1
0 50 100 150 200 250 HS-Mikro Pak 4V 95 HS-Mikro Pak 4V 85 HS-Mikro Pak 4V 65 100% 70% nergieverbrauch 20 25 Frame corrosion resistant plastic Operational conditions max. rel. h. 100 [%] max. temp. 65 [°C], short term peak up to max. 80 [°C] optional up to max. 120 [°C] Spacers thermoplastic (minipleat) Filtermedia high quality glass fibre paper (water resistant), pressure drop may temporarily increase at high humidity levels Optional: fully synthetic filtermedia for maximum rigidity, higher mechanical stress tolerance Combustible YES Options 1.) burst protector / protection screen 2.) foamed gasket on the clean air side of the flange 3.) +14% more filtersurface 4.) temperature resistance up to 120°C Example applications main filter for gas turbines pre- and mainfiltration for particle and finedust removal main flter for comfort air filtration Initial pressure drop [Pa] Nominal air flow [m 3 /h] HS-Mikro Pak 4V compact filters serve as pre-filter and main filter when high flow rates and high initial efficiency are required. These filters offer more filter surface than the classic HS-Mikro Pak and can therefore achieve a higher dust storage capacity and thus longer service life. Thanks to the aerodynamically shaped inlet profiles, these filters offer significantly lower ini- tial pressures than comparable filters from other manufacturers. The robust plastic frame is corrosion-free and allows easy disposal - the filter is completely incinerable. For applications with the highest demands, the filter can be reinforced on the clean air side with burst protection grids. HS-Mikro Pak 4V Detail: flange dimension (without gasket) Displays also options 1 & 2. Compact Filter – documents might be subject to change / issue Sept. 2021 Typ: HS-Mikro Pak 4V Energy class acc. to 65 85 95 Eurovent 4/21 Class EN 779 M6 F7 F9 Class ISO 16890 ePM10 85% ePM1 65% ePM1 90% Initial-P [Pa] (A / B) 65 / 120 75 / 140 85 / 165 Recc. final P 600 Max. temp. [°C] 65° (optional 120°) Dimensions [mm] Nominal air flow [m 3 /h] Weight Width Height Depth A: standard B: high flow rate [kg] 592 592 292 3400 5 000 7 kg 490 592 292 2800 4 100 5 kg 287 592 292 1700 2 500 3 kg Please ask for other desired designs. HS-Luftfilterbau GmbH Bunsenstraße 31 D-24145 Kiel Germany Tel.: +49 (0) 431 71953 0 Fax: +49 (0) 431 71953 30 www.luftfilterbau.de info@luftfilterbau.de Dok.-ID: 06/D13 Seite 1/1 Page Doc.-ID:

Compact Filter – HS-Mikro Pak 4V - Luftfilterbau

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Compact Filter – HS-Mikro Pak 4V - Luftfilterbau

46 |

Dok

.-ID

: 06/

D13

0

50

100

150

200

250 HS-Mikro Pak 4V 95

HS-Mikro Pak 4V 85

HS-Mikro Pak 4V 65

100%70%

Niedriger Energieverbrauch

Hoher Energieverbrauch

Niedriger Energieverbrauch

Hoher Energieverbrauch

A

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A A

B B

C C

D D

E E

F F

1 v. 2A2

Mikro Pak 8 Pakete

MP4V-OPTStatus Änderungen Datum Name

Gezeichnet

Kontrolliert

Norm

Datum Name14.07.201714.07.2017

DPEMSC

(C) HS Luftfilterbau GmbHhttp://www.luftfilterbau.de

Rev.: 1Material: KSToleranzen: +1 / -2 mm

HSL-Werksnorm

25

19

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A A

B B

C C

D D

E E

F F

1 A2

Deka-Pak-1Status Änderungen Datum Name

Gezeichnet

Kontrolliert

Norm

Datum Name24.05.2013 ap4

20

25

www.luftfilterbau.com

Frame corrosion resistant plastic

Operational conditions ▪ max. rel. h. 100 [%]

▪ max. temp. 65 [°C], short term peak up to max. 80 [°C]

▪ optional up to max. 120 [°C]

Spacers thermoplastic (minipleat)

Filtermedia ▪ high quality glass fibre paper (water resistant), pressure drop may

temporarily increase at high humidity levels

▪ Optional: fully synthetic filtermedia for maximum rigidity, higher

mechanical stress tolerance

Combustible YES

Options 1.) burst protector / protection screen

2.) foamed gasket on the clean air side of the flange

3.) +14% more filtersurface

4.) temperature resistance up to 120°C

Example applications ▪ main filter for gas turbines

▪ pre- and mainfiltration for particle and finedust removal

▪ main flter for comfort air filtration

Initi

al p

ress

ure

drop

[Pa]

Nominal air flow [m3/h]

HS-Mikro Pak 4V compact filters serve as pre-filter and main filter when high flow rates and high initial efficiency are required.

These filters offer more filter surface than the classic HS-Mikro Pak and can therefore achieve a higher dust storage capacity and thus longer service life.

Thanks to the aerodynamically shaped inlet profiles, these filters offer significantly lower ini-tial pressures than comparable filters from other manufacturers. The robust plastic frame is corrosion-free and allows easy disposal - the filter is completely incinerable.

For applications with the highest demands, the filter can be reinforced on the clean air side with burst protection grids.

HS-Mikro Pak 4V

Detail: flange dimension (without gasket)Displays also options 1 & 2.

Compact Filter –

docu

men

ts m

ight

be

subj

ect t

o ch

ange

/ is

sue

Sept

. 202

1

Typ: HS-Mikro Pak 4V Energy class acc. to65 85 95 Eurovent 4/21

Class EN 779 M6 F7 F9

Class ISO 16890 ePM10 85% ePM1 65% ePM1 90%

Initial-∆P [Pa] (A / B) 65 / 120 75 / 140 85 / 165

Recc. final ∆P 600

Max. temp. [°C] 65° (optional 120°)

Dimensions [mm] Nominal air flow [m3/h] WeightWidth Height Depth A: standard B: high flow rate [kg]

592 592 292 3400 5 000 7 kg

490 592 292 2800 4 100 5 kg

287 592 292 1700 2 500 3 kg

Please ask for other desired designs.