12
CABLING GUIDE August 2019 www.chiliconpower.com (310) 579-2449 Suggested approaches for common configurations

CABLING GUIDE - uploads-ssl.webflow.com

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CABLING GUIDE - uploads-ssl.webflow.com

CABLING GUIDE

August 2019

www.chiliconpower.com (310) 579-2449

Suggested approaches for common configurations

Page 2: CABLING GUIDE - uploads-ssl.webflow.com

CABLE & ACCESSORIES

• MBC – Modular Branch Cable – Connects each micro to the trunk cable

• MTC – Modular Trunk Cable – 1.025m, 1.7m & 2.15m

• MTC-HR-1.7 – J-Box Pigtail • T6 male and T6 female cap • AC & DC disconnect tools

2

Page 3: CABLING GUIDE - uploads-ssl.webflow.com

MICROINVERTER CONNECTION TO TRUNK CABLE

Trunk Cable MBC Cable

MBC Cable

3

Page 4: CABLING GUIDE - uploads-ssl.webflow.com

LEGEND FOR COMMON CONFIGURATIONS PAGES

4

PART COLOR CODE MBC MTC-1.025 MTC-1.7 MTC-2.15 MTC-HR-1.7 T6 male end cap CP-720 microinverter CP-250E microinverter

Page 5: CABLING GUIDE - uploads-ssl.webflow.com

Module junction box (diodes) DC cables from the module junction box Microinverter cable MBC (one required for each microinverter) Trunk landscape cable MTC-2.15 (N-1) cables required for N microinverters Trunk landscape pigtail MTC- HR-1.7 T6 male cap CP-720 Duo microinverters

C60 OR 72 CELL PORTRAIT-ONE ROW

J BOX

30A Breaker

1 2 3 4 5 6 7

5

Page 6: CABLING GUIDE - uploads-ssl.webflow.com

Module junction box (diodes) DC cables from the module junction box Microinverter cable MBC (one required for each microinverter) Trunk landscape cable MTC-1.025 (N-2) cables required for N microinverters Trunk landscape pigtail MTC- HR-1.7 CP-720 Duo microinverters

C60 OR 72 CELL PORTRAIT-TWO ROWS

30A Breaker

1 2 3 4 5 6 7

6

J BOX

Page 7: CABLING GUIDE - uploads-ssl.webflow.com

60 CELL LANDSCAPE-TWO ROWS

Module junction box (diodes) DC cables from the module junction box Microinverter cable MBC (one required for each microinverter) Trunk landscape cable MTC-1.7 (N-2) cables required for N microinverters Trunk landscape pigtail MTC- HR-1.7 CP-720 Duo microinverters

30A Breaker

J BOX

1 2 3 4 5 6 7 8

7

Page 8: CABLING GUIDE - uploads-ssl.webflow.com

72 CELL LANDSCAPE-TWO ROWS

Module junction box (diodes) DC cables from the module junction box Microinverter cable MBC (one required for each microinverter) Trunk landscape cable MTC-2.15 (N-2) cables required for N microinverters Trunk landscape pigtail MTC- HR-1.7 CP-720 Duo microinverters

30A Breaker

J BOX

1 2 3 4 5 6 7 8

8

Page 9: CABLING GUIDE - uploads-ssl.webflow.com

60 CELL LANDSCAPE-ONE ROW

Module junction box (diodes) DC cables from the module junction box Microinverter cable MBC (one required for each microinverter) Trunk landscape cable MTC-1.7 2(N-1) cables required for N microinverters Trunk landscape pigtail MTC- HR-1.7 T6 male cap (N) caps required for N microinverters CP-720 Duo microinverters

30A Breaker

J BOX

9

1 2 3 4 5 6 7 8

Page 10: CABLING GUIDE - uploads-ssl.webflow.com

72 CELL LANDSCAPE-ONE ROW

Module junction box (diodes) DC cables from the module junction box Microinverter cable MBC (one required for each microinverter) Trunk landscape cable MTC-2.15 2(N-1) cables required for N microinverters Trunk landscape pigtail MTC- HR-1.7 T6 male cap (N) caps required for N microinverters CP-720 Duo microinverters

30A Breaker

J BOX

10

1 2 3 4 5 6 7 8

Page 11: CABLING GUIDE - uploads-ssl.webflow.com

Module junction box (diodes) DC cables from the module junction box Microinverter cable MBC (one required for each microinverter) Trunk landscape cable MTC-2.15 (N-1) cables required for N microinverters Trunk landscape pigtail MTC- HR-1.7 T6 male cap CP-720 Duo microinverters CP-250E Single microinverter

60 OR 72 CELL PORTRAIT-ONE ROW -ODD PANEL COUNT

J BOX

30A Breaker

1 2 3 4 5 6 7

11

Page 12: CABLING GUIDE - uploads-ssl.webflow.com

60 OR 72 CELL - COMPLEX LAYOUT

30A Breaker

12

J-box

For a complex layout, different cable lengths and panel orientations will be required.

Cables required: 10 MBC 4 MTC-1.025 2 MTC-1.7 2 MTC-2.15 1 MTC-HR-1.7 Connected modules

Module orientation

Contact Chilicon Power at (310) 579-2449 if you require assistance.