CEA7Automatic Mains Failure controller. AMF
A
ELECTRONICS publication 10_08
A
When an alarm or warning is detected, the controller produces an acoustic alarm, at the same time the digital alarm output (AL) activates and the LED ofRESET button flashes. This status will remain the same as long as the failure condition continues for a programmable period of time.
ALARMS
Automatic mains failure controller
CEA7
exchance for new configurations
CEM7 CEC7
ENGINE alarms
•Highwatertemperature.•Lowoilpressure.•Batterychargeralternator.•StartFailure.•Lowcoolantlevel.•Fuelstorage.•Overspeed.•Underspeed.•Batterylowvoltage.•Highcoolanttemperaturebysensor.•Lowoilpressurebysensor.•Lowfuellevelbysensor.•Unexpectedshutdown.•StopFailure.•LowEnginetemperature.•GensetvoltageDroop.•Emergencystop.•Gensetcontactorswitchingfailure.
GENERATOR alarms•Overload.•Gensetvoltageasymmetry.•Maximumgensetvoltage.•Minimumgensetvoltage.•MaximumgensetFrequency.•MinimumgensetFrequency.•Erroneousphasesequenceofthegenset.•Inversepower.•Shortcircuit.
MAINS alarms•MaximumMainsVoltage.•MinimumMainsVoltage.•MaximumMainsFrequency.•MinimumMainsFrequency.•Mainsphasesequencefailure.•Mainspowerfailure.•Mainscontactorswitchingfailure.
(3 programmable alarms)
www.himoinsa.com
ELECTRONICS
1. VISUALIZATION MODULE•Backlit graphic display of 128 x 64.•14 BUTTONS.
Only Push Buttons: 4pushbuttonsforMENUandprogramming:UP,DOWN,CANCEL/BACKandENTER.2contactorcontrolpushbuttons:GENSETandMAINS.PushButtonwithLED:4controlpushbuttons:GENSET:START,STOP,RESETyFuelTransference.4modepushbuttons:AUTO,MAN,TESTyLOCKED.
LEDs for alarms and genset status.
Engine status LEDs:•EngineStarted.•Pre-heating.•EngineStart.•Batterychargeralternator.
Alarm LEDs:
•Fuelstorage.•Batterylevels.•Hightemperature.•StartFailure.•Overspeed.•LowOilPressure.•AUX1(Freetoprogramme).•AUX2(Freetoprogramme).
Electric power status LEDs:•Mainspowerstatus.•EngineStatus.•Gensetpowersupplystatus.
Contactors status LEDs:•Mainscontactoractive.•Gensetcontactoractive.
Multi-languagues.
GENERAL DESCRIPTION
CEA7 controller is a supervision equipment for mains signal and also a supervision and electrical supply through the genset. This controller is composed by 2 different modules:
1. VISUALIZATION module2.MEASUREMENTS module
VISUALIZATION MODULE Thevisualizationmoduleprovidesinformationaboutthestatusofthedeviceand,atthesametime,allowstheusertointeractwithit.Withthisvisualizationmoduletheuserisabletocontrol,programandconfigurethefunctionsoftheunit.
MEASUREMENTS MODULE Themeasurementsmodulecontrolsandmonitorsthecontrolboard.Itislocatedintherearpartofthepanel,inordertoreducethewiringandtoavoidelectromagneticdisturbances.Everysignal,sensorandactuatorisconnectedtothismodule.
ConnectionbetweenthemeasuremoduleandvisualizationmodeismadebymeansofaCAN BUS(CommunicationBus).Thisproducesaninterconnectionbetweenaddi-tionalmoduleswhichguaranteestheproperworkingofthecontroller.
CEA7visualizationmodule
Automatic mains failure controller
CEA7
ELECTRONICS publication 10_08
2. MEASUREMENTS MODULEThe measurements module provides the following readings of the electric mains supply:
•Phasetoneutralvoltage.•Phasetophasevoltage.•PhaseAmperage.•Frequency.•Real,apparentandreactivepowers.•Powerfactorandcosphî.•Instantpower(KwH)andhistoricalpower(day,month,year).
Engine features:Engine alarm inputs:•Fuelreserve.•Oilpressure.•Coolanttemperature.•Coolantlevel.•Emergencystop.(stopbutton).
Analogic engine inputs:•Fuellevel.•OilPressure.•CoolantTemperature.•Configurableinput(i.e.Oiltemperature).•Batterychargealternatorvoltage.
Configurable inputs; the measurements device has 5 inputs that can be programmed to carry on the following functions:•Mainscontactorconfirmation.•Gensetcontactorconfirmation.•Ratechangenotice.•Ratechange.•Startdisabling.•Externalstart.•Test.•Manualoverride.•3programmablealarms.Engine statistics:•Numberofworkinghours.•Numberofstarts.
PHGmeasurementsmodule
Automatic mains failure controller
CEA7
Controls Engine’s Functions:•Pre-heatingorGlowPlug.•Stop.•Start.•Coolantheater.•FuelTransferpump.•Alternatorexcitation.
The measurements module has outputs which allow monitoring of the operative conditions of the controller:•Enginerunning(on).•Controlboardalarm.•3programmableoutputswhichmonitorthecontrolboardalarmconditionsortheinputsabouttheengi-nedata.
CEA7 Controller has also 3 relay outputs incorporated: •MainscontactorOutput.•GensetContactorOutput.•FuelPump/WaterheatingOutput.
www.himoinsa.com
ELECTRONICS
•InterfaceCAN/USB.Allowscommunicationwiththecontrolpanelinlocalmodemakingeasierparameterprogramming,alarmconfiguration,programmableinputs/outputs.•InterfaceCAN/RS232AllowsremotecommunicationwiththecontrolpanelthroughananalogicmodemoraGSMmodem.•PositioningsystemGPS.AllowsthroughtheinterfaceCAN/RS232tofindtheexactpositionofthegenset.•InterfaceCAN/AllowscommunicationwiththecontrolpanelwithsystemsworkingwithprotocolMODBUS.•InterfaceCAN/LANofferstheoptiontoconnecttheCEA7controlpaneltoanEthernetnet.•InterfaceCAN/J1939allowsmonitoringofengineswhicharecompatibletothisprotocol.•EJPFunctions(StandardforFrenchmarket)•EJP/TFunctions(forFrenchmarket)•SRCFunctions(GensetstartandchangeoverevenwithMainspresencethroughanexternalsignal)•Preheatingfunctionsofthesparkplugs.•KeyboardblockFunctions.•DecantingFuelPumpFunctionscommand.•Remotemonitoringfunctionsforcontrolpanelstatus(i.e.ResetstatusorAutomaticStatus,etc..)•Possibilitytoblockallthefunctionsafterapredefinednumberofworkinghours,maintenanceorrent.•Automatictestweeklyordaily.•ExternalstartandStop•Threeprogrammablealarmsfordifferentuseddefinedbytheuser.
VARIOUS FUNCTIONS
•Workingtemperature:min-20ºCmax80ºC.•Voltagesupply:min.8Vmax.30V.•Maximumamperageconsumewhenrest:100mA.•Startingoutputamperage:70Aintransitoryregime,40Aduringonesecond.20Ainregimeofstationarywork.•Outputamperagewhenenginestop:(exc./des).70Aintransitoryregime,40Aduringonesecond.20Ainregimeofstationarywork.•Pre-heatingoutputamperage:70Aintransitoryregime,40Aduringonesecond.20Ainregimeofstationarywork.•Alarmcontactamperage,Engineworking1A.•Genset/Mainscontactorsmax.amperage8A.•Gensetfrequencystatus:30-80hz.•Pick-upfrequencystatus:100Hzat8Khz.•Fuellevelresistance:330Ohms.•MeasureAccuracy:1%.•Protectionrank:IP65(oncontrolpanel).
PossibilityofinstallingtheSecondZeroSuppres-sionexpansionisanelectronicmodulewhosefunctionistoavoidthesecondzerothatisprodu-cedintheswitchingwhenthepowerreturnsandthegeneratorgroupdisconnects.
MAIN CONSTRUCTIVE DATA
Automatic mains failure controller
CEA7
ELECTRONICS publication 10_08
DIMENSIONS AND MECHANIZING
VisualizationmoduleCEA7
Maximum dimensions:210x160x35,5mmWeight:437g
Maximum dimensions:202x117x36mmWeight:324g
Automatic mains failure controller
CEA7
MeasurementsmodulePHG
www.himoinsa.com
ELECTRONICS
Quick controllers list
• Standardx Notincluded• Optional
GENERATOR READINGSVoltageamongphasesVoltageamongphasesandneutralAmperageFrequencyApparentpower(kVA)Activepower(kW)Reactivepower(kVAr)Powerfactor
MAINS READINGSVoltageamongphasesVoltageamongphaseandneutralAmperageFrequencyApparentpowerActivepowerReactivepowerPowerfactor
ENGINE READINGSCoolanttemperatureOilpressureFuellevel(%)BatteryvoltageR.P.M.Batterychargealternatorvoltage
ENGINE PROTECTIONSHighwatertemperatureHighcoolanttemperaturebysensorLowenginetemperaturebysensorLowoilpressureLowoilpressurebysensorLowcoolantlevelUnexpectedshutdownFuelstorageFuelstoragebysensorStopfailureBatteryvoltagefailureBatterychargealternatorfailureOverspeedUnderspeedStartfailureEmergencyStop
ALTERNATOR PROTECTIONSHighfrequencyLowfrequencyHighvoltageLowvoltageOveramperageShort-circuitAsymmetryamongphasesIncorrectphasesequenceInversepowerOverloadGensetsignaldroop
COUNTERSTotalhourcounterPartialhourcounterKilowatimeterStartsvalidcountersStartsfailurecountersMaintenance
CEC7 CEA7CEM7M6xxxxxxxx
xxxxxxxx
xxxxxx
PxxPxx•AxxxAPX••
Pxxxxxxxxxx
xxxxxx
••••••••
xxxxxxxx
•(1)
•(1)
••••
P(2)
A(3)
A(5)
P(2)
A(3)
P•A
A(3)
•AAPP••
PPPPPPPPPPx
••••••
••••••••
••••xxxx
xxxxxx
xxxxxxxxxxxxxxx•
P(6)
P(6)
P(6)
P(6)
xx
P(6)
P(6)
xxP
••••••
••••••••
••••••••
•(1)
•(1)
••••
P(2)
A(3)
A(5)
P(2)
A(3)
P•A
A(3)
•AAPP••
PPPPPPPPPPx
••••••
NOTE: All the protection are programmable to carry out “warning” or “engine stop with or without cooling”.
www.himoinsa.com
ELECTRONICS publication 10_08
Available Software:
Configuration
Monitoring
Fleet management
COMMUNICATIONSRS232RS485J1939ModbusModbusIPCCLANSoftwareforPCAnalogicmodemGSM/GPRSmodemRemotescreenTelesignal
FEATURESAlarmshistoryExternalstartStartinhibitionMainsfailurestartStartundernormativeEJPKeystartPre-heatingenginecontrolGensetcontactoractivationMain&GensetcontactoractivationFueltransfercontrolEnginetemperaturecontrolManualoverrideProgrammablealarmsGensetstartfunctionintestmodeProgrammableoutputsMagneticPick-upcontrolMultilingual
SPECIAL FUNCTIONSPositioningGPSSynchronizationwithmainsMainsSynchronismSecondZeroSuppressorRAM7RemotescreenTimer
CEC7 CEA7CEM7M6
Note: AS5 + CC2 configu-ration, will have all CEM7 functionality plus CEC7 mains readings.
xxxxxxxxxx
•xxxx••xxx
x
xxxxxxx
••••••
•(4)
•••
•(8+4)
(10)/(• +100)••
• (CEC7)•x••x••••••••
••(MPS5.0)•(MPS5.0)• (+CEC7)
•••
••x••x
• (4)
••x
(10)•••xxxx•xxxxxxx•
•••••••
••••••
• (4)
•••
• (8+4)
(10)/(• +100)••••x•x•••••••••
••(MPS5.0)•(MPS5.0)
••••
PANEL MODELM6M5AS5
AS5
AS5+CC2
AC5
Quick control panel list
FUNCTIONALITYAuto-start(KeyStart)Auto-startAutomaticControlPanelWithoutmainscontrolAutomaticControlPanelWithMainsControl(customerchangeovercontactors)AutomaticControlPanelWithMainsControl(Himoinsachangeovercontactorwithdisplay)AutomáticMainsFailure(wallmountedpanel)
CONTROLLER MODELM6CEM7CEM7**
CEA7
CEM7+CEC7
CEA7
**Pre-heating resistance in the Genset and Battery charger in the control panel included.
M6 CEM7 CEC7 CEA7
A:Warning.WarningalarmwithoutenginestopP:AlarmwithEngineStop(1)Bulbsinstallationnecessary.(2)Shotprotection.(3)Programmableanalog.protection.(Dependsonbulbinstallations)(4)Standardwhenoptionalofcommunicationisincluded.(5)Changeoveractivationnotallowedbeforereachingatthetemperaturelevelprogammed.(6)OnlyprotectionwithconnectiontoCEM7.
CEC7:availablewhenthecontrollerCEC7isincorporatedtotheinstallation.MPS 5.0:availableapplicationwhenthemoduleMPS5.0hasbeenincorporatedtothepanel.
www.himoinsa.com
ELECTRONICS
HIGH PROTECTIONProtectionfortheGenset,aswellasthedifferentinstrumentsanddevicesconnectedtothegenset.Protectionfor:Overvoltage,Undervoltage,Asymmetry,Overamperage,Overfrequence,underfrequence,Overload,Incorrectgensetphasesequence,inversepower,Shortcircuit,Highcoolanttemperature,LowOilPressure,Overspeed,Underspeed,BatterychargerFailure,Fuelreserve,Lowcoolantlevel,gensetdroop,maximumandminimummainsvoltagefailure,max.andmin.mainsfrequenciesfailure,mainssequencefailure,droopmainssignalfailure,mains&gensetchangeoverfailure,etc.
COMPLETE HANDFUL OF MEASURESAllowsthereadingofahandfulofmeasureswithnoneedofadditionalinstrumentsorexternalgauges.Apartfromprotection,offerscontinuouslytheparametersofgensetworksandthedigitalreadingsfor:Voltage,amperage,frequency,FuelLevel,tachometer(hourcounter)powerconsumption,batteryalternatorvoltage,batteryvoltage,enginetemperature*,oilpressure*,Currentpowermeasures,cosineofphiperphase,readingandsituationoftheprogrammableinputs,Totalenergyconsumptionmeasures(day,monthandyear**),Alarmcontrol.
GREAT VERSATILITYThesemodulesystemsallowtheadaptationandgrowingwiththemarketdemandandthelawrequirements.Themodularityallowstohaveasharpgrowthandall-purposecomponents(evenwithdifferenttypesofengines).Dependsoftheplatelocationispossibletoobtaindifferentconfigurations.Westartfromastandarddesignandaccordingtotheneedsitispossibleto
developnewextensions.Installonlythenecessaryelements.Basisstockreduction.Thesamecontrolpanelfordifferentvoltage.ElectricalSupplyvoltage:12/24V.
SIMPLEInstallationisreallysimple.Wiringsystemisshortened.Easytoturnamanualdevicesystemintoautomaticandviceversa.Withonesimpleprogrammingofthecontrolpanelyoucanadjustmeasuresandlevels(i.e.automaticfillingofthefueltank).Poweroutputsremainprotected.Morethan64nodesandmorethan1.000meterswithoutsignalrepeater.
FAST PROGRAMMINGPossibilitytopersonalizethefeaturesofthecontrolpaneltoyourownapplication.Apartfromprogrammingmeasureparameters,thresholds,times,alarms,regulations,etc,youcanalsoprogramthecontrolpaneltostopthegenset(withorwithoutcoolingtime)osimplygiveyouawarningwithnostopoftheengine.
DIFFERENT STARTING MODEManualStart,AutomaticStart,Mainsfailure,orfreevoltagecontact.
NEW BUSINESS LINESThiscontrolpanelallowsthecreationofnewbusinesslinesanddifferentmanagingpossibilitiessinceitcontains:
•Preventivemaintenance.•Fungible.•Routesgeneration.•GensetGlobalpositioning.•Remotecontrol.•Antitheftfollowup.•Protection/security.
* Only with the corresponding sensors installed ** Only with programming timer.
ADVANTAGES
english frenchspanish german italian portuguese polish russian chinese
www.himoinsa.com
HIMOINSA CENTRAL_HEAD OFFICE
HIMOINSA S.LCtra.Murcia-SanJavier,km23.630730SanJavier(MURCIA)SPAIN
TLF. +34 968 19 11 28 / +34 902 19 11 28FAX+34968191217
EXPORTFAX+34968190420/[email protected]
HIMOINSACENTRO(Madrid)TLF.+34916842106FAX+34916842107
CentrodeDistribuciónRecambiosSparePartsDistributionCentre
TLF.+34968334015FAX+34968191153
FILIALES_ SUBSIDARIES
EUROPA / EUROPEHIMOINSAFRANCE(GENELECS.A.S.)
TLF.+33474626505FAX:+33474090728
HIMOINSAITALIAS.R.L.TLF.+390444580922FAX:+3904441833308
HIMOINSAPORTUGALLDATLF.+351214266550FAX:+351214266569
HIMOINSAPOLSKASP.ZO.OTLF.+48228681918FAX:+48228681931
HIMOINSADEUTSCHLANDTLF.+4993729495447FAX:+49600962108
ASIA - PACÍFICO / PACIFIC - ASIAHIMOINSACHINACO.LTD
TLF.+8651986226688FAX:+8651986226687
HIMOINSAFAREASTPTELTDTLF.+6562651011FAX:+6562651141
HIMOINSACENTRALASIA(KAZAKHSTAN)TLF/FAX:+77273923688
ORIENTE MEDIO / MIDDLE EASTHIMOINSAMIDDLEEASTFZE
TLF.+97148873315FAX:+97148873318
AMERICAHIMOINSAMEXICO
TLF.+52(33)36758646FAX:+52(33)39142590
HIMOINSAPOWERSYSTEMS,INC.(USA)TLF.+19134955557FAX:+19134955575
HIMOINSAPTY(PANAMA)TLF.+5072325741FAX:+5072326459
HIMOINSALATINOAMERICA(Rep.Argentina)TLF.+542320401900/1901