22
JAS-ANZ ISO 9001 : 2000 GIAÁY CN SOÁ: HT.059/1.03.19 VIETNAM ELECTRICAL EQUIPMENT JOINT STOCK CORPORATION ELECTRICAL EQUIPMENT JOINT STOCK COMPANY TỔNG CÔNG TY CỔ PHẦN THIẾT BỊ ĐIỆN VIỆT NAM CÔNG TY CỔ PHẦN THIẾT BỊ ĐIỆN THIBIDI TRADING JOINT STOCK COMPANY CÔNG TY CỔ PHẦN KINH DOANH VẬT TƯ THIBIDI KIOSK - TYPE PACKAGE TRANSFORMER SUBSTATION TRẠM BIẾN ÁP HỢP BỘ KIỂU KIOSK

Catalogue Tram Bien AP Hop Bo Kieu Kiosk

Embed Size (px)

DESCRIPTION

GEREQRG

Citation preview

  • JAS-ANZ

    ISO 9001 : 2000GIAY CN SO: HT.059/1.03.19

    VIETNAM ELECTRICAL EQUIPMENT JOINT STOCK CORPORATION

    ELECTRICAL EQUIPMENT JOINT STOCK COMPANY

    TNG CNG TY C PHN THIT B IN VIT NAM

    CNG TY C PHN THIT B IN

    THIBIDI TRADING JOINT STOCK COMPANYCNG TY C PHN KINH DOANH VT T THIBIDI

    KIOSK - TYPE PACKAGE TRANSFORMER SUBSTATIONTRM BIN P HP B KIU KIOSK

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 03

    LI GII THIU / INTRODUCTION

    Li u tin, Chng ti xin chn thnh cm n Qu khch hng quan tm, h tr v s dng vt t, thit b, dch v m Chng ti cung cp trong thi gian qua. Chc Qu khch hng lun di do sc khe, hnh phc v thnh cng.

    Cng ty C phn Kinh Doanh Vt T THIBIDI (tn thng mi l TTC) c thnh lp vo ngy 01/07/2008 trn c s l cng ty con ca Cng ty C Phn Thit B in (THIBIDI) n v thnh vin trc thuc Tng Cng ty Thit B in Vit Nam (GELEX).

    TTC lin kt vi THIBIDI thit k v sn xut sn phm Trm bin p hp b kiu kiosk mang thng hiu TTC. Ngoi ra TTC cn cung cp cc sn phm khc bao gm: My bin th THIBIDI, dy cp in CADIVI, sn phm cng t EMIC v thit b in h th, trung th

    Cng vi s nhit tnh, tm huyt ca Ban Gim c v i ng nhn vin chuyn nghip, Qu khch hng s c phc v v gii php k thut, tin giao hng, gi c v ch hu mi tt nht. TTC cam kt s mang li nhng quyn li ti u nht cho qu khch hng.

    Trn trng knh cho!

    Firstly, we would like to give our most sincere appreciation to your attention, assistance and use of our supplied materials, equipments, services during last time. Wish you always have good health, happiness and success.

    THIBIDI Trading Joint Stock Company (trade name, TTC) was incorporated on 01 July 2008 upon the basis of the Subsidiary of Electri-cal Equipment Joint Stock Company (THIBIDI) the member unit directly under Vietnam Elec-trical Equipment Joint Stock Corporation (GELEX).

    TTC has cooperated with THIBIDI for designing and manufacturing Kiosk - type Pack-age transformer Substation with TTC trade name. TTC also provides other products include: THIBIDI power transformer, CADIVI electrical cables, products of EMIC meter and low-voltage, medium-voltage equipments and etc.

    With the enthusiasm, whole-heartedness of the Board of Directors and the professional team of employees, Customers shall be served best in techniques solutions, progress of delivery, price and after-sales regimes. TTC commits to bring you the best optimal rights.

    Yours sincerely!

  • NI DUNG / CONTENTS

    TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 04

    Tng quan / General 5

    ng dng / Applications

    u im / Advantages

    iu kin lp t / Conditions of installation

    Gii php thit k / Design solutions 7

    Kiu trm / Substation type

    Kch thc trm / Dimensions

    Thit k v Ch to / Design & Fabrication 10

    V trm / Enclosure

    Chn / Base frame

    Thn trm / Substation body

    Mi / Roof

    H thng thng gi / Ventilation system

    Mng cp / Cable cellars

    H thu du / Oil collecting pit

    c tnh k thut TTC-KPS / TTC-KPS Specifications 15

    Thng s k thut chung / General technical parameters

    Thit b bn trong TTC-KPS / Electrical equipments in the TTC-KPS 16

    My bin p / Transformer

    Thit b ng ct v bo v pha trung th / Medium-voltage switchgear

    Thit b ng ct v bo v pha h th / Low-voltage switchboard

    Cp v ph kin / Cable and accessories

    Th nghim / Testing 19

    Th nghim cc thit b bn trong trm / Test of electrical equipments inside substation

    Th nghim trm TTC-KPS / Test of TTC-KPS

    Qun l cht lng / Quality control 21

    An ton cho ngi / Safety for people

    Chng n mn v tc ng ca kh hu / Anti-corrosion and environmental impact

    Hng dn bo tr /

  • TNG QUAN / GENERAL

    TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 05

    Trm bin p hp b kiu kiosk do Cng Ty C Phn Kinh Doanh Vt T THIBIDI (TTC-KPS) thit k, sn xut v th nghim theo tiu chun IEC 62271-202.

    Trm bin p hp b kiu kiosk bao gm v trm c cha my bin p phn phi, thit b ng ct v bo v pha trung, h th, h thng o lng, dy cp v ph kin m bo vic cung cp in nng an ton.

    Kiosk - type Package transformer Substation designed, manufactured and tested in accordance with IEC 62271-202 standard by THIBIDI Trad-ing Joint Stock Company (TTC-KPS).

    Kiosk - type Package transformer Substa-tion includes Substation enclosure containing the distribution transformers, medium-voltage (MV) switchgear, low-voltage (LV) switchboard, measurement system, cables and accessories to ensure the safe energy supply.

    ng dng: TTC-KPS c ch to sn lp t ngoi tri, ti nhng ni cng cng, trm khch hng c li in ngm m bo an ton cho ngi vn hnh v xung quanh:

    Trm phn phi cp ngun

    Trm phn phi khch hng

    Trm phn phi khu dn c

    Trm phn phi cho chiu sng cng cng

    Applications: Prefabricated TTC-KPS shall be installed outdoor, at the public places, the customer Substation includes the underground grid to ensure the operators and general public:

    Distribution Substation for power supply

    Distribution Substation for customers

    Distribution Substation for residential areas

    Distribution Substation for public lighting

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 06

    TNG QUAN / GENERAL

    Advantages: With the prefabricated design, TTC-KPS brings you the following benefits:

    Safety for operators and general public

    Improving the reliability of electric power quality

    Prefabricated, easy and quick for instal-lation

    Protecting transformer outstandingly, ensuring the lifetime of equipments

    Saving the installation space

    Needing to be a little bit of infrastructure item, low installation cost

    Increasing the aesthetics for site area

    Conditions of installation:

    Altitude: Not exceeding 1000m

    The maximum temperature of the ambient air: 50 C

    The minimum temperature of the ambient air: -5 C

    The average temperature of the ambient air: 30 C

    The highest humidity: 95%

    Climate: Tropical

    0

    0

    0

    u im: Vi thit k ch to sn, TTC-KPS mang n cho Qu Khch hng nhng li ch sau:

    An ton cho ngi vn hnh v ngi xung quanh

    Ci thin tin cy cht lng in

    Ch to sn, thi cng lp t d dng, nhanh chng

    Bo v my bin p vt tri, m bo tui th thit b

    Tit kim khng gian lp t

    Cn t hng mc h tng, chi ph lp t thp

    Tng tnh m quan ca khu vc

    iu kin lp t:

    cao tuyt i: khng vt qu 1000m

    Nhit ln nht ca mi trng xung quanh: 50 C

    Nhit nh nht ca mi trng xung quanh: -5 C

    Nhit trung bnh ca mi trng xung quanh: 30 C

    m ln nht: 95%

    Kh hu: nhit i

    0

    0

    0

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 07

    GII PHP THIT K / DESIGN SOLUTIONS

    Trm TTC-KPS lp t ngoi tri, c cng sut

    my bin p ln n 2x1250kVA, vn hnh t

    bn ngoi trm, c v bng kim loi sn tnh

    in hoc m km nhng nng.

    Trm TTC-KPS c sn xut v th

    nghim ti TTC-THIBIDI sn sng cho vic lp

    t, vn hnh. Chng ti cung cp nhng gii

    php thit k ti u ph hp vi yu cu Khch

    hng, bao gm kiu trm chun TTC-KPS.W,

    kiu trm TTC-KPS.L cho v tr t trm hp,

    kiu trm TTC-KPS.D cho trm c cng sut ln

    hn 1250kVA.

    Outdoor installed TTC-KPS substation, the

    capacity of transformer up to 2x1250kVA, oper-

    ated from outside to the substation, its metal

    enclosure is coated by electroplated painting or

    hot dipped galvanized steel.

    TTC-KPS substation is manufactured and

    tested at TTC-THIBIDI ready for installation,

    operation. We supply the optimal design

    solutions appropriate to the Customers request,

    including TTC-KPS.W (typical substation)

    ,TTC-KPS.L (substation type for narrow site

    areas), and TTC-KPS.D (substation type for

    substation with capacity higher than 1250kVA).

    Kiu trm TTC-KPS.W / TTC-KPS.W substation type

    TTC-KPS.W1 1201

    1201: Serial No. of the product / S serial sn phm

    W1: Arrangement type & capacity gram of transformers / Kiu b tr & gam cng sut my bin p

    TTC: THIBIDI Trading Joint Stock Company / Cng ty CP Kinh doanh Vt t THIBIDI

    KPS: Kiosk - type Package transformer Substation / Trm bin p hp b kiu kiosk

    LO

    W -

    VO

    LTA

    GE

    SW

    ITC

    HB

    OA

    RD

    TRA

    NSF

    OR

    MER

    ME

    DIU

    M -

    VO

    LTA

    GE

    SW

    ITC

    HB

    OA

    RD

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 08

    GII PHP THIT K / DESIGN SOLUTIONS

    Kiu trm TTC-KPS.L

    TTC-KPS.L substation type

    Kiu trm TTC-KPS.D

    TTC-KPS.D substation type

    LOW

    -V

    OLT

    AG

    ESW

    ITC

    HB

    OA

    RD

    TRANSFORMER

    MED

    IUM

    -V

    OLT

    AG

    ESW

    ITC

    HB

    OA

    RD

    TRANSFORMER

    LOW

    -V

    OLT

    AG

    ESW

    ITC

    HB

    OA

    RD

    MED

    IUM

    -V

    OLT

    AG

    ESW

    ITC

    HB

    OA

    RD

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 09

    GII PHP THIT K / DESIGN SOLUTIONS

    Kch thc trm / Dimensions

    Kiu trm / Substation types

    Cng sut my bin p/ Power transformer

    Chiu di / LengthL (mm)

    Chiu rng / WidthW (mm)

    Chiu cao / HeightH (mm)

    TTC-KPS.W1

    TTC-KPS.W2

    TTC-KPS.W3

    TTC-KPS.W4

    TTC-KPS.L1

    TTC-KPS.L2

    TTC-KPS.L3

    TTC-KPS.L4

    TTC-KPS.D1

    TTC-KPS.D2

    TTC-KPS.D3

    n / up to 180kVA

    n / up to 400kVA

    n / up to 800kVA

    n / up to 1250kVA

    n / up to 180kVA

    n / up to 400kVA

    n / up to 800kVA

    n / up to 1250kVA

    n / up to 2x800kVA

    n / up to 2x1000kVA

    n / up to 2x1250kVA

    2830

    3060

    3260

    3560

    2950

    3580

    3860

    4290

    3860

    4210

    4290

    1550

    2080

    2260

    2490

    1530

    1660

    1760

    1860

    3510

    3550

    3710

    1890

    2020

    2130

    2380

    1990

    2120

    2230

    2480

    2230

    2400

    2480

    H

    WL

  • V trm

    Kiu thit k chun TTC-KPS.W gm ba ngn:

    Ngn trung th lp t t ng ct v bo v trung th

    Ngn my bin th lp t my bin th phn phi THIBIDI

    Ngn h th lp t t in h th, h thng o lng.

    V trm bao gm cc phn c lin kt vi nhau bng bulong, m bo chc chn, c th tho ri c bao gm: Chn , thn trm v mi.

    V trm c sn tnh in mu xm nht.

    V trm m bo chng thm nc khi t ngoi tri, cp bo v ca v trm t IP23D theo tiu chun IEC 60529 (cp bo v ca ca trm c th t IP54 ty theo yu cu Khch hng).

    TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 10

    TTC-KPS c thit k, ch to, th nghim sn ti nh my thnh mt khi m bo an ton v thm m.

    TTC-KPS c sn xut trn cng ngh, my mc hin i.

    TTC-KPS is designed, fabricated and tested ready in the factory to form a block of safety guarantee and aesthetics.

    TTC-KPS is manufactured by the modern technology and machines.

    Enclosure

    TTC-KPS.W is typical design include three compartments:

    MV compartment: installed MV switchgear and controlgear.

    Transformer compartment: installed THIBIDI distribution transformer.

    LV compartment: installed LV switchgear and controlgear, measurement equip-ments.

    Enclosure includes the parts are jointly associated by bolts, to ensure the certainty and removable, including: base frame, substation body and roof.

    Enclosure is coated by light grey electro-plated painting.

    Enclosure ensures the waterproof when installed outdoor, degree of protection of the enclosure achieves IP23D in accordance with IEC 60529 standard (the degree of protection of the substation doors can achieve IP54 depend-ing on the Customers request).

    THIT K V CH TO / DESIGN & FABRICATION

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 11

    Chn

    L khung chu lc ton b vt t thit b ca trm. c lm bng thp nh hnh hoc thp tm c dy ti thiu 3mm ty theo tng trng hp c th, tt c c hn ngu vi nhau thnh mt khi v c m km nhng nng, mt ngoi chn c sn mu en tng tnh thm m.

    Bn mc cu lin kt vi chn bng bulong chc chn, m bo chu c lc nng ca ton b trm khi bc d. Mc cu c th tho ri khi cn thit lm tng tnh thun tin v m quan.

    Chn c thit k sn cc cht bt bulong nh v trm xung nn mng.

    C ba v tr tip a khung chn , c b tr trong ngn trung th, ngn my bin th, ngn h th. V tr tip a lm bng bulong INOX M12 c hn ngu vo khung chn m bo dn in tt.

    Base frame

    It is load-bearing for supporting all materi-als and equipments of the substation. It is made of shape steel or steel plate with its minimum thickness of 3mm depending on each specific case, they all are welded to one block and hot-dip galvanized, the outer side of base frame is painted black to intensify the aesthetics.

    Four lifting hooks are associated with base frame by bolts certainly, to ensure the lift force bearing of the entire transformer substation when loading. Lifting hooks can be removable to improve the convenience and aesthetics.

    Base frame is pre-designed to join bolts to locate the substation into the foundation.

    There are three points earthing locations in base frame, they are arranged in the MV compartment, transformer compartment, LV compartment. The earthing location by INOX M12 bolts is welded to the base frame to ensure the good conduct.

    Thn trm Substation body

    THIT K V CH TO / DESIGN & FABRICATION

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 12

    THIT K V CH TO / DESIGN & FABRICATION

    Thn trm bao gm cc tm xung quanh, ca trm, vch ngn, t in h th. Lin kt vi trm bng bulong m bo chc chn v to thnh khung cng, t ng.

    Cc tm xung quanh: lm bng thp tm dy 2mm, l v tr lp bn ca ca bn mt xung quanh. Lin kt vi ca trm, vch ngn, t in h th bng bulong. Chng c thit k lp rp t bn trong, chng tho t bn ngoi.

    Vch ngn c lm bng thp tm 1,5mm. C hai tm vch ngn: vch ngn gia ngn trung th v ngn my bin th; vch ngn gia ngn my bin th v ngn h th. Vch ngn c gi cp trung th v h th.

    Ca trm lm bng thp tm 2mm, c thit k t IP23D, m bo ng kht, thao tc d dng v kn nc. Ph kin lp t ca nh bulong, bn l, kha ca l loi ngoi tri, lm bng thp khng r hoc xi m chng r st.

    T in h th c t trong ngn h th, lm bng thp tm 1,5mm, c lin k vi vch ngn v chn t in h th bng bulong, cc bulong ny ch c tho t bn trong t in h th. Ngn lp my ct h th tng v my ct l ra ph ti (nu c yu cu). Ca c kha chm, bt kha, lp h thng hin th: volt k, amper k, n bo pha.

    Mt y trm c cc kt cu cho php cp u vo v ra t.

    Ton b thn trm c lm bng thp tm, sn tnh in loi ngoi tri c hai mt trong v ngoi.

    Substation body includes the surrounding plates, substation doors, partition, LV panel. Associ-ated with the base frame by bolts to ensure certainty and form the firm frame, supporting its self.

    Surrounding plates: They are made of steel plate of 2mm thick, it is the location to install four doors of four surrounding sides. Associated with the Substation doors, partitions, LV panel by bolts. They are designed to assemble from the inside, and non-removable from the outside.

    Partitions are made of the steel plate of 1.5mm thick. There are two partition plates: one to divides MV compartment and transformer compartment; and one to divides transformer compartment and LV compartment. Partitions includes cable supports medium-voltage and low-voltage.

    Substation doors is made of steel plate of 2mm thick, designed to achieve IP23D, ensure the closure, operate easily and watertight. Accessories for installing doors such as bolts, hinge joints, door locks used the outdoor type, it is made of the stainless steel or plating for corrosion protection.

    Low-voltage panel is installed in the LV compartment, it is made of steel plate of 1.5mm thick, associated with the partition and base of LV panel by bolts, these bolts are removed from the inside of the LV panel. Compartment for installing the main LV circuit breaker and feeder circuit break-ers (if requested). Doors include the dead lock, lock bracket, installation of the display system: voltmeter, amperemeter, indicator phase light.

    The bottom side of substation has the struc-tures for cable connected in and out the panels.

    Substation body is made of steel plate, electroplated painting of outdoor type both inside and outside.

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 13

    THIT K V CH TO / DESIGN & FABRICATION

    Mi

    Lm bng thp tm 2mm, sn tnh in ngoi tri c hai mt trong v ngoi.

    Mi c chia thnh ba phn tng ng vi ba ngn: mi ngn trung th, mi ngn my bin th v mi ngn h th. Chng c lin kt vi nhau v lin kt vi thn trm bng bulong m bo cng vng.

    C th tho lp c, ti mi phn mi u c hai bt cu mi khi tho lp.

    C dc ti thiu 2% m bo khng ng nc trn mi.

    Roof

    It is made of steel plate of 2mm thick, electro-plated painting of outdoor type both inside and outside.

    Roof is divided into three respective parts to three compartments: roof for MV compartment, roof for transformer compartment and roof for LV compartment. They are associated together and linked to the substation body by bolts to ensure the stability.

    Removable, at each roof part includes two brackets for roof lifting when assembly.

    Minimum slope is 2% to ensure not water stagnant on roof.

    H thng thng gi t nhin ca trm c thit k m bo tui th cc thit b trong trm trong iu kin vn hnh bnh thng. Cp v trm: class 20, trm cng c thit k t cp v trm: class 5, class 10, class 15 ty theo yu cu ca khch hng.

    Natural ventilation system of the substation is designed to ensure the life time for equipments in the substation in the condition of normal operation. Class of enclosure: class 20, the substation is also designed to achieve the class of enclosure: class 5, class 10, class 15 depending on the customers request.

    H thng thng gi Ventilation system

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 14

    Cp v trm l chnh lch nhit ca my bin p khi lp bn trong trm v bn ngoi trm, l ch s xc nh h s ti ca my bin p trong trm, t xc nh cng sut ln nht ca trm bin p hp b kiu kiosk (xem ph lc D trong tiu chun IEC 62271-202).

    H thng thng gi bao gm thng gi thn v thng gi mi. Thng gi thn lm bng nhm hoc thp tm dy 1,5mm, m km nhng nng trc khi sn tnh in v nh v vo ca trm/thn trm trnh r st, m bo m quan. Thng gi mi m bo khng kh i lu t nhin tt hn.

    Mng cp: Mng cp c b tr sn trong nn mng trm thun li cho vic thi cng cp ngm vo v ra khi trm.

    H thu du: bo v mi trng, nn mng trm TTC-KPS phi c h thu du theo qui nh ca in lc. Trong trng hp trm TTC-KPS lp my bin p kh hoc my bin p ngm du thn thin mi trng, du FR3 th khng cn h thu du.

    Class of enclosure is the difference in tempera-ture of transformer when installed inside and outside the substation, it is the indicator to deter-mine the loading factor of tranformer in the substa-tion, since hence, the highest capacity of the Kiosk - type Package transformer Substation shall be deter-mined (please refer to Annex D in IEC 62271-202 standard).

    Ventilation system includes ventilation for body part and roof as well. Ventilation for body part is made of aluminium or steel of 1.5mm thick, hot dipped galvanized steel before electroplated painting and locating to the substation doors/ substation body to avoid the iron rust, and ensure the aesthetics. Ventilation for roof aims at ensuring the better natu-ral convection air.

    Cable cellars: Cable cellars are pre-arranged in the foundation of substation for facilitating construction of underground cable in and out from the substation.

    Oil collecting pit: In order to protect the environment, the foundation of TTC-KPS substation must include oil collecting pit in accordance with the stipulations of Power Branch. In case, TTC-KPS substation installs the dry-type transformer or oil-immersed transformer friendly with environment FR3 oil, it isnt required for oil collecting pit.

    THIT K V CH TO / DESIGN & FABRICATION

  • General technical parameters

    Rated medium-voltage: 22kV

    Rated low-voltage: 0.4kV

    Number of phases: 3 phases

    Rated frequency: 50Hz

    Sound level: 50dB

    Short-circuit current and peak current on earthing circuit: 3kA in 1s

    Rated class of enclosure: Class 20

    Degree of protection of the enclosure: IP 23D

    + Transformer compartment: IP 23D

    + MV compartment: IP 23D

    + LV compartment: IP 23D

    Internal arc classification: IAC-AB

    + Rated short-time withstand current: 20kA/1s

    Rated insulation levels:

    + Rated short-duration power-frequency withstand voltage : 50kV in 1 minute

    + Rated lightning impulse withstand voltage: 125kV (1,2/50)s

    Connecting cable in MV side: MV under-ground cable is 24kV copper wire to link from transformer to MV switchgear.

    Connector in MV side: Connector of expo-sure MV cable to be supplied depending on the customers request.

    LV panel is connect to transformer: By cable / copper busbar, cosse connector with the appropriate size with the transformers capacity.

    Mechanical impact test: 20J

    TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 15

    C TNH K THUT TTC-KPS / TTC-KPS SPECIFICATIONS

    Thng s k thut chung

    in p nh mc trung th: 22kV

    in p nh mc h th: 0,4kV

    S pha: 3 pha

    Tn s nh mc: 50Hz

    Mc n: 50dB

    Dng ngn mch v dng nh trn mch ni t: 3kA trong 1s

    Cp v trm nh mc: Class 20

    Cp bo v ca v trm: IP 23D

    + Ngn my bin th: IP 23D

    + Ngn trung th: IP 23D

    + Ngn h th: IP 23D

    An ton khi c s c pht sinh h quang bn

    trong t trung th: IAC-AB

    + Kh nng chu dng s c: 20kA/1s

    Mc cch in nh mc

    + in p chu ng tn s cng nghip: 50kV trong 1 pht

    + in p chu ng xung st: 125kV (1,2/50)s

    Ni cp pha trung th: cp ngm trung th

    l dy ng 24kV, lin kt my bin p vi t

    trung th.

    u ni pha trung th: u ni cp trung th

    l vo c cung cp ty theo yu cu ca khch

    hng.

    H th c ni n my bin p: bng cp

    / thanh ci ng, u cosse c kch c ph hp vi cng sut my bin p.

    Th va p c hc: 20J

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 16

    Vic la chn thit b lp trong TTC-KPS l

    mt vn quan trng nh hng n cht lng

    ca TTC-KPS.

    Mi thit b khi a vo lp t u phi c

    chng minh ngun gc xut x, t tiu chun th

    nghim in hnh theo quy nh ca tng thit b .

    My bin p

    My bin p c s dng trong TTC-KPS

    c sn xut bi Cng Ty C Phn Thit B

    in (THIBIDI).

    Thng s k thut my bin p

    Cng sut nh mc: t 30kVA n

    2x1250kVA

    in p nh mc: 15 (22) / 0,4kV

    Loi: bin p ngm du, lm mt t nhin

    S pha: 3 pha

    Tn s nh mc: 50Hz

    S xuyn trung th: s plug-in

    Cp cch in: A

    Thng s tn hao: Tn hao c ti, tn hao

    khng ti, dng in khng ti, ngn mch tr

    khng: theo tiu chun in lc a phng.

    Transformer

    Transformer is used in TTC-KPS manufac-

    tured by Electrical Equipment Joint Stock Com-

    pany (THIBIDI).

    Technical parameters of transformer

    Rated power: From 30kVA to 2x1250kVA

    Rated voltage: 15 (22) / 0,4kV

    Type: Oil transformer, natural cooling

    Number of phases: 3 phases

    Rated frequency: 50Hz

    MV bushing: Plug-in bushing

    Insulation level: A

    Loss parameters: Load loss, non-load

    loss, non-load current, short-circuit impedance:

    Based on the standard of local Power Compa-

    nies.

    Selecting the equipment for installation in

    TTC-KPS is the important matter affecting the qual-

    ity of TTC-KPS.

    When putting into installation, each equipment

    must be demonstrated its origin and achieve the

    type-test as specified for such equipment.

    THIT B BN TRONG TTC-KPS / ELECTRICAL EQUIPMETS IN THE TTC-KPS

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 17

    Thit b ng ct v bo v pha trung th

    Thng s k thut ca thit b ng ct v bo v

    pha trung th:

    in p nh mc: 24kV

    Dng in nh mc

    + L mch chnh (l vo): 400A 630A

    + L my bin p (l ra) bo v bng ch

    trung th: 200A 630A

    Kh nng chu dng ngn mch: 20kA/1s

    hoc 20kA/3s

    Tn s nh mc: 50Hz

    Nhn hiu t trung th: Schneider,

    Siemens,

    Medium-voltage switchgear

    Technical parameters of MV switchgear:

    Rated voltage: 24kV

    Rated current

    + Network switch: 400A 630A

    + Transformer feeder combined MV fuse-switch: 200A 630A

    Rated short-time withstand current: 20kA/1s

    or 20kA/3s

    Rated frequency: 50Hz

    Brand of MV switchgear: Schneider,

    Siemens,

    Thit b ng ct v bo v pha h th

    Thng s k thut ca my ct h th:

    in p nh mc: 400V

    Dng in nh mc: 50A 2000A

    S cc: 3 4 cc

    Tn s: 50Hz

    Loi my ct: MCCB hoc ACB

    Kh nng chu dng ngn mch: t 25kA n

    75kA

    Nhn hiu my ct h th: Schneider, Mitsubi-shi, LS, Hyundai,

    Low-voltage switchboard

    Technical parameters of LV circuit breaker

    Rated voltage: 400V

    Rated current: 50A 2000A

    Number of pole: 3 to 4 poles

    Frequency: 50Hz

    Circuit breaker type: MCCB or ACB

    Circuit short-current capacity: From 25kA to

    75kA

    Brand of LV circuit breaker: Schneider,

    Mitsubishi, LS, Hyundai,

    THIT B BN TRONG TTC-KPS / ELECTRICAL EQUIPMETS IN THE TTC-KPS

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 18

    Cp v ph kin

    TTC-KPS c cung cp km theo cc loi cp sau:

    S dng cp ngm trung th 24kV kt ni my bin p qua t trung th bng u ni cp ngm trung th dng elbow.

    Cp hoc thanh ci ng h th ni t my bin p qua my ct h th.

    Cung cp u ni cp ngm l vo nu c yu cu ca khch hng.

    Cable and accessories

    TTC-KPS is supplied in attachment to the following types of cable:

    Using MV underground cable 24kV to connect to transformer through MV panel by connector of MV underground in elbow type.

    LV cable or copper busbar connected from transformer through LV panel

    Supplying the connector of in-exposure underground cable if requested by customer.

    THIT B BN TRONG TTC-KPS / ELECTRICAL EQUIPMETS IN THE TTC-KPS

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 19

    Th nghim cc thit b bn trong trm:

    Tt c cc thit b bn trong trm TTC-KPS c th nghim theo tiu chun ring.

    Thit b ng ct v bo v trung th, th nghim theo IEC 62271-200

    My bin p phn phi, th nghim theo TCVN 6306, IEC 60076

    Thit b ng ct v iu khin h th, th nghim theo IEC 60439

    Th nghim trm TTC-KPS

    Trm bin p hp b kiu kiosk, TTC-KPS, c th nghim theo tiu chun IEC 62271-202, theo cc hng mc th nghim sau:

    Th nghim thng xuyn (xut xng)

    Mi trm TTC-KPS c kim tra th nghim t yu cu xut xng ti phng th nghim cao p t chun VILAS ca Cng Ty C Phn Thit B in (THIBIDI), cc hng mc th nghim xut xng:

    Th cao p tn s cng nghip 50kV trong 1 pht

    Th nghim in mi trn mch in ph

    Th nghim chc nng:

    + Hot ng ca cc thit b ng ct v iu khin

    + Hot ng c kh ca ca trm kiosk

    + Tng cng cch in

    + Kim tra nhit v mc du ca my bin p

    + Kim tra h thng hin th in p

    + B phn ni t

    Test of electrical equipments inside substation:

    All electrical equipment inside TTC-KPS substation are tested in accordance with the own standard.

    High-voltage switchgear and controlgear shall be tested according to IEC 62271-200

    Distribution transformers shall be tested according to TCVN 6306, IEC 60076

    Low-voltage switchgear and controlgear assemblies shall be tested according to IEC 60439

    Test of TTC-KPS

    Kiosk-type Package transformer Substation, TTC-KPS is tested according to IEC 62271-202 standard, to comply with the following tested items:

    Routine test

    Each checked and tested TTC-KPS substation achieve the Routine test requirements at VILAS quali-fied high voltage laboratory of Electrical Equipment Joint Stock Company (THIBIDI), the tested items before ex-works include as follows:

    Short-duration power-frequency withstand voltage test: 50kV in 1 minute

    Dielectric test on auxiliary circuits

    Functional tests:

    + Operation of the switchgear and control-gear

    + Mechanical operation of Kiosk substation doors

    + Fixing of insulating barriers

    + Checking of temperature and liquid level of the transformer

    + Voltage indication check

    + Fitting of earthing devices

    TH NGHIM / TESTING

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 20

    + Th nghim cp

    + Thay cu ch, nu c

    + Hot ng ca nc iu chnh my bin p

    + V sinh li thng gi

    + Kim tra lin ng gia cc thnh phn khc nhau, nu c

    Kim tra mch u dy

    Th nghim lin ng khng ti

    + Cable testing

    + Replacement of fuses, if applicable

    + Operation of the transformer tap-changer

    + Cleaning of ventilation grids

    + If there are interlocks between different components, their function shall be tested.

    Verification of correct wiring

    Non-load inter-test

    Th nghim in hnh

    Th nghim in mi i vi phn kt ni gia thit b ng ct v bo v trung th vi my bin th v gia my bin th vi bng in h th

    Th tng nhit

    Th nghim kh nng chu ng dng nh nh mc v dng chu ng thi gian ngn nh mc ca mch chnh v mch ni t

    Th cc chc nng

    Kim tra cp bo v

    Th nghim bn c hc

    Th nghim an ton khi c s c pht sinh h quang bn trong t trung th

    Kim tra tng thch in t EMC

    Kim tra n

    Type test

    Dielectric test for connection between MV switchgear with transformer and between trans-former with LV panel

    Test to prove temperature rise

    Tests to prove the capability of the main and earthing circuits to be subjected to the rated peak and the rated short-time withstand currents

    Functional tests

    Tests to verify the degree of protection

    Test of mechanical stress

    Tests to assess the effects of arcing due to an internal fault

    EMC compatibility tests

    Sound level test

    TH NGHIM / TESTING

  • TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 21

    TTC-KPS is manufactured in THIBIDI

    factory in accordance with the strict procedures

    of quality control appropriate to ISO 9001 qual-ity control standard.

    Safety for people

    TTC-KPS is designed to permit the operator

    to approach through the doors and door lock

    system.

    The MV switchgear installed in TTC-KPS is

    type of safety guarantee for operator outside the

    substation.

    Steel structure of foundation is welded for

    joint association and linked to the earthing system

    of the substation. All equipment has the metal

    cover, substation body, substation doors and

    ventilation system are connected to the earthing

    system of the substation. Ensuring all substation

    enclosure to be earthing well, ensuring high safety

    level for people;

    TTC-KPS ensures safety for operators and

    general public appropriate to IEC 62271-202

    standard.

    Anti-corrosion and environmental impact

    All TTC-KPS enclosure are covered by

    electroplated painting outdoor to ensure the corro-sion protection and corrosion impact from environ-ment. Base frame is hot dipped galvanized, outer

    side is paint black and intensifies aesthetics.

    All equipment are installed inside the substa-tion enclosure to avoid affecting directly from

    outside climate in the normal service conditions.

    In case, the substation is installed in the

    polluted areas, coastal areas, and so on, please

    contact us to be designed and manufactured in

    its own manner.

    TTC-KPS c sn xut ti nh my

    THIBIDI theo quy trnh qun l cht lng

    nghim ngt ph hp vi tiu chun qun l cht

    lng ISO 9001.

    An ton cho ngi

    TTC-KPS c thit k ch cho php ngi

    vn hnh tip cn thng qua h thng ca v

    kha ca.

    Thit b ng ct v bo v pha trung th

    c lp trong TTC-KPS l loi m bo an ton

    cho ngi vn bn ngoi trm.

    Kt cu thp ca nn mng trm c hn

    in lin kt vi nhau v c lin kt vo h

    thng tip a trm. Tt c thit b c v bng

    kim loi, thn trm, ca trm v h thng thng

    gi thn u c ni vo h thng tip a trm.

    m bo ton b v trm c ni t tt, m

    bo mc an ton cao cho ngi.

    TTC-KPS m bo an ton cho ngi vn

    hnh v ngi xung quanh ph hp theo tiu

    chun IEC 62271-202.

    Chng n mn v tc ng mi trng

    Ton b v TTC-KPS c sn tnh in

    ngoi tri m bo chng r st v tc ng n

    mn t mi trng. Chn c m km nhng

    nng, mt ngoi sn mu en tng tnh thm

    m.

    Ton b thit b c t bn trong v trm

    trnh nh hng trc tip ca kh hu bn ngoi

    trong iu kin vn hnh bnh thng.

    Trong trng hp trm c lp t ti

    nhng vng nhim, vng ven bin th hy

    lin h vi Chng ti c thit k, sn xut

    ring.

    QUN L CHT LNG / QUALITY CONTROL

  • Maintenance guide

    To work properly, the kiosk substation main-tenance work in accordance with the technical process.

    Maintenance can be preventive measures or repairs.

    eneral maintenance work including func-tional testing and cleaning.

    When performing maintenance work, to ensure compliance with all safety procedures electrical engineering.

    Around maintenance kiosk stations include:

    Check after 6 months

    - The change of ground stations

    - Ditch fills of submarine cable to land (if subsidence)

    Depending on operating conditions, the following items will be inspected and maintained regularly:

    - Removing plants, trees, grass ... that may reduce air flow by natural convection venti-lation station

    - Removing dust litter in the compartment of the kiosk substation

    - Repair scratches, dents, cracks, burst due to external

    - Check and handle the sign, warning labels if damaged

    - Test and prevent the infiltration of surface water or groundwater

    - The equipment used in the kiosk substa-tion such as low voltage switchgear, medium-voltage switchgear, transformers, metering systems..., maintenance and inspection docu-mentation on the operation and maintenance of its own for each device.

    Hng dn bo tr

    trm kiosk hot ng tt th cng tc bo tr lun tun th theo ng cc quy trnh k thut.

    Bo tr c th l bin php phng nga hoc cng vic sa cha.

    Cng tc bo tr ni chung gm chc nng kim tra v lm sch.

    Khi thc hin cng tc bo tr, phi m bo tun th theo tt c cc quy trnh an ton k thut in.

    Bo tr xung quanh trm kiosk gm:

    Kim tra sau 6 thng u

    - S thay i ca nn mng trm

    - Lp li t ca mng cp ngm (nu b st ln)

    Ty thuc vo iu kin vn hnh, cc hng mc sau s c kim tra v bo dng mt cch thng xuyn:

    - Loi b thc vt, cy, c m c th lm gim lung khng kh i lu t nhin ca h thng thng gi trm

    - Loi b rc bi bn trong cc ngn ca trm kiosk

    - Khc phc sa cha nhng try xc, vt lm, vt nc do tc ng bn ngoi

    - Kim tra v x l tm bng hiu, nhn cnh bo nu b h hng

    - Kim tra v ngn chn s xm nhp ca nc b mt hoc nc ngm

    - Cc thit b c s dng trong trm nh thit b ng ct h th, thit b ng ct trung th, my bin p, h thng o lng, bo tr v kim tra theo ti liu hng dn vn hnh v bo dng ring cho tng thit b.

    TTC cam kt s mang li nhng quyn li ti u nht cho Qu khch hngTTC commits to bring you the best optimal rights 22

    QUN L CHT LNG / QUALITY CONTROL

  • THIBIDI TRADING JOINT STOCK COMPANYCNG TY C PHN KINH DOANH VT T THIBIDI

    TTC cam ket se mang lai nhng quyen li toi u nhatcho quy khach hang

    TTC commits to bring you the best optimal rights

    a ch: ng so 9, KCN Bien Hoa 1, Bien Hoa, ong NaiAdd: Street No. 9, Bien Hoa Industrial Zone 1, Bien Hoa City, Dong Nai Province

    Tel: 061 882 6916 - 061 8830 222, Fax: 061 383 1717Website: www.thibiditrading.com - www.thibidittc.com

    Phong Ky Thuat - San Xuat:Can B6 lau 5 CC Thien Nam, 7A/162 ng Thanh Thai,P.14, Quan 10, TP. Ho Ch MinhT: 08 3868 8890 Fax: 08 3868 8891Email: [email protected]

    Chi nhanh HCM - CH Thiet B ien:65 Trieu Quang Phuc, Phng 10, Quan 5, TP. Ho Ch MinhT: 08 3857 7366, Fax: 08 3857 7368

    Chi nhanh Can Th:131 ng 3/2, Phng Hng Li, Quan Ninh Kieu, TP. Can ThT: 710 6252 121, Fax: 0710 6252 111

    Prodution Techniques:B6 floor 5 Apartment Thien Nam, 7A/162 Thanh ThaiStr., Ward 14, Dist. 10, HCM CityTel: 08 3868 8890 Fax: 08 3868 8891Email: [email protected]

    HCM Office - Electrical Stores:65 Trieu Quang Phuc Str., Ward 10, Dist. 5, HCM CityTel: 08 3857 7366, Fax: 08 3857 7368

    Can Tho Office:131 3/2 Str., Hung Loi Ward, Ninh Kieu District, Can Tho CityTel: 710 6252 121, Fax: 0710 6252 111