8
04 05 19/WIR BuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS CATALOG INNOVATION IN MASONRY CONSTRUCTION ® INNOVATION IN MASONRY CONSTRUCTION

BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

Embed Size (px)

Citation preview

Page 1: BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

04 05 19/WIRBuyLine 0452

SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS

2009

PRODUCTS

CATALOG

I N N O VAT I O N I N M A S O N R Y C O N S T R U C T I O N®

I N N O VAT I O N I N M A S O N R Y C O N S T R U C T I O N

0452_01:0452_09 9/16/08 4:40 PM Page 1

Page 2: BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

2

ManufacturerWIRE-BOND® offers over 30 years experience in the manufacture and fabrication of wire intomasonry wall reinforcing materials and ties. Our large manu-facturing capacity and in-stock inventory insure you the verybest in service. We pledge complete customer satisfaction.

Our in-house hot dip and strand galvanizing facilities offertotal product control, insure optimum quality, and quick turn-around on orders.

Product LineWe produce continuous systems of masonry wall reinforcingincluding truss and ladder designs. Variations are available to these standard designs to meet specific wall conditions andare illustrated in this catalog.

WIRE-BOND® offers unit ties designed to tie masonry wallsto steel, concrete, and masonry. They are manufactured invarious finishes and sizes to meet specific conditions asshown.

Tensile StrengthYield PointReduction of Area

80,000 PSI70,000 PSI minimum30 %

StandardMediumHeavy DutyExtra Heavy Duty

9 Gauge (.148 in)8 Gauge (.162 in)3/16" (.187 in)3/16" (.187 in)

9 Gauge9 Gauge9 Gauge3/16"

All wire conforms to ASTM A951-96. This specification covers themanufacturing guidelines and minimum weld strength,required formasonry joint reinforcement.

ACI 530 Code recommends mill galvanized ASTM A641 (0.1 oz/ft2)(0.031 kg/m2) for joint reinforcement in interior walls. For cavity andexterior walls hot dipped galvanized ASTM A153 (1.5 oz/ft2) (458 g/m2) is recommended for joint reinforcement, wire ties, andanchors. Hot dipped is also recommended for interior wallsexposed to a mean relative humidity exceeding 75%. Class I ASTMA641 (0.4 oz/ft2) and Class III (0.8 oz/ft2) are no longer recommendedby ACI 530 for interior walls.

Epoxy coating is not recommended as a protective coating for jointreinforcement, anchors and ties. Manufacturer recommendsStainless Steel Type 304 for maximum corrosion protection.

PlainMill GalvanizedHot Dipped Galvanized After FabricationStainless Steel

UncoatedZinc Coated (0.10 oz per sq ft)Zinc Coated ASTM A153 Class B2 (1.50 oz per sq ft)ASTM 580 Type 304

Side Rods Cross Rods

ASTM A 82 Wire Requirements (for cold drawn steel wire)

Wire Gauges

QQ-W-461 f Finish 1 Wire Requirements (for hard tempered wire)

Finishes Description

Manufacturer’s RecommendationInterior WallsInterior walls, which are non-load bearing, should utilizestandard weight reinforcing with a mill galvanized finish.

Exterior WallsExterior load bearing walls need a three or four-wire systemwith two longitudinal wires in the block and one or two longitudinal wires in the brick as conditions dictate. We rec-ommend hot dipped galvanized after fabrication, ASTM A153 Class B2, where complete protection from corrosion isrequired.

Uneven coursing, or conditions where block is laid first andbrick later, should use the adjustable tab or hook-and-eye sys-tem. An additional advantage to adjustable reinforcing is toprovide a mechanical tie to restrain insulation in a partiallyfilled masonry cavity wall.

Special MaterialOur manufacturing capabilities allow us to make a wide vari-ety of products, some of which are not shown in our catalog.Please contact us for specific advice and availability of anyitem you may require for masonry walls.

Visit Our WebsiteVisit www.wirebond.com to see our complete catalog of masonryjoint reinforcment products and accessories. The WIRE-BOND®

website also provides product submittals for the majority of ourproducts, along with "Building Code Requirements For MasonryConstruction" from the ACI530 Code as well as MSDS sheets. Inorder to download the product submittals, you must have AdobeAcrobat Reader software installed on your computer. A free down-load of the software is available at the Product Submittals title page.

Code Compliances

WIRE-BOND®’s products are manufactured in compliancewith the following building codes:

• SBCC - Southern Building Code Congress

• BOCA - Building Officials Congress in America

• ICBO - International Conference of Building Officials

• ACI/ASCE 530 Code - Building Code Requirements

for Masonry structures

• CSA A370-94 - Connectors for Masonry

WIRE-BOND • 800-849-6722www.wirebond.com

®

0452_02:0452_09 9/16/08 4:43 PM Page 2

Page 3: BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

04 05 19/WIRBuyLine 0452

Series 900 — Level Eye Truss Hook and Eye 16" on Center

TrussLadder

Single Wythe — Ladder 2 Wire System (Series 200)

Series 600 — Level Adjustable Tab Ladder 16" on Center

Series 800 — Level Eye Ladder Hook and Eye 16" on Center

Level Adjustable Tab (U.S. Pat. #6,735,915) (U.S. Pat.#7,152,382B2)Also available for both ladder and truss, Level Adjustabletab has in-line tabs welded to side rods of 9-gauge or 3/16”wire. Profile of welded assembly does not exceed 3/16”height. Exceeds requirement of ASTM951. New design oftab meets ACI530 code. Tab lengths extend beyond blockto accommodate varying widths of insulation. Tabs andwall ties are 3/16” diameter wire.

Single Wythe — Truss 2 Wire System (Series 300)

Series 700 — Level Adjustable Tab Truss 16" on Center

Level Eye Adjustable System (U.S. Pat. #6,735,915) (U.S. Pat.#7,152,382B2)Available for both ladder and truss, Level Eye has in-lineeyelets welded to side rods of 3/16" or 9-gauge wire.Profile of welded assembly does not exceed 3/16" height.Exceeds requirements of ASTM951. Lollipop design ofeyelets provides less than 1/16" tolerance and meetsACI530 Code. Eyelet lengths extend beyond block toaccommodate varying widths of insulation. Hooks andeyelets are 3/16" diameter wire. Eyelets undergo a five-step quality control process.

Level Adjustable Tab Truss

Level Eye Ladder Level Eye Truss

Level Adjustable Tab Ladder

3WIRE-BOND • 800-849-6722 www.wirebond.com

®

0452_03:0452_09 9/16/08 5:58 PM Page 3

Page 4: BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

Type III-X AnchorSimilar to Type III. The prongs allow positive contact withsteel stud backup. Prongs are available in 1/2", 5/8", 1", 1 1/2",2", and 2 1/2".

Available in 14 ga. and 12 ga. (plate). Finishes: mill galvanized,hot dip galvanized, stainless steel.

HCL-711 AnchorAn adaptation of the popular RJ-711, HCL-711 has threenew pointed prongs which pierce wallboard and abut to back-up (steel stud). 14-gauge prongs allow little or no compressiblemovement where wallboard may deteriorate.

WIRE-BOND ClipThe WIRE-BOND clip conforms to requirements ofUniform Building Codes for seismic zones. Continuouswire is embedded in mortar joint, secured to tie anchorwhich is fastened to support structure.

RJ-711 Adjustable Veneer AnchorPlate is available in either 14 ga. or 12 ga.; wire is 3/16"diameter. Available in mill galvanized, hot dip galvanizedand stainless steel. Hook lengths are 3-1/4", 4-1/4" and 5-1/4".Hook adjustments are maximum of 1-1/4" up or down. Alsoavailable for insulated walls. Test data provided uponrequest.

Tying Masonry to Steel

2401 (Plate)2403 (Hook)

Sure-Tie®

Type III AnchorIndividual anchors that are fastened to metal studs.

Type III available in 14 ga. and 12 ga. (plate). Finishes: mill gal-vanized, hot dip galvanized, stainless steel.

Wall BoardSteel Stud

Anchor

Anchorseal

Sure-Tie® installs quickly and easily on steel stud/’brick veneerapplications. #12-24 tapping thread 1” in length pierces 1/2”and 5/8” wallboard and various sizes of insulation. Climasealcoating proides superior corrosion resistance. Triangularadjustable ties are 3/16” in diameter and are available in hot-dipped and stainless steel finishes.

4 WIRE-BOND • 800-849-6722

1004-X

1004

www.wirebond.com

®

Steel Stud

Wall Board

InsulationAnchorseal

Anchor

2401 (Plate)2402 (Hook)

0452_04:0452_09 9/16/08 5:22 PM Page 4

Page 5: BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

CoreLock (Pat Pending)New rebar positioner is “seated” 1-1/4” into core of CMU.Diagonal placement in block insures rebar is automatical-ly centered and prevents any possible movement of posi-tioner during rebar installation. Simple, one-piece, no-weld design. Does not interfere with installation of wiremasonry joint reinforcement.

Special Products

Plumb-Rite is a T-shaped PVC product that assists in keep-ing vertical joints in precise alignment where control jointsand expansion joints are used in a masonry wall. Plumb-Rite is rigid enough to keep a 3/8" vertical joint consistentlystraight. It is flexible enough -- with a special slotted stem --to allow for expansion of the brick.

Plumb-Rite may be attached to wood, steel, and block back-ups with either nails, screws or mastic. When insulation isused in the cavity, foam board adhesive is simply applied tothe back of the Plumb-Rite and adhered to the insulation.

Plumb-Rite U.S. Pat. #6,293,066B1

Accessory Items

Mortar Suspension

Mortar Net™ Drainage System U.S. Pat. #5,230,189Mortar Net™ is placed on top of the flashing inside thecavity where it catches and suspends mortar droppingsabove the level of weep holes and flashing. Dovetailshape prevents mortar from forming a continuous dam.Shape of the material, in combination with 90% open plas-tic mesh configuration, allows water and air to moverapidly and easily through material to the weeps.

Cavity should be no more than 1/4" wider than 1.0" and2.0" thick material and 0.4 thick material should touchboth the outer and inner wall, insulation, or filler used toadjust the cavity size.

Weep Vents

Cell VentCell vent consists of many small, adjacent passageways bonded together in one unit. Cellular composi-tion provides easy drainage for moisture along the full height of the head joint. 3/8"W x2-1/2"D x 3-3/8"L. 100 per box. Jumbo sizes (3/8”W x 3-1/2”D x 3-3/8”L) and colors available.

3601

Plastic Weepholes3/8" O.D. x 1/4" I.D. x 4". 200 per box.

Screen 3600FWick & Screen 3600B

5

04 05 19/WIRBuyLine 0452

WIRE-BOND • 800-849-6722 www.wirebond.com

®

0452_05:0452_09 9/16/08 4:47 PM Page 5

Page 6: BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

Aqua-Flash 500®

MaterialsA composite sheet type waterproofing membrane consistingof 8 mils of high density cross laminated polyethylene bond-ed to 32 mils of rubberized asphalt for a total thickness of40 mils. Available in 12", 16", 18", 24" and 36" widths.Standard length is 50 linear feet.

AQUA-MASTIC® AND AQUA-PRIMER®

AQUA-MASTIC and AQUA-PRIMER are available in 5gallon pails. AQUA-MASTIC is also available in 32 oz.tubes.

Special RequirementsAll materials specified shall be delivered to the jobsite inapproved manufacturer’s sealed containers bearing manu-facturer’s name and material identification.

Applications• Thru-wall flashing• Concealed flashing• Foundation sill flashing• Base flashing• Spandrel flashing• Head and sill flashing• Parapet flashing

FeaturesA composite flashing which:

• Is self-sealing• Has excellent puncture resistance• Is self-healing since the adhesive system

will elongate and recover if somewhat damaged

• Needs no reglet when adhering membrane to vertical substrate

Aqua-Flash 500

4120

Flashing and Accessories

Copper Fabric FlashingHighest quality laminated copper flashing on the markettoday. Available in 2, 3, 5, or 7 oz. per square foot. Two lay-ers of dense glass fabric and special blended asphalt arelaminated to copper core to produce greater tensile strengthand improved puncture resistance. Composition of copper,glass fabric and asphalt will ensure a permanent bond in themortar joint and protection from moisture. Rolls are 12",16", 18", 24", and 36" wide x 25' long.

Base Flashing

CopperLaminatedThru-WallFlashing

Weep Hole

Note: “Flashing mustextend beyond the face ofthe wall or cut flush”,Brick Institute of America,Tech Note #7

6 WIRE-BOND • 800-849-6722

Drip Edge Flashing,when used withFiberweb products orAqua Flash 500, cre-ates an effective mois-ture barrier. Type 304stainless steel, 26gauge. 1 1/2" and 3"wide by 8' sections.Packaged 50 per box.

4156Drip Edge Flashing

Termination Bar 4200

Attaches flashingto back-up wall.Available in alu-minum and stain-less steel finish.Flat aluminum1/8" x 1" wide by10' sections with3/8" slotted holes,8" O.C. 50 pieces per tube. Flat stainless bar 1/8" x 1" wideby 10' sections: holes 5/16", 16"O.C.

www.wirebond.com

®

0452_06:0452_09 9/16/08 4:48 PM Page 6

Page 7: BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

• We work from your architectural drawings to cut and bend to your exact specifications.

• Sizes and shapes shown here are just a few of the designs we can make.

• Available in hot dip galvanized and high grade 304 stainless steel. (Stainless steel shown at left).

• Our specialized manufacturing facilities insure quick turn-around to meet your construction deadlines

Stone Anchors

Control JointsControl JointsExtruded from a specially formulated PVC compound with80 durometer hardness conforming to ASTM D 2240. It is designed for use in solid or cavity masonry wall con-struction at pilasters, columns, intersections or other joints. In long walls, control joints at 30-foot intervals are recom-mended to provide resilient resistance to cracking understress of expansion and contraction. A rubber control jointis also available in all sizes except 2903. Conforms toASTM D 2000 2 AA 805 with a durometer hardness of 80.

PVC CONTROL JOINTProperty Nominal Value

Tensile-Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 psiSpecific Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..1.29Ultimate Elongation-Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420%Water Absorption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +0.141%Brittle Point (calculated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-300 FHardness-Shore A/10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

RUBBER CONTROL JOINTProperty Nominal Value

Tensile-Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2425 psiModulus @ 100 elongation, psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1100Specific Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.32Ultimate Elongation-Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375%Water Absorption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .per ASTM D 570 Brittle Point (calculated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -100 FHardness-Shore A/10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76

Horizontal Expansion Joint1/4" x 2-3/4" x 50' adhesive on one side; compression up to50%; manufactured of closed cell neoprene conforming toASTM D 1056, RE41. Packed 500 feet per box.

3300 Horizontal

3300 Vertical

Vertical Expansion Joint3/8" x 3" x 50' with no adhesive; compression up to 50%;manufactured of closed cell neoprene conforming to ASTMD 1056, RE41. Packed 500 feet per box.

7

04 05 19/WIRBuyLine 0452

WIRE-BOND • 800-849-6722 www.wirebond.com

®

0452_07:0452_09 9/16/08 4:48 PM Page 7

Page 8: BuyLine 0452 - Sweetssweets.construction.com/swts_content_files/576/0452_040519-WIR_09.pdfBuyLine 0452 SERVING THE MASONRY CONSTRUCTION INDUSTRY FOR OVER THIRTY YEARS 2009 PRODUCTS

©Copyright 2009 WIRE-BOND® All rights reserved. All contents current at time of publication. WIRE-BOND reserves the right to change availability of any item in this catalog, including its design,

construction, and/or materials.

A more extensive printed catalog or CD-Rom of our complete product line is available.Call us at WIRE-BOND: 800-849-6722.

www.wirebond.com

Printed in the U.S.A

Corporate Office400 Roundtree Rd PO Box 240988 Charlotte, NC 28224704 525.5554 800 849.6722 Fax 704 525.3761

Memphis Plant2365 Harbor Avenue PO Box 13124 Memphis, TN 38113

901 775.9444 800 441.8359 Fax 901 775.9449

Wire-Bond Clip

RJ-711 With Wire-Bond Clip

Series 900 Truss Type With Wire-Bond Clip

The WIRE-BOND clip is welded to hook. Continuouswire snaps into place providing a single unit for stability.WIRE-BOND clip may be welded into any system usingdouble hook for adjustment such as RJ-711 or double hookand eye system.

Conforms to building code requirements for masonrystructures (ACI530-95/ASCES-95/TMS402-95); seismicperformance categories A-E. All WIRE-BOND seismicproducts are fully tested. Call for test results.

All Wire-Bond seismic products meet Uniform BuildingCode requirements listed in 1403.6.4.2. “In seismic zones3 and 4, wall ties shall have a lip or hook on the extendedleg that will engage or enclose a horizontal joint reinforce-ment wire having a diameter of 0.148 inch (3.76mm) (No.9 B.W. gage) or equivalent. The joint reinforcement shallbe continuous with butt splices between ties permitted.”

Seismic Triangle With Wire-Bond Clip

Seismic Products

®

®

0452_08:0452_09 9/19/08 4:33 PM Page 8