BY 2 N.O. - 2 N.C
HY 3 N.O. - 3 N.C.
CY 4 N.O. - 4 N.C
Logic Reed
Code Description �
Blank No Contacts
D1R 1 N.O.
D2R 1 N.C.
A2R�� 2 N.O.
A4R 2 N.C.
AR 1 N.O. - 1 N.C.
BR 2 N.O. - 2 N.C.
HR 3 N.O. - 3 N.C.
CR 4 N.O. - 4 N.C.
� Red flush head operators are not recommended for Emergency Stop applications.� Green and black operators are flush underneath boots; red operators are extended.� Not available for booted operators.� 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-370 � Prices – Consult Sales Office or price list
Momentary Contact Flip Lever Operators — NEMA Type 4Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Flip Lever OperatorCatalog Number 800H-WK42AP
Flip Lever OperatorCatalog Number 800H-WK61AP
Contac t Type B tto n Color Hot Stamped Flip LeverContact Type Button Color Hot Stamped
Legend Marking Catalog Number �
Gray START 800H-WK42AP
1 N O 1 N CGray No Legend 800H-WK4AP
1 N.O. - 1 N.C.Red STOP 800H-WK61AP
Red No Legend 800H-WK6AP
Gray START 800H-WK42BP
2 N O - 2 N CGray No Legend 800H-WK4BP
2 N.O. - 2 N.C.Red STOP 800H-WK61BP
Red No Legend 800H-WK6BP
Mechanically Interlocked Maintained Push Button UnitsLegend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Bootless OperatorCatalog Number 800H-CRA22AP
Booted OperatorCatalog Number 800H-FRB16AP
Contac t ArrangementBooted Bootless
Contact ArrangementButton Type Color Button Type Color Button Type Color
Type Configuration/Position
Upper: FlushLower: Extended
GreenRed
Upper: FlushLower: Extended
GreenRed
Upper: FlushLower: Flush
BlackBlackType Position
Catalog Number � Catalog Number � Catalog Number �
1 N.O. -1 N.C.
800H-FRB16AP 800H-CRB16AP 800H-CRA22AP
2 N.O. -2 N.C. 800H-FRB16FP 800H-CRB16FP 800H-CRA22FP
Note: For NEMA 4/13 metal products see page 11-371.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-371� Prices – Consult Sales Office or price list
Momentary Contact Flip Lever Operators — NEMA Type 4
800H– WK 4 2 BPa b c d
aOperator Type
Code Description �
WK Flip Lever
bColor
Code Description �
4 Gray
6 Red �
cLegend Plate Marking
Code Marking �
Blank No Legend �
1 Stop
2 Start
dContact Blocks
Sealed Switch
Code Description �
Blank No Contacts
D1P 1 N.O.
D2P 1 N.C.
A2P 2 N.O.
A4P 2 N.C.
AP 1 N.O. - 1 N.C.
BP 2 N.O. - 2 N.C
Stackable Sealed Switch
Code Description �
D1Y 1 N.O.
D2Y 1 N.C.
A2Y 2 N.O.
A4Y 2 N.C.
d (cont’d)Contact Blocks
Stackable Sealed Switch
Code Description �
AY 1 N.O. - 1 N.C.
BY 2 N.O. - 2 N.C.
HY 3 N.O. - 3 N.C.
CY 4 N.O. - 4 N.C.
Logic Reed
Code Description �
Blank No Contacts
D1R 1 N.O.
D2R 1 N.C.
A2R 2 N.O. �
A4R 2 N.C.
AR 1 N.O. - 1 N.C.
BR 2 N.O. - 2 N.C.
HR 3 N.O. - 3 N.C.
CR 4 N.O. - 4 N.C.
Mechanically Interlocked Maintained Push Button Units
800 T – F A 2 6 APa b c d e f g
aNEMA Type
Code Description �
T NEMA Type 4/13
H NEMA Type 4/4X
bOperator TypeNEMA Type 4/13
Code Description �
F Vertical Mounting
G Horizontal Mounting
NEMA Type 4/4X
Code Description �
CR Bootless Operator
FR Booted Operator
cButton Position and Function
Upper or Left/Lower or Right
Code Description �
Blank Maintained/Maintained
Y Momentary/Maintained
Z Maintained/Momentary
dNEMA Type
Head Type 4/13 Upper or Left/Lower or Right
Code Description �
A Flush/Flush
B Flush/Extended
C Flush/Mushroom
D Mushroom/Mushroom
E Extended/Flush
F Flush/Cylinder Lock
G Mushroom/Flush
H Mushroom/Extended
J Extended/Extended
Head Type 4/4X Upper or Left/Lower or Right
Code Description �
A Flush/Flush
B Flush/Extended
E Extended/Flush
J Extended/Extended
e,fButton Color
Upper or Left/Lower or Right
Code Color �
1 Green
2 Black
3 Orange �
4 Gray �
e,fButton Color
Upper or Left/Lower or Right
Code Color �
5 White �
6 Red �
7 Blue
9 Yellow
gSealed Contact Blocks
Sealed Switch
Code Description �
D1P 1 N.O.
D2P 1 N.C.
AP 1 N.O. - 1 N.C.
FP 2 N.O. - 2 N.C.
Stackable Sealed Switch
Code Description �
D1Y 1 N.O.
D2Y 1 N.C.
AY 1 N.O. - 1 N.C.
FY 2 N.O. - 2 N.C.
Logic Reed
Code Description �
D1R 1 N.O.
D2R 1 N.C.
AR 1 N.O. - 1 N.C.
FR 2 N.O. - 2 N.C.
� Locking provision is supplied as standard on red units. � Legend plate not included but may be ordered as a separate item.� 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.� Not available with booted operators. � Red flush head operators are not recommended for Emergency Stop applications.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-372 � Prices – Consult Sales Office or price list
Momentary Contact Push Button Units, Illuminated
Extended Head Without GuardCatalog Number 800H-PRB16RAP
Extended Head With GuardCatalog Number 800H-PRA16RAP
Illuminated Mushroom HeadCatalog Number 800H-PRM16RAP
Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Lamp Type Volts ColorExtended Head Without Guard
Extended HeadWith Guard Mushroom Head
Lamp Type Volts ColorCatalog Number � Catalog Number � Catalog Number �
Full120 AC
RedGreenAmber
800H-QRB10RAP800H-QRB10GAP800H-QRB10AAP
800H-QRA10RAP800H-QRA10GAP800H-QRA10AAP
800H-QRM10RAP800H-QRM10GAP800H-QRM10AAP
Incan-descent
FullVoltage
24 AC/DCRed
GreenAmber
800H-QRB24RAP800H-QRB24GAP800H-QRB24AAP
800H-QRA24RAP800H-QRA24GAP800H-QRA24AAP
800H-QRM24RAP800H-QRM24GAP800H-QRM24AAP
Trans-former 120 AC
RedGreenAmber
800H-PRB16RAP800H-PRB16GAP800H-PRB16AAP
800H-PRA16RAP800H-PRA16GAP800H-PRA16AAP
800H-PRM16RAP800H-PRM16GAP800H-PRM16AAP
Full120 AC
RedGreenAmber
800H-QRBL10RAP800H-QRBL10GAP800H-QRBL10AAP
800H-QRAL10RAP800H-QRAL10GAP800H-QRAL10AAP
800H-QRML10RAP800H-QRML10GAP800H-QRML10AAP
LED4 Chip
FullVoltage
24 AC/DCRed
GreenAmber
800H-QRBL24RAP800H-QRBL24GAP800H-QRBL24AAP
800H-QRAL24RAP800H-QRAL24GAP800H-QRAL24AAP
800H-QRML24RAP800H-QRML24GAP800H-QRML24AAP
Trans-former 120 AC
RedGreenAmber
800H-PRBL16RAP800H-PRBL16GAP800H-PRBL16AAP
800H-PRAL16RAP800H-PRAL16GAP800H-PRAL16AAP
800H-PRML16RAP800H-PRML16GAP800H-PRML16AAP
LEDFull
120 ACRed
GreenAmber
800H-QRBH10RAP800H-QRBH10GAP800H-QRBH10AAP
800H-QRAH10RAP800H-QRAH10GAP800H-QRAH10AAP
800H-QRMH10RAP800H-QRMH10GAP800H-QRMH10AAP
LED28 Chip
HighVisibility
FullVoltage
24 AC/DCRed
GreenAmber
800H-QRBH24RAP800H-QRBH24GAP800H-QRBH24AAP
800H-QRAH24RAP800H-QRAH24GAP800H-QRAH24AAP
800H-QRMH24RAP800H-QRMH24GAP800H-QRMH24AAP
Visibility
Trans-former 120 AC
RedGreenAmber
800H-PRBH16RAP800H-PRBH16GAP800H-PRBH16AAP
800H-PRAH16RAP800H-PRAH16GAP800H-PRAH16AAP
800H-PRMH16RAP800H-PRMH16GAP800H-PRMH16AAP
Note: For NEMA 4/13 metal 30 mm operators see page 11-373.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-373� Prices – Consult Sales Office or price list
Momentary Contact Push Button Units, llluminated
800 T – P B L 16 R APa b c d e f g
aOperator Type
Code Description �
T NEMA Type 4/13
H NEMA Type 4/4X
bPower Module T ype
NEMA Type 4/13
Code Description �
P Transformer(or Dual Input)
Q Full Voltage(or Resistor)
R Neon �
NEMA Type 4/4X
Code Description �
PR Transformer(or Dual Input)
QR Full Voltage(or Resistor)
RR Neon �
cHead Type
Code Description �
A Extended Headwith Guard �
B Extended Headwithout Guard
M Mushroom
MJ Jumbo Mushroom
dIllumination Options
Transformer
Code Description �
Blank Standard Pilot Light
F Flashing Lamp �
H LED Cluster ��
L LED ��
Full Voltage
Code Description �
Blank Standard Pilot Light
F Flashing Lamp
H LED Cluster ��
L LED ��
Resistor
Code Description �
Blank No Options
Neon
Code Description �
Blank No Options
Dual Input
Code Description �
D Diode Type
T Transformer-RelayType
TH Transformer-RelayType w/LED Cluster
TL Transformer-RelayType w/LED
eVoltage
Transformer
Code Description �
36 48V AC 50/60 Hz
16 120V AC 50/60 Hz
26 240V AC 50/60 Hz
76 277V AC 50/60 Hz
46 480V AC 50/60 Hz
56 600V AC 50/60 Hz
Full Voltage
Code Description �
06 6V AC/DC
12 12V AC/DC
24 24V AC/DC
10 120V AC/DC
20 240V AC/DC
Resistor
Code Description �
11 120V AC/DCResistor
Neon
Code Description �
10 120V AC/DC
20 240V AC/DC
Dual Input
Code Description �
16 120V AC 50/60 Hz
24 24V AC/DC50/60 Hz �
fLens Color
Code Color �
X No Lens
A Amber
B Blue
C Clear
G Green
R Red
W White
gSealed Contact Blocks
Sealed Switch
Code Description �
D1P 1 N.O.
D2P 1 N.C.
AP 1 N.O. - 1 N.C.
X No Contacts
Stackable Sealed Switch
Code Description �
D1Y 1 N.O.
D2Y 1 N.C.
A2Y 2 N.O.
A4Y 2 N.C.
AY 1 N.O. - 1 N.C.
BY 2 N.O. - 2 N.C.
Logic Reed
Code Description �
D1R 1 N.O.
D2R 1 N.C.
A2R 2 N.O. �
A4R 2 N.C.
AR 1 N.O. - 1 N.C.
BR 2 N.O. - 2 N.C.
X No Contacts
� Neon is only available in amber or clear.� Red flush head operators are not recommended for Emergency Stop applications.� Flashing lamps are only available in 6V Full Voltage units and all Transformer units.� LEDs are only available in red, green and amber; lens color must match LED color.� Use only with 6V AC, 24V AC/DC and 120V AC Full Voltage units, and all Transformer units.� Dual Input diode only.� 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-374 � Prices – Consult Sales Office or price list
2 Position Push-Pull/ Twist Release Units, Non-Illuminated
Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389Note: A jumbo or large legend plate isrecommended, if space allows.
2 Position Push-Pull/TwistCatalog Number 800H-FRXT6D2P
Note: X=Closed/O=Open
Operator Position
Contact TypeMaintained Maintained
ButtonColor
Push-Pull/Twist Release
Out In Catalog Number �
N.C. X O Red 800H-FRXT6D2P
N.O. -N.C.
OX
XO Red 800H-FRXT6AP
N.C. -N.C.
XX
OO Red 800H-FRXT6A4P
Note: For NEMA 4/13 metal 30 mm operators see page 11-375.
3 Position Push-Pull Units, Non-Illuminated
Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389Note: A jumbo or large legend plate isrecommended, if space allows.
3 Position Push-PullCatalog Number 800H-FRXM6AP
Note: X=Closed/O=Open
Operator Position
Contact TypeMomentary Maintained Maintained
ButtonColor
Push-Pull
Out Center In Catalog Number �
N.O. -N.C.
OX
OO
XO Red 800H-FRXM6AP
Operator Position
Contact TypeMomentary Maintained Momentary
ButtonColor
Push-Pull
Out Center In Catalog Number �
N.O. -N.C.
OX
OO
XO Red 800H-FRXN6AP
Note: For NEMA 4/13 metal 30 mm operators see page 11-375.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-375� Prices – Consult Sales Office or price list
2 Position Push-Pull/Twist Release Units, Non-Illuminated
800 T – FX 1 APa b c d e
aOperator Type
Code Description �
T NEMA Type 4/13
H NEMA Type 4/4X
bOperator TypeNEMA Type 4/13
Code Description �
FX Push-Pull or Push-Pull Twist
NEMA Type 4/4X
Code Description �
FRX Push-Pull Twist Unit �
cHead Type
Code Description �
Blank Mushroom Head ��
J Jumbo Mushroom Head �
T Twist to Release
JT Jumbo Head w/Twist to Release
dColor Cap
Code Color �
Blank No Cap �
1 Green
2 Black
3 Orange
4 Gray
5 White
6 Red
7 Blue
9 Yellow
eContact Block(s)
Sealed SwitchOperator Position
Code
Out In
Description �
Blank — — No Contacts
D1P O X 1 N.O.
D2P X O 1 N.C.
AP OX
XO
1 N.O.1 N.C.
A4P XX
OO
2 N.C.
e (cont’d)Contact Block(s)
Stackable Sealed SwitchOperator Position
Code
Out In
Description �
D1Y O X 1 N.O.
D2Y X O 1 N.C.
A2Y OO
XX
2 N.O.
A4Y XX
OO
2 N.C.
AY OX
XO
1 N.O. - 1 N.C.
Logic ReedOperator Position
Code
Out In
Description �
D1R O X 1 N.O.
D2R X O 1 N.C.
AR OX
XO
1 N.O. - 1 N.C.
A2R OO
XX
2 N.O. �
A4R XX
OO
2 N.C.
Note: X=Closed/O=Open
3 Position Push-Pull Units, Non-Illuminated
800 T – FX M 1 APa b c d e f
aOperator Type
Code Description �
T NEMA Type 4/13
H NEMA Type 4/4X
bOperator TypeNEMA Type 4/13
Code Description �
FX Push-Pull Unit
NEMA Type 4/4X
Code Description �
FRX Push-Pull Unit
cHead Type
Code Description �
Blank Mushroom Head
J Jumbo Mushroom Head
dOperator Function
Operator Position
Code
Out Ctr. In
M Momentary Maintained Maintained
N Momentary Maintained Momentary
eColor Cap
Code Color �
Blank No Cap �
1 Green
2 Black
3 Orange
4 Gray
5 White
6 Red
7 Blue
9 Yellow
fContact Block(s)
Operator Position
Code
Out Ctr. In
Description �
Sealed Switch
AP OX
OO
XO
1 N.O. - 1 N.C.
BP
OXOX
OOOO
XOXO
2 N.O. - 2 N.C.
Stackable Sealed Switch
AY OX
OO
XO
1 N.O. - 1 N.C.
BY
OXOX
OOOO
XOXO
2 N.O. - 2 N.C.
Logic Reed
AR OX
OO
XO
1 N.O. - 1 N.C.
BR
OXOX
OOOO
XOXO
2 N.O. - 2 N.C.
Note: X=Closed/O=Open
� Must select Head Type “T” or “JT” to complete this catalog number. ��Not valid with “FRX” Operator Type.� Not valid with Head Type “T” or “JT”. � 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-376 � Prices – Consult Sales Office or price list
2 Position Push-Pull/ Twist Release Units, Illuminated
Note: X=Closed/O=Open
Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Illuminated 2 Position Push-Pull/TwistCatalog Number 800H-FRXTP16RAP
Operator Position
Lamp Type Volts ColorMaintained Maintained
Push-Pull/ Twist Release
Contacts Out In Catalog Number �
Full 120 AC Red N.O. - O X 800H-FRXTQ10RAP
Incan-
FullVoltage 24 AC/DC Red
N.O. N.C.
OX
XO 800H-FRXTQ24RAPIncan
descent Trans- 120 AC Red N.O. - O X 800H-FRXTP16RAPTransformer 240 AC Red
N.O. N.C.
OX
XO 800H-FRXTP26RAP
Full 120 AC Red N.O. - O X 800H-FRXTQH10RAP
LED
FullVoltage 24 AC/DC Red
N.O. N.C.
OX
XO 800H-FRXTQH24RAP
LEDTrans- 120 AC Red N.O. - O X 800H-FRXTPL16RAPTransformer 240 AC Red
N.O. N.C.
OX
XO 800H-FRXTPL26RAP
Note: For NEMA Type 4/13 metal 30 mm operators see page 11-377.
3 Position Push-Pull Units, Illuminated
Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Illuminated 3 Position Push-PullCatalog Number 800H-FRXMP16RAP
Operator Position Operator Position
Momentary MaintainedMaintained Momentary MomentaryMaintained
Contacts Out Center In Contacts Out Center In
Note: X=Closed/O=OpenN.C. -N.O.
XO
OO
OX
N.C. -N.O.
XO
OO
OX
Lamp Type Volts ColorPush-Pull Push-Pull
Lamp Type Volts ColorCatalog Number � Catalog Number �
IFull 120 AC Red 800H-FRXMQ10RAP 800H-FRXNQ10RAP
Incan-descent
FullVoltage 24 AC/DC Red 800H-FRXMQ24RAP 800H-FRXNQ24RAP
descentTrnsfmr. 120 AC Red 800H-FRXMP16RAP 800H-FRXNP16RAP
Full 120 AC Red 800H-FRXMQH10RAP 800H-FRXNQH10RAP
LEDFull
Voltage 24 AC/DC Red 800H-FRXMQH24RAP 800H-FRXNQH24RAPLED
Trnsfmr. 120 AC Red 800H-FRXMPL16RAP 800H-FRXNPL16RAP
Note: For NEMA Type 4/13 metal 30 mm operators see page 11-377.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-377� Prices – Consult Sales Office or price list
2 Position Push-Pull/Twist Release and 3 Position Push-Pull Units, Illuminated
800 T – FX T PL 16 R APa b c d e f g h
aNEMA Type
Code Description �
T NEMA Type 4/13
H NEMA Type 4/4X
bOperator TypeNEMA Type 4/13
Code Description �
FX Push-Pull/Push-PullTwist
NEMA Type 4/4X
Code Description �
FRX Push-Pull/Push-PullTwist
cHead Type
Code Description �
Blank Mushroom Head
J Jumbo MushroomHead �
dOperator Function
2-Position
Code Description �
Blank Push-Pull��
T Push-Pull/Twist �
3 Position
Code Operator Position
Code
Out Ctr. In
�
M � � �
N � � �
� Momentary �Maintained
eIllumination Options
Transformer
Code Description �
P StandardIncandescent
PF Flashing Lamp��
PH LED Cluster ��
PL LED ��
Full Voltage
Code Description �
Q StandardIncandescent
QF Flashing Lamp��
QH LED Cluster ��
QL LED ��
Resistor
Code Description �
Q Incandescent Lamp��
Neon
Code Description �
R Neon Lamp
Dual Input
Code Description �
D Dual Input Diode
DT Dual Input-Transformer Relay
fVoltage
Transformer
Code Description �
36 48V AC 50/60 Hz
16 120V AC 50/60 Hz
26 240V AC 50/60 Hz
76 277V AC 50/60 Hz
46 480V AC 50/60 Hz
56 600V AC 50/60 Hz
Full Voltage
Code Description �
06 6V AC/DC
12 12V AC/DC
24 24V AC/DC
10 120V AC/DC
20 240V AC/DC
Resistor
Code Description �
11 120V AC/DCResistor
Neon
Code Description �
10 120V AC/DC
20 240V AC/DC
Dual Input
Code Description �
16 120V AC 50/60 Hz
24 24V AC/DC50/60 Hz�
gColor Cap
Code Color �
X No Cap
A Amber
B Blue
C Clear
G Green
R Red
W White
hContact Blocks
Sealed Switch
Code Description �
D1P 1 N.O.
D2P 1 N.C.
AP 1 N.O. - 1 N.C.
Note: See Table 1 for Target description.
Stackable Sealed Switch
Code Description �
D1Y 1 N.O.
D2Y 1 N.C.
A2Y 2 N.O.
A4Y 2 N.C.
AY 1 N.O. - 1 N.C.
BY 2 N.O. - 2 N.C.
Logic Reed
Code Description �
D1R 1 N.O.
D2R 1 N.C.
A2R 2 N.O.
A4R 2 N.C.
AR 1 N.O. - 1 N.C.
BR 2 N.O. - 2 N.C.
Table 1. Target Selection2 Position 3 Position
h Code
Out In
ContactDescription
Out Ctr. In
h Code
D1P or D1R O X N.O. — — — —
D2P or D2R X O N.C. — — — —
AR or AP OX
XO
N.O.N.C.
OX
OO
XO
AR or AP
BR
OXOX
XOXO
N.O.N.C.N.O.N.C.
OXOX
OOOO
XOXO
BR
Note : X=Closed/O=Open.
� Not valid with Color Cap option “X” (No Cap). � Only valid for 3 position devices and NEMA Type 4/13 2 position units.� Not valid for 3 position devices. � Flashing lamps are only available in 6V Full Voltage units and all Transformer units.� LEDs are only available in red, green and amber; Color Cap must match LED color.� Use only with 6V AC, 24V AC/DC and 120V AC Full Voltage units, and all Transformer Units.� 120V Power Module drops voltage 10% to extend lamp life. Neon is only available in amber or clear. Dual input diode only.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-378 � Prices – Consult Sales Office or price list
2 Position Selector Switch Units, Non-IlluminatedLegend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Note: X=Closed/O=Open
Standard Knob OperatorCatalog Number 800H-HR2AP
Contac t TypeContact Location Operator
PositionOperator
TypeStandard Knob
Contact TypeSide Actuator
Color Contact
TypeM=MaintainedS=Spring Return Catalog Number �
M M 800H-HR2D1P
1 N.O. 1 White A O X S�M � 800H-HR4D1P1 N.O. 1 White A O X
M�S 800H-HR5D1P
M M 800H-HR2D2P
1 N.C. 1 White B X O S�M � 800H-HR4D2P1 N.C. 1 White B X O
M�S 800H-HR5D2P
1 N O 1 Whit A O XM M 800H-HR2AP
1 N.O. -1 N C
11
WhiteWhite
AB
OX
XO
S�M � 800H-HR4AP1 N.C. 1 White B X O
M�S 800H-HR5AP
O1 White A O X M M 800H-HR2BP
2 N.O. -2 N.C.
112
WhiteWhiteBlack
ABA
OXO
XOX
S�M � 800H-HR4BP2 N.C. 22
BlackBlack
AB
OX
XO M�S 800H-HR5BP
� Target tables are reversed from those shown.Note: For NEMA Type 4/13 metal 30 mm operators see page 11-379.
3 Position Selector Switch Units, Non-Illuminated
Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Note: X=Closed/O=Open
Standard Knob OperatorCatalog Number 800H-JR2AP
Contac t TypeContact Location Operator
PositionOperator
TypeStandard Knob
Contact TypeSide Actuator
Color Contact
TypeM=MaintainedS=Spring Return Catalog Number �
M M M 800H-JR2AP
1 N.O. - 1 White A X O O S�M M 800H-JR4AP1 N.O. 1 N.C.
11
WhiteWhite
AB
XO
OO
OX M M�S 800H-JR5AP
S�M�S 800H-JR91AP
1 White A X O OM M M 800H-JR2BP
2 N.O. -11
WhiteWhite
AB
XO
OO
OX S�M M 800H-JR4BP2 N.O.
2 N.C.122
WhiteBlackBlack
BAB
OXO
OOO
XOX
M M�S 800H-JR5BP2 Black B O O X
S�M�S 800H-JR91BP
Note: For NEMA Type 4/13 metal 30 mm operators see page 11-379.
(2 Position)
(3 Position)
Sealed Switch
Logic Reed
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-379� Prices – Consult Sales Office or price list
2 and 3 Position Selector Switch Units, Non-Illuminated
800 H–HR 2 D1Pa b c d e
800 T–J 5 KC1 HRa b c d1 e
aOperator Type
Code Description �
H-HR NEMA Type 4/4X 2 Position
H-JR NEMA Type 4/4X 3 Position
T-H � NEMA Type 4/13 2 Pos.
T-J � NEMA Type 4/13 3 Pos.
bKnob Insert Colors
Code Color �
Blank White knob insert orCylinder Lock Operator
A Red
B Green
C Blue
E Yellow
F Orange
X Packet of ColoredInserts �
cStandar d Knob Operators
Code Operator Function �
2 Maintained
4 Spring Return from Left
5 Spring Return from Right
91 � Spring Return from Both
dCam Option (2 Pos.)
Code Description �
Blank Std. Cam
KE8 KE8 Cam
Note: Associated cam targets shown inTable 1.
d1Cam Option (3 Pos.)
Code Description �
Blank KB7 Cam (Std.)
KA1 KA1 Cam
KA7 KA7 Cam
KC1 KC1 Cam
KC7 KC7 Cam
KD7 KD7 Cam
KE7 KE7 Cam
KQ1 KQ1 Cam
KQ7 KQ7 Cam
KR1 KR1 Cam
KR7 KR7 Cam
KT1 KT1 Cam
KT7 KT7 Cam
KU7 KU7 Cam
Note: Cam targets shown in Table 2.
eContact Blocks
Sealed SwitchCode Description �
Blank No contacts
D1P � 1 N.O.
D2P � 1 N.C.
AP1 N.O. - 1 N.C.
1-800T-XAP mountedon white side
BP
2 N.O. - 2 N.C.2-800T-XAP’s —1 on white side/1 on black side
Stackabl e Sealed Switch
Code Description �
D1Y � 1 N.O.
D2Y � 1 N.C.
AY1 N.O. - 1 N.C.
1-800T-XAY mountedon white side
BY
2 N.O. - 2 N.C.2-800T-XAY’s —1 on white side/1 on black side
HY
3 N.O. - 3 N.C.3-800T-XAY’s —2 on white side/1 on black side
CY
4 N.O. - 4 N.C.4-800T-XAY’s —2 on white side/2 on black side
e (cont’d)Contact Blocks
Logi c Reed
Code Description �
Blank No contacts
D1R � 1 N.O.
D2R � 1 N.C.
AR1 N.O. - 1 N.C.
1-800T-XAR mountedon white side
BR
2 N.O. - 2 N.C.2-800T-XAR’s —1 on white side/1 on black side
HR
3 N.O. - 3 N.C.3-800T-XAR’s —2 on white side/1 on black side
CR
4 N.O. - 4 N.C.4-800T-XAR’s —2 on white side/2 on black side
Note: Associated targets are shown inTable 1 for 2 position devices and Table 2for 3 position devices.
Table 1. 2 Position Cam and Contact Block Functionality Table Note: X=Closed/O=Open
C Cam Codes
Contact BlockSuffix Code
ContactBlock Side
Ckt
Std. Cam Maintained andSpring Returned from Right
Std. Cam Spring Returnedfrom Left KE8
Block Sides
D1P/D1R/D1Y White A O X X O X O
D2P/D2R/D2Y White B X O O X O X
AP/White
A O X X O X O
BP/BR/
AP/AR/AY White
B X O O X O X
HR/HY
BR/BY
BlackA O X X O O X
CR/HY
BYBlack
B X O O X X OCR/CY
WhiteA O X X O X O
WhiteB X O O X O X
BlackA O X X O O X
BlackB X O O X X O
Table 2. 3 Position Cam and Contact Block Functionality Table Note: X=Closed/O=Open
Con- C Cam CodesContac t Block
Suffix Code
Con-tact
BlockSid
Ckt
KB7(Std.) KA1 KA7 KC1 KC7 KD7 KE7 KQ1 KQ7 KR1 KR7 KT1 KT7 KU7
BlockSide s
AP / WhiteA X O O X O O O O X O O X X O O O O X X O O X O X X O X X O X X O X O O X X O O X O O
BP/BR
AP /AR/AY
WhiteB O O X O X O O X O O X O O X O O X O O X X O X O O X O O X O O X O X O O O O X O X O
HR/HY
BR/BY
BlackA X O O X O O O O X O O X X O O X O O O O X O O X X O O O O X X O O O O X X O O O O X
CR/
HR/HY
/BYBlack
B O O X O X O O X O X O O O O X O X O X X O O X O O X O X X O O X X X X O O X X X X OCR/CY
WhiteA X O O X O O O O X O O X X O O O O X X O O X O X X O X X O X X O X O O X X O O X O O
WhiteB O O X O X O O X O O X O O X O O X O O X X O X O O X O O X O O X O X O O O O X O X O
BlackA X O O X O O O O X O O X X O O X O O O O X O O X X O O O O X X O O O O X X O O O O X
BlackB O O X O X O O X O X O O O O X O X O X X O O X O O X O X X O O X X X X O O X X X X O
� Refer to Page 11-21 for additional knob and cylinder lock selections. � Refer to Page 11-23 for additional knob and cylinder lock selections.� Packet of colored inserts, one of each color except orange.�Option “91” only available on 3 position devices. �Available only on 2 position devices.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-380 � Prices – Consult Sales Office or price list
4 Position Selector Switch Units, Non-Illuminated ( Type 4/4X)Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Note: X=Closed/O=Open
Standard Knob OperatorCatalog Number 800H-NR2KF4PPXX
Contac t TypeContact Location Operator
PositionOperator
TypeStandard Knob
Contact TypeActuator
Color Contact
TypeM=MaintainedS=Spring Return Catalog Number �
WhiteWhit
AB
XO
OX
OO
OO
M M M M 800H-NR2KF4PPXXWhiteBlack
BA
OO
XO
OO
OX
S�M M M 800H-NR3KF4PPXXBlackBlack
AB
OO
OO
OX
XO M M M�S 800H-NR9KF4PPXX
2 N OWhiteWhit
AB
XO
XO
OX
OO
M M M M 800H-NR2KG4PPXX2 N.O. -2 N.C.
WhiteBlack
BA
OX
OO
XO
OO
S�M M M 800H-NR3KG4PPXX2 N.C. BlackBlack
AB
XO
OO
OO
OX M M M�S 800H-NR9KG4PPXX
WhiteWhit
AB
OX
OX
XO
XO
M M M M 800H-NR2KK4PPXXWhiteBlack
BA
XX
XO
OO
OX
S�M M M 800H-NR3KK4PPXXBlackBlack
AB
XO
OX
OX
XO M M M�S 800H-NR9KK4PPXX
4 Position Selector Switch Units, Non-Illuminated ( Type 4/13)
Legend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Note: X=Closed/O=Open
Standard Knob OperatorCatalog Number 800T-N2KF4BP
Contac t TypeContact Location Operator
PositionOperator
TypeStandard Knob
Contact TypeActuator
Color Contact
TypeM=MaintainedS=Spring Return Catalog Number �
— — — — — —M M M M 800T-N2KF4
No Contacts——
——
——
——
——
—— S�M M M 800T-N3KF4
— — — — — —M M M�S 800T-N9KF4
White A X O O O M M M M 800T-N2KF4BP2 N.O. -2 N.C.
WhiteWhiteBlack
ABA
XOO
OXO
OOO
OOX
S�M M M 800T-N3KF4BP2 N.C. BlackBlack
AB
OO
OO
OX
XO M M M�S 800T-N9KF4BP
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-381� Prices – Consult Sales Office or price list
4 Position Selector Switch Units, Non-Illuminated
800 T–N 2 KF4 BPa b c d e
800 H–NR 2 KF4 P P X Xa b c d e1 f1 g1 � h1 �a
Operator TypeCode Description �
T-N NEMA 4/13 4 Position
H-NR NEMA 4/4X4 Position
bKnob Insert Colors
Code Color �
Blank White
A Red
B Green
C Blue
E Yellow
F Orange
X Packet of ColorInserts �
Metal Wing Lever ColorsCode Color �
A Red
G Gray
cOperator Function and
Knob Type
Standard Knob
Code Operator Function �
2 Maintained
3 Spring Return fromPosition 1 to Position 2
9 Spring Return fromPosition 4 to Position 3
Knob Lever (Type 4/13 Only)
Code Operator Function �
17 Maintained
29 Spring Return fromPosition 1 to Position 2
30 Spring Return fromPosition 4 to Position 3
Metal Wing Lever (T ype 4/13 Only)
Code Operator Function �
11 Maintained
13 Spring Return fromPosition 1 to Position 2
14 Spring Return fromPosition 4 to Position 3
dCam Option
Code Description �
KF4 “F” Cam
KG4 “G” Cam
KK4 “K” Cam
KM4 “M” Cam
KP4 “P” Cam
eTraditional Contact Blocks
(Type 4/13) �Sealed Switch
Code Description �
BP 2 N.O. - 2 N.C.
Stackable Sealed SwitchCode Description �
BY 2 N.O. - 2 N.C.
HY 3 N.O. - 3 N.C.
CY 4 N.O. - 4 N.C.
Logic ReedCode Description �
BR 2 N.O. - 2 N.C.
HR 3 N.O. - 3 N.C.
CR 4 N.O. - 4 N.C.
Note: See Table 1 for Target table selection.
e1,f1,g1,h1Modular Contact Blocks
(Type 4/4X) �Sealed Switch (Modular Suffix)
Code Description �
R 1 N.O.
S 1 N.C.
P 1 N.O. - 1 N.C.
X No Contact
Stackable Sealed Switch(Modular Suffix)
Code Description �
5 1 N.O.
6 1 N.C.
8 2 N.O.
9 2 N.C.
7 1 N.O. - 1 N.C.
Logic Reed (Modular Suffix)Code Description �
V 1 N.O.
W 1 N.C.
Y � 2 N.O.
Z 2 N.C.
T 1 N.O. - 1 N.C.
Note: See Table 2 for Modular Target tableselection.
Table 1. Cam and Contact Block Functionality Table
Contact Block ContactCk
Cam CodesNote : W=White/B=Black. X=Closed/O=Open.
Contact BlockSuffix Code
ContactBlockSide
kt KF4 KG4 KK4 KM4 KP4 KN4Suffix Code Sidets
WhiteA X O O O X X O O O O X X X O O O O O O X O X O O
BR/BP/BY
WhiteB O X O O O O X O X X O O O X X O O X O O O O O X
CR/CYHR/HY
BR/BP/BY
BlackA O O O X X O O O X O O X O O O X O O X X O O X O
CR/CY BlackB O O X O O O O X O X X O O X O O X O O O X O O O
WhiteA X O O O X X O O O O X X X O O O O O O X O X O O
WhiteB O X O O O O X O X X O O O X X O O X O O O O O X
BlackA O O O X X O O O X O O X O O O X O O X X O O X O
BlackB O O X O O O O X O X X O O X O O X O O O X O O O
Table 2. Selector Switch Cam Targets Table 3. Contact Block Reduction Rules
Cam DescriptionNote : W=White/B=Black. Contact Block SubstitutionCam Descr ipt ionNote : W=White/B=Black.
X=Closed/O=Open. Sealed Switch �
Target KF4 KG4 KM4 KP4 KK4 Combination Substitute Code
Contact Block Side R+S P
W B W B W B W B W B Logic Reed �X O O O R, V, 5 — — R,V,5 R,V,5 — — S,W,6 — — Combination Substitute Code
O X O O S,W,6 — — — — S,W,6 S,W,6 — — — V+V Y
O O X O — S,W,6 S,W,6 — — — — — — — W+W Z
O O O X — R,V,5 — S,W,6 — R,V,5 R,V,5 — — — V+W T
X X O O — — R,V,5 — — — — — S,W,6 — Stackable Sealed Switch �O X X O — — — — S,W,6 — — — — S,W,6 Combination Substitute Code
O O X X — — — — — — — R,V,5 R,V,5 — 5 + 6 7
X O O X — — — — — — — — — R,V,5 5 + 5 8
6 + 6 9
� Positions “g 1” and “h 1” must be filled with an “X” for sealed switch contact blocks.� Packet of color inserts includes one of each color except orange. � See Table 1. � See Table 2.� 800T-XA2R contact blocks cannot be stacked upon, but they can stack on other contact blocks.���Contacts must be on the same side to substitute.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-382 � Prices – Consult Sales Office or price list
Pilot Light UnitsLegend Plates – Pages 11-46, 11-91Accessories – Page 11-385Dimensions – Page 11-389
Transformer Type Pilot LightCatalog Number 800H-PR16R
Push-To-Test Pilot LightCatalog Number 800H-PRT16RAP
Lamp Type Volts ColorPilot Light Push- To-Test Dual Input
Lamp Type Volts ColorCatalog Number � Catalog Number � Catalog Number �
Full120 AC
RedGreenAmber
800H-QR10R800H-QR10G800H-QR10A
800H-QRT10RAP800H-QRT10GAP800H-QRT10AAP
800H-PRD16R800H-PRD16G800H-PRD16A
Incan-descent
FullVoltage �
24 AC/DCRed
GreenAmber
800H-QR24R800H-QR24G800H-QR24A
800H-QRT24RAP800H-QRT24GAP800H-QRT24AAP
800H-PRD24R800H-PRD24G800H-PRD24A
Trans-former � 120 AC
RedGreenAmber
800H-PR16R800H-PR16G800H-PR16A
800H-PRT16RAP800H-PRT16GAP800H-PRT16AAP
800H-PRDT16R800H-PRDT16G800H-PRDT16A
Full120 AC
RedGreenAmber
800H-QRH10R800H-QRH10G800H-QRH10A
800H-QRTH10RAP800H-QRTH10GAP800H-QRTH10AAP
800H-QRDL16R800H-QRDL16G800H-QRDL16A
LED �
FullVoltage
24 AC/DCRed
GreenAmber
800H-QRH24R800H-QRH24G800H-QRH24A
800H-QRTH24RAP800H-QRTH24GAP800H-QRTH24AAP
800H-QRDL24R800H-QRDL24G800H-QRDL24A
Trans-former 120 AC
RedGreenAmber
800H-PRL16R800H-PRL16G800H-PRL16A
800H-PRTL16RAP800H-PRTL16GAP800H-PRTL16AAP
800H-PRDTL16R800H-PRDTL16G800H-PRDTL16A
� Full Voltage Dual Input units are Diode Type. � Transformer Dual Input units are Transformer-Relay Type.
� For High Visibility 28 chip LED, change the letter “L” to “H” .
Typical Pilot Light Wiring DiagramsSee applicable Codes and Laws
�
Push- To-Test Pilot Light Device Schematic Dual Input Diode Pilot Light Device Schematic
Dual Input Pilot LightTypical Application Wiring Diagram
Dual Input Pilot LightTransformer Type Device Schematic
�� �
�� ��������
��� �����
������
���� ����� �� ��
���
���
���
�� �����
���
���
���
���
���
���
���
�������
��� �����
������
��� ��
������
����
����
(Pilot Light)
(Push-to-Test)
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-383� Prices – Consult Sales Office or price list
Pilot Light Units
800 H – QR L 24 Ra b c d e f
800 T – P T 16 R APa b c d e f g
aOperator Type
Code Description �
T NEMA Type 4/13
H NEMA Type 4/4X
bPower Module T ype
NEMA Type 4/13
Code Description �
P Transformer(or Dual Input)
Q Full Voltage (or Resistor)
R Neon �
NEMA Type 4/4X
Code Description �
PR Transformer
QR Full Voltage (orResistor)
RR Neon �
cLamp Test Options
Code Description �
Blank No Test Option
T Push-to-Test
D Dual Input-Diode
DT Dual InputTransformer Relay
Note: Push-to-Test Pilot Light can besupplied with a factory jumpered800T-XAP or 800T-XAR, 1 N.O. - 1 N.C.Contact Block.
dIllumination Options
Transformer
Code Description �
Blank Standard Pilot Light
F Flashing Lamp �
H LED Cluster �
L LED �
Full Voltage
Code Description �
Blank Standard Pilot Light
F Flashing Lamp �
H LED Cluster ��
L LED ��
Resistor
Code Description �
Blank No Options
Neon
Code Description �
Blank No Options
eVoltage
Transformer
Code Description �
36 48V AC 50/60 Hz
16 120V AC 50/60 Hz
26 240V AC 50/60 Hz
76 277V AC 50/60 Hz
46 480V AC 50/60 Hz
56 600V AC 50/60 Hz
Full Voltage
Code Description �
06 6V AC/DC
12 12V AC/DC
24 24V AC/DC
10 120V AC/DC
20 240V AC/DC
Resistor
Code Description �
11 120V AC/DCResistor
Neon
Code Description �
10 120V AC/DC
20 240V AC/DC
Dual Input
Code Description �
16 120V AC 50/60 Hz
24 24V AC/DC50/60 Hz �
fLens Color
Plastic
Code Color �
Blank No Lens
A Amber
B Blue
C Clear
G Green
R Red
W White
Glass �
Code Color �
D Amber
E Blue
F Clear
H Green
J Red
K White
gContact Block �
Sealed Switch
Code Description �
AP 1 N.O. - 1 N.C.
Stackable Sealed Switch
Code Description �
AY 1 N.O. - 1 N.C.
Logic Reed
Code Description �
AR 1 N.O. - 1 N.C.
� Neon is only available in amber or clear.� Flashing lamps only available in 6V Full Voltage units and all Transformer units.� LEDs are only available in red, green and amber; lens color must match LED color.� Use only with 6V AC, 24V AC/DC and 120V AC Full Voltage units.� Dual Input Diode only.� Glass lens available on 800T Pilot Lights only. Not available on Push-To-Test or Type 4/4X units.� Push-to-Test Units only.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-384 � Prices – Consult Sales Office or price list
Custom Built StationsDescriptionThe price tables on Pages 11-366 and11-367 list the most commonly usedPush Button Stations. Stations not listedin the price tables may be ordered ascustom built stations.
PricingThe price for a custom built station is theprice of the enclosure, plus the price ofthe units and accessories to be installedin the enclosure.
Catalog NumberThe catalog number used to identifycustom built Bulletin 800R Push ButtonStations, which are built at the factory,will be catalog numbers listed for theenclosure only, except letter “W” will besubstituted for the letter “Z” and with astation serial number.
Ordering InformationThe following information is requiredwhen ordering custom built push buttonstations.1. Catalog number of enclosure.2. Catalog number of control units.3. Legend plate catalog number and/or
marking for each unit.4. Specify vertical or horizontal
mounting.5. Specify desired operator mounting
sequence. Inclusion of a sketch isrecommended. If no information isgiven, best judgement will be used.
Enclosures Only
Stainless SteelCatalog Number 800R-2HZ4
ROSITE Glass PolyesterCatalog Number 800R-2HZ4R
Die CastCatalog Number 800R-2TZ
Units�Die Cast
(NEMA Type 4/13)Stainless Steel(NEMA Type 4)
ROSITE Glass Polyester(NEMA Type 4/4X)Units�
Catalog Number � Catalog Number � Catalog Number �
1 800R-1TZ 800R-1HZ4 800R-1HZ4R
2 800R-2TZ 800R-2HZ4 800R-2HZ4R
3 800R-3TZ 800R-3HZ4 800R-3HZ4R
4 800R-4TZ 800R-4HZ4 800R-4HZ4R
5 — 800R-5HZ4 800R-5HZ4R
6 800R-6TZ 800R-6HZ4 800R-6HZ4R
� Number of units that can be mounted in enclosure.
Note: Enclosure and conduit dimensions are detailed on Page 11-389.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-385� Prices – Consult Sales Office or price list
Modifications and AccessoriesContact BlocksPackaged in kit form for field installation. All necessary mounting hardware is provided with each contact block kit. Contactratings are listed on Page 11-365. Sealed switch contact blocks are limited to two blocks per unit maximum. Logic Reed blocksand Stackable Sealed Switch blocks may be configured with four blocks per unit (two blocks on each side).
Logic Reed Block Sealed Switch Block Stackable Sealed Switch Block
N mber of ContactsLogic Reed Block � Sealed Switch Block � Stackable Sealed Switch Block �
Number of ContactsCatalog Number � Catalog Number � Catalog Number �
1 N.O. 800T-XD1R 800T-XD1P 800T-XD1Y
1 N.C. 800T-XD2R 800T-XD2P 800T-XD2Y
1 N.O. - 1 N.C. 800T-XAR 800T-XAP 800T-XAY
2 N.O. 800T-XA2R — 800T-XA2Y
2 N.C. 800T-XA4R — 800T-XA4Y
� A Bulletin 800T or 800H operator using Sealed Switch, Stackable Sealed Switch, and Logic Reed contact blocks and installed in a suitableenclosure are U.L. Listed as suitable for use in Class I, Division 2 Hazardous locations.
Approximate DimensionsDimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
���������������
�����������
���� �� ���
�����������
��� �����
������������
����������
Logic Reed Contact Block11/8 (28.6) Deep
Sealed Switch Block2 (50.8) Deep
������ �������
Stackable Sealed Switch Block1.58 (40.1) Deep
������������������
���������������������������
�����
����������������
����������������
�������
� Dimension shown is for Push Buttons. Selector Switch dimension is 129/32 (48.4). Cylinder Lock Selector Switch is 21/32 (51.6).� Dimension shown is for Push Buttons. Selector Switch dimension is 223/32 (69.1). Cylinder Lock Selector Switch is 227/32 (72.2).
For Information on Additional Accessories – Refer to Bulletin 800T, Bulletin 800H NEMA Type 4X and Bulletin 800H NEMA Type 7 & 9 Sections.
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-386 � Prices – Consult Sales Office or price list
Conversion TablesOrdering InformationTo order Division 2 rated HazardousLocation Push Buttons:1. Refer to the 800T/800H section to
determine the appropriate operatorfor your application.
2. Match the 800T/800H operator typewith the corresponding table in the800R section.
3. Using the Catalog Number of the800T/800H operator determined inStep 1, substitute the StandardContact Block Suffix Code with therequired Sealed Switch or LogicReed Contact Block Suffix Code.
Ordering ExampleTo convert an 800T Momentary ContactNon-Illuminated Push Button to aMomentary Contact Non-IlluminatedPush Button with a Sealed SwitchContact Block, refer to the 800T section,Page 11-8. Determine theappropriate operator type and CatalogNumber for your application. When youhave determined the operator type andCatalog Number, refer to thecorresponding table in the 800R section,Page 11-387. Substitute the StandardContact Block Suffix Code with theSealed Switch Contact Block SuffixCode. Example: Catalog Number800T-A1A becomes 800T-A1AP.
Momentary Push Buttons, Non-Illuminated and IlluminatedIncludes the following operators: Momentary Contact/Cylinder Lock/Padlocking Mushroom Head/Wobble Stick
ContactArrangement
Sealed Switch ContactBlock
Stackable SealedSwitch Contact Block
Logic Reed ContactBlock
ArrangementSuffix Code � Suffix Code � Suffix Code �
1 N.O. D1P D1Y D1R
1 N.C. D2P D2Y D2R
2 N.O. A2P � A2Y A2R
2 N.C. A4P � A4Y A4R
1 N.O. - 1 N.C. AP AY AR
2 N.O. - 2 N.C. BP � BY BR
3 N.O. - 3 N.C. — HY � HR �
4 N.O. - 4 N.C. — CY � CR �
��Not valid with Illuminated Push Buttons.
Mechanicall y Interlocked, Maintained Push Button Units
ContactArrangement
Sealed Switch ContactBlock
Stackable SealedSwitch Contact Block
Logic Reed ContactBlock
ArrangementSuffix Code � Suffix Code � Suffix Code �
1 N.O. D1P D1Y D1R
1 N.C. D2P D2Y D2R
2 N.O. — A2Y A2R
2 N.C. — A4Y A4R
1 N.O. - 1 N.C. AP AY AR
2 N.O. - 2 N.C. BP BY BR
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-387� Prices – Consult Sales Office or price list
Conversion Tables – Cont’d2-Position Push-Pull and Push-Pull Twist/Release Units Non-Illuminated and Illuminated
OperatorPosition
Contact
Sealed SwitchContact Block
Stackable SealedSwitch Contact
Block
Logic ReedContact Block
Out In
ContactArrangement
SuffixCode �
SuffixCode �
SuffixCode �
O O 1 N.O. D1P D1Y D1R
X O 1 N.C.L.B. D2P � — D2R �
OX
XO 1 N.O. - 1 N.C.L.B AP � — AR �
OO
XX 2 N.O. A2P A2Y A2R
XX
OO 2 N.C.L.B. A4P �� — A4R �
��Standard N.C. contacts are substituted for N.C.L.B. contacts.
��Only valid with Non-Illuminated Operators.
3-Position Push-Pull Units Non-Illuminated and Illuminated
Operator Position
Contact
Sealed SwitchContact Block
Stackable SealedSwitch Contact
Block
Logic ReedContact Block
Out Center In
ContactArrangement
SuffixCode �
SuffixCode �
SuffixCode �
OX
OO
XO 1 N.O. - 1 N.C. AP AY AR
2-, 3- and 4-Position Selector Switch Units, Non-Illuminated (Excluding Bulletin 800H NEMA Type 7 & 9)
ContactArrangement
Sealed Switch ContactBlock
Stackable SealedSwitch Contact Block
Logic Reed ContactBlock
ArrangementSuffix Code � Suffix Code � Suffix Code �
1 N.O. D1P D1Y D1R
1 N.C. D2P D2Y D2R
2 N.O. RRXX A2Y A2R
2 N.C. SSXX A4Y A4R
1 N.O. - 1 N.C. AP AY AR
2 N.O. - 2 N.C. BP BY BR
3 N.O. - 3 N.C. — HY HR
4 N.O. - 4 N.C. — CY CR
2 N.O. - 2 N.C. PPXX 77XX TTXX
4 N.O. - 4 N.C. — 7777 TVXX
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-388 � Prices – Consult Sales Office or price list
Conversion Tables – Cont’d
1-2-3-4 Way Toggle Switches (800T only)
ContactArrangement
Sealed Switch ContactBlock �
Stackable SealedSwitch Contact Block �
Logic Reed ContactBlock
ArrangementSuffix Code � Suffix Code � Suffix Code �
1 N.O. R 5 V
1 N.C. S 6 W
1 N.O.E.M. — — —
1 N.C.L.B. — — —
1 N.O. - 1 N.C. P 7 T
1 N.C.L.B. - 1 N.O. — — —
1 N.C.L.B. - 1 N.C. — — —
2 N.O. — 8 Y
2 N.C. — 9 Z
� For sealed switch contacts, the third and fourth positions of the configurated contact blocks must be filled withthe letter “X” (no contact block). Example: Catalog Number 800T-T2H2PPXX incorporates an “X” in the thirdand fourth positions.
Push-To-Test Pilot Light Units
Contact ArrangementSealed Switch Contact
BlockStackable Sealed
Switch Contact BlockContact ArrangementSuffix Code � Suffix Code �
Blank (1 N.O. - 1 N.C.) AP AY
��Selector Switch is 15/32 (29.4) maximum; Pilot Light is 17/32 (31).
� Selector Switch is 13/32 (27.8) maximum; Pilot Light is 15/32 (29.4) maximum.
�'����� ���
�'�������
��
�'� ����
������� �����%�
�
�'�����������
�������
���
�'���������� �
�������������%��
�
�'�������� �
�'����� �� �
�'�����������
�������
�
�
��������%���������
������� ���
� �� ���������
�'���������������
�'��������
�'����������
����������
����������
�%#� ��������� �&
�'����������
�'����������
�'����������������
�'���������
�'��������
������
������"����
����������
�'�������� ��
�'���������������
�� ��$��!��� �
�
�
NEMA Type 4Stainless Steel
Watertight/Dust- TightEnclosure
NEMA Type 4XROSITE Glass Polyester
Watertight/Corrosion ResistantEnclosure
NEMA Type 4/13Watertight/Oiltight
Cast AluminumEnclosure
Operator Extension in Front of Panel �
� Selector Switch is 17/32 (30.9) maximum; Pilot Light is 19/32 (32.5).
NEMA Type 4/4XBooted
Flush & ExtendedHead Push Button
NEMA Type4/4X
Pilot Light
NEMA Type 4/13and Type 4/4X
BootlessFlush & ExtendedHead Push Button
NEMA Type4/13
Pilot Light
NEMA Type 4/13and 4 & 4X
Standard KnobSelector Switches
Mounting Instructions(For Panel Mounting)
� Minimum vertical spacing dimension for Jumbo Legend Plate is 215/32 (62.7).
��See Pages 11-50 thru 11-53 for additional NEMA Type 4/13 outlines and Pages 11-95 thru 11-98 for additional NEMA
Bulletin 800R
NEMA Style Push Buttons Hermetically Sealed For Division 2NEMA Type 4/13 and 4/4X For Hazardous Locations
11-389
Approximate Dimensions and Shipping WeightsDimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
DimensionNumber of Units
Dimension1 2 3 4 5 6
NEMA Type 4
A 55/32 (135) 7 (178) 827/32 (225) 1011/16 (271) 1217/32 (318) 143/8 (360)
B 613/32 (163) 81/4 (210) 101/8 (257) 1131/32 (304) 141/32 (359) 157/8 (403)
Pipe Tap Size 3/4 1
NEMA Type 4X
A 41/2 (114) 41/2 (114) 61/4 (159) 8 (203) 121/8 (308) 121/8 (308)
B 71/32 (181) 71/32 (181) 823/32 (221) 1021/32 (271) 147/8 (378) 147/8 (378)
C 57/8 (149) 57/8 (149) 79/16 (192) 91/2 (241) 131/2 (343) 131/2 (343)
Pipe Tap Size 3/4 1
NEMA Type 4/13
A 23/4 (69.8) 41/2 (114) 61/4 (159) 8 (203) — 121/8 (308)
B 43/16 (106) 57/8 (149) 79/16 (192) 91/2 (241) — 131/2 (343)
ConduitOpening
3/4”-14 N.P.T. —1”-111/2N.P.T.