Upload
others
View
8
Download
1
Embed Size (px)
Citation preview
Presentation name (update in Slide Master) 1
Copeland Hermetic Recip A*E CompressorsLocation, Date
DOE/EPARegulations Update2/17/2017
Presentation name (update in Slide Master) 33Presentation name (update in Slide Master)
Commercial Refrigeration Equipment Equipment Classes
Source: Department of Energy
Low- or Medium-Temperature
Vertical, Semi-Vertical, Horizontal or Service
Over Counter
Self-Contained or Remote Condensing
With or Without Solid/Transparent Doors
Commercial Refrigerator and Freezer
33+ Classes of Equipment20+ Sizes/Eqp. Class
Equi
pmen
t Affe
cted Buffet Tables, Salad Bars, Prep Tables Not Affected
Depending Upon Refrigeration Construction
Presentation name (update in Slide Master) 44Presentation name (update in Slide Master)
Buffet Tables, Salad Bars, Prep Tables BeyondScope of Energy Mandates
Source: Department of Energy
RegulatedTop Rail
BottomStorage
Regulated Regulated Not Regulated
Presentation name (update in Slide Master) 55Presentation name (update in Slide Master)
CRE Equipment DOE Analysis and Equations
Source: Department of Energy
• X-axis: size of equipment ft3• Y-axis: energy draw kWh/day• Equation format: Y = m(x) + b• kWh = m(ft3) + b
• 33 classes of equipment• Remote condensing and self-contained open
cases will not require major efficiency improvement challenges
• Self-contained vertical reach-ins will require significant efficiency improvement changes
2010 2012 2017 2010 2012 2017 % Delta 2010 2012 2017 % DeltaVOP.RC.M 0.82 x TDA + 4.07 0.64 x TDA + 4.07 4.07 4.07 0% 0.82 0.64 -22%VOP.RC.L 2.27 x TDA + 6.85 2.2 x TDA + 6.85 6.85 6.85 0% 2.27 2.2 -3%SVO.RC.M 0.83 x TDA + 3.18 0.66 x TDA + 3.18 3.18 3.18 0% 0.83 0.66 -20%SVO.RC.L 2.27 x TDA + 6.85 2.2 x TDA + 6.85 6.85 6.85 0% 2.27 2.2 -3%HZO.RC.M 0.35 x TDA + 2.88 0.35 x TDA + 2.88 2.88 2.88 0% 0.35 0.35 0%HZO.RC.L 0.57 x TDA + 6.88 0.55 x TDA + 6.88 6.88 6.88 0% 0.57 0.55 -4%VCT.RC.M 0.22 x TDA + 1.95 0.15 x TDA + 1.95 1.95 1.95 0% 0.22 0.15 -32%VCT.RC.L 0.56 x TDA + 2.61 0.49 x TDA + 2.61 2.61 2.61 0% 0.56 0.49 -13%HCT.RC.M 0.16 x TDA + 0.13 0.16 x TDA + 0.13 0.13 0.13 0% 0.16 0.16 0%HCT.RC.L 0.34 x TDA + 0.26 0.34 x TDA + 0.26 0.26 0.26 0% 0.34 0.34 0%VCS.RC.M 0.11 x V + 0.26 0.1 x V + 0.26 0.26 0.26 0% 0.11 0.1 -9%VCS.RC.L 0.23 x V + 0.54 0.21 x V + 0.54 0.54 0.54 0% 0.23 0.21 -9%HCS.RC.M 0.11 x V + 0.26 0.1 x V + 0.26 0.26 0.26 0% 0.11 0.1 -9%HCS.RC.L 0.23 x V + 0.54 0.21 x V + 0.54 0.54 0.54 0% 0.23 0.21 -9%SOC.RC.M 0.51 x TDA + 0.11 0.44 x TDA + 0.11 0.11 0.11 0% 0.51 0.44 -14%SOC.RC.L 1.08 x TDA + 0.22 0.93 x TDA + 0.22 0.22 0.22 0% 1.08 0.93 -14%VOP.SC.M 1.74 x TDA + 4.71 1.69 x TDA + 4.71 4.71 4.71 0% 1.74 1.69 -3%VOP.SC.L 4.37 x TDA + 11.82 4.25 x TDA + 11.82 1.82 1.82 0% 4.37 4.25 -3%SVO.SC.M 1.73 x TDA + 4.59 1.7 x TDA + 4.59 4.59 4.59 0% 1.73 1.7 -2%SVO.SC.L 4.34 x TDA + 11.51 4.26 x TDA + 11.51 1.51 1.51 0% 4.34 4.26 -2%HZO.SC.M 0.77 x TDA + 5.55 0.72 x TDA + 5.55 5.55 5.55 0% 0.77 0.72 -6%HZO.SC.L 1.92 x TDA + 7.08 1.9 x TDA + 7.08 7.08 7.08 0% 1.92 1.9 -1%VCT.SC.M 0.12 V + 3.34 0.1 x V + 0.86 3.34 0.86 -74% 0.12 0.1 -17%VCT.SC.L 0.75 V + 4.10 0.29 x V + 2.95 4.1 2.95 -28% 0.75 0.29 -61%VCS.SC.M 0.10 V + 2.04 0.05 x V + 1.36 2.04 1.36 -33% 0.10 0.05 -50%VCS.SC.L 0.40 V + 1.38 0.22 x V + 1.38 1.38 1.38 0% 0.40 0.22 -45%
Equations y-Intercept Slope
Presentation name (update in Slide Master) 66Presentation name (update in Slide Master)
Status of U.S. Refrigeration Energy Regulations
Compliance Effective Dates Are Nearing.
Product Class Current NOPR Final Effective Energy Level Reduction
U.S
. Dep
artm
ent o
f Ene
rgy
Closed-DoorsReach-Ins
(Self-Contained)2010 Oct. 2013 March 2014*
March 2017(FINAL)
kWh/Day30%–50%
Ice Makers 2010NODA
Sept. 2014Jan. 2015
Jan. 2018(FINAL)
kWh/100 lbs5%–15%
Display Cases,Including Remote
2012 Oct. 2013 March 2014*March 2017
(FINAL)kWh/Day
30%–50%
Walk-In(Foodservice)
2009 Sept. 2013
Jan. 2016**No change MT;
No change panels
and doors;LT and multiplex
out of cmte.
Jan. 2020(all enforced)
AWEFMT 20%–40%;
LT and Multiplex 20–30%(ASRAC Cmte. Proposal)
* Lawsuit filed by industry in 7th Circuit Court; Petition denied, final rule stays** Lawsuit filed by industry in 5th Circuit Court; settlement reached July 2015 to refer to ASRAC Cmte., with cmte. to make proposal in January 2016, which they met. Awaiting DOE and Court final approvals.
Presentation name (update in Slide Master) 77Presentation name (update in Slide Master)
EPA’s Final Rule, July 20, 2015, and September 26,2016Changed listing status of certain HFCs*
Final Rule: July 20, 2015 Final Rule: September 26, 2016
Phase-outrefrigerant
Super-market(New**)
Super-market
(Retrofit***)
Remote condensin
g unit(New)
Remote condensing
unit(Retrofit***)
Stand-Alone Refrigerated food
processing and
dispensingequipment
(New)
Cold storage
warehouses (New)
Ice machines
(New)
Very low-temp
refrigeration(New)
MT < 2,200 BTU/hr. and not contain flooded
evap. (New)
MT ≥ 2,200 BTU/hr. with or without flooded
evap. (New)
LT(New)
LT and MT(Retrofit***)
R-404A/507A Jan. 1, 2017 July 20,
2016 Jan. 1, 2018 July 20,2016 Jan. 1, 2019 Jan. 1, 2020 Jan. 1, 2020 July 20,
2016 Jan. 1, 2021 ^Jan. 1, 2023 OK OK
R-410A OK - OK - Jan. 1, 2019 Jan. 1, 2020 Jan. 1, 2020 - Jan. 1, 2021 ^Jan. 1, 2023 OK OK
R-407A/C/F OK OK OK OK Jan. 1, 2019 Jan. 1, 2020 Jan. 1, 2020 OK ^Jan. 1, 2021R-407C/F OK
R-407A:^Jan. 1, 2023
OK R-407C only
HFC-134a OK OK OK OK Jan. 1, 2019 Jan. 1, 2020 OK OK OK OK OK -
Likely alternatives(Emerson perspective)
R-448A/449A OK OK OK OK Neither SNAP-
approved, nor bannedNeither SNAP-
approved, nor banned OK OK forLT only - - OK -
R-450A/513A OK OK OK OK OK OK OK OK OK OK OK -
R-290 - - - - OK OK OK - - - OK OK
R-744 OK - OK - OK OK OK - OK OK - OK
R-717OK
(in primary loop of secondary system)
-OK
(In primary loop of secondary system)
-OK
(in primary loop ofsecondary system)
OK(in primary loop ofsecondary system)
OK(in primary loop ofsecondary system)
OK(in primary loop ofsecondary system)
OK(in primary loop ofsecondary system)
OK OK -
** Includes ice machines connected to a supermarket rack refrigeration system.*** EPA uses term “retrofit” to indicate the use of a refrigerant in an appliance that was designed for and originally operated using a different refrigerant.
Term does not apply to upgrades to existing equipment where the refrigerant is not changed.
*Abbreviated – For complete listing, see EPA Final Rule; go to: https://www.gpo.gov/fdsys/pkg/FR-2015-07-20/pdf/2015-17066.pdf
See proposed rule; go to: https://www.gpo.gov/fdsys/pkg/FR-2016-04-18/pdf/2016-08163.pdf
Presentation name (update in Slide Master) 88Presentation name (update in Slide Master)
Current State of Refrigerant OptionsLow-GWP alternatives are flammable or high-pressure
Watch: EPA SNAP, AHRI’s A2L Research, Standards and Code Committees, Equipment Manufacturers’ New Product Launches
Presentation name (update in Slide Master) 99Presentation name (update in Slide Master)
Compliance Will Not Be Easy
Opportunity to Comply With One Design Cycle Change
EPA Refrig.
DOE Energy
EnergyEnvironment
EconomicsEquipment
Launch of Next Gen A Compressors
Presentation name (update in Slide Master) 11
Copeland Hermetic Recip next Gen A*E CompressorsTargets Customer Requirements To Meet DOE and EPA
C5E & AFF
Presentation name (update in Slide Master) 12
Copeland Hermetic Recip next Gen A*E Compressor –Program Targets & Scope
Program Targets• Improved Efficiency – Up to 25% more EER• Similar Sound Levels• Match existing reliability • Same mounting• Dimensionally similar or smaller than current• Alternative refrigerant approved• Manufactured In Slovakia and Brazil• Match existing delivery lead times• UL and CE approved• In metro approval on a few models (AFF)
Scope• Covers 1/8–3/4 HP Low, Medium and High Temp models• LT Range: 500 Btu to 2600 Btu• MT Range: 1200 Btu to 4500 Btu• HT Range: 1300 Btu to 5400 Btu• Covers all current voltage options (options differs my model. Check line up chart)1
–115V 60Hz & 115-127V 60Hz (IAA & CAA)–208-230V 60Hz, 220V 60Hz (IAV, CAV & IA3)–220-240V 50Hz, 200-240V 50Hz (IAZ, CAZ and IAB)
Presentation name (update in Slide Master) 13
Next Gen A Covers Most Commercial Refrigeration Applications
Wide Voltage Range Guarantees that the equipment will run even with voltage fluctuation.
Verticalfreezers
IslandCoolers
BottleCoolers
VendingMachines
DisplayCases
Reach-ins Icemakers
300lto 600l
Up to 3m 500lto 600l
Up to 800l 300lto 1000l
300lto 500l
Up to200 kg/day
Presentation name (update in Slide Master) 14
Copeland Hermetic Recip Next Gen A*EToday vs Future
Today’s Platforms Future Platforms
A*E**C3E Compressors(Phasing Out)
A*E**C4E Compressors
(Not phasing out but some models will have
C5E/AFF crosses as options for DOE)
Same FootprintBetter SoundHigher EfficiencyAlt. Ref. Availability
1
2
3
4
A*E**C4E Compressors
A*E**C5E Compressors(Phasing In)
AFF**C1E Compressors(Phasing In)
Presentation name (update in Slide Master) 15
Next Gen A*E CompressorsSame Footprints
A*E**c5E (vs C3E/C4E) AFF**C1E (vs C3E/C4E)
Semi direct suctionSame tube location
Same tube sizesSame overall dimension
Same mountingOptimized Motors For Efficiency
Semi direct suctionSimilar tube sizes
Flipped Discharge/Suction Tube LocationSmaller overall dimension
Similar mountingOnly R134a (and R513A, R450A)
Ext. Medium Temp Envelope
1
Presentation name (update in Slide Master) 1616Presentation name (update in Slide Master)
Next Gen A CompressorsSound Reduced Design
C4E/C5E shows comparable sound level compared to C3EAFF has about 15-20% lower sound level compared to C3E
0
10
20
30
40
50
60
70
C3E C4E C5E AFF
Sound Power Avg dBA Sound Power Max dBA
15-20%Sound
Delta vs C3E
Comparable to C3E
Comparable to C3E
2
Presentation name (update in Slide Master) 17
Next Gen A*E CompressorsHigher Efficiency
3
R134a | Low Temp | -10/110 °F
R404A | Low Temp | -10/110 °F
R134a | High Temp | 45/130 °F
R404A | Medium Temp | 20/120 °F
0
1.5
3
4.5
AFE12C3E AFE12C4E AFF10C1E3
4.5
6
7.5
ARE37C3E ARE34C4E ARE35C5E
0
1.5
3
4.5
AFE13C3E AFE13C4E AFE14C5E0
1.5
3
4.5
ASE24C3E ASE26C4E ASE24C5E
Presentation name (update in Slide Master) 18
Next Gen A*E CompressorsAFF can be used in MT applications
3
R134a | MT | 20/120 °F R134a | MT | 20/120 °F
3
4.5
6
7.5
ARE27C3E AFF07C1E
ARE27C3E AFF07C1E
3
4.5
6
7.5
ARE29C4E AFF08C1E
ARE29C4E AFF08C1E
Presentation name (update in Slide Master) 19
Capacity EER
C3E vs C5E Performance Curve ComparisonASE24C3E vs ASE24C5E
3
0
500
1000
1500
2000
2500
3000
3500
4000
-15 -5 5 15 25 35
BTU
/Hr
Evap
0
1
2
3
4
5
6
7
-15 -5 5 15 25 35
EER
Evap
ASE24C3E
ASE24C5E
Presentation name (update in Slide Master) 2020Presentation name (update in Slide Master)
C3E vs C5E Performance Curve ComparisonASE24C3E vs ASE24C5E
3
Capacity EER
0
500
1000
1500
2000
2500
3000
3500
4000
-15 -5 5 15 25 35
BTU
/Hr
Evap
0
1
2
3
4
5
6
7
-15 -5 5 15 25 35
EER
Evap
ASE24C3E
ASE24C5E
Capacity and EER curves almost parallel across the evap. range
Presentation name (update in Slide Master) 2121Presentation name (update in Slide Master)
C3/C4/C5 vs AFF Performance Curve ComparisonAFE13C5E vs AFF13C1E
3
Capacity EER
0
500
1000
1500
2000
2500
3000
-30 -20 -10 0 10 20
BTU
/Hr
Evap0
1
2
3
4
5
6
-30 -20 -10 0 10 20
BTU
/Hr
Evap
AFF13C1E-IAAAFE13C5E-IAA
Capacity and EER curves almost parallel across the evap. range
Presentation name (update in Slide Master) 2222Presentation name (update in Slide Master)
Next Gen A*E CompressorsAlternate Refrigerant Availability
4
R404A(GWP 3922)
R448A(GWP 1273)
R449A(GWP 1282)
R134a(GWP 1430)
R450A(GWP 547)
R513A(GWP 573)
AFE * Under Eval. Under Eval.
AFF NA NA NA Under Eval. Under Eval.
ASE * NA NA NA
ARE * NA NA NA Under Eval. Under Eval.
* Only C4E, C5E and AFF compressors approved or planned for approval. C3E are not in the plan for approval.
Dew-Point Tested Refrigerant Comparison (Primary Rating Points, 0F Subcooling)
Refrigerant GWPPressure
(psia) @130F
LT Evap EER
LT Evap Cap
DischTemp **(-10/120)
MT Evap EER
MT Evap Cap
DischTemp ** (20/120)
HT Evap EER
HT Evap Cap
DischTemp** (45/130)
Glide (@120F)
R134a 1430 213.4 100% 100% 170 - - - 100% 100% 197 0R450A (N13) 547 186.5 99% 86% 166 - - - 101% 88% 194 7.62
R513A (XP10) 573 221.7 100% 109% 174 - - - 96% 100% 182 4.65
R404A 3922 368.2 100% 100% 229 100% 100% 174 - - - 0.52R448A (N40) 1273 343.2 109% 94% 244 109% 97% 187 - - - 7.81R449A (XP40) 1282 343.3 109% 94% 244 109% 97% 187 - - - 7.70
** Discharge Temperatures Are Based Off Comparable Tested Data with AFF_C1E-IAA, RFT42C1E-CAA, RST45C1E-CAA, and ARE34C4E-IAA
C4/C5: R448A/R449A are approved. R450A/R513A will be approved Dec’16AFF: R450A/R513A will be approved in Jan’17
Presentation name (update in Slide Master) 23
0-1 FHP Hermetic Recip Product Line-UpPhase In and Phase Out
HP 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0MT Cap 0.75 1.5 2.25 3 3.75 4.5 5.25 6 6.75 7.5
LT Cap 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0
kBTU/hrWith Primary Refr. (404A, 134a)
A*E
R*T
A*E**C4E
A*E**C3E
A*E**C5EAFF**C1E
Phasing Out
Existing Model. Staying In The Line Up
Phasing In
R*T**C1E
Existing Model. Staying In The Line Up
Presentation name (update in Slide Master) 2424Presentation name (update in Slide Master)
Next Gen A*E Compressor Line UpEnvironment
Energy
AFE05
AFE06AFE08
AFE11
AFE12
AFE13C4
AFE13C5
AFE14
AFE17
AFE20
AFE23 AFE26
AFF07
AFF08 AFF10AFF13
ASE24ASE12 ASE14 ASE20 ASE28ASE26 ASE32 ASE39ASE35 ASE45
ARE13 ARE17 ARE25C4ARE25C5ARE29 ARE34 ARE35 ARE40 ARE42
ARE48 ARE51 ARE54
0 1000 2000 3000 4000 5000 6000
60Hz Models Capacity in Btu/hr
AFE08 AFE11
AFE12 AFE13
AFE14 AFE17
AFE20
AFE23AFE26
AFF10 AFF13
ASE20 ASE24 ASE26 ASE28 ASE32 ASE39 ASE45
ARE25 ARE29 ARE34 ARE42 ARE48 ARE51 ARE54
0 1000 2000 3000 4000 5000 6000
50Hz Models Capacity in Btu/hr
1/4th HP to 3/4th HP A*E compressor line up available both in 50Hz and 60Hz covering all Low, Medium, and High Temp applications
1/4th HP to 3/4th HP A*E compressor line up available both in 50Hz and 60Hz covering all Low, Medium, and High Temp applications
LT
MT
LT
MT
HT
HT
Presentation name (update in Slide Master) 2525Presentation name (update in Slide Master)
Next Gen A CompressorsLow Temp Models
Models Refrigerants
Voltage OfferingIAA CAA IAV CAV IAZ CAZ IAB CAB
60Hz 60Hz 60Hz 60Hz 50Hz 50Hz 50/60Hz 50/60Hz
115V or 115-127V 115V or 115-127V 208-230V 208-230V200-230V or 200-
240V200-230V or 200-
240V230V 60Hz or 200-
240V 50Hz230V 60Hz or 200-
240V 50HzAFE05C4E R134a, R513A, R450A
AFE06C4E R404A, R448A, R449A
AFE08C4E R404A, R448A, R449A
AFE11C4E R404A, R448A, R449A
AFE12C4E R134a, R513A, R450A
AFE13C4E R404A, R448A, R449A
AFE13C5E R134a, R513A, R450A
AFE14C5E R404A, R448A, R449A
AFE17C4E R404A, R448A, R449A
AFE20C5E R404A, R448A, R449A
AFE23C5E R404A, R448A, R449A
AFE26C5E R404A, R448A, R449A
ReleasedIn ProgressNot Offering
All R404A models are qualified for R448A/R449AAll R134a models are qualified for R450A/R513A
Presentation name (update in Slide Master) 2626Presentation name (update in Slide Master)
All R134 models are qualified for R450A/R513A
Next Gen A CompressorsExtended Medium Temp Models
Models Refrigerants
Voltage OfferingIAA CAA IA3 CAV IAZ CAZ IAB CAB
60Hz 60Hz 60Hz 60Hz 50Hz 50Hz 50/60Hz 50/60Hz
115V or 115-127V 115V or 115-127V 220V 208-230V200-230V or 200-
240V200-230V or 200-
240V230V 60Hz or 200-
240V 50Hz230V 60Hz or 200-
240V 50HzAFF07C1E R134a, R513A, R450A
AFF08C1E R134a, R513A, R450A
AFF10C1E R134a, R513A, R450A
AFF13C1E R134a, R513A, R450A
ReleasedIn ProgressNot Offering
Presentation name (update in Slide Master) 2727Presentation name (update in Slide Master)
Next Gen A CompressorsMedium Temp Models
Models Refrigerants
Voltage OfferingIAA CAA IAV CAV IAZ CAZ IAB CAB
60Hz 60Hz 60Hz 60Hz 50Hz 50Hz 50/60Hz 50/60Hz
115V or 115-127V 115V or 115-127V 208-230V 208-230V200-230V or 200-
240V200-230V or 200-
240V230V 60Hz or 200-
240V 50Hz230V 60Hz or 200-
240V 50HzASE12C4E R404A, R448A, R449A
ASE14C4E R404A, R448A, R449A
ASE20C4E R404A, R448A, R449A Dec' 2017
ASE20C5E R404A, R448A, R449A
ASE24C5E R404A, R448A, R449A Dec' 2017 Dec' 2017
ASE26C4E R404A, R448A, R449A
ASE28C5E R404A, R448A, R449A
ASE32C5E R404A, R448A, R449A
ASE35C4E R404A, R448A, R449A
ASE39C5E R404A, R448A, R449A
ASE45C5E R404A, R448A, R449A
ReleasedIn ProgressNot Offering
All R404A models are qualified for R448A/R449A
Presentation name (update in Slide Master) 2828Presentation name (update in Slide Master)
Next Gen A CompressorsHigh Temp Models
Models Refrigerants
Voltage OfferingIAA CAA IAV CAV IAZ CAZ IAB CAB
60Hz 60Hz 60Hz 60Hz 50Hz 50Hz 50/60Hz 50/60Hz
115V or 115-127V 115V or 115-127V 208-230V 208-230V200-230V or 200-
240V200-230V or 200-
240V230V 60Hz or 200-
240V 50Hz230V 60Hz or 200-
240V 50HzARE13C4E R134a, R513A, R450A
ARE17C4E R134a, R513A, R450A
ARE25C4E R134a, R513A, R450A
ARE25C5E R134a, R513A, R450A
ARE29C4E R134a, R513A, R450A Oct' 2017ARE34C4E R134a, R513A, R450A
ARE35C5E R134a, R513A, R450A
ARE40C4E R134a, R513A, R450A
ARE42C5E R134a, R513A, R450A
ARE48C5E R134a, R513A, R450A
ARE51C4E R134a, R513A, R450A
ARE54C5E R134a, R513A, R450A
ReleasedIn ProgressNot Offering
All R134 models are qualified for R450A/R513A
Presentation name (update in Slide Master) 2929Presentation name (update in Slide Master)
The New AFF Platform
The AFF delivers higher performance at Low and Medium Temp R134a Applications
• The AFF**C1E compressor platform is a new high efficiency compressor platform manufactured in Brazil
• The compressor platform delivers significant improvement in reliability over existing compressors
• It is primarily a replacement for the LT R134a compressors but can be effectively applied in MT R134a Reach In applications if used within the envelope
-34 -29 -23 -18 -12 -7 -1 4 10 16
16
21
27
32
38
43
49
54
60
66
60
70
80
90
100
110
120
130
140
150
-30 -20 -10 0 10 20 30 40 50 60
Evaporating Temp, °C
Con
dens
ing
Tem
p, °C
Con
dens
ing
Tem
p, °F
Evaporating Temp, °F
AFF ARE
Presentation name (update in Slide Master) 30
Copeland hermetic Next Gen A*E Compressors –BOM Guidelines
SE Suction Fitting Description
-201 BrazeOEM Standard Production Model With All Electrical Components (Protector & Capacitors & Relay) and Mounting Grommets and Sleeves
-202 Braze OEM (Protector and Terminal Cover Only)
-251, -252, -282 Braze Other OEM-Specific BOMs Less Warranty (By Request)
-301 (no AFF) BrazeOEM Pre-Pack OEM Standard Production Model With All Electrical Components (Protector & Capacitors & Relay) and Mounting Grommets and Sleeves
-302 (no AFF) Braze OEM Pre-Pack (Protector and Terminal Cover Only)
-303 (no AFF) BrazeOther Pre-Pack OEM Standard Production Model With All Electrical Components (Protector & Capacitors & Relay) and Mounting Grommets and Sleeves Bulk Packed
-7xx Braze Service Compressors Sold to OEM Customers
-901 Braze Service Compressor Like -201
-959 Service Valve Service Compressor Like 201 with Conduit
Additional InformationPerformance Details of the Next Gen A Line UpC3E Compressor Crosses to Next Gen AOperating Envelope Charts (LT, EMT, MT, HT)Drawing Cross Reference (C3/C4-> C5 & C3/C4-> AFF)Ratings on CPID and OPIHermetic Nomenclature Guideline
Presentation name (update in Slide Master) 32
Next Gen A CompressorsLT R134a/R404A @ -10/120 °F ARI
Application Model Line Up Capacity EERAccepting
Production Orders
Low Temp
AFE05C4E-IAA 584 3.09 NowAFE06C4E-IAA 577 2.49 NowAFE08C4E-IAA 720 2.61 NowAFE08C4E-IAZ 571 2.68 NowAFE11C4E-IAA 980 3.16 NowAFE11C4E-IAV 980 3.16 NowAFE11C4E-IAZ 794 3.00 NowAFE12C4E-IAA 1325 3.21 NowAFE12C4E-IAZ 1090 3.21 NowAFE13C4E-IAA 1330 3.14 NowAFE13C4E-IAV 1270 2.90 NowAFE13C4E-IAZ 1080 3.10 NowAFE13C5E-CAA 1,380 3.50 NowAFE13C5E-IAA 1,370 3.30 NowAFE14C5E-CAA 1,410 3.60 NowAFE14C5E-IAA 1,400 3.40 NowAFE14C5E-IAV 1,400 3.40 NowAFE14C5E-IAZ 1,160 3.40 NowAFE17C4E-CAA 1740 3.22 NowAFE17C4E-IAA 1700 2.98 NowAFE17C4E-IAV 1620 2.77 NowAFE17C4E-IAZ 1560 3.16 NowAFE20C5E-CAA 1,920 3.60 NowAFE20C5E-CAV 1,920 3.60 NowAFE20C5E-IAA 1,900 3.40 NowAFE20C5E-IAV 1,900 3.40 NowAFE20C5E-IAZ 1,580 3.40 NowAFE23C5E-CAA 2,280 3.50 NowAFE23C5E-CAV 2,280 3.50 NowAFE23C5E-CAZ 1,895 3.50 NowAFE26C5E-CAA 2570 3.39 NowAFE26C5E-CAV 2,570 3.40 NowAFE26C5E-CAZ 2,140 3.40 Now
R448A/R449A/R450A/R513A data also available on OPI
Presentation name (update in Slide Master) 33
Next Gen A CompressorsExt. MT R134a @ -10/120 °F ARI
Application Model Line Up Capacity EERAccepting
Production Orders
Low Medium Temp
AFF07C1E-IAA 682 4.30 NowAFF08C1E-IAA 832 4.07 NowAFF10C1E-IAA 1070 4.10 NowAFF10C1E-IA3 1070 3.95 NowAFF10C1E-IAZ 889 4.05 NowAFF13C1E-IAA 1250 3.95 NowAFF13C1E-IA3 1350 4.05 NowAFF13C1E-IAZ 1105 4.00 Now
R450A/R513A data also available on
OPI
Presentation name (update in Slide Master) 34
Next Gen A CompressorsMedium Temp. R404A @ -20/120 °F ARI
Application Model Line Up Capacity EERAccepting Production
Orders
Medium Temp
ASE12C4E-IAA 1355 4.37 NowASE14C4E-IAA 1645 4.24 NowASE20C4E-CAA 2080 4.58 NowASE20C4E-IAA 2080 4.36 NowASE20C4E-IAV 2160 4.50 NowASE20C4E-IAZ 1760 4.45 Dec’ 17ASE24C5E-CAA 2,300 5.00 NowASE24C5E-IAA 2,280 4.70 NowASE24C5E-IAV 2280 4.72 Dec 17ASE24C5E-IAZ 1,900 4.70 Dec’ 17ASE26C4E-CAA 2720 4.86 NowASE26C4E-IAA 2650 4.53 NowASE26C4E-IAZ 2250 4.89 NowASE28C5E-CAA 2,810 5.20 NowASE28C5E-CAV 2,800 5.00 NowASE28C5E-IAA 2,760 4.80 NowASE28C5E-IAV 2760 4.80 NowASE28C5E-IAZ 2308 4.66 NowASE32C5E-CAA 3328 5.32 NowASE32C5E-CAV 3328 5.32 NowASE32C5E-CAZ 2773 5.32 NowASE32C5E-IAA 3260 4.80 NowASE32C5E-IAV 3260 4.80 NowASE32C5E-IAZ 2716 4.80 NowASE35C4E-CAA 3600 4.44 NowASE35C4E-IAA 3520 4.05 NowASE39C5E-CAA 3,840 4.70 NowASE39C5E-CAV 3840 4.70 NowASE39C5E-CAZ 3200 4.70 NowASE39C5E-IAA 3840 4.50 NowASE39C5E-IAV 3890 4.55 NowASE39C5E-IAZ 3240 4.55 NowASE45C5E-CAA 4527 4.82 NowASE45C5E-CAV 4550 4.75 NowASE45C5E-CAZ 3773 4.82 Now
R448A/R449A data also available on
OPI
Presentation name (update in Slide Master) 35
Next Gen A CompressorsHigh Temp. R404A @ 45/130 °F ARI
Application Model Line Up Capacity EERAccepting Production
Orders
High Temp
ARE13C4E-IAA 1480 6.02 NowARE17C4E-IAA 1830 6.25 NowARE25C4E-IAA 2540 7.04 NowARE25C4E-IAV 2490 6.75 NowARE25C4E-IAZ 2150 7.20 NowARE25C5E-CAA 2,950 8.90 NowARE25C5E-IAA 2,910 8.25 NowARE29C4E-IAA 2920 6.79 NowARE29C4E-IAZ 2500 7.00 Dec’ 17ARE34C4E-IAA 3380 6.76 NowARE34C4E-IAV 2960 7.10 NowARE34C4E-IAZ 2910 7.00 NowARE35C5E-CAA 3,640 7.40 NowARE35C5E-IAA 3,590 7.00 NowARE35C5E-IAB 2,990 7.00 NowARE40C4E-IAA 4000 6.45 NowARE42C5E-CAA 4440 7.20 NowARE42C5E-CAV 4440 7.20 NowARE42C5E-CAZ 3700 7.20 NowARE42C5E-IAA 4173 6.66 NowARE42C5E-IAV 4173 6.67 NowARE42C5E-IAZ 3478 6.66 NowARE48C5E-CAA 4,920 7.10 NowARE48C5E-CAZ 3,900 6.00 NowARE48C5E-CAV 4,920 7.10 NowARE48C5E-IAA 4,830 6.40 NowARE48C5E-IAZ 4100 6.44 NowARE48C5E-IAV 4,830 6.40 NowARE51C4E-CAA 5220 6.03 NowARE51C4E-IAV 4940 5.49 NowARE51C4E-IAZ 4370 5.68 NowARE54C5E-CAA 5580 6.56 NowARE54C5E-CAV 5580 6.56 NowARE54C5E-CAZ 4650 6.57 NowARE54C5E-IAA 5,510 6.10 NowARE54C5E-IAV 5,510 6.10 NowARE54C5E-IAZ 4591 6.10 Now
R450A/R513A data also available on
OPI
Presentation name (update in Slide Master) 3636Presentation name (update in Slide Master)
Next Gen A CompressorsC3E Compressor Crosses (R404A->R404A & R134a->R134a crosses)
C3E Model Application Capacity EERNext Gen Model Cross Capacity EER Delta Cap Delta EER
AFE07C3E-IAA R-134a - LT (-10°F/120°F) 710 3.09 AFF07C1E-IAA 682 4.29 -3.9% 38.8%AFE10C3E-IAA R-134a - LT (-10°F/120°F) 936 3.09 AFF10C1E-IAA 1069 4.09 14.2% 32.4%AFE11C3E-IAA R-404A - LT (-10°F/120°F) 984 2.6 AFE11C4E-IAA 980 3.16 -0.4% 21.5%AFE11C3E-IAV R-404A - LT (-10°F/120°F) 984 2.6 AFE11C4E-IAV 980 3.16 -0.4% 21.5%AFE11C3E-IAZ R-404A - LT (-10°F/120°F) 810 2.57 AFE11C4E-IAZ 817 3.16 0.8% 23.0%AFE12C3E-IAA R-134a - LT (-10°F/120°F) 1130 3.25 AFF10C1E-IAA 1069 4.1 -5.3% 26.2%AFE12C3E-IAZ R-134a - LT (-10°F/120°F) 927 3.24 AFF10C1E-IAZ 889 4.06 -3.9% 25.3%AFE13C3E-IAA R-404A - LT (-10°F/120°F) 1450 2.83 AFE14C5E-CAA 1410 3.63 -2.8% 28.3%AFE13C3E-IAV R-404A - LT (-10°F/120°F) 1425 2.93 AFE14C5E-IAV 1400 3.41 -1.8% 16.4%AFE13C3E-IAZ R-404A - LT (-10°F/120°F) 1170 2.8 AFE14C5E-IAZ 1160 3.41 -0.3% 21.8%ARE25C3E-IAA R-134a - HT (45°F/130°F) 2370 6.41 ARE25C4E-CAA 2540 7.04 7.2% 9.8%ARE25C3E-IAZ R-134a - HT (45°F/130°F) 2080 6.2 ARE25C4E-IAZ 2117 7.04 1.8% 13.5%ARE27C3E-IAA R-134a - HT (45°F/130°F) 2760 6.39 ARE25C5E-CAA 2690 8.13 -2.5% 27.2%ARE27C3E-IAZ R-134a - HT (45°F/130°F) 2270 6.1 ARE29C4E-IAZ 2433 6.79 7.2% 11.3%ARE37C3E-IAA R-134a - HT (45°F/130°F) 3730 6.07 ARE35C5E-CAA 3640 7.4 -2.4% 21.9%ARE37C3E-IAV R-134a - HT (45°F/130°F) 3790 6.38 ARE35C5E-IAV 3590 6.96 -5.3% 9.1%ARE37C3E-IAZ R-134a - HT (45°F/130°F) 3170 6.16 ARE35C5E-IAZ 2990 6.96 -5.7% 13.1%ARE41C3E-IAA R-134a - HT (45°F/130°F) 4250 6.2 ARE42C5E-CAA 4440 7.2 4.5% 16.1%ARE41C3E-IAZ R-134a - HT (45°F/130°F) 3680 6.63 ARE42C5E-CAZ 3700 7.2 0.5% 8.6%ARE41C3E-IAV R-134a - HT (45°F/130°F) 4140 6.06 ARE42C5E-IAV 4173 6.67 0.8% 9.9%ASE19C3E-IAA R-404A - MT (20°F/120°F) 1890 4.38 ASE20C4E-CAA 2080 4.58 10.1% 4.5%ASE19C3E-IAZ R-404A - MT (20°F/120°F) 1590 3.7 ASE20C4E-IAZ 1760 4.45 10.7% 20.3%ASE24C3E-IAA R-404A - MT (20°F/120°F) 2290 4.11 ASE24C5E-CAA 2300 4.97 0.4% 20.9%ASE24C3E-IAV R-404A - MT (20°F/120°F) 2400 4.32 ASE24C5E-IAV 2280 4.72 -5.0% 9.3%ASE24C3E-IAZ R-404A - MT (20°F/120°F) 1940 4.2 ASE24C5E-IAZ 1900 4.71 -2.1% 12.1%ASE32C3E-CAA R-404A - MT (20°F/120°F) 3330 4.49 ASE32C5E-CAA 3328 5.32 -0.1% 18.5%ASE32C3E-CAV R-404A - MT (20°F/120°F) 3320 4.54 ASE32C5E-CAV 3328 5.32 0.2% 17.2%ASE32C3E-CAZ R-404A - MT (20°F/120°F) 2760 4.78 ASE32C5E-CAZ 2773 5.32 0.5% 11.3%
Crosses for alternate refrigerants and also for other A*E models are available. Please contact your sales manager for those.
Presentation name (update in Slide Master) 37
Low Temp AFE R404A Envelope
-34 -29 -23 -18 -12 -7
16
21
27
32
38
43
49
54
60
66
60
70
80
90
100
110
120
130
140
150
-30 -25 -20 -15 -10 -5 0 5 10 15 20
Evaporating Temp, °C
Cond
ensi
ng Te
mp,
°C
Cond
ensi
ng Te
mp,
°F
Evaporating Temp, °F
Presentation name (update in Slide Master) 38
Low Temp AFE R134a Envelope
-34 -32 -29 -26 -23 -21 -18 -15 -12 -9 -7
16
21
27
32
38
43
49
54
60
66
60
70
80
90
100
110
120
130
140
150
-30 -25 -20 -15 -10 -5 0 5 10 15 20 25
Evaporating Temp, °C
Cond
ensi
ng Te
mp,
°C
Cond
ensi
ng Te
mp,
°F
Evaporating Temp, °F
Presentation name (update in Slide Master) 39
Ext. Medium Temp AFF R134a Envelope
-34 -29 -23 -18 -12 -7 -1
16
21
27
32
38
43
49
54
60
60
70
80
90
100
110
120
130
140
150
-30 -20 -10 0 10 20 30
Evaporating Temp, °C
Cond
ensi
ng Te
mp,
°C
Cond
ensi
ng Te
mp,
°F
Evaporating Temp, °F
Presentation name (update in Slide Master) 40
Medium Temp ASE R404A Envelope
-29 -23 -18 -12 -7 -1 4
16
21
27
32
38
43
49
54
60
66
60
70
80
90
100
110
120
130
140
150
-20 -10 0 10 20 30 40
Evaporating Temp, °C
Cond
ensi
ng Te
mp,
°C
Cond
ensi
ng Te
mp,
°F
Evaporating Temp, °F
Presentation name (update in Slide Master) 41
High Temp ARE R134a Envelople
-23 -18 -12 -7 -1 4 10 16
16
21
27
32
38
43
49
54
60
66
60
70
80
90
100
110
120
130
140
150
-10 0 10 20 30 40 50 60
Evaporating Temp, °C
Cond
ensi
ng Te
mp,
°C
Cond
ensi
ng Te
mp,
°F
Evaporating Temp, °F
Presentation name (update in Slide Master) 42
Representataive DrawingsC3E/C4E vs C5E
C3E/C4E Drawing No. 497-2844-00 C5E Drawing No. 497-1937-00
Presentation name (update in Slide Master) 43
Representataive DrawingsC3E/C4E vs AFF
C3E/C4E Drawing No. 497-2844-00 AFF Drawing No. 497-1955-00
Presentation name (update in Slide Master) 4444Presentation name (update in Slide Master)
Rating Data in CPID and OPI
All performance data sheets are available on CPID and OPIWill be available for models under development per release schedule
Presentation name (update in Slide Master) 4545Presentation name (update in Slide Master)
Rating Data in CPID and OPI
All performance data sheets are available on CPID and OPI Will be abailable for models under development per release schedule
Presentation name (update in Slide Master) 46
UL InformationFile SA4369,
Vol. 1, Sec. 34
Reference Drawings
Accessories List
Application Engineering Bulletin
AE-1305
Performance Information & Coefficients Electrical
Information
Additional Resources Available by Registering for Online Product Information at www.EmersonClimate.com
Presentation name (update in Slide Master) 47
Hermetic Compressor Nomenclature