    Power System Equipment Solutions to meet your needs

    AK Power Solutions

    HV Cable Sheath Voltage

    Limiters

  • 7/28/2019 Cable Sheath Voltage Limiters Presentation

    2/8

    Power System Equipment Solutions to meet your needs

    HV Cable Earthing Link Boxes

    AK Power Solutions has supplied HV CableSheath Earthing Link Boxes since 1989

    Countries that have been supplied include

    Australia, UK,

    Europe,

    Middle East, USA,

    China,

    New Zealand,

    Singapore, Malaysia and

    Indonesia

  • 7/28/2019 Cable Sheath Voltage Limiters Presentation

    3/8

    Power System Equipment Solutions to meet your needs

    H.V. Cable Sheath Voltage Limiters

  • 7/28/2019 Cable Sheath Voltage Limiters Presentation

    4/8Power System Equipment Solutions to meet your needs

    H.V. Cable Sheath

    Voltage Limiters

    Designed, manufactured and tested in Australia by AK Power Solutions

    Used on major cable projects up to 800kV throughout Australia andinternationally

    Highly reliable and effective at managing cable sheath voltage risesand the associated power flows that can result under fault conditions

    Competitively priced providing valuable protection to expensive cableinstallations

    Available in 3.0kV, 4.5 kV, 6.0kV, 7.5kV and 9.00kV voltages othervoltages as required by clients

    Suitable for Indoor or Outdoor Applications

  • 7/28/2019 Cable Sheath Voltage Limiters Presentation

    5/8Power System Equipment Solutions to meet your needs

    HV Cable Sheath Voltage Limiters

    Due to a highly non-linear and non-ohmic current-voltagecharacteristic, the sheath voltage limiters do not conduct anysignificant current during normal and fault-operatingconditions regardless of the magnitude of power frequency

    induced voltages. For this application the function of surge arresters is limited

    only to protect the cable anti-corrosion jacket and bondingsystem against switching and lightning surges to values

    below the breakdown strength of protected elements. As a consequence all elements of the cable bonding system

    must be designed to withstand the induced power frequencyvoltages, both during normal and fault operations.

    In return the SVLs are designed to withstand the residualvoltage due to current surges and to have the thermalcapability to absorb and dissipate the energy of conductedsurges.

  • 7/28/2019 Cable Sheath Voltage Limiters Presentation

    6/8Power System Equipment Solutions to meet your needs

    HV Cable Sheath Voltage Limiters

    The use of non-combustible materials such as porcelain for postinsulators, polymer for sheath voltage limiters and non-flammableinsulating materials for all component parts incorporated in linkbox.

    Suitable rated connections of very low contact resistance toeliminated hot spots and thermal sparking within the link box.

    The metallic box and its sealing system are usually designed towithstand an explosive internal pressure of up to 250 kilo Pascals.

    The use of high current rated Zinc-Oxide SVL arresters instead ofSilicon Carbide, spark gap or other types of arresters to satisfy themost onerous cable operating conditions.

    The Zinc Oxide SVL arresters exhibit far superior electricalcharacteristics and long-term reliability

  • 7/28/2019 Cable Sheath Voltage Limiters Presentation

    7/8Power System Equipment Solutions to meet your needs

    H.V. Cable Sheath Voltage Limiters

    100100100100100kAHigh current 4/10s withstand

    10.89.07.25.43.6kVrms20kA 8/20 20 shot duty cycle with

    power frequency voltage

    applied 1s/shot

    2020202020kARated 8/20s current

    7.76.45.13.82.5kVrmsMaximum Continuous Operating

    Voltage

    9.07.56.04.53.0kVrmsRated Voltage

    TZS9.0TZS7.5TZS6.0TZS4.5TZS3.0SVL Type

  • 7/28/2019 Cable Sheath Voltage Limiters Presentation

    8/8Power System Equipment Solutions to meet your needs

    For More Information

    To obtain more information please contact our

    Office and FactoryAK Power Solutions22 Healey Circuit,

    Huntingwood

    NSW 2148

    Australia

    P.O. Box 6907

    Blacktown DC

    NSW 2148

    Phone 61 - 2 - 9676 3500Fax 61 - 2 - 9676 3511

    [email protected]

    mailto:[email protected]:[email protected]:[email protected]