Main Catalogue Contactors Motor Protection Accessories 1SBC 0004 99 R1001 Low Voltage Products

Catálogo Completo Contatores

Embed Size (px)

Citation preview

  • Main Catalogue ContactorsMotor ProtectionAccessories

    1SBC 0004 99 R1001

    Low Voltage Products

  • Main Catalogue

    Contactors'

    Motor Protection'

    Accessories

  • Low Voltage Products1SBC 0004 99 R1001

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    Low Voltage Products

    As part of its on-going product improvement, ABB reserves the right to modify the characteristics of the products described in this catalogue.The information given is not contractual. For further details please contact the ABB company marketing these products in your country.

    Product Range

    A, AE, BC, EH, EK Contactors

    N and KC Contactor Relays

    Accessoriesfor A, AE, BC, EH, EK Contactorsand N, KC Contactor Relays

    TA and T Thermal O/L RelaysE Electronic O/L Relays

    General Technical DataStandards, Approvals

    Terminal Marking and PositioningStar-Delta Starter Diagrams

    Dimensions

    Reference IndexList of Addresses

    IEC

    VDE

    UTE

    H

    H

    H

    H

    H

    HH

    H

    H H

    H

    H H

    H

    H

    B(C) 6 and B(C) 7 Mini Contactors - Reversing ContactorsK(C) 6 Mini Contactor RelaysT 7 DU Thermal O/L Relay

  • 1SBC 0004 99 R1001Low Voltage Products

    Conformity with StandardsThe standards and specifications cited for different types of devices, e.g. IEC, BS, VDE, NFC, ENPublications, should be considered as statements of conformity in the sense of article 10 of theE.E.C. Low Voltage Directive of 19 February 1973.

    There is no label on ABB L.V. control apparatus identifying a national certification organization.The ABB logo figuring on devices, labels and documents certifies the conformity of devices withrespect to the applicable standards.

    CE marking is proof of conformity with the European Directives concerning the product. It mustnot be confused with a mark of quality.

    CE marking is part of an exclusively administrative procedure designed to guarantee the freemovement of the product inside the European Community.

    However, for some countries and some ship certification and classification organizations,certification is compulsory. In this case, the mark (or logo) of the given organization figures on thedevices if so required (see pages 7/4 and 7/5).

    Files pertaining to certifications and approvals obtained are available on request.

    LiabilityThe devices in this catalogue do not endanger safety when they are installed, mounted and usedaccording to their application and in compliance with the installation rules and standards whichapply to them.

    QualityABB has set up a quality assurance organisation in compliance with the requirements ofISO 9001 standard.ABB factories are ISO 9001 approved.

    ABB Low Voltage Products meet with a high quality standard. It is developed, manufactured andtested under the sole responsibility of ABB.

    In compliance with the regulations set out by the ISO 9000 series standard, ABB sets up andmanages the procedures and files relating to product quality and actions having an effect onquality.

    GuaranteeThe information contained in this catalogue reflects the current state of our knowledge and aimsto present our products and their possible applications. Thus, the information does not guaranteecertain specific characteristics of products or their aptitude for a specific utilization. All filed legalpatents or industrial property rights must be respected.

    Conformity with Standards,Liability, Quality andGuarantee

  • 1SBC 0004 99 R1001Low Voltage Products

    The currents given below concern standard, 1 500 r.p.m. 50 Hz, three-phase cage motors.These values are for your information and may vary according to the motor manufacturer and depending on the number of poles.

    Motor power motor nominal current at:220-230 V 240 V 380 V 415 V 440 V 500 V 600 V 660-690 V

    380-400 VkW PS = hp A A A A A A A A

    0.06 1/12 0.38 0.35 0.22 0.20 0.19 0.16 0.12 0.09 1/8 0.55 0.50 0.33 0.30 0.28 0.24 0.21 0.12 1/6 0.76 0.68 0.42 0.40 0.37 0.33 0.27 0.18 1/4 1.1 1 0.64 0.60 0.55 0.46 0.40 0.25 1/3 1.4 1.38 0.88 0.85 0.76 0.59 0.56 0.37 1/2 2.1 1.93 1.22 1.15 1.06 0.85 0.77 0.7 0.55 3/4 2.7 2.3 1.5 1.40 1.25 1.20 1.02 0.9 0.75 1 3.3 3.1 2 2 1.67 1.48 1.22 1.1 1.1 1.5 4.9 4.1 2.6 2.5 2.26 2.1 1.66 1.5 1.5 2 6.2 5.6 3.5 3.5 3.03 2.6 2.22 2 2.2 3 8.7 7.9 5 5 4.31 3.8 3.16 2.9 2.5 3.4 9.8 8.9 5.7 5.5 4.9 4.3 3.59 3.3 3 4 11.6 10.6 6.6 6.5 5.8 5.1 4.25 3.5 3.7 5 14.2 13 8.2 7.5 7.1 6.2 5.2 4.4 4 5.5 15.3 14 8.5 8.4 7.6 6.5 5.6 4.9 5 6.8 18.9 17.2 10.5 10 9.4 8.1 6.9 6 5.5 7.5 20.6 18.9 11.5 11 10.3 8.9 7.5 6.7 6.5 8.8 23.7 21.8 13.8 12.5 12 10.4 8.7 8.1 7.5 10 27.4 24.8 15.5 14 13.5 11.9 9.9 9 8 11 28.8 26.4 16.7 15.4 14.4 12.7 10.6 9.7 9 12.5 32 29.3 18.3 17 15.8 13.9 11.6 10.6 11 15 39.2 35.3 22 21 19.3 16.7 14.1 13 12.5 17 43.8 40.2 25 23 21.9 19 16.1 15 15 20 52.6 48.2 30 28 26.3 22.5 19.3 17.5 18.5 25 64.9 58.7 37 35 32 28.5 23.5 21 20 27 69.3 63.4 40 37 34.6 30.6 25.4 23 22 30 75.2 68 44 40 37.1 33 27.2 25 25 34 84.4 77.2 50 47 42.1 38 30.9 28 30 40 101 92.7 60 55 50.1 44 37.1 33 37 50 124 114 72 66 61.9 54 45.4 42 40 54 134 123 79 72 67 60 49.1 44 45 60 150 136 85 80 73.9 64.5 54.2 49 51 70 168 154 97 90 83.8 73.7 61.4 56 55 75 181 166 105 96 90.3 79 66.2 60 59 80 194 178 112 105 96.9 85.3 71.1 66 75 100 245 226 140 135 123 106 90.3 82 80 110 260 241 147 138 131 112 96.3 86 90 125 292 268 170 165 146 128 107 98100 136 325 297 188 182 162 143 119 107110 150 358 327 205 200 178 156 131 118129 175 420 384 242 230 209 184 153 135132 180 425 393 245 242 214 186 157 140140 190 449 416 260 250 227 200 167 145147 200 472 432 273 260 236 207 173 152160 220 502 471 295 280 256 220 188 170180 245 578 530 333 320 289 254 212 190184 250 590 541 340 325 295 259 217 200200 270 626 589 370 340 321 278 235 215220 300 700 647 408 385 353 310 260 235250 340 803 736 460 425 401 353 295 268257 350 826 756 475 450 412 363 302 280295 400 948 868 546 500 473 416 348 320315 430 990 927 580 535 505 445 370 337355 480 1080 1010 636 580 549 483 405 366400 545 1250 1130 710 650 611 538 450 410450 610 1410 1270 800 740 688 608 508 460475 645 1490 1340 850 780 730 645 540 485500 680 1570 1420 890 830 770 680 565 510560 760 1750 1580 1000 920 860 760 630 570600 810 1080 990 920 810 680 610670 910 1200 1100 1030 910 760 680

    Motor Nominal Powers andCurrents

    0/0

  • 1SBC 0004 99 R1001Low Voltage Products

    Coil Voltage Code forCompleting Order Codes

    A.C. Coils

    Types of contactors: CodeN, A 9 to A 110, GA 75UA 26 to UA 110 and UA16-R to UA75-R

    V (50 HZ) V (60 HZ) R nn n n . .24 24 8 126 28 1 628 32 1 742 42 8 242 48 2 048 48 8 360 60 7 3

    100 100 - 110 7 4105 110 - 127 2 6110 110 - 120 8 4

    110 - 115 115 - 127 8 9120 140 2 9

    125 - 127 150 3 0175 208 3 4190 220 3 6200 200 - 220 7 5210 240 4 0

    220 - 230 230 - 240 8 0230 - 240 240 - 260 8 8230 - 240 277 4 2380 - 400 400 - 415 8 5400 - 415 415 - 440 8 6

    400 440 5 0400 - 415 480 5 1415 - 440 440 - 460 8 7 (1)

    440 500 5 3500 600 5 5550 5 6

    660 - 690 5 8(1) Unsuitable for 3 or 4-pole A 45 - A 75 contactors.

    Standard voltages Code

    Types of contactors V (50 Hz) V (60 Hz) nn nnEH 145 - EH 300 24 A AEK 110 - EK 210 24 A B

    48 A C48 A D 110 A E

    110 120 A F127 A G

    208 A Z190 220 A H

    240 A KEH 145 - EH 800 220 - 230 * A LEK 110 - EK 550 230 - 240 A M

    380 A N380 - 400 440 A P400 - 415 A R

    480 A S440 A T500 A U

    600 A V* Read 240V 60Hz for EH 370 ... EH 800 and EK 370 ... EK 550.

    Dual frequency coils2 auxiliary contact blocks maximum per contactor, ambienttemperature 55C and mounting positions2 and 6 excluded.

    CodeTypes of contactors V (50 Hz) V (60 Hz) nn nn

    110 110 - 120 E FEH 145 110 - 115 115 - 127 E GEH 370 - EH 800 220 220 - 240 E LEK 370 - EK 550 220 - 230 230 - 255 E M

    380 380 - 415 E P380 - 400 400 - 440 E R

    0/1

    Multi-frequency coils CodeTypes of contactors V (40 - 400 Hz) nn nn

    110 - 120 E F115 - 127 E G

    EH 175 - EH 300 220 - 230 E LEK 110 - EK 210 230 - 240 E M

    380 - 400 E P400 - 415 E R

    Dual voltage coils for CodeN, A 9, A 12 and A 16 contactors

    V (50 HZ) V (60 HZ) R nn n n . .230/400 6 2

    230/400 6 3

    D.C. Coils

    Types of contactors:KC, BC - and AE -, GAE 75

    KC, BC - AE -, GAE 75V.d.c Code Code

    R nn . . nn R nn n n . .12 0 . . 7 8 024 0 . . 1 8 142 0 . . 2 8 248 1 . . 6 8 350 1 . . 7 2 160 0 . . 3 8 475 2 . . 2 8 5

    110 0 . . 4 8 6125 2 . . 7 8 7220 0 . . 5 8 8240 3 . . 3 8 9250 3 . . 4 3 8

    CodeTypes of contactors V d.c. nn nn

    12 (2) D A24 D B36 D C

    EH 145 - EH 800 48 D D60 D TEK 110 - EK 550 75 D G110 D E125 D U220 D F

    (2) Unsuitable for EH 370 - EH 800, EK 370 and EK 550 contactors.

  • 1SBC 0004 99 R1001Low Voltage Products

    General Data

    Ordering DetailsWhen placing an order give either the Order Code or Type.In most cases these are completed with other references, e.g. a contactor's coil voltage. This is why the order codes and types figuring in the "OrderingDetails" tables have boxes nn to be completed.

    Packagingl Individual standard packaging

    Contactors, contactor relays, thermal overload relays and other basic products are supplied in individual packaging. Some small contactors (e.g.B6 and B7 - Section 6) or accessories are in individual batches of "n" pieces as indicated in the "Packaging" column of the "Ordering Details"table.The weight and order code always correspond to a single part.Other products are supplied as a "set" and are thus marked in the "Packaging" column of the "Ordering Details" table. In this case, the weight andorder code correspond to a set.

    l Collective packagingTo limit the amount of wasted packaging, simplify handling and checking of deliveries, we offer the collective packaging solution.The weight and order code correspond to a single part.

    Products chosen for this type of packaging are detailed below.

    0/2

    Type Order code Product Packing Weightfeatures

    Clearly marked to be completed withcoil voltage: nn coil voltage: nn nnsee below See below See page : pieces kg

    4-pole - a.c. operated, 1 stack contactor relays

    N 22 E nn 1SBH 14 1001 T nn n n 22 3/6 10 0.34N 31 E nn 1SBH 14 1001 T nn n n 31 3/6 10 0.34N 40 E nn 1SBH 14 1001 T nn n n 40 3/6 10 0.34

    8-pole - a.c. operated, 2 stack contactor relays

    N 44 E nn 1SBH 14 1001 T nn n n 44 3/6 10 0.40N 53 E nn 1SBH 14 1001 T nn n n 53 3/6 10 0.40N 62 E nn 1SBH 14 1001 T nn n n 62 3/6 10 0.40N 71 E nn 1SBH 14 1001 T nn n n 71 3/6 10 0.40N 80 E nn 1SBH 14 1001 T nn n n 80 3/6 10 0.40

    3-pole - a.c. operated contactors

    A 9-30-10 nn 1SBL 14 1001 T nn n n 10 2/12 10 0.34A 9-30-01 nn 1SBL 14 1001 T nn n n 01 2/12 10 0.34A 9-30-22 nn 1SBL 14 1001 T nn n n 22 2/12 10 0.40A 9-30-32 nn 1SBL 14 1001 T nn n n 32 2/12 10 0.40A 12-30-10 nn 1SBL 16 1001 T nn n n 10 2/12 10 0.34A 12-30-01 nn 1SBL 16 1001 T nn n n 01 2/12 10 0.34A 12-30-22 nn 1SBL 16 1001 T nn n n 22 2/12 10 0.40A 12-30-32 nn 1SBL 16 1001 T nn n n 32 2/12 10 0.40A 16-30-10 nn 1SBL 18 1001 T nn n n 10 2/12 10 0.34A 16-30-01 nn 1SBL 18 1001 T nn n n 01 2/12 10 0.34A 16-30-22 nn 1SBL 18 1001 T nn n n 22 2/12 10 0.40A 16-30-32 nn 1SBL 18 1001 T nn n n 32 2/12 10 0.40A 26-30-10 nn 1SBL 24 1001 T nn n n 10 2/12 10 0.60A 26-30-01 nn 1SBL 24 1001 T nn n n 01 2/12 10 0.60

    4-pole - a.c. operated contactors

    A 9-40-00 nn 1SBL 14 1201 T nn n n 00 2/16 10 0.34A 16-40-00 nn 1SBL 18 1201 T nn n n 00 2/16 10 0.34A 26-40-00 nn 1SBL 24 1201 T nn n n 00 2/16 10 0.61

    Replacement coils for N, A 9, A 12 and A 16 contactors

    ZA 16 1SBN 15 1410 T nn n n 06 4/29 10 0.08

    Type Order code Product Packing Weightfeatures

    See page : pieces kg

    Auxiliary contact blocks

    CA 5-10 1SBN 01 0010 W1010 4/4 60 0.014CA 5-01 1SBN 01 0010 W1001 4/4 60 0.014CAL 5-11 1SBN 01 0020 W1011 4/4 100 0.050

    Interface block

    RA 5 1SBN 06 0000 T1000 4/16 10 0.050TE5S-24 1SBN 02 0010 T1001 4/6 10 0.080TE5S-120 1SBN 02 0010 T1002 4/6 10 0.080TE5S-240 1SBN 02 0010 T1003 4/6 10 0.080TE5S-440 1SBN 02 0010 T1004 4/6 10 0.080

    Additional code for coil voltages

    A.C. Voltages

    V (50 Hz) V (60 Hz) code nn nn . .24 24 8 142 42 8 248 48 8 3110 110 - 120 8 4

    110 - 115 115 - 127 8 9220 - 230 230 - 240 8 0230 - 240 240 - 260 8 8380 - 400 400 - 415 8 5400 - 415 415 - 440 8 6415 - 440 440 - 460 8 7

  • 11/11SBC 0004 99 R1001

    Low Voltage Products

    Product Range

    Contents

    Product Range PresentationBlock Contactors and O/L Relays ................................................................................... 1/2, 1/3Mini Contactors, Compact Reversing Contactors and O/L Relays ................................. 1/4, 1/5Contactor Relays and Mini Contactor Relays ........................................................................ 1/6

  • 1SBC 0004 99 R10011/2 Low Voltage Products

    Block Contactors Pages

    l 3-poleA, EH Contactors, a.c. operated 2/12, 2/13

    BC, AE, EH Contactors, d.c. operated 2/14, 2/15TBC, TAE Contactors d.c. operated, large coil voltage range 2/24AF Contactors, a.c./d.c. operated with controlled supply 2/27EHL Magnetically Latched Contactors, a.c. or d.c. operated 2/29

    l 4-poleA, EK Contactors, a.c. operated 2/16

    BC, AE, EK Contactors, d.c. operated 2/17TBC, TAE Contactors, d.c. operated, large coil voltage range 2/24AF Contactors, a.c./d.c. operated, with controlled supply 2/27EKL Magnetically Latched Contactors, a.c. or d.c. operated 2/29

    l 3-poleUA Contactors, a.c. operated 2/21

    UA..-R Contactors, a.c. operated 2/22

    A, EH Contactors, a.c. operated 2/12, 2/13

    l 1-poleGA Contactor, a.c. operated 2/28

    GAE Contactor, d.c. operated 2/28

    l 3-poleA, EH Contactors, a.c. operated 2/46, 2/47

    BC, AE, EH Contactors, d.c. operated 2/462/48

    l 4-poleA, EK Contactors, a.c. operated 2/46, 2/47

    BC, AE, EK Contactors, d.c. operated 2/462/48

    Product Range PresentationBlock Contactors

    Section 2

    a.c. circu

    it

    switchin

    ga.c. circu

    it

    switchin

    g

    3-phase c

    apacitor

    switchin

    g3-ph

    ase capac

    itor

    switchin

    g

    d.c. circu

    it

    switchin

    gd.c. circu

    it

    switchin

    g

    Applicati

    ons

    Applicati

    ons

  • 11/31SBC 0004 99 R1001

    Low Voltage Products

    Product Range PresentationBlock ContactorsOverload Relays

    Block Contactors Pages

    l 3-poleA Contactors, a.c. operated 2/44, 2/45

    AE Contactors, d.c. operated 2/44, 2/45

    l 4-poleA Contactors, a.c. operated 2/44, 2/45

    AE Contactors, d.c. operated 2/44, 2/45

    l 3-poleA, EH Contactors, a.c. operated 2/49

    AE, EH Contactors, d.c. operated 2/49

    l 3-poleA, EH Contactors, a.c. operated 2/50, 2/51

    Overload Relays Pages

    l 3-poleE 16 DU Electronic O/L Relay 5/19

    T, TA Thermal O/L Relays 5/45/6

    Section 2

    Section 5

    Applicati

    ons

    Applicati

    ons

    lighting c

    ircuit

    switchin

    glighting c

    ircuit

    switchin

    g

    3-phase

    transfor

    mer

    switchin

    g3-ph

    ase

    transfor

    mer

    switchin

    g

    3-phase

    slip-ring

    motor

    switchin

    g3-ph

    ase

    slip-ring

    motor

    switchin

    g

    Motor

    protectio

    nMotor

    protectio

    n

  • 1SBC 0004 99 R10011/4 Low Voltage Products

    Section 6

    Product Range PresentationMini Contactors, Compact Reversing Contactors

    Mini Contactors,Compact Reversing Contactors Pages

    l 3-poleB 6, B 7 Mini Contactors, a.c. operated 6/2

    BC 6, BC 7 Mini Contactors, d.c. operated 6/2TBC 7 Mini Contactors, d.c. operated, large coil voltage range 6/8

    l 4-poleB 6, B 7 Mini Contactors, a.c. operated 6/2

    l 3-poleVB 6, VB 7 Compact Reversing Contactors, a.c. operated 6/3VB 6A, VB 7A Compact Reversing Contactors, a.c. operated 6/4

    VBC 6, VBC 7 Compact Reversing Contactors, d.c. operated 6/3VBC 6A, VBC 7A Compact Reversing Contactors, d.c. operated 6/4

    Mini Contactors,Compact Reversing Contactors Pages

    l 3-poleB 6, B 7 Mini Contactors, a.c. operated 6/11

    BC 6, BC 7 Mini Contactors, d.c. operated 6/11

    l 4-poleB 6, B 7 Mini Contactors, a.c. operated 6/11

    l 3-poleVB 6, VB 7 Compact Reversing Contactors, a.c. operated 6/11

    VBC 6, VBC 7 Compact Reversing Contactors, d.c. operated 6/11

    Section 6

    d.c. circu

    it

    switchin

    gd.c. circu

    it

    switchin

    g

    a.c. circu

    it

    switchin

    ga.c. circu

    it

    switchin

    g

    Applicati

    ons

    Applicati

    ons

  • 11/51SBC 0004 99 R1001

    Low Voltage Products

    Product Range PresentationMini Contactors, Compact Reversing ContactorsOverload Relay

    Section 6

    Section 6

    lighting c

    ircuit

    switchin

    glighting c

    ircuit

    switchin

    g

    Motor

    protectio

    nMotor

    protectio

    n

    Applicati

    ons

    Applicati

    ons

    PLC's Ou

    tput

    PLC's Ou

    tput

    Interface

    Interface

    Mini Contactors,Compact Reversing Contactors Pages

    l 3-poleB 6, B 7 Mini Contactors, a.c. operated 6/12

    BC 6, BC 7 Mini Contactors, d.c. operated 6/12

    l 4-poleB 6, B 7 Mini Contactors, a.c. operated 6/12

    l 3-poleVB 6, VB 7 Compact Reversing Contactors, a.c. operated 6/12

    VBC 6, VBC 7 Compact Reversing Contactors, d.c. operated 6/12

    l 3-poleBC 6, BC 7 Interface Mini Contactors, d.c. operated 6/5

    l 3-poleB 6S, B 7S Mini Contactors for PLC's Output, d.c. operated 6/5

    Overload Relay Pages

    l 3-poleT 7 DU Thermal Overload Relay 6/17

  • 1SBC 0004 99 R10011/6 Low Voltage Products

    Section 6

    Product Range PresentationContactors RelaysMini Contactor Relays

    Applicati

    ons

    Applicati

    ons Section 3 Contactor Relays Pages

    l 4-poleN Contactor Relays, a.c. operated 3/6

    KC Contactor Relays, d.c. operated 3/6

    TKC Contactor Relays, d.c. operated, large coil voltage range 3/7

    l 8-poleN Contactor Relays, a.c. operated 3/6

    KC Contactor Relays, d.c. operated 3/6

    TKC Contactor Relays, d.c. operated, large coil voltage range 3/7

    Mini Contactor Relays Pages

    l 4-poleK 6 Mini Contactor Relays, a.c. operated 6/6

    KC 6 Mini Contactor Relays, d.c. operated 6/6KC 6 Interface Mini Contactor Relays, d.c. operated 6/6K 6S Mini Contactor Relay for PLC's Output, d.c. operated 6/6

    Control c

    ircuit

    switchin

    gControl c

    ircuit

    switchin

    g

    Control c

    ircuit

    switchin

    gControl c

    ircuit

    switchin

    g

  • 2/11SBC 0004 99 R1001

    Low Voltage Products

    2

    A, AE, BC, EH and EKContactorsRatings 9 to 800 A

    Contents

    Selection Tables

    A and EH 3-pole Contactors ................................................................................................. 2 /2A and EK 4-pole Contactors ............................................................................................... 2 /4Star-delta Starting ............................................................................................................. 2 /31

    Description and Mounting of AccessoriesA and AE Contactors .......................................................................................................... 2 /6EH and EK Contactors ........................................................................................................ 2 /8BC Contactors ................................................................................................................... 2 /10

    Ordering DetailsA 3-pole Contactors - A.C. Operated ................................................................................ 2/12EH 3-pole Contactors - A.C. Operated ............................................................................. 2 /13BC 3-pole Contactors - D.C. Operated ............................................................................. 2 /14AE and EH 3-pole Contactors - D.C. Operated ................................................................ 2 /15A and EK 4-pole Contactors - A.C. Operated ................................................................... 2 /16BC, AE and EK 4-pole Contactors - D.C. Operated .......................................................... 2 /17A 4-pole Contactors with N.O. and N.C. Main Poles - A.C. Operated .............................. 2 /18BC and AE 4-pole Contactors with N.O. and N.C. Main Poles - D.C. Operated ............... 2 /193-pole Contactors for 3-phase Capacitor Switching - A.C. Operated ................................ 2 / 20 UA 3-pole contactors .................................................................................................... 2 / 21 UA..-R 3-pole contactors ............................................................................................... 2 / 22TBC and TAE Contactors - D.C. Operated with Large Coil Voltage Range ..................... 2 /24AF Contactors with Controlled Supply A.C./D.C. Operated .............................................. 2 /26GA 75 and GAE 75 Contactors for D.C. Circuit Switching ................................................ 2 /28EHL and EKL Magnetically Latched Contactors - A.C./D.C. Operated ............................. 2 /29EH Mechanically Interlocked or Mechanically Latched Contactors .................................. 2 /30

    Technical Data

    A, EH and EK Contactors - A.C. Operated ....................................................................... 2 /32BC, AE and EH, EK Contactors - D.C. Operated .............................................................. 2 /38Lighting Circuit Switching .................................................................................................. 2 /44D.C. Circuit Switching ......................................................................................................... 2 /46LV/LV 3-phase Transformer Switching ............................................................................. 2 /49Control of 3-phase Slip-ring Motors .................................................................................... 2 /50Influence of the Length of Conductors Used in Contactor Control Circuit ........................ 2 /52Parallel Connection of Main Poles - Temporary or Intermittent Duty ................................ 2 /54Contactor Utilization Categories and Electrical Durability ................................................. 2 /55

    Additional Information

    Accessories and Coils ............................................................................................... Section 4General Technical Data, Approvals and Classifications ........................................... Section 7Terminal Marking and Positioning ............................................................................. Section 8Dimensions ............................................................................................................... Section 9

  • Low Voltage Products1SBC 0004 99 R10012/2

    3-pole contactors Type A 9 A 12 A 16 A 26 A 30 A 40 A 50 A 63 A 75

    Rated operational power AC-3 (1) 55 C (2)220-230-240 V kW 2.2 3 4 6.5 9 11 15 18.5 22

    380-400 V kW 4 5.5 7.5 11 15 18.5 22 30 37415 V kW 4 5.5 9 11 15 18.5 25 37 40440 V kW 4 5.5 9 15 18.5 22 25 37 40500 V kW 5.5 7.5 9 15 18.5 22 30 37 45690 V kW 5.5 7.5 9 15 18.5 22 30 37 40

    1000 V kW - - - - - - 30 33 37

    Rated operational current Ie /AC-3 (1) 55 C (2)220-230-240 V A 9 12 17 26 33 40 53 65 75

    380-400 V A 9 12 17 26 32 37 50 65 75415 V A 9 12 17 26 32 37 50 65 72440 V A 9 12 16 26 32 37 45 65 70500 V A 9 12 14 22 28 33 45 55 65690 V A 7 9 10 17 21 25 35 43 46

    1000 V A - - - - - - 23 25 28

    Rated operational current Ie /AC-1 - Ue max. 690V 40 C (2) A 25 27 30 45 55 60 100 115 125 55 C (2) A 22 25 27 40 55 60 85 95 105 70 C (2) A 18 20 23 32 39 42 70 80 85

    with conductor cross-sectional area mm2 2.5 4 4 6 10 16 35 50 50

    Short-circuit protection for contactors withoutadd-on thermal O/L relays - Motor protection excluded (3)Ue 500 V a.c. - gG (gI) max. fuses A 25 32 32 50 63 63 100 125 160Coil consumptionAverage pull-in value - 50 Hz VA 70 120 180

    - 60 Hz VA 80 140 210- 50/60 Hz (4) VA/VA 74/70 125/120 190/180

    Average holding value - 50 Hz VA/W 8/2 12/3 18/5.5- 60 Hz VA/W 8/2 12/3 18/5.5- 50/60 Hz (4) VA/W 8/2 12/3 18/5.5

    Mechanical durabilityin millions of operating cycles 10

    Electrical durability for Ie /AC-3 max.in millions of operating cycles 1.5

    Thermal O/L relays Type TA 25 DU TA 75 DUSetting range A 0.1 - 32 18 - 80

    Type TA 42 DUSetting range A 18 - 42

    TA 25 DU TA 42 DU TA 75 DU

    (1) For the corresponding kW/hp/A value of 1500 r.p.m., 50 Hz, 3-phase motors, refer to page 0/0. (2) Temperature close to contactor.(3) For short-circuit protection of motor starters, see page 7/17 (4) 50/60 Hz coils: voltage codes nn nn to nn nn , see page 0/1.

    Other technical information: page 2/32.

    1500 r.p.m. - 50 Hzor 1800 r.p.m. - 60 Hz3-phase Motors

    3-phase Motors

    8 0 8 8

    A and EH 3-pole Contactors - A.C. OperatedTA and T Thermal O/L RelaysSelection Table

  • 2/31SBC 0004 99 R1001

    Low Voltage Products

    2

    A and EH 3-pole Contactors - A.C. OperatedTA and T Thermal O/L RelaysSelection Table

    3-pole contactors Type A 95 A 110 EH 145 EH 175 EH 210 EH 260 EH 300 EH 370 EH 550 EH 700 EH 800

    Rated operational power AC-3 (1) 55 C (2) 220-230-240 V kW 25 30 45 55 59 80 90 110 160 220 220

    380-400 V kW 45 55 75 90 110 140 160 200 280 370 400415 V kW 55 59 75 90 110 140 160 220 315 400 425440 V kW 55 59 75 90 110 140 160 220 315 400 450500 V kW 55 59 90 110 132 180 200 250 400 480 520690 V kW 55 75 110 132 160 200 250 355 500 600 650

    1000 V kW 40 40 110 132 160 180 200 220 250 315 315

    Rated operational current Ie /AC-3 (1) 55 C (2) 220-230-240 V A 96 110 150 185 210 260 305 400 550 700 750

    380-400 V A 96 110 145 185 210 260 305 400 550 700 750415 V A 96 110 145 185 210 260 300 400 550 700 720440 V A 93 100 145 185 210 240 280 370 550 700 720500 V A 80 100 145 170 210 240 280 370 550 700 720690 V A 65 82 120 170 210 220 280 370 550 700 720

    1000 V A 30 30 80 94 113 125 140 155 175 220 220Rated operational current Ie /AC-1Ue max. 690 V 40 C (2) A 145 160 230 260 300 400 445 550 800 1000 1000

    55 C (2) A 135 145 200 230 270 340 375 470 650 800 800 70 C (2) A 115 130 160 170 215 290 325 400 575 720 720

    with conductor cross-sectional area mm2 50 70 120 150 185 300 300 2 x 185 2 x 240 2 x 300 2 x 300

    gG (gI) max. fuses A 160 200 250 355 355 500 500 630 800 1000 1000Coil consumptionAverage pull-in value - 50 Hz VA 350 430 800 1100 2600 3500

    - 60 Hz VA 450 490 900 1200 2900 4000- 50/60 Hz (4)VA/VA 410/365 460/400 500 630 2800/2450 3800/3400

    Average holding value - 50 Hz VA/W 22/6.5 30/11 44/15 52/18 90/36 125/50- 60 Hz VA/W 26/8 35/12 52/18 65/22 105/44 140/60- 50/60 Hz (4) VA/W 27/7.5 38/12 2.5/2.5 2.5/2.5 100/47 140/60

    Mechanical durabilityin millions of operating cycles 10 10 5

    Electrical durability Ie /AC- 3 max.in millions of operating cycles > 1 > 1 > 0.6 > 0.5

    Thermal O/L relays Type TA 80 DU T 200 DU T 900 DU/SUSetting range A 29 - 80 100 - 200 265 - 850

    Type TA 110 DU T 450 DU/SUSetting range A 65 - 110 130 - 400

    TA 80 DU TA 110 DU T 200 DU T 450 DU T 900 DU

    (1) For the corresponding kW/hp/A value of 1500 r.p.m., 50 Hz, 3-phase motors, refer to page 0/0. (2) Temperature close to contactor.(3) For short-circuit protection of motor starters, see page 7/17 (4) 50/60 Hz coils: voltage codes nn nn to nn nn and E nn , see page 0/1.

    please consult co-ordination tables (ref. ITSCB 649171/002 9-1996).Other technical information: page 2/33.

    8 0 8 8

  • Low Voltage Products1SBC 0004 99 R10012/4

    4-pole contactors Type A 9 A 16 A 26 A 45 A 50 A 75Rated operational voltage Ue max. V 690 690 690

    Rated operational current Ie /AC-1 40 C (1) A 25 30 45 70 100 125 55 C (1) A 22 27 40 60 85 105 70 C (1) A 18 23 32 50 70 85

    with conductor cross-sectional area mm2 2.5 4 6 25 35 50

    Short-circuit protection for contactors withoutthermal O/L relays - Motor protection excludedUe 500V a.c. - gG (gI) max. fuses A 25 32 50 80 100 160Coil consumptionAverage pull-in value - 50 Hz VA 70 120 180

    - 60 Hz VA 80 140 210- 50/60 Hz (2) VA/VA 74/70 125/120 190/180

    Average holding value - 50 Hz VA/W 8/2 12/3 18/5.5- 60 Hz VA/W 8/2 12/3 18/5.5- 50/60 Hz (2) VA/W 8/2 12/3 18/5.5

    Mechanical durabilityin millions of operating cycles 10

    Electrical durability for Ie /AC-1 max.in millions of operating cycles See curves page 2/56(1) Temperature close to contactor.(2) 50/60 Hz coils: voltage codes nn nn to nn nn , see page 0/1.

    Other technical information: page 2/32.

    A and EK 4-pole Contactors - A.C. OperatedSelection Table

    8 0 8 8

  • 2/51SBC 0004 99 R1001

    Low Voltage Products

    2

    A and EK 4-pole Contactors - A.C. OperatedSelection Table

    Type EK 110 EK 150 EK 175 EK 210 EK 370 EK 550Ue max. V 690

    Rated operational current Ie /AC-1 40 C (1) A 200 250 300 350 550 800 55 C (1) A 180 230 270 310 470 650 70 C (1) A 155 200 215 250 400 575

    with conductor cross-sectional area mm2 95 150 185 240 2 x 185 2 x 240

    gG (gI) max. fuses A 250 355 630 800Coil consumptionAverage pull-in value - 50 Hz VA 800 1100 3500 3500

    - 60 Hz VA 900 1200 4000 4000- 50/60 Hz (2)VA/VA 500 630 3800/3400 3800/3400

    Average holding value - 50 Hz VA/W 44/15 52/18 125/50 125/50- 60 Hz VA/W 52/18 65/22 140/60 140/60- 50/60 Hz (2) VA/W 2.5/2.5 2.5/2.5 140/60 140/60

    Mechanical durabilityin millions of operating cycles 5

    Electrical durability for Ie /AC-1 max.in millions of operating cycles See curves page 2/56(1) Temperature close to contactor.(2) 50/60 Hz coils: voltage codes E nn , see page 0/1.

    Other technical information: page 2/33.

  • Low Voltage Products1SBC 0004 99 R10012/6

    ApplicationA contactors are mainly used for controlling 3-phase motors and generally speaking for controlling power circuits corresponding to their operatingcharacteristics up to 690 and even 1000 V a.c. and 440 V d.c.

    Description of 3-pole and 4-pole contactors: A 9 - A 110All A and AE contactors can be assembled side by side.The add-on or built-in auxiliary contacts are suitable for low level currents.When fitted with a 4-pole CA5 auxiliary contact block, A9 - A16 2-stack or 1-stack contactors ensure positive safety between their auxiliary contacts.

    l Control circuit variants: A contactors: a.c. operated with laminated magnetic circuit. AE contactors: with laminated magnetic circuit and double-winding coil fed from d.c. supply via a CDL5 insertion contact mounted on the device.

    The CDL5 has an N.C. lagging contact for insertion of the second winding.

    l Contact variants: 3-pole contactors - with N.O. or N.C. built-in auxiliary contact for A 9 - A 40 contactors.

    - with or without side-mounted, factory-assembled auxiliary contacts for A 50 - A 110 contactors. 4-pole contactors: 4-pole make or 2-pole make and 2-pole break without mounted auxiliary contacts. 3-pole/2-stack contactors: the first stack is made of a standard 3-pole contactor and the second stack of an irremovable 4-pole auxiliary contact

    block. The width does not exceed that of the 1-stack contactor, only the depth is increased.

    l Contactors for specific applications: UA and UA..-R types for 3-phase capacitor switching. GA and GAE types for d.c. circuit switching. TAE d.c. operated type with large coil voltage range. AF a.c. and d.c. operated type with controlled supply.

    A and AE ContactorsDescription

    A 9 - A 110

    l Ordering Details ......................................................... pages 2/12, 2/16 l General - Approvals .............................................................. Section 7l Technical Data ....................................................................... page 2/32 l Terminal Marking and Positioning ....................................... Section 8l Accessories ............................................................................ Section 4 l Dimensions ............................................................................. Section 9

    Location of surge suppressors

    Terminals delivered in open position with captivescrews (screws of unused terminals must be tightened).Screwdriver guidance for all terminals makes itpossible to use motorized screwdrivers.All terminals provide protection against accidentaldirect contact with live parts according toVDE 0106 - Part. 100.All A 9 - A 40 contactor terminals as well asA 45 - A 110 contactor auxiliary contact and coilterminals ensure IP 20 degree of protection accordingto IEC 947-1.

    Location of side-mounted accessories: on right or lefthand side. Factory-mounted on: left hand side for CAL5 on A 50 - A 110-30-11, right hand side for CDL5/CCL5 on AE 45 - AE 110.

    Quick fixing on mounting rail according to IEC 715,EN 50022 and EN 50023 standards:35 x 7.5 mm for A 9 - A 40,35 x 15 mm for A 9 - A 75,75 mm for A 45 - A 110.

    Holes for screw fixing (screws not supplied).Distance between holes according toEN 50003 (contactors for 11 kW motors).

    Terminal screws: Pozidriv (+,-) N 2 for all A9 - A 40 terminals and

    for A 45 - A 110 coil terminals. M8 screws with 6.5 mm slot for A 45 - A 75 main

    terminals. HC, M8 for A 95/110 main terminals.

    Terminal marking according to IEC 947-4-1,EN 50005, EN 50012 and NEMA standards.

    Connecting point for control leads in top part ofmain terminals of A 45 - A 75 contactors.

    Clear marking of coil voltages and frequencies.

    Location of function marker.

    Stops for attaching front-mounted accessories.

  • 2/71SBC 0004 99 R1001

    Low Voltage Products

    2

    A and AE ContactorsAccessories and Thermal O/L Relays

    * Use electronic timer TE 5S (page 4/6) with A(E) 95 and A(E) 110 contactors.

    The same accessories can be added on to A 9, A 16, A 26, A 45, A50 and A 75 4-pole contactors as 3-pole contactors.

  • Low Voltage Products1SBC 0004 99 R10012/8

    ApplicationEH 3-pole contactors are mainly used for controlling 3-phase motors and generally speaking for controlling power circuits corresponding to theiroperating characteristics up to voltages of 1000 V a.c. and 440 V d.c.EK 4-pole contactors are mainly used for controlling back-up circuits and all distribution circuits where the neutral needs to be broken.

    Description of EH 145 - EH 800 and EK 110 - EK 550 contactorsl One N.O. + N.C. auxiliary contact block is fitted to the left hand side of 3-pole and 4-pole contactors. (Three other auxiliary contact blocks can be added). Complete

    closing is ensured, even at the lowest control voltage, by a patented spring system. The coil is compound-filled in heat-resistant, glass-fibrereinforced resin. Exact ordering and marking details are automatically obtained when the coil is changed.

    l EH 3-pole contactors and EK 4-pole contactors can be supplied: with a laminated magnetic circuit and a coil fed directly from an a.c. current supply for a.c. control with a laminated magnetic circuit and a coil fed from a d.c. current supply across an economy resistor connected via an auxiliary contact block

    comprising an N.C. lagging contact for d.c. control.

    l Ordering Details ........................................................... pages 2/13, 2/15, 2/16 l General - Approvals ......................................................... Section 7l Technical Data ....................................................................... pages 2/33, 2/39 l Terminal Marking and Positioning ................................. Section 8l Accessories ....................................................................................... Section 4 l Dimensions ....................................................................... Section 9

    Separate arcing contacts for EH 370 - EH 800.

    Main contacts with high-conductivityand low-oxidation coating.

    Terminal marking according to IEC 947-4-1,EN 50005, EN 50012 and NEMA. Clearly markedmain terminals and phase conductors.

    Plain holes for M4 screws(auxiliary circuit wires).

    M10 earth screw for EH 370 - 800. Can also befitted at the bottom.

    Screw, nut and washer supplied for every main terminal.Connectors for either copper or aluminium can besupplied separately.

    EH 145 - EH 800

    Separate arcing contacts for EH 370 - EK 550.

    Main contacts with high-conductivityand low-oxidation coating.

    Terminal marking according to IEC 947-4-1,EN 50005, EN 50012 and NEMA. Clearly markedmain terminals and phase conductors.

    Clearly marked coil voltage and frequency. Terminalsprovide protection against accidental contact with liveparts (IP 20).

    M 10 earth screw for EK 370 and EK 550.Can also be fitted at the bottom.

    Screw, nut and washer supplied for every mainterminal.Connectors for either copper or aluminium can besupplied separately.

    EK 110 - EK 550

    Clearly marked coil voltage and frequency. Terminalsprovide protection against accidental contact with liveparts (IP 20).

    Plain holes for M4 screws(auxiliary circuit wires).

    Removable coil for EH 175 - EH 300.The coil can be changed on the contactor installed.

    Removable coil for EK 110 - EK 210.The coil can be changed on the contactor installed.

    EH and EK ContactorsDescription

    Glass-fibre reinforced polyester arc chute.

    Quick-release clip for access to arc chute.

    Terminals protected against accidental contactwith live parts (IP 20).

    Auxiliary contact block supplied.

    High quality plastic case for EH 145 - 300 andmoulded light alloy case for EH 370 - 800.

    Dampers for EH 370 - 800 are supplied withscrews and washers.

    Quick-release clip for arc chutes.

    Glass-fibre reinforced polyester arc chute.

    Dampers for EK 370 and 550 are supplied withscrews and washers.

    Terminals protected against accidental directcontact with live parts (IP 20).

    Auxiliary contact block supplied.

  • 2/91SBC 0004 99 R1001

    Low Voltage Products

    2

    The same accessories can be added on to EK 4-pole contactors as EH 3-pole contactors.

    EH and EK ContactorsAccessories and Thermal O/L Relays

  • Low Voltage Products1SBC 0004 99 R10012/10

    ApplicationBC contactors are mainly used for controlling 3-phase motors and generally speaking for controlling power circuits corresponding to their operatingcharacteristics up to 690 V a.c. and 440 V d.c.

    Description of 3-pole or 4-pole contactors: BC 9 - BC 30For BC and TBC type contactors make sure that the mounting distance specified in the "Ordering Details" pages 2/14, 2/17, 2/19 and 2/24 isrespected for "side by side" (position 1) and "stacked" (positions 3 and 4) mounting.The add-on or built-in auxiliary contacts are suitable for low level currents.BC 9, BC 16, TBC 9 and TBC 16 2-stack or 1-stack contactors fitted with a 4-pole CA5 auxiliary contact block ensure positive safety between theirauxiliary contacts.

    l Type of magnetic circuit: Solid magnetic circuit with d.c. fed coil.

    l Contact variants: 3-pole contactors with built-in N.O. or N.C. auxiliary contact for BC 9 - BC 25 contactors. 4-pole contactors: 4-pole make or 2-pole make and 2-pole break without built-in auxiliary contacts. 2-stack 3-pole contactors: the first stack is made of a standard contactor and the second stack of an irremovable 4-pole auxiliary contact block.

    The width does not exceed that of the 1-stack contactor, only the depth is increased.

    l Contactors for specific applications: D.C. operated TBC - types with large voltage range. Variants specific to traction are not given in this catalogue. Please consult us.

    BC ContactorsDescription

    Stops for attaching front-mounted accessories.

    Clear marking of coil d.c. voltage.

    Terminal marking according to IEC 947-4-1,EN 50005, EN 50012 and NEMA standards.

    Quick fixing on mounting rail according to IEC 715and EN 50022 standards: 35 x 7.5 mm, 35 x 15 mm.

    Location of function marker.

    Dove tail anchoring for surge suppressorassembly.

    BC 9 - BC 30

    Terminals delivered in open position with captivescrews (screws of unused terminals must be tightened).Screwdriver guidance for all terminals makes itpossible to use motorized screwdrivers.All terminals provide protection against accidentaldirect contact with live parts according toVDE 0106 - Part. 100.

    Holes for screw fixing (screws not supplied).Distance between holes according toEN 50003 (contactors for 11 kW motors).

    Terminal screw types: Pozidriv (+,-) N 2; M 3.5 for all BC 9 and BC 16

    terminals and BC 18 - BC 30 coil terminals. Pozidriv (+,-) N 2; M 4 for BC 18 and BC 25 main

    terminals. Pozidriv (+,-) N 2; M 5 for BC 30 main terminals.

    l Ordering Details .................................................... pages 2/14, 2/17, 2/19, 2/24 and 2/25 l General - Approvals .................................................................. Section 7l Technical Data .................................................................................................. page 2/38 l Terminal Marking and Positioning .......................................... Section 8l Accessories ....................................................................................................... Section 4 l Dimensions ............................................................................... Section 9

  • 2/111SBC 0004 99 R1001

    Low Voltage Products

    2

    The same accessories can be added on to BC 9, BC 16 and BC 25 4-pole contactors as 3-pole contactors.* For selection and use of surge suppressors, see notes page 4/14.

    BC ContactorsAccessories and Thermal O/L Relays

  • Low Voltage Products1SBC 0004 99 R10012/12

    Type Order code Mounted aux.contacts Rated operational Motor power AC-3 WeightState coil to be completed with coil 1st stack 2nd stack voltage 220 V 380 V in kgvoltage: n n voltage code: n nn n AC-1 AC-3 230 V 400 V 415 V 690 V

    40C 400 V 240 V PackingSee page 0/1 See page 0/1 A A kW kW kW kW 1 piece

    A 9-30-10 nn 1SBL 14 1001 R n n n n 10 1 25 9 2.2 4 4 5.5 0.34A 9-30-01 n n (1) 1SBL 14 1001 R n n n n 01 1 25 9 2.2 4 4 5.5 0.34A 9-30-22 nn 1SBL 14 1001 R n n n n 22 2 2 25 9 2.2 4 4 5.5 0.40A 9-30-32 nn 1SBL 14 1001 R n n n n 32 1 2 2 25 9 2.2 4 4 5.5 0.40

    A 12-30-10 nn 1SBL 16 1001 R n n n n 10 1 27 12 3 5.5 5.5 7.5 0.34A 12-30-01 n n (1) 1SBL 16 1001 R n n n n 01 1 27 12 3 5.5 5.5 7.5 0.34A 12-30-22 nn 1SBL 16 1001 R n n n n 22 2 2 27 12 3 5.5 5.5 7.5 0.40A 12-30-32 nn 1SBL 16 1001 R n n n n 32 1 2 2 27 12 3 5.5 5.5 7.5 0.40

    A 16-30-10 nn 1SBL 18 1001 R n n n n 10 1 30 17 4 7.5 9 9 0.34A 16-30-01 n n (1) 1SBL 18 1001 R n n n n 01 1 30 17 4 7.5 9 9 0.34A 16-30-22 nn 1SBL 18 1001 R n n n n 22 2 2 30 17 4 7.5 9 9 0.40A 16-30-32 nn 1SBL 18 1001 R n n n n 32 1 2 2 30 17 4 7.5 9 9 0.40

    A 26-30-10 nn 1SBL 24 1001 R n n n n 10 1 45 26 6.5 11 11 15 0.60A 26-30-01 nn 1SBL 24 1001 R n n n n 01 1 45 26 6.5 11 11 15 0.60A 26-30-32 nn 1SBL 24 1001 R n n n n 32 1 2 2 45 26 6.5 11 11 15 0.66

    A 30-30-10 nn 1SBL 28 1001 R n n n n 10 1 55 32 9 15 15 18.5 0.71A 30-30-01 nn 1SBL 28 1001 R n n n n 01 1 55 32 9 15 15 18.5 0.71A 30-30-32 nn 1SBL 28 1001 R n n n n 32 1 2 2 55 32 9 15 15 18.5 0.77

    A 40-30-10 nn 1SBL 32 1001 R n n n n 10 1 60 37 11 18.5 18.5 22 0.71A 40-30-01 nn 1SBL 32 1001 R n n n n 01 1 60 37 11 18.5 18.5 22 0.71A 40-30-32 nn 1SBL 32 1001 R n n n n 32 1 2 2 60 37 11 18.5 18.5 22 0.77

    A 50-30-00 nn 1SBL 35 1001 R n n n n 00 100 50 15 22 25 30 1.16A 50-30-11 nn 1SBL 35 1001 R n n n n 11 1 1 100 50 15 22 25 30 1.20A 50-30-22 nn 1SBL 35 1001 R n n n n 22 2 2 100 50 15 22 25 30 1.23

    A 63-30-00 nn 1SBL 37 1001 R n n n n 00 115 65 18.5 30 37 37 1.16A 63-30-11 nn 1SBL 37 1001 R n n n n 11 1 1 115 65 18.5 30 37 37 1.20A 63-30-22 nn 1SBL 37 1001 R n n n n 22 2 2 115 65 18.5 30 37 37 1.23

    A 75-30-00 nn 1SBL 41 1001 R n n n n 00 125 75 22 37 40 40 1.16A 75-30-11 nn 1SBL 41 1001 R n n n n 11 1 1 125 75 22 37 40 40 1.20A 75-30-22 nn 1SBL 41 1001 R n n n n 22 2 2 125 75 22 37 40 40 1.23

    A 95-30-00 nn 1SFL 43 1001 R n n n n 00 145 96 25 45 55 55 2.00A 95-30-11 nn 1SFL 43 1001 R n n n n 11 1 1 145 96 25 45 55 55 2.04A 95-30-22 nn 1SFL 43 1001 R n n n n 22 2 2 145 96 25 45 55 55 2.07

    A 110-30-00 nn 1SFL 45 1001 R n n n n 00 160 110 30 55 59 75 2.00A 110-30-11 nn 1SFL 45 1001 R n n n n 11 1 1 160 110 30 55 59 75 2.04A 110-30-22 nn 1SFL 45 1001 R n n n n 22 2 2 160 110 30 55 59 75 2.07

    (1) In mounting position 5, do not use more than 2 front-mounted N.C. auxiliary contacts.The CAL 5-11 side-mounted blocks provide additional N.C. contacts.

    l Technical Data ...................................................... page 2/32 l General - Approvals .............................................. Section 7l Accessories ........................................................... Section 4 l Terminal Marking and Positioning ...................... Section 8l Thermal O/L Relays .............................................. Section 5 l Dimensions ............................................................ Section 9

    SB 7

    312S

    2SB

    731

    0S2

    SB 7

    320S

    2

    SB 7

    315S

    2

    SB 7

    324S

    2

    A 3-pole Contactors - A.C. OperatedA.C. Circuit SwitchingOrdering Details

    A 9-30-10

    A 16-30-10

    A 30-30-10

    A 50-30-00

    A 95-30-00

  • 2/131SBC 0004 99 R1001

    Low Voltage Products

    2

    Type Order code Mounted Rated operational Motor power AC-3 WeightState coil to be completed with coil aux. cont. current 220 V 380 V in kgvoltage: n n voltage: nn n n AC-1 AC-3 230 V 400 V 415 V 690 V

    40C 400 V 240 V PackingSee page 0/1 See page 0/1 A A kW kW kW kW 1 piece

    EH 145-30-11 nn SK 824 021- nn n n 1 1 230 145 45 75 75 110 2.30EH 145-30-22 nn SK 824 031- nn n n 2 2 230 145 45 75 75 110 2.35

    EH 175-30-11 nn SK 825 401- nn n n 1 1 260 185 55 90 90 132 4.65EH 175-30-21 nn SK 825 401- E nn 2 1 260 185 55 90 90 132 4.65EH 175-30-22 nn SK 825 411- nn n n 2 2 260 185 55 90 90 132 4.70

    EH 210-30-11 nn SK 825 402- nn n n 1 1 300 210 59 110 110 160 4.65EH 210-30-21 nn SK 825 402- E nn 2 1 300 210 59 110 110 160 4.65EH 210-30-22 nn SK 825 412- nn n n 2 2 300 210 59 110 110 160 4.70

    EH 260-30-11 nn SK 826 402- nn n n 1 1 400 260 80 140 140 200 6.20EH 260-30-21 nn SK 826 402- E nn 2 1 400 260 80 140 140 200 6.20EH 260-30-22 nn SK 826 412- nn n n 2 2 400 260 80 140 140 200 6.25

    EH 300-30-11 nn SK 826 401- nn n n 1 1 445 305 90 160 160 250 6.20EH 300-30-21 nn SK 826 401- E nn 2 1 445 305 90 160 160 250 6.20EH 300-30-22 nn SK 826 411- nn n n 2 2 445 305 90 160 160 250 6.25

    EH 370-30-11 nn SK 827 004- nn n n 1 1 550 400 110 200 220 355 12.40EH 370-30-22 nn SK 827 030- nn n n 2 2 550 400 110 200 220 355 12.45

    EH 550-30-11 nn SK 827 005- nn n n 1 1 800 550 160 280 315 500 12.40EH 550-30-22 nn SK 827 031- nn n n 2 2 800 550 160 280 315 500 12.45

    EH 700-30-11 nn SK 828 004- nn n n 1 1 1000 700 220 370 400 600 17.10EH 700-30-22 nn SK 828 030- nn n n 2 2 1000 700 220 370 400 600 17.15

    EH 800-30-11 nn SK 828 005- nn n n 1 1 1000 750 220 400 425 650 17.30EH 800-30-22 nn SK 828 031- nn n n 2 2 1000 750 220 400 425 650 17.35

    - E n n = 40 - 400 Hz coil with built-in rectifier.

    l Technical Data ............................................ pages 2/33, 2/39 l General - Approvals .............................................. Section 7l Accessories ............................................................. Section 4 l Terminal Marking and Positioning ...................... Section 8l Thermal O/L Relays ................................................ Section 5 l Dimensions ............................................................ Section 9

    EH 700-30-11

    EH 3-pole Contactors - A.C. OperatedA.C. Circuit SwitchingOrdering Details

    EH 145-30-11

    EH 370-30-11

    EH 260-30-11

    EH 175-30-11

    SB 7

    338S

    2

    SB 7

    345S

    2SB

    734

    8S2

    SB 7

    347S

    3

    SB 7

    351S

    3

  • Low Voltage Products1SBC 0004 99 R10012/14

    }

    l Technical Data ...................................................... page 2/38 l General - Approvals .............................................. Section 7l Accessories ........................................................... Section 4 l Terminal Marking and Positioning ...................... Section 8l Thermal O/L Relays .............................................. Section 5 l Dimensions ............................................................ Section 9

    BC 3-pole Contactors - D.C. OperatedA.C. Circuit SwitchingOrdering Details

    Type Order code Mounted aux. contacts Rated operational Motor power AC-3 WeightState coil to be completed with coil 1st stack 2nd stack current 220 V 380 V in kgvoltage: nn voltage: nn . . nn AC -1 AC-3 230 V 400 V 415 V 690 V

    40C 400 V 240 V PackingSee page 0/1 See page 0/1 A A kW kW kW kW 1 piece

    BC 9-30-10 nn FPL 141 3001 R nn 10 nn 1 22 9 2.2 4 4 4 0.54BC 9-30-01 nn FPL 141 3001 R nn 01 nn 1 22 9 2.2 4 4 4 0.54

    BC 16-30-10 nn FPL 181 3001 R nn 10 nn 1 28 16 4 7.5 7.5 5.5 0.54BC 16-30-01 nn FPL 181 3001 R nn 01 nn 1 28 16 4 7.5 7.5 5.5 0.54

    BC 18-30-22 nn GJL 222 3001 R nn 22 nn 2 2 36 16 4 7.5 7.5 7.5 0.57

    BC 25-30-10 nn GJL 241 3001 R nn 10 nn 1 45 25 6.5 * 11 11 11 0.62BC 25-30-01 nn GJL 241 3001 R nn 01 nn 1 45 25 6.5 * 11 11 11 0.62

    BC 30-30-00 nn GJL 281 3001 R nn 00 nn 55 30 9 15 15 15 0.70BC 30-30-22 nn GJL 282 3001 R nn 22 nn 2 2 55 30 9 15 15 15 0.76

    * 7.5 kW at 240 V.

    Mounting Distance required between BC contactors.d(1) D(2) Ambient temperature Max. switching frequencymm mm C Operating cycles/h2 20 20 12005 20 55 1200

    Mounting Positions of BC contactors.The following table gives the permissible mounting positions depending on the ambient temperature, contactorcoil operating limits and whether or not there are add-on accessories: auxiliary contact blocks, pneumatic timer.

    Ambient Contactor Permissible Coil Add-on accessoriestemp. without accessory mounting operating 1-pole aux. contacts or 4-pole aux. contacts or Timer

    Poles Built-in positions limits CA5-10 CA5-01 CA5-40 (4 x N.O.) TP 40 DA/IAaux. cont. (N.O.) (N.C.) or CA5-31 (3 x N.O. + 1 x N.C.) orTP 180 DA/IA

    or CA5-22 (2 x N.O. + 2 x N.C.)or CA5-04 (4 x N.C.)

    C Pos. x Uc Qty: Qty: Qty: Qty:1, 3, 4 0.85 -1.1 1 to 4 1 1

    55 130, 2, 6 0.95 -1.1 1 to 4 1 15* 0.85 -1.1 1 to 4 inc. 2xN.C. max. 1** TP..DA

    > 55 1, 1 30, and 2, 3, 4 Uc 1 to 4 1 1 70 5* Uc 1 to 4 inc. 2xN.C. max. 1** TP..DA

    * In position 5, do not use the RD7 diode unit: consult us. Maximum operating voltage: Ue < 440 V a.c.** In position 5, do not use the CA5-04 auxiliary contact block.

    Note: For selection and use of surge suppressors (e.g. diode, varistor, etc.), see notes page 4/14.

    BC 9-30-10

    SB 6

    994S

    4

    BC 25-30-10

    BC 30-30-00

    SB 6

    490S

    4SB

    699

    7S4

    BC 9 - BC 25 - 30 - 10BC 30 - 30 - 00BC 9 - 30 - 01BC 16 - 30 - 01BC 25 - 30 - 01

    BC 9 - BC 25 - 30 - 10BC 30 - 30 - 00BC 9 - 30 - 01BC 16 - 30 - 01BC 25 - 30 - 01

    }

  • 2/151SBC 0004 99 R1001

    Low Voltage Products

    2

    Type Order code Mounted Rated operational Motor power AC-3 WeightState coil to be completed with coil aux. cont. current 220 V 380 V in kgvoltage: nn voltage: nn n n AC-1 AC-3 230 V 400 V 415 V 690 V

    40C 400 V 240 V PackingSee page 0/1 See page 0/1 A A kW kW kW kW 1 piece

    AE 50-30-00 nn 1SBL 35 9001 R nn n n 00 100 50 15 22 25 30 1.20AE 50-30-11 nn 1SBL 35 9001 R nn n n 11 1 1 100 50 15 22 25 30 1.24

    AE 63-30-00 nn 1SBL 37 9001 R nn n n 00 115 65 18.5 30 37 37 1.20AE 63-30-11 nn 1SBL 37 9001 R nn n n 11 1 1 115 65 18.5 30 37 37 1.24

    AE 75-30-00 nn 1SBL 41 9001 R nn n n 00 125 75 22 37 40 40 1.20AE 75-30-11 nn 1SBL 41 9001 R nn n n 11 1 1 125 75 22 37 40 40 1.24

    AE 95-30-00 nn 1SFL 43 9001 R nn n n 00 145 96 25 45 55 55 2.04AE 95-30-11 nn 1SFL 43 9001 R nn n n 11 1 1 145 96 25 45 55 55 2.07

    AE 110-30-00 nn 1SFL 45 9001 R nn n n 00 160 110 30 55 59 75 2.04AE 110-30-11 nn 1SFL 45 9001 R nn n n 11 1 1 160 110 30 55 59 75 2.07

    EH 145-30-21 nn SK 824 021- nn n n 2 1 230 145 45 75 75 110 2.30

    EH 175-30-21 nn SK 825 401- nn n n 2 1 260 185 55 90 90 132 4.70

    EH 210-30-21 nn SK 825 402- nn n n 2 1 300 210 59 110 110 160 4.70

    EH 260-30-21 nn SK 826 402- nn n n 2 1 400 260 80 140 140 200 6.20

    EH 300-30-21 nn SK 826 401- nn n n 2 1 445 305 90 160 160 250 6.25

    EH 370-30-21 nn SK 827 004- nn n n 2 1 550 400 110 200 220 355 12.40

    EH 550-30-21 nn SK 827 005- nn n n 2 1 800 550 160 280 315 500 12.40

    EH 700-30-21 nn SK 828 004- nn n n 2 1 1000 700 220 370 400 600 17.10

    EH 800-30-21 nn SK 828 005- nn n n 2 1 1000 750 220 400 425 650 17.30

    Block diagram for AE Contactor Coil Supply.

    l Technical Data ...................................................... page 2/38 l General - Approvals .............................................. Section 7l Accessories .......................................................... Section 4 l Terminal Marking and Positioning ...................... Section 8l Thermal O/L Relays .............................................. Section 5 l Dimensions ............................................................ Section 9

    AE and EH 3-pole Contactors - D.C. OperatedA.C. Circuit SwitchingOrdering Details

    N.C. lagging auxiliary contact block with built-in varistor: CDL 5-01 type on AE 50-AE 75 contactors. CCL 5-01 type on AE 95 and AE110 contactors.

    AE 50-30-00

    SB 7

    582S

    4

    EH 210-30-11

    SB 7

    592S

    4

  • Low Voltage Products1SBC 0004 99 R10012/16

    l Technical Data ....................................................... page 2/32 l Terminal Marking and Positioning ...................... Section 8l Accessories ............................................................. Section 4 l Dimensions ............................................................ Section 9l General - Approvals ................................................ Section 7

    A and EK 4-pole Contactors - A.C. OperatedA.C. Circuit Switching

    SB 7

    319S

    3

    SB 7

    343S

    3

    Ordering DetailsType Order code Mounted aux. Rated operational WeightState coil to be completed with coil contacts current in kgvoltage: nn voltage code: nn n n AC -1 AC-1

    40C 55C PackingSee page 0/1 See page 0/1 A A 1 piece

    A 9-40-00 nn 1SBL 14 1201 R nn n n 00 25 22 0.34A 16-40-00 nn 1SBL 18 1201 R nn n n 00 30 27 0.34A 26-40-00 nn 1SBL 24 1201 R nn n n 00 45 40 0.61A 45-40-00 n n (1) 1SBL 33 1201 R nn n n 00 70 60 1.39A 50-40-00 n n (1) 1SBL 35 1201 R nn n n 00 100 85 1.39A 75-40-00 n n (1) 1SBL 41 1201 R nn n n 00 125 105 1.39EK 110-40-11 nn SK 824 440- nn nn 1 1 200 180 4.30EK 110-40-21 nn SK 824 440- E nn 2 1 200 180 4.30EK 110-40-22 nn SK 824 450- nn nn 2 2 200 180 4.35EK 150-40-11 nn SK 824 441- nn nn 1 1 250 230 4.35EK 150-40-21 nn SK 824 441- E nn 2 1 250 230 4.35EK 150-40-22 nn SK 824 451- nn nn 2 2 250 230 4.40EK 175-40-11 nn SK 825 440- nn nn 1 1 300 270 6.60EK 175-40-21 nn SK 825 440- E nn 2 1 300 270 6.60EK 175-40-22 nn SK 825 448- nn nn 2 2 300 270 6.65EK 210-40-11 nn SK 825 441- nn nn 1 1 350 310 6.60EK 210-40-21 nn SK 825 441- E nn 2 1 350 310 6.60EK 210-40-22 nn SK 825 451- nn nn 2 2 350 310 6.65EK 370-40-11 nn SK 827 040- nn nn 1 1 550 470 17.2EK 370-40-22 nn SK 827 042- nn nn 2 2 550 470 17.2EK 550-40-11 nn SK 827 041- nn nn 1 1 800 650 17.2EK 550-40-22 nn SK 827 043- nn nn 2 2 800 650 17.2

    - E n n = 40 - 400 Hz coil with built-in rectifier.(1) 60 Hz coil voltage

    Mounting positions 1 to 5 (see page 2/37) and ambient temperature 55C: tolerance reduced to 0.9 - 1.1 Uc (instead of 0.85 - 1.1 Uc) for coilvoltage codes 7 nn and 8 nn . This only concerns devices fitted with CA 5 - and CAL5-11 auxiliary contacts or TP timer.For mounting position 6 or ambient temperature of +55 to +70 C the information given on page 2/34 remains applicable.

    A 45-40-00

    EK 370-40-11

    SB 7

    314S

    2

    A 9-40-00

    EK 175-40-11

    SB 7

    341S

    3

  • 2/171SBC 0004 99 R1001

    Low Voltage Products

    2

    Ordering DetailsType Order code Mounted aux. Rated operational WeightState coil to be completed with coil contacts current in kgvoltage: nn voltage: nn n n AC -1 AC-1

    40C 55C PackingSee page 0/1 See page 0/1 A A 1 piece

    BC 9-40-00 n n (1) FPL 141 3201 R nn 00 nn 22 20 0.54BC 16-40-00 n n (1) FPL 181 3201 R n n 00 nn 28 25 0.54BC 25-40-00 n n (1) GJL 241 3201 R n n 00 nn 45 40 0.62AE 45-40-00 nn 1SBL 33 9201 R nn n n 00 70 60 1.43AE 50-40-00 nn 1SBL 35 9201 R nn n n 00 100 85 1.43AE 75-40-00 nn 1SBL 41 9201 R nn n n 00 125 105 1.43EK 110-40-21 nn SK 824 440- nn nn 2 1 200 180 4.35EK 150-40-21 nn SK 824 441- nn nn 2 1 250 230 4.40EK 175-40-21 nn SK 825 440- nn nn 2 1 300 270 6.65EK 210-40-21 nn SK 825 441- nn nn 2 1 350 310 6.65EK 370-40-21 nn SK 827 040- nn nn 2 1 550 470 17.2EK 550-40-21 nn SK 827 041- nn nn 2 1 800 650 17.2

    (1) l Distances and mounting positions: see page 2/14.l For selection and use of surge suppressors (e.g. diode, varistor, etc.) see notes page 4/14.

    Block Diagram for AE Contactor Coil Supply.

    l Technical Data ..................................................... page 2/38 l General - Approvals .............................................. Section 7l Accessories ........................................................... Section 4 l Terminal Marking and Positioning ...................... Section 8l Thermal O/L Relay ................................................ Section 5 l Dimensions ............................................................ Section 9

    BC, AE and EK 4-pole Contactors - D.C. OperatedA.C. Circuit Switching

    SB 6

    992S

    2

    BC 16-40-00

    EK 110-40-21

    AE 50-40-00

    SB 7

    594S

    4SB

    759

    0S4

    Mounting Distance required between BC contactors.d(1) D(2) Ambient temperature Max. switching frequencymm mm C Operating cycles/h2 20 20 12005 20 55 1200

    Mounting Positions of BC contactors.The following table shows permissible mounting positions depending on the ambient temperature, contactorcoil operating limits and whether or not there are add-on accessories: auxiliary contact blocks, pneumatic timer.

    Ambient Contactor Permissible Coil Add-on accessoriestemp. without accessory mounting operating 1-pole aux. contacts or 4-pole aux. contacts or Timer

    Poles Built-in . positions limits CA5-10 CA5-01 CA5-40 (4 x N.O.) TP 40 DA/IAaux. cont. (N.O.) (N.C.) or CA5-31 (3 x N.O. + 1 x N.C.) orTP 180 DA/IA

    or CA5-22 (2 x N.O. + 2 x N.C.)or CA5-04 (4 x N.C.)

    C Pos. x Uc Qty: Qty: Qty: Qty:

    1, 3, 4 0.85 -1.1 1 to 4 1 1

    55 BC 9 - BC 25 - 40 - 00 130, 2, 6 0.95 -1.1 1 to 4 1 15* 0.85 -1.1 1 to 4 inc. 2xN.C. max. 1** TP..DA

    > 55BC 9 - BC 25 - 40 - 00

    1,130,2,3,4 Uc 1 to 4 1 1and

    < 70 5* Uc 1 to 4 inc. 2xN.C. max. 1** TP..DA* In position 5, do not use the RD7 diode unit, please consult us. Maximum operating voltage: Ue < 440 V a.c.** In position 5, do not use the CA5-04 auxiliary contact block.

    Note: For selection and use of surge suppressors (e.g. diode, varistor, etc.), see notes page 4/14.

    }

    }

  • Low Voltage Products1SBC 0004 99 R10012/18

    A 4-pole Contactors with N.O. and N.C. Main PolesA.C. Circuit SwitchingA.C. Operated

    Descriptionl 4-pole contactors fitted with 2 N.C. main poles and 2 N.O. main poles.l These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or

    1 circuit comprising 2 separate loads with a single supply (see diagram below). When the contactor operatesthere is no mechanical overlapping between the N.O. poles and the N.C. poles: BREAK before MAKE.

    These contactors are not suitable for a reversing starter or star-delta starter or for controlling a singleload from 2 separate supplies.

    Block Diagramsl Single supply and 2 separate loads l 2 separate supplies and 2 separate loads

    Ordering DetailsType Order code Mounted Rated operational WeightState coil to be completed with coil aux. contacts current at Ue 690 V in kgvoltage: n n voltage: n n nn AC -1 AC-1

    40C 55C PackingSee page 0/1 See page 0/1 A A 1 piece

    A 9-22-00 n n (1) 1SBL 14 1501 R nn n n 00 25 22 0.34A 16-22-00 n n (1) 1SBL 18 1501 R nn n n 00 30 27 0.34A 26-22-00 nn 1SBL 24 1501 R nn n n 00 45 40 0.61A 45-22-00 n n (1) (2) 1SBL 33 1501 R nn n n 00 70 60 1.40A 75-22-00 n n (1) (2) 1SBL 41 1501 R nn n n 00 125 105 1.40

    (1) For A 9 and A 16-22 in position 5 or A 45 and A 75-22 in positions 1, 2, 3, 4, or 6 (position 5 unauthorised), do not use more than 2 add-on front-mounted N.C. auxiliary contact blocks. CAL 5-11 side-mounted blocks provide extra N.C. auxiliary contacts

    (2) A 45 and A 75-22 contactors: Shock withstand: in position 1, contactors being screwed on their support and without extra N.C. auxiliary contact.

    1/2 sinusoidal shock, 11 ms: no change in contact position.Shock directions : A, C1, C2 : 20g

    B1 : 3gB2 : 10g.

    60 Hz Coil Voltage: for mounting positions 1 to 4 and ambient temperature < 55 C: tolerance reduced to 0.9 - 1.1 Uc(instead of 0.85 - 1.1 Uc) for 7 nn and 8 n n coil voltage codes.This only concerns devices fitted with CA 5 - and CAL 5-11 auxiliary contacts or TP timer.Position 5 unauthorised.For mounting position 6 or ambient temperature of +55 to +70 C, the information given on page 2/34 remains applicable.

    l Technical Data ....................................................... page 2/32 l Terminal Marking and Positioning ...................... Section 8l Accessories ............................................................. Section 4 l Dimensions ............................................................ Section 9l General - Approvals ................................................ Section 7

    A 26-22

    SB 7

    588S

    4

    A 45-22

    SB 7

    819S

    4

    Mounting positions:

  • 2/191SBC 0004 99 R1001

    Low Voltage Products

    2

    Description (as for page 2/18)

    Ordering DetailsType Order code Mounted Rated operational WeightState coil to be completed with coil aux. contacts current at Ue 690 V in kgvoltage: nn voltage: nn nn AC -1 AC-1

    40C 55C PackingSee page 0/1 See page 0/1 A A 1 piece

    BC 9-22-00 nn FPL 141 3501 R nn 00 nn 22 20 0.540BC 16-22-00 nn FPL 181 3501 R nn 00 nn 28 25 0.540BC 25-22-00 nn GJL 241 3501 R nn 00 nn 45 40 0.620AE 45-22-00 nn 1SBL 33 9501 R nn n n 00 70 60 1.44AE 75-22-00 nn 1SBL 41 9501 R nn n n 00 125 105 1.44

    }}

    }}}

    BC and AE 4-pole Contactorswith N.O. and N.C. Main PolesA.C. Circuit Switching - D.C. Operated

    l Technical Data ....................................................... page 2/38 l Terminal Marking and Positioning ...................... Section 8l Accessories ............................................................. Section 4 l Dimensions ............................................................ Section 9l General - Approvals ................................................ Section 7

    Mounting Distance required between BC contactors.d(1) D(2) Ambient temperature Max. switching frequencymm mm C Operating cycles/h2 20 20 6005 20 55 600

    Mounting Positions of BC 9 - BC 25-22, AE 45 and AE 75-22 4-pole contactors.The following table shows permissible mounting positions in relation to the ambient temperature, contactor coiloperating limits and whether or not there are add-on accessories: auxiliary contact blocks, pneumatic timer.

    Ambient Contactor Permissible Coil Add-on accessoriestemp. without accessory mounting operating 1-pole aux. contacts or 4-pole aux. contacts or Timer

    Poles Built-in positions limits CA5-10 CA5-01 CA5-40 (4 x N.O.) TP 40 DA/IAaux. cont. (N.O.) (N.C.) or CA5-31 (3 x N.O. + 1 x N.C.) orTP 180 DA/IA

    or CA5-22 (2 x N.O. + 2 x N.C.) C Pos. x Uc Qty: Qty: Qty: Qty:

    BC 9 - 22 - 001, 2, 3, 4 0.85 -1.1 1 to 4 inc. 2xN.C max. 1 -

    55BC 16 - 22 - 00

    1 30 0.85 -1.1 1 to 4 - 1 CA5-40 -6 0.95 -1.1 1 to 4 inc. 2xN.C. max. 1 -

    > 55 BC 9 - 22 - 00 1, 2, 3, 4 Uc 1 to 4 inc. 2xN.C. max. 1 -and

    < 70 BC 16 - 22 - 00 1 30 Uc 1 to 4 - 1 CA5-40 -

    < 55 BC 25 - 22 - 001, 2 0.85 -1.1

    1 to 4 - 1 CA5-40 -130,3,4,6 0.95 -1.1

    > 55 1, 1 30and

    < 70BC 25 - 22 - 00 2, 3, 4 Uc 1 to 4 - 1 CA5-40 -

    AE 45 - 22 - 00 1, 1 30 0.85 - 1.11 1

    < 55 2, 3, 4 1 to 6 inc. 2xN.C.max. +1 to 2 CA5 1-pole +1 to 2 CA5AE 75 - 22 - 00

    6 0.95 - 1.1 Do not exceed 2xN.C. 1-pole

    > 55 AE 45 - 22 - 00 1, 1 30and

    < 70 AE 75 - 22 - 00 2, 3, 4Uc 1 to 6 inc. 2xN.C.max.

    Note: For selection and use of surge suppressors (e.g. diode, varistor, etc.) with BC - contactorssee notes page 4/14.

    SB 6

    993S

    3

    BC 9-22-00

    AE 45-22-00

    SB 7

    591S

    4

    1 1+1 to 2 CA5 1-pole +1 to 2 CA5

    Do not exceed 2xN.C. 1-pole

    }

  • Low Voltage Products1SBC 0004 99 R10012/20

    3-pole Contactorsfor 3-phase Capacitor SwitchingA.C. Operated

    GeneralThe most common application is the parallel connection of 3-phase capacitors to a load or part of a circuit for power factor correction.When connecting three-phase capacitors for compensation purposes, a distinction must be made between:

    Compensation via a single capacitor bank. Compensation via a stepped capacitor bank.

    On energization, the capacitor is connected in parallel with the inductive network. A 3 to 15 kHz high frequency current, which may reach 160 In for1 to 2 ms in the case of stepped bank compensation, flows through the oscillating circuit set up by the connection of the capacitor with the network.The presence of harmonics and the supply voltage tolerance lead to a current, estimated to be 1.3 times the nominal current In of the capacitor,continuously circulating in the circuit.Taking into account the manufacturing tolerances, the exact power of a capacitor can reach 1.15 times its nominal power.The contactor must therefore be sized to withstand:

    the short but high peak current during closing. See the peak current values in the following tables. Additional reactors may be used to limitthe peak inrush current.

    a permanent current IT able to reach 1.5 times the nominal current of the capacitor. This factor has been taken into account in the selectiontables below.

    Short-circuit protection is generally ensured by gG fuses, sized 1.5 - 1.8 In of the capacitor.Consult us for different conditions of use (higher inrush current, greater rate of harmonics).

    Selection TableSelect the type of contactor in relation to the following characteristics:- operational voltage - power in kvar - maximum contactor peak - ambient temperature close to contactor.

    The capacitors must be fully discharged (maximum voltage at terminals 50 V) before being re-energized when the contactors are making.

    A and EH Types Standard 3-pole ContactorsFor 3-phase capacitors carrying out single capacitor bank or stepped bank compensation. peak max. < 30 times the capacitor nominal r.m.s. current.Electrical durability: 100 000 operating cycles - Ordering details: see pages 2/12 and 2/13.

    Power in kvar 50/60 Hz Max. peakType 220/240 V 380/400 V 415/440 V 500/550V 660/690 V current

    40 C 55 C 70 C 40 C 55 C 70 C 40 C 55 C 70 C 40 C 55 C 70 C 40 C 55 C 70 C (kA)A 9 - - - - - - - - - - - - - - - -A 12 7 7 6 11 11 9.5 12 12 10.5 14 14 12 19 19 16.5 0.7A 16 7.5 7.5 6 12.5 12.5 10 14 14 10.5 15.5 15.5 12 21.5 21.5 16.5 1A 26 11.5 11.5 9 19 19 15 20 20 16.5 23 23 19 32 32 26 1.6A 30 13 13 11 22 22 18.5 24 24 20.5 28 28 23 38 38 32 1.9A 40 15 15 12 26 26 20 29 29 22 35 35 25 46 46 34.5 2.1A 50 22 22 20 38 38 34 42 42 37 48 48 42 65 65 58.5 2.3A 63 25 25 23 43 43 39 47 47 42.5 54 54 48.5 74 74 67 2.5A 75 28 28 24.5 48 48 41 52 52 45 60 60 51 82 82 70 2.6A 95 35 35 33 60 60 53 63 63 58 75 75 70 80 80 75 4

    A 110 40 40 35 70 70 60 75 75 65 83 83 78 90 90 85 4EH 145 50 50 42 90 90 74 93 93 80 110 110 96 110 110 110 4EH 175 60 60 45 105 105 78 115 115 85 135 135 102 135 135 135 5EH 210 75 75 57 125 125 99 135 135 108 160 160 130 160 160 160 5EH 260 85 85 70 140 140 130 155 155 140 180 180 165 200 200 200 8EH 300 100 100 85 160 160 150 180 180 163 210 210 196 240 240 240 8EH 370 120 120 105 200 200 185 220 220 200 260 260 241 300 300 300 10EH 550 160 160 150 260 260 255 290 290 289 340 340 340 440 440 440 10EH 700 210 210 190 350 350 332 380 380 360 460 460 435 550 550 550 12EH 800 220 212 191 390 370 332 410 402 360 490 480 435 600 600 600 12

  • 2/211SBC 0004 99 R1001

    Low Voltage Products

    2

    UA 3-pole Contactorsfor 3-phase Capacitor SwitchingA.C. Operated

    l Accessories ........................................................... Section 4 l Terminal Marking and Positioning ...................... Section 8l General - Approvals .............................................. Section 7 l Dimensions ............................................................ Section 9

    Ordering DetailsType Order code Mounted WeightState coil to be completed with coil aux. cont. in kgvoltage: nn voltage: nn nn

    PackingSee page 0/1 See page 0/1 1 piece

    UA 3-pole contactorsUA 26-30-10 nn 1SBL 24 1022 R nn n n 10 1 0.60UA 30-30-10 nn 1SBL 28 1022 R nn n n 10 1 0.71UA 50-30-00 nn 1SBL 35 1022 R nn n n 00 1.16UA 50-30-11 nn 1SBL 35 1022 R nn n n 11 1 1 1.20UA 63-30-00 nn 1SBL 37 1022 R nn n n 00 1.16UA 63-30-11 nn 1SBL 37 1022 R nn n n 11 1 1 1.20UA 75-30-00 nn 1SBL 41 1022 R nn n n 00 1.16UA 75-30-11 nn 1SBL 41 1022 R nn n n 11 1 1 1.20UA 95-30-00 nn 1SFL 43 1022 R nn n n 00 2.00UA 95-30-11 nn 1SFL 43 1022 R nn n n 11 1 1 2.04UA 110-30-00 nn 1SFL 45 1022 R nn n n 00 2.00UA 110-30-11 nn 1SFL 45 1022 R nn n n 11 1 1 2.04

    AccessoriesUA contactor accessories are the same as those of standard A contactors (see section 4).

    UA Type 3-pole ContactorsFor 3-phase capacitors carrying out single bank or stepped bank compensation.Max. peak current : 100 times the capacitor nominal r.m.s. current at Ue < 500 V or 90 times for Ue > 500 VElectrical durability: 100 000 operating cycles - Ordering details: see below.

    Power in kvar 50/60 Hz Max. permissibleType 230/240 V 400/415 V 440 V 500/550 V 660/690 V peak current (kA)

    40 C 55 C 70 C 40 C 55 C 70 C 40 C 55 C 70 C 40 C 55 C 70 C 40C 55C 70 C Ue < 500 V Ue > 500 VUA 26 12 11 8.5 20 18.5 14.5 22 20 16 22 22 19.5 30 30 25 3 2.7UA 30 16 16 11 27.5 27.5 19 30 30 20 34 34 23.5 45 45 32 3.5 3.1UA 50 20 20 19 33 33 32 36 36 35 40 40 40 55 55 52 5 4.5UA 63 25 25 21 45 43 37 50 48 41 50 50 45 70 70 60 5.5 5UA 75 30 30 22 50 50 39 55 53 43 62 62 47.5 75 75 65 6 5.8UA 95 35 35 29 60/65* 60/65* 50/55* 65 65 55 70 70 60 86 86 70 9.3 8UA 110 40 39 34 74 70/75* 65 75 75 67 80 80 75 90 90 85 10.5 9* Use these values for Ue = 415 VFor kvar rated power at 220 V and 380 V, apply factor 0.9 on kvar rated power at 230 V and 400 V respectively.Example with 50 kvar/400 V : 50 x 0.9 = 45 kvar/380 V.

    UA 50-30-00

    SB 7

    597S

    4

    SB 7

    598S

    4

    UA 95-30-00

  • Low Voltage Products1SBC 0004 99 R10012/22

    UA .. -R 3-pole Contactorsfor 3-phase Capacitor SwitchingA.C. Operated

    UA .. -R type 3-pole ContactorsFor 3-phase capacitors carrying out single bank or stepped bank compensation.Rated operational power: according to Ue rated operational voltage and air temperature close to contactor (see table below).

    Insertion of resistors releases the contactor from overloading making currents.

    DescriptionUA .. -R contactors are equipped with resistors and the relevant insertion contacts.The insertion contacts make and break prior to the main poles (shifted operation about a few milliseconds).Making sequence

    first step: the early-make insertion contacts switch-on the current to the capacitor via the damping resistors. second step: main poles are making.The insertion contacts stay closed, ready to operate as early-breaking contacts for the next breaking sequence.

    Breaking sequence first step: the insertion contacts operate as early-breaking ones and switch-off the resistances circuitry. second step: main poles are breaking the capacitor load.

    Block Diagram

    The capacitors must be discharged (maximum residual voltage at terminals

  • 2/231SBC 0004 99 R1001

    Low Voltage Products

    2

    SB78

    23S2

    UA 26-30-10-R

    SB78

    20S2

    UA 30-30-10-R

    SB78

    21S2

    UA 75-30-00-R

    UA .. -R 3-pole Contactorsfor 3-phase Capacitor SwitchingA.C. Operated

    Technical DataDurability 250 000 operating cycles at Ue 500 VOperating frequency 240 cycles/h

    Degree of protection UA 16..-R, UA 26..-R UA 30..-R UA 75..-Racc. to IEC 529,IEC 947-1and EN 60529, EN 60947-1 Main terminals IP 20 IP 10 Coil terminals IP 20 IP 20 Auxiliary terminals IP 20 IP 20

    Connecting capacity UA 16..-R UA 26..-R UA30..-R UA 50..-RUA 75..-RMain conductors (poles) rigid solid (6 mm2) min. - max. min. - max. min. - max. min. - max.

    1 x mm2 1 4 1.5 6 2.5 16 6 502 x mm2 2.516 + 2.56 625 + 616

    flexible without cable end min. - max. min. - max. min. - max. min. - max.1 x mm2 0.75 2.5 1 4 2.5 10 6 352 x mm2 2.510 + 2.54 616 + 610

    Short-circuit protection gG fuses sized 1.5 1.8 In of the capacitor.

    Other characteristics are the same as those of standard A contactors.

    AccessoriesUA .. - R contactor accessories are the same as those of standard A contactors (see section 4).

    l Accessories, coils, contacts ................................. Section 4 l Terminal Marking and Positionning ...................... Section 8l Generals, Approvals ............................................... Section 7 l Dimensions ............................................................. Section 9

    SB78

    22S2

    UA 16-30-10-R

  • Low Voltage Products1SBC 0004 99 R10012/24

    TBC and TAE Contactorswith Large Coil Voltage RangeD.C. Operated - A.C. Circuit Switching

    ApplicationTBC and TAE contactors with a large coil voltage range are designed to operate in control circuits with largevoltage variations. Example: battery supply.

    Ordering Details, 3-pole ContactorsType Order code Mounted Rated operational Motor power AC-3 WeightState coil to be completed with coil aux. cont. current 220 V 380 V in kgvoltage: n n voltage: nn . . nn AC -1 AC-3 230 V 400 V 415 V 690 V

    40C 400 V 240 V PackingSee table opposite See table opposite A A kW kW kW kW 1 piece

    TBC 9-30-10 nn FPL 141 3061 R nn 10 nn 1 22 9 2.2 4 4 4 0.54TBC 9-30-01 nn FPL 141 3061 R nn 01 nn 1 22 9 2.2 4 4 4 0.54TBC 16-30-10 nn FPL 181 3061 R nn 10 nn 1 28 16 4 7.5 7.5 5.5 0.54TBC 16-30- 01 nn FPL 181 3061 R nn 01 nn 1 28 16 4 7.5 7.5 5.5 0.54TBC 25-30-10 nn GJL 241 3061 R nn 10 nn 1 45 25 6.5 11 11 11 0.62TBC 25-30-01 nn GJL 241 3061 R nn 01 nn 1 45 25 6.5 11 11 11 0.62TBC 30-30-00 nn GJL 281 3061 R nn 00 nn 55 30 9 15 15 15 0.70TBC 30-30-22 nn GJL 282 3061 R nn 22 nn 2 2 55 30 9 15 15 15 0.76TAE 50 -30 -00 nn 1SBL 35 9061 R nn n n 00 100 50 15 22 25 30 1.20TAE 50 -30 -11 nn 1SBL 35 9061 R nn nn 11 1 1 100 50 15 22 25 30 1.24TAE 75-30 -00 nn 1SBL 41 9061 R nn n n 00 125 75 22 37 40 40 1.20TAE 75-30 -11 nn 1SBL 41 9061 R nn nn 11 1 1 125 75 22 37 40 40 1.24TAE 95-30 -00 nn 1SFL 43 9061 R nn nn 00 145 96 25 45 55 55 2.04TAE 95-30 -11 nn 1SFL 43 9061 R nn nn 11 1 1 145 96 25 45 55 55 2.07TAE 110-30 -00 nn 1SFL 45 9061 R nn nn 00 160 110 30 55 59 75 2.04TAE 110-30 -11 nn 1SFL 45 9061 R nn nn 11 1 1 160 110 30 55 59 75 2.07

    Coil operating limits:Voltage V -d.c. Code

    R nn . . n nor

    min. Uc max. R nn n n . .17 ........... 32 nn n n25 ........... 45 nn n n36 ........... 65 nn n n42 ........... 78 nn n n50 ........... 90 nn n n77 ......... 143 nn n n90 ......... 150 nn n n

    152 ........ 264 nn n nOther voltages: please consult us.

    TBC 9-30-01

    SB 6

    996S

    3

    5 4

    5 2

    5 1

    5 5

    6 6

    6 8

    6 2

    5 8

    l General - Approvals .............................................. Section 7 l Cited Acceptable Accessories ............................... Section 4l Terminal Marking and Positioning ...................... Section 8 l Railway/Traction Projects ...................................... on request

    TBC 16-22-00

    TBC 25-40-00

    FRCT

    L 69

    95S5

    FRCT

    L 69

    91S5

    Ordering Details, 4-pole ContactorsType Order code Mounted Rated operational WeightState coil to be completed with coil aux. contacts current in kgvoltage: nn voltage: n n . . nn AC -1 AC-1

    40C 55C PackingSee table opposite See table opposite A A 1 piece

    4-pole contactor fitted with 4 N.O. main poles

    TBC 9- 40-00 nn FPL 141 3261 R nn 00 nn 22 20 0.54TBC 16- 40-00 nn FPL 181 3261 R nn 00 nn 28 25 0.54TBC 25- 40-00 nn GJL 241 3261 R nn 00 nn 45 40 0.62TAE 45-40-00 1SBL 33 9261 R n nn n 00 70 60 1.43TAE 50-40-00 1SBL 35 9261 R n nn n 00 100 85 1.43TAE 75-40-00 1SBL 41 9261 R n nn n 00 125 105 1.43

    4-pole contactor fitted with 2 N.O. main poles and 2 N.C. main polesThese contactors can be used for controlling either 2 separate circuits, i.e. 2 loads with 2 separate supplies,or 1 circuit comprising 2 separate loads with 1 single supply (see diagram page 2/18).When the contactor operates, there is no mechanical overlapping between the N.O. main poles andN.C. main poles: BREAK before MAKE.

    These contactors are not suitable for a reversing starter or a star-delta starter or for controlling a singleload from 2 separate supplies.

    TBC 9-22-00 nn FPL 141 3561 R nn 00 nn 22 20 0.54TBC 16-22-00 nn FPL 181 3561 R nn 00 nn 28 25 0.54TBC 25-22-00 nn GJL 241 3561 R nn 00 nn 45 40 0.62

  • 2/251SBC 0004 99 R1001

    Low Voltage Products

    2

    TBC and TAE Contactorswith Large Coil Voltage RangeD.C. Operated - A.C. Circuit Switching

    Mounting positions: Add-on accessoriesContactors Max. number of auxiliary contact blocks Timer Interlock Function

    CA5-10 CA5-01 CA5-40 CA5-31 CA5-22 CA5-04 TP - A unit markerpos. 1, 3 or 4TBC - 30 - 00TBC - 30 - 10 4 2 1 1 1 VBC 30 BA 5-50TBC - 40 - 00pos. 1, 3 or 4TBC - 30 - 01 4 1 1 1 VBC 30 BA 5-50pos. 1, 3 or 4TBC - 22 - 00 4 1 VBC 30 BA 5-50pos. 1 30TBC - all types VBC 30 BA 5-50all positionsTAE - 6 6 1 1 1 1 1 VE5-2 (1) BA 5-50

    (1) Only valid for TAE 50-30-00 and TAE 75-30-00.

    Note: Railway (traction) projects on request.For selection and use of surge suppressors (e.g. diodes, varistors, etc.) with TBC contactorssee notes p. 4/14.

    Coil CharacteristicsNo extra voltages applicable on the Uc min. - max. values of the Coil Voltage table, page 2/24.

    Coil consumption at Uc max. and = 20 C:- 9 W pull-in/holding for TBC type- 450 W pull-in/ 7 W holding for TAE 50 and TAE 75 types- 950 W pull-in/ 7 W holding for TAE 95 and TAE 110 types

    Replacement coils: please consult us (standard BC and AE contactor coils are not suitable for TBC and TAEcontactors).

    "Mounting Distance" for coil operating limits Uc min. - Uc max.d D Ambient temp. Max. switching frequency

    mm mm C Operating cycles/h2 20 20 12005 20 55 1200

    Technical DataIdentical to standard BC and AE contactor data (see page 2/38) except: Air temperature close to contactor: 55 C max. Shock withstand in position 1 for contactors screwed on their support and without N.C. add-on aux. contact block.

    1/2 sinusoidal shock for 11 ms: no change in contact positionShock direction A B1 B2 C1 C2

    Making TBC 15 g* 10 g 10 g 10 g 10 gposition TAE 20 g 10 g 15 g 20 g 20 g

    Breaking TBC 10 g 5 g** 6 g*** 4 g 4 gposition TAE 20 g 5 g 15 g 20 g 20 g

    Exceptions: *12g for TBC 30-30-00 ; **4g for TBC 16-22-00 ; ***5g for TBC 25-30-01

  • Low Voltage Products1SBC 0004 99 R10012/26

    GeneralThe AF contactors have the same appearance and same dimensions as the a.c. operated A contactors of equalrating.They are fitted with an electronic coil interface. For a given coil, this interface allows the contactor toaccept a wide control voltage range in d.c. as well as in a.c., 50 or 60 Hz.The current flow through the coil is a regulated d.c. current and is therefore independent from the control voltagelevel and frequency.Operating advantages : The device withstands large control voltage variations without nuisance reopening. Reduced holding coil consumption. Noiseless working: d.c. regulated coil. Pull-in and drop-out voltages are clearly defined.AF contactors comply with international standards IEC 947-1, 947-4-1 and European standardsEN 60 947-1, 60 947-4-1. Moreover, in environment 2, they meet the electromagnetic compatibility rules(EMC) : amendment A11 for IEC 947-1 and amendment 2 for IEC 947-4-1.Using these materials in environment 1 may lead to radio-interferences requiring the use of additional mitigationmethods.Here are the definitions given in the amendment A11 to standard EN 60 947-1.Environment 1 : "Mainly relates to low-voltage public networks (see EN 50 082-1 article 5) such as residential,commercial and light industrial locations/installations. Highly disturbing sources such as arc welders are notcovered by this environment".Environment 2 : "Mainly relates to low-voltage non public or industrial networks/locations/installations(see EN 50 082-2 article 4) including highly disturbing sources".

    Block diagram and operating diagram

    SB73

    92S3

    SB74

    06S5

    AF Contactors - a.c. / d.c. operatedwith controlled supplya.c. circuit switching

    Technical dataType AF 45 AF 75 AF 95, AF 110

    Max. electrical switching frequency cycles/h 600 600Coil consumption - pull-in a.c. VA 210 450

    - pull-in d.c. (U min./U max.) W 135/210 290/450- holding a.c. VA/W 5/1.5 11/3- holding d.c. W 1.5 3

    Operating timeBetween coil energization and : - N.O. contact closing ms 20 45 25 40

    - N.C. contact opening ms 17 40 22 37Between coil de-energization and : - N.O. contact opening ms 40 70 60 120

    - N.C. contact closing ms 45 75 65 125

    AF 95-30

    AF 95-30

  • 2/271SBC 0004 99 R1001

    Low Voltage Products

    2

    Coil voltages :Rated control Codevoltage Uc :d.c., 50 and 60 Hz a.c.

    V .............. V nn nn58 ............ 92 6 490 .......... 130 6 5

    100 .......... 160 6 6150 .......... 240 6 7

    Operating limits 0.85 ... 1.1 x Uc

    AF Contactors - a.c. / d.c. operatedwith controlled supplya.c. circuit switching

    Ordering details, 3-pole contactorsType Order code Mounted Rated operational Motor power AC-3 WeightState coil to be completed with coil auxiliary current 220 V 380 V in kgvoltage : nn voltage code : nn nn contacts AC -1 AC-3 230 V 400 V 415 V 690 V

    40C 400 V 240 V PackingSee table opposite See table opposite A A kW kW kW kW 1 piece

    AF 50-30-00 nn 1SBL 35 7001 R nn n n 00 100 50 15 22 25 30 1.180AF 50-30-11 nn 1SBL 35 7001 R nn n n 11 1 1 100 50 15 22 25 30 1.220AF 63-30-00 nn 1SBL 37 7001 R nn n n 00 115 65 18.5 30 37 37 1.180AF 63-30-11 nn 1SBL 37 7001 R nn n n 11 1 1 115 65 18.5 30 37 37 1.220AF 75-30-00 nn 1SBL 41 7001 R nn n n 00 125 75 22 37 40 40 1.180AF 75-30-11 nn 1SBL 41 7001 R nn n n 11 1 1 125 75 22 37 40 40 1.220AF 95-30-00 nn 1SFL 43 7001 R nn n n 00 145 96 25 45 55 55 2.030AF 95-30-11 nn 1SFL 43 7001 R nn n n 11 1 1 145 96 25 45 55 55 2.070AF 110-30-00 nn 1SFL 45 7001 R nn n n 00 160 110 30 55 59 75 2.030AF 110-30-11 nn 1SFL 45 7001 R nn n n 11 1 1 160 110 30 55 59 75 2.070

    Ordering details, 4-pole contactorsType Order code Mounted Rated operational current WeightState coil to be completed with coil auxiliary in kgvoltage : nn voltage code : nn nn contacts AC -1 AC-1

    40C 55C PackingSee table opposite See table opposite A A 1 piece

    4 N.O. main poles :

    AF 45-40-00 nn 1SBL 33 7201 R nn nn 00 70 60 1.420AF 50-40-00 nn 1SBL 35 7201 R nn nn 00 100 85 1.420AF 75-40-00 nn 1SBL 41 7201 R nn nn 00 125 105 1.420

    2 N.O. and 2 N.C. main poles :

    AF 45-22-00 nn 1SBL 33 7501 R nn nn 00 70 60 1.420AF 75-22-00 nn 1SBL 41 7501 R nn nn 00 125 105 1.420

    These contactors can be used for controlling either 2 separate circuits, i.e. 2 loads with 2 separate supplies,or 1 circuit comprising 2 separate loads with 1 single supply (see diagrams below).When the contactor operates, there is no mechanical overlapping between the N.O. main polesand N.C. main poles : Break before Make.

    These contactors are not suitable for a reversing starter or a star-delta starter or for controlling a singleload from 2 separate supplies.

    l 1 single supply and 2 separate loads l 2 separate supplies and 2 separate loads

    Accessories (section 4)AF 45 AF 110 contactor accessories are the same as those