35
Catalog August 2015 Zelio Timer Relays

Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

Embed Size (px)

Citation preview

Page 1: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

Catalog

August 2015

Zelio Timer Relays

Page 2: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

Digi-Cat, a handy USB key for PC

Contact your local representative to get your own Digi-Cat

How can you fit a 6000-page catalog in your pocket ?Schneider Electric provides you with the complete set of industrial automation catalogs all on a handy USB key for PC or in an application for tablets

e-Library, the app for tablets

> Convenient to carry > Always up-to-date > Environmentally friendly > Easy-to-share format

> Go to the App Store and search for e-Library > or scan the QR code

If you have an iPad®:

> Go to the Google Play StoreTM and search for eLibrary > or scan the QR code

If you have an Android tablet:

Page 3: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

Zelio Timer RelaysContent

Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2

b Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4

b Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4

b Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 6

b Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 9

b Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 20

v Modular relays with solid state or relay output, width 17 .5 mm/0.689 in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 20

v Modular single, dual or multifunction relays, relay output with diagnostic button and dial pointer, width 22 .5 mm/0.886 in. . . . . . . . . . . page 21

v Modular single, dual or multifunction relays, relay output, width 22 .5 mm/0.886 in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22

v Industrial single, dual or multifunction relays, relay output, width 22 .5 mm/0.886 in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 23

v Industrial single function relays, optimum, relay output, width 22 .5 mm/0.886 in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 25

v Industrial single or multifunction relays, solid state output, width 22 .5 mm/0.886 in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 26

v Miniature plug-in relays, relay output . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 27

v Analog, electronic relays, relay output, 48 x 48 . . . . . . . . . . . . . . . . . . . . .page 28

v Universal plug-in relays, 11-pin, relay output, width 35 mm/1.377 in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 29

v Universal plug-in relays, 8-pin, relay output, width 35 mm/1.377 in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 30

v Panel-mounted universal, plug-in relays, relay output . . . . . . . . . . . . . . .page 31

b Product reference index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 32

1

Page 4: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

32

Applications These timing relays enable simple automation cycles to be set up using wired logic. They can also be used to complement the functions of PLCs.

These timing relays enable simple automation cycles to be set up using wired logic. They can also be used to complement the functions of PLCs.

Output Solid state Timing relays with solid state output reduce the amount of wiring required (wired in series). The durability of these timing relays is independent of the number of operating cycles.

Relay Relay outputs provide complete isolation between the supply circuit and the output. It is possible to have several output circuits.

Relay Relay outputs provide complete isolation between the supply circuit and the output. It is possible to have several output circuits.

Type Modular Industrial Modular Modular Industrial Industrial Plug-in Panel-mounted/plug-in

Universal Miniature Analogue Digital

Time ranges v 7 ranges:1 s,10 s,1 min,10 min,1 h,10 h,100 h

v 1 or 2 ranges depending on model:10 s,30 s,300 s,60 min

Depending on model:v 6 ranges 1 s,10 s,1 min,10 min,1 h,10 hv 7 ranges:1 s,10 s,1 min,10 min,1 h,10 h,100 h

Depending on model:v 7 ranges:1 s,10 s,1 min,10 min,1 h,10 h,100 hv 7 ranges:1 s,3 s,10 s,30 s,100 s,300 s,10 min v 7 ranges0 .5 s1 s3 s10 s30 s100 s300 sv 1 range30 sv 10 ranges:1 s,3 s,10 s,30 s,100 s,300 s,30 min,300 min,30 h,300 h

Depending on model:v 7 ranges:1 s,3 s,10 s,30 s,100 s,300 s,10 minv 10 ranges1 s,3 s,10 s,30 s,100 s,300 s,30 min,300 min,30 h,300 h

v 1 range depending on model:0.5 s,3 s,10 s,30 s,300 s,30 min

v 7 ranges:1 s, 10 s,1 min,10 min,1 h,10 h,100 h

v 7 ranges:0 .1 s . . .1 s,1 s . . .10 s,0 .1 min . . .1 min,1 min . . .10 min,0 .1 h . . .1 h,1 h . . .10 h,10 h . . .100 h

14 ranges:1 .2 s,3 s,12 s,30 s,120 s,300 s,12 min,30 min,120 min,300 min,12 h,30 h,120 h,300 h

Depending on model:v 7 ranges:99 .99 s,999 .99 s,99 min 59 s,99 .99 min,999 .9 min,99 h 59 min,999 .9 h

v 11 ranges:99 .99 s,999 .99 s,9999 s,99 min 59 s,99 .99 min,999 .9 min,9999 min,99 h 59 min,99 .99 h,999 .9 h,9999 h

Timer Relay type RE17L RE9 RE17R RE22 RE7 RE8 RE88867 REXL RE48A RE88857

Pages 16 17 16 18 19 20 21 and 22 23 24 25

Zelio Timer RelaysSelection guide

8 .0

Page 5: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

4

Presentation

Presentation A timing relay is a component which is designed to time events in industrial automation systems by closing or opening contacts before, during or after a set timing period .

There are three main families of timing relays: b DIN rail mounted relays (RE7, RE8, RE9, RE17, RE22, REXL…) designed for mounting on DIN rails in an enclosure .b Miniature plug-in relays (REXL) designed to be plugged into sockets .b Panel mounted/plug-in relays RE48A designed for mounting on the panel front to give users easy access to the settings .

These relays have one, two or four outputs . Sometimes the second output can be either timed or instantaneous . If the power is switched off during the timing period, the relay reverts to its initial position .

Application examples:b opening of automatic doorsb alarmb lighting in toiletsb car park barriers, etc

Definitions The following definitions explain the operation of the relays: b Relay output: This is the most common type of output . When the relay is energized, the moving armature is attracted by the coil and so actuates the contacts, which change state . When the relay is de-energized, both the armature and the contacts revert to their initial position .This type of output allows complete isolation between the supply and the output . There are three types of output contacts: C/O: changeover contact, i .e . when the relay is de-energized, the circuit between the common point C and N/C is closed and when the relay is operating (coil energized), it closes the circuit between the common point C and N/O .

CNC

NO

N/C: a contact that is closed without being actuated is called a Normally Closed (N/C) contact .

NC

N/O: a contact that closes when actuated is called a Normally Open (N/O) contact .

NO

b Solid state output: This output is entirely electronic and involve no moving parts; service life is therefore increased .

b Breaking capacity: The current value that a contact is capable of breaking in specified conditions.

b Mechanical durability: The number of mechanical operating cycles of the contact or contacts .

b Minimum switching capacity (or minimum breaking capacity): This is the minimum required current which can flow through the contacts of a relay.

b G (Gate) input: Gate input allows timing in progress to be interrupted without it being reset .

Zelio Timer Relays

DIN rail mounted timer relays

Miniature plug-in timer relays with sockets

Panel-mounted/plug-in timer relays

RE48A

5 .0

RE22RE17

REXL

+

RXZE2M114

Page 6: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

5

Presentation (continued)

Definitions (continued)Functions

Timing functions are identified by letters. For the complementary functions, select the main timing function using the selection dial in the front panel; refer to functional diagrams for connection .

Main timing functions

Complementary functions (1) Definitions

A (2) Power On-delay relay

Ac On-delay and off-delay relay with control signal

Ad Pulse delayed relay with control signal

Ah Pulse delayed relay (single cycle) with control signal

Ak Asymmetrical on-delay and off-delay with control signal

At Power on-delay relay with pause/summation control signal

Aw Power on-delay with retrigger/restart control

B (2) Interval relay with control signal

Bw Double interval relay with control signal

C (2) Off-delay relay with control signal

Ct Off-delay relay with control signal and with pause/summation control

D (2) Symmetrical flashing relay (starting pulse-off)

Di (2) Symmetrical flashing relay (starting pulse-on)

Dt Symmetrical flashing relay (starting pulse-off) with pause/summation control signal

Dw Symmetrical flashing relay (starting pulse-off) with retrigger/restart control signal

H (2) Interval relay

He Pulse-on de-energization

Ht Interval relay with pause/summation control signal

Hw Ineterval relay with retrigger/restart control signal

K Delay on de-energization (without auxiliary supply)

L (2) Asymmetrical flashing relay (starting pulse-off)

Li (2) Asymmetrical flashing relay (starting pulse-on)

Lt Asymmetrical flashing relay with pause/summation control

N Safe guard relay

O Delayed safe guard relay

P Pulse delayed relay with fixed pulse length

Pt Pulse delayed relay with fixed pulse length and pause/summation control signal

Q Star-delta relay (2 N/O with same common)

Qc Star-delta timing (1 C/O)

Qe Star-delta timing (1 N/C + 1 N/O with split common)

Qg Star-delta timing (2 C/O with same common)

Qt Star-delta timing (2 C/O output with split common)

T Tl Bi-stable relay with control signal on

Tt Retriggerable bi-stable relay with control signal on

W Interval relay with control signal off

Wt Interval relay with control signal off and with pause/summation control

(1) Complementary functions enhance the main timing functions. Example: Ac: timing after closing and opening of control contact.

(2) The most commonly used timing functions.

Zelio Timer Relays

Page 7: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

6

Selection

Selection tableSelection criteriab Functions (On-delay or off-delay, counter, flashing, …)b Supply voltage (example: z 12 V…240 V)b Timing range for a timing relay (example: 0 .05 s…100 h)b Type of output (contact or solid state) and required Number of contactsb Breaking capacity or Rated current of contacts, expressed in Amperes. This is the maximum current which may flow through the contacts.

Functions Timing range

Supply voltage

Type of output

Rated current

Relay

A 0 .1 s…100 h c 12 V 2 C/O contacts 5 A REXL2TMJD4 C/O contacts 3 A REXL4TMJD

0 .1 s…100 h c 24 V 2 C/O contacts 5 A REXL2TMBD4 C/O contacts 3 A REXL4TMBD

0 .1 s…100 h a 24 V 2 C/O contacts 5 A REXL2TMB74 C/O contacts 3 A REXL4TMB7

0 .1 s…100 h a 120 V 2 C/O contacts 5 A REXL2TMF74 C/O contacts 3 A REXL4TMF7

0 .1 s…100 h a 230 V 2 C/O contacts 5 A REXL2TMP74 C/O contacts 3 A REXL4TMP7

0 .1 s…10 s z 24…240 V 1 solid state output 0 .7 A RE9TA11MW0 .3 s…30 s 0 .7 A RE9TA31MW3 s…300 s 0 .7 A RE9TA21MW40 s…60 min 0 .7 A RE9TA51MW0 .1 s…100 h 0 .7 A RE17LAMW0 .02 s…300 h 2 timed C/O contacts 5 A RE48ATM12MW

0 .05 s…300 h z 24 V, a 110…240 V 1 C/O contact 8 A RE7TL11BU0 .1 s…3 s 8 A RE8TA61BUTQ0 .1s…10 s 8 A RE8TA11BUTQ0 .3 s…30 s 8 A RE8TA31BUTQ3 s…300 s 8 A RE8TA21BUTQ20…30 min 8 A RE8TA41BUTQ0 .05 s…300 h z 24 V, a 110…240 V,

z 42…48 V2 C/O contacts 8 A RE7TP13BU

A, Ac, At, B, Bw, C, D, Di, H, Ht 0 .1 s…100 h a 24…240 V 1 solid state output 0 .7 A RE17LMBM0 .1 s…100 h z 12 V 1 C/O contact 8 A RE17RMJU0 .1 s…100 h z 12…240 V 1 C/O contact 8 A RE17RMMW

8 A RE17RMMWS0 .1 s…100 h c 24 V, a 24…240 V 1 C/O contact 8 A RE17RMMU0 .1 s…100 h c 24/a 24…240 V

z 12 Vz 12…240 V

2 C/O contact 8 A RE22R2MMURE22R2MJURE22R2MMW

A, At 0 .1 s…100 h c 24 V, a 24…240 V 1 C/O contact 8 A RE17RAMU

0 .1 s…100 h c 24 V, a 24…240 V 2 C/O contact 8 A RE22R2AMU

A, Aw 0 .05 s…300 h z 24…240 V 1 C/O contact2 C/O contacts

8 A RE22R1AMRRE22R2AMR

A, At, Aw 0 .05 s…300 h a 110…240 V, z 24 V, z 42…48 V

1 C/O contact 8 A RE7TM11BU

0 .05 s to 300 h z 24…240 V 1 C/O contact 8 A RE22R1MAMR

A, At, B, C, D, Di, H, Ht 0 .1 s…10 h c 24 V, a 24…240 V 1 C/O contact 8 A RE17RMEMU

A, B, C, Di 0 .02 s…300 h z 24…240 V 2 C/O contacts 5 A RE48AML12MW

A, C, D, Di, H, Qg, Qt, W 0 .05 s…300 h a 110…240 V, z 24 V, z 42…48 V

2 C/O contacts 8 A RE7MY13BU

0 .05 s…300 h z 24…240 V 2 C/O contacts 8 A RE7MY13MW

A, At, Aw, C, Ct, D, Dt, Dw, Di, Dit, Diw, H, Ht, Hw, Qg, Qgt, Qt, Qtt, Qtw, W, Wt

0 .05 s…300 h z 24…240 V 2 C/O contacts 8 A RE22R2MYMR

A, At, Aw, C, Ct, D, Dt, Dw, Di, Dit, Diw, H, Ht, Hw, W, Wt, Ac, Act

0 .05 s…300 h z 24…240 V 1 C/O contact 8 A RE22R1MYMR

Zelio Timer Relays

Page 8: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

7

Selection (continued)

Selection table (continued)Functions Timing

rangeSupply voltage

Type of output

Rated current

Relay

A, C, D, Di, H, W 0 .05 s…300 h a 110…240 V, z 24 V, z 42…48 V

1 C/O contact 8 A RE7ML11BU

A, D, Di, H 0 .1 s…10 s and 3 s…300 s

z 24…240 Va 24…240 V

1 solid state output 0 .7 A RE9MS21MW

A1, A2, H1, H2 0 .02 s…300 h z 24…240 V 2 C/O contacts 5 A RE48AMH13MW

Ac 0 .05 s…300 h a 110…240 V, z 24 V, z 42…48 V

1 C/O contact 8 A RE7MA11BU2 C/O contacts 8 A RE7MA13BU

0 .05 s…300 h z 24…240 V 2 C/O contacts 8 A RE22R2ACMRAc, Act 0 .05 s…300 h z 24…240 V 1 C/O contact 8 A RE22R1ACMRAd, Ah, N, O, P, Pt, Tl, Tt, W 0 .1 s…100 h c 24 V, a 24…240 V 1 C/O contact 8 A RE17RMXMU

0 .1 s…100 h c 24 V/a 24…240 V 2 C/O contacts 8 A RE22R2MXMUAk 0 .05 s…300 h a 110…240 V, z 24 V,

z 42…48 V1 C/O contact 8 A RE7MV11BU

Ak, Akt 0 .05 s to 300 h z 24…240 V 1 C/O contact 8 A RE22R1AKMR

B 0 .1 s…100 h c 24 V, a 24…240 V 1 C/O contact 8 A RE17RBMUC 0 .1 s…10 s z 24 V 1 C/O contact 8 A RE8RA11BTQ

0 .3 s…30 s 8 A RE8RA31BTQ3 s…300 s 8 A RE8RA21BTQ0 .1 s…100 h c 24 V, a 24…240 V 1 C/O contact 8 A RE17RCMU0 .1 s…10 s a 110…240 V 1 C/O contact 8 A RE8RA11FUTQ0 .3 s…30 s 8 A RE8RA31FUTQ3 s…300 s 8 A RE8RA21FUTQ20 s…30 min 8 A RE8RA41FUTQ0 .05 s…300 h z 24 V, a 110…240 V,

z 42…48 V1 C/O contact 8 A RE7RA11BU

8 A RE7RM11BU2 C/O contacts 8 A RE7RL13BU

0 .1 s…10 s a 24…240 V 1 solid state output 0 .7 A RE9RA11MW70 .3 s…30 s 0 .7 A RE9RA31MW73 s…300 s 0 .7 A RE9RA21MW740 s…60 min 0 .7 A RE9RA51MW70 .1 s…100 h 0 .7 A RE17LCBM

C, Ct 0 .05 s to 300 h z 24…240 V 1 C/O contact 2 C/O contacts

8 A 8 A

RE22R1CMRRE22R2CMR

D 0 .05 s…300 h z 24 V, a 110…240 V 1 C/O contact 8 A RE7CL11BU0 .1 s…10 s 8 A RE8CL11BUTQ0 .05 s…300 h z 24 V, a 110…240 V,

z 42…48 V2 C/O contacts 8 A RE7CP13BU

D, Dw 0 .05 s to 300 h z 24…240 V 1 C/O contact 2 C/O contacts

8 A 8 A

RE22R1DMRRE22R2DMR

H 0 .05 s…300 h z 24 V, a 110…240 V 1 C/O contact 8 A RE7PE11BU0 .1 s…10 s 8 A RE8PE11BUTQ0 .3 s…30 s 8 A RE8PE31BUTQ3 s…300 s 8 A RE8PE21BUTQ0 .05 s…300 h z 24 V, a 110…240 V,

z 42…48 V2 C/O contacts 8 A RE7PP13BU

0 .1 s…100 h a 24…240 V 1 solid state output 0 . 7 A RE17LHBMH, Hw 0 .05 s to 300 h z 24…240 V 1 C/O contact

2 C/O contacts8 A 8 A

RE22R1HMRRE22R2HMR

H, Ht 0 .1 s…100 h c 24 V, a 24…240 V 1 C/O contact 8 A RE17RHMUHe 0 .05 s…0 .5 s z 24 V, a 110…240 V 1 C/O contact 8 A RE8PT01BUTQK 0 .05 s…10 min z 24…240 V 1 C/O contact 5 A RE7RB11MW

0 .05 s…0 .5 s z 24 V, a 110…240 V 1 C/O contact 8 A RE8RB51BUTQ0 .1 s…10 s 8 A RE8RB11BUTQ0 .3 s…30 s 8 A RE8RB31BUTQ0 .05 s…10 min z 24…240 V 2 C/O contacts 5 A RE7RB13MW0 .05 s…10 min z 24…240 V 1 C/O contact

2 C/O contacts5 A 5 A

RE22R1KMR RE22R2KMR

K, He 0 .05 s to 300 h z 24…240 V 1 C/O contact 5 A RE22R1MKMR

Zelio Timer Relays

Page 9: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

8

Selection table (continued)Functions Timing

rangeSupply voltage

Type of output

Rated current

Relay

L, Li 0 .1 s…100 h c 24 V, a 24…240 V 1 C/O contact 8 A RE17RLMU0 .1 s…100 h a 24…240 V 1 solid state output 0 .7 A RE17LLBM0 .1 s…100 h z 12 V 1 C/O contact 8 A RE17RLJU0 .02 s…300 h z 24…240 V 2 timed C/O contacts 5 A RE48ACV12MW

L, Li, Lt 0 .05 s…300 h a 110…240 V, z 24 V, z 42…48 V

1 C/O contact 8 A RE7CV11BU

L, Lt, Li, Lit 0 .05 s…300 h z 24…240 V 1 C/O contact 8 A RE22R1MLMR

Q 0 .1 s…100 h c 24 V, a 24…240 Va 230…240 V, a 380 …440 V

1 C/O contact 1 C/O contact

8 A 8 A

RE22R1QMU RE22R1QMQ

Qc 0 .1 s…10 s z 24 V, a 110…240 V 1 C/O contact 8 A RE8YG11BUTQ0 .3 s…30 s 8 A RE8YG31BUTQ3 s…300 s 8 A RE8YG21BUTQ0 .05 s…300 h z 24 V, a 24…240 V 1 C/O contact 8 A RE22R1QCMU

Qe 0 .3 s…30 s z 24 V 1 N/O + 1 N/C 8 A RE8YA32BTQ0 .3 s…30 s a 110…240 V 1 N/O + 1 N/C 8 A RE8YA32FUTQ0 .3 s…30 s a 380…415 V 1 N/O + 1 N/C 8 A RE8YA32QTQ0 .3 s…30 s a 380…415 V 2 C/O contacts 8 A RE22R2QEMT0 .3 s…30 s z 24…240 V 2 C/O contacts 8 A RE22R2QEMR

Qg 0 .05 s…300 h z 24 V, a 110…240 V, z 42…48 V

1 N/O + 1 N/C 8 A RE7YR12BU

0 .05 s to 300 h z 24…240 V 2 C/O contacts 8 A RE22R2QGMR

Qt 0 .05 s…300 h z 24 V, a 110…240 V, z 42…48 V

2 C/O contacts 8 A RE7YA12BU

0 .05 s to 300 h z 24…240 V 2 C/O contacts 8 A RE22R2QTMR

W 0 .1 s…10 s z 24 V 1 C/O contact 8 A RE8PD11BTQ0 .3 s…30 s 8 A RE8PD31BTQ3 s…300 s 8 A RE8PD21BTQ0 .1 s…10 s a 110…240 V 1 C/O contact 8 A RE8PD11FUTQ0 .3 s…30 s 8 A RE8PD31FUTQ3 s…300 s 8 A RE8PD21FUTQ0 .05 s…300 h z 24 V, a 110…240 V,

z 42…48 V2 C/O contacts 8 A RE7PD13BU

W, Ht 0 .05 s…300 h z 24 V, a 110…240 V, z 42…48 V

1 C/O contact 8 A RE7PM11BU

W, Wt 0 .05 s…300 h z 24…240 V 2 C/O contacts 8 A RE22R2MWMR

Selection (continued) Zelio Timer Relays

Page 10: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

9

Functions

FunctionsU: SupplyR: Relay or solid state outputR1/R2: 2 timed outputsR2 inst .: Second output is instantaneous if the correct position is selectedT: Timing period

X1/X2/Y1: Control contacts Function diagram :Relay de-energizedTa: Adjustable on-delay

Tr: Adjustable off-delay Relay energizedOutput openOutput closed

Function A: Power on-delay relay1 output 2 outputs

The timing period T begins on energization .After timing, the output(s) R close(s) .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function Ac: On-delay and off-delay with control signal1 output 2 outputs

After power-up, and energization of Y1 the timing period T starts . At the end of this timing period, the output(s) R close(s) .With de-energization of Y1, the timing period T starts .At the end of this timing period T, the output (s) R revert(s) to its/their initial position .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .2 timed outputs (R1/R2) or 1 timed output (R1)

and 1 instantaneous output (R2 inst.).

Function Act: On-delay and off-delay with control signal and pause/summation control1 output 2 outputs

After power-up and energization of Y1 the timing period T starts and the timing can be interrupted/paused each time X1 energizes . When the cumulative total of time period elapsed reaches the pre-set value T, the output(s) R close(s) .With de-energization of Y1, the timing T starts and it can be interrupted/paused each time X1 energizes . When the cumulative total of time period elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial position .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

T = t1 + t2 + … T = t’1 + t’2 + …

Function Ad: Pulse delayed relay with control signal1 output 2 outputs

After power-up, pulsing or maintaining of energization of Y1 starts the timing T .At the end of this timing period T, the output (s) R close(s) . The output(s) R will revert to its initial position the next time Y1 is pulsed or maintained .

Zelio Timer Relays

R1

U

TR1

U

R2

R2 inst.T

R1

U

Y1

R2

R2 inst.T T

Y1

R1

X1

U

t1

t2

t'1

t'2

Y1

R1

R2

R2 inst.

X1

U

t1

t2

t'1

t'2

T

U

Y1

R1T

R1

Y1

U

R2

R2 inst.T T

R1

Y1

U

T T

T = t1 + t2 + … T = t’1 + t’2 + …

Page 11: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

10

Functions (continued)

Functions (continued)Function Ah: Pulse delayed relay (single cycle) with control signal1 output 2 outputs

After power-up, pulsing or maintaining control contact Y1 starts the timing T .A single cycle then starts with 2 timing period T of equal duration (start with output in rest position) .Output R changes state at the end of the first timing period T and reverts to its initial position at the end of the second timing period T .Control contact Y1 must be reset in order to re-start the single flashing cycle.

Function Ak: Asymmetrical on-delay and off-delay with external control1 output

After power-up and energization of the control contact Y1, timing starts for a period Ta .At the end of this timing period Ta, the output(s) R close(s) .De-energization of control contact Y1 causes a second timing period Tr to start .At the end of this timing period Tr, the output(s) R reverts to its initial state .

Function Akt: Asymmetrical on-delay and off-delay with control signal and with pause/summation control1 output

After power-up and energization of Y1, timing starts for a period Ta and timing can be interrupted/paused each time X1 energizes . When the cumulative total of time period elapsed reaches the pre-set value Ta, the output(s) R close(s) .De-energization of Y1 causes a second timing period Tr to start and can be interrupted/paused each time X1 energizes . When the cumulative total of time periods elapsed reaches the pre-set value Tr, the output(s) R reverts to its initial state .

Ta = t1 + t2 + …Tr = t’1 + t’2 + …

Function At: Power on-delay relay with pause/summation control1 output 2 outputs

After power-up, the timing period T starts . Timing can be interrupted /paused each time X1 energizes . Note: Except for RE17p, RE22R2AMU, RE22R2MMW, RE22R2MMU, RE22R2MJU, timing can be interrupted/paused each time Y1 energizes . When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R close(s) .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

T = t1 + t2 + …

T = t1 + t2 + …

Zelio Timer Relays

U

Y1

R1T T T T

R1

Y1

U

R2

R2 inst.T T T T

R1

U

Y1

Ta Tr

Y1

R1

X1

U

t'1

t2 t'2

t1

R1

X1

U

t1 t2R1

X1

U

R2

R2 inst.t1 t2

R1

Y1

U

t1 t2R1

Y1

U

R2

R2 inst.T T

T = t1 + t2 + …

T = t1 + t2 + …

Page 12: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

11

Functions (continued) Zelio Timer Relays

Functions (continued)Function Aw: Power on-delay with retrigger/restart control1 output 2 outputs

The timing period T starts on energization . At the end of the timing period T, the output(s) R closes .Closing of the control contact Y1 makes the output R open . Opening of control contact Y1 restarts timing period T . At the end of the timing period T, the output(s) R close(s) .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Function B: Interval relay with control signal1 output 2 outputs

After power-up, pulsing or maintaining control contact Y1 starts the timing T .The output R closes for the duration of the timing period T then reverts to its initial state . The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Function Bw: Double interval relay with control signal1 output 2 outputs

After power-up, transition of Y1 (either from energization to de-energization or vice-versa) will cause the output(s) R to close(s) for the duration of the timing period T and then revert(s) to its/their initial state .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Function C: Off-delay relay with control signal1 output 2 outputs After power-up and closing of the control

contact Y1, the output R closes .When control contact Y1 re-opens, timing T starts .At the end of the timing period, output(s) R revert(s) to its/their initial state .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function Ct : Off-delay relay with control signal and with pause/summation control

After power-up and energization of Y1 the output(s) R close(s) .When Y1 de-energizes, timing starts and can be interrupted/paused each time X1 energizes . When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

R1

Y1

U

T T

U

Y1

R1T T

R1

Y1

U

R2

R2 inst.T T

U

Y1

R1T T

R1

Y1

U

R2

R2 inst.T T

R1

Y1

U

T

R1

Y1

U

R2

R2 inst.

T

Y1

R1

X1

U

t1 t2R1

Y1

X1

U

R2

R2 inst.t1 t2

T = t1 + t2 + …

R1

Y1

U

R2

R2 inst.TT

T = t1 + t2 + …

Page 13: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

12

Functions (continued)Function D: Symmetrical flasher relay (starting pulse-off)1 output 2 outputs

Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Note: Function D with Y1 is only for RE17 reference range and RE22R2MJU, RE22R2MMU, RE22R2MMW references .

Function Di: Symmetrical flasher relay (starting pulse-on)1 output 2 outputs

Repetitive cycle with two timing periods Tof equal duration, with output(s) Rchanging state at the end of each timingperiod T .The second output (R2) can be eithertimed (when set to “TIMED”) orinstantaneous (when set to “INST”) .

timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function Dt : Symmetrical flashing relay (starting pulse-off) and with pause/summation control1 output 2 outputs

On power-up, output(s) R starts at its/their initial state for timing duration T and the timing can be interrupted/paused each time X1 energizes . When the cumulative total of time period elapsed reaches the pre-set value T, then the output(s) R close(s) .The output(s) R close state will remain for the same timing duration T and the timing can be interrupted/paused each time X1 energizes . When the cumulative total of time period elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state .This cycle is repeated indefinitely until power supply is removed .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Zelio Timer RelaysFunctions (continued)

R1

U

T T T T T TR1

U

R2

R2 inst.

T T T

R1

Y1

U

T T T T T TR1

Y1

U

R2

R2 inst.T T T

R1

U

T T T T T TR1

U

R2

R2 inst.T T T

R1

X1

U

T t2

t'1t1

t'2R1

X1

U

R2

R2 inst.T t2

t'1t1

t'2T = t1 + t2 + …T = t’1 + t’2 + …

T = t1 + t2 + …T = t’1 + t’2 + …

Page 14: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

13

Zelio Timer RelaysFunctions (continued)

Functions (continued)Function Dit : Symmetrical flashing relay (starting pulse-on) and with pause/summation control1 output 2 outputs

T= t1 + t2 + … T = t’1 + t’2 +…

On power-up, output(s) R starts when output(s) R close(s) for time duration T and the time can be interrupted/paused each time X1 energizes . When the cumulative total of time periods elapsed reaches the pre-set value T, then revert(s) to its/their initial state .The output(s) R at initial state will remain for the same time duration T and the time can be interrupted/paused each time X1 energizes . When the cumulative total of time period elapsed reaches the pre-set value T, the output(s) R change(s) to close state . This cycle is repeated indefinitely until power supply is removed.The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Function Dw: Symmetrical flashing relay (starting pulse-off) and with retrigger/restart control1 output 2 outputs

On power-up, output(s) R starts at its/their initial state for timing duration T then changes to output(s) R close(s) for the same timing duration T . This cycle is repeated indefinitely until power supply removal .At any state of the output(s) R when Y1 energizes, the output(s) R will revert to its/their initial state and followed by Y1 de-energizes then same operation as described at the beginning resumes .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Function Diw: Symmetrical flashing relay (starting pulse-on) and with retrigger/restart control1 output 2 outputs

On power-up, output(s) R starts when output(s) R close(s) for timing duration T and revert(s) to its/their initial state for the same timing duration T . This cycle is repeated indefinitely until power supply is removed . At any state of the output(s) R when Y1 energizes, the output(s) R will revert to its/their initial state and followed by Y1 de-energizes then restarts the same operation as described at the beginning .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Function H: Interval relay1 output 2 outputs

On energization of the relay, timing period T starts and the output(s) R close(s) .At the end of the timing period T, output(s) R revert(s) to its/their initial state .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

R1

X1

U

T t2 t'1

t1 t'2

R1

X1

U

R2

R2 inst.T t2 t'1

t1 t'2

R1

Y1

U

T T T TR1

Y1

U

R2

R2 inst.

T T T T

R1

Y1

U

T T T TR1

Y1

U

R2

R2 inst.

T T T T

R1

U

TR1

U

R2

R2 inst.T

T= t1 + t2 + … T = t’1 + t’2 +…

Page 15: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

14

Functions (continued)Function He: Pulse-on de-energization1 output

After energization of power supply > 80 ms followed by de-energization of power supply, the output(s) R close(s) for the duration of a timing period T then revert(s) to its/their initial state .After energization of power supply < 80 ms followed by de-energization of power supply, the output(s) R close(s) and will not be able to sustain for the duration of a timing period T before revert(s) to its/their initial state .

Function Ht: Interval relay (summation) with control signal 1 output 2 outputs

On power-up, output(s) R close(s) and timing period T starts, the timing can be interrupted/paused each time X1 energizes . When the cumulative total of time period elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state . The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .Note: For RE17p, RE22R2AMU, RE22R2MMW, RE22R2MMU, RE22R2MJU, timing can be interrupted/paused each time Y1 energizes .

Function Hw : Interval Relay and with retrigger/restart control1 output 2 outputs

On energization of power supply, output(s) R close(s) and timing period T starts . At the end of the timing period T, the output(s) R revert(s) to its/their initial state .At any state of the output(s) R when Y1 energizes and then de-energizes, the output(s) R close(s) and restarts the same operation as described at the beginning .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Function K: Delay on de-energization (without auxiliary supply)1 output 2 outputs

On energization, the output(s) R close(s) .On de-energization, timing period T starts and, at the end of this period, the output(s) R revert to its/their initial state .The energization of power supply > Tk is necessary to sustain the timing period T .There are 3 references with different Tk as follows:(a) RE22R1KMR --> Tk > 1 s(b) RE22R2KMR --> Tk > 1 s(c) RE22R1MKMR --> Tk > 80 ms

Zelio Timer RelaysFunctions (continued)

R1

U

>80ms <80ms

T <T

R1

U

X1/Y1

t1 t2

R1

Y1

U

T T

R1

Y1

U

R2

R2 inst.T T

> Tk

R1

U

T

R1

U

R2

T

> Tk

R1

X1/Y1

U

R2

R2 inst.

t1 t2

T = t1 + t2 + …

T = t1 + t2 + …

Page 16: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

15

Zelio Timer RelaysFunctions (continued)

Functions (continued)Function L: Asymmetrical flasher relay (starting pulse-off)1 output 1 output

Repetitive cycle consisting of two, independently adjustable timing periods Ta and Tr . Each timing period corresponds to a different state of the output R .

Function Li: Asymmetrical flasher relay (starting pulse-on)1 output 1 output

Repetitive cycle consisting of two, independently adjustable timing periods Ta and Tr . Each timing period corresponds to a different state of the output R .

Function Lt: Asymmetrical flashing with partial stop of timing1 output

Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr . Each timing period corresponds to a different state of the output R .Control contact X1 can be operated to partially stop timing periods Ta and Tr .

Tr = t1 + t2 + … Ta = t’1 + t’2 + …

Function Lit: Asymmetrical flashing relay (starting pulse-on) and with pause/summation control1 output

On energization of power supply, output(s) R close(s) for timing duration Ta and the timing can be interrupted/paused each time X1 energizes . When the cumulative total of time periods elapsed reaches the pre-set value Ta, the output(s) R revert(s) to its/their initial state .The output(s) R at intial state will remain for timing duration Tr, the timing can be interrupted/paused each time X1 energizes . When the cumulative total of time periods elapsed reaches the pre-set value Tr, then changes to output(s) R close(s) .This cycle is repeated indefinitely until power supply is removed .

Function N: Safe guard relay1 output 2 outputs

After power-up and an initial control pulse Y1, the output R closes .If the interval between two control pulses Y1 is greater than the set timing period T, timing elapses normally and the output R opens at the end of the timing period . If the interval is not greater than the set timing period, the output R remains closed until this condition is met .

R1

U

Tr Ta TaTrR1

Y1

U

Tr Ta TaTr

R1

X2

U

Ta Tr TrTa

R1

U

Ta Tr TrTa

R1

X1

U

t1 t2 t'1 t'2

X2

R1

X1

U

t2 t'1 t'2t1

U

Y1

R1T

R1

Y1

U

R2

R2 inst.T

Ta = t1 + t2 + … Tr = t’1 + t’2 + …

Page 17: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

16

Functions (continued) Zelio Timer Relays

Functions (continued)Function O: Delayed safe-guard relay1 output 2 outputs

An initial timing period T begins on energization . At the end of this timing period, the output R closes . When there is a control pulse Y1, the output R reverts to its initial state and remains in that state until the interval between two control pulses is less than the value of the set timing period T . Otherwise, the output R closes at the end of the timing period T .

Function P: Pulse delayed relay with fixed pulse length1 output 2 outputs

The timing period T starts on energization .At the end of this period, the output R closes for a fixed time P and then revert(s) to its/their initial state . .

Function Pt: Pulse delayed relay (summation and fixed pulse length) with control signal off1 output 2 outputs

On energization, timing period T starts (it can be interrupted by operating control contact Y1) .When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R close(s) for a fixed time P then revert(s) to its/their initial state .

Function Q: Star-Delta Relay (2 N/O output with same common)2 outputs

On energization of power supply, the output R1 closes such that it energizes Star contactor + Main contactor and the timing T starts (Star connection time duration starts) .At the end of the timing period T, the output R1 reverts to its initial state such that de-energizes Star contactor and causes t transition time starts .At the end of the transition time, the output R2 closes such that energizes Delta contactor .

Function Qc: Star-delta timing (1 C/O output)1 output

On energization of power supply, the output R initializes at its initial state to energize Star contactor + Main contactor and the timing T starts (Star connection time duration starts) .At the end of the time period T, the output R closes such that it de-energizes Star contactor and the power supply to start t transition time .At the end of the transition time, the output R reverts to its initial state such that it energizes Delta contactor .

Function Qe: Star-delta timing (1 N/C + 1 N/O output with split common)2 outputs

On energization of power supply, the output R1 is at its intitial state such that energizes Star contactor + Main contactor and the timing T starts (Star connection time duration starts) .At the end of the timing period T, the output R1 opens such that de-energizes Star contactor and causes t transition time starts .At the end of the transition time, the output R2 closes such that energizes Delta contactor .

P = 500 ms

T = t1 + t2 + …P = 500 ms

t = 50 ms

U

Y1

R1T T t<T T

R1

Y1

U

R2

R2 inst. T T t<T T

U

R1T P

R2

R1

U

R2 inst.T P

U

Y1

R1t2 Pt1

U

R1T t

R1

U

R2T t

R1

U

R2T t

R1

Y1

U

R2

R2 inst.t2 Pt1

Page 18: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

17

Functions (continued) Zelio Timer Relays

Functions (continued)Function Qg: Star-delta timing (2 C/O output with same common)2 outputs

On energization of power supply, the output R1 closes such that it energizes Star contactor + Main contactor and the timing T starts (Star connection time duration starts) .At the end of the timing period T, the output R1 reverts to its initial state such that de-energizes Star contactor and causes t transition time starts .At the end of the transition time, the output R2 closes such that energizes Delta contactor .

Function Qt: Star-delta timing (2 C/O output with split common)2 outputs

On energization of power supply, the output R1 and R2 initializes at its initial state such that it energizes Star contactor + Main contactor and the timing T starts (Star connection time duration starts) .At the end of the timing period T, the output R1 closes such that it de-energizes Star contactor and causes t transition time to start .At the end of the transition time, the output R2 closes such that energizes Delta contactor .

Function Qgt : Star-delta relay (2 C/O with same common) with pause/summation control2 outputs

Insert new function hereHeading: Function Qgt : Star-Delta Relay (2 C/O with same common) with pause/summation controlOn energization of power supply, the output R1 closes such that it energizes Star contactor + Main contactor and the timing T starts (Star connection time duration starts) .During Star connection time, the timing can be interrupted/paused each time X1 energizes . When the cumulative total of time periods elapsed reaches the pre-set value T, R1 reverts to its initial state such that it de-energizes Star contactor and causes t transition time to start .At the end of the transition time, the output R2 closes such that it energizes Delta contactor .

Function Qtt : Star-delta relay (2 C/O output with split common) with pause/summation control2 outputs

On energization of power supply, the output R1 and R2 initializes at its initial state such that it energizes Star contactor + Main contactor and the timing T starts (Star connection time duration starts) .During Star connection time, the timing can be interrupted/paused each time X1 energizes . When the cumulative total of time period elapsed reaches the pre-set value T, the output R1 closes such that it de-energizes Star contactor andcauses t transition time to start .At the end of the transition time, the output R2 closes such that it energizes Delta contactor .

Function Tl: Bistable relay with control signal on1 output 2 outputs

After energization of power supply and Y1, the output(s) R close(s) . The subsequent energization of Y1 cause the output(s) R revert(s) to its/their initial state. This cycle is repeated indefinitely until power supply is removed .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

U

R1

R2T t

R1

U

X1

R2t2t1 t

R1

U

X1

R2t2t1 t

T = t1 + t2 + …

T = t1 + t2 + …

R1

Y1

U

R2

R2 inst.

∞ ∞∞

U

Y1

R1

∞ ∞∞

R1

U

R2T t

Page 19: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

18

Functions (continued)Function Tt: Retriggerable bistable relay with control signal on1 output 2 outputs

After energization of power supply and on energization of Y1, the output(s) Rclose(s) and starts the timing T .If the duration interval between 2 consecutive energization of Y1 is greater than the pre-set value T, the output(s) R will toggle from its/their present status at the end of the timing period .If the duration interval between 2 consecutive energization of Y1 is less than the pre-set value T, the output(s) R toggle from its/their present status as soon as Y1 energizes without completing T duration .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

Function W: Interval relay with control signal off1 output 2 outputs

After power-up and opening of the control contact Y1, the output(s) R close(s) for a timing period T .At the end of this timing period the output(s) revert to its/their initial state .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).

Function Wt: Interval relay with control signal off and with pause/summation control1 output 2 outputs

After power-up and opening of the control contact Y1, the output(s) R close(s) for a timing period T . Timing can be interrupted/paused each time X1 energizes .When the cumulative total of time period elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state .The second output (R2) can be either timed (when set to “TIMED”) or instantaneous (when set to “INST”) .

U

Y1

R1T Tt<T

R1

Y1

U

R2

R2 inst.T Tt<T

R1

Y1

U

T

R1

Y1

U

R2

R2 inst.

T

R1

Y1

X1

U

t1 t2R1

Y1

X1

U

R2

R2 inst.

t1 t2

Functions (continued) Zelio Timer Relays

T = t1 + t2 + …

Page 20: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

19

RE48ATM12MWFunction A: Delay on energization

RE48ACV12MWFunction L: Asymmetrical flashing, start with output in rest position

Function Li: Asymmetrical flashing, start with output in operating position

RE48AML12MWFunction A: Delay on energization Function B: Timing on impulse, one shot

Function C: Timing after opening of control contact Function Di: Symmetrical flashing, start with output in operating position

RE48AMH13MWFunctions A1, A2: Delay on energization Functions H1, H2: Pulse-on energization

Note: If A1 or H1 is selected, only R2 is timed, R1 is instantaneous

T T

Un

R

t3 ta tc

t2 tb

t1

Un

Gate

2 - 6Nor/Inv

ToffTon

Toff = t1+t2+t3 Ton = ta+tb+tc

R

Toff ToffTon

t3 ta

t2 tb

t1 t1

Un

Gate

2 - 6Nor/Inv

Ton

Ton = t1+t2+t3 Toff = ta+tb+tc

R

ToffTon

T Tt2

T = t1 + t2 + t3

t1 t3 T T T Tt

Un

Start

Gate

Reset

R

T T T t1 t3

t2

T = t1 + t2 + t3

T T T

Un

Start

Gate

Reset

R

T T t1 t3

t2T = t1 + t2 + t3

T T

Un

Start

Gate

Reset

Ouput

T T T T T Tt1t2

T = t1 + t2

t1 t2 T T T T T T T T TT T T TT

Un

Start

Gate

Reset

Output

T T

Un

R2

R1T T

Un

R2

R1

Functions (continued) Zelio Timer RelaysElectronic relays, relay output, 48 x 48

Page 21: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

20

Modular relays with solid state output 0.7 ASingle functionTiming ranges Functions Voltages Reference Weight

V kg/lb1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

A z 24…240 RE17LAMW 0 .060/0.132

H a 24…240 RE17LHBM 0 .060/0.132

C a 24…240 RE17LCBM 0 .060/0.132

Dual function1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

L, Li

a 24…240 RE17LLBM 0 .060/0.132

Multifunction1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

A, At, B, C, H, Ht, D, Di, Ac, Bw

a 24…240 RE17LMBM 0 .060/0.132

Modular relays with relay output, 1 C/O contactSingle functionTiming ranges Functions Voltages Reference Weight

V kg/lb1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

B c 24/a 24…240 RE17RBMU 0 .070/0.154

C c 24/a 24…240 RE17RCMU 0 .070/0.154

Dual function1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

A, At

c 24/a 24…240 RE17RAMU 0 .070/0.154

H, Ht

c 24/a 24…240 RE17RHMU 0 .070/0.154

L, Li

c 24/a 24…240 RE17RLMU 0 .070/0.154

z 12 RE17RLJU 0 .070/0.154

Multifunction1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

A, At, B, C, H, Ht, D, Di, Ac, Bw

z 12 RE17RMJU 0 .070/0.154

c 24/a 24…240 RE17RMMU 0 .070/0.154

z 12…240 RE17RMMW 0 .070/0.154

RE17RMMWS (1) 0 .070/0.154

Ad, Ah, N, O, P, Pt, Tl, Tt, W

c 24/a 24…240 RE17RMXMU 0 .070/0.154

1 s, 10 s, 1 min 10 min, 1 h, 10 h

A, At, B, C, H, Ht, D, Di

c 24/a 24…240 RE17RMEMU 0 .070/0.154

(1) Connection by spring terminals.

PF1

2110

0A

RE17LAMW

PF1

2110

3B

RE17LLBM

PF1

2111

3A

RE17RpMp

Zelio Timer RelaysModular relays with solid state or relay output, width 17 .5 mm/0.689 in.

References

Solid state outputv Multifunction, dual function or single functionv Multi-range (7 selectable ranges)v Multivoltagev Solid state output: 0.7 Av Screw terminals

Relay output, 1 C/O contactv Dual function or single functionv Multi-range (7 selectable ranges)v Multivoltagev 1 relay output: 8 Av Screw and Spring terminalsv State indication by 1 LEDv Option of supplying a load in parallelv 3-wire sensor control option

Page 22: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

21

ReferencesSingle functionTiming ranges

Functions No. of relay outputs

Voltages Reference Weight

V kg/lb10 time range selection 1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 30 min, 300 min, 30 h, 300 h

Ac 2 z 24…240 RE22R2ACMR 0 .105/ 0.231

Qg 2 z 24…240 RE22R2QGMR 0 .105/ 0.231

Qt 2 z 24…240 RE22R2QTMR 0 .105/ 0.231

7 time range selection1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 10 min

K 1 z 24…240 RE22R1KMR 0 .100/ 0.220

2 z 24…240 RE22R2KMR 0 .100/ 0.220

7 time range selection0.5 s, 1 s, 3 s, 10 s, 30 s, 100 s, 300 s

Qc 1 z 24/a 24…240 RE22R1QCMU 0 .080/ 0 .176

Single range selection30 s

Qe 2 z 24…240 RE22R2QEMR 0 .090/ 0.198

2 a 380…415 RE22R2QEMT 0 .090/ 0.198

Dual function10 time range selection1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 30 min, 300 min, 30 h, 300 h

A, Aw 1 z 24…240 RE22R1AMR 0 .100/ 0.220

2 z 24…240 RE22R2AMR 0 .105/ 0.231

C, Ct 1 z 24…240 RE22R1CMR 0 .100/ 0.220

2 z 24…240 RE22R2CMR 0 .105/ 0.231

Ac, Act 1 z 24…240 RE22R1ACMR 0 .100/ 0.220

Ak, Akt 1 z 24…240 RE22R1AKMR 0 .100/ 0.220

D, Dw 1 z 24…240 RE22R1DMR 0 .100/ 0.220

2 z 24…240 RE22R2DMR 0 .105/ 0.231

H, Hw 1 z 24…240 RE22R1HMR 0 .100/ 0.220

2 z 24…240 RE22R2HMR 0 .105/ 0.231

Wt, W 2 z24…240 RE22R2MWMR 0 .105/ 0.231

7 time range selection0.5 s, 1 s, 3 s, 10 s, 30 s, 100 s, 300 s

K, He 1 z24…240 RE22R1MKMR 0 .100/ 0.220

10 time range selection1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 30 min, 300 min, 30 h, 300 h

A, At, Aw 1 z 24…240 RE22R1MAMR 0 .100

A, At, Aw, Ac, Act, C, Ct, D, Dt, Dw, Di, Dit, Diw, H, Ht, Hw, W, Wt,

1 z 24…240 RE22R1MYMR 0 .100/ 0.220

A, At, Aw, C, Ct, D, Dt, Dw, Di, Dit, Diw, H, Ht, Hw, Qg, Qgt, Qt, Qtt, W, Wt

2 z 24…240 RE22R2MYMR 0 .105/0.231

L, Li, Lt, Lit 1 z 24…240 RE22R1MLMR 0 .100/ 0.220

(1) The diagnostic button is not available for the K function related references (RE22R1KMR, RE22R2KMR and RE22R1MKMR).

Zelio Timer RelaysModular single, dual or multifunction relays with diagnostic button and dial pointer, relay output, width 22 .5 mm/0.886 in.

References

Output 1 C/O and 2 C/O contactsv Multifunction, dual function, or single functionv Multiple timing ranges (up to 10 switchable ranges)v Multivoltagev 1 or 2 relay outputs: 8 A - 250 Vv Screw terminalsv State indication by LEDv Option of supplying a load in parallelv 3-wire sensor control optionv Diagnostic button (1) and dial pointer LED indicator

RE22R2QTMR

PF1

5011

6A

RE22R2QEMR

PF1

5011

8A

RE22R2HMR

PF1

5010

3A

RE22R1MYMR

PF1

5011

4A

RE22R2KMR

PF1

5012

2A

Page 23: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

22

ReferencesMulti functionTiming ranges

Functions No. of relay outputs

Voltages Reference Weight

V kg/lb

7 time range selection1 s,10 s, 1min,10 min, 1h,10 h, 100 h

Q 1 c 24/a 24…240 RE22R1QMU 0 .090/0.198

1 a 230/380 RE22R1QMQ 0 .090/0.198

Dual function7 time range selection1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

A, At 2 c 24/a 24…240 RE22R2AMU 0 .090/ 0.198

Multi function1 s,10 s,1 min,10 min,1 h,10 h,100 h

A, At, B, C, H, Ht, Di, D, Ac, Bw

2 c 24/a 24…240 RE22R2MMU(1)

0 .090/0.198

z 12 RE22R2MJU(1)

0 .090/0.198

z 12…240 RE22R2MMW(1)

0 .090/0.198

Ad, Ah, N, O, P, Pt, Tl, Tt, W

2 c 24/a 24…240 RE22R2MXMU(1)

0 .090/0.198

(1) Connection by screw terminals.

Zelio Timer RelaysModular single, dual or multifunction relays, relay output, width 22 .5 mm/0.886 in.

References

RE22R1QMU

PF1

3209

0

RE22R2AMU

PF1

3209

2

RE22R2MMU

PF1

3209

3

Output 1 C/O and 2 C/O contactsv Multifunction, dual function or single functionv Multiple timing ranges (7 switchable ranges)v Multivoltagev 1 or 2 relay outputs: 8 A - 250 Vv Screw or spring terminalsv State indication by LEDv Option of supplying a load in parallelv 3-wire sensor control option

Page 24: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

23

ReferencesTiming ranges

Functions No. of relay outputs

Voltages Reference Weight

V kg/lb0.05 s…300 h(10 ranges)

A, Aw, At

1 z 24, a 110…240,z 42…48

RE7TM11BU 0 .150/0.331

Ac 1 z 24, a 110…240,z 42…48

RE7MA11BU 0 .150/0.331

2 z 24, a 110…240,z 42…48

RE7MA13BU(symmetrical)

0 .150/0.331

Ak 1 z 24, a 110…240,z 42…48

RE7MV11BU 0 .150/0.331

C 1 z 24, a 110…240,z 42…48

RE7RA11BU 0 .150/0.331

1 z 24, a 110…240,z 42…48

RE7RM11BU(low level contact)

0 .150/0.331

2 z 24, a 110…240,z 42…48

RE7RL13BU(low level contact)

0 .150/0.331

Ht, W

1 z 24, a 110…240,z 42…48

RE7PM11BU 0 .150/0.331

L, Li, Lt

1 z 24, a 110…240,z 42…48

RE7CV11BU 0 .150/0.331

A, C, H, W, D, Di

1 z 24, a 110…240,z 42…48

RE7ML11BU 0 .150/0.331

PF1

0344

4SE

RE7TM11BU

PF1

0586

3SE

RE7MA11BU

PF5

1622

1

RE7CV11BU

Zelio Timer RelaysIndustrial single, dual or multifunction relays, relay output, width 22 .5 mm/0.886 in.

References

Output 1 C/O and 2 C/O contactsv Multifunction, dual function, or single functionv Multiple timing rangesv Multivoltagev Transparent, hinged, and sealable flap on front panel

Page 25: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

24

References (continued)Timing ranges

Functions No. of relay outputs

Voltages Reference Weight

V kg/lb0.05 s…300 h(10 ranges)

A 1 z 24,a 110…240

RE7TL11BU 0 .150/0.331

2 z 24, a 110…240,z 42…48

RE7TP13BU 0 .150/0.331

H 1 z 24,a 110…240

RE7PE11BU 0 .150/0.331

2 z 24, a 110…240,z 42…48

RE7PP13BU 0 .150/0.331

D 1 z 24,a 110…240

RE7CL11BU 0 .150/0.331

2 z 24, a 110…240,z 42…48

RE7CP13BU 0 .150/0.331

W 2 z 24, a 110…240,z 42…48

RE7PD13BU 0 .150/0.331

Qt 2 z 24, a 110…240,z 42…48

RE7YA12BU 0 .150/0.331

Qg 2 z 24, a 110…240,z 42…48

RE7YR12BU 0 .150/0.331

A, C, H, W, D, Di, Qg, Qt

2 z 24, a 110…240,z 42…48

RE7MY13BU 0 .150/0.331

2 z 24…240 RE7MY13MW 0 .150/0.331

0.05 s…10 min(7 ranges)

K 1 z 24…240 RE7RB11MW 0 .150/0.331

2 z 24…240 RE7RB13MW 0 .150/0.331

Output 1 C/O and 2 C/O contactsv Multifunction, dual function, or single functionv Multiple timing rangesv Multivoltagev Transparent, hinged, and sealable flap on front panel

Zelio Timer RelaysIndustrial single, dual or multifunction relays, relay output, width 22 .5 mm/0.886 in.

References (continued)

RE7TL11BU

PF1

0344

4SE

Page 26: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

25

ReferencesTiming ranges

Functions Voltages Unit reference (1)

Weight

V kg/lb0.05 s…0.5 s K z 24,

a 110…240RE8RB51BUTQ 0 .110/

0.243He z 24,

a 110…240RE8PT01BUTQ 0 .110/

0.2430.1 s…3 s A z 24,

a 110…240RE8TA61BUTQ 0 .110/

0.2430.1 s…10 s A z 24,

a 110…240RE8TA11BUTQ 0 .110/

0.243C z 24 RE8RA11BTQ 0 .110/

0.243a 110…240 RE8RA11FUTQ 0 .110/

0.243D z 24,

a 110…240RE8CL11BUTQ 0 .110/

0.243K z 24,

a 110…240RE8RB11BUTQ 0 .110/

0.243H z 24,

a 110…240RE8PE11BUTQ 0 .110/

0.243Qc z 24,

a 110…240RE8YG11BUTQ 0 .110/

0.243W z 24 RE8PD11BTQ 0 .110/

0.243a 110…240 RE8PD11FUTQ 0 .110/

0.2430.3 s…30 s A z 24,

a 110…240RE8TA31BUTQ 0 .110/

0.243C z 24 RE8RA31BTQ 0 .110/

0.243a 110…240 RE8RA31FUTQ 0 .110/

0.243H z 24,

a 110…240RE8PE31BUTQ 0 .110/

0.243K z 24,

a 110…240RE8RB31BUTQ 0 .110/

0.243Qc z 24,

a 110…240RE8YG31BUTQ 0 .110/

0.243Qe z 24 RE8YA32BTQ 0 .110/

0.243a 110…240 RE8YA32FUTQ 0 .110/

0.243a 380…415 RE8YA32QTQ 0 .110/

0.243W z 24 RE8PD31BTQ 0 .110/

0.243a 110…240 RE8PD31FUTQ 0 .110/

0.2433 s…300 s A z 24,

a 110…240RE8TA21BUTQ 0 .110/

0.243C z 24 RE8RA21BTQ 0 .110/

0.243a 110…240 RE8RA21FUTQ 0 .110/

0.243H z 24,

a 110…240RE8PE21BUTQ 0 .110/

0.243Qc z 24,

a 110…240RE8YG21BUTQ 0 .110/

0.243W z 24 RE8PD21BTQ 0 .110/

0.243a 110…240 RE8PD21FUTQ 0 .110/

0.24320 s…30 min A z 24,

a 110…240RE8TA41BUTQ 0 .110/

0.243C a 110…240 RE8RA41FUTQ 0 .110/

0.243(1) These products are sold in packs of 10.

Zelio Timer RelaysIndustrial single function relays, optimum, relay output, width 22 .5 mm/0.886 in.

References

v Single functionv Single timing rangev Output 1 C/O contactv Transparent, hinged, and sealable flap on front panel

PF1

0586

7SE

RE8TApppppp

Page 27: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

26

ReferencesSingle functionTiming ranges

Functions Voltages Reference Weight

V kg/lb0.1 s…10 s A z 24… 240 RE9TA11MW 0 .110/

0.243

C z 24… 240 RE9RA11MW7 0 .110/0.243

0.3 s…30 s A z 24… 240 RE9TA31MW 0 .110/0.243

C z 24… 240 RE9RA31MW7 0 .110/0.243

3 s…300 s A z 24… 240 RE9TA21MW 0 .110/0.243

C z 24… 240 RE9RA21MW7 0 .110/0.243

40 s…60 min A z 24… 240 RE9TA51MW 0 .110/0.243

C z 24… 240 RE9RA51MW7 0 .110/0.243

Multifunction0.1 s…10 s,0.3 s…30 s

A z 24… 240 RE9MS21MW 0 .110/0.243

H, D, Di

a 24…240

Zelio Timer RelaysIndustrial single or multifunction relays, solid state output, width 22 .5 mm/0.886 in.

References

RE9pAp1MW

PF1

2110

0A

RE9MS21MW

Solid state outputv Multifunction or single functionv Multivoltagev Screw terminalsv Transparent, hinged, and sealable flap on front panel

PF1

0586

9

Page 28: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

27

ReferencesSingle functionTiming ranges

Functions No. of relay outputs

Voltages Reference Weight

V kg/lb0.1 s…1 s, 1 s…10 s, 0.1 min…1 min, 1 min…10 min, 0.1 h…1 h, 1 h…10 h, 10 h…100 h(7 switchable ranges)

A 2 c 12 REXL2TMJD 0 .050/0.110

c 24 REXL2TMBD 0 .050/0.110

a 24 (50/60 Hz) REXL2TMB7 0 .050/0.110

a 120 (50/60 Hz) REXL2TMF7 0 .050/0.110

a 230 (50/60 Hz) REXL2TMP7 0 .050/0.110

4 c 12 REXL4TMJD 0 .050/0.110

c 24 (1)

REXL4TMBD 0 .050/0.110

a 24 (50/60 Hz)(1)

REXL4TMB7 0 .050/0.110

a 120 (50/60 Hz) REXL4TMF7 0 .050/0.110

a 230 (50/60 Hz)

REXL4TMP7 0 .050/0.110

Sockets for relaysContact terminal arrangement

For use with relays Connection Unit reference(2)

Weight kg/lb

Mixed (3) REXL2TMpp, REXL4TMpp

Screw clamp RXZE2M114(5)

0 .048/0.106

REXL2TMpp, REXL4TMpp

Connector RXZE2M114M(6)

0 .056/0.123

Separate (4) REXL2TMpp Connector RXZE2S108M 0 .070/0.154

REXL4TMpp Connector RXZE2S114M 0 .058/0.128

REXL2TMppREXL4TMpp

Spring clamp RXZE2S114S 0.070/ 0.154

(1) For c 48 V supply, additional resistor 560 W 2 W/c 24 V. For a 48 V, additional resistor 390 W 4 W/a 24 V.

(2) These products are sold in lots of 10.(3) The inputs are mixed with the relay's supply, with the outputs being located on the opposite side

of the socket.(4) The inputs and outputs are separated from the relay supply.(5) Thermal current Ith: 10 A.(6) Thermal current Ith: 12 A.

Zelio Timer RelaysMiniature plug-in relays, relay output

References

Output, 2 C/O and 4 C/O contactsv Miniature and plug-in (21 x 27 mm/0.827 x 1.062 in.)v Single function: function A = delay on energizationv Rated current a 5 Av 7 timing ranges (0.1 s to 100 h)v Multivoltagev Excellent immunity to interferencev Power on and relay energized indication by 2 LEDs

RXZE2M114

PF1

0601

4

REXL4TMpp

PF5

1621

9

REXL2TMpp

PF5

1621

8

Page 29: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

28

References8-pin relayTiming ranges Function No. of relay

outputsVoltages Reference Weight

V kg/lb1.2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 h

A

1 z 24…240 RE48ATM12MW 0 .140/0.309

A1, A2, H1, H2

2 of which 1 instantaneous

z 24…240 RE48AMH13MW 0 .140/0.309

11-pin relay1.2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 h

L, Li

2 z 24…240 RE48ACV12MW 0 .140/0.309

A, B, C, Di

2 z 24…240 RE48AML12MW 0 .140/0.309

SocketsDescription Number

of pinsFor use with relays

Sold in lots of

Unit reference

Weight kg/lb

IP 20 sockets with connection by connector and mixed contact terminals (1)

8 RE48ATM12MW, RE48AMH13MW

10 RUZC2M 0 .054/0.119

11 RE48ACV12MW, RE48AML12MW

10 RUZC3M 0 .054/0.119

IP 20 socket with screw terminal connections on rear face

11 RE48ACV12MW, RE48AML12MW

1 RE48ASOC11AR –

Connectors and protective coverIP 20 solder connectors 8 RE48ATM12MW,

RE48AMH13MW1 RE48ASOC8SOLD –

11 RE48ACV12MW, RE48AML12MW

1 RE48ASOC11SOLD –

Setting protection cover

– RE48ATM12MW, RE48ACV12MW, RE48AML12MW, RE48AMH13MW

1 RE48ASETCOV –

Protective coverIP 64

– RE48ATM12MW, RE48ACV12MW, RE48AML12MW, RE48AMH13MW

1 RE48AIPCOV –

(1) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the opposite side of the socket.

References Zelio Timer RelaysAnalog, electronic relays, relay output, 48 x 48

Output 2 C/O contactsv Time unit selector knobv Multifunction, single function, or dual functionv Multirangev Multivoltage v 2 relay outputs, 5 Av Panel-mounted or plug-inv LED indication

RE48ATM12MW

PF1

1045

2

RE48AMH13MW

PF1

1045

1

RUZC3M

DF5

2339

8

RE48ASOC11AR

1098

04

RE48ASOC8SOLD RE48ASOC11SOLD

1098

03

1098

05

RE48ASETCOV RE48AIPCOV

1098

06

1098

07

Page 30: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

29

RE88867305

RE88867415

ReferencesSingle functionTiming ranges

Functions No. of relay outputs

Voltages Reference Weight

V kg/lb1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

C 2 z 24…240 RE88867435 0 .080/0.176

Dual function1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

A, At

2 z 24…240 RE88867415 0 .080/0.176

Li, L

2 z 24…240 RE88867455 0 .080/0.176

Multifunction1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

A, At, B, C, H, Ht, Di, D, Ac, Bw

2 of which 1 instantaneous

z 24…240 RE88867305 0 .080/0.176

z 12 RE88867300 0 .080/0.176

z 12…240 RE88867303 0 .080/0.176

Sockets for 11-pin relaysContact terminal arrangement

For use with relays Connection Unit reference(1)

Weight

kg/lbMixed (2) RE88867ppp Connector RUZC3M 0 .054/

0.119

(1) These products are sold in packs of 10.(2) The inputs are mixed with the relay's supply, with the outputs being located on the opposite side

of the socket.

Zelio Timer RelaysUniversal plug-in relays, 11-pin,relay output, width 35 mm/1.377 in.

References

Output 2 C/O contactsv Multifunction, dual function or single functionv Multiple timing ranges (7 switchable ranges)v Multivoltagev 2 relay output: 8 A - 250 V (10 A UL)v Plug-inv State indication by 1 LEDv Option of supplying a load in parallelv 3-wire sensor control option

DF5

2339

8

RUZC3M

RE88867300

PF5

1621

4P

F516

213

PF5

1621

2

Page 31: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

30

ReferencesSingle functionTiming ranges

Functions No. of relay outputs

Voltages Reference Weight

V kg/lb1 s, 10 s , 1 min, 10 min, 1 h, 10 h, 100 h

A

2 z 24…240 RE88867215 0 .080/0.176

C 1 z 24…240 RE88867135 0 .080/0.176

Dual function1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

Li, L

1 z 24…240 RE88867155 0 .080/0.176

Multifunction1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

A, At, B, C, H, Ht, Di, D, Ac, Bw

1 z 24…240 RE88867105 0 .080/0.176

z 12 RE88867100 0 .080/0.176

z 12…240 RE88867103 0 .080/0.176

Sockets for 8-pin relaysContact terminal arrangement

For use with relays Unit reference(1)

Weight kg/lb

Mixed (2) RE888671pp,RE888672pp

RUZC2M 0 .054/0.119

(1) These products are sold in packs of 10.(2) The inputs are mixed with the relay's supply, with the outputs being located on the opposite

side of the socket.

PF5

1621

6

RE88867155

PF5

1621

7

RE88867105

Zelio Timer RelaysUniversal plug-in relays, 8-pin, relay output, width 35 mm/1.377 in.

References

Output 1 C/O or 2 C/O contactsv Multifunction, dual function or single functionv Multiple timing ranges (7 switchable ranges)v Multivoltagev 1 or 2 relay outputs: 8 A - 250 V (10 A UL) v Plug-inv State indication by 1 LEDv Option of supplying a load in parallelv 3-wire sensor control option

RE88867215

PF5

1621

5P

F106

031

RUZC2M

Page 32: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

31

Zelio Timer RelaysPanel-mounted universal, plug-in relays, relay output

References

Output 1 C/O or 2 C/O contactsv LCD displayv Multifunction or single functionv Multirangev Multivoltage v One 8 A relay outputv Reset function on front panelv Memory in the event of mains power interruptionv Locking of access to programming (RE8885710p and RE8885700p)v Upcount or downcount modev Internal supply by lithium battery (10 years at 20 °C)

RE8885740p

RE8885760p

PF1

1215

0SE

PF5

1622

0

References8-pin relayTimingranges

Functions No. of relay outputs

Voltages Reference Weight

V kg/lb99.99 s, 999.9 s, 9999 s,99 min 59 s, 99.99 min,999.9 min,9999 min, 99 h 59 min,99.99 h, 999.9 h, 9999 h

A,B,C,D,Di,H

1 c 12 and z 24…48

RE88857003 0 .100/ 0.220

z 24 anda 110…240

RE88857005 0 .100/ 0.220

z 24 and z 48

RE88857604 0 .100/ 0.220

z 24 and a 110, (50/60 Hz)

RE88857607 0 .100/ 0.220

z 24 and a 24…240, (50/60 Hz)

RE88857601 0 .100/ 0.220

11-pin relay99.99 s, 999.9 s, 9999 s,99 min 59 s, 99.99 min,999.9 min,9999 min, 99 h 59 min,99.99 h, 999.9 h, 9999 h

A,B,C, D,Di,H

1 c 12 and z 24…48

RE88857103 0 .100/ 0.220

z 24 anda 110…240

RE88857105 0 .100/ 0.220

z 24 and z 48

RE88857704 0 .100/ 0.220

z 24 and a 110 (50/60 Hz)

RE88857707 0 .100/ 0.220

z 24 and a 24…240 (50/60 Hz)

RE88857701 0 .100/ 0.220

Sockets for relaysNumberof pins

For use with relays Unitreference (1)

Weight kg/lb

8-pin connector RE8885740p, RE8885700p, RE8885760p RUZC2M 0 .054/0.119

11-pin RE8885710p, RE8885730p, RE8885770p RUZC3M 0 .054/0.119

(1) These products are sold in packs of 10..

DF5

2339

8

RUZC3M

Page 33: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

32

Index Product reference index

R

RE7CL11BU 24

RE7CP13BU 24

RE7CV11BU 23

RE7MA11BU 23

RE7MA13BU 23

RE7ML11BU 23

RE7MV11BU 23

RE7MY13BU 24

RE7MY13MW 24

RE7PD13BU 24

RE7PE11BU 24

RE7PM11BU 23

RE7PP13BU 24

RE7RA11BU 23

RE7RB11MW 24

RE7RB13MW 24

RE7RL13BU 23

RE7RM11BU 23

RE7TL11BU 24

RE7TM11BU 23

RE7TP13BU 24

RE7YA12BU 24

RE7YR12BU 24

RE8CL11BUTQ 25

RE8PD11BTQ 25

RE8PD11FUTQ 25

RE8PD21BTQ 25

RE8PD21FUTQ 25

RE8PD31BTQ 25

RE8PD31FUTQ 25

RE8PE11BUTQ 25

RE8PE21BUTQ 25

RE8PE31BUTQ 25

RE8PT01BUTQ 25

RE8RA11BTQ 25

RE8RA11FUTQ 25

RE8RA21BTQ 25

RE8RA21FUTQ 25

RE8RA31BTQ 25

RE8RA31FUTQ 25

RE8RA41FUTQ 25

RE8RB11BUTQ 25

RE8RB31BUTQ 25

RE8RB51BUTQ 25

RE8TA11BUTQ 25

RE8TA21BUTQ 25

RE8TA31BUTQ 25

RE8TA41BUTQ 25

RE8TA61BUTQ 25

RE8YA32BTQ 25

RE8YA32FUTQ 25

RE8YA32QTQ 25

RE8YG11BUTQ 25

RE8YG21BUTQ 25

RE8YG31BUTQ 25

RE9MS21MW 26

RE9RA11MW7 26

RE9RA21MW7 26

RE9RA31MW7 26

RE9RA51MW7 26

RE9TA11MW 26

RE9TA21MW 26

RE9TA31MW 26

RE9TA51MW 26

RE17LAMW 20

RE17LCBM 20

RE17LHBM 20

RE17LLBM 20

RE17LMBM 20

RE17RAMU 20

RE17RBMU 20

RE17RCMU 20

RE17RHMU 20

RE17RLJU 20

RE17RLMU 20

RE17RMEMU 20

RE17RMJU 20

RE17RMMU 20

RE17RMMW 20

RE17RMMWS 20

RE17RMXMU 20

RE22R1ACMR 21

RE22R1AKMR 21

RE22R1AMR 21

RE22R1CMR 21

RE22R1DMR 21

RE22R1HMR 21

RE22R1KMR 21

RE22R1MAMR 21

RE22R1MKMR 21

RE22R1MLMR 21

RE22R1MYMR 21

RE22R1QCMU 21

RE22R1QMQ 22

RE22R1QMU 22

RE22R2ACMR 21

RE22R2AMR 21

RE22R2AMU 22

RE22R2CMR 21

RE22R2DMR 21

RE22R2HMR 21

RE22R2KMR 21

RE22R2MJU 22

RE22R2MMU 22

RE22R2MMW 22

RE22R2MWMR 21

RE22R2MXMU 22

RE22R2MYMR 21

RE22R2QEMR 21

RE22R2QEMT 21

RE22R2QGMR 21

RE22R2QTMR 21

RE48ACV12MW 28

RE48AIPCOV 28

RE48AMH13MW 28

RE48AML12MW 28

RE48ASETCOV 28

RE48ASOC8SOLD 28

RE48ASOC11AR 28

RE48ASOC11SOLD 28

RE48ATM12MW 28

RE88857003 31

RE88857005 31

RE88857103 31

RE88857105 31

RE88857601 31

RE88857604 31

RE88857607 31

RE88857701 31

RE88857704 31

RE88857707 31

RE88867100 30

RE88867103 30

RE88867105 30

RE88867135 30

RE88867155 30

RE88867215 30

RE88867300 29

RE88867303 29

RE88867305 29

RE88867415 29

RE88867435 29

RE88867455 29

REXL2TMB7 27

REXL2TMBD 27

REXL2TMF7 27

REXL2TMJD 27

REXL2TMP7 27

REXL4TMB7 27

REXL4TMBD 27

REXL4TMF7 27

REXL4TMJD 27

REXL4TMP7 27

RUZC2M 28 30 31

RUZC3M 28 29 31

RXZE2M114 27

RXZE2M114M 27

RXZE2S108M 27

RXZE2S114M 27

RXZE2S114S 27

Page 34: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete
Page 35: Catalog August 2015 - Schneider Electric Automatyka przemyslowa/Przekazniki... · How can you fit a 6000-page catalog in your pocket ? Schneider Electric provides you with the complete

DIA

5ED

2130

103E

N

Head Office35, rue Joseph MonierF-92500 Rueil-MalmaisonFrance

www .schneider-electric .comSchneider Electric Industries SAS

August 2015-V4 .0

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein . This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein .

Design: Schneider ElectricPhotos: Schneider Electric