Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Embed Size (px)

Citation preview

Page 1: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Click to edit Master subtitle style

Mobile Test Suite

Installation and configuration

Paul Shepherd

Senior Repair Technician

Zebra Technologies Europe Limited

Page 2: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Download the latest version of Mobile Test Suite available at order.zebra.com

Page 3: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

When the download has completed install Mobile Test Suite by running the file Zebra Mobile Test Suite.msi and follow the instructions.

Page 4: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Once the program has been installed goto C:\Program Files\Zebra Mobile Test Suite\ and run Zebra Mobile Test Suite.exe

Page 5: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Mobile Test Suite will then open. Do not use the program yet. Click on the exit button.

Page 6: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Goto C:\bin and open the file Settings.xml using either Notepad or Wordpad.

Page 7: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

The Settings.xml will then open as seen below.

Page 8: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

The following settings need to changed (if necessary) :

Change <NetworkType> from ZGN to NONZGN Change <Function> from unreleased to released Ensure <LocalDownloadFilePath> is c:\

downloadfiles\ Change <Custom_Path> from S:\

Download_File_Path\ to C:\temp

Page 9: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Change <MZ_Parani_IP_Address>, <RW_Parani_IP_Address>, <QL_Parani_IP_Address>, <P4T_Parani_IP_Address> to the ip address of assigned to the Parani MSP-100

Change <SSID> to the SSID of the Wireless Access Point

Ensure <Bluetooth_Type> is set to parani Change <Location> from ca to custom Ensure <Reconfig> is set to false

Page 10: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Set <QL_ComPort>, <RW_ComPort>, <P4T_ComPort>, and <PS4000_ComPort> to the comport number you are using. By default this is com1

<Mirror_Path>, <Mirror_User>, <Mirror_Password>, <MirrorPasword_User_enable>, and <MirrorIp> do not require any changes.

Ensure <Authentication> is set to psk.

Page 11: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

If the Wireless Access Point is using WPA encryption set <WPA_Enable> to True

If the Wireless Access Point is not using any encrytion set <WPA_Enable> to False

Ensure <BoardTest> is set to True Ensure <Mirror_Enable> is set to False

Page 12: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Save and close the Settings.xml file If the Wireless Access Point is using WPA

encryption run Zebra Mobile Test Suite and then click on Actions on the menu bar and on the drop down menu select Security Settings. The following box will the appear:

Page 13: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Enter the PSK Key (Pre-shared key) for the Wireless Network and the click on Ok

Page 14: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

The Parani MSP-100 requires specific settings to be changed to work via Mobile Test Suite

Enter the IP address of the Parani MSP-100 into a web browser and enter the user name and password of the Parani MSP-100

Page 15: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Once logged into the Parani MSP-100 change the Maximum Connections from 14 to 7 and then click Apply

Page 16: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Click on Operation Mode and change Base Port in server mode from 5000 to 6000 and then click Apply

Page 17: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Before a printer can be tested using Mobile Test Suite the latest files need to be downloaded for the PCC number of the printer being tested

The files also need to be stored in the correct location so Mobile Test Suite can find the necessary files

Page 18: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Goto order.zebra.com and enter the PCC number of the printer in Product Search and click search

Page 19: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

The PCC number entered will then be found in the Search Results. Click on the PCC number link

Page 20: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

The Settings and Associated files for the printer will then be shown. Click the link DOWNLOAD ASSOCIATED FILES

Page 21: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

You will the be asked if you want to open or save this file. Click on Save

Page 22: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

When choosing where to save the file goto C:\temp and create a new directory with the PCC number of the printer. Save the ZIP file into this newly created directory

Page 23: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

After the download has complete goto the directory where the ZIP file was saved to

eg. C:\temp\Q4C-LUKCE011-00

Page 24: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Extact the contents of the ZIP file into this directory using your preferred ZIP extraction utility (winzip etc.)

Page 25: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

Create a new folder and give this folder the same name as the ZIP file which was downloaded.

eg. If the ZIP file was called SWQL420K-006.zip name the folder SWQL420K-006

Page 26: Click to edit Master subtitle style Mobile Test Suite Installation and configuration Paul Shepherd Senior Repair Technician Zebra Technologies Europe Limited

Mobile Test Suite

The ZIP file can then be deleted. Each time a printer with a different PCC number is

tested using Mobile Test Suite this process of downloading files needs to be repeated.

Installation and configuration of Mobile Test Suite is now complete and the program can be run and the instructions within the program followed.