Upload
buiphuc
View
214
Download
0
Embed Size (px)
Citation preview
For Training Purposes OnlySept 04
6-i
P I L O T T R A I N I N G G U I D E
ELECTRICAL
Chapter 6: Electrical
TABLE OF CONTENTS
Page
Introduction .........................................................................................................................6-1Variable Frequency Power Generation System............................................................6-1General .........................................................................................................................6-1
EPGDS Components ..............................................................................................6-3EPGDS Architecture ...............................................................................................6-4
AC System ....................................................................................................................6-5Emergency AC Power...................................................................................................6-6
AC System Distribution ...........................................................................................6-7Electrical Panel .......................................................................................................6-8Electrical Management System...............................................................................6-9AC System EICAS Messages ...............................................................................6-12AC System Synoptic .............................................................................................6-14AC Bus Feed System............................................................................................6-15AC Bus 1 ...............................................................................................................6-16AC Bus 2 ...............................................................................................................6-17AC Bus 3 ...............................................................................................................6-18AC Bus 4 ...............................................................................................................6-19AC ESS Bus..........................................................................................................6-20EXT AC Power ......................................................................................................6-21
DC System..................................................................................................................6-22DC System Distribution .........................................................................................6-23Electrical Panel .....................................................................................................6-24DC System EICAS Messages...............................................................................6-25DC System Synoptic .............................................................................................6-27DC Bus Feed System............................................................................................6-28DC Bus 1...............................................................................................................6-29DC ESS Bus..........................................................................................................6-30BATT Bus..............................................................................................................6-31DC Bus 2...............................................................................................................6-32External DC Power................................................................................................6-33RAT GEN Feed .....................................................................................................6-34Emergency DC Power...........................................................................................6-35DC Power Emergency Override............................................................................6-36EICAS Philosophy.................................................................................................6-37
EMS Circuit Protection ................................................................................................6-38Cockpit Circuit Breaker Panel (CCBP)..................................................................6-38EMS CDU..............................................................................................................6-39SYSTEM Key ........................................................................................................6-39ELEC SYSTEM Key..............................................................................................6-40BUS Key................................................................................................................6-41AC Bus 2 ...............................................................................................................6-42AC Bus 3 ...............................................................................................................6-43
6-ii For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC Bus 4 ............................................................................................................... 6-44AC ESS Bus.......................................................................................................... 6-45DC EMER Bus ...................................................................................................... 6-46DC Bus 1............................................................................................................... 6-47DC Bus 2............................................................................................................... 6-54DC ESS Bus.......................................................................................................... 6-61BATT Bus.............................................................................................................. 6-67AV BATT Bus ........................................................................................................ 6-74APU BATT Bus ..................................................................................................... 6-75CNTL Key.............................................................................................................. 6-76TEST Key.............................................................................................................. 6-77Fire Test ................................................................................................................ 6-78Stall Test ............................................................................................................... 6-79Aural Warning Test ............................................................................................... 6-80Lamp Test ............................................................................................................. 6-81EMER CNTL ......................................................................................................... 6-82
System Integration ............................................................................................................ 6-83
For Training Purposes OnlySept 04
6-1
P I L O T T R A I N I N G G U I D E
ELECTRICAL
INTRODUCTION
VARIABLE FREQUENCY POWER GENERATION SYSTEMThe Global Express utilizes an AC power generation system based on Variable Frequency Generators (VFG). The use of variable frequency power engenders several advantages including:
• An increased efficiency of 80% compared with fixed frequency systems where efficiency is in the order of 65%
• Ease of voltage conversion• Reduction in system weight due to lighter alternator and distribution cables; and• Increased reliability due in large part to the eradication of Integrated Drive
Generators (IDGs)
GENERALThe airplane AC electrical power generation and distribution system (EPGDS) consists of four 40 kVA, engine-driven, variable frequency generators (VFG), and one constant frequency 40 kVA APU generator. Control and protection of the generators is provided by five identical generator control units (GCU). Distribution systems furnish power to the following buses, through the AC power center (ACPC) and the cockpit circuit breaker panel (CCBP).
• AC bus 1, 2, 3, 4 (ACPC)• AC bus 1A, 2A, 3A, essential (CCBP)
A ram air turbine (RAT), deployable during flight, supplies 115-volt, 400-Hz, 3-phase AC power 9 kVA for emergency use (when all other AC sources have been lost) to supply AC power to the AC essential bus. Mounted on the RAT is a hydraulic pump which powers hydraulic system No. 3.
For other load devices requiring DC power, 115-volt AC power is converted to 28-volt DC power by four 150 Amp transformer-rectifier units (TRU). 28-volt DC power is distributed through the DC power center (DCPC) and the secondary power distribution assemblies (SPDA) onto the following buses:
• DC bus 1 and 2• DC essential bus• Battery bus• DC emergency bus
The 25-ampere-hour, 24-volt DC avionics battery provides power to the following:
• Stored energy to selected electronic equipment during normal ground operations• During flight in an emergency (loss of all generators) to the flight essential DC
loads
6-2 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
The 42 ampere-hour, 25.2 volt DC APU battery provides power to the following:
• Stored energy for starting the APU during both ground and flight operations• During flight in an emergency (loss of all generators) to the flight essential DC
loads
The following buses are connected directly to their respective battery terminals:
• Avionics battery direct bus• APU battery direct bus
Battery chargers and battery heaters, powered by the main AC buses, maintain the main and APU batteries in a charged and warm condition.
An Electrical Control Panel, located in the cockpit, provides control of all generators, external AC and DC power and battery master.
An Electrical Management System (EMS), located in the cockpit, controls and displays the status of circuit breaker, on the two control display units (CDU).
External AC power, supplied through the AC receptacle, situated on the aft left side of the airplane, (on the fairing at the root of the wing trailing edge), provides power to:
• AC bus 1, 2, 3, 4• AC 1A, 2A, 3A and essential bus
External DC power, supplied through the DC receptacle, situated on the aft underside of the fuselage, provides power to the APU battery direct bus.
The APU can be started using external DC power, however, a serviceable avionics battery is required.
The airplane batteries cannot be charged through external DC power, since the APU BATT charger and the avionics BATT charger are powered by AC bus 2 and 3 respectively.
For Training Purposes OnlySept 04
6-3
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EPGDS COMPONENTS
GX
_0
6_
00
1
TRUs
AvionicsBattery
APU Batteryand Battery
Charger
APUGenerator
APU StartContactorAssembly
DC PowerReceptacle
DC PowerCenter
AC PowerCenter
AC PowerReceptacle
Cockpit CircuitBreaker Panel
SecondaryPower Distribution
Assemblies
GeneratorControlUnits
ControlDisplayUnits
LH EngineVF Generators
RH EngineVF Generators
Ram AirTurbine
ControlPanel External
ServicePanelBattery
Charger
6-4 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EPGDS ARCHITECTURE
TRU 1 ESSTRU 1
ESSTRU 2
TRU 2
APUSTARTMOTOR
DC EXTPOWER
AC EXTPOWER
AC POWER CENTER
DC POWER CENTER
ELECTRICALCONTROL
PANEL
LH Engine RH Engine
GEN1
GEN2
GEN4
GEN GENGCU GCU GCU GCU GCU GCURAT
115/200 V, 3 PHASE, 324-596 Hz
28 V, DC
CONTROL, PROTECTION, COMMUNICATIONS
APU
GX
_0
6_
00
2
EXT PWRCONTROL
PANEL
SPDA 1 SPDA 2 SPDA 3 SPDA 4
AVIONICSBATTERY
AVIONICSBATTERYCHARGER
APUBATTERYCHARGER
GEN3
COCKPIT CIRCUIT BREAKER PANEL
APUBATTERY
APUSTART CONTROL
ASSEMBLY (ASCA)
EMSCDU 1
EMSCDU 2
For Training Purposes OnlySept 04
6-5
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC SYSTEMAC power is normally supplied by four variable frequency generators (VFG), two on each engine, rated at 115 volt, 40 kVA, 3-phase, 324-596 Hz output.
The generators are brushless, oil cooled and are a three stage machine type generator. The first machine is a permanent magnet generator (PMG), generator excitation function, which provides output power. The second machine, is the main exciter which receives its field excitation through the generator control unit (GCU).The GCU will remove the generator from its bus and de-energize the generator, in the event of malfunction. The third machine, is the main alternator, which incorporates current transformers that are used for feeder fault and overcurrent protection.
All VFG output is routed through the AC power center (ACPC), which protects, controls and distributes primary AC power to the main airplane buses. VFG output is then routed through the CCBP to bus feeders 1A, 2A and 3A and the AC ESS BUS for power distribution to the 4 transformer rectifier units (TRU). Each generator normally powers its own bus, through a generator line contactor (GLC). In the event of a generator malfunction, the generator transfer contactors (GTC), will automatically switch to an alternate generator, to supply the affected bus. AC bus 2 and 3 are automatically shed during single generator operations and AC bus 1 and 4 are priority.
AC power can also be supplied by the auxiliary power unit (APU) generator. The APU constant frequency generator, rated at 115 volt, 40 kVA, 3-phase, 400 Hz output.
External AC power, 115 volt, 3-phase, can also be used to supply power to the AC system.
BATTERYMASTER
GROUNDSERVICE
EXT AC EXT DC
BATTON
ONAVAIL
IN USE
AVAIL
IN USE
MIC HDPHLAMPTEST
APUSHUT-OFF
GX
_06_003
External AC/DC Power StatusIndicatorsDisplays status of external AC orDC power.
Ground Service Mode SwitchEnables maintenance personnel to power selected ACloads in the cabin, when AC external power is available.
Battery Master Status IndicatorDisplays status of the battery masterswitch (EMS or ON position).
External AC PowerReceptacle
6-6 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EMERGENCY AC POWEREmergency AC power is supplied by the ram air turbine (RAT) in flight, rated at 115 volts, 9 kVA, 3-phase. With engines running, the RAT will deploy with a 14-second time delay following the loss of all AC power, if the slat/flap handle is at the in/zero position. It will deploy automatically if the slat/flap handle is not at the in/zero position. With a dual-engine failure, the RAT will deploy automatically, regardless of slat/flap handle position. The RAT can also be manually deployed by pulling RAT manual deploy handle, located on the center pedestal. Once deployed, the RAT will power the AC ESS BUS via the ram air turbine line contactor (RATLC).
The RAT also incorporates a hydraulic pump, which powers hydraulic system No. 3. At approximately 147 KIAS and below, the RAT sheds its electrical output, giving priority to hydraulics. A ground safety pin is installed in the nosewheel well area to secure the RAT in position while on ground.
RATManual DeployHandle
GX
_0
6_
00
4
GX
_06_005
DeploymentActuator
RetractionPump
Uplock
Ram AirTurbine
Hydraulic Pump
Generator
GroundSafetyPin
DownlockRelease
For Training Purposes OnlySept 04
6-7
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC SYSTEM DISTRIBUTION
GX
_0
6_
00
6
GEN 1
GEN 2
GEN 3
GEN 4
GTC 9
GTC 8
GTC 10 GTC 2
GTC 12
GTC 11
GTC 1GTC 7
K2
K3
K4
K6
EPLC APULC
K1 K8
K11
GLC 1 GLC 2
GLC 3
GLC 4
GTC 5 GTC 4
GTC 6 GTC 3
K5 K7
K10
K9
K13
K12
K14
K15
K17
K20
K18
K21
K22
K24
K16
K19
K23
K25
K26
CBA14
CBA20
CBB7
CBA8
CBA2
CBA1
RATLCK3
ACMP3B
CABINFEEDS
C/BLOADS
C/BLOADS
APU BATTCHGR
APUBATTHTR
SSPCLOADS
SSPCLOADS
SSPCLOADS
SSPCLOADSCABIN
FEEDS
CABINFEEDS
CABINFEEDSACMP
2BC/B
LOADSC/B
LOADSACMP1B
ACMP3A
AC BUS 1
AC BUS 1A
AC BUS 2
AC BUS 2A
AC BUS 3
AC BUS 3A
AC BUS 4
CCBP
ACPC
GEN 1 GEN 3GEN 2 GEN 4
EXTAC
APUGEN
ENG 2ENG 1
RATGEN
EXT AC
APU GEN
RAT GEN
AC ESS BUS
6-8 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
ELECTRICAL PANELThe generators and external power can be controlled manually, by selecting the appropriate switch on the electrical panel, located on the overhead panel. GEN 1, 2, 3, 4 and APU GEN switches are normally ON.
NOTEIf RAT GEN is powering AC ESS BUS, and a main generator is available, stow the RAT deploy handle and select RAT GEN to OFF, to transfer AC ESS BUS to the main generator. The RAT GEN will remain armed to ensure RAT GEN priority in the event of loss of all main generators.
ELECTRICALEXT AC
AVAIL
ON
FAIL
OFF
GEN 1
FAIL
OFF
EXT DC
AVAIL
ON
GEN 3 GEN 4
FAIL
OFF
GEN 2
FAIL
OFF
PUSH OFF/RESET
PUSHOFF/RESET
APU GEN
FAIL
OFF
RAT GEN
ON
OFF
BATT MASTER
EMS
OFF
ON
ASTE
E
OF
External AC Switch
AVAIL Light
ON Light
Displays status of AC external power• - Comes on to indicate thatexternal AC power is connected and is thecorrect phase, voltage and frequency.• - Indicates that external poweris being used or can be used by theairplane power distribution system tomaintain power to the AC buses.
GEN 1, 2, 3, 4 Switches
FAIL Light
OFF Light
Used to reset or to turnapplicable generator off.• - Indicates a failedgenerating channel (GEN, GCU,GLC) / FAIL Light illuminateswhen fire discharge handle ispulled.• - Indicatesgenerator operation inhibited.
RAT GEN Switch
ON Light
OFF Light
Used to reset a fault or to turn RATgenerator off.• - Indicates that RATgenerator is on line.• - Indicates that RATgenerator operation is inhibited.
APU GEN Switch
FAIL LightOFF Light
Used to reset or to turn APU generator off.• - Indicates a failed generating channel.• - Indicates generator operationinhibited.
GX
_0
6_
00
7
For Training Purposes OnlySept 04
6-9
P I L O T T R A I N I N G G U I D E
ELECTRICAL
ELECTRICAL MANAGEMENT SYSTEMLoad control consists of smart contactors, Solid State Power Controllers (SSPC) and control logic. Smart contactors and SSPC are functionally similar to a switch in series with a circuit breaker. The status of all circuit breakers is monitored (trips are automatically displayed) and can be acknowledged and reset via the Electrical Management System (EMS). EMS Control Display Units (CDU) are installed on the pilot’s and copilot’s side panel.
M
M
STANDBY
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
LINE SELECT KeysUsed to selectdisplayed items.
Page TitleDisplayed when aselection has beenmade using pageselect key.
Page NumberDisplays which page isselected and how many pagesare available.
Activation KeysUsed to switchcurrent status andselect display items.
STATUS KeyDisplays the statusof tripped, out andlocked circuitbreakers. System Key
Displays circuitbreaker status byaircraft system.
BUS KeyDisplays circuitbreaker status byelectrical buses.
PREVIOUS PAGEKeyScrolls list toprevious page.
NEXT PAGE keyScrolls list to nextpage.
TEST KeyDisplays system'stest options.
CNTL KeyDisplays system'scontrol options. EMER CONT
KeyDisplays busisolation status.
NOTE:If no action is taken within 45to 60 secs of page activation orselection, the display will revertback to STBY page.
GX
_0
6_
00
8
BRIGHTNESSControl
CIRCUIT BREAKER - SYSTEM
DOORS
ELECAIR COND/PRESS
AFCS
ENGINE
FIRE
FLT CONTROLS
APU
BLEED
CAIMS
COMM FUEL
1/2
6-10 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
The circuit breaker STATUS page will automatically appear, anytime a circuit breaker trips, if the screen is blank and has been blank for 2 seconds, (CB TRIP message appears on EICAS) or can be selected using STAT page select key.
M
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
FUEL COMPUTR CH B
DU 1
RAD ALT 1
AC1
AC ESS
DC ESS
DC ESS
DC 1
LOCKED
OUT
OUT
LOCKED
TRIP
ACPC
CCBP
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
FUEL COMPUTR CH B
DU 1
RAD ALT 1
AC1
AC ESS
DC ESS
DC ESS
DC 1
LOCKED
OUT
OUT
LOCKED
TRIP
ACPC
CCBP
GX
_0
6_
00
9
FUEL COMP BCircuit breakeridentification
DC 1BUS location ofaffected circuitbreaker.
ACPCThermal circuit breakerlocated on the component withinACPC.
LOCKEDCircuit breaker hasbeen locked bymaintenance personnel.
OUTCircuit breaker hasbeen selected out.
TRIPCircuit breakerhas tripped.
CCBPThermal circuit breakerlocated on Cockpit CircuitBreaker Panel.
NOTE: Thermal circuit breakers cannot be reset via the EMS CDU.
For Training Purposes OnlySept 04
6-11
P I L O T T R A I N I N G G U I D E
ELECTRICAL
Circuit breakers can be acknowledged, or acknowledged and reset, using the line select keys.
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
FUEL COMPUTR CH B
DU 1
RAD ALT 1
STAB TRIM 2
AC1
DC ESS
DC ESS
DC 1
AC ESS
LOCKED
IN
LOCKED
TRIP
OUT
ACPC
CCBP
THERM CB CAN’T BE CHANGED FROM CDU
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
DU 1
RAD ALT 1
FUEL COMPUTR CH B
AC1
AC ESS
DC ESS
DC 1
DC ESS
LOCKED
OUT
LOCKED
TRIP
OUT
ACPC
CCBP
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
DU 1
RAD ALT 1
FUEL COMPUTR CH B
AC1
AC ESS
DC ESS
DC 1
DC ESS
LOCKED
OUT
LOCKED
TRIP
OUT
ACPC
CCBP
NOTE: (OUT IN)Affected circuit breaker font sizeis reduced when reset. The resetcircuit breaker will automaticallybe removed from STATUS pagelist, after successful reset and anew page is selected.message goes out.
CB TRIP
THERM CB CAN’T BE CHANGED FROM CDU
NOTE:Will appear if an attempt to resetis carried out on a thermal circuitbreaker. A thermal breakercannot be reset using EMS CDU.The affected circuit breaker canonly be manually reset at itslocation.
Most recent tripped circuit breakerwill automatically highlight.To select another circuit breaker,use the line select key, thisacknowledges and highlightsthe displayed breaker.Once acknowledged or reset,the message goes out.CB TRIP
Select activation key adjacenthighlighted circuit breaker.
GX
_0
6_
01
0
ACPC
CCBP
M
CIRCUIT BREAKER - STATUS 1/1
STAB TRIM 1
STAB TRIM 2
FUEL COMPUTR CH B
DU 1
RAD ALT 1
AC1
AC ESS
DC ESS
DC ESS
DC 1
LOCKED
OUT
IN
LOCKED
TRIP
6-12 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC SYSTEM EICAS MESSAGES
1 . 65
789
EMER PWR ONLYIndicates that RAT ispowering AC ESS BUS,or batteries arefeeding DC ESS andbattery buses inemergency condition.
APU GEN OVLDIndicates an overloadon the APU generator.
CB TRIP AC FEEDIndicates that a circuitbreaker for an ACfeeder/AC cabin feederhas tripped.
GEN 1 (2,3,4) OVLDIndicates an overloadon affected generatorchannel.
RAT GEN FAIL(on ground only)Indicates that a fault hasbeen detected in the RATgenerator system duringbuilt-in test (BIT).
AC BUS 1 (2, 3, 4) FAILIndicates that affected busis not powered, or hasa fault.
AC ESS BUS FAILIndicates that AC ESSis not powered orhas a fault.
APU GEN OVERHEATIndicates that the APUgenerator oil hasoverheated.
CB TRIP DC FEEDIndicates that a circuitbreaker for a DC feeder/DC cabin feeder has tripped.
GX
_0
6_
011
EMER PWR ONLYAC BUS 1 FAILAC BUS 2 FAILAC BUS 3 FAILAC BUS 4 FAILAC ESS BUS FAILAPU GEN OVERHEATAPU GEN OVLDCB TRIP AC FEEDCB TRIP DC FEEDELEC SYS FAILGEN 1 OVLDGEN 2 OVLDGEN 3 OVLDGEN 4 OVLDRAT GEN FAIL
ELEC SYS FAILCAIMS level A fault.Prevents A/C dispatch untilfixed.
For Training Purposes OnlySept 04
6-13
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC SYSTEM EICAS MESSAGES
789
1 . 65
AC BUS 1 (2,3,4) XFER FAULTIndicates that transfer ofalternate power supply toaffected AC bus is lost.
CB TRIPIndicates that a circuitbreaker has tripped.
APU GEN FAILIndicates that APUGEN has failed.
RAT GEN ONIndicates that the RAT ispowering AC ESS BUSand is the only gen online
AC BUS 1 (2,3,4) MAN OFFIndicates that the affected bushas been manually isolated. All4 buses cannot be manuallyisolated concurrently.
RAT GEN OFFIndicates that the RAT isdeployed and the RAT lineconnector is selected off.
ELEC SYS FAULTIndicates loss ofredundancy on EGPDSlogic. CAIMS level Cfault. Fault must be fixedwithin 10 days.
EXT AC PWR AVAILIndicates that externalpower is available.
GEN 1 (2,3,4) FAILIndicates a GCU fault inthe applicable generator.
APU GEN OFFIndicates thatAPU GEN is selected off.
EXT AC PWR ONIndicates that externalAC power has beenselected on.
GEN 1 (2,3,4) OFFIndicates that affectedgenerator is selected off.
GX
_0
6_
01
2
AC BUS1 XFER FAULTAC BUS2 XFER FAULTAC BUS3 XFER FAULTAC BUS4 XFER FAULTAPU GEN FAILELEC SYS FAULTEXT AC PWR AVAILCB TRIPGEN 1 FAILGEN 2 FAILGEN 3 FAILGEN 4 FAILRAT GEN ONAC BUS 1 MAN OFFAC BUS 2 MAN OFFAC BUS 3 MAN OFFAC BUS 4 MAN OFFAPU GEN OFFEXT AC PWR ONGEN 1 OFFGEN 2 OFFGEN 3 OFFGEN 4 OFFRAT GEN OFF
6-14 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC SYSTEM SYNOPTICElectrical system warnings, cautions advisories and status messages are presented on the EICAS primary display. General views of airplane electrical systems (either AC or DC) are presented through synoptic diagrams on the EICAS secondary display (after selecting the appropriate key on the EICAS control panel).
STAT
HYDAC
ELECBLEED
AIRCOND
DCELEC
FUELFLT
CTRL
SCROLL
EICAS
SYSTEMS SELECT
NORMMFD 2MFD 1
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
11515
V
KVA
AC BUS 2
11512
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
11512
V
KVA
11515
V
KVA
GEN3
GEN4
GX
_0
6_
01
3
EICAS Control Panel
Generator VoltageReadoutDisplays, in VAC, thegenerator voltage level.• Green - 100 - 125VAC
• Amber - GCU fault• White - GEN off• Magenta - Invaliddata.
Generator LoadReadoutDisplays, in KVA, theload on the generator.
APU Generator Frequency ReadoutDisplays, in Hz, the generator frequencylevel.
Generator OutputFlow Line (Lower)• Green - Generatoris on.
• Blank - Generatoris off.
Generator OutputFlow Line (Upper)• Green - Generatorline contactor atgenerator position.• Blank - Generatorline contactor at tieposition.
For Training Purposes OnlySept 04
6-15
P I L O T T R A I N I N G G U I D E
ELECTRICAL
The AC electrical page contains digital readouts of generator output voltage, frequency (APU only), load in kVA, input/output flow on the bus bars, general status indications via color logic and the following messages:
• SHED message - Corresponding AC bus has been shed
• AC BUS 1, 2, 3, 4 MAN OFF icon - Corresponding AC bus is isolatedAC BUS 1, 2, 3, 4 MAN OFF status message displayed on EICAS
AC BUS FEED SYSTEMEach AC bus is normally powered by its own generator through generator line contactors. In the event of a generator malfunction, the priority system will automatically provide an alternate generator (feed), to power that bus (APU must be started to be available to the feed system), through generator transfer contactors.
The AC buses are normally powered by their own generator, but can be powered by alternate generators in the following descending order:
• AC BUS 1 - GEN 1, GEN 4, GEN 3, GEN 2, APU GEN • AC BUS 2 - GEN 2, GEN 3, GEN 4, APU GEN• AC BUS 3 - GEN 3, GEN 2, GEN 1, APU GEN• AC BUS 4 - GEN 4, GEN 1, GEN 2, GEN 3, APU GEN• AC ESS BUS - RAT generator (if deployed), GEN 4, GEN 1, GEN 2, GEN 3,
APU GEN. Normal power for AC ESS BUS is generator 4. When the RAT is deployed and RAT generator is ON, the AC ESS Bus is fed directly from the RAT generator
AC buses 2 and 3 are automatically load shed when a single generator is powering the buses.
External AC power will power all AC buses when selected ON and interacts with other generator power as per APU.
The AC bus feed is displayed on the AC ELECTRICAL synoptic page as follows:
GX
_0
6_
01
4AC BUS 2 AC BUS 3
SHED SHED
GX
_0
6_
01
5
AC BUS 1 MAN OFFAC BUS 2 MAN OFFAC BUS 3 MAN OFFAC BUS 4 MAN OFF
AC BUS 1
MAN OFF
Note:A maximum of 3 busses onlycan be manually isolatedconcurrently.
6-16 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC BUS 1
AC ELECTRICAL
0HZ
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
00
V
KVA
AC BUS 2
11512
V
KVA
GEN2
GEN1
AC BUS 3
11512
V
KVA
GEN3
AC BUS 1
AC ESS BUS
AC BUS 4
11524
V
KVA
GEN4
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
11512
V
KVA
AC BUS 2
11512
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
11512
V
KVA
11515
V
KVA
GEN3
GEN4
APU
GEN1
GEN4
GEN3
GEN2
GEN
GEN 1 GEN 4
GEN 3
APUGEN
GEN 2
AC BUS 1 -Normally powered by GEN 1, alternately powered by the following, in descending priority:
GX
_0
6_
01
6
PRIORITY
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
00
V
KVA
AC BUS 2
115V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
00
V
KVA
00
V
KVA
GEN3
GEN4
SHED SHED
AC ELECTRICAL
V
KVA
0000
V
KVA
GEN3
GEN4
00
V
KVA
00
V
KVA
11524
V
KVA
00
V
KVA
11524
V
KVA
AC BUS 2
AC ESS BUS
AC BUS 4
AC BUS 3
AC BUS 1
GEN
APU
GEN2
GEN1
GEN4
GEN3
00
V
KVA
V
KVA
GEN2
GEN1
11524
11528
400
V
KVA
HZ
GEN
APU
AC BUS 2 AC BUS 3
AC BUS 1
AC ESS BUS
AC BUS 4
For Training Purposes OnlySept 04
6-17
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC BUS 2
AC ELECTRICAL
AC BUS 1
11524
V
KVA
00
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
00
V
KVA
GEN4
AC BUS 2 AC BUS 3
11528
400
V
KVA
HZ
GEN
APU
00
V
KVA
GEN3
AC ELECTRICAL
AC BUS 2
AC ESS BUS
AC BUS 4
AC BUS 3
AC ELECTRICAL
AC BUS 1
11512
V
KVA
00
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
11524
V
KVA
GEN4
AC BUS 2 AC BUS 3
000
V
KVA
HZ
GEN
APU
11512
V
KVA
GEN3
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
11512
V
KVA
AC BUS 2
11512
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
11512
V
KVA
11515
V
KVA
GEN3
GEN4
APU
GEN2
GEN3
GEN4
GEN
GEN 2 GEN 3
GEN 4 APUGEN
AC BUS 2
GX
_0
6_
01
7
-Normally powered by GEN 2, alternately powered by the following, in descending priority:
PRIORITY
000
V
KVA
HZ
GEN
APU
00
V
KVA
GEN2
11524
V
KVA
GEN4
00
V
KVA
GEN3
11524
V
KVA
GEN1
AC BUS 1
6-18 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC BUS 3
AC ELECTRICALAC ELECTRICAL
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
11512
V
KVA
GEN1
AC ESS BUS
AC BUS 4
11524
V
KVA
GEN4
00
V
KVA
GEN3
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
11512
V
KVA
AC BUS 2
11512
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
11512
V
KVA
11515
V
KVA
GEN3
GEN4
APU
GEN3
GEN2
GEN1
GEN
GEN 3 GEN 2
GEN 1 APUGEN
AC BUS 3
GX
_0
6_
01
8
-Normally powered by GEN 3, alternately powered by the following, in descending priority:
PRIORITY
AC BUS 2 AC BUS 3
11512
V
KVA
GEN2
00
V
KVA
00
V
KVA
GEN2
GEN1
11524
V
KVA
GEN4
11528
400
V
KVA
HZ
GEN
APU
00
V
KVA
GEN3
000
V
KVA
HZ
GEN
APU
00
V
KVA
GEN2
11524
V
KVA
GEN4
00
V
KVA
GEN3
11524
V
KVA
GEN1
AC BUS 2
AC ESS BUS
AC BUS 4
AC BUS 3
AC BUS 1 AC BUS 1
AC ESS BUS
AC BUS 4
AC BUS 2 AC BUS 3
For Training Purposes OnlySept 04
6-19
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC BUS 4
AC ELECTRICAL
AC ELECTRICAL
AC ELECTRICAL
AC BUS 2
AC BUS 2
AC BUS 3
AC BUS 3
SHED
SHED
SHED
SHED
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 2
11512
V
KVA
GEN2
00
V
KVA
GEN4
AC BUS 3
11512
V
KVA
GEN3
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 2
11512
V
KVA
GEN2
AC BUS 3
11512
V
KVA
GEN3
AC BUS 1
AC ESS BUS
AC BUS 4
00
V
KVA
GEN4
V
KVA
GEN1
11512
APU
GEN4
GEN1
GEN2
GEN3
GEN
GEN 4 GEN 1
GEN 2 GEN 3
APU GEN
AC BUS 4
GX
_0
6_
01
9
-Normally powered by GEN 4, alternately powered by the following, in descending priority:
PRIORITY
0
0
0
0
V
V
KVA
KVA
V
V
KVA
KVA
GEN2
GEN2
GEN1
GEN1
115
0
32
0
400
0
V
V
KVA
KVA
HZ
HZ
GEN
GEN
APU
APU
V
V
KVA
KVA
0
0
0
115
0
0
0
32
V
V
KVA
KVA
GEN3
GEN3
GEN4
GEN4
0
0
0
0
AC BUS 1
AC BUS 1
AC ESS BUS
AC ESS BUS
AC BUS 4
AC BUS 4
AC ESS BUS
AC BUS 4AC BUS 1
11524
V
KVA
GEN1
AC BUS 2 AC BUS 3
AC BUS 1
AC ESS BUS
AC BUS 4
000
V
KVA
HZ
GEN
APU
00
V
KVA
11524
V
KVA
GEN2
GEN1
11524
V
KVA
00
V
KVA
GEN3
GEN4
6-20 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC ESS BUS
AC ELECTRICAL
00
V
KVA
AC BUS 2
V
KVA
GEN2
GEN1
AC BUS 3
SHED SHED
AC BUS 1
AC ESS BUS
AC BUS 4
11532
400
V
KVA
HZ
GEN
APU
V
KVA
0000
V
KVA
GEN3
GEN4
00
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
00
V
KVA
AC BUS 2
00
V
KVA
GEN2
GEN1
AC BUS 3
SHED SHED
AC BUS 1
AC ESS BUS
AC BUS 4
11532
V
KVA
00
V
KVA
GEN3
GEN4
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
00
V
KVA
11524
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
00
V
KVA
GEN4
11524
V
KVA
GEN3
AC BUS 1
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 2
11512
V
KVA
GEN2
11512
V
KVA
GEN3
AC BUS 1
AC ESS BUS
AC BUS 4
00
V
KVA
GEN4
V
KVA
GEN1
11512
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
11515
V
KVA
AC BUS 2
11512
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
11512
V
KVA
11515
V
KVA
GEN3
GEN4
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
00
V
KVA
AC BUS 2
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
V
KVA
V
KVA
GEN3
GEN4
0 0 00 0 0
115400
V
HZGENRAT
RAT GEN GEN 4
GEN 1 GEN 2
APUGEN
GEN 3
AC ESS BUS
GX
_0
6_
02
0
APU
GEN
GEN
RAT
GEN4
GEN1
GEN3
GEN2
NOTE: The RAT GEN has priority, only if it has been deployed and RAT GEN ON
-Normally powered by GEN 4, alternately powered by the following, in descending priority:
AC BUS 3 AC BUS 2 AC BUS 3
PRIORITY
ON
OFF
RAT GEN
For Training Purposes OnlySept 04
6-21
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EXT AC POWER
AC ELECTRICAL
EXTAC
1150
400
V
KVA
HZ
AC ELECTRICAL
GEN
APU
00
V
KVA
00
V
KVA
GEN2
GEN1
00
V
KVA
00
V
KVA
GEN3
GEN4
EXTAC
11523
400
V
KVA
HZ
EXTAC
1150
400
V
KVA
HZ
EXTAC
1150
400
V
KVA
HZ
• - Comes on to indicate thatexternal AC power is connected and is thecorrect phase, voltage and frequency.• - Indicates that external poweris being used or can be used by theairplane power distribution system tomaintain power to the AC buses.
AVAIL Light
ON LIGHT
NOTE:The ON light will remain illuminated, evenwhen another source(s) is powering ACbuses, to indicate that the priority systemcan call upon EXT AC if needed.
GX
_0
6_
02
1
EXTAC
11528
400
V
KVA
HZ
00
V
KVA
00
V
KVA
GEN2
GEN1
GEN
APU
00
V
KVA
00
V
KVA
GEN3
GEN4
AC BUS 1
AC BUS 2
AC ESS BUS
AC BUS 4
AC BUS 3
AC ESS BUS
AC BUS 4
AC BUS 3
AC BUS 1
AC BUS 2
11523
400
V
KVA
HZ
000
V
KVA
HZ
AVAIL
ON
EXT AC
AVAIL
ON
EXT AC
AVAIL
ON
EXT AC
6-22 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC SYSTEMThere are six primary DC power sources: four identical transformer rectifier units (TRU), an Avionics battery and an APU battery. All sources are routed through the DC power center (DCPC).
The six primary sources are monitored, switched, distributed and controlled by the DCPC. The DCPC reconfigures the buses automatically in the event of a TRU failure.
Four main DC buses provide DC power to the secondary airplane loads. Each TRU normally powers a bus, through a TRU line contactor (TLC). In the event of a TRU malfunction, the TRU transfer contactors (TTC), will automatically switch to an alternate TRU, to supply the affected bus. DC bus 1 and 2 are automatically shed during single TRU operations.
The avionics battery direct bus and DC emergency bus power is distributed to their secondary loads, through circuit breakers.
Two nickel cadmium batteries are installed in the airplane. Both batteries are used together in an emergency to provide DC power for a minimum of 15 minutes.
Each battery has a separate dedicated battery charger, to maintain that battery in a fully charged condition. The battery charger provides protection against battery overtemperature, defective or unbalanced cell, open/short battery temperature sense thermistor, open/short battery voltage sense lines and charger overtemperature. The charger will shut itself off and annunciate, when it senses a battery fault or charger fault.
External DC power is supplied to the airplane via DC external power receptacle. The APU start contactor assembly (ASCA) checks the power being delivered from the power unit, before connecting it to the airplane buses.
GX
_0
6_
02
2
External DC PowerReceptacle
For Training Purposes OnlySept 04
6-23
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC SYSTEM DISTRIBUTION
GX
_0
6_
02
3
ACBUS2A
ACBUS1A
ACESSBUS
DC BUS 1 DC BUS 2
TLC 1
TTC 2
TLC 3 TTC 4TTC 1
TLC 2
TTC 3 TLC 4
ETCK5
TRU 1ESS TRU 1
ESS TRU 1ESS TRU 2TRU 2TRU 1
ESS TRU 2ESS TRU 1TRU 2TRU 1
TRU 2ESS TRU 2
APU BATTDIRECT BUS
EXTDC
EXTPWR
EPC
AVIONICS BATTDIRECT BUS
EBBC 1K6
SSPC 4K10
SSPC 5K3 (ASCA)
SSPC 1K7
SSPC 2K8
SSPC 3K9
ETTC
TRU 1
ESS TRU 1
ESS TRU 2
TRU 2
AVIONICS BATT
APU BATT
EXT DC
AVIONICSBATTERY
APUBATTERY
ACBUS3A
K1
K1
K2
K3 K4
ESSTRU 2
TRU 2ESS
TRU 1TRU 1
CCBP
DCPC
ASCA
CR 1
CR 4
CR 6 CR 7
CR 5
CR 2 CR 3
CBC6
CBC4
DC ESS BUS BATT BUS
DCEMERGENCY
BUS
6-24 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
ELECTRICAL PANELExternal DC power is controlled manually. Battery master must be selected ON for all phases of flight.
ELECTRICALEXT AC
AVAIL
ON
FAIL
OFF
GEN 1
FAIL
OFF
EXT DC
AVAIL
ON
GEN 3 GEN 4
FAIL
OFF
GEN 2
FAIL
OFF
PUSH OFF/RESET
PUSHOFF/RESET
APU GEN
FAIL
OFF
RAT GEN
ON
OFF
BATT MASTER
EMS
OFF
ON
ASTE
E
OF
BATT MASTER Switch
OFF
EMS
ON
Used to control battery power.• - Isolates the battery busfrom the batteries.• - Electrical ManagementSystem is in maintenancemode. Batteries supply power toEMS only.• - Battery bus is poweredby battery (only if no AC poweron the airplane)
External DC Switch
AVAIL Light
ON Light
Displays status of DC external power:• - Comes on to indicatethat external DC power is connected andis operating limits.• - Indicates external DCpower is powering APU BATT DIR BUS.
within
GX
_0
6_
02
4
For Training Purposes OnlySept 04
6-25
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC SYSTEM EICAS MESSAGES
BATT MASTER OFFIndicates that thebattery switch is off.
BATT BUS FAILIndicates that batterybus is not powered,due to a fault.
DC EMER BUS FAILIndicates that DCEMER BUS is notpowered due to a fault.
APU (AV) BATT FAILIndicates that APU (AV)battery has failed, voltageor temperature is out ofrange.
DC BUS 1 (2) FAILIndicates that affectedDC bus is not powereddue to a fault or is shed.
DC ESS BUS FAILIndicates that DC ESS BUSis not powered, due to afault.
GX
_0
6_
02
5
789
1 . 65
APU BATT FAILAV BATT FAILBATT MASTER OFFBATT BUS FAILDC BUS 1 FAILDC BUS 2 FAILDC ESS BUS FAILDC EMER BUS FAIL
6-26 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC SYSTEM EICAS MESSAGES
789
1 . 65
GX
_0
6_
02
6
DC BUS 1(2) XFER FAULTDC ESS BUS XFER FAULTBATT BUS XFER FAULTIndicates that transfer ofalternate power supply toaffected bus is lost.
EXT DC PWR AVAILIndicates that externalDC power is available.
BATT EMER PWR ONIndicates that the batteriesare feeding the DC ESSBUS and BATT buses inan emergency condition.
BATT BUS MAN OFFDC BUS 1 (2) MAN OFFDC ESS BUS MAN OFFIndicates that affectedDC bus has beenmanually isolated.
APU (AV) BATT CHGR FAILIndicates that affected batterycharger has detected a faultand has shut down.
TRU 1 (2) FAIL orESS TRU 1 (2) FAILIndicates that affectedTRU has failed.
EXT DC PWR ONIndicates that externalDC power has beenselected on.
APU BATT CHGR FAILAV BATT CHGR FAILDC BUS1 XFER FAULTDC BUS2 XFER FAULTDC ESS XFER FAULTBATT BUS XFER FAULTEXT DC PWR AVAILBATT EMER PWR ONTRU 1 FAILTRU 2 FAILESS TRU 1 FAILESS TRU 2 FAILBATT BUS MAN OFFDC BUS 1 MAN OFFDC BUS 2 MAN OFFDC ESS BUS MAN OFFEXT DC PWR ON
For Training Purposes OnlySept 04
6-27
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC SYSTEM SYNOPTIC
The DC electrical page contains digital readouts of TRU and battery output (voltage and ampere output), input/output flow on the bus bars, generated status information via color logic and the following messages:
• CHARGER message (adjacent to APU BATT symbol) - APU battery is not charging. Corresponds to APU BATT CHGR FAIL advisory message
• CHARGER message (adjacent to AV BATT symbol) - Main airplane battery is not charging. AV BATT CHGR FAIL advisory message displayed on EICAS
• SHED message - Corresponding DC bus has been shed• MAN OFF message - Corresponding DC bus is isolated. DC BUS 1, (2) MAN
OFF, DC ESS MAN OFF and/or BATT BUS MAN OFF status message displayed on EICAS
DCELEC
STAT
HYDAC
ELECBLEED
AIRCOND
DCELEC
FUELFLT
CTRL
SCROLL
EICAS
SYSTEMS SELECT
NORMMFD 2MFD 1
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
28V
35A
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
28V
35A
AC BUS 3FEEDER
DC BUS 2
TRU 2
28V
35A
TRU 1
28V
35A
EICAS Control Panel
GX
_0
6_
02
7
6-28 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS FEED SYSTEMEach DC bus is normally powered by its respective TRU. Each TRU is normally powered by its own AC BUS FEEDER (ESS TRU 2 is powered by AC ESS BUS). In the event of a TRU malfunction, the priority system will automatically provide an alternate TRU feed to power the respective DC bus. As soon as one TRU fails, the emergency tie contactor (ETC) closes to allow power distribution.
ESS TRU 2 can be powered (through the AC ESS BUS) when the RAT is deployed and RAT generator is selected ON.
The DC buses are powered by the TRUs in the following descending order:
• DC BUS 1 - TRU 1, ESS TRU 1• DC ESS BUS - ESS TRU 1, ESS TRU 2, TRU 2, TRU 1• BATT BUS - ESS TRU 2, ESS TRU 1, TRU 2, TRU 1• DC BUS 2 - TRU 2, ESS TRU 2
DC BUS 1 and DC BUS 2 are automatically load shed when a single TRU is powering the buses. External DC power will power the APU BATT DIR BUS and consequently, the BATT BUS and the DC EMER BUS. External DC power is normally used by maintenance personnel or to start the APU in the event of a low APU BATT voltage. Note that a serviceable avionics battery is required to start the APU in this way.
The DC bus feed is displayed on the DC ELECTRICAL synoptic page as follows:
APU BATT CHGR FAILAV BATT CHGR FAILDC BUS 1 MAN OFFDC BUS 2 MAN OFFDC ESS MAN OFFBATT BUS MAN OFF
-10°C
AVBATT
20°C
APUBATTCHARGER CHARGER
DC BUS 2
SHED
DC BUS 1
MAN OFF
GX
_0
6_
02
8
For Training Purposes OnlySept 04
6-29
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 1
DC ELECTRICAL
AC BUS 2FEEDER
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2
2835
V
A
2835
V
A
GX
_0
6_
02
9
DC BUS 1
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
28V
35A
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
28V
35A
AC BUS 3FEEDER
DC BUS 2
TRU 2
28V
35A
TRU 1
28V
35A
TRU 1
2835
V
A
ESSTRU 12835
V
A
TRU 1
ESS TRU 1
-Normally powered by TRU 1, alternately powered by the following, in descending order:
ESSTRU 1
TRU 1
00
V
A
2845
V
A
DC ESS BUS
DC BUS 1
6-30 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC ESS BUS
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
2875
V
A
00
V
A
00
V
A
00
V
A
SHEDSHED
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
2835
V
A
2854
V
A
00
V
A
00
V
A
SHED
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
2835
V
A
2835
V
A
2845
V
A
00
V
A
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
28V
35A
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
28V
35A
AC BUS 3FEEDER
DC BUS 2
TRU 2
28V
35A
TRU 1
28V
35A
ESSTRU 1
ESSTRU 2
TRU 2 TRU 1
GX
_0
6_
03
0
DC ESS BUS
ESSTRU 12835
V
A
TRU 2
2835
V
A
ESSTRU 22835
V
A
TRU 1
2835
V
A
-Normally powered by ESS TRU 1, alternately powered by the following, in descending order:
For Training Purposes OnlySept 04
6-31
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BATT BUS
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
2875
V
A
00
V
A
00
V
A
00
V
A
SHEDSHED
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
2835
V
A
2854
V
A
00
V
A
00
V
A
SHED
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
2835
V
A
2835
V
A
00
V
A
2842
V
A
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
28V
35A
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
28V
35A
AC BUS 3FEEDER
DC BUS 2
TRU 2
28V
35A
TRU 1
28V
35A
ESSTRU 2
ESSTRU 1
TRU 2 TRU 1
GX
_0
6_
03
1
BATT BUS
ESSTRU 22835
V
A
TRU 2
2835
V
A
ESSTRU 12835
V
A
TRU 1
2835
V
A
-Normally powered by ESS TRU 2, alternately powered by the following, in descending order:
6-32 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 2
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
2835
V
A
00
V
A
2345
V
A
2842
V
A
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
28V
35A
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
28V
35A
AC BUS 3FEEDER
DC BUS 2
TRU 2
28V
35A
TRU 1
28V
35A
GX
_0
6_
03
2
DC BUS 2
TRU 2
2835
V
A
ESSTRU 22835
V
A
TRU 2
ESS TRU 2
-Normally powered by TRU 2, alternately powered by the following, in descending order:
For Training Purposes OnlySept 04
6-33
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EXTERNAL DC POWER
EXT DC
AVAIL
ON
EXT DC
AVAIL
ON
GX
_0
6_
03
3
APUBATT20°C
EXTDC
24
APUBATT20°C
0V
AEXTDC
AVAIL LightIndicates that external DC poweris connected (not on-line) and iswithin limits.
ON LightIndicates external DC power ispowering APU BATT DIR BUS.
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
26V 24V
0A 0A
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
DC EMERBUS
AVBATT
20°C
APUBATT
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
00
V
A
00
V
A
00
V
A
00
V
A
EXTDC
2410
V
A
AV BATTDIR BUS
BATT BUS
APU BATTDIR BUS
CHARGER CHARGER
6-34 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
RAT GEN FEEDEmergency AC power is supplied by the ram air turbine (RAT) in flight, rated at 115 volts, 9 kVA, 3-phase. With engines running, the RAT will deploy with a 14-second time delay following the loss of all AC power, if the slat/flap handle is at the in/zero position. It will deploy automatically if the slat/flap handle is not at the in/zero position. With a dual-engine failure, the RAT will deploy automatically, regardless of slat/flap handle position. The RAT can also be manually deployed by pulling RAT manual deploy handle, located on the center pedestal. Once deployed, the RAT will power the AC ESS BUS via the ram air turbine line contactor (RATLC).
This delay is implemented to allow the pilot to regain GEN 1-2-3 or 4, or APU GEN power.
NOTEThe AC ESS BUS will power ESS TRU 2 which will then feed the BATT BUS and the DC ESS BUS through the emergency tie contactor (ETC). Should ESS TRU 2 be unavailable, the emergency TRU tie contactor (ETTC) will close rerouting the power via ESS TRU 1.
In the event that an operating generator is restored, select the RAT GEN switch to OFF. The RAT GEN will remain in a standby mode.
RAT GEN
ON
OFF
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
00
V
KVA
AC BUS 2
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
V
KVA
V
KVA
GEN3
GEN4
0 0 00 0 0
115400
V
HZGENRAT
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
00
V
A
260
240
V
A
V
A
00
V
A
2875
V
A
00
V
A
RAT GEN
GX
_0
6_
03
4
CHARGER CHARGER
For Training Purposes OnlySept 04
6-35
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EMERGENCY DC POWERIn the event of loss of all AC power, or the airplane speed is 147 knots or less with the RAT deployed, a BATTERY EMER PWR ON EICAS message will be displayed. If the RAT is deployed and speed is less than 147 knots, the RAT GCU will automatically shed RAT electrical output, giving priority to hydraulics.
DC ELECTRICAL
AC BUS 2FEEDER
DC BUS 1
-10°C
AC BUS 1FEEDER
DC ESS BUS
ESSTRU 1
AC ESSBUS
BATT BUS
DC EMERBUS
AV BATTDIR BUS
AVBATT CHARGER CHARGER
20°C
APUBATT
APU BATTDIR BUS
ESSTRU 2
AC BUS 3FEEDER
DC BUS 2
TRU 2TRU 1
00
V
A
2624
2424
V
A
V
A
00
V
A
00
V
A
00
V
A
AC ELECTRICAL
000
V
KVA
HZ
GEN
APU
AC BUS 1
00
V
KVA
AC BUS 2
V
KVA
GEN2
GEN1
AC ESS BUS
AC BUS 4
AC BUS 3
V
KVA
V
KVA
GEN3
GEN4
0 0 00 0 0
0400
V
HZGENRAT
GX
_0
6_
03
5
147
180
170
160
150
140
130
120
1478
6
NOTE:Battery emergency power is available for a minimum of 15 minutes.
BATTERY EMER PWR ON
6-36 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC POWER EMERGENCY OVERRIDEIn the event of loss of all DC power, selecting the DC POWER EMERGENCY OVERRIDE switch (located on the pedestal) to OVERRIDE, will allow ESS TRU 1 and 2 to bypass the DCPC and power the SPDAs directly. All components normally powered by the DC ESS BUS and the BATT BUS will be powered directly from the ESS TRUs.
ELECT DC PWREMER OVRD
OVRD
NORM
20
10
30
20
10
30
09
8
7
65
4
3
2
1100 FEET
ALT
1 00032
4
10 13
mb/hPa
29 9 2
IN HG
IAS KNOTS
220200180 250
BARO
Honeywell HoneywellHoneywell Honeywell
WX
ET
NO BEARINGRA 9 . 8NM +13TA 4 . 5NM -04
SAT
GSPD
TERR
-56
TAT
TAS
-40
234
345
INHIB
LX
00 : 10 0 . 05L
MAG2HDG315
ETE 1+36
12 . 5KDVT
NM
FLBELOW
TCAS TEST
FMS1360
N
5 5
3
6
33
30
- 02
- 02
+ 12- 04
KABC
KKLM
KKLM
TOC
TOC
KGHJ
KGHJ
LUF
KDEF
KDEF
4000 4000
FL180
+ 09
TOTAL FUEL (LBS) 25750
1.021.02
25.425.4
443443
12950 1280000
NDSTAB
NU
RUDDERNL
LWD RWD
NR
AIL
– TRIMS –
6.0
N2
FF (PPH)
OIL TEMP
OIL PRESS
61.4690
7551
61.4690
8049
1 . 641 . 64
98.5 98.5
T/OEPR
N1
ITT
GEAR
PARK/EMER BRAKE ONNO TAKEOFF
IGN
START START
IGN
IN
0
DN DN DN
END
Honeywell
13000.00
00
90
13 13
2019 20
22 2220
OXYGEN
AFTCABIN (°C)
FWDCABIN (°C)
CKPT (°C)
OPEN OPEN
OUTFLOW VALVES
CAB ALT
P
CAB RATE
LDG ELEV
00
1 2
1 2
1 2
QTY
ENG
APU
RES
OIL (QTS)
APU DOOR 11.2°
RPM EGT
BRAKE TEMP
11.5
650100
0603 03 03
11.55.26.0
%
% %
Honeywell
9500
29.92
AT1
VTA
M
0.450M
FMS1LOC1DTK
360
HDG330
10400
20
20
10
10
20
20
10
10
9500
10500
300
220
210
200
190
180
170
F3
LE
F1
2160
150
1856
4
N33
30
W24
21S
15
12
E6
3
0
1
2
3
1
2
3
ATT
HDGT
EICAS
GS
LOC
HDG
RAD
IASALT
HDG2
VOR 1
ADF 2
0010020
80
THRUST HDG ASEL ATT 2AP1VAPP VNAV ADC 3
GX
_0
6_
03
6
DC POWER EMERGENCY OVERRIDE Switch
OVERRIDE
NORMAL
Used in the event of a total loss of DC powercontrol, to connect ESS TRU 1 and ESS TRU 2directly to the SPDAs to power the componentsnormally powered by the BATT BUS and DCESS BUS.
– SPDAs normally powered by theBATT BUS and DC ESS BUS are powereddirectly by the ESS TRU 1 and ESS TRU 2.
BATT BUS and DC ESS BUS arepowered by TRUs.
–
20
10
30
20
10
30
09
8
7
65
4
3
2
1100 FEET
ALT
1 00032
4
10 13
mb/hPa
29 9 2
IN HG
IAS KNOTS
220200180 250
BARO
Honeywell HoneywellHoneywell Honeywell HoneywellHoneywell
ELECT DC PWREMER OVRD
OVRD
NORM
For Training Purposes OnlySept 04
6-37
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EICAS PHILOSOPHYThe following represents the EICAS symbols and logic for the AC and DC synoptic pages. The symbols are shown in serviceable SHED, MAN OFF and failure conditions.
GX
_0
6_
03
7
ELECTRICAL SYSTEM LOGIC
BUS
TRUs
BATTERIES
POWEREDMAN OFF or
SHED FAILED INVALID
GEN
ENGINE
APU
RAT
OPERATINGNOT
OPERATING FAILED INVALID
RAT GEN GEN GEN GENRAT RAT RAT
EXT AC
EXT DC
ON FAILEDAVAILABLE INVALID
EXTAC
11528
400
VKVAHZ
EXTDC
240
VA
EXTAC
EXTDC
1150
400
2412
VKVAHZ
VA
EXTAC
EXTDC
000
2412
VKVAHZ
VA
EXTAC
EXTDC
000
2412
VKVAHZ
VA
6-38 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EMS CIRCUIT PROTECTION
COCKPIT CIRCUIT BREAKER PANEL (CCBP)
GX
_0
6_
03
8
69
14
13
12
11
10
87
54
32
1
ES
ST
RU
1A
LT
SL
AT
/F
LA
PP
WR
2
STA
BT
RIM
CH
2
ES
ST
RU
2
AC
ES
SB
US
20
15
15
15
69
14
13
12
11
10
87
54
32
1
ST
BY
PIT
OT
HT
R
AC
BU
S4
MO
NIT
OR
RA
TV
/FM
ON
ITO
R
TAT
HT
1L
AO
AH
TR
PIT
OT
1H
TB
PIT
OT
3H
TL
ICE
DE
TE
CT
OR
RA
OA
HE
AT
B
TAT
HT
2
LW
IND
OW
HE
AT
2.5
57
.57
.55
2.5
7.5
57
.51
57
.5
E F
69
13
12
11
10
87
54
32
1
LW
SH
LD
HT
R1
LW
SH
LD
HT
R2
SA
TC
OM
FR
EQ
UN
IT
RA
OA
HT
RA
RIC
ED
ET
EC
TP
ITO
T1
HT
AA
/TC
TL
RAC
BU
S1
2.5
7.5
2.5
7.5
20
20
5
69
13
12
11
10
87
54
32
1
SL
AT
/F
LA
PP
WR
1
TR
UB
AY
FAN
ES
ST
RU
1
15
20
2.5
G H
AV
BA
TT
RC
CB
AP
UB
AT
TR
CC
B
AV
BA
TT
HE
AT
TAT
HT
3
RW
SH
LD
HE
AT
1
RW
SH
LD
HE
AT
2
TR
U2
AV
BA
TT
CH
GR
PIT
OT
2H
T
RW
IND
OW
HE
AT
TR
U1
6
6 6
6
8 8
81
097 7
7
5
5 5
5
4
4 4
4
3
3 3
3
2
2 2
2
1
1 1
1
AC
BU
S2
AC
BU
S3
DC
15
7.5
15
15
7.5
20
20
5.5
5
ST
BY
AD
I
2.5
.5
A B C D
For Training Purposes OnlySept 04
6-39
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EMS CDUThe EMS CDU keys are used to access the following:
SYSTEM KEYThe SYSTEM key is used to access status and location of applicable system circuit breakers and to reset page from 1 to 2.
MM
CIRCUIT BREAKER - SYSTEM 2/2
HYD
ICE
IND/RECORD
LDG GEAR
LIGHTS
NAV
OIL
OXYGEN
THRUST REV
CIRCUIT BREAKER - SYSTEM 1/2
AFCS
AIR COND/PRESS
APU
BLEED
CAIMS
COMM
DOORS
ELEC
ENGINE
FIRE
FLT CONTROLS
FUEL
NEXTPAGE
PREVPAGE
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
03
9
CIRCUIT BREAKER - SYSTEM 1/2
AFCS
AIR COND/PRESS
APU
BLEED
CAIMS
COMM
DOORS
ELEC
ENGINE
FIRE
FLT CONTROLS
FUEL
PREVIOUS PAGE key usedto return to previous page.
NEXT PAGE key usedto scroll to next page.
6-40 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
ELEC SYSTEM KEY
M M M
MMM
MMM
MMM
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
0
CB - ELEC SYSTEM 1/12
AC 1 CABIN FEED
AC 2 CABIN FEED
AC 3 CABIN FEED
AC 4 CABIN FEED
AC BUS 1 FEED
AC BUS 2 FEED
AC 1
AC 2
AC 3
AC 4
AC 1
AC 2
ACPC
ACPC
ACPC
ACPC
IN
IN
IN
IN
IN
IN
CB - ELEC SYSTEM 5/12
BATT BUS FEED 1
BATT BUS FEED 2
FEED 3
BATT BUS FEED 4
DC1 CABIN FEED
DC2 CABIN FEED1
BATT BUS
BATT
BATT
BATT
BATT
DC 1
DC 2
IN
IN
IN
IN
IN
IN
CB - ELEC SYSTEM 9/12
EMS CDU 1 PWR B
EMS CDU 1/2 PWR C
EMS CDU 2 PWR A
EMS CDU 2 PWR B
ESS TRU 1 ALT
ESS TRU 1
BATT
EXT AC
BATT
AC 1
AC ESS
APU BATT
IN
IN
IN
IN
IN
IN
ACPC
ASCA
CCBP
CCBP
CB - ELEC SYSTEM 2/12
AC BUS 3 FEED
AC BUS 4 FEED
AC BUS 4 MONITOR
ACPC CTL PWR A
ACPC CTL PWR B
ACPC CTL PWR C
AC 3
AC 4
AC 4
BATT
DC ESS
DC 1
IN
IN
IN
IN
IN
IN
CCBP
CB - ELEC SYSTEM 6/12
DC 2 CABIN FEED 2
DC 2 CABIN FEED 3
DC BUS 1 FEED 1
DC BUS 1 FEED 2
DC BUS 1 FEED 3
DC BUS 1 FEED 4
DC 2
DC 2
DC 1
DC 1
DC 1
DC 1
IN
IN
IN
IN
IN
IN
CB - ELEC SYSTEM 10/12
ESS TRU 2
EXT AC INTERLOCK
EXT AC PBA LTS
GCU 1
GCU 2
GCU 3
AC ESS
EXT AC
EXT AC
BATT
BATT
BATT
IN
IN
IN
IN
IN
IN
CB - ELEC SYSTEM 3/12
ACPC CTL PWR D
APU BATT CHGR
APU BATT CHGR LD
APU BATT HEAT
APU BATT MSTR
APU BATT RCCB
APU BATT
AC 2
APU BATT
AC 4
APU BATT
APU BATT
IN
IN
IN
IN
IN
IN
ASCA
ACPC
ASCA
ACPC
ASCA
CCBP
CB - ELEC SYSTEM 7/12
DC BUS 2 FEED 1
DC BUS 2 FEED 2
DC BUS 2 FEED 3
DC BUS 2 FEED 4
DC EMER FEED 1
DC EMER FEED 2
DC 2
DC 2
DC 2
DC 2
AV BATT
BATT
IN
IN
IN
IN
IN
IN
CB - ELEC SYSTEM 11/12
GCU 4
RAT DEPLOY
RAT GCU TEST
RAT GEN HEATER
RAT U/H MONITOR
TRU 1
BATT
BATT
DC 1
DC 1
AC ESS
AC 2
IN
IN
IN
IN
IN
IN
CCBP
CCBP
CB - ELEC SYSTEM 12/12
TRU 2 AC 3 INCCBP
CB - ELEC SYSTEM 4/12
APU GCU
AV BATT CHGR
AV BATT CHGR LD
AV BATT HEAT
AV BATT MSTR
AV BATT RCCB
BATT
AC3
AV BATT
AC3
AV BATT
AV BATT
IN
IN
IN
IN
IN
IN
CCBP
DCPC
CCBP
DCPC
CCBP
CB - ELEC SYSTEM 8/12
DC ESS BUS FEED 1
DC ESS BUS FEED 2
DC ESS BUS FEED 3
DC ESS BUS FEED 4
DCPC EXT CTL PWR
EMS CDU 1 PWR A
DC ESS
DC ESS
DC ESS
DC ESS
EXT AC
AV BATT
IN
IN
IN
IN
IN
IN
ACPC
DCPC
DCPC
DCPC
CCBP
ACPC
ACPC
CIRCUIT BREAKER - SYSTEM 1/2
AFCS
AIR COND/PRESS
APU
BLEED
CAIMS
COMM
DOORS
ELEC
ENGINE
FIRE
FLT CONTROLS
FUEL
For Training Purposes OnlySept 04
6-41
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BUS KEYThe BUS key is used to display circuit breaker status and location by individual buses.
MM
MM
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
1CB - AC BUS 1 1/4
A/T CTLR
AC 1 CABIN FEED
AC BUS 1 FEED
ESS TRU 1
HYD PUMP 3B
L AFT PRI PUMP
IN
IN
IN
IN
IN
IN
CCBP
ACPC
CCBP
CB - AC BUS 1 3/4
PITOT 1 HT A
R AOA HEAT A
R ICE DETECTOR
SAT COM FREQ UNIT
SLAT/FLAP PWR 1
STAB TRIM CH 1
IN
IN
IN
IN
IN
IN
CCBP
CCBP
CCBP
CCBP
CCBP
ACPC
CB - AC BUS 1 2/4
L CTR XFER PUMP
L RECIRC FAN
L TAXI LT
L WING LDG LT
L WSHLD HEAT 1
L WSHLD HEAT 2
IN
IN
IN
IN
IN
IN
CCBP
CCBP
CB - AC BUS 1 4/4
TRU BAY FAN INCCBP
AC BUS 1
1/2CIRCUIT BREAKER - SYSTEM
AFCS
AIR COND/PRESS
APU
BLEED
CAIMS
COMM
DOORS
ELEC
ENGINE
FIRE
FLT CONTROLS
FUEL
CIRCUIT BREAKER - BUS 1/1
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
6-42 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC BUS 2
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
2
CB - AC BUS 2 1/2
AC 2 CABIN FEED
AC BUS 2 FEED
AFT TANK L PUMP
APU BATT CHGR
HYD PUMP 2B
L FWD PRI PUMP
IN
IN
IN
IN
IN
IN
ACPC
ACPC
CIRCUIT BREAKER - BUS 1/1
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
CB - AC BUS 2 2/2
PITOT 2 HT
R WINDOW HEAT
SATCOM AMP
TRU 1
IN
IN
IN
IN
CCBP
CCBP
ACPC
CCBP
M
M
CB - AC BUS 2 1/2
AC 2 CABIN FEED
AC BUS 2 FEED
AFT TANK L PUMP
APU BATT CHGR
HYD PUMP 2B
L FWD PRI PUMP
IN
IN
LOCKED
IN
IN
IN
ACPC
ACPC
CB - AC BUS 2 2/2
PITOT 2 HT
R WINDOW HEAT
SATCOM AMP
TRU 1
IN
IN
IN
IN
CCBP
CCBP
ACPC
CCBP
GLOBAL EXPRESS GLOBAL 5000
For Training Purposes OnlySept 04
6-43
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC BUS 3
MM
M M
GLOBAL EXPRESS GLOBAL 5000
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
3
CB - AC BUS 3 1/2
AC 3 CABIN FEED
AC BUS 3 FEED
AFT TANK R PUMP
AV BATT CHGR
AV BATT HEAT
HYD PUMP 1B
IN
IN
IN
IN
IN
IN
ACPC
CCBP
CCBP
CIRCUIT BREAKER - BUS 1/1
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
CB - AC BUS 3 2/2
R FWD PRI PUMP
R WSHLD HEAT 1
R WSHLD HEAT 2
TAT HT 3
TRU 2
IN
IN
IN
IN
IN
CCBP
CCBP
CCBP
CCBP
CB - AC BUS 3 1/2
AC 3 CABIN FEED
AC BUS 3 FEED
AFT TANK R PUMP
AV BATT CHGR
AV BATT HEAT
HYD PUMP 1B
IN
IN
LOCKED
IN
IN
IN
ACPC
CCBP
CCBP
CB - AC BUS 3 2/2
R FWD PRI PUMP
R WSHLD HEAT 1
R WSHLD HEAT 2
TAT HT 3
TRU 2
IN
IN
IN
IN
IN
CCBP
CCBP
CCBP
CCBP
6-44 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC BUS 4
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
4
CB - AC BUS 4 1/2
AC 4 CABIN FEED
AC BUS 4 FEED
AC BUS 4 MONITOR
APU BATT HEAT
APU OIL HEAT
AVIONICS FAN
IN
IN
IN
IN
IN
IN
ACPC
CCBP
ACPC
CB - AC BUS 4 2/2
HYD PUMP 3A
R AFT PRI PUMP
R CTR XFER PUMP
R RECIRC FAN
R TAXI LT
R WING LDG LT
IN
IN
IN
IN
IN
IN
1/1
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
CIRCUIT BREAKER - BUS
For Training Purposes OnlySept 04
6-45
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AC ESS BUS
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
5
CB - AC ESS BUS 1/3
ESS TRU 1 ALT
ESS TRU 2
L AOA HEAT
L ICE DETECTOR
L WINDOW HEAT
PITOT 1 HT B
IN
IN
IN
IN
IN
IN
CCBP
CCBP
CCBP
CCBP
CCBP
CCBP
CB - AC ESS BUS
CB - AC ESS BUS
2/3
3/3
PITOT 3 HT
R AOA HEAT B
RAT V/F MONITOR
SLAT/FLAP PWR 2
STAB TRIM CH 2
STBY PITOT HT
TAT HT 1
TAT HT 2
IN
IN
CCBP
CCBP
CCBP
CCBP
CCBP
CCBP
CCBP
CCBP
IN
IN
IN
IN
IN
IN
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
CIRCUIT BREAKER - BUS 1/1
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
6-46 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC EMER BUS
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
6
CB - DC EMER BUS 1/2
APU FIRE SOV
FIREX CH A
FIREX CH B
L ENG FUEL SOV
L HYD SOV
R ENG FUEL SOV
IN
IN
IN
IN
IN
IN
DCPC
DCPC
DCPC
DCPC
DCPC
DCPC
CIRCUIT BREAKER - BUS 1/1
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
CB - DC EMER BUS 2/2
R HYD SOV INDCPC
For Training Purposes OnlySept 04
6-47
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 1
MM
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
7
CB - DC BUS 1, SPDA1 1/3
A/T SERVOS
CKPT PRINTER
CLOCK 2
DU 3 PWR B
FMS 3 CDU
L FOOTWARMER
IN
IN
IN
IN
IN
IN
CB - DC BUS 1, SPDA 1 3/3
RAT GCU TEST
WX RADAR
WX RADAR CTLR 1
WX RADAR CTLR 2
RAT GEN HEATER
IN
IN
IN
IN
IN
CB - DC BUS 1, SPDA1 2/3
L NOSE LDG LT
NOSE STEER PWR 1
OVHD 2 INTG LTS
PBA BRT/DIM 1B
PBA BRT/DIM 3B
R WINDOW HEAT CTL
IN
IN
IN
IN
IN
IN
CIRCUIT BREAKER - BUS 1/1
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
CIRCUIT BREAKER - BUS 1/1
6-48 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 1 (Cont)
M
M
M
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
8
CB - DC BUS 1, SPDA2 1/3
ADF 1
AFT TANK L SOV C
AFT TANK L SOV O
AIRFONE REPEATER
AP 1 SERVOS
BRAKE CTL CH A
IN
IN
IN
IN
IN
IN
CB - DC BUS 1, SPDA2
CB - DC BUS 1, SPDA 2
2/3
3/3
CAB TEMP SENSOR
FLT CTL 1 CH A
IRS 3 PWR A
L BMC CH A
L ECS PRESS XDCR
L FRTT
L PACK CTLR CH A
P FEEL/RUD LIM 1
R PACK DUCT HEAT
RAD ALT 1
YD HEAT 1
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
1/1DC BUS 1 FEEDERS
GLOBAL EXPRESS GLOBAL 5000
CB - DC BUS 1, SPDA2 1/3
ADF 1
AFT TANK L SOV C
AFT TANK L SOV O
AIRFONE REPEATER
AP 1 SERVOS
BRAKE CTL CH A
IN
LOCKED
LOCKED
IN
IN
IN
CB - DC BUS 1, SPDA2
CB - DC BUS 1, SPDA 2
2/3
3/3
CAB TEMP SENSOR
FLT CTL 1 CH A
IRS 3 PWR A
L BMC CH A
L ECS PRESS XDCR
L FRTT
L PACK CTLR CH A
P FEEL/RUD LIM 1
R PACK DUCT HEAT
RAD ALT 1
YD HEAT 1
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
For Training Purposes OnlySept 04
6-49
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 1 (Cont)
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
04
9
CB - DC BUS 1, SPDA3 1/3
ACPC CTL PWR C
DAU 1 CH B
GPS 1
GPWS
HF 2 COUPLER
HF 2 TRANSCVR
IN
IN
IN
IN
IN
IN
CB - DC BUS 1, SPDA3
CB - DC BUS 1, SPDA 3
2/3
3/3
HYD 1 PRESS XDCR
IRS 3 FAN
LIGHTNING SENSOR
R BMC CH B
R PACK CTLR CH B
TAIL STROBE LTS
TOILET FAN
VIBE MONITOR
WING INSPECT LTS
WING STROBE LTS
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
DC BUS 1 FEEDERS 1/1
6-50 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 1 (Cont)
M
M
M
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
0
CB - DC BUS 1, SPDA4 1/3
ADC 2
AIRFONE SYSTEM
AUDIO PANEL 1A
AUDIO PANEL 3A
CAIMS PMAT LAPTOP
COPILOT INTG LTS
IN
IN
IN
IN
IN
IN
CB - DC BUS 1, SPDA4 2/3
DATA LINK
DAU 4 CH B
GEAR CTL A PWR 1
LIGHT DETECTOR
L LOGO LT
RMU 1 PWR A
IN
IN
IN
IN
IN
IN
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
DC BUS 1 FEEDERS 1/1
CB - DC BUS 1, SPDA4 3/3
IN
IN
IN
IN
IN
SATCOM ANT CTLR
SATCOM DATA UNIT
SELCAL
VHF COM 3 (OPT)
VOR/ILS 3 (OPT)
CB - DC BUS 1, SPDA4 1/3
ADC 2
AIRFONE SYSTEM
AUDIO PANEL 1A
AUDIO PANEL 3A
AV RACK FAN IN
CAIMS PMAT LAPTOP
IN
IN
IN
IN
IN
IN
CB - DC BUS 1, SPDA4 2/3
COPILOT INTG LTS
LIGHT DETECTOR
L LOGO LT
DATA LINK
DAU 4 CH B
GEAR CTL A PWR 1
IN
IN
IN
IN
IN
IN
CB - DC BUS 1, SPDA4 3/3
IN
IN
IN
IN
IN
IN
RMU 1 PWR A
SATCOM ANT CTLR
SATCOM DATA UNIT
SELCAL
VHF COM 3 (OPT)
VOR/ILS 3 (OPT)
GLOBAL EXPRESS GLOBAL 5000
For Training Purposes OnlySept 04
6-51
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 1 (Cont)
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
1
CB - DC BUS 1, CABIN 1/1
DC 1 CAB FEED IN
DC BUS 1 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
6-52 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 1 (Cont)
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
2MM
M
M
M
M
CB - DC BUS 1 1/13
A/T SERVOS
ACPC CTL PWR C
ADC 2
ADF 1
AFT TANK L SOV C
AFT TANK L SOV O
IN
IN
IN
IN
LOCKED
LOCKED
CB - DC BUS 1
CB - DC BUS 1
2/13
3/13
AIRFONE REPEATER
AIRFONE SYSTEM
AP 1 SERVOS
AUDIO PANEL 1A
AUDIO PANEL 3A
AV RACK FAN
BRAKE CTL CH A
CAB TEMP SENSOR
CAIMS PMAT LAPTOP
CKPT PRINTER
CLOCK 2
COPILOT INTG LTS
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 4/13
DATA LINK
DAU 1 CH B
DAU 4 CH B
DC 1 CAB FEED
DC BUS 1 FEED 1
DC BUS 1 FEED 2
IN
IN
IN
IN
IN
IN
CB - DC BUS 1
CB - DC BUS 1
5/13
6/13
DC BUS 1 FEED 3
DC BUS 1 FEED 4
DU 3 PWR B
FLT CTL 1 CH A
FMS 3 CDU
GEAR CTL A PWR 1
GPS 1
GPWS
HF 2 COUPLER
HF 2 TRANSCVR
HHD 1 PRESS XDCR
IRS 3 FAN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
DC BUS 1 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
MM
M
M
M
M
CB - DC BUS 1 1/12
A/T SERVOS
ACPC CTL PWR C
ADC 2
ADF 1
AFT TANK L SOV C
AFT TANK L SOV O
IN
IN
IN
IN
IN
IN
CB - DC BUS 1
CB - DC BUS 1
2/12
3/12
AIRFONE REPEATER
AIRFONE SYSTEM
AP 1 SERVOS
AUDIO PANEL 1A
AUDIO PANEL 3A
BRAKE CTL CH A
CAB TEMP SENSOR
CAIMS PMAT LAPTOP
CKPT PRINTER
CLOCK 2
COPILOT INTG LTS
DATA LINK
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 4/12
DAU 1 CH B
DAU 4 CH B
DC 1 CAB FEED
DC BUS 1 FEED 1
DC BUS 1 FEED 2
DC BUS 1 FEED 3
IN
IN
IN
IN
IN
IN
CB - DC BUS 1
CB - DC BUS 1
5/12
6/12
DC BUS 1 FEED 4
DU 3 PWR B
FLT CTL 1 CH A
FMS 3 CDU
GEAR CTL A PWR 1
GPS 1
GPWS
HF 2 COUPLER
HF 2 TRANSCVR
HHD 1 PRESS XDCR
IRS 3 FAN
IRS 3 PWR A
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
GLOBAL EXPRESS GLOBAL 5000
For Training Purposes OnlySept 04
6-53
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 1 (Cont)
M
M
M
M
M
M
M
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
3
CB - DC BUS 1 7/12
L BMC CH A
L ECS PRESS XDCR
L FOOTWARMER
L LOGO LT
L NOSE LDG LT
L FUEL RECIRC VLV
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 10/12
RAD ALT 1
RAT GCU TEST
RAT GEN HEATER
RMU 1 PWR A
SATCOM ANT CTLR
SATCOM DATA UNIT
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 8/12
LIGHT DETECTOR
L PACK CTLR CH A
LIGHTNING SENSOR
NOSE STEER PWR 1
OVHD 2 INTG LTS
P FEEL/RUD LIM 1
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 11/12
SELCAL
TAIL STROBE LTS
TOILET FAN
VHF COM 3 (OPT)
VIBE MONITOR
VOR ILS 3 (OPT)
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 9/12
PBA BRT/DIM 1 B
PBA BRT/DIM 3 B
R BMC CH B
R PACK CTLR CH B
R PACK DUCT HEAT
R WINDOW HEAT CTL
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 12/12
WING INSPECT LTS
WING STROBE LTS
WX RADAR
WX RADAR CTLR 1
WX RADAR CTLR 2
YD HEAT 1
IN
IN
IN
IN
IN
IN
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
DC BUS 1 FEEDERS 1/1
M
M
M
CB - DC BUS 1 7/13
IRS 3 PWR A
L BMC CH A
L ECS PRESS XDCR
L FOOTWARMER
L LOGO LT
L FUEL RECIRC VLV
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 10/13
R WINDOW HEAT CTL
RAD ALT 1
RAT GCU TEST
RAT GEN HEATER
RMU 1 PWR A
SATCOM ANT CTLR
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 8/13
LIGHT DETECTOR
L NOSE LDG LT
L PACK CTLR CH A
LIGHTNING SENSOR
NOSE STEER PWR 1
OVHD 2 INTG LTS
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 11/13
SATCOM DATA UNIT
SELCAL
TAIL STROBE LTS
TOILET FAN
VHF COM 3 (OPT)
VIBE MONITOR
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 9/13
P FEEL/RUD LIM 1
PBA BRT/DIM 1 B
PBA BRT/DIM 3 B
R BMC CH B
R PACK CTLR CH B
R PACK DUCT HEAT
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 12/13
VOR ILS 3 (OPT)
WING INSPECT LTS
WING STROBE LTS
WX RADAR
WX RADAR CTLR 1
WX RADAR CTLR 2
IN
IN
IN
IN
IN
IN
CB - DC BUS 1 13/13
YD HEAT 1 IN
GLOBAL EXPRESS
GLOBAL 5000
6-54 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 2
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
4
CB - DC BUS 2, SPDA1 1/3
AILERON TRIM
CB PNL INTG LTS
CKPT TEMP SENSOR
CTR 3 INTG LTS
CVR ERASE
DATA LOADER
IN
IN
IN
IN
IN
IN
CB - DC BUS 2, SPDA1 3/3
PBA BRT/DIM 2 B
R FOOTWARMER
R NOSE LDG LT
RMU 2 PWR A
IN
IN
IN
IN
CB - DC BUS 2, SPDA1 2/3
DAU 2 CH B
DU 6
FLOOR/EYE LTS
FMS 2 CDU
GALLY FAN
MFD 2 CTLR
IN
IN
IN
IN
IN
IN
DC BUS 2 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
1/1CIRCUIT BREAKER - BUS
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
For Training Purposes OnlySept 04
6-55
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 2 (Cont)
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
CB - DC BUS 2, SPDA2 1/3
DAU 3 CH B
DME 1
DU 4 PWR B
FDR
FDR ACCELEROMETER
GEAR CTL B PWR 1
IN
IN
IN
IN
IN
IN
CB - DC BUS 2, SPDA2
CB - DC BUS 2, SPDA2
2/3
3/3
HF 1 COUPLER
HF 1 TRANSCVR
HUMIDFIER
HYD 2 PRESS XDCR
IRS 2 PWR A
L BMC CH B
L PACK CTLR CH B
TRANSPONDER 1
VHF COM 1
VOR/ILS 1
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
DC BUS 2 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
GX
_0
6_
05
5
6-56 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 2 (Cont)
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
6
CB - DC BUS 2, SPDA3 1/2
AFT TANK R SOV C
AFT TANK R SOV O
GPS 2
IRS 2 FAN
L PACK DUCT HEAT
NAV LTS
IN
IN
IN
IN
IN
IN
CIRCUIT BREAKER - BUS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
CB - DC BUS 2, SPDA3 2/2
R BMC CH A
R PACK CTLR CH A
RAD ALT 2
IN
IN
IN
M
M
CB - DC BUS 2, SPDA3 1/2
AFT TANK R SOV C
AFT TANK R SOV O
GPS 2
IRS 2 FAN
L PACK DUCT HEAT
NAV LTS
LOCKED
LOCKED
IN
IN
IN
IN
CB - DC BUS 2, SPDA3 2/2
R BMC CH A
R PACK CTLR CH A
RAD ALT 2
IN
IN
IN
GLOBAL EXPRESS GLOBAL 5000
For Training Purposes OnlySept 04
6-57
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 2 (Cont)
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
7
CB - DC BUS 2, SPDA4 1/3
AP 2 SERVOS
AUDIO PANEL 2A
BEACON LT 1
BEACON LT 2
DU 5
FLT CTL 1 CH B
IN
IN
IN
IN
IN
IN
CB - DC BUS 2, SPDA4
CB - DC BUS 2, SPDA4
2/3
3/3
HUD
HUD CTL PANEL
NOSE STEER PWR 2
R ECS PRESS XDCR
R
R LOGO LT
FUEL RECIRC VLV
TRU BAY FAN CTL
YD HEAT 2
IN
IN
IN
IN
IN
IN
IN
IN
DC BUS 2 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
6-58 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 2 (Cont)
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
8
CB - DC BUS 2, CABIN 1/2
DC 2 CABIN FEED 1
DC 2 CABIN FEED 2
DC 2 CABIN FEED 3
IN
IN
IN
DC BUS 2 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
For Training Purposes OnlySept 04
6-59
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 2 (Cont)
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
05
9
M M
M M
M M
CB - DC BUS 2 1/11
AFT TANK R SOV C
AFT TANK R SOV O
AILERON TRIM
AP 2 SERVOS
AUDIO PANEL 2 A
BEACON LT 1
IN
IN
IN
IN
IN
IN
CB - DC BUS 2
CB - DC BUS 2
2/11
3/11
BEACON LT 2
CB PNL INTG LTS
CKPT TEMP SENSOR
CTR 3 INTG LTS
CVR ERASE
DATA LOADER
DAU 2 CH B
DAU 3 CH B
DC 2 CABIN FEED 1
DC BUS 2 FEED 1
DC 2 CABIN FEED 2
DC 2 CABIN FEED 3
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - DC BUS 2 4/11
DC BUS 2 FEED 2
DC BUS 2 FEED 3
DME 1
DU 4 PWR B
DU 5
DC BUS 2 FEED 4
IN
IN
IN
IN
IN
IN
CB - DC BUS 2 5/11
DU 6
FDR
FDR ACCELEROMETER
FLOOR/EYE LTS
FLT CTL 1 CH B
FMS 2 CDU
IN
IN
IN
IN
IN
IN
CB - DC BUS 2 6/11
GALLEY FAN
GEAR CTL B PWR 1
GPS 2
HF 1 COUPLER
HF 1 TRANSCVR
HUD
IN
IN
IN
IN
IN
IN
DC BUS 2 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
M M
M M
M M
CB - DC BUS 2 1/11
AFT TANK R SOV C
AFT TANK R SOV O
AILERON TRIM
AP 2 SERVOS
AUDIO PANEL 2 A
BEACON LT 1
LOCKED
LOCKED
IN
IN
IN
IN
CB - DC BUS 2
CB - DC BUS 2
2/11
3/11
BEACON LT 2
CB PNL INTG LTS
CKPT TEMP SENSOR
CTR 3 INTG LTS
CVR ERASE
DATA LOADER
DAU 2 CH B
DAU 3 CH B
DC 2 CABIN FEED 1
DC BUS 2 FEED 1
DC 2 CABIN FEED 2
DC 2 CABIN FEED 3
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - DC BUS 2 4/11
DC BUS 2 FEED 2
DC BUS 2 FEED 3
DME 1
DU 4 PWR B
DU 5
DC BUS 2 FEED 4
IN
IN
IN
IN
IN
IN
CB - DC BUS 2 5/11
DU 6
FDR
FDR ACCELEROMETER
FLOOR/EYE LTS
FLT CTL 1 CH B
FMS 2 CDU
IN
IN
IN
IN
IN
IN
CB - DC BUS 2 6/11
GALLEY FAN
GEAR CTL B PWR 1
GPS 2
HF 1 COUPLER
HF 1 TRANSCVR
HUD
IN
IN
IN
IN
IN
IN
GLOBAL EXPRESS GLOBAL 5000
6-60 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC BUS 2 (Cont)
M M
M M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
CB - DC BUS 2 7/11
HUD CTL PNL
HUMIDFIER
HYD 2 PRESS XDCR
IRS 2 FAN
IRS 2 PWR A
L BMC CH B
IN
IN
IN
IN
IN
IN
CB - DC BUS 2
CB - DC BUS 2
8/11
9/11
L PACK CTLR CH B
L PACK DUCT HEAT
MFD 2 CTLR
NAV LTS
NOSE STEER PWR 2
PBA BRT/DIM 2 B
R BMC CH A
R ECS PRESS XDCR
R FOOTWARMER
R FUEL RECIRC VLV
R LOGO LT
R NOSE LDG LT
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - DC BUS 2 10/11
R PACK CTLR CH A
RMU 2 PWR A
TRANSPONDER 1
TRU BAY FAN CTL
VHF COM 1
RAD ALT 2
IN
IN
IN
IN
IN
IN
GX
_0
6_
06
0
DC BUS 2 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
CABIN FEED
ALL
CB - DC BUS 2 11/11
VOR/ILS 1
YD HEAT 2
IN
IN
For Training Purposes OnlySept 04
6-61
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC ESS BUS
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
1
CB - DC ESS BUS, SPDA1 1/2
AUDIO PANEL 3B
CTR 1 INTG LTS
DU 2
FLOOD LTS
GUID PANEL CH 2
PILOT INTG LTS
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS, SPDA1 2/2
RAM AIR VLV
RMU 1 PWR B
RUDDER TRIM
STBY ALT/ASI
IN
IN
IN
IN
CIRCUIT BREAKER - BUS
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
DC BUS 2 FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
6-62 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC ESS BUS (Cont)
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
2
CB - DC ESS BUS, SPDA2 1/2
XFER SOV C
XFER SOV O
L AUX PUMP
L ECS HASOV
L ENG BLEED VLV
L ENG HP VLV
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS, SPDA2 2/2
L PACK CTV VLV IN
DC ESS BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
For Training Purposes OnlySept 04
6-63
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC ESS BUS (Cont)
M M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
3
CB - DC ESS BUS, SPDA 3 CB - DC ESS BUS, SPDA 31/3 3/3
ACPC CTL PWR B
AUTO PRESS 1
CVR
FLT CTL 2 CH A
FUEL COMPUTR CH B
IRS 1 FAN
R ECS HASOV
R ENG BLEED VLV
R ENG HP VLV
R PACK CTL VLV
SLAT/FLAP CTLR 2
YD2
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
2/3
IRS 1 PWR A
IRS 2 PWR B
IRS 3 PWR B
L WING A/ICE CTL
P FEEL/RUD LIM 2
R BMC SENSORS
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS, SPDA 3
DC ESS BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
6-64 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC ESS BUS (Cont)
M M
MM
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
4
CB - DC ESS BUS, SPDA 4 1/4
ADC 3
ADF 2
AURAL WARNING 2
AUTO PRESS 2
DME 2
DU 1
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS, SPDA 4 3/4
PUSHER LOCK CH B
R WING A/ICE CTL
SPC CH B
STICK SHAKER 2
TCAS
VOR/ILS 2
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS, SPDA 4 4/4
WAI XBLEED CNTL
WAI XBLEED VLV
IN
IN
CB - DC ESS BUS, SPDA 4 2/4
EMER LTS
FLT CTL 2 CH B
HBMU 2
IAC 2
L BMC SENSORS
L WNDOW HEAT CTL
IN
IN
IN
IN
IN
IN
DC ESS BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
For Training Purposes OnlySept 04
6-65
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC ESS BUS (Cont)
M
M
M
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
5
CB - DC ESS BUS 1/10
-> XFER SOV C
ACPC CTL PWR B
ADC 3
ADF 2
AUDIO PANEL 3B
-> XFER SOV O
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS
CB - DC ESS BUS
2/10
3/10
AURAL WARNING 2
AUTO PRESS 1
AUTO PRESS 2
CTR 1 INTG LTS
CVR
DC ESS BUS FEED 1
DC ESS BUS FEED 2
DME 2
DU 1
DU 2
DC ESS BUS FEED 3
DC ESS BUS FEED 4
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS 4/10
EMER LTS
FLOOD LTS
FLT CTL 2 CH A
FLT CTL 2 CH B
FUEL COMPUTR CH
GUID PANEL CH 2
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS
CB - DC ESS BUS
5/10
6/10
HBMU 2
IAC 2
IRS 1 FAN
IRS 1 PWR A
IRS 2 PWR B
IRS 3 PWR B
L AUX PUMP
L BMC SENSORS
L ECS HASOV
L ENG BLEED VLV
L ENG HP VLV
L PACK CTL VLV
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
DC ESS BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
6-66 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
DC ESS BUS (Cont)
M
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
6
CB - DC ESS BUS 7/10
L WINDOW HEAT CTL
L WING A/ICE CTL
P FEEL/RUD LIM 2
PILOT INTG LTS
PUSHER LOCK CH B
R BMC SENSORS
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS 8/10
R ECS HASOV
R ENG BLEED VLV
R ENG HP VLV
R PACK CTL VLV
R WING A/ICE CTL
RAM AIR VLV
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS 9/10
RMU 1 PWR B
RUDDER TRIM
SLAT/FLAP CTLR 2
SPC CH B
STBY ALT/ASI
STICK SHAKER 2
IN
IN
IN
IN
IN
IN
CB - DC ESS BUS 10/10
TCAS
VOR/ILS 2
WAI XBLEED CTL
WAI XBLEED VLV
YD 2
IN
IN
IN
IN
IN
DC ESS BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
For Training Purposes OnlySept 04
6-67
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BATT BUS
M
M
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
7
CB - BATT BUS SPDA 1 CB - BATT BUS SPDA 1
CB - BATT BUS SPDA 1 CB - BATT BUS SPDA 1
CB - BATT BUS SPDA 1
1/5 4/5
2/5 5/5
3/5
ADC 1
AUDIO PANEL 1B
AUDIO PANEL 2B
CLOCK 1
DU 4 PWR A
EMS CDU 2 PWR B
R ENG START B
R FADEC CH B
R FIRE HANDLE
R T/R TQA LOCK
RAT DEPLOY
RMU 2 PWR B
IAC 3
L FIRE HANDLE
MACH TRANSDUCER
MAN OUTFLOW VLV
OVHD 1 INTG LTS
OXYGEN
SPC CH A
STICK PUSHER PWR
STICK SHAKER 1
TRANSPONDER 2
PBA BRT/DIM 1 A
PBA BRT/DIM 2 A
PBA BRT/DIM 3 A
PUSHER LOCK CH A
R ENG FUEL HPSOV
R ENG IGN 2
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CIRCUIT BREAKER - BUS
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
BATT BUS FEEDERS 1/1
SPDA 1 FEED
SPDA 2 FEED
SPDA 3 FEED
SPDA 4 FEED
ALL
6-68 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BATT BUS (Cont)
M M
M M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
8
CB - BATT BUS SPDA 2 1/5
ACPC CTL PWR A
APU FIRE HANDLE
APU GCU
AURAL WARNING 1
CTR 2 INTG LTS A
DAU 1 ZH A
IN
IN
IN
IN
IN
IN
CB - BATT BUS SPDA 2
CB - BATT BUS SPDA 2
2/5
3/5
FIRE DETECT CH A
FMS 1 CDU
FUEL COMPUTR CH A
GCU 1
GCU 2
GEAR CTL B PWR 2
HBMU 1
IAC 1
IRS 1 PWR B
L COWL A/ICE VLV
L ENG IGN 1
L ENG START A
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - BATT BUS SPDA 2 4/5
L FADEC CH A
L T/R CTL VALVE
L T/R LOWER LOCK
L T/R UPPER LOCK
MAN PRESS 1
MAP LTS
IN
IN
IN
IN
IN
IN
CB - BATT BUS SPDA 2 5/5
MFD 1 CTLR
NO SMOKING SIGN
SLAT/FLAP CTLR 1
XFEED SOV C
XFEED SOV O
YD 1
IN
IN
IN
IN
IN
IN
BATT BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
For Training Purposes OnlySept 04
6-69
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BATT BUS (Cont)
M
M
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
06
9
CB - BATT BUS SPDA 3 1/5
XFER SOV C
VFER SOV O
APU FADEC PWR 1
APU LUBE
APU START
BRAKE CTL CH B
IN
IN
IN
IN
IN
IN
CB - BATT BUS SPDA 3
CB - BATT BUS SPDA 3
2/5
3/5
DAU 3 CH A
DAU 4 CH A
FIRE DETECT CH B
GCU 3
GCU 4
GEAR CTL A PWR 2
HYD 3 PRESS XDCR
L ENG LUBE
LUBE PUMP
MAN PRESS 2
PASSENGER ADDRESS
R AUX PUMP
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - BATT BUS SPDA 3 4/5
R COWL A/ICE VLV
R ENG IGN 1
R ENG LUBE
R ENG START A
R FADEC CH A
R T/R CTL VALVE
IN
IN
IN
IN
IN
IN
CB - BATT BUS SPDA 3 5/5
R T/R LOWER LOCK
R T/R UPPER LOCK
SEAT BELTS SIGN
XBLEED CTL
XBLEED VLV
IN
IN
IN
IN
IN
BATT BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
6-70 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BATT BUS (Cont)
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
0
CB - BATT BUS SPDA 4 1/2
DAU 2 CH. A
DU 3 PWR A
EMS CDU 1 PWR B
GUID PANEL CH 1
L ENG FUEL HPSOV
L ENG IGN 2
IN
IN
IN
IN
IN
IN
CB - BATT BUS SPDA 4 2/2
L ENG START B
L FADEC CH B
L T/R TQA LOCK
VHF COM 2
IN
IN
IN
IN
BATT BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
For Training Purposes OnlySept 04
6-71
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BATT BUS (Cont)
M M
M M
M M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
1
CB - BATT BUS 1/17
XFER SOV C
XFER SOV O
ACPC CTL PWR A
ADC 1
APU FADEC PWR 1
APU FIRE HANDLE
IN
IN
IN
IN
IN
IN
CB - BATT BUS
CB - BATT BUS
2/17
3/17
APU GCU
APU LUBE
APU START
AUDIO PANEL 1B
AUDIO PANEL 2B
AURAL WARNING 1
BATT BUS FEED 1
BATT BUS FEED 2
BATT BUS FEED 3
BATT BUS FEED 4
BRAKE CONT CH B
CLOCK 1
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - BATT BUS 4/17
CTR 2 INTG LTS
DAU 1 CH A
DAU 2 CH A
DAU 3 CH A
DAU 4 CH A
DC EMER FEED 2
IN
IN
IN
IN
IN
IN
CB - BATT BUS
CB - BATT BUS
5/17
6/17
DU 3 PWR A
DU 4 PWR A
EMS CDU 1 PWR B
EMS CDU 2 PWR B
FIRE DETECT CH A
FIRE DETECT CH B
FMS 1 CDU
FUEL COMPUTR CH A
GCU 1
GCU 2
GCU 3
GCU 4
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
BATT BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
6-72 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BATT BUS (Cont)
M M
M M
M M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
2
CB - BATT BUS 7/17
GEAR CTL A PWR 2
GEAR CTL B PWR 2
GUID PANEL CH 1
HBMU 1
HYD 3 PRESS XDCR
IAC 1
IN
IN
IN
IN
IN
IN
CB - BATT BUS
CB - BATT BUS
8/17
9/17
IAC 3
IRS 1 PWR B
L COWL A/ICE VLV
L ENG FUEL HPSOV
L ENG IGN 1
L ENG IGN 2
L ENG LUBE
L ENG START A
L ENG START B
L FADEC CH A
L FADEC CH B
L FIRE HANDLE
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - BATT BUS 10/17
L T/R CTL VALVE
L T/R LOWER LOCK
L T/R TQA LOCK
L T/R UPPER LOCK
LUBE PUMP
MACH TRANSDUCER
IN
IN
IN
IN
IN
IN
CB - BATT BUS
CB - BATT BUS
11/17
12/17
MAN OUTFLOW VLV
MAN PRESS 1
MAN PRESS 2
MAP LTS
MFD 1 CTLR
NO SMOKING SIGN
OVHD 1 INTG LTS
OXYGEN
PASSENGER ADDRESS
PBA BRT/DIM 1A
PBA BRT/DIM 2A
PBA BRT/DIM 3A
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
BATT BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
For Training Purposes OnlySept 04
6-73
P I L O T T R A I N I N G G U I D E
ELECTRICAL
BATT BUS (Cont)
M M
M M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
3
CB - BATT BUS 13/17
PUSHER LOCK CH A
R AUX PUMP
R COWL A/ICE VLV
R ENG FUEL HPSOV
R ENG IGN 1
R ENG IGN 2
IN
IN
IN
IN
IN
IN
CB - BATT BUS
CB - BATT BUS
14/17
15/17
R ENG LUBE
R ENG START A
R ENG START B
R FEDEC CH A
R FADEC CH B
R FIRE HANDLE
R T/R CTL VALVE
R T/R LOWER LOCK
R T/R TQA LOCK
R T/R UPPER LOCK
RAT DEPLOY
RMU 2 PWR B
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
CB - BATT BUS 16/17
SEAT BELTS SIGN
SLAT/FLAP CTLR 1
SPC CH A
STICK PUSHER PWR
STICK SHAKER 1
TRANSPONDER 2
IN
IN
IN
IN
IN
IN
CB - BATT BUS 17/17
VHF COM 2
XBLEED CTL
XBLEED VLV
XFEED SOV C
XFEED SOV O
YD 1
IN
IN
IN
IN
IN
IN
BATT BUS FEEDERS 1/1
SPDA1 FEED
SPDA2 FEED
SPDA3 FEED
SPDA4 FEED
ALL
6-74 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AV BATT BUS
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
4
CB - AV BATT BUS 1/2
APU FADEC PWR 2
AREA LTS
AV BATT CHGR LD
AV BATT MSTR
AV BATT RCCB
CLOCK BACKUP
DCPC
DCPC
DCPC
DCPC
CCBP
DCPC
IN
IN
IN
IN
IN
IN
CB - AV BATT BUS 2/2
DC EMER FEED 1
EMS CDU 1 PWR A
FWD MAINT LTS
PAX DOOR MOTOR
STAIR LTS
STBY ADI
IN
IN
IN
IN
IN
IN
DCPC
DCPC
DCPC
DCPC
DCPC
DCPC
DC ESS BUS FEEDERS 1/1
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
For Training Purposes OnlySept 04
6-75
P I L O T T R A I N I N G G U I D E
ELECTRICAL
APU BATT BUS
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
5
CB - APU BATT BUS 1/3
ACPC CTL PWRD
AFT MAINT LTS
APU BATT CHGR LD
APU BATT MSTR
APU BATT RCCB
APU DOOR
IN
IN
IN
IN
IN
IN
ASCA
ASCA
ASCA
ASCA
CCBP
ASCA
CB - APU BATT BUS 2/3
APU START CONTACT
CTR 2 TG LTS B
EMS CDU 2 PWR A
FUEL R/D CH A
FUEL R/D CH B
R/D MOTOR VALVES
IN
IN
IN
IN
IN
IN
ASCA
ASCA
ASCA
ASCA
ASCA
ASCA
3/3
R/D PANEL COCKPIT
R/D PANEL EXT
R/D SOL VALVES
IN
IN
IN
ASCA
ASCA
ASCA
CB - APU BATT BUS
CIRCUIT BREAKER - BUS 1/1
AC 1
AC 2
AC 3
AC 4
AC ESS
DC EMER
DC 1
DC 2
DC ESS
BATT
AV BATT
APU BATT
6-76 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
CNTL KEYCNTL Key is used to display system control options.
NOTESTALL WARN ADVANCE is either NORM or ADVANCE, see Chapter 10 for more information.
M
M
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
SWITCH CONTROL 1/3
SLAT/FLAP RESET
STALL WARN ADVANCE
LEFT FOOTWARMER
RIGHT FOOTWARMER
HUMIDIFIER
OFF
NORM
ON
ON
AUTO
SWITCH CONTROL 2/3
AC 1 CABIN PWR
AC 2 CABIN PWR
AC 3 CABIN PWR
AC 4 CABIN PWR
ON
ON
ON
ON
GX
_0
6_
07
6
SWITCH CONTROL 3/3
DC 1 CABIN PWR
DC 2 CABIN PWR 1
DC 2 CABIN PWR 2
DC 2 CABIN PWR 3
ON
ON
ON
ON
STBY
For Training Purposes OnlySept 04
6-77
P I L O T T R A I N I N G G U I D E
ELECTRICAL
TEST KEYTEST Key is used to display and initiate test options. When TEST key is selected, FIRE TEST is automatically highlighted. The TEST function can only be initiated by selecting the associated key. After a TEST is complete, the next selection will automatically be highlighted. To terminate a TEST, reselect appropriate key.
NOTEIndividual selection not covered.
M
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
7TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
OFF
OFF
OFF
OFF
OFF
OFF
STBY
M
TEST CONTROL 2/2
RAT TEST OFF
6-78 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
FIRE TEST
FIRE TEST:
(Duration approximately 15 seconds)
Press the FIRE TEST activation button and note the following:
• Fire aural warning is activated• Master warning lights flash• Fire DISCH handles lights illuminate• L and R ENG FIRE warning message comes on• APU FIRE warning message comes on• MLG BAY OVHT warning message comes on• SMOKE warning messages come on as per completion smoke detectors item• When the FIRE TEST is complete, all warning messages will go out, fire aural
warning deactivated, master warning lights go out and Fire DISC handles lights go out
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
8
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
TEST
OFF
OFF
OFF
OFF
OFF
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
07
9
TEST CONTROL 1/2
FIRE TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
STALL TEST
OFF
OFF
OFF
OFF
OFF
OFF
AFTER 10 SECONDS
For Training Purposes OnlySept 04
6-79
P I L O T T R A I N I N G G U I D E
ELECTRICAL
STALL TEST
STALL TEST
(Duration approximately 20 seconds)
Press the STALL TEST activation button and note the following:
• Stick shaker No. 1 activates, followed by stick shaker No. 2. Stall annunciated on PFD
• Both shakers are activated, stall aural warning is activated, both stalls are annunciated on both PFDs and IGN icon is present on EICAS
• Stick pusher is activated and both control columns move full forward and return to neutral twice
NOTEFor more information, refer to Chapter 10, FLIGHT CONTROLS.
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
08
0
TEST CONTROL 1/2
FIRE TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
STALL TEST
OFF
OFF
OFF
OFF
OFF
TEST
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_06_081
AFTER 20 SECONDS
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
AURAL WARNING TEST 1
OFF
OFF
OFF
OFF
OFF
OFF
6-80 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
AURAL WARNING TEST
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
08
2
Note:PressingTEST buttonagain willterminateaural test.
AFTER 60SECONDS
AURAL WARNING TEST:(during approximately 60seconds) Press the AURALWARNING TEST button andnote the following:
• “STALL” aural
• Overspeed tone
• Triple Chime tone (masterwarning)
• NO TAKEOFF” aural
• “LEFT ENGINE FIRE” aural
• “RIGHT ENGINE FIRE” aural
• “APU FIRE” aural
• “SMOKE” aural
• “CABIN ALTITUDE” aural
• “GEAR BAY OVERHEAT” aural
• “LEFT REVERSERUNLOCKED” aural
• “RIGHT REVERSER” aural
• “NORMAL BRAKE FAIL” aural
• Single Chime tone (anycaution)
• Double C-chord tone (verticaltrack alert)
• Trim clacker tone
• “MINIMUMS” aural
• “SELCAL” aural
• Aural Warning Test 1
“
UNLOCKED
• “GEAR” aural
• Autothrottle aural
• C-chord tone (altitude alert)
• Triple Cavalry Charge tone(autopilot)
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
AURAL WARNING TEST 1
OFF
OFF
OFF
OFF
OFF
TEST
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
LAMP TEST 1
LAMP TEST 2
AURAL WARNING TEST 2
OFF
OFF
OFF
OFF
OFF
OFF
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 2
LAMP TEST 1
OFF
OFF
OFF
OFF
OFF
OFF
For Training Purposes OnlySept 04
6-81
P I L O T T R A I N I N G G U I D E
ELECTRICAL
LAMP TEST
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
GX
_0
6_
08
3
AFTER 20SECONDS
AFTER 20SECONDS
LAMP TEST
(duration approximately20 seconds)
Press the LAMP TEST 1 (2)activation button and note thefollowing:
• All overhead pushbuttonannunciators illuminate
• Glareshield panel lightsilluminate
• Pedestal panel lightsilluminate
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 2
LAMP TEST 1
OFF
OFF
OFF
OFF
OFF
TEST
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
OFF
OFF
OFF
OFF
OFF
OFF
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 1
LAMP TEST 2
OFF
OFF
OFF
OFF
OFF
OFF
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
TEST CONTROL 2/2
RAT TEST TEST
RAT TEST
At the completion oft the test,confirm that a RAT GEN FAILcaution message is notdisplayed on EICAS.
6-82 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
EMER CNTLEMER CNTL Key used to display bus isolation status. To isolate a primary bus, (during an emergency), select associated activation key. When selected, associated bus is isolated from the electrical system (no alternate power transfer to bus).
DC BUS 1 MAN OFF
AC BUS 1 MAN OFF
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT
M
BRT
CIRCUIT BREAKER SYSTEM
STAT SYS BUSPREVPAGE
NEXTPAGE
CNTL TEST
BUS
EMERCONT G
X_
06
_0
84
AC BUS 1
MAN OFF
MAN OFF
DC BUS 1
STBY
BUS ISOLATION CONTROL 1/2
AC 1
AC 2
AC 3
AC 4
AC CABIN PWR
OFF
ON
ON
ON
ON
BUS ISOLATION CONTROL 2/2
DC 1
DC 2
DC ESS
BATT
DC CABIN PWR
OFF
ON
ON
ON
ON
For Training Purposes OnlySept 04
6-83
P I L O T T R A I N I N G G U I D E
ELECTRICAL
SYSTEM INTEGRATIONThe EPGDS associated with the Global Express is integrated into any on-board system which requires electrical power for its control, actuation or operation. As this includes virtually all aircraft systems, it is safe to say that the EPGDS may be considered to be the heart of the aircraft and central to its operation. As has been seen in previous sections, the pilot may access control of the EPGDS through the Cockpit Control Panel and the EMS CDU. The latter control device permits the manipulation of the vast majority of the electrical protection and controller components associated with all aircraft systems. As such, it allows unprecedented operator access to the EPGDS and the systems with which it is integrated. These systems and services may be identified by reviewing the CDU Display figures illustrated in the Operations section of this document.
6-84 For Training Purposes OnlySept 04
P I L O T T R A I N I N G G U I D E
ELECTRICAL
PAGE INTENTIONALLY LEFT BLANK