12
SPREADSHEET INFORMATION Enter data for: Enter data for: Enter dat Surface Casing Depth Required Surface Casing Depth Required g information (size, threads, weigh CBF to the Floor Required Height CBF to the Floor Required Height We Height of the Weld-on Casing Bowl Height of the Screw-on Casing Bowl Flo Landing Joint Length Float Casing Casing Float Length Casing Ta Casing Shoe Length Casing Float Length Casing Size Casing Shoe Length IT WILL CALCULATE ALL TH Casing Tally and Casing Size Casing Tally and IT WILL CALCULATE ALL THE REST. IT WILL CALCULATE ALL THE REST. Weld-On (to 900m or 2950ft) Screw-On (to 900m or 2950ft) Prod Csg (to 3700m or Level to KB or floor if Top Drive al Height of KB (if not top drive) Ground Level to KB or floor if Top Drive Actual Height of KB (if not top drive) choose joints to be left out with joints to be left out with an (*). choose joints to be left out with an (*). spreadsheet remember to enter, first, the units you'll be using: (No Csg Strength Calculations)

Casing Tally

Embed Size (px)

Citation preview

Page 1: Casing Tally

SPREADSHEET INFORMATION

Enter data for: Enter data for: Enter data for:

Surface Casing Depth Required Surface Casing Depth Required Casing information (size, threads, weight etc.)

CBF to the Floor Required Height CBF to the Floor Required Height Well T.D.

Height of the Weld-on Casing Bowl Height of the Screw-on Casing Bowl Float Shoe

Landing Joint Length Float Collar

Casing Jewelry

Casing Float Length Casing Tally and

Casing Shoe Length Casing Float Length

Casing Size Casing Shoe Length IT WILL CALCULATE ALL THE REST.

Casing Tally and Casing Size

Casing Tally and

IT WILL CALCULATE ALL THE REST.

IT WILL CALCULATE ALL THE REST.

Weld-On (to 900m or 2950ft) Screw-On (to 900m or 2950ft) Prod Csg (to 3700m or 12000ft)

Ground Level to KB or floor if Top Drive

Actual Height of KB (if not top drive) Ground Level to KB or floor if Top Drive

Actual Height of KB (if not top drive)

choose joints to be left out with an (*).

choose joints to be left out with an (*).

choose joints to be left out with an (*).

(On every spreadsheet remember to enter, first, the units you'll be using: m or(No Csg Strength Calculations)

Page 2: Casing Tally

LOCATION: ????? RIG: ???? DATE: 99-10-22 ENGINEER: ????

m INPUT OUTPUT Surface Casing Depth Required 345.0 m 346.00 m

5.40 m 346.30 m0.47 m 6.72 m

5.65 m 0.85 m0.42 m Csg Bowl Flange is above GL 0.25 m0.48 m

Casing Size 273.10 mm m0.8

5 ###

m m

6.7

2

5.4

0 m5.6

5

`

mLength * Length * Length * Length *

14.23 10.43 1 10.43 21 14.23 41 56

14.11 14.25 2 14.25 22 14.11 42 57

14.18 14.15 3 14.15 23 14.18 43 58

14.22 12.23 4 12.23 24 14.22 44 59

14.23 14.18 5 14.18 25 14.23 45 60

0.00 14.22 6 14.22 26 14.10 * 46 61

0.00 14.23 7 14.23 27 14.15 * 47 62

0.00 14.10 8 14.10 28 14.17 * 48 63

0.00 14.15 9 14.15 29 14.18 * 49 64

0.00 14.17 10 14.17 30 14.22 * 50 65

13.25 11 13.25 31 51 66

14.22 12 14.22 32 52 67

14.23 13 14.23 33 53 68

12.24 14 12.24 34 54 69

14.21 15 14.21 35 55 70

14.19 16 14.19 36 TOTAL CASING 416.77 m 0.00 0.00

14.09 17 14.09 37 345.95 m14.05 18 14.05 38 0.90 m ###14.25 19 14.25 39 0.85 m ###

14.14 20 14.14 40 345.00 m ###

70.97 274.98 CASING LANDED AT 346.00 mNOTES:

SURFACE CASING & CUT-OFF LENGTHS for TOP DRIVES

UNITS USED:

Surface Casing Landed at Depth of CBF to the Floor Height Required With some Overhole Surface Hole T.D.

Csg Bowl Height (top of Bore to the Flange) Cut off Top Casing Joint at Ground Level to Floor Above Floor Stick Up

Csg Float Collar LengthGuide or Float Shoe Length

SURFACE CASING TALLY in JOINTS WITH AN (*) STAY OUTNo No No No

TOTAL CASING USED Csg FLOAT & SHOE

ABOVE FLOOR STICK-UP

CASING TD REQUIRED

TO

P C

AS

ING

JO

INT

GL

to F

loor

=

Cu

t-O

ff Jt.

=

SU

RFA

CE

CA

SIN

G

CB

F to

the

Flo

or

=

( )

F7
Enter m for metres or ft for feet.
L8
As it is taken from the Well Licence.
L9
Note: To avoid mistakes take into consideration that CBF to the Floor is what it says. It is not CBF to the inside Top of the Sub! Top Drive = no RKB
L10
Height of the Weld-on Csg Bowl as it is measured from the top of the Bore (where the casing will sit) to the flange.
K37
Place asterisks (*) beside the casing joints you wish to leave out. Try different combinations until the desired (or closest to it) casing length is found.
Page 3: Casing Tally

LOCATION: ??? RIG: ?? DATE: 99-10-22 ENGINEER: ???

m INPUT OUTPUT Surface Casing Depth Required 315.0 m 315.05 m

5.40 m 315.60 m0.47 m 0.98 m

Landing Joint Length 6.85 m Csg Bowl Flange is above GL 0.25 m5.65 m0.42 m 0.48 m m

Casing Size 273.10 mm

0.9

8 ###

m m

6.8

5

5.4

0 m5.6

5

`

mLength * Length * Length * Length *

14.23 10.43 1 10.43 21 14.23 41 56

14.11 14.25 2 14.25 22 14.11 42 57

14.18 14.24 3 14.24 23 14.18 43 58

14.22 12.23 4 12.23 24 14.22 44 59

0.00 14.18 5 14.18 25 14.23 * 45 60

0.00 14.22 6 14.22 26 14.10 * 46 61

0.00 14.23 7 14.23 27 14.15 * 47 62

0.00 14.10 8 14.10 28 14.17 * 48 63

14.15 9 14.15 29 49 64

14.17 10 14.17 30 50 65

0.00 11 13.25 * 31 51 66

14.22 12 14.22 32 52 67

14.23 13 14.23 33 53 68

0.00 14 12.24 * 34 54 69

14.21 15 14.21 35 55 70

14.19 16 14.19 36 TOTAL CASING 388.46 m 0.00 0.00

14.09 17 14.09 37 306.32 m14.05 18 14.05 38 0.90 m14.25 19 14.25 39 0.98 m

14.14 20 14.14 40 315.00 m

56.74 249.58 CASING LANDED AT 315.05 mNOTES:

SURFACE CASING & LANDING JOINT LENGTHS for TOP DRIVES

UNITS USED:

Surface Casing Landed at Depth of CBF to the Floor Height Required With some Overhole Surface Hole T.D.

Height of the Screw-on Casing Bowl Above Floor Stick Up

Ground Level to FloorCsg Float Collar Length

Guide or Float Shoe Length

SURFACE CASING TALLY in JOINTS WITH AN (*) STAY OUTNo No No No

TOTAL CASING USED Csg FLOAT & SHOE

ABOVE FLOOR STICK-UP

CASING TD REQUIRED

LAN

DIN

G JO

INT

GL

to F

loor

=

Lan

din

g Jt.

=

SU

RFA

CE

CA

SIN

G

CB

F to

the

Flo

or

=

( )

F7
Enter m for metres or ft for feet.
L8
As it is taken from the Well Licence.
L9
Note: To avoid mistakes take into consideration that CBF to the Floor is what it says. It is not CBF to the inside Top of the Sub! Top Drive = no RKB.
L10
Height of the Screw-on Csg Bowl as it is measured from the bottom first thread to the flange. Please, double check the height of casing bowl you're going to use.
K37
Place asterisks (*) beside the casing joints you wish to leave out. Try different combinations until the desired (or closest to it) casing length is found.
V54
The sum of all Casing Jewelry.
Page 4: Casing Tally

SURFACE CASING & CUT-OFF LENGTHSLOCATION: ???? RIG: ??? DATE: 99-10-22 ENGINEER: ???

m INPUT OUTPUT Surface Casing Depth Required 220.0 m 220.00 m

4.40 m 220.30 m0.42 m 5.89 m

4.80 m 0.77 m0.30 m 4.70 m0.35 m Csg Bowl Flange is above GL 0.10 m0.29 m m m

Casing Size 219.30 mm

0.7

7

1.0

7

0.10

m m

m

5.8

9

4.4

0 m

4.7

0

4.8

0

mLength * Length * Length * Length *

12.25 1 12.25 21 41 56

13.14 2 13.14 22 42 57

13.25 3 13.25 23 43 58

12.98 4 12.98 24 44 59

11.97 5 11.97 25 45 60

13.09 6 13.09 26 46 61

14.02 7 14.02 27 47 62

12.25 8 12.25 28 48 63

14.36 9 14.36 29 49 64

13.25 10 13.25 30 50 65

14.01 11 14.01 31 51 66

13.00 12 13.00 32 52 67

12.27 13 12.27 33 53 68

13.08 14 13.08 34 54 69

12.39 15 12.39 35 55 70

13.29 16 13.29 36 TOTAL CASING 242.39 m 0.00 0.00

0.00 17 11.98 * 37 220.13 m0.00 18 10.28 * 38 0.64 m ###

11.53 19 11.53 39 0.77 m ###20 40 220.00 m ###

0.00 220.13 CASING LANDED AT 220.00 mNOTES:

UNITS USED:

Surface Casing Landed at Depth of CBF to the Floor Required Height With some Overhole Surface Hole T.D.

Height of the Weld-on Casing Bowl Cut off Top Casing Joint at Ground Level to KB Above KB Stick UpActual Height of KB Csg Bowl Flange to KBFloat Collar Length

Casing Shoe Length

SURFACE CASING TALLY in JOINTS WITH AN (*) STAY OUTNo No No No

TOTAL CASING USED Csg FLOAT & SHOE ABOVE KB STICK-UP

CASING TD REQUIRED

TO

P C

AS

ING

JO

INT

GL

to K

B =

CB

F to

KB

=

Cu

t-O

ff Jt.

=

SU

RFA

CE

CA

SIN

G

CB

F to

th

e F

loor

=

( )

F7
Enter m for metres or ft for feet.
L8
As it is taken from the Well Licence.
L9
Note: To avoid mistakes take into consideration that CBF to the Floor is what it says. It is not CBF to the inside Top of the Sub! And also, when casing is being run, usually measurements are made from the floor BECAUSE KB are racked back with the Kelly.
L10
Height of the Weld-on Csg Bowl as it is measured from the top of the Bore (where the casing will sit) to the flange. Please, double check the height of casing bowl you're going to use.
I12
Of the KB themselves. About 0.35m or 1.15ft.
I14
If more casing jewelry is used then enter here the cumulative length.
K37
Place asterisks (*) beside the casing joints you wish to leave out. Try different combinations until the desired (or closest to it) casing length is found.
V54
The sum of all Casing Jewelry.
Page 5: Casing Tally

SURFACE CASING & LANDING JOINT LENGTHSLOCATION: ????? RIG: ??? DATE: 99-10-22 ENGINEER: ????

m INPUT OUTPUT Surface Casing Depth Required 220.0 m 220.02 m

4.70 m 220.50 m0.47 m 0.78 m

Landing Joint Length 6.40 m 5.15 m5.20 m Csg Bowl Flange is above GL 0.05 m0.45 m

0.35 m m m

0.29 m

0.7

8

1.2

3

0.05

Casing Size 219.30 mm

m m

m

6.4

0

4.7

0 m

5.1

5

5.2

0

mLength * Length * Length * Length *

12.25 1 12.25 21 41 56

13.14 2 13.14 22 42 57

13.25 3 13.25 23 43 58

12.98 4 12.98 24 44 59

0.00 5 11.80 * 25 45 60

13.01 6 13.01 26 46 61

10.12 7 10.12 27 47 62

12.39 8 12.39 28 48 63

14.36 9 14.36 29 49 64

13.22 10 13.22 30 50 65

10.01 11 10.01 31 51 66

13.06 12 13.06 32 52 67

0.00 13 12.87 * 33 53 68

13.02 14 13.02 34 54 69

10.82 15 10.82 35 55 70

0.00 16 14.00 * 36 TOTAL CASING 252.43 m 0.00 0.00

13.01 17 13.01 37 213.76 m12.89 18 12.89 38 0.64 m13.12 19 13.12 39 0.78 m

13.11 20 13.11 40 220.00 m

0.00 213.76 CASING LANDED AT 220.02 mNOTES:

UNITS USED:

Surface Casing Landed at Depth of CBF to the Floor Required Height With some Overhole Surface Hole T.D.

Height of the Screw-on Casing Bowl Above KB Stick UpCsg Bowl Flange to KB

Ground Level to KBActual Height of KBCasing Float LengthCasing Shoe Length

SURFACE CASING TALLY in JOINTS WITH AN (*) STAY OUTNo No No No

TOTAL CASING USED Csg FLOAT & SHOE ABOVE KB STICK-UP

CASING TD REQUIRED

LAN

DIN

G

JOIN

T

GL

to K

B =

CB

F to

KB

=

Lan

din

g Jt.

=

SU

RFA

CE

CA

SIN

G

CB

F to

th

e F

loor

=

( )

F7
Enter m for metres or ft for feet.
K8
As it is taken from the Well Licence.
K9
Note: To avoid mistakes take into consideration that CBF to the Floor is what it says. It is not CBF to the inside Top of the Sub! And also, when casing is being run, usually measurements are made from the floor BECAUSE KB are racked back with the Kelly.
K10
Height of the Screw-on Csg Bowl as it is measured from the bottom first thread to the flange. Please, double check the height of casing bowl you're going to use.
I13
Of the KB themselves. About 0.35m or 1.15ft.
I15
If more casing jewelry is used then enter here the cumulative length.
K37
Place asterisks (*) beside the casing joints you wish to leave out. Try different combinations until the desired (or closest to it) casing length is found.
V54
The sum of all Casing Jewelry.
V55
This Above KB Stick-up is effected only by the length of the Landing Joint and by the CBF to KB height. (CBF to KB = CBF to floor + KB actual height)
Page 6: Casing Tally

???? ???? 97-12-22

Joints on Site: 5 SIZE mm THREADS GRADE WEIGHT kg/m

Joints Delivered: 246 139.70 STC & LTC J55 & J80 36.54 & 45.32Joints in Hole: 248 MAKE RANGE WELL T.D. SUPERVISOR

Joints on Racks: 3 Prudential 3 a 3232.50 m ??????

Length * Length * Length * Length * Length * Length * Length *1 13.24 21 13.23 41 13.23 61 13.23 81 13.23 101 12.50 121 11.902 13.23 22 13.22 42 13.22 62 13.22 82 13.22 102 12.57 122 13.223 13.24 23 13.25 43 13.25 63 13.25 83 13.25 103 13.24 123 13.254 13.23 24 11.76 44 11.76 64 11.76 84 11.76 104 13.23 124 11.765 13.23 25 13.24 45 13.24 65 13.24 85 13.24 105 13.23 125 13.246 13.13 26 12.14 46 12.14 66 12.14 86 12.14 106 13.13 126 12.147 13.22 27 13.14 47 13.14 67 13.14 87 13.14 107 13.22 127 13.148 13.30 28 13.24 48 13.24 68 13.24 88 13.24 108 13.30 128 13.249 13.21 29 13.23 49 13.23 69 13.23 89 13.23 109 13.21 129 13.23

10 13.21 30 11.33 50 11.33 70 11.33 90 11.33 110 13.21 130 11.3311 13.55 31 13.23 51 13.23 71 13.23 91 13.23 111 13.55 131 13.2312 13.24 32 13.13 52 13.13 72 13.13 92 13.13 112 13.24 132 13.1313 13.23 33 13.13 53 13.13 73 13.13 93 13.13 113 13.23 133 13.1314 13.23 34 13.21 54 13.21 74 13.21 94 13.21 114 13.23 134 13.2115 13.24 35 13.23 55 13.23 75 13.23 95 13.23 115 13.24 135 13.2316 13.15 36 13.22 56 13.22 76 13.22 96 13.22 116 13.15 136 13.2217 13.14 37 13.23 57 13.23 77 13.23 97 13.23 117 13.14 137 13.2318 13.24 38 13.23 58 13.23 78 13.23 98 13.23 118 13.24 138 13.2319 13.23 39 13.17 59 13.17 79 13.17 99 13.17 119 13.23 139 13.1720 11.75 40 13.23 60 13.23 80 13.23 100 13.23 120 11.75 140 13.23

263.24 Total 259.79 Total 259.79 Total 259.79 Total 259.79 Total 261.84 Total 258.46Length * Length * Length * Length * Length * Length * Length *

141 13.24 161 13.23 181 12.50 201 11.76 221 11.76 * 241 12.57 261

142 13.23 162 13.22 182 12.57 202 13.24 222 13.24 242 13.24 262

143 13.23 163 13.25 183 13.24 203 12.14 223 12.14 243 13.23 263

144 13.16 164 11.76 184 13.23 204 13.14 224 13.14 244 13.23 264

145 12.35 165 13.24 185 13.23 205 13.24 225 13.24 245 13.13 265

146 11.98 166 12.14 186 13.13 206 12.23 226 13.23 246 13.22 266

147 13.24 167 13.14 187 13.22 207 11.33 * 227 11.33 247 13.30 267

148 13.24 168 13.24 188 13.30 208 13.21 228 13.23 248 13.21 268

149 13.14 169 13.23 189 13.21 209 13.23 229 13.13 249 13.21 * 269

150 13.15 170 11.80 190 13.21 210 13.22 230 13.13 250 13.55 270

151 13.25 171 13.23 191 13.55 211 13.25 231 13.21 251 13.24 271

152 13.22 172 13.13 192 13.24 212 11.76 232 13.23 252 272

153 13.23 173 13.13 193 13.23 213 13.24 233 13.22 253 273

154 13.24 174 13.21 194 13.23 214 12.14 234 13.23 254 274

155 13.24 175 13.23 195 13.24 215 13.14 235 13.23 255 275

156 13.23 176 13.22 196 13.15 216 13.24 236 13.17 256 276

157 13.23 177 13.23 197 13.14 217 13.23 237 14.17 257 277

158 13.23 178 13.23 198 13.24 218 13.24 238 13.65 258 278

159 13.23 179 13.17 199 13.23 219 12.14 239 13.22 259 279

160 13.20 180 13.23 200 11.75 220 13.14 240 13.25 260 280

262.26 Total 260.26 Total 261.84 Total 243.93 Total 249.39 Total 131.92 Total 0.00

TALLY SUMMARY m jts CASING STRING3268.60 251 0.43 m 3232.50 m3232.30 248 0.51 m 3233.24 m

36.30 3 m 1.24 mm 3232.00 m

0.00

PRODUCTION CASING LOCATION: RIG: DATE:

No No No No No No No

No No No No No No No

CASING DETAILS INPUT Notes:Total Casing: Float Shoe: Well T.D.: The first 46 and

the last 2 joints are of heavier Wt. & stay on the string.

Casing Used: Float Collar: Total Csg String:Casing Left Out: Other Jewelry: Casing Above KB:

Note: Joints with an (*) stay out. More Jewelry: Casing Landed at:

C8
This value counts all joints to be left out and marked with an asterisk. And Joints on Site + Joints Delivered = Joints in Hole + Joints on Racks
S8
To complete the CASING STRING (see below) calculations yourself and by hand (after printing the page!), enter here an m or, an a if you want these calculations to be done automatically while you choose, with an asterisk (*), which joints stay out.
T8
If possible, always drill 0.30m (1.0ft) or more of overhole.
W8
Enter m or ft.
L55
Enter string Marker Joints lengths on the table above in the order required.
AB55
Below enter your notes.