Upload
doankhanh
View
609
Download
30
Embed Size (px)
Citation preview
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 1
Compress 6000 AW
Air- water heat pump
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties.
Summary
• Heat pumps is designed to be
positioned outdoors to extract energy
from the outside air
• Consists from outdoor and indoor units
connected with water pipes (Compact)
• Heating, hot water and cooling
• To be used stand alone or in
combination with an existing electrical/
oil/ gas boiler
• For new build and renovated houses
2
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 3
Product presentation
Outdoor unit
AW-5 AW-7 AW-9 AW-13 AW-17
Max output
A7/W35
5kW 7kW 9kW 13kW 17kW
Max output
A2/W35
4kW 6kW 8kW 11kW 14kW
Power supply 1-phase* 1-phase* 1-phase* 3-phase 3-phase
* In 3-phase installation you can connect a
power guard that control software.
Note: accessory.
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 4
Product presentation
Versatile- many indoor units
AWM
Tower
AWMS
Solar tower
AWE
Wall hung
AWB
Wall hung
1800x600x635 1800x600x635 700x485x386 700x485x386
• DHW-tank 190L
• 9 or 15kW
electrical heater
• 14L exp. vessel
• DHW-tank with
solar coil
• 9 or 15kW
electrical heater
• 14L exp. vessel
• 9 kW el. heater
• 10L exp. vessel
• Mixing valve
• 230V on/off or
0-10V signal
DHW DHW
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 5
Product presentation
Best in class COP
COP
5,1
COP
4,2
kW Size 2 1~ph Size 3 1~ph Size 4 3~ph Size 5 3~ph
A7/W35 max 7 9 13 17
A7/W35 40% EN14541
2,96 3,43 5,11 5,20
COP 4,84 5,06 4,90 4,99
A2/W35 max 6 8 11 14
A2/W35 60% EN14511
3,90 5,11 7,11 7,40
COP 4,13 4,22 4,05 4,03
A-7/W35 max EN14511
6,18 8,43 10,99 12,45
COP 2,82 2,92 2,85 2,55
3.0
3.5
4.0
4.5
4 kW 6 kW 8 kW 11 kW 14 kW
A2/W35
NEW TT
TT Air
NIBE - F2040
Thermia /Danfoss - Atec
Alpha Innotec - LWA
Dimplex - LA*TU
Stiebel Eltron - WPL*A /*E
CTC - EcoAir 400
Viessmann - Vitocal 300-A
Daikin Alterma
Strictly confidential | TT-HP/PRM1 | May 2014 | SIP3 8118 | © Bosch Thermoteknik AB 2014. All rights reserved, also regarding any disposal,
exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Product presentation
Thermotechnology
Comparison with competition
Acc EN 14511
inverter
inverter
inverter
COP
2014-04
TOP COP
4,22
inverter
6
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties.
Best in test
Test in Danske Teknologiske
Institut on behalf of Danska
Energistyrelsen (Danish Energy
Agency)
54 air/ water heat pumps from 10
different brands
Bosch Compress 6000 AW has the
best SCOP on the market
Up to 21% better than competitors
Results: http://sparenergi.dk/
7
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 8
New refrigerant circuit with R410A
Inverter
technology
Electronic
expansion
valves
8
Product presentation
Latest
generation of
inverter control
High efficiency twin
rotary compressor
2 electronic
expansion valves
for better control and
higher COP
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties.
Why inverter controlled compressor?
Delivers only the power you need right now. Buffer
tank is not necessary (depending on type of heating
system)
More stable flow temperature
More efficient than On-Off compressor at part load
Refrigerant circuit working against oversized
exchangers at part load
Low start current. Soft-starter not necessary
9
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties.
Compact and quiet
Compact outdoor units:
7-9 kW 930 x 440 mm
13-17 kW 1120x 530 mm
Variable speed fan
EPP body effectively reduces both
vibrations and noise
10
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 11 Strictly confidential | TT-HP/PRM1 | May 2014 | SIP3 8118 | © Bosch Thermoteknik AB 2014. All rights reserved, also regarding any disposal,
exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Thermotechnology
Low noise
Sound
power
53 dB(A) (air+7)
Sound
Pressure 1m
40 dB(A) (air+7)
*Acc EN 12102 (@A7)
+ Silent mode to reduce 3 dB(A)
Silent mode
(night mode)
-3 dB(A) 6 am 10 pm
Low noise
Normal noise
dB(A) AW-5 AW-7 AW-9 AW-13 AW-17
Nominal* sound power 53
Nominal sound pressure, 1m 40
Max sound power w/o silent mode 64 65 67 68
Max sound power with silent mode 61 62 64 65
11
Product presentation
50.0
55.0
60.0
65.0
70.0
75.0
80.0
5 kW 7 kW 9 kW 13 kW 17 kW
A7/W35
NEW A/W
NIBE - F2040
Thermia /Danfoss - Atec
Alpha Innotec - LWA
Dimplex - LA*TU
Stiebel Eltron - WPL*A /*E
CTC - EcoAir
Viessmann - Vitocal 300-A
Daikin Alterma
Strictly confidential | TT-HP/PRM1 | May 2014 | SIP3 8118 | © Bosch Thermoteknik AB 2014. All rights reserved, also regarding any disposal,
exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Thermotechnology
Comparison with competition
Acc EN 12102 dB(A)
2013-10
inverter
inverter
inverter
inverter
12
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 13
Thermotechnology
Designed for Nordic climate
Manufactured in Sweden
Optimized for heating in cold
climate down to -20 C
Adapted to snow conditions-
evaporator and fan are ~40 cm
above the ground!
Integrated drip pan with heater
and alarm (patent)
Smart soft defrost (patent)
13
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 14
Product presentation
With SSD (Smart Soft Defrost) heat pump delivers heat continuously at
outdoor temp above +5°C.
Defrostning is performed at three
different ways.
1. At outdoor temp above +5°C, fan speed at maximum while the compressor
speed is limited until defrosting is completed. This allows continuously heat
during defrost mode.
2. If ”Silent mode” is activated, fan speed is unchanged while compressor is off
during defrost mode.
3. At colder outdoor temperatures, below +5°C, the heat pump change refrigerant
circuit to hot gas defrosting, suitable for inverter controlled compressor.
Continuously
heating production
Outdoor temp
Flow temp
Designed for Nordic climate
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties.
Easy to install and service
Low weight, easy to transport.
Service friendly, only 8 screws, easy
access to all components.
New logistic concepts- the plates
are not mounted from the factory.
15
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties.
Control options
DHW, heating and cooling
Outside temperature compensated control
LCD room sensors, control influenced by
room temperature
Time programs
Up to 4 heating circuits (with accessory)
Mixed additional heat (with ASB)
Pool control (with accessory)
Solar control (with accessory)
Prepared for remote control
16
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 17 Strictly confidential | TT-HP/PRM1 | May 2014 | SIP3 8118 | © Bosch Thermoteknik AB 2014. All rights reserved, also regarding any disposal,
exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Thermotechnology
Operation range
-20 -10 0 +10 +35
45
50
55
60
65
-5
Flow temperature [°C]
(w/o el heater)
Outside air
temperature [°C]
DHW mode only
62 +4
The NEW A/W allows flow temperature up to 62°C
Limits:
-20 / +35°C
heating
Up to 62°C
Reversibility
for all
models
Limits:
+15 / +45°C
cooling
Central heating
HEATING COOLING
Flow temperature [°C]
22
+15 +25 +35 +45 +18
7
Outside air
temperature [°C]
23
Central cooling
17
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 18
Hardware
Hardware
Heat Pump
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. TT/SPx
Heat pump
Evaporator
Electronik box Modulating fan
19
Driptray with
heater
Cable channel
EPP-material
Adjustable feet
Hardware
Metal plates
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 20
Hardware
Drip tray with integrated heater
Integrated drip tray with heater and sensor. Alarm is displayed if the drip
tray is clogged or blocked with ice.
The output on the heater is 50 W small model and 75 W big model. The
heater is activated only during defrosting.
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 21
Hardware
Inverter control
Double expansion valves
Condenser
4-way valve
Compressor
Receiver
Suction accumulator
To and from evaparator Refrigerant circuit
R410A
1-phase HP less than 3kg
3-phase HP less than 4kg
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties.
Inverter controlled rotary compressor
Double rotation Mitsubishi Electric compressors
with liquid separator. 3 pcs of compressor sizes
depending on model.
Works in 20 different steps.
Better at low or intermediate speed where scroll
has problem to deliver effect.
Low noise
Smaller
22
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 23
Hardware
No compressor heater
We don´t need a compressor heater to avoid unvaporized refrigerant
to reaching and damaging the compressor.
The motor of the compressor generates heat which may possibly
remain unvaporized refrigerant in the compressor to evaporate.
Invertern detects the torque in the start-
moment and start the compressor smooth
and carefully.
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 24
Hardware
Inverter
The inverter is cooled by the suction pipe. The efficiency is better in the
refrigerant circuit and ”free” cooling of the inverter.
The losses in the inverter are regained.
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 25
Hardware
Sensor location in refrigerant
circuit
TR1 Compressor
TR6 Hot gas
TC3 Condenser
TR3 Fluid temp refrigerant (condenser)
TR4 Fluid temp refrigerant (evaporator)
TA4 Drip tray sensor
TL2 Outdoor sensor evaporator
TR5 Suction gas
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 26
Hardware
Sensor
Three new, colour coded sensors with a new characteristic. Adapted
for better temperature touch in respective temperature area in the
heat pump.
The characteristic for respective sensor is noted in the manual.
Colour codes:
Red optimized at 40°C
Black optimzed at 80°C
Gray optimized at 0°C
Note: Sensors for earlier editions of heat pump models do not work!
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. TT/SPx
Pressure sensor
refrigerant circuit
MR1 High pressure switch
JR1 High pressure sensor
JR0 Low pressure sensor
Low pressure switch is not needed
as there is a low pressure sensor.
27
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 28
Hardware
Expansion valves and receivers
Double expansion valves to use the heat exchangers at maximum
at part load. The receiver is handling the redundant refrigerant.
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 29
Hardware
Function of the expansion valves
Expansion valve 1 regulates the sub cooling in the condenser depending
on the operating mode.
Expansion valve 2 regulates the over heating in the evaporator.
(in cooling/defrost mode the function will switch)
Condenser Evaporator 1 2
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 30
Hardware
4-way valve
4-way valve changes the direction in the refrigerant circuit from heat
mode to defrost mode or cooling mode.
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 31
Hardware
Electric box with I/O-module
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 32
Hardware
Hardware
Indoor units
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties.
Floor standing unit AWM
• 2 sizes: 5-9 and 13-17 kW
• special Solar modules
• 600 x 645 x 1800 mm, ~135 kg
• 190 l stainless steel DHW cylinder
• 3-way valve for DHW or heating
• 9 or 15kW additional electric heater
• LECP heat carrier pump
• expansion vessel 14L
• user interface
• built in IP-module for remote control
• connections from the top
33
Hardware
1800mm
600mm
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. TT/SPx
Safety assembly
1. Pressure relief valve
2. Automatic air vent valve
3. Flow sensor
4. Connection for circulation
pump heating system
5. Pressure gauge
6. Flow heating system
7. Return heating system
8. Bypass
9. Particle filter
34
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 35
Hardware
DHW-tank
• Looses less than 1,4kWh/ 24 hours
• A-classed
• Only stainless steel
• Anode as option
• Charge coil
• Area Charge coil 1,94m²
• Pipe pength 24,7meter
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 36
Hardware
• Same components as in
the ordinate AWM but with
an integrated solar coil.
• 2 sizes: 5-9 and 13-17 kW
Solar floor standing unit AWMS
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 37
Hardware
Electric box AWM (S)
Room for 2 pcs mixing valve modules
(accessories)
Installer-module
3pcs contactors for the addidtional
electrical heater
Miniature circuit breaker (15kW model)
Terminals
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 38
AWE
•Expansion vessel 10L
•9 kW electrical heater 1~ or 3~
•Pressure switch: security maximum
•Air vent (automatic + manual)
•Safety valve
•Pressure gauge
• Insulation
•LECP pump
•Possibility to clip 1 NSC module inside
• IP connectivity integration
Size: 700x485x386 (HxWxD)
With el box
Without el box
38
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 39
Size: 700x485x386 (HxWxD)
-Air vent (automatic)
-Mixing valve
-By-pass
LECP pump
-Possibility to clip 1 NSC module inside
-IP connectivity integration
-Safety valve
-Pressure gauge
With el box
Without el box
No change
of heat
emitters
+ tariff optimization included – more savings
39
AWB
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 40
Hardware
Circulation pump
and additional
electric heater
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 41
Circulation pump
ΔT-controlled LECP-heat carrier pump.
It has 7K Δ when heating and 3K Δ when
cooling. Note: PWM-controlled circulation
pumps.
• Wilo: AWM (S) 13-15
• Grundfoss: AWB, AWE and AWM (S) 5-9
External heat carrier pump installed outside
indoor unit and do not follow the delivery.
Size of this circulation pump determined by
the heating system.
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 42
DHW switching
Smart hot water switch controls the speed of the heat
carrier pump and on/off at the heating circuit pump.
• Avoid cracking noises
• Aviod cold water into DHW-tank during cooling mode.
Hot water production only starts when there is no cold
water between condenser and indoor unit. 3-way valve
waiting to switch over.
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 43
Software controlled power guard
When 1-phase heat pumps installed in 3-phase houses, you can
monitor the power on each phase. L1 and L2 is connected to the
electrical heater, L3 to the heat pump. The power guard controls the
software and if necessary limit the electrical heater or compressor so
that not the main fuse blows
when other power demanding
devices are used.
Power guard Tower 1-phase heat pump
CANbus CANbus
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. TT/SPx
Power consumption
House with 9kW peak load. 9kW Tower with 9kW heat pump.
L1 L2 L3 N
GND
CANbus
L3 N GND
400V 3-phase to Tower Current L1 Current L2 Current L3 Heat pump
K1 = 2000w 4,3 4,3 3-16 On
K2 = 4000W 8,7 8,7 3-16 On
K1+K2 = 6000W 13,0 13,0 3-16 On
K1+K3 = 3000W 4,3 4,3 4,3 Off
K2+K3 = 6000W 8,7 8,7 8,7 Off
K1+K1+K3 = 9000W 13,0 13,0 13,0 Off
Maximum 15amp
on L3 at +2ºC
outdoor temp and
high flow temp.
44
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. TT/SPx
Power consumption
House with 15 kW peak load. 15 kW Tower with 17 kW heat pump
L1 L2 L3 N
GND
CANbus
L1
N
GND
400V 3-phase to Tower Current L1 Current L2 Current L3 Heat pump
3000W 4,3 4,3 4.3 On
6000W 8,7 8,7 8,7 On
9000W 13,0 13,0 13,0 On
12 000W 17,4 17,4 17,4 Off
15 000W 21,7 21,7 21,7 Off
L2
L3
Max 12amp
L1, L2, L3
45
Hardware
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 46
Accessories
CR10
Room controller
CR10H
Room controller with
humidity sensor
for cooling
MM 100
Control mixed
heating circuit (2, 3, 4)
MS 200
Control solar for DHW
+ central heating
MP 100
Control a swimming pool
Common TT New System Controller
MS 100
Control solar for DHW
46
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 47
Room controler CR 10
• Shows indoor temperature
• Shows set point value indoor
• Can be addressed for 4 heat circuits
• Indicates possible alarm
• Communicates via EMS bus (2-wired cable)
Room controler CR 10H
• Measure the humidity level in the house and
stop the cooling function before it starts to dew
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 48
Condensation sensor
• Condensation guard stop the cooling if
condensation develops on the heating
system pipes.
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 49
Protective anode
Our stainless steel DHW-tank in the AirModule can take negative
charged chloride ions up to 250 mg/liter. If the water exceeds this
concentration a protective anode must be installed to avoid galvanic
korrision.
Product presentation
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 50
Product presentation
System solution
Heat pump with Tower,
one unmixed circuit and
one mixed circuit
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 51
Product presentation
System solution
Heat pump with Wall hung Comfort
and external DHW-tank, one
unmixed and one mixed circuit.
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 52
Product presentation
System solution
Heat pump with Wall hung Light,
external DHW-tank, mixed
additional heat, one unmixed and
one mixed circuit.
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 53
Product presentation
System solution
Heat pump with Tower and buffer, two
mixed circuits
Strictly confidential | TT/STR | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
We reserve all rights of disposal such as copying and passing on to third parties. 54
System solution
Heat pump with Wall hung Comfort,
external DHW-tank and buffer, one
unmixed and one mixed circuit.
Product presentation