Upload
vokhuong
View
216
Download
0
Embed Size (px)
Citation preview
Copper Shielded Battery CableHigh Performance
Flexible
Prestolite Wire Brand copper shielded battery cables are designed to meet the needs of today's vehicle requirements for hybrid, plug-in hybrid, and electric propulsion systems, as well as numerous other AC and DC applications. These cables are available in a variety of performance categories in thin and thick wall constructions for the most demanding operating temperature environments from 125°C to 225°C, and voltages up to 1500V.
Prestolite Wire has been a market leader in the engineering development and manufacturing of high performance wire and cable since 1911, serving the needs of global transportation and industrial customers.
Applications• High Voltage Propulsion Systems
• Battery Pack Interconnect
• Inverter to Electric Motor
• Electric Power Steering
• Electric Braking
• Electric Air Conditioning
Features• Insulation Choices including EPDM and XLFE
• Copper Conductors
• Operating Temperature: 125°C, 150°C, 200°C, 225°C
• Excellent Fluid, Abrasion, and Cut-thru Resistance
• Safety of Cross-Linked Products
• RoHS Compliant
Compliance• Meets and exceeds the following requirements:
• ISO 6722
• ISO 19642 (2018)
• GMW15839
Thin -wall Constructions*
Nominal Conductor
Size (mm2)
Maximum Conductor Diameter
(mm)
Core Cable OD
(mm)
Maximum Braided
Core Diameter
(mm)
Nominal Jacket
Thickness (mm)
Finished Cable OD
(mm) min max min max
3 2.4 3.1 3.4 4.0 0.4 4.2 4.8 4 2.8 3.4 3.7 4.3 0.4 4.5 5.1 5 3.1 3.9 4.2 4.8 0.6 5.4 6.0 6 3.4 4.0 4.3 4.9 0.6 5.5 6.1 8 4.3 4.6 5.0 5.8 0.65 6.5 7.1
10 4.5 5.3 6.0 6.8 0.65 7.5 8.1 12 5.4 5.8 6.5 7.3 0.65 8.0 8.6 16 6.3 6.4 7.2 8.0 0.8 9.0 9.6 20 6.9 7.0 7.8 8.6 0.8 9.6 10.2 25 7.8 7.9 8.7 9.5 0.9 10.7 11.3 30 8.3 8.7 9.6 10.4 0.9 11.6 12.2 35 9.0 9.4 10.4 11.2 1.0 12.6 13.2 40 9.6 10.0 11.1 11.9 1.0 13.3 13.9 50 10.5 11.0 12.2 13.0 1.1 14.6 15.2 60 11.6 12.0 13.3 14.1 1.1 15.5 16.3 70 12.5 13.0 14.4 15.2 1.1 16.6 17.4
Thick -wall Constructions*
Nominal Conductor
Size (mm2)
Maximum Conductor Diameter
(mm)
Core Cable OD
(mm)
Maximum Braided
Core Diameter
(mm)
Nominal Jacket
Thickness (mm)
Finished Cable OD
(mm) min max min max
3 2.4 3.8 4.1 4.7 1.0 6.1 6.7 4 2.8 4.0 4.4 5.0 1.1 6.6 7.2 5 3.1 4.5 4.9 5.5 1.1 7.1 7.7 6 3.4 4.6 5.0 5.6 1.1 7.2 7.8 8 4.3 5.0 5.9 6.7 1.2 8.5 9.1
10 4.5 5.9 6.5 7.3 1.2 9.1 9.7 12 5.4 6.6 7.4 8.2 1.3 10.2 10.8 16 6.3 7.7 8.3 9.1 1.3 11.1 11.7 20 6.9 8.1 9.1 9.9 1.4 12.1 12.7 25 7.8 9.4 10.4 11.2 1.4 13.4 14.0 30 8.3 9.7 10.9 11.7 1.5 14.1 14.7 35 9.0 9.6 11.6 12.4 1.5 14.8 15.4 40 9.6 11.2 12.4 13.2 1.5 15.6 16.2 50 10.5 11.5 13.5 14.3 1.6 16.7 17.5 60 11.6 13.4 14.6 15.4 1.6 17.8 18.6 70 12.5 13.5 15.5 16.5 1.6 18.9 19.7
* Conductor stranding available per customer application requirements