Copy of omputer Networking System for NCCOM 301111.xls

  • Upload
    my09

  • View
    224

  • Download
    0

Embed Size (px)

Citation preview

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    1/19

    Sl.

    No.

    Description of Items Qty Unit Rate Amount

    1 Providing following capacity 2800 - 2900 RPM single stage Centrifugalwater pump manufactured according to DIN/VDE/ISO 9001 standard

    complete with steel base plate frame, coupling flange with gaskets, bolts,

    nuts & standard, accessories etc. or closed coupled as required coupled

    with 3-phase, 400 volt 5 %, 50 Hz 2900 RPM Horizontal motor having

    six terminals for star-delta or DOL starting & totally enclosed fan cooled

    & in built thermal protection etc. Made by CROMPTON

    GREAVES/GEC / Pedrollo/SIEMENS/ or equivalent approved by theEngineeing-in-Charge.

    5 H.P Tria bloc Pump Motor Set (KSB or equivalent approved by the

    Engineeing-in-Charge.

    Suction and delivery: 50 mm x 32 mm ( 2 " x 1.25" )

    Discharge capacity :(5 -3 4) m/hr

    Head: 40-22 meter 2 Set 118462 236924

    2

    Providing & fixing cast iron reflux vales(Non-Return valve) with cast iron

    body, reflux valve cover plate, flap, valve disc & flap lined with leather,

    cast iron hanging arm, stainless steel louver shaft & bolt with covergasket etc. including all other standard accessories (manufactured

    according toDIN / ISO standard) as per sample approved by the

    Engineer-in-charge. (MPL or equivalent approved by the Engineeing-in-

    Charge.)Dia 50 mm (2) 1 No 3672 3672

    3

    Installation, Testing and Commissioning of the following capacity

    Centrifugal water pump-motor Set on 304.8 mm (1') high (152.4 mm

    below and 152.4 mm above floor level) C.C (1:2:4 ) base of required size

    with 12.7 mm (") thick (1:4) cement plastering and neat cement finishing

    over the exposed C.C surface, providing and fixing necessary bolts, nuts,

    vibration isolator with making all electrical and pipe connection asrequired as per direction of the Engineer in charge.

    Up to 7.5 HP. 2 Set 5265 10530

    KvRi bvg: - b`wbs Ae evsjv`k wcRbm wWcvUgU _vcwKDigU Ae gWvb BKzBcgU UvcvU , KbvKkb AewijUW vKPvi cKi AvIZvq Kviv Awa`ii K`xq wWcvi,

    Rjvi WcywU Rjvi WigUix I Kviv cwievi KjvY ms vi feb cvwb

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    2/19

    4

    Supply and installation of metal clad surface mounting type three phase

    400 5% Volt 50 Hz. automatic direct-on -line (DOL) motor starter

    complete with contractor, overload relay coil, etc. (Foreign made) of the

    following range of rated current including supply of required fixing

    materials as per direction of the Engineer in charge. (assembled by /

    ADEX/SIEMENS/ SIGMA PUMP LTD or equivalent approved by the

    Engineeing-in-Charge.)4 Amps to 17Amps (up to 5 H.P.) 2 Nos 7297 14594

    5

    Supplying, fitting and fixing G.I. pipe with all special fittings, such as bends,

    elbows, sockets, reducing sockets, Tee, unions, jam-nuts etc. including cutting

    trenches where necessary and fitting the same with earth duly rammed and

    fixing in walls with holder bats and making hole in floors, walls and consequent

    mending good the damages etc. all complete in all respects approved and

    accepted by the Engineer.

    50 mm dia G.I. Pipe with wall thickness 4.50 mm, outside diameter min

    59.8 mm, weight 6.17 kg/m, can withstand min 50 kg/cm2 hydraulicpressure. 20 Mtrs 840 16800

    32 mm dia G.I. Pipe with wall thickness 4.05 mm, outside diameter min

    42.1 mm, weight 3.84 kg/m, can withstand min 50 kg/cm2

    hydraulic

    pressure. 5 Mtrs 513 2565

    6

    Supplying, fitting and fixing best quality G.I. gate valve with sealant etc.

    complete approved and accepted by the Engineer.

    32 mm brass gate valve 2 Nos 584 1168

    7

    Supplying, fitting and fixing best quality G.I. Check valve, threaded jointwith sealant etc. complete approved and accepted by the Engineer.

    50 mm brass check valve 2 Nos 1331 2662

    8

    Providing & laying of the following PVC insulated & sheathed cable of

    (NYY) with PVC insulated green/white coloured ECC wire (BYA

    connecting at both ends, through PVC pipe & accessories in the following

    manner:

    In kutcha ground by cutting 45.70 cm width x 91.40 cm depth trench with

    necessary brick or tile protection and mending the damages good by

    refilling trench with proper compaction;

    In pucca floor through PVC pipe by cutting trench of necessary size andmending the damages good by brick soling, 75 mm (1:2:4) CC work with

    neat cement finishing etc.Cables manufactured by BRB/Paradise/Poly/ Supersign or equivalent

    approved by the Engineering-in-Charge

    1C-4 x 6 sq.mm (NYY) with 6 sq.mm (BYA) ECC wire through PVC pipe

    of minimum inner dia 40 mm having wall thickness of 1.9 mm

    In kutcha ground 65 626 40690

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    3/19

    In pucca floor 12 708 8496

    9 Providing & fixing on a prepared board 500 volt grade following Triple-pole moulded case Circuit Breaker (TPMCCB) with thermal over-current

    and instantaneous electromagnetic short circuit release provision.Brand

    and Country of origin of TPMCCB areABB (Italy), AEG (Germany),

    DORMAN SMITH (England), LEGRAND (France/Italy), MEM (UK),

    MERLIN GERIN (France), or equivalent approved by the Engineering-in-

    Charge.32/40 Amps. (Minimum 10-KA) 3 Nos 7925 23775

    10 Providing and fixing of pedestal type 18 SWG M.S. sheet steel board withproper reinforcement by M.S. flat bars, duly painted with two coats of

    enamel paint over prime anticorrosive red oxide coat fitted on wall/floor

    with necessary angle iron clamps/legs as per direction of the Engineer-in

    charge. 1 Sq.M 3879 3879Total Taka 365755

    Md. Karim uddin Shekar Chandra Biswas

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    4/19

    Sl.

    No.

    Description of Items Qty Unit Rate Amount

    1 Media Converter

    Sub Head -A (Network Backbone Part)

    Construction of National Crime Control & OperationMonitoring(NCCOM) Center

    at Police Head Quarter Complex, Phulbaria, Dhaka. (Sub Head: Supply,

    Installation, Testing & Commissioning of Computer Networking & Internet

    System)

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    5/19

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    6/19

    SWITCH (Core Switch)

    Supply, Installation, Testing & Commissioning of Gigabit manageable

    backbone/Core Switch with minimum 12-1000 Base-SX Port (Fiber)

    and 12-1000Base-T Gigabit Ethernet Port with following Specification &

    features as per direction of the Engineer -in -charge

    Brand: CISCO or any internationally reputed brand

    Model: (to be mentioned by Contractor)

    Country of Origin: USA/UK/Japan/Korea or equivalent

    Chassis Features:

    Total Number of Slots : 3 (three)

    Line Card Slots : 2 (two)

    Engine Slots : 1 (one)

    Number of Fan-Tray Bays : 1 (one)

    Should have Redundant Power Supply

    Line Card specification:

    Minimum 6-Port 10/100/1000 PoE or SFP (Optional)

    6 (six) 1000BASE-SX SFP module should be installed

    Engine Performance and Switching Specifications :

    Should have 12 10/100/1000 PoE and 8 SFP Ports on Engine

    6 (six) 1000BASE-SX SFP module should be installed with the Engine

    64-GBps switch fabric

    48-mpps Layer 2 forwarding (hardware)

    Layers 2 through 4 hardware-based switch

    engine (application-specific integrated circuit [ASIC] based)

    Centralized design

    Unicast and multicast routing entries : 32,000

    Layer 2 multicast addresses : 16,384

    MAC addresses : 32,768

    VLANs : 2048 active VLANs

    Per-VLAN Spanning Tree (PVST+) and Per-VLAN Rapid Spanning

    Tree Protocol (PVRST)

    CPU (MHz) : 266 MHz

    IP Forwarding Information Base (FIB) Entries : 32,000

    Quality-of-Service (QoS) Sharing: Gigabit Ethernet only

    Synchronous Dynamic RAM (SDRAM) : 256 MB

    Onboard Flash Memory : 32 MB

    Active Virtual LANs (VLANs) : 2000

    Multicast Entries : 8000

    Hardware-based routing at : 48mpps

    Type of buffers : Dynamic

    Spanning Tree Protocol Instances : 1500

    Switched Virtual Interfaces (SVIs) : 1000

    Internet Group Management

    Protocol (IGMP) Snooping : Yes (16,000)

    Security/QoS Hardware Entries : 32,000

    Policers : 512 egress; 512

    Jumbo Frames : up to 9216 bytes

    Baby Giants : up to 1600 bytes

    Engine should support below Layer 2 (two)Features:

    2

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    7/19

    Inter-Switch Link (ISL) VLAN encapsulation, Support for 2048 active

    VLANs and 4096 VLAN IDs per switch, Ether Channel technology,

    Fast Ether Channel, and Gigabit Ether Channel technology across line

    cards, Port Aggregation Protocol,

    Unidirectional link detection (UDLD) and aggressive UDLD, Q-in-Q

    passthrough, Forced 10/100 auto negotiation, Web Content

    Communication Protocol Version 2 Layer 2 Redirect, Private VLAN

    (PVLAN) Promiscuous Trunk, Match class of service (CoS) for non-

    IPv4 traffic, L2TP, CoS mutation.

    Engine should support below layer 3 (three) features:

    IGMP filtering on access and trunk ports, IP multicast routing protocols

    (Protocol Independent Multicast [PIM], Source Specific Multicast

    [SSM], Distance Vector Multicast Routing Protocol [DVMRP]), Group

    Multicast Protocol server, Full Internet Control Message Protocol

    (ICMP) support

    ICMP Router Discovery Protocol, IPv6 software switches, EIGRP stub,

    Virtual Router Redundancy Protocol (VRRP)

    QoS and Traffic Management features:

    Per-port QoS configuration, Support for four queues per port in

    hardware, Strict priority queuing, IP differentiated service code point(DSCP) and IP Precedence, Classification and marking based on IP

    type of service (ToS) or DSCP, Classification and marking based on full

    Layer 3 and Layer 4 headers (IP only), Input and output policing based

    on Layer 3 and Layer 4 headers (IP only), Support for 512 policers on

    ingress and 512 policers on egress configured as aggregate or

    individual, Shaping and sharing output queue management, Dynamic

    Buffer Limiting (DBL): congestion-avoidance feature, No performance

    penalty for granular QoS functions, Auto-QoS CLI for voice-over-IP

    (VoIP) deployment, Per-port, per-VLAN QoS, Selective DBL

    Predictable Performance

    Layer 4 TCP/UDP hardware-based filtering at 48mpps

    No performance penalty with advanced Layer 3 and Layer 4 services

    enabled

    Software-based learning at a sustained rate of 500 hosts per second

    Support for 32,000 MAC addresses

    Support for 32,000 entries in routing table, shared between unicast &

    multicast

    Bandwidth aggregation up to 16 Gbps through Gigabit Ether Channel

    technoHardware-based multicast management

    Hardware-based ACLs, router ACLs (RACLs) and VLAN ACLs

    (VACLs)

    Comprehensive Management features:

    Manageable through Network Assistant

    Single console port and single IP address to manage all system features

    Software configuration management, including local and remote

    storage

    Simple Network Management Protocol (SNMP) Versions 1, 2, and 3

    instrumentation, delivering comprehensive in-band management

    CLI-based management console to provide detailed out-of-band

    management

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    8/19

    Remote Monitoring (RMON) software agent to support four RMON

    groups (history, statistics, alarms, and events) for enhanced traffic

    management, monitoring, and analysis

    Support for all nine RMON groups through the use of a Switch Probe

    analyzer (Switched Port Analyzer [SPAN]) port, which permits traffic

    monitoring of a single port, a group of ports, or the entire switch from a

    single network analyzer or RMON probe

    Analysis support, including ingress port, egress port, and VLAN SPANLayer 2 traceroute, Remote SPAN (RSPAN), Smartports macros, SPAN

    ACL filtering, SPAN CPU port, Dynamic Host Configuration Protocol

    (DHCP) client auto configuration, Enhanced SNMP MIB support, Time

    Domain Reflectometry (TDR), MAC Address Notification, Generic

    Online Diagnostics (GOLD)

    Advanced Network Security features:

    TACACS+ and RADIUS, which help enable centralized control of the

    switch and restrict unauthorized users from altering the configuration,

    Standard and extended ACLs on all ports, 802.1x user authentication

    (with VLAN assignment, voice VLAN, port security, guest VLAN,

    private guest VLAN, PVLAN, and RADIUS-supplied session timeout

    extensions), 802.1x accounting, 802.1x authentication failure, 802.1x

    PVLAN assignment, 802.1x Private Guest VLAN, 802.1x RADIUS-

    supplied time out, NAC Layer 2 802.1x, NAC Layer 2 IP, Trusted

    boundary, RACLs on all ports (no performance penalty), VACLs, Port

    ACLs (PACLs), PVLANs on access and trunk ports, DHCP snooping,

    DHCP Option 82, DHCP Option 82 insertion, DHCP Option 82 Pass

    Through, Port security, Sticky port security, Secure Shell (SSH) Protocol

    Versions 1 and 2, VLAN , Management Policy Server (VMPS) client,

    Unicast MAC filtering, Unicast port flood blocking, Dynamic Address

    Resolution Protocol (ARP) inspection, IP Source Guard, Community

    PVLANs, Trunk Port Security, 802.1x Inaccessible Authentication

    Bypass, MAC Authentication Bypass Control Plane Policing, 802.1x

    Unidirectional Controlled Port,

    Voice VLAN Sticky Port Security Secure Copy Protocol (SCP), EtherChannel Trunk Port Security, IP Source Guard for Static Hosts, IEEE

    802.1x Multi domain Authentication

    High Availability features:

    HSRP, VRRP

    Regulatory Compliance: CE marking

    Safety:

    UL 60950, CAN/CSA-C22.2 No. 60950, EN 60950, IEC 60950, TS 001,

    AS/NZS 3260

    EMC: FCC Part 15 (CFR 47) Class A, ICES-003 Class A, CISPR22 Class

    A, AS/NZS 3548 Class A, VCCI Class A, EN 55022, EN 55024, EN

    61000-6-1, EN 50082-1, EN 61000-3-2, EN 61000-3-3, ETS 300 386

    Warranty:

    The Contractor shall provide warranty of the system for 1 (one) year

    from the date of successful Commissioning ( manufacturer warranty

    part number must be mentioned)1

    No.(M/R)

    1007802 1007802

    SERVER

    Supply, Installation, Testing & Commissioning of Server with following

    Specification or equivalent as per direction of the Engineer-in-charge.

    Brand: HP/ Dell/ IBM or any internationally reputed brand

    Country of Origin: USA/UK/Japan/Korea or equivalent

    3

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    9/19

    Specification:

    Processor : Quad-Core Intel XeonTM

    Clock speed : 2.53 GHz

    Chipset : Intel 5520 series or higher

    QPI : 5.86 GT/s Quick Path Interconnect

    No. of Processor : 1 (one), up-gradable up to 2 (two)

    Cache Memory : Min. 8 MB L3 cache

    Memory : Min. 8 GB (2x4GB or 4x2GB) DDR3

    installed Upgradeable up to 144 GB (Min.18 DIMM Slots)

    Hard Drive : Min. 4 (four) x 146 GB Hot Plug SAS (15K rpm)

    Optical Drive : DVD +/- RW (factory fitted)

    Storage type : Hot Plug 2.5-inch. SAS/ SATA

    Drive bays : Min. 8, Hot Plug to support SAS & SATA drives

    Expansion Slots : 3 (three) PCI Express

    RAID Controller : RAID controller with 256 MB Battery backed

    cache (supporting RAID level- 0,1,5,6 SAS/SATA)

    Graphics : Integrated Video Controller with 16 MB Video

    Memory

    I/O Ports : Min. 4-USB 2.0 (2 up front), Serial, Video (15-pin),VGA, Keyboard

    OS Support : Microsoft Windows 2003/2008 Server, Novell

    Netware, LINUX (RedHat, SUSE)

    System Management: System management software to be provided

    with the server (should have the capacity to manage all servers from a

    single console)

    Security : Power-on password, Setup password, Diskette

    boot control, Parallel and serial interface control, Disk

    configuration lock, Power switch security

    Power Supply : 230V AC Input Voltage, hot-plug, redundant

    power w/ redundant hot plug cooling fanForm Factor : Rack-mount chassis with mounting kits

    Warranty : 03(three) Years fully on-site from the date of

    successful commissioning

    Benchmarking : Performance test report must be attached by the

    Contractor (of specific organisation or equivalent size & capacity of

    Server). Mail/Database/Web/APP/DNS Server1

    No.(M/R)

    343128 343128

    ROUTER

    Supply, Installation, Testing & Commissioning of Modulator Router

    with following Specification or equivalent features as per direction of

    the Engineer- in- charge.

    Brand: CISCO or any internationally reputed brand

    System Features:

    Should have Embedded hardware-based cryptography acceleration

    (IPSec + SSL)

    Total onboard WAN 10/100/1000 Ports: 03 (RJ-45-based)

    Should have 2-Port Serial WAN Interface Card with V.35 compatible

    cable

    Service Module slots: 01

    EHWIC slots: 04

    Double-wide EHWIC slots: 02

    ISM slots: 01

    4

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    10/19

    Onboard DSP (PVDM) slots: 02

    Memory DDR2 ECC DRAM Default: 512 MB

    Memory (DDR2 ECC DRAM) Maximum: 2 GB

    Compact Flash (ext.) Default: Slot 0: 256 MB, Slot 1: none

    Compact Flash (ext.) Maximum: Slot 0: 4 GB, Slot 1: 4 GB

    Serial console port and Serial auxiliary port: 01

    Router Switching Performance: 353,000 PPS & 180.73 Mbps

    SIP Sessions: 200

    IOS Should Support BGP, OSPF, EIGRP, IS-IS, RIP, PBR, IGMP, IOS

    Firewall, SSL VPN, DMVPN, IPS, GET VPN, IP Sec.

    Multicast forwarding, Protocol independent Multicast (PIM) (both

    sparse and dense mode), (S,G), (*,G), Bidirectional PIM in hardware

    Comprehensive MPLS supported

    Group Management Protocol and Internet Group Management

    Protocol (IGMP) snooping

    Layer 3 routing protocols, Border Gateway Protocol version 4 (BGPv4),

    Open Shortest Path First (OSPF), Intermediate System-to-Intermediate

    System (IS-IS), Routing Information Protocol (RIP), Distributed FIB

    Switching, Internet Control Message Protocol (ICMP)

    Should provide advanced security services and management

    capabilities such as built-in hardware encryption acceleration, IP

    Security (IPSec), VPN (Advanced Encryption Standard [AES], Triple

    Digital Encryption Standard [3DES], DES

    IOS Firewall zoning

    High speed WAN environments with concurrent services enabled up

    to 75 Mbps multi-gigabit fabric enabled high-bandwidth module-to-

    module communication without compromising routing performance

    Energy-saving features

    Powered by high-performance multi-core processors

    Embedded hardware encryption acceleration

    TDM interconnectivity fabric in the system architecture Supporteduniversal-serial-bus (USB)-based console access

    Up-gradation option to internal power supply for 802.3af-compliant

    PoE integrated switch modules

    Single OS image encompassing all IOS technology features

    Standards-certified Voice XML browser services

    IPT (Supported):Future up-gradation possibility for IPphonecall

    processing,Future up-gradation possibilityforbackup/fallbackIP

    phonecallprocessing,up-gradationpossibility for voice

    messagingand auto attendant, scalability for centralized and

    distributed call processing

    Protocol should support backup routes and unequal cost load

    balancingSupport for Unified Wireless Architecture

    Support for Third-generation (3G) wireless WAN modules

    Environmental Specifications:

    (i) Operating Conditions : Temperature: 32F to 104F (0C to

    40C) Maximum altitude: 5,906 feet (1,800m), Altitude: 13,000 ft

    (4,000m), Relative humidity: 5% to 85%;

    (ii) Non-operating Conditions : Temperature: 40F to 176F (40C to

    80C), Altitude: 15,000 ft (4,570m), Relative humidity: 5% to 95%

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    11/19

    Safety Compliance: UL 60950-1, CAN/CSA C22.2 No. 60950-1, EN

    60950-1, AS/NZS 60950-1, IEC 60950-1

    Electromagnetic Compatibility (EMC): 47 CFR, Part 15, ICES-003

    Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A,

    VCCI V-3, CNS 13438, EN 300-386, EN 61000 (Immunity), EN 55024,

    CISPR 24, EN50082-1

    Power Specifications:

    AC input voltage : 100 to 240 VAC auto rangingAC input frequency : 47 to 63 Hz

    AC input current range AC power supply (max): 2.2 to 1.0A

    AC input surge current :

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    12/19

    7 DMZ Switch (Managable Switch)

    8 Fiber Optic Cable

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    13/19

    Total Taka 2999251

    Md. Ayub Ali Shekhar Chandra Biswas

    Sub-Assistant Engineer Sub-Divisional Engineer

    PWD E/M Sub Division-8 PWD E/M Sub Division-8

    Motijheel, Dhaka. Motijheel, Dhaka.

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    14/19

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    15/19

    WIRELESS ACCESS POINT (WAP)3

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    16/19

    Supply, Installation, Testing & Commissioning of wire less Access Point

    with following Specification & features as per direction of the Engineer

    in- charge.

    Brand : CISCO or any internationally reputed brand

    (to be mentioned by Contractor)

    Model : (to be mentioned by Contractor)Country of Origin : USA/UK/Japan/Korea/ or Equivalent

    Standalone 802.11a/g/n Wireless LAN Access Point supporting dual

    frequency band, MAC filtering, web-based configuration, centralized

    security management and having minimum 200m indoor coverage with

    following features:

    2x3 multiple-input multiple-output (MIMO) with 2 (two) spatial

    Maximal ratio combining (MRC)

    Legacy beam forming

    20- and 40-MHz channels

    PHY data rates up to 300 Mbps

    Packet aggregation: A-MPDU (Tx/Rx), A-MSDU (Tx/Rx)

    802.11 dynamic frequency selection (DFS) (Bin 5)

    Cyclic shift diversity (CSD) support

    Should have features like Radio resource management (RRM), Clean

    Air technology etc.

    Data Rates Supported:

    802.11a: 6, 9, 12, 18,24, 36, 48, and 54 Mbps

    802.11g: 1, 2, 5.5, 6,9, 11, 12, 18, 24, 36, 48, and 54 Mbps

    Integrated Antenna:

    2.4 GHz, Gain 4.0 dBi, horizontal beam width 360

    5 GHz, Gain 3 dBi, horizontal beam width 360Interfaces:

    10/100/1000BASE-Tautosensing (RJ-45)

    Management console port (RJ45)

    Environmental:

    Non-operating (storage) temp : -22F to 185F (-30C to 85C)

    Operating temperature : 32F to 104F (0C to 40C)

    Operating humidity : 10% to 90% (non-condensing)

    System Memory:

    128 MB DRAM

    32 MB flashSafety Standards:

    UL 60950-1, CAN/CSA-C22.2 No 60950-1, UL 2043, IEC 60950-1, EN

    60950-1

    Security:

    802.11i, Wi-Fi Protected Access 2 (WPA2), WPA

    802.1 X

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    17/19

    Advanced Encryption Standards (AES), Temporal Key Integrity

    Protocol (TKIP)

    Warranty:

    The Contractor shall provide warranty of the system for 1 (one) year

    from the date of successful Commissioning ( manufacturer warranty

    part number must be mentioned)QTY = {GF-1, (FF- 4F)@ 3 Nos.( 5F-2Nos. & 6F- 1 No.}

    16Nos.

    (M/R)

    47238 755

    MDF / Network Rack with Patch Panel

    Supply, Installation, Testing & Commissioning of MDF / Network Rack

    with Patch Panel with following Specification as per direction of the

    Engineer in charge.Brand : Any internationally reputed brand, (to be mentioned by bidder)

    Specification:

    Industry-made brand MDF (Main Distribution Facility) with Fiber

    Patch Panel (24 Port Rack Mount loaded with SC Adapters) and GE

    Patch Panel of appropriate type & size (accommodating switches,

    routers, server farm/ DMZ switches, patch cord of appropriate type &size etc) including wire manager, necessary cable ties etc complete with

    all required accessories and following features:

    Rack Size : 42U

    Cooling System : Min. 4 AC Cooling Fans

    Front Door : Perforated Glass Removable Door with

    Rear Door : 1 (one)

    Ventilation : Superior Ventilation

    Cable Run System : Separate Runways for Top & Bottom cable

    runsVertical Cable Organizer : Yes, Min.8 Cable Rings

    PDU/ Power Strip : Min.4 (four) Nos. Power Strip having Min.

    6 (six) Outlets each (16 Amp.)

    Power Distribution : Sub-distribution Board incl. Ground Bar

    Post : Min.4 Nos. of Heavy Duty Feet/Wheels1

    No.(M/R)

    292287 292

    Wiring with UTP Cat-6 Cable

    Surface channel wiring with UTP Cat-6 Cable through 1mm thick PVC

    channel complete with other accessories etc. as required including

    mending the damages good as per sample approved by the Engineer-in

    charge.

    1000Mtrs

    (M/R)114 114

    UPS

    Supply, Testing & Commissioning of 1000 VA uninterruptible power

    supply (UPS) complete with central processing unit suitable for input

    supply 160-275 volt AC single phase 50 Hz for output voltage 220 volt

    5%, 50 Hz single phase having protection for lightening & surge, back-

    Back-up time: 30 minutes at full load & 60 minutes at half load

    (One for Core Switch & another for Server) 2Nos.(S/R)

    20323 40

    6

    4

    5

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    18/19

    7 UPS

    FACE PLATE(Cat-6 UTP )

    Supply, Installation, Testing & Commissioning of FACE PLATE (Cat-6

    UTP) with following Specification as per direction of the Engineer in

    charge.

    Specification:

    Face Plate with MK Box (plastic type), dual module with cover and all

    required accessories. (For Wireless Access Points)25

    Nos.

    (M/R)

    650 16

    PATCH CORD (Cat-6 UTP)Supply, Installation of PATCH CORD (Cat-6 UTP) with following

    Specification as per direction of the Engineer- in- charge.

    Brand: Digi-Link/ AMP/ Micronet/ Systimax/ Belkin or equivalent

    Specification:

    Industry-made brand 3 (three) meters Patch Cord of Cat-6 UTP cable

    with RJ-45 connectors at both ends and all required accessories25

    Nos.(M/R)

    359 8

    PATCH CORD (Multimiode FO)Supply, Installation of PATCH CORD (Cat-6 UTP) with following

    Specification as per direction of the Engineer- in- charge.

    Brand: Digi-Link/ AMP/ Micronet/ Systimax/ Belkin or equivalent

    Specification:

    Industry-made brand 3 (three) meters Patch Cord of Cat-6 UTP cable

    with RJ-45 connectors at both ends and all required accessories

    25 Nos.(M/R)

    359 8

    11 Fiber Optic SC Connector

    12 Patch Panel(Fiber)

    10

    8

    9

  • 7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls

    19/19

    13 Wireless Adaptor

    14 Power Socket

    15 Pwer Wiring

    LAN INSTALLATION

    Installation of LAN including replacement of the existing UTP

    backbone with Fiber Optic backbone etc complete as per the guideline

    provided in the TOR and as per direction& satisfaction of the Engineer-

    in- charge.

    1Job(M/R)

    50000 50

    Total Taka 3008

    Md. Ayub Ali Shekhar Chandra Biswas

    Sub-Assistant Engineer Sub-Divisional Engineer

    PWD E/M Sub Division-8 PWD E/M Sub Division-8

    Motijheel, Dhaka. Motijheel, Dhaka.

    16