COYOTE ® DTC (Drop Termination Closure) Splice Tray Kit For Expressed Buffer Tube Applications – 48 ct. Buffer Tube Cable or Less MARCH 2019 Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 1. DTC Splice Tray (1) 2. DTC Tray Support (1) 3. Single Stack LITE-GRIP ® Splice Blocks (4) © 2019 Preformed Line Products Company. All rights reserved. NOMENCLATURE 1 2 3 4 5 COYOTE DTC (Drop Termination Closure) Kit COYDTC-001 COYOTE DTC Closure Kit for Flat and Small Drop Cables: Cable Diameters of .125" – .25" (3.2 – 6.4 mm) COYDTC-002 COYOTE DTC Closure Kit for Large and Round Cables: Cable Diameters of .25" – .37" (6.4 – 9.4 mm) COYDTC-003 COYOTE DTC Closure Kit for Large Round Shielded Drop Cables: Cable Diameters of .25" – .37" (6.4 – 9.4 mm) Accessory Kits 80809960 Hose Clamp Clip Kit – Includes (4) Small Hose Clamps and (4) Hose Clamp Retention Clips 80811033 Grommet Kit for Cables with Diameters .125" – .25" (3.2 – 6.3 mm) – Includes (4) grommets 80811034 Grommet Kit for Cables with Diameters .25" – .37" (6.3 – 9.4 mm) – Includes (4) grommets 80811237 Splice Tray Kit for DTC COYGLC-C1-000 COYOTE GLC Base with Flat Cover Tools Required • Snips • Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1) 5. Felt Strip (1)

COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

COYOTE® DTC (Drop Termination Closure) Splice Tray Kit For Expressed Buffer Tube Applications – 48 ct. Buffer Tube Cable or Less

MARCH 2019

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED™ product before application.

1. DTC Splice Tray (1) 2. DTC Tray Support (1)

3. Single Stack LITE-GRIP® Splice Blocks (4)

© 2019 Preformed Line Products Company. All rights reserved.

NOMENCLATURE

1 2

3

4

5

COYOTE DTC (Drop Termination Closure) Kit

COYDTC-001 COYOTE DTC Closure Kit for Flat and Small Drop Cables: Cable Diameters of .125" – .25" (3.2 – 6.4 mm)

COYDTC-002 COYOTE DTC Closure Kit for Large and Round Cables: Cable Diameters of .25" – .37" (6.4 – 9.4 mm)

COYDTC-003 COYOTE DTC Closure Kit for Large Round Shielded Drop Cables: Cable Diameters of .25" – .37" (6.4 – 9.4 mm)

Accessory Kits

80809960 Hose Clamp Clip Kit – Includes (4) Small Hose Clamps and (4) Hose Clamp Retention Clips

80811033 Grommet Kit for Cables with Diameters .125" – .25" (3.2 – 6.3 mm) – Includes (4) grommets

80811034 Grommet Kit for Cables with Diameters .25" – .37" (6.3 – 9.4 mm) – Includes (4) grommets

80811237 Splice Tray Kit for DTC

COYGLC-C1-000 COYOTE GLC Base with Flat Cover

Tools Required

• Snips

• Fiber optic cable opening tools

• Flat head screwdriver

4. Bag of Tie Wraps (1) 5. Felt Strip (1)

Page 2: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

2

Step #1 Install tray support into base.

Base Preparation

Tabs without notch insert into slots in base

Slots

Tray support installed in base.

Step #2 Determine cable entry locations for butt applications as shown below.

Butt Applications

Unused Cable Port

Expressed Cable In

Expressed Cable Out

OR

Branch/Drop Cable In

Branch/Drop Cable In

Expressed Cable Out

Expressed Cable In

Unused Cable Port

Page 3: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

3

Step #4 Cut the edges of tab.

Remove the selected tab.

Step #3 Determine cable entry locations for In-Line applications as shown below.

In-Line Applications

Unused Cable Port

Expressed Cable In

Branch/Drop Cable Out

OR

ExpressedCable Out

Expressed Cable Out

Branch/Drop Cable In

Expressed Cable In

Unused Cable Port

Step #5 Measure and remove sheath for mid sheath applications (express/balloon/ring cut) – 48 ct. buffer tube cable or less as shown below.

Expressed Cable Preparation

IMPORTANT NOTE: A maximum of 3 buffer tubes can be expressed in the COYOTE® DTC with Splice Tray.

Butt Applications = 42" (1.1 m)In-Line Applications = 50" (1.3 m)

OFFICE/C.O.

Page 4: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

4

1.5" (38 mm)

Step #6 Trim the strength member of the cable.

Head of hose clamp must be positioned on top of cable.

Step #7 Secure the cable to the hose clamp retention clip with the hose clamp as shown below.

Align retention clip with cable sheath opening.Grommet must be slit at the center line of the hole on the side of the grommet.

Step #9 Slit grommets for express/balloon/ring cut cables as shown below.

Step #8 Select the proper grommet size.

A

B

For Flat Drop Cables or Round Cable diameters .125" to .250" (3.2 -6.4 mm)

For Round Cable diameters .250" to .370" (6.4 -9.4 mm)

For Sumitomo PureFitTM 36 ct. Flat Buffer Tube Cable:

Head of hose clamp must be positioned on flat side of cable.

Align retention clip with cable sheath opening.

C

For Sumitomo PureFitTM 36 ct. Flat Buffer Tube Cable

NOTE: Grommet C is provided pre-slit.

PureFitTM is a registered trademark of Sumitomo Electric Lightwave.

Page 5: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

Step #10 Install slit grommets over express/balloon/ring cut cable.

Step #12 Cut buffer tube at the marked location as shown below.

Step #11 Position grommet 1/16" (2 mm) from the end of the hose clamp retention clip.

1/16" (2 mm)

Buffer Tube After Cut

OFFICE/C.O.

Cut Location

Step #13 Measure buffer tube 10.5" (267 mm) from the sheath opening and remove buffer tube beyond marked location.

10.5" (267 mm)

Installing Expressed Cable in Base

Step #14 Lubricate all four sides of each split grommet with the silicone lubricant.

Lubricate Bottom

LubricateLubricate (Side Not Shown)

5

Grommet C installed on Sumitomo PureFitTM 36 ct. Flat Buffer Tube Cable.

Page 6: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

6

Branch/Drop Cable Preparation

Step #17 Insert branch/drop cables in grommets as shown below.

Step #18 Measure and remove sheath for cut applications (Branch/Drop).

Butt Applications = 50" (1.3 m) In-Line Applications = 42" (1.1 m)

Step #16 Select the proper grommet size.

A

B

For Flat Drop Cables or Round Cable diameters .125" to .250" (3.2 -6.4 mm)

For Round Cable diameters .250" to .370" (6.4 -9.4 mm)

Step #15 Insert the cable strength member behind the tab of the tray support. Insert the back of the hose clamp retention clip in the retention clip slot of the base while inserting the grommet in the grommet pocket.

Retention Clip Slot

For Sumitomo PureFitTM 36 ct. Flat Buffer Tube Cable:

PureFitTM is a registered trademark of Sumitomo Electric Lightwave.

Retention Clip must be inserted into slot next to the outer wall of the base

Pocket

Retention Clip Slot

Page 7: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

7

Step #19 Trim the cable strength members as close to the cable sheath opening as possible.

Step #20 Position the grommet 1/2" (13 mm) from the sheath opening.

Step #21 Measure the buffer tube from the sheath opening as shown below and remove the buffer tube beyond the marked location.

Step #23 Insert the grommet into the grommet pocket of the base.

Installing the Flat Drop Cable in the Base

1/2" (1.3 cm)

Butt Splice Applications = 19” (48.3 cm)In-line Splice Applications = 10.5” (26.7 cm)

Lubricate

Lubricate

Step #22 Lubricate all four sides of the grommet with the silicone lubricant.

Step #24 Insert the cable retention clip into theretention clip pocket and push the clip onto the cable.

PLP Tip: Use a can wrench to push down the cable retention clip into the pocket.

Page 8: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

8

Step #29 Insert the grommet in unused port.

Step #28 Lubricate all four sides of grommet with the silicone lubricant.

Lubricate

LubricateBottom

Lubricate (Side Not Shown)

Step #27 Install the plug(s) in the grommet.

NOTE:Cut plug(s) flush to grommet with side cutters when the plug will be installed in an unused cable port with a tab.

Installing the Grommet in the Unused Cable Port

Step #26 Insert the back of the hose clamp clip in the retention clip slot while inserting the grommet in the grommet pocket.

Retention Clip Slot

Grommet in unused port without tab

Grommet in unused port with tab

Installing the Round Cable in the Base

Step #25 Secure the cable to the hose clamp retention clip with the hose clamp as shown.

Head of hose clamp must be positioned on top of cable.

Align the retention clip with the cable sheath opening.

Page 9: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

9

Routing Buffer Tube(s) From Expressed Cable To Splice Tray

Step #30 Route buffer tube(s) from express/balloon/ ring cut cable to splice tray.

Butt or In-Line Applications

Expressed Cable In

OR

Expressed Cable In

Routing Buffer Tube(s) From Branch/Drop Cable To Splice Tray

Step #31 Route buffer tube(s) from branch/drop cable to splice tray.

Butt Applications

OR

Expressed Cable In

Branch/Drop Cable In

Unused Cable Port

Expressed Cable In

Expressed Cable Out

Expressed Cable Out

Unused Cable Port

Branch/Drop Cable In

Page 10: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

10

Securing Buffer Tubes To Splice Tray

Step #33 Place felt around buffer tubes as shown below.

Step #34 Secure buffer tubes to splice tray with tie wraps as shown below.

Tie WrapsTie WrapsTie Wraps

Step #35 Capture buffer tube under tab on bottom of splice tray as shown.

Capture TabCapture Tab

Fiber Routing In Splice Tray

Step #36 Route incoming fi ber.

1-1/4" (32 mm)

Buffer Tube Opening

Step #32 Route buffer tube(s) from branch/drop cable to splice tray.

In-Line Applications

OR

Expressed Cable In

Unused Cable Port

Expressed Cable In

Branch/Drop Cable In

Branch/Drop Cable In

UnusedCable Port

Expressed Cable Out

Expressed Cable Out

Page 11: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

11

Cover Removal

Step #40 Check the engagement of tabs.

Step #42 Disengage the tabs. Apply light pressure to several tabs until the cover opens.

Tab

Step #41 Insert the screwdriver into the slots.

Slots

Screwdriver

Step #39 Snap the cover on the base.

Before

After

Step #37 Route outgoing fiber.

Step #38 Splice per your accepted company practice.

Cover Installation

Page 12: COYOTE DTC (Drop Termination Closure) Splice … › images › SP3142-1_COY_DTCSpliceTrayKit.pdf• Fiber optic cable opening tools • Flat head screwdriver 4. Bag of Tie Wraps (1)

SAFETY CONSIDERATIONSThis application procedure is not intended to supersede any company construction or safety standards. This procedure is offered only to illustrate safe application for the individual.

FAILURE TO FOLLOW THESE PROCEDURES MAY RESULT IN PERSONAL INJURY OR DEATH.Do not modify this product under any circumstances.

This product is intended for use by trained technicians only. This product should not be used by anyone who is not familiar with, and not trained to use it.

When working in the area of energized lines, extra care should be taken to prevent accidental electrical contact. Be sure to wear proper safety equipment per your company protocol.

For proper performance and personal safety, be sure to select the proper size PREFORMED™ product before application.

PREFORMED products are precision devices. To ensure proper performance, they should be stored in cartons under cover and handled carefully.

P.O. Box 91129, Cleveland, Ohio 44101 • 440.461.5200 • preformed.com • email: [email protected]

Mounting Applications

Step #45 Handholes (COYOTE® GLC base)

Step #44 Pole mounting

Slots for strap mounting.

Step #43 Wall/surface mounting