4
The ever-changing environment of commercialconstruction offers exciting breakthroughs intechnology and materials, but it is not withoutsome heartburn. Today, owners, architects, andcontractors face many challenges in the design and
construction of their projects. Challenges such asusable space, indoor air quality, energy efficiency,maintenance costs, building longevity, and theLEEDprogram all come to the forefront of thedesign process. When considering the solutions tothese challenges, the type of HVAC system chosendirectly affects each one.
uSable SpaCe
It has been said that the reason real estate grows
in value is because no one is making any more. Ascities continue to grow and spread out, the valueof maximizing usable space becomes increasinglyimportant. When selecting an HVAC system, youpositively or negatively impact the usable spaceon a project. As an example,VAV (Variable Air Volume)systems utilize complicatedductwork systems alongwith extensive equipmentrooms to deliver conditioned
air into the building space.Additionally, VAV ductsystems many times requiremore ceiling height which increases floor-to-floor space thus increasing building costs. Bycomparison, ClimateMaster Water-Source andGeothermal Heat Pump systems require little tono equipment room space and use a very simple,compact, and independent ductwork system.
indoor air qualiTy
As important as the actual temperature of abuilding space is, the quality of air within thatspace is equally important. The American Societyof Heating, Refrigerating, and Air ConditioningEngineers (ASHRAE) has implemented Standard62, which requires significantly higher amounts offresh outdoor air for buildings. The challenge nowbecomes how to properly introduce, condition,and deliver this fresh air into the building space.Traditional options like two- and four-pipe Fan Coilsystems must be up-sized significantly to handle theadditional conditioning load. This means larger,more expensive units, larger, more expensivepiping, and larger, more expensive boilers andchillers. In comparison, ClimateMaster systemsoffer a variety of options that can actually lowerthe overall system size, introduce 100% outdoorair, and lower system usage cost.
energy effiCienCy
Todays offices equipped with computers, copiersand other office tools can dramatically affectthe heating and cooling load of a given space.When considering heating and cooling loads,rising energy costs demand an HVAC system
that is efficient while building designs require asystem that is also flexible. ClimateMaster has asolution for practically any application, and doesso with some of the most energy efficient HVACsystems available on the market today. In fact, allof ClimateMasters products either meet or exceedthe new federal mandated efficiency minimums.
mainTenanCe CoSTS
Complex systems such as two- and four-pipefan coils and VAV systems require advanced
maintenance and the trained personnel to
perform it. Large equipment rooms filled withchillers, air handlers, or large-scale boilers requirepersonnel for monitoring and maintenance,which consume building space and leasingprofits. The effect to the bottom l ine becomes
significant when considering the potential of acomplete system failure along with costly parts andequipment replacement. However, water-sourceand geothermal heat pumps require very littlemonitoring and maintenance - aside from routinefilter changes. With factory installed DDC controls,the entire building can be accessed via any web-enabled computer for monitoring and set pointcontrol. No muss, no fuss, no worries.
building longeViTy
New innovations offer longer life expectanciesfor todays buildings. You should expect the samefrom the HVAC systemsbeing placed inside thesebuildings. However, when itcomes to longevity, not allsystems are created equal.Complex chillers and airhandling systems often havea large number of movingparts that will wear outover time. Water-sourceand geothermal heat pumps offer the advantageof very few moving parts. Fewer moving partslower the occurrence of parts replacement andextend equipment life. This simplicity of designallows ClimateMaster systems to provide averagelife spans of 20 years or more. In fact, there area number of ClimateMaster units that are stillperforming after 50 years - providing the continualcomfort our customers have come to expect.
CommerCial HVaC
7/22/2019 Climate Master Com Proj LC007
6/48
5
many CHoiCeS, one SoluTion
When choosing a HVAC system for a project, thereare four basic types from which to choose.
fan CoilS
Fan coil systems are comprised of water-to-air coil airhandlers connected via a two- or four-pipe insulatedwater loop. Fan coils require complex chillers andboilers to provide water loop fluid in a particulartemperature range (i.e. chilled water for coolingand hot water for heating). Two-pipe fan coils havea major disadvantage as control is substantiallylimited to whatever mode the system is currently setat (i.e. cooling or heating). A four-pipe version canbe installed that requires both chilled and heatedwater to be available at the same time. Four-pipesystems also require twice the piping and twice thecirculation equipment of a two-pipe system, whichmakes a four-pipe system one of themost expensive systems to install.
Variable air
Volume (VaV)
Variable Air Volume, or VAV, is oneof the most common types of HVAC
systems used in large commercialbuildings today. A typical systemis usually comprised of a large airhandler, central ductwork system,and a relatively large equipmentroom. Conditioned air is distributedthroughout the building via a centralductwork system and is regulated viadampers in each space. VAV systemstypically have a higher first cost thanwater-source heat pumps, and may
have similar operating costs, resultingin overall increased life cycle costs.
roofTop
Rooftop systems are similar to VAV systems in thatthey use a central ductwork system to distributeconditioned air into the building space. However,instead of one central unit, the system is comprisedof multiple units which can be tasked for differentconditioning requirements. Rooftop systems usuallyrequire additional structural reenforcement as wellas cranes or other lifting equipment to place theunits. Control in a particular zone is limited to whatthe system is currently set to (i.e. cooling or heating).Rooftop installation costs are low to moderate, butoperating costs are typically 50% higher than water-source heat pumps. Additionally, the systems areexposed to the elements and are subject to damageand vandalism.
waTer-SourCe andgeoTHermal HeaT pumpS
Water-source and geothermal heat pump systemsare comprised of individual packaged unitsthat transfer heat via a single- or two-pipe water
loop. Each unit can be used in either heating orcooling mode year-round and loop temperature ismaintained via a boiler/tower combination or earth-coupled loop. Each zone has complete control of itsheating/cooling mode and each unit is independentfrom the others. This means if one unit goes down,the whole system is not af fected. Controls can be assimple as one unit, one thermostat. Water-source andgeothermal heat pump systems are the most energy,cost, and space efficient of any system inthe industry.
SySTem CompariSon
System
EaseofDesig
n
EaseofInstallation
InstallationSpa
ce
InstallationCo
st
MaintenanceRequirements
MaintenanceCosts
FutureSystemExpansion
SoundLevels
OperatingCosts
TotalZoneFailureC
hance
IndividualTenantC
ontrol
Options
AdditionalAuxiliary
EquipmentNeeded
Structure
ModificationNe
eds
SystemLongev
ity
Two-Pipe Fan Coils Low Low High Med High High Low Low Med High Low Low High High Med
Four-Pipe Fan Coils Low Low High High High High Low Low High High Low Low High High Med
PTAC / PTHP Low Low Low Low High High Med High High Low Med Low Med High Low
VAV Low Low High Med High High Low Med Med High Low Low High High Med
Rooftop Low Low High Low Med High Low Med Med High Low Low Med High Med
Water-Source Heat Pumps High High Low Low Low Low High Low Low Low High High Low Low High
Geothermal Heat Pumps High High Low Low Low Low High Low Low Low High High Low Low High
7/22/2019 Climate Master Com Proj LC007
7/48
7/22/2019 Climate Master Com Proj LC007
8/48
7
waTer-SourCe HeaT pumpS
Water-Loop heat pump systems combine water-source heat pumps on a common piping loopwith a heat rejector and boiler, which are used tomaintain the circulating water temperature within
a controlled range, typically from 60F to 95F[15C to 35C]. The most common heat rejectorsare open cooling towers with isolating heatexchangers, closed-circuit evaporative coolers, ordry coolers. Boilers are usually gas, oil, or electric.
Each zone heat pump utilizes the water loop toprovide heating or cooling at any time, during orafter hours, regardless of the operating mode ofthe other heat pumps. This is accomplished without
duplicate heat and cool distribution systems,without the double waste inherent in reheat modes,and without concurrent operation of the coolingsource and boiler, unlike most HVAC systems thatprovide the same capabilities.
Water-loop heat pump systems also operate veryefficiently at part-load conditions, such as whena small portion of the building remains occupiedafter hours. Only the required zone heat pumpsare used, unlike systems that must keep a large
central plant in operation at an inefficient scaled-back capacity in order to serve a small portion ofthe load.
A typical building has a perimeter with outsideexposure that is directly affected by variableoutdoor weather conditions and a core withoutoutside exposure that is almost unaffected bythe weather. In order to understand the energysharing benefits of a water-source heat pumpsystem, the interaction of the loads in the core andperimeter zones must be analyzed for occupied
periods (internal gains present) and unoccupiedperiods (temperature setback/setup and littleor no internal gains) throughout the year. Forillustration, the following are the main energyconsuming operating modes of an office building
in a temperate climate.
Summer oCCupied
All zones require cooling and are rejecting heatinto the water loop. The heat rejector maintains themaximum water loop temperature according to apredetermined setpoint (fixed or outdoor reset).The boiler is off.
winTer warm-up
During recovery from night setback, most zoneswill require heating and will be extracting heatfrom the water loop. The boiler maintains theminimum water loop temperature according to apredetermined setpoint. The heat rejector is off.The warm-up period is typically one hour or lessper day.
winTer oCCupied
Most core zones will require cooling because ofthe internal heat gains discussed previously. Mostperimeter zones will require heating. Because heatis being simultaneously rejected into and extractedfrom the water loop, both the boiler and the heatrejector remain off much of the time. The inherentsharing of energy within the water loop minimizesboiler and heat rejector operation and providesmaximum system efficiency.
SoluTion 1
7/22/2019 Climate Master Com Proj LC007
9/48
8
TCH120TCH120
TLV168
TCH012 TCH012 TCH012 TCH012 TCH012
TCH048 TCH048 TCH048
TCH024TCH024 TCH024 TCH024
TCH012
Office Office Office Office Office Office
OfficeConference Room Restroom Breakroom Computer Room
CubiclesCubicles
Lobby
Production Floor
MechanicalRoom
CoolingTower
Boiler
TCH120TCH120
TLV168
TCH012 TCH012 TCH012 TCH012 TCH012
TCH048 TCH048 TCH048
TCH024TCH024 TCH024 TCH024
TCH012
Office Office Office Office Office Office
OfficeConference Room Restroom Breakroom Computer Room
CubiclesCubicles
Lobby
Production Floor
MechanicalRo
om
CoolingTower
Boiler
warm weaTHer(HigH Cooling demand)
Cool weaTHer(HigH HeaTing demand)
a waTer-SourCe example
As an example of how water-source heat pumpscan handle a variety of different applications, thebuilding shown to the right is a fictional bronzestatue foundry company in the midwest portion
of the United States. The first floor comprises theirproduction floor and office space. The secondfloor of the building is reserved for future use.The cooling tower and boiler work as needed tomaintain an average loop temperature between 60to 95F [15 to 35C]. Water-source heat pumps canefficiently operate in either heating or cooling modeunder these conditions. This gives individual andspecialized zone control for maximum comfort andthe ability to change operation modes as needed.
A mixture of units in heating mode and unitsin cooling mode create a constant temperaturein the water loop. In Balanced Mode, t hereis no need for heat injection or rejection viathe boiler or cooling tower. The heat is simplymoved from one zone to another.
SoluTion 1 example
7/22/2019 Climate Master Com Proj LC007
10/48
9
geoTHermal SySTemS
These Boilerless/Towerless heat pump systemsuse the natural thermal properties of the Earthto dissipate or capture heat for the water loop.Geothermal heat pumps operate in an identical
fashion to water-source heat pump units. However,without the need for a boiler or cooling tower, theysave substantial energy costs and space. The waterloop system is underground and the units are insidethe building. Thus, the environmentally friendlygeothermal system preserves the architecturaldesign of a building naturally.
geoTHermal earTH loopS
Geothermal Earth Loops come in several different
configurations depending on space availabilityand soil properties. Chances are at some pointyou have either stood over, or walked across ageothermal loop field. Loop fields can be locatedunder parking lots, landscaped areas, or anynumber of other locations. All earth loops usehigh-density polyethylene pipe to circulate eitherwater or an antifreeze mixture. All joints andconnection fittings are thermally fused to preventleaks and most piping comes with a 25 year orlonger warranty.
VerTiCal loopS
Vertical loops utilize bore holes drilled to anaverage depth of 250 feet. Once the looppipe is inserted into the bore, it is groutedusing a Bentonite mixture for maximum thermalconductivity. When space is limited, verticalloops are the most common type of geothermal
loop installed.
HorizonTal loopS
Horizontal loops utilize trenches dug to an averagedepth of four to six feet. As one of the more costeffective loops to install, horizontal loops arecommonly found in open fields, parks or underparking lots.
lake loopS
Lake loops utilize a slinky assembly ofgeothermal loop piping placed at the bottom ofa pond, lake, or other large body of water. Anextremely cost effective loop system, lake loops arean easy alternative if the option is available.
well SySTemS
Most commonly known as Open Loop, wellsystems pump water out of a nearby body of wateror water well, and then discharge the water intoanother body of water or water well. Well systemsusually employ a plate heat exchanger inside thebuilding to keep the building water loop separatedfrom the well water. This prevents any contaminatesfrom affecting unit performance and extends systemlife. Well systems are often the most efficient as
the well water is always at the same temperatureyear-round.
SoluTion 2
7/22/2019 Climate Master Com Proj LC007
11/48
10
warm weaTHer(HigH Cooling demand)
a geoTHermal example
Using the same building model, the cooling tower andboiler are replaced with a geothermal vertical loopfield. Identical in overall zone operation, the buildingbenefits by having less overall equipment and reduced
operation costs. Building aesthetics are also improvedby eliminating outdoor equipment, and additionalspace is gained by eliminating the boiler and additionalsupport equipment.
TCH120TCH120
TLV168
TCH012 TCH012 TCH012 TCH012 TCH012
TCH048 TCH048 TCH048
TCH024TCH024 TCH024 TCH024
TCH012
Office Office Office Office Office Office
OfficeConference Room Restroom Breakroom Computer Room
CubiclesCubicles
Lobby
Production Floor S
torage
The cooling tower and boiler can be eliminated inthe geothermal application freeing up space used forequipment for other use. Only a small amount of room isneeded for loop circulation equipment.
SoluTion 2 example
7/22/2019 Climate Master Com Proj LC007
12/48
7/22/2019 Climate Master Com Proj LC007
13/48
12
wHo iS ClimaTemaSTer?
Who is ClimateMaster? ClimateMaster emergedfrom the marriage of several water-source heatpump companies in a blending of strengths to forma focused organization. For over 50 years, we
have been focused on enhancing business andhome environments around the world. Our missionas the worlds largest and most progressive leaderin the water-source and geothermal heat pumpindustry reveals our commitment to excellence- not only in the design and manufacture of ourproducts, but in our people and services.
made in THe uSa
All of ClimateMasters 610,000 square feet in
facilities operate in Oklahoma City, Oklahoma,which means ClimateMaster units and componentsare manufactured in the United States usingAmerican labor. While the trend nationally isto outsource labor outside the United States,ClimateMaster has made the commitment to remainproudly American made.
ClimaTemaSTer deSign
From concept to product, ClimateMastersIntegrated Product Development Team brings
a fusion of knowledge and creativity that isunmatched in the industry today. Drawing fromevery aspect of our business: Engineering, Sales,Marketing, and Manufacturing, our DevelopmentTeam has created some of the most advanced,efficient, and versatile products available.
innoVaTion, ConCepT, needS
Great products are born from necessity. Whetherit is a need to reduce sound, fit in a smaller space,make easier to service, achieve better efficiencies,or due to changing technologies, or new
government regulations, ClimateMaster leads theindustry in advancing the form, fit and function ofwater-source and geothermalheat pumps. Our Design Teamcontinually strives for even the
slightest improvement to ourproducts. It is this continualdrive for excellence that setsClimateMaster apart from allother manufacturers.
STarT To finiSH
At ClimateMaster, every product developmentproject begins with a comprehensive set ofspecifications. These specifications are aculmination of input from the market, a specif ic
need, or a number of other factors. Fromthese detailed specifications, prototypes areconstructed and testing begins. After a rigoroustesting period in ClimateMasters own state-of-the-art lab facility, the data is compared to theproject specifications. Once the Design Team issatisfied that all of the specs are met, the unit issent to the Production Department for pilot runs.After the pilot runs are completed, unit literatureis finalized and the product is released to themarketplace.
ClimaTemaSTer produCTion
Innovative products demand innovative manufacturingprocesses. ClimateMastersintegrated production processcombines every aspect of themanufacturing of our equipmentinto an organized, balanced, andcontrolled whole.
fabriCaTion
Every sheet-metal component of a ClimateMasterunit is produced in our Fabrication Department.Panels are precisely constructed of galvanizedor stainless steel using computerized cutting,
punching, and forming equipment. This precisefabrication means a tighter fit that makes for amore solid unit and reduced vibration, whichequals reduced noise. Oncertain series, an polyesterpowder coating is then appliedto increase corrosion resistanceand enhance the look ofthe unit. The final step is theaddition of fiberglass insulationto the inside as an additional layer of sound
deadening. This insulation meets stringent NFPAregulations, and includes antibacterial material.
aSSembly
ClimateMasters 610,000 square foot facilitiesuse the most stringent quality control standardsin the industry. Each unit is assembled underthe close supervision ofour Integrated ProcessControl System or Procix.
This multi-million dollarcomputer system watcheseach unit as it comesdown the assembly line.In addition, our Quality Department is stationedon each line and performs random audits notonly on the units, but also on component parts. Allcomponent parts must pass each and every qualitycheckpoint before a unit is packaged and shipped.These systems and processes are maximized dueto the comprehensive and ongoing training everyemployee receives from the date they are hired.
THe ClimaTemaSTer adVanTage
7/22/2019 Climate Master Com Proj LC007
14/48
13
ComponenT parTS
To produce a quality unit,you have to start with qualitycomponents. ClimateMastersPurchasing Department is
relentless in its search forthe best components for ourproducts - while securingthese components at prices that keep costs low.Any new component must go through a gruelingtesting phase before it ever sees the productionline. Working closely wit h vendors and theirengineers, we continually find new ways to notonly improve our units, but to ensure componentquality as well. Sister companies l ike KOAX,who produce our coaxial heat exchangers,
allow ClimateMaster to provide componentsspecifically designed for our applications.
iSo 9001:2000 CerTifiCaTion
International Organizationfor Standardization (ISO)is a network of the nationalstandards institutes ofover 150 countries, onthe basis of one member per country, with a
Central Secretariat of Geneva, Switzerland,that coordinates the system. ISO is a non-governmental organization that occupies aspecial position between the public and privatesectors whose goal is to create, maintain, andimprove standards worldwide. ISO standardscontribute to making the development,manufacturing, and supply of p roducts andservices more efficient, safer, and cleaner. ISOcertification demonstrates ClimateMasterscommitment to quality and continuousimprovement.
ClimaTemaSTer awardS
ClimateMaster leads theindustry in product awardsand certifications. From 100%Air-Conditioning, Heating
and Refrigeration Institute(AHRI) performance ratingsto industry awards for innovation, ClimateMasterapplies cutting-edge technology to every productwe design and manufacture.
ClimateMasters Tranquility 27 Series has wonmultiple awards and is widely accepted as aleader in the industry. You know you are doinggreat things when a lot of people tell you so.
engineering lab faCiliTieS
ClimateMaster has one of the largest testingfacilities of any water-source heat pumpmanufacturer including the reverberant, ISO3741 Certified sound testing room in the industry.Innovation and product improvements are amainstay of the ClimateMaster Engineering Lab.Our people are what make the difference in thedevelopment of superior products in a timelymanner. Our certified facility has seven automated
test cells capable of testing a wide variety of unittypes under varying conditions. These cells arecapable of producing data twenty-four hours aday, seven days a week. The development timeof equipment is significantly reduced allowingClimateMaster Engineers and Lab Techniciansto spend more time on the actual developmentprocess. This team effort has al lowed us to maintaina high degree of competence in our industry. Ourtest cells and test equipment are calibrated andcertified periodically, per recognized industrystandards, to insure the data is accurate andrepeatable. In addition to testing new concept
units, the lab continually audits production unitsthroughout the year to insure quality performanceand reliability.
induSTry affiliaTionSand aSSoCiaTionS
ClimateMaster works closelywith the International StandardsOrganization (ISO), the AmericanSociety of Heating, Refrigerating,and Air Conditioning Engineers(ASHRAE), and the Electrical TestingLaboratories (ETL), to insure thatour equipment not only meets thehighest performance standards,but meets the highest industry
standards as well. ClimateMasterhas celebrated many consecutiveyears of 100% success rate inAHRIs performance certificationprogram. An uncommon feat in the industry, thisis a testament to the craftsmanship, design, andconstruction of every ClimateMaster unit.
CuSTomer SerViCe
ClimateMaster hasgone to great lengths
to meet our customersbusiness-to-businessneeds. ClimateMasterprovides great productsand our customer support is second to none. Ourhighly trained and experienced Customer ServiceDepartment is available to assist you. Visit ouronline Business Center or contact Tech Services forany information you may need.
R
MAN UFACT
URER
CERT
IFIEDTOARIASCOMPLY
INGWI TH
ISO
STANDARD 1
3256
-1HEATPUMP
S
W A
TERTO
AIR BR
INE
TO
AI R
ISO 9001:2000Certified
Quality: First & Always
7/22/2019 Climate Master Com Proj LC007
15/48
14
ClimaTemaSTer.Com
Our web site has become the central hub for al l ofour customers information needs. Current literature,specifications, presentations, and other resourcesare readily available in an intuitive, easy-to-
navigate format. At the click of a mouse, our newonline Business Center allows you to check thestatus of your orders, lookup sales history, managecontact information, and even order literature,accessories, and equipment. Combined with ourunique EZ-ORDER software, we take all the effortand guesswork out of unit orders.
engineering deSignSpeCifiCaTionS
Advanced units need advanced specifications.
ClimateMasters new Engineering Designspecifications provide the most detailed informationfor your next project.
liTeraTure
At ClimateMaster, innovation never sleeps. Asnew advances are made, and new products arereleased, the need for accurate li terature becomescritical. Every piece of technical literature thatClimateMaster produces is printed in our state-of-
the-art on-demand printing facility. What this meansis that we print only the literature we need at thetime we need it. This insures that only the mostcurrent and accurate data is in the field.
SHipping
When you need that critical service part or pieceof literature for your next presentation, you mayrest assured that ClimateMaster has a shippingoption for you. Networked with a variety ofcarriers, we provide fast and reliable shipping to
anywhere in the world.
THe fuTure ofClimaTemaSTer
Our long history of innovation has paved theway for future endeavors with a solid platformof success. Growing markets in Europe and Asia
demand a different way of not only manufacturingour products, but also successfully marketingthem. Government regulations have phasedout R-22 refrigerant at the beginning of 2010paving the way for new HFC-410A, a much moreenvironmentally friendly refrigerant. In lookingahead, we continually strive for better processes,better designs, and better innovations that will keepClimateMaster as the global leader in water-sourceand geothermal heat pumps.
adVanTage exCluSiVeSBeing a leader in innovation, ClimateMaster bringsindustry firsts, as well as industry exclusives, to ourfamily of products.
ConTrolS
ClimateMaster offers two levels of solid-state digitalcontrols; the CXM and DXM control board.
CXM
Our standard CXM control board comesprogrammed with ClimateMasters UnitPerformance Sentinel (UPS) which monitors unitperformance and notifies the owner of potentialunit problems before a lockout occurs. Additionally,the CXMs eight standard safeties protect the unitfrom damage.
Anti-Short Cycle Low Voltage High Voltage High Refrigerant Pressure
Low Refrigerant Pressure(Loss of Charge)
Air Coil LowTemperature
Water Coil Low
Temperature Condensate Overflow
DXMOur enhanced controls option, the DXM controlboard offers all of the advantages of the CXMboard but adds the following addi tional features:
Multi-Stage Operation Night Setback with
Override
Emergency Shutdown Reheat Control Boilerless Electric Heat
DDC ControlsFactory mounted LONWorks or Multi-ProtoCol(MPC) DDC controllers are an available optionon all ClimateMaster products. These controllersgive owners the ability to implement a variety ofbuilding automation systemssuch as BACnet, ModBus,
and Johnson N2. Through aweb enabled PC, individualunits, unit zones, and entirebuilding systems can bemonitored and controlledwith the click of a mouse.The systems provide unit status, set-point control,performance curves, and fault indications.
7/22/2019 Climate Master Com Proj LC007
16/48
15
ConfiguraTionS
No other manufacturer provides as many size,performance, configuration, and cost options asthe ClimateMaster family of products offers. Fromour smallest horizontal unit in the TCH-006, to
our largest vertical in the TLV-300, to our RooftopSeries with available 100% make-up air (whenmated with the Rx ERV), to the vertical stack,console, water-to-water, and two-stage Tranquility27, we have a unit to fit your application.
Sound
Prior to the adoption of the 260-2000 soundstandard there had been no standard for theevaluation of water-source heat pump soundperformance. Also, those manufacturers who didgenerate and publish their own sound data, didso in their own labs making it difficult to havethe data independently certified and accuratecomparisons were therefore, impossible. Nowthat a standard has been established, it is criticalto compare the data correctly. If data fromtwo manufacturers is compared using differenttest procedures, results are not comparable.ClimateMaster has tested its product line for bothducted discharge and free inlet air combinedwith case radiated tests. Comfort has never beenso quiet with our intelligent sound design. Ourproducts use a variety of technologies to maintainour lead as the quietest units in the industry.
dual leVel VibraTioniSolaTion
ClimateMaster units use anexclusive double isolationcompressor mounting system.This dual level isolation
deadens vibration andprovides quiet operation.
TorSion-flex blowerS
Blower motors, on select models,are mounted with a uniquetorsion-flex mounting systemwhich not only allows for easy
service, but also reduces vibrationfrom the blower motor duringoperation.
ulTraquieT
ClimateMasters optional additional soundsuppression package enhances our alreadyexcellent sound performance through the useof dual density acoustical insulation and otherstrategically placed sound attenuating materials.No other manufacturers mute package comesclose to matching the performance of theUltraQuiet package.
e-CoaTed air CoilSand waTer CoilS
All ClimateMaster water-source heating andcooling systems are available with an E-Coated air-coil option. E-Coated or Powder Coated water coilsare standard on all products. This process providesyears of protection against coil
corrosion from airborne chemicalsresulting from modern buildingmaterial outgassing and mostairborne environmental chemicals.In fact, ClimateMasters exclusiveE-Coated air-coils enhancecorrosion protection to nearly 20times that of a traditional uncoated coil.*
*Test based upon ASTM B117 Salt Spray test hours.
Climadry reHeaT
Continuing to lead the industry in IAQ (Indoor AirQuality) solutions, select ClimateMaster units areavailable with an innovative method (patented) ofreheating the air. The ClimaDry microprocessor-
controlled option will automatically provide 100%reheat by adjusting the amount of reheat capacitybased upon supply air temperature. This newapproach to reheat provides dehumidified, neutraltemperature supply air, while eliminating the problemof overcooling the space when loop temperaturesdrop. All components are internal to the unit,saving space and keeping installation costs low.A simple humidistat or dehumidistat control activatesthe option.
VolTageS
ClimateMaster units are available in a wide varietyof commercial voltages, providing maximumflexibility in building design. Available voltages areas follows:
208-230/60/1 208-230/60/3 265/60/1 460/60/3 575/60/3
* Not all units are available with every voltage combination shown above.
aCCeSSorieS
ClimateMaster offers a complete line ofaccessories to complete any project, includinghoses, thermostats, valves, pumps, fittings,controllers, sensors, filters and more.
7/22/2019 Climate Master Com Proj LC007
17/48
7/22/2019 Climate Master Com Proj LC007
18/48
T H E C L I M A T E M A S T E R F A M I LY O F P R O D U C T S
7/22/2019 Climate Master Com Proj LC007
19/48
Product Series
Standard Features Factory Installed Options
EarthP
ure
(HF
C-41
0A
)R
efrig
eran
t
Micro
pro
cessor
CXM
Con
trols*
Stan
dardR
an
ge
CopperW
ater
Coil**
TXV
DualL
ev
el
Com
pre
ssor
Vibra
tionIsola
tion
Field
Conv
ertibleDisch
arg
e
(Horizon
tal
Units)
MultipleA
ccessP
an
elsforIn
stalla
tion
an
dServiceE
ase
Scroll
Com
pre
ssors
FactoryIn
stalle
dH
an
gerBra
ckets
(Horizon
tal
Units)
Rem
oteR
esetatTh
erm
ostat
Con
den
sateOverflowPro
tection
Cupro-Nick
el
Coil
High
StaticBlow
er
UltraQ
uie
t(Mute)P
ackage
Ex
ten
dedR
an
ge(20to12
0F
)
Auto-FlowW
aterR
egula
tion
Two-W
ayCon
trolV
alve
DownFlow
Config
ura
tion
Desuperh
eater
Coil
DD
CCon
troller
Delux
eDXM
Con
troller
E-C
oatedAir
Coil
Intern
al
Secon
daryP
um
p
ECMF
an***
Clim
aDryR
eh
eat
Intern
al
Servic
eDisconn
ect
Tranquility 27Two-Stage (TT)
Tranquility 20 Single-Stage (TS) TranquilityHigh Efficiency (TR) a Tranquility 16 Compact (TC) a Tranquility Vertical Stack (TRM) a
Tranquility Console (TRC)
Tranquility Compact (TCH)
Tranquility Large (TL) c
Tranquility Water-to-Water (TMW) b
Rooftop (TRE)
Rx Energy Recovery Ventilator (ERV)
Vertical Dedicated Outdoor Air (TO)
Horizontal Dedicated Outdoor Air (TO)
* Standard control for TO Series is DDC with modulating HGR. ** Standard water coil construction for TO Series is stainless steel.*** Standard on TT Series Standard on TMW Series Extended Range = 35F95F EWT
a Sizes 024 and above b Sizes 036 - 120 c Vertical series only
U N I T F E A T U R E S
ROOFTOP(TRE)SERIES
ThreetoTwentyTonRooftopUnits
TRANQUILITYVERTICALSTACK(TRM)SERIES
Three-QuartertoThreeTonEarthPure
(HFC-410A)Vertical
Hi-RiseStackUnits
TRANQUILITY(TOH)SERIES
ThreetoOneHundredTonHorizontalDedicatedOutdoor
AirSystems
TRANQUILITY(TOV)SERIES
FourtoThirtyTonVerticalDedicatedOutdoor
AirSystems
TRANQUILITYMODULARWATER-TO-WATER(TMW)SERIES
ThreetoTwenty-EightTon
EarthPure(HFC-410A)
Water-to-WaterUnits
TRANQUILITYCONSOLE(TRC)SERIES
Three-QuartertoOne-and-OneHalfTon
EarthPure(HFC-410A)
ConsoleUnits
TRANQUILITYLARGE(TL)SERIES
SeventoTwenty-FiveTon
EarthPure(HFC-410A)
VerticalUnits
TRANQUILITY20SINGLE-STAGE(TS)SERIES
One-HalftoSixTonSingle-StageEarthPure
(HFC-410A)
Horizontal,Vertical,andDownflowUnits
TRANQUILITY27
TWO-STAGE(TT)SERIES
TwotoSixTonTwo-StageEarthPure
(HFC-410A)
Horizontal,Vertical,andDownflowUnits
TRANQUILITY16COMPACT(TC)SERIES
One-HalftoFiveTonCompactEarthPure
(HFC-410A)
HorizontalandVerticalUnits
TRANQUILITYCOMPACT(TCH)SERIES
SixtoTenTon
CompactEarthPure(HFC-410A)
HorizontalUnits
TRANQUILITYHIGHEFFICIENCY(TR)SERIES
One-HalftoFiveTonEarthPure
(HFC-410A)
HorizontalandVerticalUnits
Rx(ERV)MODULE
RooftopEnergyRecoveryUnits
T H E C L I M A T E M A S T E R F A M I L Y O F P R O D U C T S
7/22/2019 Climate Master Com Proj LC007
20/48
7/22/2019 Climate Master Com Proj LC007
21/48
20
The Tranquility 27Two-Stage (TT) Series blends themost advanced technology with the most advanceddesign to create some of the highest efficiency water-source heat pumps available today.
The Tranquility 27Two-Stage Series utilizesEarthPure(HFC-410A) refrigerant along with theCopeland UltraTech two-stage compressor and
ECM variable speed motor to bring unmatchedperformance and comfort.
uniT feaTureS
Sizes 026 (2 ton, 7.0 kW) through 072 (6 ton,21.1 kW)
Environmentally-friendly EarthPureHFC-410A refrigerant
Unsurpassed efficiencies (far exceeds ASHRAE 90.1) Copeland UltraTech two-stage compressor and
variable speed ECM fan motor
Galvanized steel construction and powder coatpaint on all units
Unique double isolation compressor mounting forquiet operation
Discharge muffler standard on all sizes forsuperior sound attenuation
Microprocessor controls standard (optional DXMand/or DDC controls)
Field convertible discharge air arrangement forhorizontal units Bi-directional, balanced port expansion valve
refrigerant metering device standard Standard range or extended range operation Water connections securely mounted flush to the
cabinet corner post (no backup wrench required) Eight safeties standard
THe TranquiliTy 27Two-STage (TT) SerieS
Easy to remove blowerhousing for quick serviceand ECM variable speedmotor
Foil faced insulation in the
blower section and fiberglassinsulation in the compressorsection
Copeland UltraTech two-stage compressorwith dual compressorvibration isolation
Easy service access frommultiple sides
Easy access control boxcontains advanced digitalcontrols with Remote ServiceSentinel (Optional Enhancedcontrols (DXM) & DDCControllers)
Factory installed hangerbrackets on horizontal units
Standard stainless steelinsulated drain pan withcondensate overflowprotection
7/22/2019 Climate Master Com Proj LC007
22/48
21
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TT-026 HFC-410A 25,300 [7.42] 15.9 [4.7] 30,800 [9.03] 5.3 28,900 [8.47] 24.5 [7.2] 25,700 [7.53] 4.8 26,600 [7.80] 18.5 [5.4] 19,800 [5.80] 4.0
TT-038 HFC-410A 36,200 [10 .61] 15 .6 [4.6] 44 ,800 [13 .13 ] 5.3 41 ,200 [12 .08 ] 23 .0 [6.7] 36 ,700 [10.76 ] 4 .7 38 ,200 [11 .20 ] 18 .2 [5.3] 29 ,000 [8.50] 4 .0
TT-049 HFC-410A 48,400 [14 .19] 15 .7 [4.6] 59 ,900 [4.19 ] 5.2 54 ,600 [16 .00 ] 22 .5 [6.6] 48 ,300 [14.16 ] 4 .7 50 ,600 [14 .83 ] 17 .9 [5.2] 37,500 [10.99] 4 .0
TT-064 HFC-410A 61,500 [18 .03] 15 .0 [4.4] 72 ,300 [21 .19 ] 5.0 68 ,600 [20 .11 ] 22 .0 [6.4] 59 ,600 [17.47 ] 4 .4 64 ,800 [18 .99 ] 17 .5 [5.1] 48,000 [14.07] 3 .9
TT-072 HFC-410A 68,700 [20 .14] 14 .2 [4.2] 88 ,600 [25 .97 ] 4.9 77 ,100 [22 .60 ] 19 .9 [5.8] 70 ,200 [20.57 ] 4 .3 71 ,600 [20 .99 ] 16 .2 [4.7] 54,100 [15.86] 3 .6
performanCe and SpeCifiCaTionS
Full Load AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.All ratings based upon operation at the lower voltage of dual voltage rated models.
Dimensional DataVerticalUpflowModel
Overall Cabinet
W D H
026in.
cm
22.4
56.8
25.6
65.1
48.5
123.2
038in.
cm
25.4
64.5
30.6
77.8
50.5
128.3
049in.
cm
25.4
64.5
30.6
77.8
54.5
138.4
064in.
cm
25.4
64.5
30.6
77.8
58.5
148.6
072in.
cm
25.4
64.5
30.6
77.8
58.5
148.6
HorizontalModel
Overall Cabinet
W D H
026in.
cm
22.4
56.8
62.2
158.0
19.3
48.9
038in.
cm
25.4
64.5
71.2
180.8
21.3
54.0
049in.
cm
25.4
64.5
76.2
193.5
21.3
54.0
064in.
cm
25.4
64.5
81.2
206.2
21.3
54.0
072in.
cm
25.4
64.5
81.2
206.2
21.3
54.0
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TT-026 HFC-410A 19,400 [5.69] 18.3 [5.4] 22,400 [6.57] 6.1 22,200 [6.51] 30.8 [9.0] 18,600 [5.45] 5.1 21,300 [6.24] 26.0 [7.6] 16,500 [4.83] 4.6
TT-038 HFC-410A 26,200 [7.68] 18.5 [5.4] 30,800 [9.03] 6.3 30,200 [8.85] 31.5 [9.2] 24,800 [7.27] 5.1 28,900 [8.47] 27.0 [7.9] 22,100 [6.48] 4.5
TT-049 HFC-410A 36,100 [10 .58] 18 .0 [5.3] 44 ,300 [12 .98 ] 6.2 40 ,700 [11 .93 ] 28 .7 [8.4] 35 ,400 [10.38 ] 5 .1 39 ,600 [11 .61 ] 24 .9 [7.3] 31 ,200 [9.14] 4 .6
TT-064 HFC-410A 44,900 [13 .16] 17 .6 [5.2] 51 ,100 [14 .98 ] 5.7 51 ,900 [15 .21 ] 29 .7 [8.7] 49 ,800 [12.25 ] 4 .7 49 ,800 [14 .60 ] 25 .3 [7.4] 37,500 [10.99] 4 .3
TT-072 HFC-410A 52,800 [15 .48] 16 .0 [4.7] 65 ,200 [19 .11 ] 5.1 59 ,800 [17 .53 ] 24 .5 [7.2] 51 ,700 [15.15 ] 4 .3 57 ,700 [16 .91 ] 21 .4 [6.3] 45,400 [13.31] 3 .9
Part Load AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Note: Add 4 [10.16cm] to height forvertical downflow models.
Voltage OptionsModel Volts Hz Phase
026 208/230 60 1
038 - 064208/230208/230
460
606060
133
072 208/230 60 1
7/22/2019 Climate Master Com Proj LC007
23/48
22
The Tranquility 20 Single-Stage (TS) Series buildson ClimateMasters commitment to utilizing the mostadvanced technology and design to create oneof the most efficient single-stage water-source heatpump available today. The Tranquility 20 Single-Stage Series combines EarthPure(HFC-410A)refrigerant with the Copeland Scroll compressor(rotary in 018 and smaller) and either an ECM
variable speed or PSC multi-speed fan motor tocreate unmatched performance and flexibility.
uniT feaTureS
Sizes 006 (1/2 ton, 1.8 kW) through 070 (6 ton,21.1 kW)
Environmentally-friendly EarthPure(HFC-410A) refrigerant
Unsurpassed efficiencies (far exceeds ASHRAE 90.1) Copeland Scroll compressor (size 018 and above) Multi-speed PSC fan motor (optional variable
speed ECM motor on size 018 and above)
Galvanized steel construction and powder coatpaint on all units
Unique double isolation compressor mounting forquiet operation
Discharge muffler standard (except rotarycompressors) for superior sound attenuation
Microprocessor controls standard (optional DXMand/or DDC controls)
Field convertible discharge air arrangement forhorizontal units Bi-directional, balanced port expansion valve
refrigerant metering device standard Standard range or extended range operation Water connections securely mounted flush to the
cabinet corner post (no backup wrench required) Eight safeties standard
THe TranquiliTy 20 Single-STage (TS) SerieS
Easy to remove blowerhousing for quick serviceand optional ECMvariable speed motor
Foil faced insulation inthe blower section andfiberglass insulation inthe compressor section
Dual compressorvibration isolation forquiet operation
Easy service access frommultiple sides
Easy access controlbox contains advanceddigital controls withRemote Service Sentinel(Optional Enhancedcontrols (DXM) & DDCControllers)
Factory installedhanger brackets onhorizontal units
Standard stainless steelinsulated drain pan withcondensate overflowprotection
7/22/2019 Climate Master Com Proj LC007
24/48
23
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Dimensional Data
Model* Ref rigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacit y EER Capacit y
COP
Capacity E ER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TS-006 PSC HFC-410A 6,300 [1.85] 15.7 [4.6] 8,000 [2.34] 5.4 7,400 [2.17] 25.5 [7.5] 6,300 [1.85] 4.4 6,700 [1.96] 18.5 [5.4] 4,800 [1.41] 3.4
TS-009 PSC HFC-410A 9,300 [2.74] 15.3 [4.5] 11,100 [3.26] 4.8 11,100 [3.26] 25.2 [7.4] 9,400 [2.76] 4.3 10,000 [2.94] 18.1 [5.3] 7100 [2.09] 3.4
TS-012 PSC HFC-410A 11,700 [3.43] 15.4 [4.5] 13,800 [4.05] 4.5 13,300 [3.90] 24.6 [7.2] 11,800 [3.46] 4.0 12,300 [3.60] 18.1 [5.3] 9,500 [2.78] 3.5
TS-018 PSCTS-018 ECM
HFC-410A18,600 [5.47]
19,200 [5.65]
15.0 [4.4]
16.5 [4.8]
23,000 [6.76]
23,300 [6.85]
5.2
5.9
21,300 [6.26]
22,100 [6.50]
24.8 [7.3]
26.3 [7.7]
18,800 [5.53]
18,900 [5.56]
4.5
4.9
19,500 [5.74]
20,200 [5.94]
18.4 [5.4]
19.4 [5.5]
14,500 [4.27]
14,500 [4.43]
3.6
3.9
TS-024 PSCTS-024 ECM
HFC-410A25,100 [7.36]
25,000 [7.33]
16.2 [4.8]
17.0 [5.0
29,600 [8.68]
30,000 [8.79]
4.9
5.3
28,600 [8.38]
28,100 [8.24]
25.7 [7.5]
27.4 [8.0]
25,000 [7.33]
25,100 [7.36]
4.3
4.6
26,300 [7.71]
26,000 [7.62]
19.1 [5.6]
20.0 [5.0]
19,000 [5.57]
19,400 [5.69]
3.7
3.8
TS-030 PSCTS-030 ECM
HFC-410A28,200 [8.26]
28,600 [8.38]
15.3 [4.5]
15.6 [4.6]
34,900 [10.23]
35,200 [10.32]
5.0
5.3
31,700 [9.29]
32,200 [9.44]
22.9 [6.7]
23.9 [7.0]
29,400 [8.62]
29,400 [8.62]
4.4
4.6
29,400 [8.62]
29,800 [8.73]
17.6 [5.2]
18.0 [5.3]
23,600 [6.92]
23,700 [6.95]
3.8
3.9
TS-036 PSCTS-036 ECM
HFC-410A33,000 [9.67]
33,100 [9.70]
16.6 [4.9]
17.6 [5.2]
39,800 [11.66]
39,500 [11.58]
5.5
5.8
37,300 [10.93]
37,300 [10.93]
25.1 [7.4]
26.5 [7.8]
32,900 [9.64]
32,900 [9.64]
4.8
5.1
34,500 [10.11]
34,600 [10.14]
19.2 [5.6]
20.2 [5.9]
25,700 [7.53]
25,800 [7.56]
3.9
4.2
TS-042 PSCTS-042 ECM
HFC-410A37,400 [10.96]
37,800 [11.08]
16.0 [4.7]
17.1 [5.0]
49,400 [14.48]
48,600 [14.24]
5.4
5.7
42,900 [12.57]
44,200 [12.95]
24.3 [7.1]
27.1 [7.9]
40,100 [11.75]
39,300 [11.52]
4.6
4.9
39,300 [11.52]
40,000 [11.72]
18.4 [5.4]
20.0 [5.9]
31,600 [9.26]
30,400 [8.91]
3.8
4.0
TS-048 PSCTS-048 ECM
HFC-410A47,000 [13.77]
47,600 [13.95]
15.3 [4.5]
15.9 [4.7]
60,000 [17.58]
59,700 [17.50]
5.0
5.2
53,900 [15.80]
54,100 [15.86]
23.3 [6.8]
24.6 [7.2]
49,000 [14.36]
48,700 [14.27]
4.4
4.5
49,900 [14.62]
50,100 [14.68]
17.6 [5.2]
18.5 [5.4]
39,000 [11.43]
38,400 [11.25]
3.7
3.8
TS-060 PSCTS-060 ECM
HFC-410A61,000 [17.88]
62,000 [17.88]
15.9 [4.7]
16.4 [4.8]
70,400 [20.63]
70,800 [20.75]
5.0
5.2
67,000 [19.64]
67,200 [19.70]
23.2 [6.8]
24.3 [7.1]
58,700 [17.20]
59,100 [17.32]
4.5
4.6
63,300 [18.55]
64,000 [18.76]
18.2 [5.3]
19.0 [5.6]
46,500 [13.63]
46,700 [13.69]
3.7
3.8
TS-070 PSCTS-070 ECM
HFC-410A67,500 [19.78]
67,000 [19.64]
14.4 [4.2]
15.2 [4.5]
85,800 [25.15]
84,900 [24.88]
5.0
5.0
77,100 [22.60]
77,000 [22.57]
21.6 [6.3]
23.5 [6.9]
69,400 [20.34]
69,000 [20.22]
4.3
4.4
70,800 [20.75]
70,000 [20.52]
16.6 [4.9]
17.8 [5.2]
54,000 [15.83]
53,900 [15.80]
3.6
3.6
VerticalUpflowModel
Overall Cabinet
W D H
006 -012
in.
cm
22.4
56.8
21.6
54.9
34.5
87.6
018in.
cm
22.4
56.8
25.6
65.1
44.5
113.0
024 -030
in.
cm
22.4
56.8
25.6
65.1
48.5
123.2
036in.
cm
25.4
64.5
30.6
77.8
50.5
128.3
042-048
in.
cm
25.4
64.5
30.6
77.8
54.5
138.4
060 -070
in.cm
25.464.5
30.677.8
58.5148.6
HorizontalModel
Overall Cabinet
W D H
006 -012
in.
cm
22.4
56.8
43.1
109.5
17.3
43.9
018 -030
in.
cm
22.4
56.8
62.2
158.0
19.3
49.0
036in.
cm
25.4
64.5
71.2
180.8
21.3
54.1
042 -048
in.
cm
25.4
64.5
76.2
193.5
21.3
54.1
060 -070
in.
cm
25.4
64.5
81.2
206.2
21.3
54.1
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.All ratings based upon operation at the lower voltage of dual voltage rated models.* ECM motor available on sizes 018 and larger.
Note: Add 4 [10.16cm] to height for vertical downflow models.
Voltage OptionsModel Volts Hz Phase
06 - 018208/230
265
60
60
1
1
024 -036
208/230
265
208/230
460
60
60
60
60
1
1
3
3
042 -070
208/230
208/230
460
575
60
60
60
60
1
3
3
3
7/22/2019 Climate Master Com Proj LC007
25/48
24
The Tranquility High Efficiency (TR) Series offers highefficient performance in a simple cabinet design.
The Tranquility High Efficiency Series also offersoptions that allow for application flexibility. Availableoptions include ClimaDry dehumidification, hotwater generator, enhanced controls, e-coatedair coils, extended range insulation, UltraQuiet
package, secondary circulating pump, motorizedwater valve, automatic water flow valves and highstatic blowers.
uniT feaTureS
Sizes 006 (1/2 ton, 1.8 kW) through 060(5 tons, 17.6 kW)
Exceeds ASHRAE 90.1 efficiencies Galvanized steel construction with attractive matte
black epoxy powder coat paint front access panel Epoxy powder painted galvanized steel drain pan
Sound absorbing glass fiber insulation Unique double isolation compressor mounting for
quiet operation Insulated divider and separate compressor/air
handler compartments Copeland scroll compressors (Size 018 and
above) Microprocessor controls standard (optional DXM
and/or DDC controls) Field convertible discharge air arrangement forhorizontal units
PSC three-speed fan motor Internally trapped condensate drain line (vertical
units only) Eight safeties standard Extended range (20 to 120F, -6.7 to 48.9C)
capable
THe TranquiliTy HigH effiCienCy (Tr) SerieS
Dual compressor vibrationisolation for quiet operation
Easy access control boxcontains advanced digitalcontrols with Remote ServiceSentinel Optional Enhancedcontrols (DXM) & DDCControllers
Epoxy powder painteddrain pan with condensateoverflow protection
Factory installed hangerbrackets on horizontal units
Easy to remove blowerhousing for quick service andPSC three-speed fan motor
Easy service access
from multiple sides
7/22/2019 Climate Master Com Proj LC007
26/48
25
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TR-006 HFC-410A 5,800 [1.70] 13.2 [3.9] 7,500 [2.20] 4.7 6,900 [2.02] 21.1 [6.2] 6,200 [1.82] 4.0 6,200 [1.82] 15.4 [4.5] 4,900 [1.44] 3.4
TR-009 HFC-410A 8,800 [2.58] 13.4 [3.9] 11,600 [3.40] 4.2 10,100 [2.96] 21.0 [6.2] 9,800 [2.87] 3.9 9,300 [2.72] 15.7 [4.6] 7,900 [2.31] 3.4
TR-012 HFC-410A 11,700 [3.43] 13.5 [4.0] 15,200 [4.45] 4.3 13,700 [4.01] 20.8 [6.1] 12,500 [3.66] 3.8 12,000 [3.52] 14.9 [4.4] 9,900 [2.90] 3.2
TR-015 HFC-410A 14,500 [4.25] 15.4 [4.5] 17,300 [5.07] 5.0 16,800 [4.92] 24.5 [7.2] 14,400 [4.22] 4.4 15,000 [4.39] 17.2 [5.0] 11,100 [3.25] 3.6
TR-018 HFC-410A 17,300 [5.07] 14.3 [4.2] 21,500 [6.30] 5.0 20,600 [6.04] 24.2 [7.1] 17,200 [5.04] 4.4 18,400 [5.39] 16.3 [4.8] 13,900 [4.07] 3.4
TR-024 HFC-410A 23,700 [6.94] 13.4 [3.9] 28,500 [8.35] 4.7 26,700 [7.82] 20.9 [6.1] 24,000 [7.03] 4.1 24,900 [7.30] 15.4 [4.5] 18,500 [5.42] 3.3
TR-030 HFC-410A 28,100 [8.23] 13.4 [3.9] 35,100 [10.28] 4.6 31,700 [9.29] 20.1 [5.9] 29,600 [8.67] 4.1 28,900 [8.47] 15.1 [4.4] 23,400 [6.86] 3.4
TR-036 HFC-410A 34,500 [10.11] 13.5 [4.0] 45,200 [13.24] 4.4 38,700 [11.34] 20.7 [6.1] 37,500 [10.99] 4.0 35,300 [10.34] 14.9 [4.4] 29,600 [8.67] 3.3
TR-042 HFC-410A 40,100 [11.75] 13.1 [3.8] 52,700 [15.44] 4.3 45,900 [13.45] 19.6 [5.7] 44,000 [12.89] 3.8 40,500 [11.87] 14.4 [4.2] 34,300 [10.05] 3.2
TR-048 HFC-410A 47,700 [13.98] 13.3 [3.9] 55,900 [16.38] 4.7 54,300 [15.91] 20.5 [6.0] 46,500 [13.62] 4.1 49,000 [14.36] 14.7 [4.3] 36,400 [10.67] 3.4
TR-060 HFC-410A 59,400 [17.40] 13.4 [3.9] 77,000 [22.58] 4.3 66,600 [19.51] 19.9 [5.8] 64,000 [18.75] 3.8 60,100 [17.61] 14.8 [4.3] 50,500 [14.80] 3.1
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.All ratings based upon operation at the lower voltage of dual voltage rated models.
Dimensional Data
Vertical UpflowModel
Overall Cabinet
W D H
006 - 012 in.cm
22.557.2
21.354.1
22.557.2
015 - 030in.
cm
22.4
56.9
22.4
56.9
40.5
102.9
036 - 042in.
cm
22.4
56.9
25.4
64.5
46.5
118.1
048 - 060in.
cm
25.4
64.5
29.1
73.9
50.5
128.3
HorizontalModel
Overall Cabinet
W D H
006 - 012 in.cm
22.557.2
40.3102.4
11.529.2
015 - 030in.
cm
22.4
56.9
48.3
122.7
17.5
44.5
036 - 042in.
cm
22.4
56.9
53.1
134.9
21.3
54.1
048 - 060in.
cm
25.4
64.5
67.9
172.5
21.3
54.1
Voltage Options
Model Volts Hz Phase
006 - 024208/230
265
60
60
1
1
030 - 036
208/230
265
208/230
460
60
60
60
60
1
1
3
3
042 - 060
208/230
208/230
460
575
60
60
60
60
1
3
3
3
26 6 ( )
7/22/2019 Climate Master Com Proj LC007
27/48
26
The Tranquility 16 Compact (TC) Series raisesthe bar for water-source heat pump efficiencies,features and application flexibility. Not only does theTranquility 16 Compact Series exceed ASHRAE 90.1efficiencies, but it also uses EarthPure(HFC-410A)zero ozone depletion refrigerant, making itan extremely environmentally-friendly option.
With one of the smallest cabinets in the industry, theTranquility 16 Compact (TC) Series will easily fit intotight spaces. Designed to be backward compatiblewith thousands of older water-source heat pumps,the Tranquility 16 Compact (TC) Series heat pumpis packed full of the innovation you have come toexpect from the experts at ClimateMaster.
uniT feaTureS
Sizes 006 (1/2 ton, 1.8 kW) through 060 (5 tons,17.6 kW)
EarthPure(HFC-410A) refrigerant
Exceeds ASHRAE 90.1 efficiencies Galvanized steel construction with attractive matte
black epoxy powder coat paint front access panel Epoxy powder painted galvanized steel drain pan Sound absorbing glass fiber insulation Unique double isolation compressor mounting for
quiet operation Insulated divider and separate compressor/air
handler compartments Copeland scroll compressors (size 018 and above) TXV metering device Microprocessor controls standard (optional DXM
and/or DDC controls) Field convertible discharge air arrangement for
horizontal units
THe TranquiliTy 16 CompaCT (TC) SerieS
Dual compressor vibrationisolation for quiet operation
Easy access control boxcontains advanced digitalcontrols with Remote ServiceSentinel Optional Enhancedcontrols (DXM) & DDCControllers
Epoxy powder painteddrain pan with condensateoverflow protection
Factory installed hangerbrackets on horizontal units
Easy to remove blowerhousing for quick service andPSC three-speed fan motor
Easy service access from
multiple sides
27
7/22/2019 Climate Master Com Proj LC007
28/48
27
performanCe and SpeCifiCaTionS
Dimensional Data Voltage Options
Model Volts Hz Phase
006 - 024208/230
26560 1
030 - 036
208/230
265
208/230
460
60
60
60
60
1
1
3
3
042 - 060
208/230
208/230
460
575
60
60
60
60
1
3
3
3
HorizontalModel
Overall Cabinet
Width Length Height
006 - 012
in.
cm
19.1
48.5
34.1
86.6
11.1
28.2
015 - 018 in.
cm
20.1
51.1
43.1
109.5
17.0
43.2
024 - 030 in.
cm
20.1
51.1
43.1
109.5
18.3
46.5
036 - 042 in.
cm
20.1
51.1
47.1
119.6
21.0
53.3
048 - 060 in.
cm
24.1
61.2
54.1
137.4
21.0
53.3
072 - 120 in.
cm
36.3
92.2
84.9
215.6
21.0
54.9
VerticalUplflowModel
Overall Cabinet
Width Dep th Height
006 - 012 in.cm
19.148.5
19.148.5
22.055.9
015 - 018 in.
cm
21.5
54.6
21.5
54.6
40.0
101.6
024 - 030 in.
cm
21.5
54.6
21.5
54.6
45.0
114.3
036 - 042 in.
cm
21.5
54.6
26.0
66.0
44.0
111.8
048 - 060 in.
cm
24.0
61.0
29.1
73.9
50.5
128.3
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TC-006 HFC-410A 5,800 [1.70] 13.2 [3.9] 7,500 [2.20] 4.7 6,900 [2.02] 21.1 [6.2] 6,200 [1.82] 4.0 6,200 [1.82] 15.4 [4.5] 4,900 [1.44] 3.4
TC-009 HFC-410A 8,800 [2.58] 13.4 [3.9] 11,600 [3.40] 4.2 10,100 [2.96] 21.0 [6.2] 9,800 [2.87] 3.9 9,300 [2.72] 15.7 [4.6] 7,900 [2.31] 3.4
TC-012 HFC-410A 11,700 [3.43] 13.5 [4.0] 15,200 [4.45] 4.3 13,700 [4.01] 20.8 [6.1] 12,500 [3.66] 3.8 12,000 [3.52] 14.9 [4.4] 9,900 [2.90] 3.2
TC-015 HFC-410A 14,500 [4.25] 15.4 [4.5] 17,300 [5.07] 5.0 16,800 [4.92] 24.5 [7.2] 14,400 [4.22] 4.4 15,000 [4.39] 17.2 [5.0] 11,100 [3.25] 3.6
TC-018 HFC-410A 17,300 [5.07] 14.3 [4.2] 21,500 [6.30] 5.0 20,600 [6.04] 24.2 [7.1] 17,200 [5.04] 4.4 18,400 [5.39] 16.3 [4.8] 13,900 [4.07] 3.4
TC-024 HFC-410A 23,700 [6.94] 13.4 [3.9] 28,500 [8.35] 4.7 26,700 [7.82] 20.9 [6.1] 24,000 [7.03] 4.1 24,900 [7.30] 15.4 [4.5] 18,500 [5.42] 3.3
TC-030 HFC-410A 28,100 [8.23] 13.4 [3.9] 35,100 [10.28] 4.6 31,700 [9.29] 20.1 [5.9] 29,600 [8.67] 4.1 28,900 [8.47] 15.1 [4.4] 23,400 [6.86] 3.4
TC-036 HFC-410A 34,500 [10.11] 13.5 [4.0] 45,200 [13.24] 4.4 38,700 [11.34] 20.7 [6.1] 37,500 [10.99] 4.0 35,300 [10.34] 14.9 [4.4] 29,600 [8.67] 3.3
TC-042 HFC-410A 40,100 [11.75] 13.1 [3.8] 52,700 [15.44] 4.3 45,900 [13.45] 19.6 [5.7] 44,000 [12.89] 3.8 40,500 [11.87] 14.4 [4.2] 34,300 [10.05] 3.2
TC-048 HFC-410A 47,700 [13.98] 13.3 [3.9] 55,900 [16.38] 4.7 54,300 [15.91] 20.5 [6.0] 46,500 [13.62] 4.1 49,000 [14.36] 14.7 [4.3] 36,400 [10.67] 3.4
TC-060 HFC-410A 59,400 [17.40] 13.4 [3.9] 77,000 [22.58] 4.3 66,600 [19.51] 19.9 [5.8] 64,000 [18.75] 3.8 60,100 [17.61] 14.8 [4.3] 50,500 [14.80] 3.1
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.All ratings based upon operation at the lower voltage of dual voltage rated models.
28 TranquiliTy VerTiCal STaCk (Trm) SerieS
7/22/2019 Climate Master Com Proj LC007
29/48
28
Installed System
The Tranquility Vertical Stack (TRM) Series offers aninnovative, labor-saving solution for spaces whereindividual, quiet control of the heating and coolingsystem is important. Using EarthPure(HFC-410A)refrigerant, the Tranquility Vertical Stack (TRM)Series not only protects the environment, it does so
while delivering unprecedented comfort, efficiency,and reliability.
uniT feaTureS
Sizes 09 (3/4 ton, 2.6 kW) through 36 (3 ton,10.6 kW)
Environmentally-friendly EarthPure(HFC-410A)zero ozone depletion refrigerant
High efficiency rotary and scroll compressors Exceeds ASHRAE 90.1 efficiencies
Removable chassis allows staged installation andease of maintenance Galvanized steel cabinet Unique double isolation compressor mounting for
quiet operation TXV metering device Unit or remote-mounted controls available Microprocessor controls standard (optional DXM
and/or DDC controls) LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls
Unit Performance Sentinel performancemonitoring system Attractive return air panel with hinged access door
(G panel) Multiple supply air discharge options Stainless steel braided hose kits for connection
from piping risers to chassis Eight safeties standard Wide variety of options including disconnect
switch and extended range
TranquiliTy VerTiCal STaCk (Trm) SerieS
Exclusive dual-levelcompressor isolationlowers vibration andreduces noise for quietoperation
Removable chassis allowsstaged installation andease of maintenance/
service once installation iscomplete
Advanced digital controlswith Remote ServiceSentinel. Shown withoptional DDC Controller(Optional Enhancedcontrols (DXM) alsoavailable)
Integrated Drain Pan withcondensate overflowprotection (OptionalStainless Steel Drain Pan)
Torsion-flex blower motorsTRM09-12
29
7/22/2019 Climate Master Com Proj LC007
30/48
29
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86F [30C] Heating 68F [20C] Cooling 59F [15C] Heating 60F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TRM-09 HFC-410A 8,800 [2.58] 13.0 [3.8] 12,500 [3.66] 4.6 10,100 [2.93] 19.5 [5.7] 9,800 [2.87] 3.8 9,300 [2.73] 14.7 [4.3] 7,200 [2.11] 3.1
TRM-12 HFC-410A 11,600 [3.40] 13.0 [3.8] 15,800 [4.63] 4.5 13,700 [4.02] 20.0 [5.9] 12,700 [3.72] 3.8 12,200 [3.58] 15.0 [4.4] 9,500 [2.78] 3.1
TRM-15 HFC-410A 13,800 [4.05] 13.0 [3.8] 19,600 [5.74] 4.7 16,500 [4.84] 20.0 [5.9] 15,500 [4.54] 3.9 15,200 [4.46] 14.6 [4.3] 11,500 [3.37] 3.1
TRM-18 HFC-410A 16,700 [4.89] 13.0 [3.8] 22,600 [6.62] 4.7 19,600 [5.74] 19.5 [5.7] 18,200 [5.33] 3.8 17,600 [5.16] 14.6 [4.3] 14,000 [4.10] 3.1
TRM-24 HFC-410A 22,100 [6.48] 13.0 [3.8] 29,400 [8.62] 4.5 26,400 [7.74] 20.0 [5.9] 23,100 [6.77] 3.8 23,600 [6.92] 14.8 [4.3] 18,000 [5.28] 3.1
TRM-30 HFC-410A 27,100 [7.94] 13.0 [3.8] 33,100 [9.70] 4.6 30,600 [8.97] 18.6 [5.5] 27,700 [8.12] 4.0 29,200 [8.56] 16.0 [4.7] 20,600 [6.04] 3.1
TRM-36 HFC-410A 32,000 [9.38] 12.5 [3.7] 39,500 [11.58] 4.6 36,700 [10.76] 18.8 [5.5] 32,000 [9.38] 3.8 33,000 [9.67] 14.3 [4.2] 25,000 [7.33] 3.1
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.
All ratings based upon operation at the lower voltage of dual voltage rated models.
* Not including risers or flanges.** 80 [203.2cm] also standard.
ModelOverall Cabinet*
W D H **
09 - 12in.
cm
17.0
43.2
17.0
43.2
88.0
223.5
15 - 18in.
cm
20.0
50.8
20.0
50.8
88.0
223.5
24 - 36in.
cm
24.0
61.0
24.0
61.0
88.0
223.5
Model Volts Hz Phase
09 - 36208/230
265
60
60
1
1
Dimensional Data Voltage Options
30 TranquiliTy ConSole (TrC) SerieS
7/22/2019 Climate Master Com Proj LC007
31/48
30
The Tranquility Console (TRC) Series provides ahigh efficiency WSHP ductless solution for spaceswhere individual, quiet control of the heating andcooling system is important. Tranquility ConsoleSeries units are especially ideal where ceilingheight and space are limited, or when preservingthe integrity of an existing structure. The TranquilityConsole Series exceeds ASHRAE 90.1 efficiencies,yet maintains small cabinet dimensions. UsingEarthPure(HFC-410A) refrigerant, the TranquilityConsole Series not only protects the environment,it does so while delivering unprecedented comfort,efficiency, and reliability.
uniT feaTureS
Sizes 09 (3/4 ton, 2.6 kW) through 18 (1-1/2ton, 5.3 kW)
Environmentally-friendly EarthPure(HFC-410A)zero ozone depletion refrigerant
Two-piece chassis/cabinet design
Slope top with aluminum rigid bar supply air grilleand aluminum control door
TXV metering device Extended range (20 to 120F, -6.7 to 48.9C)
operation Advanced digital auto or manual change-over
unit mounted control with temperature display,speed selection and fault indication
Remote-mounted control available Microprocessor controls standard (optional DXM
and/or DDC controls) LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls Right or left-hand piping arrangement Front or bottom return air Unit Performance Sentinel performance
monitoring system Eight safeties standard Wide variety of options including e-coated air
coils and UltraQuiet construction
TranquiliTy ConSole (TrC) SerieS
Optional motorized damperfor outside air intake forimproved air quality
Optional insulated
water circuit for extendedrange applications
Advanced digital controlswith Remote ServiceSentinel. (OptionalEnhanced controls (DXM)& DDC Controllers)
Unit mounted digitalcontrol available inmanual and autochangeover
Shown with optionalreturn air grille
31
7/22/2019 Climate Master Com Proj LC007
32/48
31
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cool ing 86F [30C] Heat ing 68F [20C] Coo li ng 59F [15C] Heat ing 50F [10C ] Cool ing 77F [25C] Heat ing 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TRC-09 HFC-410A 8,600 [2.52] 13.3 [3.9] 11,400 [3.34] 4.6 9,200 [2.70] 18.6 [5.5] 9,500 [2.78] 4.0 8,800 [2.58] 14.9 [4.4] 7,300 [2.14] 3.3
TRC-12 HFC-410A 11,300 [3.31] 13.3 [3.9] 14,900 [4.37] 4.9 12,500 [3.66] 18.7 [5.5] 12,100 [3.55] 4.1 11,800 [3.46] 15.1 [4.4] 9,300 [2.73] 3.3
TRC-15 HFC-410A 14,100 [4.13] 13.5 [4.0] 18,200 [5.33] 5.1 16,600 [4.87] 21.3 [6.2] 14,800 [4.34] 4.3 15,100 [4.43] 15.8 [4.6] 11,400 [3.34] 3.5
TRC-18 HFC-410A 16,200 [4.57] 13.0 [3.8] 20,100 [5.89] 4.5 17,600 [5.16] 19.5 [5.7] 16,500 [4.84] 4.0 16,500 [4.84] 15.0 [4.4] 13,200 [3.87] 3.4
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.All ratings based upon operation at the lower voltage of dual voltage rated models.
Dimensional Data
ModelOverall Cabinet
W D H
5[12.7]
Subbase
in.
cm
48
121.9
12
30.5
26
66.0
NoSubbase
in.
cm
48
121.9
12
30.5
21
53.3
Model Volts Hz Phase
09-12115
208/230
265
60
60
60
1
1
1
15-18208/230
265
60
60
1
1
Voltage Options
Note: Add 6 [15.2cm] to width for size 18.
32 TranquiliTy CompaCT (TCH) SerieS
7/22/2019 Climate Master Com Proj LC007
33/48
q
Available in sizes 6 tons (21.1 kW) through 10 tons(35.2 kW) with multiple cabinet configurations,the Tranquility Compact (TCH) Series offers awide range of units for most any installation. TheTranquility Compact Series has an extendedrange refrigerant circuit, capable of groundloop (geothermal) applications (may requireoptional extended range insulation), ground water(geothermal) applications, as well as water loop(boiler-tower) applications. Standard features aremany. Microprocessor controls, galvanized steelcabinet, epoxy powder coat painted front accesspanel, galvanized steel with epoxy powder coatpainted drain pan and TXV refrigerant meteringdevice are just some of the features of the flexibleTranquility Compact Series.
uniT feaTureS
Horizontal sizes 072 (6 tons, 21.1 kW), 096 (8
tons, 28.1 kW), 120 (10 tons, 35.2 kW)
Unit configuration can be ordered with left orright return air and straight or back supply airdischarge. Discharge is field convertible. Fieldconversion uses all existing parts including panelsand belts
Electrical box is on right side and can be fieldconverted to left side of unit
Electric power can enter from either side of front Water can be connected to either side Copeland scroll compressors Dual refrigeration circuits (All Models) Exceeds ASHRAE 90.1 efficiencies Galvanized steel construction with attractive matte
black epoxy powder coat painted front accesspanel
Insulated divider and separate compressor/airhandler compartments
TXV metering device Extended range (20 to 120F, -6.7 to 48.9C)
operation (may require optional extended rangeinsulation)
Condensate overflow isone of the 8 standardsafeties provided by themicroprocessor controls inall TCH Series units
Dual compressorrefrigeration circuit
Large capacity (up to 10tons)
Belt drive blower with highefficiency motor and multiplepulley adjustments
Galvanized steel cabinet
Optional insulated water/refrigerant circuits allowextended range operation(ground loop applications)
33
7/22/2019 Climate Master Com Proj LC007
34/48
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (English (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27.02C] DB, 66.2F [19.02C] WB entering air temperature.Heating capacities based upon 68F [20.02C] DB, 59F [15.02C] WB entering air temperature.All ratings based upon operation at lower voltage of dual voltage rated models.
Dimensional Data
HorizontalModel
Overall CabinetW D H
072 - 120in.
cm
36.3
92.2
84.9
215.6
21.6
54.9
HorizontalModel
Volts Hz Phase
072 - 120208/230
460
575
60
60
60
3
3
3
Voltage Options
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Coo ling 86F [30C] Heat ing 68F [20C] Coo li ng 59F [15C ] Heat ing 50F [10C] Cool ing 77F [25C] Heati ng 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TCH-072 HFC-410A 69,000 [20.22] 13.3 [3.9] 92,500 [27.11] 5.0 78, 500 [23. 01] 19.7 [5. 8] 75,500 [22.13] 4.4 71,000 [20.80] 14.6 [4.3] 58, 000 [17. 00] 3.5
TCH-096 HFC-410A 95,000 [27.84] 13.7 [4.0] 123, 000 [36. 04] 5.0 104,500 [30.63] 20.0 [5. 9] 101, 000 [29. 60] 4.4 98,000 [28.72] 15.2 [4.5] 77, 000 [22. 57] 3.6
TCH-120 HFC-410A 1 19 ,0 00 [ 34 .8 8] 13 .3 [ 3.9] 16 0,00 0 [4 6.89 ] 4 .6 1 34 ,0 00 [ 39 .2 7] 19 .3 [ 5.7] 13 2,50 0 [3 8.83 ] 4 .0 1 22 ,5 00 [ 35.90 ] 1 4.5 [4 .2 ] 1 03 ,0 00 [ 30 .1 9] 3 .3
34 TranquiliTy large (Tl) SerieS
7/22/2019 Climate Master Com Proj LC007
35/48
The award winning Tranquility Large (TL) Seriesraises the bar for water-source heat pumpefficiencies, features and application flexibility.Not only does the Tranquility Large Seriesexceed ASHRAE 90.1 efficiencies, but it also usesEarthPure(HFC-410A) zero ozone depletionrefrigerant, making it an extremely environmentally-friendly option. Tranquility Large Series is eligiblefor additional LEED(Leadership in Energy andEnvironmental Design) points because of the greentechnology design.
uniT feaTureS
Vertical sizes 084 (7 tons, 24.6 kW) through 300(25 tons, 87.9 kW)
Unit configuration can be ordered with, orconverted to front or back return and top, front, orback discharge. Field conversion uses all existingparts including panels and belts
Electrical box can be field converted to be onfront or back of unit
Electric power can enter from any side of unit Water and drain can be connected to either side Dual refrigeration circuits (TL168, 192, 240, 300) Exceeds ASHRAE 90.1 efficiencies TXV metering device Extended range (20 to 120F, -6.7 to 48.9C
operation) Microprocessor controls standard (optional DXM
and/or DDC controls) LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls Unit Performance Sentinel performance
monitoring system
Condensate overflow isone of the 8 standardsafeties provided by themicroprocessor controls in allTL Series units
Dual compressor refrigeration circuit in TL 168-300equipment single compressor refrigeration circuit inTL 084-150
Optional insulated water/refrigerant circuits allowextended range operation(ground loop applications)
Belt drive blowers withhigh efficiency motors andmultiple pulley adjustments
Wide variety of verticalconfigurations
Large capacity (up to 25tons, 87.97 kW)
Galvanized steel cabinetwith baked-on epoxy powderfinish on all access panels
35
7/22/2019 Climate Master Com Proj LC007
36/48
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-1 Data (Engish (IP) Units & Metric (SI) Units)
Cooling capacities based upon 80.6F [27C] DB, 66.2F [19C] WB entering air temperature.
Heating capacities based upon 68F [20C] DB, 59F [15C] WB entering air temperature.All ratings based upon operation at the lower voltage of dual voltage rated models.
Dimensional Data
VerticalModel
Overall Cabinet
W D H
084-150
in.
cm
53.1
134.9
34.0
86.4
79.0
200.7
168-300
in.
cm
106.7
270.9
34.0
86.4
79.0
200.7
VerticalModel
Volts Hz Phase
084 - 300
208/230460575
380/420
60606060
3333
Voltage Options
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Coolin g 86F [30C] Heat in g 68F [20C] Cooling 59F [ 15C] Heat ing 50F [10C] Cooling 77F [25C] Heating 32F [0C]
Capacity EER Capacity
COP
Capacity EER Capacity
COP
Capacity EER Capacity
COPBtuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
Btuh[kW]
Btuh/W[W/W]
Btuh[kW]
TLV-084 HFC-410A 82,000 [24.03] 15.2 [4.5] 101,000 [29.60] 4.8 87,500 [25.65] 21.0 [4.3] 83,500 [24.33] 4.3 83,000 [24.33] 16.5 [4.8] 65,500 [19.20] 3.6
TLV-096 HFC-410A 94,000 [27.55] 15. 0 [4.4] 118,000 [34.58] 4.7 102,500 [30.04] 20.5 [4.2] 96,500 [28.58] 4.2 97,500 [28.58] 16.5 [4. 8] 76,500 [22.42] 3.6
TLV-120 HFC-410A 118,000 [34.58] 15. 0 [4.4] 144,000 [42.20] 5.0 133,000 [38.98] 21.0 [4.2] 118, 000 [34. 58] 4.2 120, 000 [35. 17] 16.5 [4.8] 93,000 [27.26] 3.7
TLV-150 HFC-410A 150,000 [43.96] 14. 0 [4.1] 186,000 [54.51] 4.7 170,000 [49. 82] 20.0 [4.2] 155, 000 [45. 43] 4.2 156, 000 [45. 72] 15. 8 [4.6] 122, 000 [35.76] 3.6
TLV-168 HFC-410A 166,000 [48.65] 15.5 [4.5] 204,020 [59.80] 4.9 177, 000 [51. 87] 21.4 [4.4] 169, 000 [49. 53] 4.4 168, 000 [49. 24] 16. 8 [4.9] 132, 500 [38.83] 3.7
TLV-192 HFC-410A 190,000 [55.69] 15.3 [4.5] 238,360 [69.86] 4.8 207, 000 [60. 67] 20.9 [4.3] 195, 000 [57. 15] 4.3 197, 000 [57. 74] 16. 8 [4.9] 155,000 [45.43] 3.7
TLV-240 HFC-410A 238,500 [69.90] 15.3 [4.5] 291,000 [85.29] 5.1 269, 000 [78. 84] 21.4 [4.3] 238, 000 [69.90] 4. 3 242, 500 [71. 07] 16. 8 [4.9] 188,000 [55.10] 3. 8
TLV-300 HFC-410A 300,000 [87.93] 14.0 [4.1] 372,000 [109.03] 4.7 340, 000 [99. 65] 20.0 [4.2] 310, 000 [90.86] 4. 2 312, 000 [91. 44] 15. 8 [4.6] 244,000 [71.51] 3. 6
36 TranquiliTy modular waTer-To-waTer (Tmw) SerieS
7/22/2019 Climate Master Com Proj LC007
37/48
The Tranquility Modular Water-to-Water (TMW)Series offers high efficiency and high capacity withadvanced features, quiet operation and applicationflexibility at competitive prices. ClimateMastersTranquility Modular Water-to-Water Series can beused for radiant floor heating, snow/ice melt, chilledwater for fan coils, industrial process control, potablehot water generation*, hot/chilled water for make-up air, and many other types of HVAC and industrial
applications that require cost effective heated orchilled water.
uniT feaTureS
Sizes 036 (3 tons, 10.6 kW) through 340(28 tons, 100 kW)
Copeland scroll compressor(s) Dual independent refrigeration circuits on size
120 and 340 (28 tons, 100 kW) Exclusive single side service access (front of unit)
allows multiple units to be installed side-by-side for
large capacity installations
Top water connections on sizes 170 (14 tons, 50kW) and 340 (28 tons, 100 kW), staggered forease of manifolding multiple units
Exceeds ASHRAE 90.1 efficiencies Heavy gauge galvanized steel construction with
polyester powder coat paint and stainless steelfront access panels
Insulated compressor compartment Small footprint
TXV metering devices Extended range (20 to 110F, -6.7 to 43.3C)
operation Microprocessor controls standard (optional DXM
and/or DDC controls) LonWorks, BACnet, Modbus and Johnson N2
compatibility options for DDC controls
* Requires field supplied secondary heat exchanger.
Copeland scroll compressorswith dual-isolation mountingfor quiet operation
Advanced digital controlswith Remote ServiceSentinel and compressorrun and fault LED
TMW Series design allows forsingle side service access.Units may be installed side-by-side
Extended range insulatedwater/refrigerant circuit standard
Optional Enhanced controls(DXM) & DDC Controllers
Small footprint withconvenient front serviceaccess (TMW036 shown)
37
7/22/2019 Climate Master Com Proj LC007
38/48
performanCe and SpeCifiCaTionS
AHRI/ISO/ASHRAE 13256-2 Data (English (IP) Units*)
Dimensional Data
ModelOverall Cabinet
W D H
036-060in.
cm
25.4
645
30.6
778
33.0
83.8
120in.
cm
52.9
134.4
30.6
778
37.0
940
170-340in.
cm
26.3
669
45.1
1146
64.5
163.8
All ratings based upon operation at the lower voltage of dual voltage rated models.* Indoor = Load side heat exchanger; Outdoor = Source side heat exchanger.
Model Volts Phase
036
208/230
265
208/230
460
575
1
1
3
3
3
060-120
208/230
208/230
460
575
1
3
3
3
170-340
208/230
460575
3
33
Voltage Options
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling Heating Cooling Heating Cooling Heating
Indoor 53.6FOutdoor 86F
Indoor 104FOutdoor 68F
Indoor 53.6FOutdoor 59F
Indoor 104FOutdoor 50F
Indoor 53.6FOutdoor 77F
Indoor 104FOutdoor 32F
CapacityBtuh
EERBtuh/W
CapacityBtuh
COPCapacity
BtuhEER
Btuh/WCapacity
BtuhCOP
CapacityBtuh
EERBtuh/W
CapacityBtuh
COP
TMW-036 HFC-410A 33,000 14.6 44,000 5.0 37,000 23.1 36,000 4.0 34,000 16.8 28,000 3.1
TMW-060 HFC-410A 55,400 14.1 79,000 4.7 62,600 21.7 61,400 3.8 58,000 15.4 51,000 3.0
TMW-120 HFC-410A 110,800 13.8 158,000 4.6 125,200 21.3 122,900 3.7 116,000 15.1 102,000 3.0
TMW-170 HFC-410A 126,000 13.6 168,000 4.4 141,200 19.7 139,000 3.8 133,000 15.6 110,800 3.0
TMW-340 HFC-410A 253,500 13.6 336,200 4.4 282,000 19.6 277,000 3.7 266,600 15.6 220,000 3.0
Model Refrigerant
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling Heating Cooling Heating Cooling Heating
Indoor 12COutdoor 30C
Indoor 40COutdoor 20C
Indoor 12COutdoor 15C
Indoor 40COutdoor 10C
Indoor 12COutdoor 25C
Indoor 40COutdoor 0C
CapacityWatts
EERW/W
CapacityWatts
COPCapacity
WattsEERW/W
CapacityWatts
COPCapacity
WattsEERW/W
CapacityWatts
COP
TMW-036 HFC-410A 9,672 4.3 12,896 5.00 10,844 6.77 10,551 4.00 9,965 4.92 8,206 3.10
TMW-060 HFC-410A 16,237 4.13 23,154 4.70 18,347 6.36 17,995 3.8 16,999 4.51 14,947 3.00
TMW-120 HFC-410A 32,474 4.0 13,572 4.60 36,694 6.24 36,020 3.74 33,998 4.42 29,895 3.00
TMW-170 HFC-410A 37,163 4.0 49,414 4.40 41,383 5.77 40,739 3.80 38,980 4.57 32,474 3.00
TMW-340 HFC-410A 74,297 4.0 98,535 4.40 82,649 5.74 81,184 3.70 78,136 4.57 64,478 3.00
TMW 036 - 340 Performance Data ASHRAE/AHRI/ISO 13256-2 60Hz Metric (SI) Units
38 THe roofTop (Tre) SerieS
7/22/2019 Climate Master Com Proj LC007
39/48
The Rooftop (TRE) Series provides an economicalsolution for todays HVAC challenges. The TREproduct line offers the option of introducing a fixedamount of outside air year-round or a modulatingEconomizer to provide free cooling when outdoorconditions are favorable. TRE units are designed foran extended range of source water temperatures,making it suitable for closed-loop, or ground sourceclosed-loop systems. With high efficiency scroll
compressors and belt drive motors, the TRE productline offers 13+ EER and 4+ COP.
uniT feaTureS
Sizes 036 (3 tons, 10.6 kW) through 240 (20 tons,70.4 kW)
EarthPure(HFC-410A) zero ozone depletionrefrigerant
Exceeds ASHRAE 90.1 efficiencies (40% betterthan standard rooftop units!)
Galvanized steel construction and powder coatpaint on all units
Copeland Scroll compressors (dual circuited onsizes 096 and larger)