Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st , 2008

July 1st , 2008

CENTUM VP Installationon XP SP2

Technology Development Dept. Development GroupGlobal Engineering CenterIndustrial Automation Business Headquarters

Page 2: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Preparation

CENTUM VP Software Medium (Medium model code: LHMKM30): 1 piece

CENTUM VP Software keycode FDC (Medium model code: LHMCM30)

External DVD-ROM drive (when there is only CD-ROM drive in the PC)

For this training, copy software medium and keycode files from DVD.

Page 3: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

CENTUM VP Software Installation Flow

Start the installation

Installation ofWindows OS

Installation of Windows Security patch

Complete the installation

Setting of Windows(Display and UPS, etc.)

Installation of CENTUM VP Software

Setting/Installing of Network(Vnet and Ethernet, etc.)

Setting after the installation(Creation of account, UPS etc.)

Installation of USB driver for OPKB

Setting IT security

The part of gray boxes are in the scope of this document

Log on as an Administrator User

Please uninstall VP after the training

Page 4: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Required Hardware/Software for VP

Item CENTUM VP R4.01 HISOS Windows Vista Business Edition SP1

Windows XP Professional SP2Windows Server 2003 SP2Windows Server 2003 R2 SP2

32bit OSSP2 or later SP2

CPU Intel Core Duo 2.13GHzXeon Dual Core 2.0GHz In case of [XP, 2003 Server]:(Normal PC) Intel Pentium4 2.8GHz(Industrial PC) Intel Pentium-M 1.6GHz

More than 2GBIn case of [XP, 2003 Server]:More than 1GB

Graphic memory: Min 128MBDirectX9 with WDDM driver

Be careful if a VP upgrading potential customer wants to keep existing PC (HIS) as it is.

Memory In case of XP or 2003 Server, memory is not so critical.

Graphic Board

Page 5: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Required Hardware/Software for VP

Item CENTUM VP R4.01 HISHDD More than 40GB

(Space Disk: more than 20GB)

Drive DVD-ROM drive, FD drive

-SXGA(more than 1280*1024 more, True color)

-WXGS (option)(more than 1440*900 more, True color)

MouseControl Bus Card: VF701/VI701Ethernet port

VP System S/W shall be provided in DVD

Display

Others

Page 6: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Software Operating Environment

CENTUM VP uses the following software:

Support target OS– Windows XP Professional SP2– Windows Vista Business Edition SP1– Windows 2003 Server SP2– Windows 2003 Server R2 SP2

Page 7: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

CENTUM VP Software Installation Flow

Start the installation

Start the installation

Installation ofWindows service pack

Installation of Windows Security patch

Complete the installation

Setting of Windows(Display and UPS, etc.)

Installation of CENTUM VP Software

Setting of Network(Vnet and Ethernet, etc.)

Setting after the installation(Creation of account, UPS etc.)

Installation of USB driver for OPKB

Setting IT security

The part of gray boxes are in the scope of this document

Login as Administrator

Page 8: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting of Windows

1. File System1.1 Click My computer and then select the Property of

“C “drive for example , and confirm the file system is NTFS.

2. Setting of Virtual Memory

2.1 Select Start menu -> “Control Panel” -> “System”

2.2 Select “Advanced” tab.

2.3 Press “Settings” button on Performance.

Page 9: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting of Windows

2.4 Select “Advanced” tab.

2.5 Select “Change” button on Virtual memory.

2.4

2.5

2.6 Set up the recommended sizethat is equivalent to 3 times of main memory to "Initial size (MB)" and "Maxim size (MB)" in "pagingfile size for each drive".

2.6

2.7 Click “OK “button

Page 10: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting of Windows

3. Setting of System Property

3.1 Select “Visual Effects” tab3.2 Select “Adjust for best

performance”

3.3 Click “OK “button

Page 11: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting of Windows (OP for this training)

4. Property of Panel

4.1 Select Start menu -> “Control Panel” -> “Display”

4.2 select the "Desktop" tab and set "(None)" for "Background

4.3 Open the "Screen Saver" tab and set "(None)” for "Screen Saver".

4.4 Open "Settings" tab and set "Medium (16 bit)" for "Color quality".

OP

Page 12: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting of Windows

5. Setting of Power Options

5.1 Open the Property of the system Select Start menu -> “Control Panel”-> “ Power Options ”

“Power Schemes ” tab“ Turn off monitor " -> Never“ Turn off hard disks " -> Never “ System standby " -> Never“ System hibernates " -> Never

5.2 In the “Advanced ”tab" Power button on my computer" -> "Do nothing"

5.3 In the “ Hibernate ”tab"Enable hibernation" -> Do not check.

OP

Page 13: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

CENTUM VP Software Installation Flow

Start the installation

Start the installation

Installation ofWindows service pack

Installation of Windows Security patch

Complete the installation

Setting of Windows(Display and UPS, etc.)

Installation of CENTUM VP Software

Setting of Network(Vnet and Ethernet, etc.)

Setting after the installation(Creation of account, UPS etc.)

Installation of USB driver for OPKB

Setting IT security

The part of gray boxes are in the scope of this document

OP

Page 14: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

CENTUM VP Software Installation Flow

Start the installation

Start the installation

Installation ofWindows service pack

Installation of Windows Security patch

Complete the installation

Setting of Windows(Display and UPS, etc.)

Installation of CENTUM VP Software

Setting of Network(Vnet and Ethernet, etc.)

Setting after the installation(Creation of account, UPS etc.)

Installation of USB driver for OPKB

Setting IT security

The part of gray boxes are in the scope of this document

OP

Page 15: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

CENTUM VP Software Installation Flow

Start the installation

Start the installation

Installation ofWindows service pack

Installation of Windows Security patch

Complete the installation

Setting of Windows(Display and UPS, etc.)

Installation of CENTUM VP Software

Setting of Network(Vnet and Ethernet, etc.)

Setting after the installation(Creation of account, UPS etc.)

Installation of USB driver for OPKB

Setting IT security

The part of gray boxes are in the scope of this document

Page 16: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

CENTUM VP Software Installation Type

1. New InstallationThe New Installation is an installation that is newly executed to a PC in which CENTUM VP Software has not been installed. The keycode is required for the installation.

2.Version Up Installation CS3000 ---> CENTUM VPIn the Version Up Installation, the CENTUM VP Software is installed in PC in which CS3000 Software has already beeninstalled.

The keycode of CENTUM VP is required for the installation.

3. Revision Up InstallationIn the Revision Up Installation, the revision improvement of PC in which CENTUM VP has already been installed is executed. The keycode is not required when there is no additional package.

4.Re-InstallationIn the Re-Installation, the Software of the same revision is installed for repair purpose or etc. in PC in which theCENTUM VP has already been installed. The keycode of CENTUM VP is not required.

5.Add InstallationThe Add Installation is an installation that is executed for package adding purpose in PC in which the CENTUMVP has already been installed. The Software Medium of the same revision as the keycode of additional packageis required

Page 17: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

Stat the Version UpInstallation

Version Up processing of CS3000 project database

Installation of CENTUM VP Software

Update of device driver

Restoration of Package Data

Backup ofPackage Data

Release of HIS automatic activation and CENTUM Desktop

Complete the Version UpInstallation

OP

Page 18: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Backup and Restoration of Package DataPackage Name Data to back up/restore

LHS1100LHM1101

Operation and Monitoring Basic Function It keeps the HIS setup information. Optionally, back up or restore the following definition. ・Trend/historical data・Set up information of HIS utility・Voice Message definition and Media Data・Context Menu definition

LHS1150 Remote Operation and Monitoring Server function Package The same as LHS1100

LHS4200 Consolidated Historical Message Viewer The Data stored in the Historical integrated server can be inherited. It requires to re-configure the storage location in each HIS.

LHS4700 Advanced Alarm Filter Package Export and Import of Alarm Filter definition are required.

LHS4800 Consolidated Alarm Management System (CAMS for HIS)

Optionally, back up/restore the following file.・CAMS configuration information

LHS6510 Long-Term Data Archive Package Inheritable by the Backup/Restore the long-term Data.

LHS6530 Report Package Inheritable by the Backup/Restore of Report definition file

LHS6600LHM6600

CS Batch 3000 Process management package No obvious referenceThe control recipe is not inherited.

LHS6710LHM6710

FCS Data setting/Acquisition Package (PICOT) Back up List of the definition Data is required.

LHS5100LHM5100

Builder basic function Back up/Restore the project database.

LHS5110 Access Control Package Re-configuration in the Access Control utility is required.(The definition is SVA so that the user can store/restore.)

LHS5150 Graphic builder The project database is inherited. (Back up the SVA file by the User)

LHS5160 CS Batch 3000 builder Back up/Restore the project database.

LHS5161 CS Batch 3000 Recipe management package Back up/Restore the recipe database.

LHS5170 FDA:21CFRpart11 support package Back up/Restore the database that was saved by FDA support.

LHS5030 C Language Development Environment Package for FCS Back up/Restore the files that were created by the User.

LFS1250 Generic Subsystem Gateway Package Back up/Restore the OPC server definition information and the Item definition information file.

LPC6900 SOE Server Backup/Restore the database of SOE server.

LPC6920 SOE Viewer Backup the configuration files.

OP

Page 19: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Data to back up while operating CS3000

1.Backup and Restoration of long-term storage DataBack up the storage Data by using the archive function of Long-Term Data Archive Package.At this time, also back up the following file and return it to the same location after changing into CENTUM VP.\\<computer name>\LTDATA\LOG\BKHLogFile.txtIt can be referred as a Retrieve Data after the version up to the CENTUM VP.

2.Backup of Report definitionCopy the definition in each Report to other Medium by using the copy function of the Report Package.

3.Backup of Advanced Alarm Filter definitionBack up the filter definition by using the export function of Alarm Filter definition.

OP

Page 20: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Data to back up while it is in an off-line state1. Database related to HIS

Backup the HIS related files such as "Voice message", "Trend", "Recipe/Control recipe" and so on.

<CS3000 installation folder>\his\database : Voice messages, etc.<CS3000 installation folder>\his\recipe : Recipes and Control

recipes<CS3000 installation folder>\his\save : Long-term, Closed data,

Scheduler, etc.<CS3000 installation folder>\his\Trend : Trend data<CS3000 installation folder>\his\spconf : Right click menu, etc.<CS3000 installation folder>\his\Media\User : Media data

The tokuchu files are located in the following folder. Please confirm to tokuchu responsible department whether tokuchu program can use these restored files after installation.

<CS3000 installation folder>\his\spconf<CS3000 installation folder>\his\user

OP

Page 21: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Data to back up while it is in an off-line state2. Backup and Restore for CAMS for HIS

Set CAMS to invalid before backup CAMS data.Backup all files located in the following folder.CAMS folder: <CS3000 installation folder>\CAMS

If CAMS historical data is not necessary, files in the following folder are unnecessary.CAMS historical data folder: <CS3000 installation folder>\CAMS\hist

Restore CAMS data before setting CAMS to enable.Copy all backuped files to <CENTUM VP installation filder>.

OP

Page 22: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Data to back up while it is in an off-line state3. When using the Access Control function, FDA function

When the “engineers' account files for referencing” specified by the Access Control utility is placed under the CS3000 installation folder, back up the files under the folder.

At that time, make a file called “EngPassword2.odc” writable. Restore the file after the installation of CENTUM VP, and reconfigure by the Access Control utility

4. FCS Data setting / Data of PICOT Acquisition Package

Back up the definition file in the following folder of this Package.<CS3000 installation folder>\his\users\save\BKUPICOT

After the installation of CENTUM VP, restore the backed up files to the following folder. <CENTUM VP installation folder>\his\users\save\BKUPICOT

OP

Page 23: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Data to back up while it is in an off-line state

5. Data of Generic Subsystem Gateway Package

Back up the definition file in the following folder of GSGW, and restore it after the Version Up.

OPC server definition information file: <CS3000 installation folder>\apcs\GPLS\BKEOPCSVRDef.csv

Item definition information file:<CS3000 installation folder>\apcs\GPLS\BKEOPCITEMDef.csv

After the installation finished,restore these back up datato the appropriated location

OP

Page 24: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

Stat the Version UpInstallation

Version Up processing of CS3000 project database

Installation of CENTUM VP Software

Update of device driver

Restoration of Package Data

Backup ofPackage Data

Release of HIS automatic activation and CENTUM Desktop

Complete the Version UpInstallation

Page 25: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Release of HIS automatic activation and CENTUM Desktop

Do not Check

WindowsStandard

Select Start menu Program YOKOGAWA CENTUM HIS Utility

Page 26: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

Stat the Version UpInstallation

Version Up processing of CS3000 project database

Installation of CENTUM VP Software

Update of device driver

Restoration of Package Data

Backup ofPackage Data

Release of HIS automatic activation and CENTUM Desktop

Complete the Version UpInstallation

OP

Page 27: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Update of Device Driver

Installation Control Bus Driver USB driver for OPKB

OP

Page 28: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

Stat the Version UpInstallation

Version Up processing of CS3000 project database

Installation of CENTUM VP Software

Update of device driver

Restoration of Package Data

Backup ofPackage Data

Release of HIS automatic activation and CENTUM Desktop

Complete the Version UpInstallation

Page 29: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

1. Log-on as an Administrator User2. Terminate all of running applications3. Set up the Software Medium of CENTUM VP to the DVD ROM

drive. 4. Click “CENTUM VP Software” button to start the installation

of the CENTUM VP Software5. Following window comes up

Page 30: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

6. CENTUM VP requires the following software..Net Framework 3.0MSXML 6.0 SP1When the above software has not been installed in , following window popped up.

7. Without setting the keycode FDC to the Floppy diskdrive, the following dialog is displayed.

Sample

Ensure ONLY Keycode FDC/USB drive is inserted

Page 31: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

8. Specify the folder path in which the keycode file exists.

9. “Welcome to the Install Shield Wizard for YOKOGAWA CENTUM VP”dialog is displayed.

Click “Next“ Button

This training keycode file should be located under “C” drive directly.

Page 32: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

10.

11.

The dialog to input the install destination folder is displayed.

Click “Next“ Button

Enter your name and Company Name information and Click “Next” button

Page 33: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

12.

13.

14.

The dialog to input ID numberis displayed.

Click “Next“ Button

Click “No” button

Click “Next” button

Page 34: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

15.

16.

Click “Next“ Button

Enter your HIS station name

Page 35: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

17.

18.

The dialog to confirm the description of the installation settings is displayed.Click Next to follow the instruction displayed on the screen.

Installation of VP will start.

Page 36: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

19. Choose “Yes”, and press “Finish”to exit the installation

VP installation is finished

Please uninstall VP after the training

Page 37: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

Stat the Version UpInstallation

Version Up processing of CS3000 project database

Installation of CENTUM VP Software

Update of device driver

Restoration of Package Data

Backup ofPackage Data

Release of HIS automatic activation and CENTUM Desktop

Complete the Version UpInstallation

Page 38: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Version Up processing of CS3000 project database

1.The name of TOP folder in which old CS3000 has been installed is changed to the name with “_bak”

2. After the installation of CENTUM VP, CENTUMVP folder is generated.

3. Please moved the project database prepared by ETC to the following location. (install folder)\CENTUMVP\eng\bkproject\VP_PJT

Page 39: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Version Up processing of CS3000 project database3. Go through

“All programs” in the start menu -> “YOKOGAWA CENTUM”, and activate “Project's Attribution Utility”Register the project as ”Default Project” into the project list.

4. Go through “All programs” in the start menu -> “YOKOGAWA CENTUM”, and activate “System View”.Revise project information window comes.

5. After the data base has been converted to R4.01 version , below guideline window appears. This window appears when CS3000 HIS has registered.

OP

OP

Page 40: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Version Up processing of CS3000 project database

5. Click OK

<About Conversion>

All HIS database can be converted by usingHIS Database Conversion Tool from Tools menu / HIS Database Conversion Tool

CS3000 graphic file can be converted to VP Graphic file by using Graphic File Converter tool , which launch fromYOKOGAWA CENTUM / Graphic File Converter

OP

OP

6. Start “System View” from Start menu.Confirm if the CENTUM VP is installed well.After confirmation, please close “System View”.

Page 41: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Installation Procedure CS3000 ---> CENTUM VP

Stat the Version UpInstallation

Version Up processing of CS3000 project database

Installation of CENTUM VP Software

Update of device driver

Restoration of Package Data

Backup ofPackage Data

Release of HIS automatic activation and CENTUM Desktop

Complete the Version UpInstallation

OP

Page 42: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Restoration of Package Data

Restore the Data of each Package that is Backed up of Package Data

OP

Page 43: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

CENTUM VP Software Installation Flow

Start the installation

Start the installation

Installation ofWindows service pack

Installation of Windows Security patch

Complete the installation

Setting of Windows(Display and UPS, etc.)

Installation of CENTUM VP Software

Setting of Network(Vnet and Ethernet, etc.)

Setting after the installation(Creation of account, UPS etc.)

Installation of USB driver for OPKB

Setting IT security

The part of gray boxes are in the scope of this document

Page 44: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security

The Setting IT Security utility is started by clicking “Setting IT Security” in the CENTUM VP installer menu.

Page 45: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security

1.Select the security type appropriate to the IT operation mode,and click "Next" button.

Select this when configuring IT Security in each PC without using the Windows domain controller. The user account will be managed in each PC.

Select this when managing the user and group of the account by the Windows domain controller. It is necessary to create the group and user account by the domain controller before conducting this Setting Security.

Set the Access permission of shared file or the Connection setup of DCOM to the same Security level as the CS3000 or earlier version. Windows Firewall becomes invalid. Apply this Setting Security when connecting to other systems such as PRM, ProSafe-RS with no Security, or PC component of old revision CS3000.

In this training,select this item

Page 46: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security2. All security setting items are to set to this security setting utility3. After setting, progress bar appears

4. Following window comes if the CENTUM account had existed.

5. The following dialog appears. Click "OK" button and reboot the PC.

This is the end of the Setting IT Security.

Page 47: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

CENTUM VP Software Installation Flow

Start the installation

Start the installation

Installation ofWindows service pack

Installation of Windows Security patch

Complete the installation

Setting of Windows(Display and UPS, etc.)

Installation of CENTUM VP Software

Setting of Network(Vnet and Ethernet, etc.)

Setting after the installation(Creation of account, UPS etc.)

Installation of USB driver for OPKB

Setting IT security

The part of gray boxes are in the scope of this document

Page 48: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting after the installation

1. Setting of Windows- Creation of User Account- Setting of Windows Operating Environment- Procedure of adding SQL server account in the SOE Package

2. Setting of UPS (uninterruptible power supply) - Command for UPS Management of CENTUM VP

3. Setting of the package specific

For more specific information , please refer to the Installation Manual.

OP

Page 49: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

When the Security type is the Windows domain environment, the user account is to be created by the Windows domain controller. If necessary, by the Windows domain controller, create a user such as the one with the Operation and Monitoring authority, the one with the Engineering privilege, or the one with the privilege of OPC connection.

OP

Page 50: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

1) Log on to Windows with administrator's privilege.2) Right click “My Computer”, then choose “Manage”

from the menu. “Computer Management” window displays.3) Choose “Local Users and Groups” displayed in the left pane,

then open the “Users” folder and select a “New user” on right click menu.

Setting IT Security - Creation of user account -

1. The user account is to be created on each local PC.

Page 51: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

Enter user name and their passwordto create new user

And also PW neverexpires.

User information for trainingfor Operator

User names: OPE01 Password : 012008Ope

for EngineerUser name : ENG01 Password : 012008Eng

for Engineering administratorUser names : ENGAD01 Password : 012008Engad

for MaintenanceUser names : MNT01 Password : 012008Mnt

Page 52: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

User information for trainingfor Operator

User names: OPE01 Password : 012008Ope

for EngineerUser name : ENG01 Password : 012008Eng

for Engineering administratorUser names : ENGAD01 Password : 012008Engad

for MaintenanceUser names : MNT01 Password : 012008Mnt

Page 53: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

User information for trainingfor Operator

User names: OPE01 Password : 012008Ope

for EngineerUser name : ENG01 Password : 012008Eng

for Engineering administratorUser names : ENGAD01 Password : 012008Engad

for MaintenanceUser names : MNT01 Password : 012008Mnt

Page 54: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

User information for trainingfor Operator

User names: OPE01 Password : 012008Ope

for EngineerUser name : ENG01 Password : 012008Eng

for Engineering administratorUser names : ENGAD01 Password : 012008Engad

for MaintenanceUser names : MNT01 Password : 012008Mnt

Page 55: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

2. Double Click “OPE01" user and select "Member Of" tab

3. Select Users and Click “Add” button.

User Group for trainingOPE01 : CTM_OPERATORENG01 : CTM_ENGINEER

ENGAD01 : CTM_ENGINEER_ADMAdministrator

MNT01 : CTM_MAINTENACEAdministrator

Page 56: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

4.Select “Advanced” tab

5.Click “Find Now”

Page 57: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

6. Select “CTM_OPERATOR “ for users group

Page 58: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

7. Select other three user groups which the newly-added user for ENG01, ENGAD01 and MNT01 to belong.

User Group for trainingOPE01 : CTM_OPERATORENG01 : CTM_ENGINEERENGAD01 : CTM_ENGINEER_ADMMNT01 : CTM_MAINTENACE

This is the end of the Setting after the installation

Page 59: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Setting IT Security - Creation of user account -

An account name of “CENTUM” is automatically created, and the password has been set to “Yokogawa1” by the default.Select the password of “CENTUM” account for “Password never expires”.Because the download to HIS, Sequence table, or status display of SFC will not operate properly if the password is expired.

1. Log on to Windows with administrator's privilege.

2. Right click “My Computer”, then choose “Manage”from the menu. “Computer Management” window displays.

3. Choose “Local Users and Groups” displayed in the left pane, then open the “Users” folder and select a user.

4. Select “Password never expires” and click “OK”.

OP

Page 60: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Uninstallation of CENTUM VP

1.The Uninstallation of CETUM VP Software can be conductedfrom “Add or Remove Programs”. Select “Remove”

2. To manually delete the files which were not deleted by the Uninstallation operation, delete all files placed by using explorer.

- Program file%SystemDrive%\Program Files\YOKOGAWA

- The application data(For Vista): %SystemDrive%\Program Data\Yokogawa(For XP): %SystemDrive%\Documents and Settings\All Users\Application Data\Yokogawa

- CENTUM VP project data base etc.CENTUM VP installation folder e.g. C:\CENTUMVP

OP

Page 61: centum VP Installation guide

Yokogawa Global Engineering Center Rev.0Copyright © Yokogawa Electric CorporationJuly 1st, 2008

Our commitment Your future

Thank you for your attention