7/28/2019 Cable Sheath Voltage Limiters Presentation
1/8
Power System Equipment Solutions to meet your needs
AK Power Solutions
HV Cable Sheath Voltage
Limiters
7/28/2019 Cable Sheath Voltage Limiters Presentation
2/8
Power System Equipment Solutions to meet your needs
HV Cable Earthing Link Boxes
AK Power Solutions has supplied HV CableSheath Earthing Link Boxes since 1989
Countries that have been supplied include
Australia, UK,
Europe,
Middle East, USA,
China,
New Zealand,
Singapore, Malaysia and
Indonesia
7/28/2019 Cable Sheath Voltage Limiters Presentation
3/8
Power System Equipment Solutions to meet your needs
H.V. Cable Sheath Voltage Limiters
7/28/2019 Cable Sheath Voltage Limiters Presentation
4/8Power System Equipment Solutions to meet your needs
H.V. Cable Sheath
Voltage Limiters
Designed, manufactured and tested in Australia by AK Power Solutions
Used on major cable projects up to 800kV throughout Australia andinternationally
Highly reliable and effective at managing cable sheath voltage risesand the associated power flows that can result under fault conditions
Competitively priced providing valuable protection to expensive cableinstallations
Available in 3.0kV, 4.5 kV, 6.0kV, 7.5kV and 9.00kV voltages othervoltages as required by clients
Suitable for Indoor or Outdoor Applications
7/28/2019 Cable Sheath Voltage Limiters Presentation
5/8Power System Equipment Solutions to meet your needs
HV Cable Sheath Voltage Limiters
Due to a highly non-linear and non-ohmic current-voltagecharacteristic, the sheath voltage limiters do not conduct anysignificant current during normal and fault-operatingconditions regardless of the magnitude of power frequency
induced voltages. For this application the function of surge arresters is limited
only to protect the cable anti-corrosion jacket and bondingsystem against switching and lightning surges to values
below the breakdown strength of protected elements. As a consequence all elements of the cable bonding system
must be designed to withstand the induced power frequencyvoltages, both during normal and fault operations.
In return the SVLs are designed to withstand the residualvoltage due to current surges and to have the thermalcapability to absorb and dissipate the energy of conductedsurges.
7/28/2019 Cable Sheath Voltage Limiters Presentation
6/8Power System Equipment Solutions to meet your needs
HV Cable Sheath Voltage Limiters
The use of non-combustible materials such as porcelain for postinsulators, polymer for sheath voltage limiters and non-flammableinsulating materials for all component parts incorporated in linkbox.
Suitable rated connections of very low contact resistance toeliminated hot spots and thermal sparking within the link box.
The metallic box and its sealing system are usually designed towithstand an explosive internal pressure of up to 250 kilo Pascals.
The use of high current rated Zinc-Oxide SVL arresters instead ofSilicon Carbide, spark gap or other types of arresters to satisfy themost onerous cable operating conditions.
The Zinc Oxide SVL arresters exhibit far superior electricalcharacteristics and long-term reliability
7/28/2019 Cable Sheath Voltage Limiters Presentation
7/8Power System Equipment Solutions to meet your needs
H.V. Cable Sheath Voltage Limiters
100100100100100kAHigh current 4/10s withstand
10.89.07.25.43.6kVrms20kA 8/20 20 shot duty cycle with
power frequency voltage
applied 1s/shot
2020202020kARated 8/20s current
7.76.45.13.82.5kVrmsMaximum Continuous Operating
Voltage
9.07.56.04.53.0kVrmsRated Voltage
TZS9.0TZS7.5TZS6.0TZS4.5TZS3.0SVL Type
7/28/2019 Cable Sheath Voltage Limiters Presentation
8/8Power System Equipment Solutions to meet your needs
For More Information
To obtain more information please contact our
Office and FactoryAK Power Solutions22 Healey Circuit,
Huntingwood
NSW 2148
Australia
P.O. Box 6907
Blacktown DC
NSW 2148
Phone 61 - 2 - 9676 3500Fax 61 - 2 - 9676 3511
mailto:[email protected]:[email protected]:[email protected]