Communication GUI Guide GXE600 Series TDKLambda Software License Agreement TDKLambda Corporation grants the right to use the provided software program and accompanying document (Software) under the provision of this Agreement. You shall agree to this Contract terms to use them. 1. Copyright The copyright of this software is owned by TDKLambda Corporation. The copyright of LabVIEW and NI Modbus Library is owned by National Instruments. 2. Scope of Use We only grant you the right to use the Software from the date you accepted the Software and agreed to this Agreement. Therefore, you must not transfer, rent, lease the software to a third party. 3. About copy, analysis and modification Under the terms of this Agreement, you shall not copy, analyze or modify it in whole or in part in any case. 4. Disclaimer Even if this software or the product of software itself directly or indirectly causes damage, we do not assume any responsibility for the damage. We do not be obliged to make corrections and support even if there is a deficiency in this software. We assume no responsibility for the effect of the result of using this Software. 5. General information If any provision or a part of provision of this Agreement becomes invalid by law, such part shall be deleted from this contract terms. 6. Other Matters not stipulated separately are subject to copyright laws and related laws and regulations. About registered trademark The following names used in the Communication GUI Guide are registered trademarks. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. LabVIEW is a registered trademark of National Instruments in the United States and other countries. MODBUS is a registered trademark of Schneider Automation Inc. GAXESS is a registered trademark of TDKLambda Corporation. 1/41 A2630403C GXE600 Series Communication GUI Guide

C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>

Software License Agreement

TDK­Lambda Corporation grants the right to use the provided software program and accompanying document (Software)under the provision of this Agreement. You shall agree to this Contract terms to use them.

1. CopyrightThe copyright of this software is owned by TDK­Lambda Corporation.The copyright of LabVIEW and NI Modbus Library is owned by National Instruments.

2. Scope of UseWe only grant you the right to use the Software from the date you accepted the Software and agreed to this Agreement.Therefore, you must not transfer, rent, lease the software to a third party.

3. About copy, analysis and modificationUnder the terms of this Agreement, you shall not copy, analyze or modify it in whole or in part in any case.

4. DisclaimerEven if this software or the product of software itself directly or indirectly causes damage, we do not assume any responsibility for the damage.We do not be obliged to make corrections and support even if there is a deficiency in this software.We assume no responsibility for the effect of the result of using this Software.

5. General informationIf any provision or a part of provision of this Agreement becomes invalid by law, such part shall be deleted from this contract terms.

6. OtherMatters not stipulated separately are subject to copyright laws and related laws and regulations.

About registered trademarkThe following names used in the Communication GUI Guide are registered trademarks.

・ Windows is a registered trademark of Microsoft Corporation in the United States and other countries.・ LabVIEW is a registered trademark of National Instruments in the United States and other countries.・ MODBUS is a registered trademark of Schneider Automation Inc.・ G­AXESS is a registered trademark of TDK­Lambda Corporation.

1/41 A263­04­03C

GXE600 SeriesCommunication GUI Guide

Page 2: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>2/41

Index1. GXE Access Installation

1.1 GXE Access Installation1.2 Connection with GXE1.3 Activate GXE Access

2 Screen layout and setup2.1 Screen layout2.2 Connection settings2.3 GXE settings

3. Graphical screen mode3.1 Main screen3.2 Tab screen3.3 GUI Configuration Tab3.4 PS Configuration Tab3.5 Trend Graph Tab3.6 VI Graph Tab3.7 Multi Monitor Tab3.8 E­CapLife Tab3.9 Advanced Tab

4. Manual screen mode4.1 Screen layout

4.1.1 GXE Output4.1.2 Tab area4.1.3 Meters4.1.4 Information display area

4.2 Holding Reg 14.2.1 GXE system settings4.2.2 Setting of reference value and protection threshold4.2.3 Setting of output rise time and transition time

4.3 Holding Reg 24.3.1 GXE PS Settings 24.3.2 GXE SCI Settings

4.4 Holding Reg 34.4.1 Scratch Pad 1, 2

4.5 Input Reg4.5.1 Read Product Information

5. Register List5.1 Input Registers5.2 Holding Registers5.3 Q format

Page 3: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>3/41

1 GXE Access Installation :The operation of MODBUS communication tool for GXE (GXE Access) requires GXE Access application and LabVIEW runt ime engine.Because GXE Access and LabVIEW Runtime Engine installer are integrated, they are installed at the same time by the following procedure.It has been confirmed that Windows 10 can operate in our environment.1.1 GXE Access Installat ionGXE Access is provided as a compressed file (Zip format).

After decompressing the compressed file, installing GXE Access is started by executing "setup.exe".in the subfolder "Volume" of the decompression dest ination.Follow the instructions on the screen.

Select installation directory, click "Next >>".

※ A license agreement screen will be displayed. Please review the license agreement. If you agree, select the acceptance checkbox, and click "Next >>".

Page 4: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>4/41

Click "Next >>", installation will start .※ Depending on the PC environment, it might take about 1 hour to install.

It might be necessary to restart the PC.

Please restart the PC following the instructions on the screen.

After installat ion process has finished, the compressed file and the decompressed folder are unnecessary.

Page 5: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>5/41

1.2 Connection with GXEWhen connecting multiple GXEs to the system, each GXE must have a unique slave ID.Before installing in the system, set the functions of each GXE so that the slave IDs do not overlap.To do the setup, connect your PC and GXE one to one with RS­485 line and execute GXE access on PC.Refer to "4.2 GXE communication sett ing" for operation method.Prepare USB ⇔ RS­485 converter for PC by yourself.It can be used as long as it is an RS­485 converter compatible with half duplex communication and automatic transmission control. The USB ⇔ RS­485 converter we confirmed the operation is "USB­003 of Human Data Ltd."Refer to the instruction manual of the converter and GXE for information of connector / cable wire diameter etc. used for connection.

・ConnectionBe sure to connect CN84 and then USB cable in order. After complete the connection, apply the input voltage to GXE.While the voltage is inputted to GXE or while communication tool is running, please do not disconnect communication line, attach / detach connector etc. etc.Even if the input voltage is cut off, there is a possibility that electric charge may remain at the output terminal.Be careful when removing the communication line.

1.3 Act ivation the GXE AccessAfter installation process has finished, "GXE Access" is registered in Windows start menu.Select an application from the following location in Windows start manu.

・Windows 10 Start MenuTDK­Lambda ⇒ GXE Access

※ If you changed the installation folder please refer to that.

⇒ Go to 「Start­up screen」

USB CN84(Communication

Port)

USB ⇔RS-485

converter

Page 6: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>6/41

2 Screen composition and environment settings :2.1 Screen modeGXE Access has two screen modes.GXE Access will be in "Graphical"screen mode at starting "GXE Access"or disconnecting communication.GXE Access can switch between the "Graphical" screen mode and the "Manual" screen mode after the communication connection is successful.

Screen mode OverviewGraphical A Graphical screen mode can be operated intuitively.

It is an application example using GXE. In the Graphical screen mode, communication is performed automatically.For details, refer to Chapter 3.

Manual Manual screen mode can be operated manually unlike Graphical screen mode.This mode can be operated each communication register.Therefore, it is suitable for operation confirmation of various registers.For details, refer to Chapter 4.

●Graphical screen mode

●Manual screen mode

Page 7: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>7/41

By clicking the [Connect] button, the GXE Access opens the specified COM Port and enters connection state.When the communication connection with GXE is successful, the "Tool Configuration" area turns to gray,and the "Connect" button changes to "Disconnect" and operat ions other than the GUI Configuration tab become operational.

In case of connection error, please make sure "COM Port" is set correctly.

Item OverviewUnit ID * Set the same value (1 to 247) as GXE to be connected.

Factory sett ing : "1"COM Port * Select the COM port number of the PC's RS ­ 485 port from the pull ­ down menu.

You can search for COM ports by specifying [Refresh] in the pull­down menu.Baud Rate * Set the same value as GXE to be connected.

Select from 2400, 4800, 9600 and 19200 bps.Factory sett ing:"19200 bps"

Parity Bit * Set the same value as GXE to be connected.Select from None (No Parity), Odd (Odd Parity) and Even (Even Parity).Factory sett ing: "Even"

T imeout * Set the timeout time (100 to 2000 ms) for communication error.The default value is 250 ms. If the t imeout is shorter than the default value,a timeout may occur before a normal response is returned.

Scan ID This function is used when the Unit ID is unknown.When the Scan ID button is clicked, the following dialog is displayed and brute force search is started.A brute force search stops when a Unit ID where a response is returned is found."Baud Rate" and "Parity Bit" will follow the currently displayed set ting."Scan ID" may take several minutes.

Connect / Disconnect Switch communication connection / disconnection.When the GXE access is disconnected, the COM port is released.

* : Last setting memory function is provided. The entered settings will be saved to the PC and will be reflected at the next time GXE Access is started.In the same environment as when you used it last time, you can connect PC and GXE simply by clicking "Connect".

Page 8: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>8/41

2.3 GXE settingsGXE set ting is necessary to control GXE output (using remote ON / OFF control function, CV / CC funct ion) with GXE Access.GXE set tings can be set on the "PS Configuration" tab. If the tab is not displayed, refer to "2.2 Connection sett ing".The necessary settings can be set automatically by "Automatic Settings" button.The set ting item changed by "Automatic Set tings" button can be returned to the factory shipping with "Factory Reset" button.For details of the setting, refer to "3.4 PS Configuration".The set ting can also be done in the manual screen mode. Refer to "4.2 Holding Reg 1".

"Factory Reset"button "Automatic Settings" but ton

Page 9: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>9/41

3 Graphical screen mode :This chapter is based on the Graphical screen mode. For details on screen switching, please refer to Chapter 2.

3.1 Screen layout

Graphical screen mode consists of main screen and tab screen.

Screen mode Overview

Main screen The main screen has measurement information, remote control function, etc.

Tab screen Tab is divided for each function.

However, if "GXE Access" and GXE are not connected,

only the [GUI Configuration] tab is displayed.

Communicat ion settings can be set on the "GUI Configuration" tab.

T he tab has the following structure.

Tab Overview

GUI Configuration Display communication setting and information on connected GXE.

PS Configuration PS Configuration tab has items necessary to operate GXE with GXE Access.

For more detailed settings, use the Advanced tab.

Trend Graph Display time change of GXE output voltage, output current, internal temperature.

VI Graph Display of output derating and its current output status.

Mult i Monitor Monitoring of multiple GXEs and acquisition of operat ion logs.

E­Cap Life Simple estimated lifetime is indicated from the degree of deteriorat ion of the

electrolytic capacitor

Advanced The setting list is displayed.

It is possible to save and read settings at once, reset to the factory shipment state.

Main screen

Tab screen

Page 10: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>10/41

3.2 Main screenThe main screen has measurement information, remote control function, etc.

1) ON/OFF button 2) Screen mode switching 4) LotNo. + Serial No. 5) Life of Electrolytic Capacitor 6) Operation time3) Unit ID

7) GXE internal Temperature 8) Tab display omitted button 9) Alarm History 10) Alarm History clear button

Item Overview

1 ON/OFF button Control ON / OFF of GXE. When an analog is selected in the remote control set ting,

"ON/OFF button" is not displayed.

2 Screen mode switching Switch the screen mode with "Graphical" ⇔ "Manual".

3 Unit ID T he Unit ID of the connection target is displayed. It is also possible to change.

4 LotNo. + Serial No. Displays the lot number and serial number of the connected GXE.

5 Life of Displays the predicted remaining time for electrolytic capacitor "Lo" in percent .

Electrolyt ic Capacitor For details, refer to "3.8 E­CapLife tab".

6 Operation time The cumulative operating time of the GXE is displayed. (not including Remote off time)

7 GXE internal The measured value of GXE internal temperature is displayed.

Temperature

8 Tab display omit ted It switch display / hide the tab screen.

button

9 Alarm History The alarm information of the protect ion operation that occurred is displayed.

In the communicat ion register, OVP is divided into SWOVP / HWOVP and

OCP is divided into SWOCP / HWOCP.

However, they are represented by OR in Grahical screen mode.

10 Alarm History Clear the Alarm History.

clear button However, if the cause of the Alarm History has not been removed, it can not be cleared.

Page 11: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>11/41

11) CV/CC status 12) Output voltage 13) CV target 14) Over voltage threshold

15) Over current protection mode 16) Output current 17) CC target 18) Over current protection thresholdItem Overview

11 CV/CC status Indicates that it is in CV control state or CC control state.

It is not displayed when the CV / CC target is "Digital".

12 Output voltage Indicates the output voltage of GXE. Numerical notat ion and bar meter are synchronized.

13 CV target CVCC target sett ing : Digital

The CV target is indicated by the slide bar and the numerical value and they are synchronized.

Slide bar accepts mouse operat ion. Numeric value input field is available with keyboard input.

CVCC target sett ing : Analog

The CV target is indicated by the slide bar and the numerical value and they are synchronized.

You can not operate both the numerical value and the slide bar.

* Please refer to "3.4 PS Configuration Tab" for Analog / Digital set ting of CV target.

14 Over voltage The Over voltage threshold is indicated by the slide bar and the numerical value,

threshold and these are synchronized.

Slide bar accepts mouse operat ion. Numeric value input field is available with keyboard.

15 Over current Indicates protection operation mode at Over current . The protection mode is determined by

protection mode the magnitude relationship between overcurrent protection threshold and CC target .

Over current protection threshold > CC target : Constant current Limit

Over current protection threshold ≦ CC target : Shutdown

16 Output current Indicates the output current of GXE. Numerical notation and bar meter are synchronized.

17 CC target CVCC target sett ing : Digital

The CC target is indicated by the slide bar and the numerical value and they are synchronized.

Slide bar accepts mouse operation. Numeric value input field is available with keyboard input.

CVCC target sett ing : Analog

The CC target is indicated by the slide bar and the numerical value and they are synchronized.

You can not operate both the numerical value and the slide bar.

* Please refer to "3.4 PS Configuration Tab" for Analog / Digital set ting of CC target.

18 Over current The Over current threshold is indicated by the slide bar and the numerical value,

protection threshold and these are synchronized.

Slide bar accepts mouse operat ion. Numeric value input field is available with keyboard.

Page 12: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>12/41

3.3 GUI Configuration TabThis tab displays the settings of "GXE Access" and the details of the connected GXE.This tab is forcibly displayed when GXE Access is started (before communication connection) and after communication was disconnected.

1) Communication tool settings 2) GUI Version 3) Connected GXE 4) Temperature notation

Item Overview

1 Communication tool settings For the communication tool setting field, refer to "2.2 Connection settings"

2 GUI Version Indicates the version of GXE Access currently in use.

3 Connected GXE Displays the details of the connected GXE. It is cleared when the GXE is disconnected.

4 Temperature notation Temperature notation ( Celsius[℃] / Fahrenheit[℉] ) can be switched.

Page 13: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>13/41

3.4 PS Configuration TabThis is a setting tab for controlling GXE with GXEAccess.The changed settings are retained even after the power input is shut down.

1) Remote control sett ing 2) CVCC target set ting 3) Communication settings

6) "Factory Reset" button 5) "Automatic Settings" button 4) ON / OFF data holding setting

Item Overview

1 Remote control set ting This is the remote control setting area of GXE.

It is necessary to set to "Digital" for remoto control by GXE Access.

The factory setting is "Analog".

Analog : Control ON / OFF of GXE by switching electrical contacts.

Digital : Control ON / OFF of GXE with communication signal.

Analog AND Digital : This mode turns on GXE when both electrical contacts and

communication signals are turned ON.

2 CVCC target setting This is the area for setting the CV / CC target source of GXE.

Unselected target input sources are ignored.

Analog : GXE works on the reference of output voltage variable volume

and the external voltage to the PV or CC terminal. *

Digital : GXE works on the reference by communication CV/CC target.

3 Communicat ion set tings This is the area for settings "Unit ID", "BaudRate", "Parity Bit" of GXE.

The setting is applied to GXE by clicking "APPLY" but ton.

After setting, GXE Access will be disconnected.

4 ON / OFF data It is a button which can change the holding characteristic of

holding setting the communication remote control ON / OFF signal.

If "Analog" is selected in the remote control setting, it will be grayed out.

・Volatile Mode

When the AC input of GXE is cut off and restarted,

the output of GXE will start from OFF each time.

・Non Volatile Mode

When the AC input of GXE is cut off and restarted,

the output of GXE is maintained in the state

before input shutdown.

5 "Automatic Settings" This button changes remote control setting and CVCC setting to "Digital".

button ON / OFF data holding setting is set to "Volatile Mode".

6 "Factory Reset" button This button changes the remote control set ting and CVCC set ting to "Analog".

* Refer to the instruction manual about PV terminal in detail.

Page 14: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>14/41

3.5 Trend Graph TabMeasurement data is displayed on this tab with time.The monitoring targets are "output voltage", "output current", "GXE internal temperature".This function is a simple graph display, there is no unit on the time axis.The graph is updated even when Trend Graph tab is not selected.

1) Output voltage / current axis 2) GXE internal temperature axis 3) Graph legends

Item Overview

1 Output voltage / current Scale for output voltage and output current.

axis T he unit is [V], [A]. Scale can not be changed.

2 GXE internal temperature Scale for GXE internal temperature. Scale can not be changed.

axis It is a unit of temperature notat ion set on "GUI Configuration" tab. ([℃] or [℉])

3 Graph legends T his is the legend of the displayed graph.

Page 15: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>15/41

3.6 VI Graph TabThis tab shows the output derating of GXE and the current operating point .Make sure that the GXE operating point is displayed inside the output derating curve.Please be careful that the operat ing point indication cannot follow when the load fluctuation is fast .

1) Output derating condit ion input field 2) Operating point 3) Output derating curve 4) Mounting type legend

5) Operating point position

Item Overview

1 Output derating condition T his is a field for entering conditions for drawing an output derating curve.

input field T a : Select the ambient temperature of GXE.

Utility Voltage : Select voltage input to GXE.

This function does not support input less than 100 Vac.

If input is less than 100 Vac, please check the instruct ion manual.

Mounting : Select the installation direction of GXE.

Refer to "Mounting type legend".

Cover : Select the presence or absence of the opt ional cover.

Cooling : Select whether the environment to be used is convect ion

or forced air cooling.

If you plan to use GXE with forced air cooling, please carefully review

  the specifications and instruction manual.

2 Operat ing point Indicates the current GXE operating point.

When the load fluctuation is fast, the operating point indication may not follow up.

3 Output derating curve This is the output derating curve of GXE.

The output derating curve depends on the output derating condition input field.

※ There is a region including error in the description. Please use with margin.

4 Mounting type legend Legend of GXE installation direction.

5 Operat ing point position Displays the GXE output operating point as a percentage of the rating.

Page 16: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>16/41

3.7 Multi Monitor TabThis tab monitors multiple GXE at the same time.There are variations in the update interval of the monitoring value.Also, as the number of act ive button checks increases, the update cycle is extended.Up to 10 monitoring is possible, but synchronization is not taken.The monitored data can also be saved as LOG data.The LOG operation continues even when the Mult i Monitor tab is deselected.

2) Unit ID input field 4) Output current indication 6) Alarm history indication1) Active button 3) Output voltage indication 5) Internal Temperture indicat ion 7) LOG status

Item Overview

1 Active button T he checked line will start monitoring.

During monitoring, the Unit ID is locked and can not be changed.

2 Unit ID input field Set the Unit ID to be monitored.

Baud Rate, Parity Bit depends on the setting on the GUI Configuration tab.

3 Output voltage indication Displays the monitored output voltage.

4 Output current indication Displays the monitored output current.

5 Internal Temperture Displays the monitored internal temperture.

indicat ion

6 Alarm history indication Displays the monitored protect ion operation history.

If there is more than one, one will be displayed as the representative.

7 LOG status Indicates the status of LOG processing.

8 LOG Start / Stop button This button manipulates the start / end of the LOG function.

Destination  : (My Documents)\TDK­Lambda\G­AXESS\GXE_Access\Log

File name  : GXE600_Mult iLog_yyyymmddhhmmss.csv

( The file name contains the time when LOG saving started. )

9 LOG Open button This is a button to open the save dest ination of LOG data on Windows Explorer.

・Log data sample

The figure below is a sample of the saved CSV file.

When there are multiple alarm histories, only one display was representative on the Multi Monitor tab. But LOG data will show all alarms.

Please confirm the T imestamp column by convert ing the display format to time in Excel.

Data acquisition time Unit ID , Output voltage, Output current , Internal Temperature Alarm History

8) LOGStart / Stopbutton

9) LOG Open button

Page 17: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>17/41

3.8 E­CapLife TabThis tab shows the expected remaining life of GXE.This function is effective only when GXE is used as the placement method of "MountA".The remaining life expectancy is calculated by calculating the remaining service life years from the "E ­ Cap Life" and "cumulative operating time" by a linear expression.This function is a just reference data, it does not guarantee the product life.

1) E­CapLife 2) Maximum Expected Life 3) Remaining life span 4) Usage environment input field

5) User device operation time 6) Update button

Item Overview

1 E­Cap Life Displays the predicted remaining life of electrolyt ic capacitor relative to Lo as a percentage.

E­Cap Life is also displayed on the main screen.

T he communication register specification returns the remaining life [hour]

when the electrolyt ic capacitor is at 105℃.

However, in Graphical screen mode, the remaining life is indicated by [%].

T he denominator is the initial value.

T he initial value is different for each voltage model, but it is automatically discriminated.

Initial value 24V 8000 [hour]

48V 10000 [hour]

2 Maximum Expected The maximum expected life is 15 years after delivery.

Life Because of deterioration of sealing rubber of electrolytic capacitor.

3 Remaining life span T he remaining life span is the t ime to reach 0% assuming that E­Cap Life decreases

in the primary equation.

T he value input from the use environment input column is added to the predicted

lifespan years.

The display limit is 15 years.

4 Usage environment This is a schedule input field using GXE.

input field You can enter the number of working days per week, the number of working hours per day.

As the default value, a value assuming 24 hours 365 days operation is entered.

5 User device This is the time that GXE cumulative operation t ime was reflected

operation time for the usage environment input field.

6 Update but ton When you click the UPDATE button, it is updated based on the value entered in the usage

environment input field.

Page 18: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>18/41

3.9 Advanced TabOn this tab all the settings will be displayed.However, excluding items that can be set in PS Comm. Configuration on the PS Configuration tab.You can also reset the GXE sett ing to factory default set tings.You can duplicate GXE with the same settings, save settings saved on GXE on PC.For details of each setting item, please see the communication manual.

1) Setting item list 3) Load button 2) PC ( GXE Access ) 6) Write but ton

4) Save button 7) Message display field 5) Read button 8) Default button

Item Overview

1 Setting item list A list of configurable items is displayed.

The changed value is writ ten to GXE when the "Write button" is clicked.

2 PC ( GXE Access ) It is an icon showing the data displayed in the sett ing item list .

3 Load button It is a button to read the setting list data saved on the PC.

When you click "Load button" a dialog will be displayed and you can select the target

to be read.

4 Save button It is a button to save the data currently displayed in "Set ting item list" on the PC.

When you click "Save button" a dialog will be displayed and you can select the save

destination.

5 Read button Read out various setting items set in GXE and display them in "Setting item list".

6 Write button Write various setting items displayed in "Setting item list" in GXE.

The settings written to GXE are saved in nonvolatile memory inside the GXE.

Therefore, the sett ings are retained even after GXE input is shut off.

7 Message display field A message indicating the processing status by the Advanced tab is displayed.

8 Default button Returns the setting of GXE to the factory default setting.

For the semi­standard model, GXE may return to the standard item setting.

Page 19: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>19/41

4 Manual screen mode :T his chapter is based on the Manual screen mode. For details on screen switching, please refer to Chapter 2.

4.1 Screen layout2) [Disconnect] Button

1) Screen mode switching 3) Unit ID 4) GXE Output area 5) Master Settings area 6) Tab display area

7) Information display area omitted button 8) Information display area

Item Overview1 Screen mode switching Switch the screen mode with "Graphical" ⇔ "Manual".2 [Disconnect] Button It disconnect with closed COM port of the PC.

After disconnection, it becomes the GUI Configuration tab of the Graphical screen mode.

3 Unit ID Displaying the ID of the connected GXE.It is also possible to change the connection destination by changing the value.Other communicat ion settings depend on settings on Graphical screen mode.

4 GXE Output area It is used to control the output of GXE with GXE Access.5 Master Set tings area This is the area to display / edit each measured value of GXE.6 Tab display area This is the area to display / edit the setting values of each function of GXE.

(details will be explained in the next chapter)7 Information display area It switch display / hide the Information display area.

omit ted button8 Information display area The status of GXE Access is displayed.

Page 20: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>20/41

4.1.1 GXE OutputWhen the Remote Control (RC) mode is other than "0" (AnalogRC) *, it is possible to control the output of GXE by operating the [GXE Output] area during connection status.* The factory default RC mode is set to "mode 0: AnalogRC" (remote control by communication is disabled).  For details on changing the RC mode, refer to "· RC Configuration [Remote CFG] Dialog".

The following two registers (volatile / non­volatile) are prepared for the output control register according to the usage purpose.The [Remote On] and [Remote Off] buttons control the output of GXE according to the control register setting (volatile / non­volatile).For details, refer to the "Remote On / Off" section of "4.4 Holding register details" in the communication manual.

Button GXE behaviorRemote On Issue a remote On query to the "volatile / non­volatile" register displayed in the control register.Remote Off Issue a remote Off query to the "volatile / non­volatile" register displayed in the control register.

Control register Register behaviorVolat ile Register contents are cleared after input shutdown.

(The GXE will be remote Off at the next input applied.)Non­Volatile The current register contents are retained even after input shutdown.

The control register is set automatically when GXE Access is connected with the GXE or when RC mode register is changed.Also, it can be manually operated.

Control Register

[Remote On] Button [Remote Off] Button Click the control register window and select the target register.

4.1.2 Tab screenRegisters are displayed in the tab display area, except for "GXE output control" and "measurement information".

Holding Reg1­3 : Readable / writable data such as setting registers are arranged.Input Reg : Read­only data other than measurement information is arranged.

Page 21: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>21/41

4.1.3 MetersThe monitor function of GXE is allocated as MODBUS register.

Polling checkbox

[Detail] button

[Alarm history clear] Button

[PF output time clear] Button

Item OverviewOutput Voltage Register data of measured value of output voltage (between + S and ­ S terminals)

and converted voltage value are displayed.Output Current Register data of measured output current value and converted current value are displayed.Analog CV Register data of measured voltage of analog PV terminal and converted voltage value are displayed.Analog CC Register data of measured current of analog CC terminal and converted current value are displayed.

Internal Temp.

T he alarm information of the protection operation that occurred is displayed.You can change the radix by clicking the radix* part in the display area.When you click the [Bits] but ton, detailed dialog of alarm history is displayed.For the detail dialog of alarm history, please see the next page.

NV Alarm History Same as above "Alarm History" but this is non­volatile history.Click the button to erase the contents of the [Alarm history] register.If the protection condit ion continues even after erasing, the alarm history is set again.Alarm history is deleted even when GXE output starts other than automatic restoration.

PF output t ime It is displayed that Accumulated time while the PF signal is out.[PF output time clear] button Click the button to erase the contents of the [PF output time] register.Operation Time T he cumulat ive operating time of the GXE is displayed. (not including Remote off time)E­cap L0 Remaining T he predicted lifetime of the electrolytic capacitor inside the

power supply (standard installation) is displayed as L0 parameter.Polling Select whether to enable automatic update of measurement information.

When "Polling" is checked, measurement information is automatically updated.Please note that when you uncheck it , the operation of the Multi Monitor tabin Graphical screen mode also stops.

* About display of radixRadix part

Click [Radix part] and select the display radix.Item OverviewDecimal It is expressed in decimal. "d" is displayed in the display area.Hex It is expressed in hexadecimal. "x" is displayed in the display area.Octal It is expressed in octal number. "o" is displayed in the display area.Binary It is expressed in binary notation. "b" is displayed in the display area.SI Notation It is expressed by an index. "p" is displayed in the display area.

Alarm History

[Alarm history clear] button

T he measured value of GXE internal temperature is displayed.(Because GXE is convection cooling, the value is affected by the installation state of GXE)

Page 22: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>22/41

・ Alarm History Dialog

By clicking the [Detail] button, detailed dialog of alarm history is displayed.In the dialog, the generated alarm will be lit .

Item OverviewSWOCP Indicat ion that overcurrent has been detected. The detection level can be changed with

the OCP threshold register. (Factory setting: 120%Typ. of the nominal current)HWOCP Indicat ion that overcurrent has been detected.

It operates when abnormality such as output short circuit occurs.Detect ion level cannot be changed and it is set larger value than SWOCP.

SWOVP Indicates that output overvoltage was detected between sensing terminals (between + S and­S terminals). The detect ion level can be changed with the OVP threshold register.

(Factory setting: 125%Typ. of the nominal voltage)HWOVP Indicat ion that output overvoltage was detected between output terminals (between +V and

­V terminals). Detection level cannot be changed. (Factory setting: 125%Typ. of the nominal voltage)

OTP Indicat ion that over temperature protection has been activated.INPUTLVP Indicat ion of the input voltage drop while remote on state. *RCOFF Indicat ion that the power supply is remote offSYSTEM Indicat ion that an error occurred inside the power supply.

If this error is occurred, please contact us.Reserved Alarm is not allocated because it is a reserved bit.

* INPUTLVP is set when the input voltage dropped in remote on state. To distinguish the normal cutting off of the input voltage by the user and abnormal input voltage drop, please obey the following sequence: First please remote off and then shut down the input.

4.14 Information display areaT he communication status of GXE Access and the error that occurred during register access are displayed in "Information display area".

78

9 ­ 13

5, 6, 14, 15

bit #0

1

2

3

4

Page 23: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>23/41

4.2 Holding Reg 1 :

[Read] Button 1) GXE PS Setting 1

Item OverviewClick the [Read] button to display the device settings of GXE. (All data at once)By clicking the [Edit] button, it is possible to edit detailed data on the dialog.In the communication register specifications, the CV/CC target value and protection thresholdare normalized.However, GXE Access automatically determines the voltage model and converts register values andvoltage / current notation.The time setting register is set by the time that each reference value is changed from 0% to 100%.By clicking the individual [Write] button, the setting value of GXE is updated to the edited data.

4.2.1 Acquisit ion / update of GXE system settingsFor the item whose radix is displayed at the left end of the display area, it is possible to change the display radix by clicking the radix part.

For details on the display radix, see "4.1.3 Meters".

The display data can be changed within the range described in "7. GXE register list".

Radix part [Edit] Button

Display area [Write] Button

The following data is displayed on the screen. For details, refer to each dialog section.Item OverviewRemote CFG This make settings related to remote On / Off function.CVCC CFG This make settings related to the CVCC function.Protect CFG This make settings related to the protection funct ion.

By clicking the [Edit] button in each item, it is possible to edit the data on the displayed dialog.You can also edit data directly in the display area.By clicking the individual [Write] button, the setting value of GXE is updated to the display area.When editing direct ly in the edit ing area, please confirm that the entered value matches the radix part.

GXE PS Sett ing 1

Page 24: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>24/41

・RC CFG DialogIn the dialog window, information on register data is displayed for each individual item.

By clicking on the RC Mode field, the choices are displayed.

Item OverviewRC Mode Click the display area and select the RC mode.

(The factory default RC mode is set to "mode 0: Analog RC")0 : Analog RC Enable input from the CNT terminal of CN84. * (Remote control by communication is invalid)1 : Digital RC (Volatile) Enable remote control by communicat ion. (Analog RC is invalid)2 : Digital RC (Non­Volatile) Enable remote control by communication. (Analog RC is invalid)3 : Mixed RC (Volatile) The logical AND of the analog RC and the digital RC (Volatile) is used as the remote control signal. 4 : Mixed RC (Non­Volatile) T he logical AND of the analog RC and the digital RC (Non­Volatile) is used as the remote control signal. In Mixed RC mode, the GXE output only when both analog RC and digital RC are remote ON.

Debounce Count Sets the filter t ime for removing the bounce of the analog CNT pin.Enter a value between 0 and 100 [ms] directly in the edit area. (Factory sett ing 10 [ms])

* Refer to the instruction manual about CNT terminal in detail.

The following table shows the relationship between remote control input combinations and power output in each RC mode.

Analog RC Digital RC Volatile Non­VolatileEnable invalid OFF x x OFF

ON x x ONDisable valid x OFF x OFF

(Volatile) x ON x ONDisable valid x x OFF OFF

(Non­Volatile) x x ON ONEnable valid OFF x

(Volatile) ON xOFF xON x ON

Enable valid x OFF(Non­Volatile) x ON

x OFFx ON ON

x : It is not referred.By clicking the [OK] button, the data in the display area is updated based on the setting on the dialog.Please close the dialog and then click the [Write] button.Otherwise GXE sett ings will not be updated, so please be careful.

OutputValue

Digital RC

OFF

ON

1

2

3OFF

OFF

ON

0(Factory setting)

Control mode AnalogRC

4OFF

Page 25: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>25/41

・CVCC CFG DialogIn the dialog box, the enable / disable of digital CV and digital CC is displayed in check box format.Data of reserved bits cannot be changed.

*Factory set tingbit # Item Overview

0 Digital CV Checked. : The communication register value is enabled as CV reference.enabled No check* : The PV terminal voltage of CN84 or internal trimmer are enabled as CV reference.

1 Digital CC Checked. : The communication register value is enabled as CC reference.enabled No check* : The CC terminal voltage of CN84 is enabled as CC reference.

(CC is set to 115%Typ. when the CC terminal is open)By clicking the [OK] button, the data in the display area is updated based on the setting on the dialog.Please close the dialog and then click the [Write] button.Otherwise GXE sett ings will not be updated, so please be careful.

・Protect CFG DialogIn the dialog box, enable / disable of latched off is displayed in check box format.

CheckedWhen the protection function operates, the output of the power supply will be latched off.To reset the latched off, the remote Off to On or re­input the power source are required.

No checkWhen the protection function operate, the output ofthe power supply will automatically recovery.The recovery time can be adjusted with the automatic recoverytime setting register.

For details of each alarm, refer to "2.7.4 Alarm History Dialog".bit # Item Factory setting Protection mode

0 SWOCP * No check Auto recovery2 SWOVP Checked Latched off3 HWOVP Checked Latched off

* When the SWOCP threshold is larger than the CC reference value, SWOCP will not operate and the output voltage becomes constant current voltage droop by CC control.Since the CC reference value at factory setting is set smaller than the threshold value of SWOCP, the output voltage at overload becomes constant current voltage droop.

By clicking the [OK] button, the data in the display area is updated based on the setting on the dialog.Please close the dialog and then click the [Write] button.Otherwise GXE sett ings will not be updated, so please be careful.

Page 26: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>26/41

4.2.2 Setting of reference value / protection thresholdThe display and editing area has two types of register value notation and register value conversion notation. They are synchronized.When you click the [Write] button arranged in each item, the changed data is written to GXE.

Display and edit area (Register value) Display and edit area (Register conversion value)

[Write] Button

Item Overview

Digital CV Set the reference value of the output voltage when the digital CV function is enabled.In the display area, the left side is the register data and the right side is the voltage conversion value.The register data is the normalized reference value with the nominal voltage [Q10 format *]The register value can be set within the range of 0.0 [Q10] to 1.3 [Q10].(1.3 t imes the nominal voltage is the upper limit)If a value out of upper range is entered, 1.3 [Q10] is set.Product specifications range from 0.2 to 1.2 times the nominal voltage.Factory sett ing : 1.0[Q10] (1.0 t imes the nominal value)

Digital CC Set the reference value of the output current when the digital CC function is enabled.In the display area, the left side is the register data and the right side is the current conversion value.The register data is the normalized reference value with the maximum current[Q10 format]The register value can be set within the range of 0.0 [Q10] to 1.15 [Q10].(1.15 t imes the maximum current is the upper limit)If a value out of upper range is entered, 1.15 [Q10] is set.Product specifications range from 0.2 to 1.15 times the maximum current.Factory sett ing : 1.15[Q10] (1.15 times the maximum current)

OVP Threshold Set detection threshold of SWOVP (software overvoltage protection).In the display area, the left side is the register data and the right side is the voltage conversion value.Register data is normalized with threshold of nominal voltage [Q10 format]The register value can be set within the range of 0.2 [Q10] to 1.25 [Q10].(1.25 t imes the nominal voltage is the upper limit)If a value out of upper range is entered, 1.25 [Q10] is set.Factory sett ing : 1.25[Q10] (1.25 times the nominal voltage)

OCP Threshold Set detection threshold of SWOCP (software overcurrent protection).In the display area, the left side is the register data and the right side is the current conversion value.Register data is normalized with threshold of nominal current [Q10 format]The register value can be set within the range of 0.2 [Q10] to 1.20 [Q10].(1.20 t imes the maximum current is the upper limit)If a value out of upper range is entered, 1.20 [Q10] is set.Factory sett ing : 1.20[Q10] (1.2 times the nominal current)To enable SWOCP, set the threshold smaller the CC reference value.

* For the Q10 format, refer to "5.3 Q format data".

Page 27: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>27/41

4.2.3 Setting of output rise time and transition time

Display and edit area [Write] Button

Item OverviewCV Rising T ime Set the time to specify the voltage slew rate (dv / dt) at the start of output.

The value is specified as the time required for the CV reference value to change from 0% to 100%.Register value can be set in the range of 20 [ms] to 10000 [ms]. (factory setting: 20 ms)

CC Rising T ime Set the time to specify the current slew rate (di / dt) at the start of output.The value is specified as the time required for the CC reference value to change from 0% to 100%.Register value can be set in the range of 20 [ms] to 10000 [ms]. (factory setting: 20 ms)

CV T ransit ion Time Set the time to specify the voltage slew rate (dv / dt) when the CV reference value is changed during steady output at RC ON state.The value is specified as the time required for the CV reference value to change from 0% to 100%.The set time is applied when the next AC turn­on or remote control turns OFF → ON.Register value can be set in the range of 20 [ms] to 10000 [ms]. (factory setting: 20 ms)

CC T ransit ion Time Set the time to specify the voltage slew rate (di / dt) when the CC reference value is changed during steady output at RC ON state.The value is specified as the time required for the CC reference value to change from 0% to 100%.The set time is applied when the next AC turn­on or remote control turns OFF → ON.Register value can be set in the range of 20 [ms] to 10000 [ms]. (factory setting: 20 ms)

* It depends on the system configuration whether or not actual change in output is in accordance with the set value.

By clicking the [Write] button arranged for each item, the changed data is written to GXE.

When a capacitive load such as a bat tery is connected to the power supply, overcurrent may occur at the t ime of output start or change of command value.In that case, there is a possibility of improvement by adjusting the slew rate with the register of this section.

Page 28: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>28/41

4 .3 Ho ld ing Reg 2 :

During communicat ion connection, click on the [Holding Reg2] tab, the screen of Holding Reg 2 will be displayed.

1) GXE PS Setting 2 2) GXE SCI Settings

Item Overview

GXE PS Set ting 2 Click the [Read] but ton to display the device settings of GXE. (All data all at once)Clicking the individual [Write] button updates the setting value of GXE to the edited data.

GXE SCI Settings Use to change the communication sett ing of the connected GXE.Click the [Read] but ton to display the GXE communicat ion set tings.Click the [Write] button to update the GXE communicat ion settings.The changed communicat ion set tings become effective when you click

the [Activate] button or re­input the power source.

Page 29: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>29/41

4.3.1 GXE PS Settings 2Click the [Read] but ton to display the device settings of GXE. (All data all at once)The display data can be changed within the range described in "7. GXE register list".

Display and edit area [Write] Button

[Read] Button

Item OverviewPF Threshold Sets the PF (Power Fail) threshold value for the signal output.

The threshold value is applied to the CV reference value or the CC reference value according to the mode setting.The value can be set within the range of 50 [%] to 95 [%] of CV reference value or or CC reference value. (factory setting: 80%)

PF Mode Sets the operat ion mode to perform PF judgment.Click the display area to select the mode.CV PF : When the output voltage falls to the PF threshold, the PF signal is output .CC PF : When the output current becomes less than the PF threshold, the PF signal is output.Factory setting:CV PF

PF Count Set the time to check keeping PF state from when PF is detected untilwhen PF signal is actually output .Set ting the PF count prevents the PF signal from being erroneously output due to noise or the like.The value can be set in the range of 0 [x 1 ms] to 100 [x 1 ms]. (Factory setting: 0 count = 0 ms)

Auto Recovery Sets the recovery time of output when protection set for auto recovery is activated.  If the protection factor continues to occur, the output is shut down again after the automatic recovery time has elapsed.  At the same time, if protection set for latch stop is occurring, output will not be recovered even if the automatic recovery time elapses.

The value can be set in the range of 100 [x 10 ms] to 1000 [x 10 ms]. (Factory setting: 100 count = 1 sec)

· Example of PF set ting (24 V model)CV reference value : 0.85 (24 V x 0.85 = 20.4 V)PF Mode : CV PF PF Threshold : 80 %

PF threshold voltage = CV reference value x PF threshold = 20.4 V x 80 % = 16.32 V

Please change PF settings as appropriate according to your system.If the automatic recovery time is set to be very short and the automatic recovery is repeated, the cooling time during power off may be insufficient and the operat ion of "OTP" or the power supply may be damaged.

By clicking the [Write] button arranged for each item, the changed data is written to GXE.

Page 30: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>30/41

4.3.2 GXE SCI SettingsYou can change the communication settings of the connected GXE with [GXE SCI Sett ings].The display data can be changed within the range described in "7. GXE register list".Set the value to be used when communicating from the next starting time.

When connecting multiple GXEs to the RS ­ 485 bus line, the slave IDs of each power supply must be different from each other.First, connect the PC and GXE one to one. Then, change the GXE 's slave ID with the register function shown in this section. After that, connect the GXE to the system's RS ­ 485 bus line.

[Write] Button

[Read] Button

[Activate] Button

The following data is displayed on the screen.Item OverviewUnit ID Set the slave ID of the GXE.

Set the ID to a different value for each MODBUS device connected to the same RS ­ 485 bus line.The ID can be set within the range from 1 to 247. (Factory setting : 1)

Baud Rate[bps] Set the Baud Rate of GXE.Click the display area and select the Baud Rate.Select Baud Rate from 2400, 4800, 9600 and 19200 [bps]. (Factory sett ing : 19200)

Parity Bit Set the transmission configuration of the GXE.Click the display area and select the parity.Select parity from None (no), Odd (odd number) and Even (even number). (Factory setting : Even)

* Stop bits are set automatically according to "Parity set ting".

By clicking the [Write] button, the changed data is written to GXE.In order to activate the written communicat ion setting, the input of the GXE is need to re­input again.If you want to activate the written communication settings immediately, please click the [Activate] button.Since the GXE communication settings are changed, you need to reconnect with the changed communicat ion settings.

­ When communication setting becomes unknown ­If the setting value becomes unknown after GXE communicat ion set ting is changed, communication set ting can be set to the factory setting state.For details, please refer to Supplementary items (1. Communication setting switch)

in the communicat ion manual.

Page 31: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>31/41

4.4 Holding Reg 3 :

During communicat ion connection, click on the [Holding Reg3] tab, the screen of Holding Reg 3 will be displayed.

1) Scratch Pad 1 2) Scratch Pad 2

Item Overview

Scratch Pad 1

Scratch Pad 2

The scratch pad is a register that you can store data freely.By clicking the [Read] but ton, data is displayed from GXE.Click the [Write] button to update the stored data of GXE with display data on the screen.

Page 32: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>32/41

4.4.1 Scratch Pad 1, 2The scratchpad is a non­volatile memory area on GXE that is open for the host device to which GXE is connected.Scratch pad data can be rewritten freely.GXE only saves data, it does not refer to data as control parameter.

When you click the [Read] button, the saved data is acquired in GXE and displayed on the screen.(There is no saved data at factory shipment.)

[Write] Button Display style setting Display and edit area

[Read] Button

In the display area, data of 30 characters or less in ASCII characters can be saved.The display style can be changed by clicking the [Display style setting].Click the [Write] button to save the data to GXE.* The image is the scratch pad 1, but the scratch pad 2 is the same.* Do not guarantee the saving of data other than ASCII characters.

Data cannot be overwritten when the display data is highlighted.Please edit the data after canceling or deleting the highlighted part.

Page 33: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>33/41

4.5 Input Reg :

During communicat ion connection, click on the [Input Reg] tab, the screen of Input Reg will be displayed.

1) Product Info.

Item OverviewProduct Info. Click the [Read] button to display the product information acquired

from GXE.

4.5.1 Read Product Info.By clicking the [Read] but ton, the product information data of GXE is displayed in each item of the display area.

Display area [Read] Button

The following data is displayed on the screen.Item OverviewModel Name The model name registered in the product is displayed.Serial No. The serial No. registered in the product is displayed.Lot No. The lot No. registered in the product is displayed.Firmware Ver. The firmware version registered in the product is displayed.

This register is 4­digit BCD (Binary coded Decimal) data of 16 bits and corresponds to the version number. The upper 1 digit indicates the integer part,and the lower 3 digits indicate the decimal part.

Page 34: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>34/41

5 Register List :In GXE, Input Register and Holding Register of 16­bit data are used in the data model specified by MODBUS protocol.Discrete Register and Coil Register of 1 bit data are not used.The register address of GXE in this communication manual is indicated by the PDU address.If a register that does not exist is used as the starting address, it becomes an exception response.For details, please refer to the communication manual.

・Numerical notat ionNumbers starting with '0x' indicate hexadecimal numbers. (Example : 0x0400 = 1024d)Decimal numbers are indicated by appending 'd' after the value or without adding anything. (Example : 1024d , 1024)Binary numbers are indicated by appending '0b' before the value. (Example : 0b0100 0000 0000 = 1024d)The internal data type of GXE is 16 bit little endian. ( LSB: bit 0 / MSB: bit 15 ) Negative values are represented in two's complement.

・Representation of constant voltage referenceConstant voltage reference is represented as "PV(Programmable Voltage) reference" in the instruct ion manual.In this document, it is represented as "CV reference" and they are synonymous.

5.1 Input RegistersInput Registers are read­only 16­bit data registers. Mainly, Input Registers has measurement data.

# Qty.1 Alarm History (Volat ile) 0 (0x0000) 1 Indicates protect ion content that occurred.

Indicates that overtemperature protection has been act ivated.Indicates that the booster output inside the power supply has decreased.Reserved bit Indicates that input voltage has decreased while remote on. *Indicates that the power supply is remote offIndicates that an error occurred inside the power supply.Reserved bit

Please contact us when the SYSTEM error occurs.* This is not available for the firmware version 3.000 and 3.001.

2 Output Voltage 1 (0x0001) 1 The value of the output voltage (between + S and ­S terminals) is indicated in normalized signed Q10 format.

3 Output Current 2 (0x0002) 1 The output current value is indicated in normalized signed Q10 format.4 Internal Temperature 3 (0x0003) 1 The measured value of GXE internal temperature is indicated.5 Operation T ime 4 (0x0004) 2 The cumulative operating time of the power supply is indicated.6 E­Cap L0 Remaining 6 (0x0006) 1 Among the electrolyt ic capacitors inside the power supply,

the predicted lifetime value of the most degraded capacitor is indicated.The mounting direct ion of power supply is assumed to be "Mount A"Please use as a guide only.

7 Analog CV Reference 7 (0x0007) 1 The analog CV voltage value is indicated in normalized signed Q10 format.8 Analog CC Reference 8 (0x0008) 1 The analog CC current value is indicated in normalized signed Q10 format.9 PF Output Time *1 9 (0x0009) 1 It is indicated that the integrated time value while the PF signal is out .

10 Alarm History (Volat ile) *1 20 (0x0014) 1 Same function as #1.11 Alarm History (Non­Volat ile) *1 21 (0x0015) 1 Same function as #1 but it is non­volat ile.12 Model Name 500 (0x01F4) 15 The model name registered in the product is indicated.13 Serial No. 520 (0x0208) 8 The serial No. registered in the product is indicated.14 Lot No. 540 (0x021C) 8 The lot No. registered in the product is indicated.15 Firmware Ver. 1000 (0x03E8) 1 The firmware version registered in the product is indicated.

*1 These registers are not available for the firmware version 3.000 and 3.001.

Input Register Starting Address Function

bit Name Overview

2 SWOVP Indicates that output overvoltage wasdetected.3 HWOVP

0 SWOCP Indicates that output overcurrent has beendetected.1 HWOCP

14, 15 reserved

4 OTP

5 PFCLVP

6 reserved

7 INPUTLVP

8 RC OFF

9­13 SYSTEM

Page 35: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>35/41

5.2 Holding RegistersHolding Registers are readable / writable 16­bit data registers.The data is arranged that can be changed from the host device such as the power supply setting.Unless otherwise specified, each set value is retained even after GXE input is shut down.

# Starting Address Qty. Function1 Remote On / Off 0 (0x0000) 1 Register for remote control (RC) by communication.

(Volatile) The power will be remote off at the next input.This register is not retained after GXE input is shut down.

Remote On / Off 5 (0x0005) 1 Register for remote control by communication.(Non­Volatile) Remote On / Off information that was set

before input shutdown is applied at next input.· Common items of volatile / nonvolatile registers

Remote control of GXE output by writing the reference valueto the register.

The register setting valueValue Function Overview

0 * Remote Off Output Off is commanded.1 Remote On Output On is commanded.

* Factory settingIt is necessary to change to the setting where communication input function is enabled with Remote Control Configuration register.Since the remote On / Off register is not referenced depending on the set value of the RC Configuration register, make appropriate settings according to the system.

2 Remote Control Configuration 100 (0x0064) 1 Register for setting related to remote control function.(RC Configuration) Set the remote control mode and set the Debounce Count

at analog RC.The register setting value

Byte Function Max. Min. Factory Setting

LSB RC Mode 4 0 0MSB Debounce Count 100 0 10

Holding Register

Page 36: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>36/41

# Starting Address Qty. FunctionRemote Control Configuration ・RC Mode

GXE has two remote control signals of analog RC input and communication RC input.

Value Overview0 The analog RC input is used as

the remote control signal.Communication RC input is not referred. (Factory setting)

1 The volatile remote On / Off register is used as the remote control signal.Analog RC input is not referred.

2 The Nonvolatile remote On / Off register is used as the remote control signal.Analog RC input is not referred.

3 The logical AND of the analog RC and the volatile remote On / Off register is used as the remote control signal. Output is turned On when both inputs are remote On.Nonvolatile remote On / Off registers are not referenced.

4 The logical AND of the analog RC and the Nonvolatile remote On / Off register is used as the remote control signal. Output is turned On when both inputs are remote On.Volatile remote On / Off registers are not referenced.

・Filter sensitivityBounce (chattering) may occur due to the input signal from the external terminal.The GXE has a bounce removal function, and the bounce removal intensity can be adjusted by setting the filter sensitivity.

The register setting valueMax. Min. Factory settt ing Unit

Integer data 100 0 10 ms

3 CVCC Reference Configuration 101 1 Register for setting the output reference value.GXE has two output reference, which are PV / CC terminal reference (Analog CV / CC) and CV / CC communication reference (Digital CV / CC).CV reference : The output voltage reference is selected.CC reference : The output current reference value is selected.

The register setting valueFunction Digital Analog Factory settt ing

CV reference 1 0 0CC reference 1 0 0

reserved ­ ­ ­

  For example, when the external terminal input (Analog) is selected,

  the set value of the communication register is not referenced.

2 ­ 15

Holding Register

Data form

(0x0065)

bit01

Page 37: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>37/41

# Starting Address Qty. Function4 Protect Configuration 102 1 Register for set ting protection function.

It is possible to select latched off or auto recovery for some protection functions.

Possible / Impossible to chagePossible (Factory setting : auto recovery)ImpossiblePossible (Factory setting : latche off)Possible (Factory setting : latche off)

When set to "auto recovery", the stop state is released after the time set in the auto recovery t ime register elapses.If the protection factor continues to occur, the output is shut down again after the auto recovery time has elapsed.

5 Digital CV Reference 103 1 Register for set ting output voltage reference value.When communication input is selected in the CVCC sett ing register, the output voltage reference value is specified with the Q10 format data normalized by the nominal voltage.It depends on the system configuration whether or not actual change in output is in accordance with the set value.

The register setting valueMax. Min. Factory setting Unit

Q10 format data 1.3 0 1.0 ­(Integer notation) 1331 0 1024 ­

6 Digital CC Reference 104 1 Register for set ting the output current target value.Specify the reference value of the output current when communication input is selected in the CVCC setting register.Changes in the actual reference value are affected by the slew rate setting register.Depending on the load impedance, the output current may not follow the CC reference.

The register setting valueMax. Min. Factory setting Unit

Q10 format data 1.15 0 1.15 ­(Integer notation) 1177 0 1177 ­

7 Over Voltage Threshold 105 1 Register for set ting output overvoltage threshold.Specify the detection threshold of SWOVP with Q10 format data normalized by the nominal voltage.

The register setting valueMax. Min. Factory setting Unit

Q10 format data 1.25 0.2 1.25 ­(Integer notation) 1280 204 1280 ­

Holding Register(0x0066)

bit Name0 SWOCP1 HWOCP2 SWOVP3 HWOVP4 OTP

Impossible

5 PFCLVP6, 7 reserved

8 RC OFF9­13

Data form

(0x0069)

Data form

SYSTEM14, 15 reserved

(0x0067)

Data form

(0x0068)

Page 38: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>38/41

# Starting Address Qty. Function8 Over Current Threshold 106 1 Register for setting overcurrent threshold.

Specify SWOCP detection threshold with Q10 format data normalized with maximum current .

The register sett ing valueMax. Min. Factory sett ing Unit

Q10 format data 1.2 0.2 1.2 ­(Integer notation) 1229 204 1229 ­

9 CV Rising T ime 107 1 Register for set ting the CV reference slew rate at the start of output.Specify the CV reference slew rate (dv / dt) at the start of output.

The register sett ing valueMax. Min. Factory sett ing Unit

Integer data 10000 20 20 ms

10 CC Rising T ime 108 1 Register for setting the CC reference slew rate at the start of output.Specify the CC reference slew rate (di / dt) at the start of output.

The register sett ing valueMax. Min. Factory sett ing Unit

Integer data 10000 20 20 ms

11 CV Transit ion T ime 109 1 Register for setting CV reference value slew rate at steady output.Specify the CV command slew rate (dv / dt) at steady output.

The register sett ing valueMax. Min. Factory sett ing Unit

Integer data 10000 20 20 ms

12 CC Transit ion T ime 110 1 Register for setting CC reference value slew rate at steady output.Specify the CC command slew rate (di / dt) at steady output.

The register sett ing valueMax. Min. Factory sett ing Unit

Integer data 10000 20 20 ms

13 PF Threshold 111 1 Register for setting PF (Power Fail) detection threshold.Specify the detection threshold when the PF signal is output.

The reference value is selected by sett ing the PF mode register.The register sett ing value

Max. Min. Factory sett ing UnitInteger data 95 50 80 %

14 PF Mode 112 1 Register for setting PF detection mode.Specify the detection target (output voltage or output current) of PF.CV Mode (Value 0) : When the output voltage drops below the PF threshold value, the PF signal is output.CC Mode (Value 1) : When the output current drops below the PF threshold value, the PF signal is output.

The register sett ing valueCV PF CC PF Factory sett ing Unit

Integer data 1 0 0 (CV) ­

(0x006C)

Holding Register(0x006A)

Data form

(0x006B)

Data form

Data form

(0x0070)

Data form

Data form

(0x006D)

Data form

(0x006E)

Data form

(0x006F)

Page 39: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>39/41

# Starting Address Qty. Function15 PF Count 113 1 Register for PF count set ting.

Set the t ime from when PF is detected until when the PF signal is actually output.When the output continues to be below the PF detection threshold for more than the t ime set in the PF count register, the PF signal is output.

The register sett ing valueMax. Min. Factory sett ing Unit

Integer data 100 0 0 ms

16 Auto Recovery T ime 114 1 Register for setting automatic recovery time.Specify the waiting time until the output returns when the protection function set for automatic recovery is activated.

 If the protection factor continues to occur, the output is shut downagain after the automatic recovery t ime has elapsed.

The register sett ing valueMax. Min. Factory sett ing Unit

Integer data 1000 100 100 10msFactory sett ing: 100 x 10 ms = 1 sec

17 Clear Alarm History 115 1 Register for clearing the alarm history.Clear the contents of the alarm history register.If the protection factor continues, the continuation factor bit is set again after clearing.

The register sett ing valueClear No action Factory sett ing Unit

Integer data 1 0 ­ ­* This register is write­only.

18 Clear PF Output T ime *1 116 1 Register for clearing the PF output t ime.Clear the contents of the PF Output T ime register.

The register sett ing valueClear No action Factory sett ing Unit

Integer data 1 0 ­ ­* This register is write­only.

*1 These register is not available for the firmware version 3.000 and 3.001.

Data form

Data form

(0x0074)

(0x0073)

Holding Register(0x0071)

Data form

(0x0072)

Data form

Page 40: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>40/41

# Starting Address Qty. Function19 Slave ID 200 1 Register for sett ing the slave ID.

For each GXE connected to the communication bus line, a unique slave ID must be set .Before connecting to the communication bus line, update this register value.

The register sett ing valueMax. Min. Factory sett ing Unit

Integer data 247 1 1 ­* To avoid misconfiguration, broadcast updates are ignored.

20 Baud Rate 201 1 Register for communication speed sett ing.The communication speed of GXE is specified by the register value shown below.

The register sett ing value

Set the communication speed to 2400 bps.Set the communication speed to 4800 bps.Set the communication speed to 9600 bps.Set the communication speed to 19200 bps. *

*Factory sett ing21 Parity 202(0x00CA) 1 Register for sett ing parity.

Specify the configuration of the GXE transmission code with the register value shown below.

The register sett ing valueOverview

No parity, 2 stop bits are set.Odd parity, it is set to 1 stop bit .Even parity, it is set to 1 stop bit . *

*Factory sett ing22 Scratch Pad 1 300(0x012C) 15 Register for scratchpad 1.

Scratch Pad 2 320(0x0140) 15 Register for scratchpad 2.· Common items of scratch pad 1/2 register

The scratch pad register is a register that you can freely store data.Up to 30 characters can be stored in ASCII characters.Do not guarantee the saving of data other than ASCII characters.

2

Value Overview

Value01

Holding Register

0123

(0x00C8)

Data form

(0x00C9)

Page 41: C o mm unic a t io n G U I G uid e GXE 60 0 Seri es Com ...€¦ · C o mm unic a t io n G U I G uid e GXE 600 Se ri es TDK Lamb da 3/41 1 GXE Ac c e s s Ins tal l ati

Communication GUI GuideGXE600 SeriesTDK­Lambda

<Page>41/41

5.3 Q formatQ format is a numerical type for handling decimal virtually with integer data.GXE treat all values as integers (Binary numbers).So GXE handles numeric values with Q format data when you need decimal values.In the Q format, when written as Q"n" format, data is handled assuming that there is a decimal point between the "n" th bit and the "n ­ 1" th bit of the data.

Example ) 1.25 [Q10]1.25 [Q10] = 1.25 x 210 = 1280d = 0x0500 = 0b0000 0101 0000 0000 In the case of a signed integer,

"b15" is sign bit.20 + 2­2 = 1 + 0.25 = 1.25

The numerical resolution becomes 2­n. Example) In Q10 format, 2­10=1/1024Therefore, for values that cannot be divided by 2­n, it shall be an approximate value.For example, when decimal number is 0.1, decimal operation can be divided by first decimal place and value can be accurately expressed.However, because binary operation cannot divide the value, truncation errors occur even if the number of digits in the decimal part is increased.

Assuming that it is expressed in Q16 format [16 decimal places]0.1 [Q16] = 0.1 x 216 = 6553d = 0x1999 = 0b0001 1001 1001 1001

It becomes a circulating binary decimal of 1100 from the bit weight of 2­4.Returning the value of this binary number to decimal number, it will be 0.0999908447265625.(it will not be exact 0.1)Because it is a circular decimal, truncation errors do not disappear even if infinitely increasing the number of digits.

・When the numerical data is normalizedThe actual value is the reference value when the normalized data is 1.0.As the numerical value becomes a decimal number, GXE handles normalized data in Q format.

・Conversion of physical quantity (voltage and current) and normalized dataNormalized data = physical quantity / reference valuePhysical quantity = reference value x normalized data

・Example of output voltage measurement value of 24V modelReference value = Nominal voltage = 24 [V]When the output voltage = 23.5 [V]Normalized data = 23.5 / 24 = 0.97917Q format representation of normalized data

Q10 format: INT (normalized data * 210) = 1002d = 0x03EAQ14 Format: INT (normalized data * 214) = 16042d = 0x3EEA

Conversely, when converting the normalized data expressed in the Q format to the physical quantityPhysical quantity = reference value x Qn format data x 2 ­ n

0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 b0 0

b1 b2 b3 b4 b5 b6 b7 b8 b9 b10 b11 b12 b13 b14 b15

仮想小数点

2-1

2-2

2-10

21

20

25

ビット重み整数部 小数部

Virtual decimal point

Bit weightDecimalInteger