36
1

Contents to Water Heat Pump ... quality control process to ensure the ... allowed to installed indoor Coal boil heater Relatively Safe 5-8 years

Embed Size (px)

Citation preview

1

Contents

Company Profile ............................................................................. 3

Qualification Certificates ............................................................... 4

Heating Price Performance Ratio .................................................. 5

Air to Water Heat Pump ............................................................ 6 - 7

Swimming Pool Heat Pump ....................................................... 8 - 9

Swimming Pool Pioneer Series.............................................. 10 - 11

All In One Heat Pump ............................................................ 12 - 13

Split Type ................................................................................ 14 - 15

High Temperature Heat Pump .............................................. 16 - 17

Water to Water Heat Pump ................................................... 18 - 19

Multifunction Titanium .......................................................... 22 - 23

Commercial Tank (Pressurized & Non Pressurized)............. 20 - 21

Solar Cell System .................................................................... 28 - 30

Dryer Heat Pump .................................................................... 26 - 27

Project References ................................................................. 31 - 35

Tank Only ........................................................................................... 25

Gas Water Heater ........................................................................... 24

2

3

Company Profile

In 2009, the Company introduced Heatpump water heater to Indonesia.

In 2012, the Company introduced independent new brand of heatpump water heater "HiCOP" with excellent quality and best price.

The Company devotes to specialize in distributing energy-efficient heat pump and hot water unit, mainly for guesthouses, hotels, schools, offices, factories, hospitals and villas all over Indonesia, to provide energy-saving central heating and hot water systems solutions, of which rate can be 75% or higher.

In 2014, HiCOP introduced High Temperature Heat Pump to substitute boilers for industries. With High Coefficient of Performance (Hi COP), this unit more efficient and environmentally friendly. HiCOP also introduced commercial tank (pressure

and open tank) with high quality material.

In 2015, the company introduced Solar Cell System (PV). Today, thousands of people power their homes and businesses with individual solar PV systems.

As leader in heat pump water heater, our technologies included products design, energy saving and high productivity products development, we have excellent experience, passionate work force and strong after sales service which make possible to provide the highest level of service and speedy response to market demand.

Our product go through strict international regulation test and our quality control process to ensure the high standard of quality before delivery.

PT. Simed Prakarsa Indonesia has established in 1982 and distribute water heater of famous brands: Solahart Water Heater, Handal Water Heater, Raypak Water Heater and Handal Water Filter.

3

4

Qualification Certificates

• Adopting International standard product marking certificate

• SGS CE certificate 3

• TUV CE certificate 3

• TUV CE certificate 9

• Declaration of the strategic partner with American Copeland

• SGS CE certificate 4

• TUV CE certificate 4

• TUV CE certificate 10

• High-tech products certificate

• SGS CE certificate 5

• TUV CE certificate 5

• TUV CE certificate 11

• ISO9001 certificate

• SGS CE certificate 6

• TUV CE certificate 6

• TUV CE certificate 12

• SGS CE certificate 1

• TUV CE certificate 1

• TUV CE certificate 7

• TUV CE certificate 13

• SGS CE certificate 2

• TUV CE certificate 2

• TUV CE certificate 8

• TUV CE certificate 14

4

5

Heating PricePerformance Ratio

Economic Value Comparison Table

Heat Pump compared to other water heater system

Name Safety Equipment Lasting Life Practical Utility

HiCOP Heat Pump Safe Up to 15 Years Low power consumption, safe,

eco-friendly

Solar Heater Relatively Safe 3-8 years

Be affected by weather changes,Unstable water temperature, Needelectric heater back up when in rainingor cloudy days

Electricheater Relatively Safe 3-5 years

High running cost, Fear of electricityleakage accidents

Gasheater Relatively Safe 3-5 years

May happen gas explosion, toxic, notallowed to installed indoor

Coal boilheater Relatively Safe 5-8 years

Pressure devices, pollusion, need specialist security check annually

The following drawings are calculated in an electricity bill of 0.11 USD, the actual costs shall be calculated preferentially based on local unit price

Heating Type Calorie of Energy

Energy/Performance

RatioUnit Price

Required Energy (per ton water)

Required Cost (Per ton

water)

All Year Cost (10 Ton water

per day)Labor Cost Coverage

Annual Operation

Cost

Coal Boiler 4000Kcal/kg 40% $0.08/kg 25.10kg $2.32 $7513 $5128 20M3 $12641

Oil Boiler 8429Kcal/kg 80% $0.6/l 6.40 l $3.84 $14012 $5128 20M3 $19141

Liquefied Gas 10800Kcal/kg 73% $0.85/kg 5.30kg $4.48 $16371 $2564 10M3 $18936

Solar Electric Heating 860Kcal/Kwh 85% $0.09/Kwh 51.6Kwh $1.92 $7026 NO 150m2 $7026

Electric Boiler 860Kcal/Kwh 90% $0.09/Kwh 51.6Kwh $4.63 $13487 NO 10-15M3 $13487

HiCOP 860Kcal/Kwh 400% $0.09/Kwh 13Kwh $1.17 $4256 NO 3-10M3 $4256

- Inlet temperature 15OC, Ambient Temperature 20OC, Target Temperature 55OC

6

1. Copeland with R417a or Daikin with R410a scroll compressor, high efficiency and stable functions.

2. Emerson ALCO thermal expansion valve, with accurate and stable throttling performance.

3. Al-Mg fan motor with Nylon fan blades, low noise, low power consumption, big air blow volume.

4. High efficiency Tube in tube heat exchangers, low fouling and easy for maintenance.

5. Coated steel or SUS304# stainless steel case, avoiding rust effectively and durable.

Air To WaterHeat Pump

Overview

Features

HIGH COPUsing high technology of heatpump, make the HiCOP air to water heatpump COP can reach to 4.

HIGH WATER TEMP 600CThe water temperature arrived at 600C and can be widely applied in preparation for heating and hot water.

QUIET RUNNINGUsing efficient, low noise, closed famous brand compressor and fan, ensure quiet running.

EXTREMELY COLD TEMP.HiCOP Heatpump can work securely and stably under -10 OC extremely cold environment, and normally provide hot water.

6

7

Construction

Item Description

Compressor Copeland Flexible Scroll

Refrigerant R417a

Expansion Valve Emerson

Cabinet Powder Coated Steel

Water Ingress Protection Rating IPx4

Heat Exchanger Coaxial Coil, Tube in Tube

Controller Multi-Function Digital

Fan Fibre Nylon

Fan Motor Alumunium Magnesium Alloy

Model AW-10 AW-21 AW-30 AW-37 AW-50 AW-62 AW-72 AW-90 AW-105

Power Supply 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

* Heating Capacity kW 9.5 20.8 30 37.5 49 62 72 90 105

* Rated Power Input kW 2.5 5.2 7.5 9.2 12.1 15 18.5 22,5 27

Water Feed Speed L/H 204 430 645 806 938 1330 1548 2063 2257

Max. Current A 19.5 15 21 25 28.5 40.5 49 61 73.5

Rared Water Temp OC 55 55 55 55 55 55 55 55 55

Max. Water Temp 60 60 60 60 60 60 60 60 60 60

Level against electric shock | | | | | | | | | |

Net Weight Kg 100 165 260 275 295 495 622 670 893

Net Size mm(L*W*H)

690 x 700 x 800

800 x 800 x 1120

1200 x 920 x 1220

1200 x 920 x 1220

1200 x 970 x 1420

2080 x 1100 x 1676

2200 x 1135 x 2080

2400 x 1130 x 2300

2400 x 1300 x 2080

Required water flow rate m3/h 2.2 5 6 8 10 12 16 20 24

Required tank cubage 2-3 3-5 5-8 7-10 18-12 10-15 15-20 20-30 25-30

Water connection G1” G1” G1-1/4” G1-1/4” G1-1/4” G2” G2” G2” G2-1/2”

Operation temp. range OC -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45

Noise db(A) < 56 < 58 < 60 < 60 < 60 < 62 < 64 < 68 < 65

Working Principle

Note : HiCOP reserves the right to discontinue, or charge at any time, spesification or designs without notices and without incurring obligations.

8

Features

Swimming PoolHeat Pump

1. Copeland with R417a or Daikin with R410a scroll compressor, high efficiency and stable functions.

2. Emerson ALCO thermal expansion valve, with accurate and stable throttling performance.

3. Al-Mg f an motor with Nylon fan blades, low noise, low power consumption, big air blow volume.

4. Adopt Titanium Heat Exchanger, effectively erosion proof and durable.

5. Coated steel or SUS304# stainless steel case, avoiding rust and durable.

Overview

SAFE AND GREENHiCOP uses the heat pump technology to heat swimming pool water, which realises the separation between water and electricity.

Compare with gas heater system, heat pump is flameless and has no exhaust gas. Compare with electrical heater system, heat pump is without electricity leakage risk. It is safe and green to use the swimming pool heat pump.

HIGH COPUsing high technology of heatpump, make the HiCOP swimming pool heatpump COP can reach to more than 4.7

HIGH TEMPERATURE 450C HiCOP swimming pool heatpump can reach 450C of temperature, it is applicable for spa.

100% TITANIUM HEAT EXCHANGERUsing advanced titanium heat exchanger, greatly resist erosion of chlorine ion in pool water and durable.

8

9

The principle of heatpump is to pump the low grade heat from natural air into swimming pool water with the help of air heat exchanger.

This is how the HiCOP Swimming Pool Heat Pump heats up Pool Water Titanium Conventional

Material

Model SP-17 SP-39 SP-62 SP-74 SP-117 SP-156

Power Supply (V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50

Heating Capacity (kw) 16.2 39 62 74 117 156Power Input (kw) 3.4 7.5 11.3 14.5 20.1 36

Refrigerant R417a/R410aMax. curent (A) 13 25 40 50 75 100Rated water temp (oC) 28 28 28 28 28 28Level against electric shock I I | I I IWater-proof grade IPX4 IPX4 IPX4 IPX4 IPX4 IPX4Net Weight (kg) 130 250 465 622 893 1500Net size (mm) - (L*W*H) 800x800x970 1200x920x1220 2080x1100x1676 2000x1100x1790 2400x1300x2080 2400x1900x2080Required water flow rate (m3/h) 7,5 15 25 30 45 60

Water conection (mm) 50 mm 63 mm 75 mm 75 mm 75 mm 75 mmOperation temp range (oC) -10-45 -10-45 -10-45 -10-45 -10-45 -10-45

Noise dB(A) < 52 < 60 < 62 < 64 < 68 < 68

Test condition Ambient temp (DB/WB) : 20 oC/15 oCWater temp (Initial/Final) : 15 OC/28 OC

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

Working Principle

10

2 Titanium Coils ExchangerPatented Two Titanium Coils Heat Exchanger features extended work area with higher efficiency

Touch LCD DisplayEquipped with LCD Touch Display, this series of pool heat pumps provides users easy control experience and provides the units fine decoration.

Cost EffectiveThe COP of this series is as high as 5.3 at working condition of 24°C/19°C (DB/WB), which saves you at least 80% energy compared with traditional electric swimming pool heating.

Multiple ModelsContains 9 models ranging from 4kW to 23kW, users can make their favorite choice for a perfect energy saving swimming pool heating application.

2 Titanium Coils ExchangerPatented Two Titanium Coils Heat Exchanger features extended work area with higher efficiency

Ripple Fin Air ExchangerHeat exchanging surface extended, heat exchanging effect is improved and the risk of frosting is reduced.

Pressure ProtectionWith high/low pressure protection, heat pumps are protected at bad working conditions.

Water Flow SwitchThe water flow switches designed by HiCOP are with high sensitivity feature.

Swimming PoolPioneer Series

Features

10

11

Model SPP SPP-4 SPP-5 SPP-8 SPP-11 SPP-17 SPP-21 SPP-23

Heating CapacitykW 4 5,4 8,2 11,3 17 21 23

Btu/h 13600 18360 27880 38420 57800 71400 78200

Heating Power Input kW 0,9 1 1,53 2,1 3,48 3,7 4,1

COP - 4,44 5,4 5,36 5,38 4,89 5,68 5,61

Running Current A 4,1 4,6 7 9,6 6,8 7,2 8

Power Supply - 230V~/50Hz 380V/3N~/50Hz

Compressor Quantity - 1

Compressor Quantity - Rotary Scroll

Fan Quantity - 1 2

Fan Power Input W 90 120 150 120x2

Fan Rotate Speed RPM 850

Fan Direction - Horizontal

Noise dB(A) 47 47 51 54 56 56 56

Water Connection mm 50 50 50 50 50 50 50

Water Flow Volume m3/h 1,5 2,2 3 4,5 6 7,5 9

Water Pressure Drop (max) kPa 2 4 6 10 20 2,8 2,8

Net Dimensions (L/W/H) mm 756 / 290 / 570 956 / 372 / 600 1115 / 470 / 870 1002 / 455 / 1250

OverviewWith complete range of models from 4kW to 23kW, Pioneer Series is widely welcomed in global markets. In the working process of absorbing free heat from the air and transferring it to water, this series of heat pumps ensures constant and stable pool water temperature for you.

Heating: Outdoor air temp (DB/WB): 240C/190C, Water temp (in): 260CThe data above is only a reference, specific data please refer to the nameplate on the units.Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

12

HiCOP Domestic Heat Pump Water Heater With a COP which is 4 times higher than that of the water heater, this series of water heater is an environmentally friendly and new designed product special for providing domestic hot water. Enameled water storage tank used as the inner container of the water heater prevents corrosion and brings better quality water to the user; the coil which is fixed outside the water tank also avoids being corroded and its service life will be increased.

1. High COP of 4.0Apply compressors special for heat pump and acquire the COP of 4.0.

2. Long Service LifeCoil which is around the unit avoids direct contacts with the water and corrosion caused by negative ion, thus the service life would be prolonged.

3. Excellent Inner Container Apply enameled water storage tank with high hardness,

high temperature and high pressure resistance as the inner container which makes the water in the unit healthier and safer for use.

4. Thermostatic Expansion Valve Applying thermostatic expansion valve as the throttling

set makes the unit more adjustable in wide working temperature range and operate more stably and efficiently.

5. Environmentally Friendly Refrigerant R134a used as the refrigerant in the unit is pollution-free

and with good heating performance.

6. Good Looking Screen The screen with elegant looking can be set to orange or

blue background.7. Wireless Control - iPhone Cell phone can be used as a controller if there is a

relative application installed in it. The most fashionable Wi-Fi technology applied in the unit ensures you to check and set the unit whenever and wherever you want.

8. Intelligent Defrosting Using electromagnetic valve for defrosting makes the

least heat loss of the unit as there is no fluctuation in water temperature and this also ensures excellent performance of the unit.

9. P&T Relief Valve Apply P&T relief valve, which will automatically switch

on or off depending on thepressure or temperature in the tank, to ensure the safety of the unit.

Features

All In OneHeat PumpResidential Series

Overview

12

13

Special Compressor for Heat Pump

EnviromentallyFriendly

Refrigerant

Coil ArroundHeat Exchanger

ElectromagneticValve

Enamel InnerContainer

P&T Relief Valve

Thermostatic Expansion

Valve

Touch ScreenController

Wireless Control (optional)

Micro Channel (optional)

Components

Model All In One AI-80 Al-100 Al-200 Al-300 AO-270

Heating Capacity kW 1 1 1.8 1.8 3.4

Water Tank Capacity L 80 100 200 300 270

Power Input kW 0.27 0.27 0.46 0.46 0.88

Running Current A 1.2 1.2 2.0 2.0 3,97

Power Supply 230V~/50Hz 230V~/50Hz 230V~/50Hz 230 v~/50 Hz 240 v~/50 Hz

Compressor Rotary Rotary Rotary Rotary Rotary Rotary

Rated Outlet Water Temp 0C 55 55 55 55 55

Air Volume m3/h 220 220 350 350 270

Air Pressure Pa 30 30 40 40 40

Duct Diameter mm 150 150 150 150 -

Noise dB(A) 45 45 45 45 52

Water Inlet/Outlet Size Inch 1/2 1/2 3/4 3/4 3/4

* Auxiliary E-Heater kW 1,5 1,5 1,5 1,5 1,5

Net Dimensions mm 520x1215 520x1305 560x1732 640x1880 640 x 1865

Shipping Dimensions mm 710x640x1400 710x640x1525 720x720x1930 720x720x1990 720 / 760 / 1940

Net Weight kg 69 73 112 129 120

Measurement conditions :Instant heating : Ambient temperature 15OC/13OC, Water inlet 15OC, Water Outlet 45OCWork range : (1) Ambient temperature is -7-40OC (2) The max temperature of water tank is 60OCOperating parameters : The range of the operating water temperatures : 9~60OCThe range of the operating water pressures : 0.15~0.7 MPaNote : HiCOP reserves the right to discontinue, or change at anytime, spesifications or designs without notices and without incurring obligations.

14

Application

Split TypeHeat Pump

14

15

Micro-channel Heat Exchanger

HiCOP adopts micro-channel wrapped outside the water tank instead of the alumunium coil. The Cop of heat pump water heaters is reach to 2.9 based on the test standard En16147.

Intelligent Control

By setting different intelligent operation modes inside the controller, the unit is able to meet various requirements of different customer according to their actual needs.

Large Air Volume

The fan coil set in the outdoor unit will greatly enlarge the heat exchanger square and the COP of the split unit will get improvement, then lower the operation cost.

Specifications

Features

Models ST-200 ST-300

Water Volume (L) 200 300

Heating Capacity (kW) 2,5 2,5

Power Supply 230V~1/50Hz 230V~1/50Hz

Air Volume 1600m3/h 1600m3/h

Noise 47dB(A) 47dB(A)

Default Water Temp. 55 0C 56 0C

Water Outlet Temp. (Adjustable) 38 0C ~ 60 0C 38 0C ~ 60 0C

Net Weight (kg) 34+69 34+82

Net Dimension (mm) 350 x 780 x560 / Φ560 x1250 350 x 780 x 560 / Φ640 x 1450

16

EVI SystemThe units adopt EVI system combining with high-efficient heat exchanger, making the units more stable and energy efficient. Because of the application of these advanced heat pump technology, the units are with lower operation cost.

This series is presented the high water temperature up to 80 0C. With the concept of Green and Eco Energy. Suitable for industrial, Commercial and other necessities.

Higher Outlet Water Temperature 800

The outlet water temperature of the units can reach 800 C by circular heating to meet the need for high temperature, but the energy consumption is just 20% of boiler.

Safe and Pollution FreeDriven by electricity without danger of burning and explosion and adopting R134a eco-friendly refrigerant without pollution to the environment. Thus, the units are safe and pollution free.

Reduce CO2 EmissionsHeat Pump reduce million of tons of CO2 emissions from boiler.

High TemperatureHeat Pump

Overview

16

17

Model HT-14 HT-26 HT-54

Power Supply (V/ph/Hz) 380/3/50 380/3/50 380/3/50

* Heating Capacity (kW) 14 26 54

(BTU) 47768 88712 184248

* Rated Power Input (kW) 4.6 9.2 18

* Water Feed Speed (L/h) 185 370 741

* Test Condition * Ambient temp (Dry Buld/Wet Bulb):20OC/15OC, Water temp (in/out): 15OC/80OC

Refrigerant R134A

Refrigerant Weight (g) 4400 4400*2 4400*4

compressor (type) scroll

(number) 1 2 4

Fan

(type) Axial flow type with Nylon fan Blade

(discharging) Horizontal

(number) 1 1 2

(air flow)(m3/h) 5000 11000 7400*2Evaporator Alumunium/Cu lamellar tube evaporator

Condenser (heat exchanger) Coaxial coil heat exchanger (Copper Tube-in-Steel Tube)

Economizer (heat exchanger) Stainless Steel Plate

Throttling Device Emerson Thermal Expansion Valve

Controller Indoor Digital Controller

Required Water Flow Rate (m3/h) 4 8 16

Water Connection G1” G1-1/4” G2”

Required Tank Cubage (t) 3-5 7-10 15-20

Max. Current (A) 13 25 49

Noise dB (A) < 64 < 65 < 68

Level again electric shock | | |

Water proof IPX4 IPX4 IPX4

Max. Water temp (OC) 80 80 80

Operation temp. range (OC) -10-45 -10-45 -10-45

Net Weight (kg) 270 320 680

Net Size -(L*W*H) (mm) 800 x 800 x 1120 1200 x 970 x 1420 2150 x 1135 x 2080

Heating condition : outdoor temperature DB/WB 200C/150C; * outlet water 750C, inlet water (return) 700C. Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

18

Water to WaterHeat Pump

Specification

HiCOP Water to Water heat pump absorb heat (energy) from water source and transfer it to warm and heat the water, for domestic hot water and heating. The unit could be installed in indoors, as floating support for compressor to reduce vibration at the most extent and noise insulation inside the cabinet as well as noise jacket for compressor.

Plate heat exchanger-316L# stainless steel High efficiency, excellent performance.

LED Controller with touch screen---Simple operation, sensitive keypad.---Auto mode and manual mode are on your option.

SAGINOMIYA 4-way-valveto adjust regrigerant flow di-rection for defrosting/cooling.To control & indicate the gas outlet direction.

Plate heat exchanger-316L# stainless steel High efficiency, excellent performance.

Pressure GaugeIndicate system pressure varying with different tempera-ture of air and water

water source input water source output

water input water output

Overview

18

19

Model WW-20 WW-40 WW-60 WW-120

Power Supply V/ph/Hz 380/3/50 380/3/50 380/3/50 380/3/50

Heating Capacity kW 20 40 60 120

BTU 68240 136480 204720 409440

Rated power input kW 4.6 9.2 13.8 30

Cooling Capacity kW 15 30 45 90

BTU 51180 102360 153540 307080

Rated Power Input kW 3,6 7,1 10,8 21,4

Refrigerant R410A

Compressor Type Scroll

Required Hot Water Flow Rate m3/h 4 8 12 20

Required Water Source Flow Rate m3/h 3,2 6,4 9,6 24Water Connection G1” G1-1/4” G2” G3”

Noise dB(A) < 42 < 44 < 45 < 50Max. Current A 13 25 37 83Max. Water Output Temp. OC 60 60 60 60Water Source Temp. Range OC 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35Net Weight kg 120 250 500 750Net Size (L/W/H) mm 700x620x850 700x720x1290 1560x740x1380 2400x900x1380Heating by Water Source Temp. (In/Out) : 15OC / 7OC and Water Temp. (In/Out) : 15OC / 55OC ;

Cooling by Water Source Temp. (In/Out) : 25OC / 30OC and Water Temp. (In/Out) : 12OC / 7OC ;

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

Increasing the pressure raises the temperature

The ground loop transfers ground energy to a refrigerant inthe heat pump.

Heat is transfered to the heating water

Earth or Water Source

The refrigerant expandscausing it to cool

Heat is transfered to the room by radiators or underfloor heating / hot water for bath-room

Working Principle

20

Commercial Tank

1. High energy efficiency2. Patented and Safety product3. Applicable for commercial industries like hotel,

villa, hospital and factory4. Suitable for heatpump and gas water heater

complimentary5. High density insulation (eliminate heat loss)

1. Easy maintenance and installation2. Quality manufacturing standard3. Free technical consultation & design4. High quality installation5. Large variety of tanks based on needs6. Warranty: 5 years for non pressurized tanks,

1 year for pressurized tank.

Pressurized &Non Pressurized

Benefit Product Support

20

21

ModelHot Water Storage Tank (Pressurized)

1000 Liter 2000 Liter 3000 Liter 4000 Liter 5000 Liter 6000 Liter 7000 Liter 8000 Liter

Tank Material Stainless Steel SUS 304

Working Pressure (bar) 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8

Shell (mm) 3 3 5 3 4 6 3 4 6 4 5 8 4 6 8 5 6 8 5 8 8 5 8 8

Dome (mm) 3 4 6 4 5 8 4 5 8 4 6 8 5 8 8 6 8 10 6 8 10 6 8 10

Tank Weight (empty) (kg)

400 500 700 600 800 1100 700 900 1200 900 1200 1500 1100 1500 1700 1400 1700 2000 1600 1900 2100 1700 2000 2200

Tank Weight (full) (Mt) 1.4 1.5 1.7 2.6 2.8 3.1 3.7 3.9 4.2 4.9 5.2 5.5 6.1 6.5 6.7 7.4 7.7 8 8.6 8.9 9.1 9.7 10 10.2

Tank Diameter (mm) *

950 1200 1300 1400 1500 1550 1600 1650

Tank Height (mm) ** 2000 2400 2900 3200 3500 3800 4100 4300

Back Up Heater Optional (Heat Pump / Gas Heater / Electric Heater)

Thermostat Optional

Inlet Diameter (inch)

1.5 2 2 2.5 2.5 3 3.5 4

Outlet Diameter (Inch)

1.5 2 2 2.5 2.5 3 3.5 4

Drain Diameter (Inch)

1.5 2 2 2 2 2.5 3 3

Outer Skin Zincallume 0.5

Finishing Outer Skin Fined Yellow Coated

Heat Insullation High Density Polyurethane 50 mm

Accessories Safety Valve, Pressure Gauge, Temperature Gauge, Air Fan, Magnesium Anode

* Without Jacketing** Height Total

Model Hot Water Storage Tank (Non Pressurized)

Capacity 1000 Liter 2000 Liter 3000 Liter 4000 Liter 5000 Liter 6000 Liter 7000 Liter 8000 Liter

Tank Material Stainless Steel SUS 304

Shell (mm) 1.2 3 3 3 4 4 5 5

Dome (mm) 1.2 3 3 4 4 5 6 6

Tank Diameter (mm)* 1100 1200 1300 1400 1500 1550 1600 1700

Tank Height (mm)** 1600 2400 2900 3200 3500 3800 4100 4100

Tank Weight (empty) (kg) 300 500 600 800 1000 1300 1500 1600

Tank Weight (full) (Mt) 1.1 2.5 3.6 4.8 6 6.3 8.5 9.6

Back Up Heater Optional (Heat Pump / Gas Heater / Electric Heater)

Thermostat Optional

Inlet Diameter (Inch) 0.75 2 2 2.5 2.5 3 3.5 4

Outlet Diameter (Inch) 0.75 2 2 2.5 2.5 3 3.5 4

Valve Diameter 1” 2” (Customize)

Drain Diameter (Inch) 0.75 2 2 2 2 2.5 3 3

Outer Skin Zincallume 0.5

Finishing Outer Skin Fined Yellow Coated

Heat Insullation High Density Polyurethane 50 mm

Accessories Water Level Controller (WLC), Sight Glass, Temperature Gauge, Magnesium Anode, Floatless Switch

* Without Jacketing** Height Total

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

22

MultifunctionTitaniumHeat Pump

1. Wide applicationUsed in hotel, apartment, housing, villa, factories, schools, sauna, bathroom, SPA center, beauty salon, fitness center, swimming pool, aquaculture etc. where need cold and hot water.

Equipped with different forms of water end equipment, such as fan coil, floor heating, thermal radiation, thermal insulation water tank etc. to meet the users’ demands.

The modular structure apply to all kinds of scale projects, the best choice for office buildings, hotels, restaurants, movie theaters, shopping plaza, gymnasium, hopitals and other public places.

2. Patented product with multi-usage functionMultifunction patent with five modes: air heating, air cooling, domestic hot water, heating & hot water at the same time, cooling and hot water at the same time.

3. High efficiency and energy savingIn mode of cooling and hot water at the same time, COP can be up to 7.5.

Low running cost, comprehensive energy consumption is only 75% of the solar water heater, 25% of electric water heater.

4. High quality componentsUsing high efficient world famous brand compressor, plate heat exchanger or titanium heat exchanger to meet different use, accurate refrigerant control by electronic expansion valve.

5. Flexible configurationDifferent unit capacity and water tank capacity are for flexible configuration to meet different demands.

6. Flexible and convenient installationUnit installation position covers small area, connect through water pipe, no need for refrigerant pipe. Simple installation, reliable use, compact appearance.

7. Integrated design, multiple reliable protectionsIntegrated design, system sealed welding completely. Built-in multiple protections such as water flow protection, compressor discharge temperature protection, system refrigerant high/low pressure protection, compressor overcurrent protection, power supply phase sequence protection.

8. Environment friendlyUsing refrigerant R410A, no CO2 emission, no pollution, no waste gas, no waste residue discharge.

9. Advanced control and easy operationMicrocomputer control, LCD display, super power failure memory and timing on/off function, with remote ON/OFF and mode select control.

Features

22

23

Working Principle

Model MFT-10 MFT-14 MFT-18 MFT-21

Rated Output Water L/h 225 300 375 450

Cooling :Outdoor air temp: 350/240Outlet water temp:120,Input water temp:70C

Rated Cooling CapacityKW 7,5 10,0 12,5 15,0

BTU/H 25600 34200 42700 51200

Rated Input Power(Cooling) KW 2,63 3,51 4,39 5,26

Rated Input Current(Cooling) A 12,0 5,3 6,7 8,0

(1) Heating: Outdoor air temp: 200/150Cwater tank water temperature from150 heating to 550C

Rated Heating Capacity (1)KW 10,5 14,0 17,5 21,0

BTU/h 35900 47800 59800 71700

COP(1) W/W 4,05 4,05 4,05 4,05

Rated Input Power(Heating) (1) KW 2,59 3,46 4,32 5,19

Rated Input Current(Heating) (1) A 11,8 5,3 6,6 7,9

Working ambient temperature range 0C -5~43

Power Supply V/PH/Hz 220/1/50 380/3/50

Noise dB(A) 52 54 54 55

Compressor Rotary Scroll Scroll Scroll

Heat ExchangerHydrophilic Aluminum Fin Heat Exchanger

Titanium/ 316SS plateHeat Exchanger

Refrigerant Control Electronic Expansion Valve

Refrigerant Type R410A

Water Outlet/Water Inlet inch 1” 1” 1” 1”

Water Flow Volume m³/h 2 2,5 3 3,5

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

24

Gas Water Heater

• Over-temperature protection• Anti-dry burning protection• Accident flameout protection• Dual solenoid valve protection• Water flow switch stuck protection• High water pressure protection• 20 minutes timer shutdown protection

Features• Combustion exhaust system• Heat exchange system• Electric control system• Combustion system• Gas circulation system• Water circulation system

Model No. GWH-A6

Hot water capacity ∆250C (L/min) 6

Rated heat input (kW) 12

Product size (mm) 445*300*120

Packing size (mm) 590*327*195

N.W./G.W.(kg) 4.9/6.1

Digital display Yes, LED

Gas inlet/Water inlet/ Water outlet G ½’’

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

24

25

Mini Tank

HiCOP water storage tanks have high performance which meet with the requirement of CR (Pressure Equipment Directive 97/23/EC), Water Mark, UL, and NF certifcates standards.

The high pressure polyurethane resin forming is cyclopentane type CFC free insulation, which is in line with ROHS & REACH directive, and have a density around 42-45 Kgs/m3.

With advanced welding technology, the tanks have elegant appearance and good corrosion resistance.

PU Insulation coat is more and more popular in Europe market our this kind of tanks are warm welcome especially in Germany. This soft insulation layer gives good appearance of the tanks.

As a good choice for big tanks, it and can be easily removed from the inner tank if needed and more conveniently be handle during transport.

If your door is not large, please consider this type of tank !

Normal Capacity L 300 / 400 / 500

Inner Tank Diameter mm 500 / 600 / 600

Inner Tank material SUS 304

Max Working Pressure bar 6

Max Testing Pressure bar 10

Max Running Temperature

0C 90

E-Heater Screw Thread Type

Mg. Anode Optional

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

26

A heat pump dryer is a new type of drying device which transfers heat energy in the air into refrigerant to heating or drying. It successfully applies reverse Carnot principle by using electric energy to start and make refrigerant constantly accomplish the thermodynamic cycle process among evaporator, compressor, condenser and expansion valve. Heat pump dryer is very economical, capable of saving the 50% ~ 70% energy compared with the classical oven dryer.

Max. outlet temperature is up to 45C or 75C, and it is adjustable

Ligh touch control panel, with auto mode, manual mode, time funtion, easy for use

Adopted world famous brand components. Copeland compressor, Emerson ALCO expansion valve, etc

Consice outlook, saving the place

Energy-saving, Econimic, Environment-friendly

Multi-protection for savety, including over high pressure protection, over low pressure protection, phase protection, etc.

Features

Overview

DryerHeat Pump

26

27

This heat pump dryer is mainly for industrial use, such as tobacco, fruit, tea leaf, sea food, wood, cloth, painting, etc. Thic device comprises indoor units and outdoor units, integrating heating, cooling, moisture discharge and ventilation.

Model DR-19 DR-37 DR-72 DR-14 DR-28 DR-56

Power supply (V/ph/Hz) 380/3/50 380/3/51 380/3/52 380/3/53 380/3/54 380/3/55

Heating capacity (kw) 18,5 37 72 14 28 56

Power consumption (kw) 5,8 11,6 23,5 6,5 11,8 25,5

Air volume (M3 / h) 6000 12000 24000 6000 12000 24000

Refrigerant R417A R134A

Refrigerant weight (g) 4700 4700 x 2 4700 x 4 5200 5200 x 2 5200 x 4

Max. Power input (kw) 10,5 21 42,3 12 23,5 46

Max. Current (A) 18,5 37,5 75,5 21,5 42 82

Level against electric shock I I I I I I

Water-proof grade IPX4 IPX5 IPX6 IPX7 IPX8 IPX9

Net weight (kg) 155 270 622 175 320 720

Net size (mm) 800 x 800 x 1000 1200 x920 x 1255 2000 x 1100 x 1850 800 x 800 x 1150 1200 x 920 x 1455 2400 x 1130 x 2150

Water connection Φ12,7 / Φ19,5 Φ12,7 / Φ19,6 Φ12,7 / Φ19,7 Φ12,7 / Φ19,8 Φ12,7 / Φ19,9 Φ12,7 / Φ19,10

Operation temp. Range (C) -10~45 -10~46 -10~47 -10~48 -10~49 -10~50

Noise dB (A) ≤58 ≤60 ≤64 ≤64 ≤65 ≤68

Test condition Ambient temp. (DBv/WB): 20C / 150C, Output temp. : 450C Ambient temp. (DB/WB): 20C / 150C, Output temp. : 750C

Working Principle

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

28

HiCOP solar cell system is the latest power generation technology that uses solar cells (Photovoltaic) to convert sunlight into electrical energy.

Overview

Solar CellSystem

Specifications Hybrid (GW5048D-ES) On-Grid (GW2000-SS)

Max. DC power [W] 5400 2300Max. DC power [W] 580 500MPPT Voltage range [V] 125~550 125~450Starting Voltage [V] 125 125Max. DC current [A] 15/15 15No. Of DC connectors 2 1No. Of MPPTs 2 (can paraller) 1DC connector SUNCLIX/Mc4 (optional)

Battery

Battery type Lead-acid or Li-Ion -Battery voltage range [V] 46-60 -Max. Discharge power [W] 4600 -Charge current [A] 5-50 continous, programable -Battery capacity [Ah] 100~500 (depending requirement) -Charging curve 3 stage adaptive with maintenance -Battery temperature compensation Include Li-on -Battery voltage sense Integrated -Current Shunt Integrated -

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

28

29

SpecificationsElectric 200 Wp Temperature

Maximum Power 200 W Normal Operating Cell Tempera-ture (NOCT) 45 0C +/- 2 0C

Open Circuit Voltage (Voc) 45 V Temperature Coefficient of Pmax -0,44% 0C

Short Circuit Current (Isc) 5,8 Temperature Coefficient of Voc -0344% 0C

Maximum Power Voltage (Vmpp) 38,8 Temperature Coefficient of Isc 0,06% 0C

Maximum Power Current (Impp) 5,15

Module Efficiency 15,67%

Mechanical System Parameters

Dimension 1,580 mm x 800 mm x 35 mm Maximum System Voltage 1000 V

Frame Aluminium Alloy Series Fuse Rating 10A

Wight 15,5 Kg Operating Temperature -40 to + 85 0C

Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.

30

Hotel Fave Puri - Jakarta2 Unit Heat Pump HiCOP AW-21

Hotel Dafam - Bandung3 Unit Heat Pump HiCOP AW-21

Hotel Harris Yello - Jakarta5 Unit Heat Pump HiCOP AW-105

Hotel Ibis style - Bali2 Unit Heat Pump HiCOP AW-37

Hotel Mirah - Bogor1 Unit Heat Pump HiCOP AW-21

Hotel Moscato - Lembang4 Unit Heat Pump HiCOP AI-300

Hotel NEO - Bandung1 Unit Heat Pump HiCOP AW-10 & 1 Unit AW-21

Hotel Ozone - Jakarta3 Unit Heat Pump HiCOP AW-21

Hotel Harris Cisarua - Bogor1 Unit Heat Pump HiCOP AW-101 Unit Heat Pump HiCOP AW-201 Unit Heat Pump HiCOP AW-21

Hotel Golden Tulip - Pontianak2 Unit Heat Pump HiCOP AW-37

Hotel Fave - Malang City Point2 Unit Heat Pump HiCOP AW-41

Apartemen Pertamina - Balikpapan299 Unit Heat Pump HiCOP AI-100

Hotel Harris Tuban - Bali3 Unit Heat Pump HiCOP AW-21

Hotel Ibis Seminyak - Bali2 Unit Heat Pump HiCOP AW-37

Hotel Kuta Puri Bungalow - Bali2 Unit Heat Pump HiCOP AI-200

Hotel Oasis - Bandung1 Unit Heat Pump HiCOP AW-10

Hotel Nandya - Bandung2 Unit Heat Pump HiCOP AI-300

Hotel NEO - Jakarta2 Unit Heat Pump HiCOP AW-42

Hotel The Valley Dago - Bandung2 Unit Heat Pump HiCOP SP-393 Unit Heat Pump HiCOP AW-37

Hotel Petitenget - Bali6 Unit Heat Pump HiCOP AI-300

Project References

Hotel Quest - Balikpapan2 Unit Heat Pump HiCOP AW-21

Hotel Gunawaman - Jakarta2 Unit Heat Pump HiCOP AW-10

Hotel Promenade - Bali2 Unit Heat Pump HiCOP AW-37

Wisma BPJS - Puncak8 Unit Heat Pump HiCOP AI-300

30

31

RS. Banjarbaru - Banjarmasin3 Unit Heat Pump HiCOP AW-72

Villa Kharisma - Bali4 Unit Heat Pump HiCOP AI-300

Villa Ciwaruga - Bandung1 Unit Heat Pump HiCOP AI-300

Hotel The Kirana Canggu - Bali2 Unit Heat Pump HiCOP AW-21

Guest House 3S Pasteur - Bandung2 Unit Heat Pump HiCOP AI-300

The Groove Sport Station - Bandung2 Unit Heat Pump HiCOP SP-392 Unit Heat Pump HiCOP SP-17

Mekar Wangi Pool - Bandung1 Unit Heat Pump HiCOP AW-101 Unit Heat Pump HiCOP SP-17

Hotel Sahid Eminence - Ciloto4 Unit Heat Pump HiCOP AW-623 Unit Heat Pump HiCOP SP-62

Hotel M Ekspress - Sorong Papua1 Unit Heat Pump HiCOP AW-10

Hotel Sangria - Bandung1 Unit Heat Pump HiCOP AW-21

Setiabudi Regency - Bandung1 Unit Heat Pump HiCOP SP-39

Hotel Amaris - Yogyakarta2 Unit Heat Pump HiCOP AW-37

Hotel Best Westin - Jakarta5 Unit Heat Pump HiCOP SP-17

RS. H.S Budiman - Pangandaran1 Unit Heat Pump HiCOP AW-21

Hotel Fortune - Jakarta2 Unit Heat Pump HiCOP AW-211 Unit Heat Pump HiCOP SP-39

Villa Ultimo - Bali1 Unit Heat Pump HiCOP SP-201 Unit Heat Pump HiCOP SP-17

Hotel NEO - Yogyakarta2 Unit Heat Pump HiCOP AW-42

Terapi Pool Karapitan - Bandung1 Unit Heat Pump HiCOP AW-10

Hotel Premier Inn- Pontianak2 Unit Heat Pump HiCOP AW-37

Hotel Gunawarman - Jakarta2 Unit Heat Pump HiCOP AW-10

Waterboom Panghegar - Bandung2 Unit Heat Pump HiCOP SP-17

Martha Tilaar Spa - Jakarta2 Unit Heat Pump HiCOP AI-300

Zen Spa - Bali1 Unit Heat Pump HiCOP MFT-10

H Mansion - Jakarta1 Unit Heat Pump HiCOP AI-200

32

RSUP Prembun - Kebumen1 Unit Heat Pump HiCOP AW-10

Hotel Pemuda - Cirebon1 Unit Heat Pump HiCOP AW-21

Hotel Boabab Safari - Prigen3 Unit Heat Pump HiCOP AW-21

RS Fatmawati - Jakarta1 Unit Heat Pump HiCOP AW-21

Hotel Harper - Cikarang2 Unit Heat Pump HiCOP AW-371 Unit Heat Pump HiCOP SP-69

Hotel Swiss Bell Darmo Centrum - Surabaya3 Unit Heat Pump HiCOP AW-37

Hotel Ossotel - Bali2 Unit Heat Pump HiCOP SP-39

Hotel Amartya - Yogyakarta2 Unit Heat Pump HiCOP AW-37

Hotel Biz - Ambon3 Unit Heat Pump HiCOP AI-300

My Place SPA Jakarta2 Unit Heat Pump HiCOP SP-17

Wisma Kartika Astri - Jatinangor2 Unit Heat Pump HiCOP AW-21

RS Omni - Cikarang3 Unit Heat Pump HiCOP AW-42

Hotel Bunga-Bunga - Jakarta12 Unit Heat Pump HiCOP AI-300

PT. Arnott's Indonesia2 Unit Heat Pump HiCOP HT-58

Svarga Villa - Bali2 Unit Heat Pump HiCOP AI-2001 Unit Heat Pump HiCOP AI-300

RS Kasih Ibu - Bali2 Unit Heat Pump HiCOP AW-37

Hotel Grand Permata - Purwakarta3 Unit Heat Pump HiCOP AI-300

Hotel Art Deco - Bandung8 Unit Heat Pump HiCOP AW-21

Hotel Ibis - Bogor3 Unit Heat Pump HiCOP AW-42

Apartment Paviliun - Jakarta1 Unit Heat Pump HiCOP AI-200

Project References

Hotel Gracia Spa - Bandung1 Unit Heat Pump HiCOP AW-10

Hotel Swiss Bell - Jambi3 Unit Heat Pump HiCOP AW-21

32

33

RPH Farm - Garut2 Unit Heat Pump HiCOP HT-14

Hotel Maleo - Luwuk2 Unit Heat Pump HiCOP AW-21

RS. Halmahera - Bandung1 Unit Heat Pump HiCOP AW-10

Hotel Urban - Lampung2 Unit Heat Pump HiCOP AW-10

Hotel Sulis - Bali3 Unit Heat Pump HiCOP AW-21

RS Fatmawati - Jakarta1 Unit Heat Pump HiCOP AW-21

RSUD Cibitung3 Unit Heat Pump HiCOP AW-10

Hotel Amaris Hertasning - Makasar1 Unit Heat Pump HiCOP AW-21

Hotel Borobudur - Majenang1 Unit Heat Pump HiCOP AI-300

Hotel Grand Kesya - Yogyakarta2 Unit Heat Pump HiCOP AW-21

Hotel Grand Inna - Bali1 Unit Heat Pump HiCOP AW-72

Hotel Premier Inn - Yogyakarta2 Unit Heat Pump HiCOP AW-37

The Ungasan Cliftop Resort - Bali2 Unit Heat Pump HiCOP AI-200

Hotel Nyland - Bandung2 Unit Heat Pump HiCOP AW-21

Hotel Haniman - Bali2 Unit Heat Pump HiCOP AW-100

Hotel Fairfield - Bali3 Unit Heat Pump HiCOP AW-50

RSUD Tarakan - Jakarta2 Unit Heat Pump HiCOP AI-300

Villa Wanagiri - Bali1 Unit Heat Pump HiCOP SP-39

Hotel Gobleg - Bali1 Unit Heat Pump HiCOP SP-74

Hotel Fave - Tasikmalaya2 Unit Heat Pump HiCOP AW-21

Hotel Mexsolute - Kebumen7 Unit Heat Pump HiCOP AI-300

Hotel House Sangkuriang - Bandung1 Unit Heat Pump HiCOP AW - 21

34

Hotel Amaris Pettarani - Makasar2 Unit Heat Pump HiCOP AW-37

Hotel Aston - Belitung2 Unit Heat Pump HiCOP AW-42

Hotel Aston - Lampung2 Unit Heat Pump HiCOP AW-21

Hotel Aston Royal - Bekasi2 Unit Heat Pump HiCOP AW-21

Hotel Max One - Belitung2 Unit Heat Pump HiCOP AW-21

Hotel Fave - Bogor2 Unit Heat Pump HiCOP AW-37

Hotel Bali Mandira - Bali2 Unit Heat Pump HiCOP AW-21

Hotel Boulevard - Manado2 Unit Heat Pump HiCOP AW-10

Amaris Thamrin City - Jakarta2 Unit Heat Pump HiCOP AW-11

Hotel Mulia - Bali3 Unit Heat Pum HiCOP SP-39

Nusa Dua Convention Center - Bali2 Unit Heat Pump HiCOP AW-42

Hotel Amaris Teuku Umar - Bali2 Unit Heat Pump HiCOP AW-21

Hotel Aston - Bojonegoro3 Unit Heat Pump HiCOP AW-37

UPI - Bandung2 Unit Heat Pump HiCOP SP-69

Hotel Swissbell Tunjungan - Surabaya2 Unit Heat Pump HiCOP AW-37

The Groove Sport Station - Bandung3 Unit Heat Pump HiCOP SP-17

Hotel Salak - Bogor3 Unit Heat Pump HiCOP AW-37

Hotel Green Forest - Bogor2 Unit Heat Pump HiCOP AW-42

Hotel Kebayoran Icon - Jakarta2 Unit Heat Pump HiCOP AW-37

RS. Samarinda1 Unit Heat Pump HiCOP AW-21

RS. Atmajaya - Jakarta3 Unit Heat Pump HiCOP AW-37

Hotel Britz Karawang2 Unit Heat Pump HiCOP AW-21

Hotel POP Pasar Baru - Jakarta2 Unit Heat Pump HiCOP AW-21

Hotel Intan - Jakarta3 Unit Heat Pump HiCOP AW-21

Project References

34

35

Hotel Royal Olive - Jakarta2 Unit Heat Pump HiCOP AW-37

Hotel Harris - Pontianak2 Unit Heat Pump HiCOP AW-21

Hotel Sala View - Solo2 Unit Heat Pump HiCOP AW-21

Hotel Santika - Cikarang2 Unit Heat Pump HiCOP AW-21

Hotel Swiss Belinn - Singkawang3 Unit Heat Pump HiCOP AW-37

Hotel Sultan Raja - Cirebon2 Unit Heat Pump HiCOP AW-35

Hotel Sultan Raja - Palu3 Unit Heat Pump HiCOP AI-200

Hotel Swiss Bell Borneo - Banjarmasin2 Unit Heat Pump HiCOP AW-37

U Residence - Jakarta5 Unit Heat Pump HiCOP AI-200

Hotel Triple 7 - Pajajaran1 Unit Heat Pump HiCOP AW-10

Hotel Wibowo - Semarang1 Unit Heat Pump HiCOP AI-300

Hotel Dafam Lotus - Jember2 Unit Heat Pump HiCOP AW-21

Hotel Urban - Lampung2 Unit Heat Pump HiCOP AW-10

Hotel El Banyuwangi2 Unit Heat Pump HiCOP AW-21

Hotel Sulis - Kuta, Bali 3 Unit Heat Pump HiCOP AW-21 Titanium

Hotel Matraman - Jakarta3 Unit Heat Pump HiCOP AW-90

Hotel Illira - Banyuwangi2 Unit HiCOP Pressure Tank 2000L

RSUD Bogor2 Unit Heat Pump HiCOP AW-37

RS Hermina - Jakarta2 Unit HiCOP Pressure Tank 3500L

PT. Afiat PharmaCeutical - Bandung1 Unit Heat Pump HiCOP AI-300

Hotel Norwood - Jakarta2 Unit Heat Pump HiCOP AW-10

UPI - Serang3 Unit Heat Pump HiCOP AW-10

Hotel Blackbird - Bandung1 Unit Heat Pump HiCOP AW-21

RS. Provinsi Bali2 Unit Heat Pump HiCOP AW-37

36www.hicop.co.id

25112016