S7-400H - CPU 414H
Overview
CPU for SIMATIC S7-400H and S7-400F/FH. Can be used in high availability S7-400H systems Can be used with F-runtime license and F-compatible CPU in failsafe S7-400F/FH systems With integrated PROFIBUS DP master interface With 2 slots for sync modules
Application The CPU 414-4H is compatible with the SIMATIC S7-400H and S7-400F/FH. It allows a fault-tolerant S7-400H system to be configured. It can also be used for the failsafe S7-400F/FH automation system in conjunction with an F-runtime license. The integrated PROFIBUS DP interface supports direct connection to the PROFIBUS DP fieldbus as master. Design The CPU 414-4H includes:
High-performance processor: The CPU achieves instruction execution times as low as 60 ns per binary instruction 1.4 MB RAM (700 KB for program, 700 KB for data); load memory for user programs and parameter assignment data of the S7-400H F/FH automation system; high-speed RAM for user program components applicable to execution Memory card: for expansion of the integrated load memory. In addition to the program, the information contained in the load memory includes parameter assignment data for the S7-400H F/FH
S7-400H - CPU 414HCA 01
Seite 1 von 7Price list version 01.10.2007 (Version 25.00)
and therefore requires approximately twice as much space. The result is: Integrated load memory is not adequate for large programs so that a memory card is often required. RAM and FEPROM cards (FEPROM for retentive storage) are available.
Flexible expansion capability: Max. 65K digital, 4K analog I/Os Multipoint interface MPI: The integrated MPI makes it possible to establish a simple network with up to 32 nodes, at a data transmission rate of up to 187.5 kbps. The CPU can establish up to 64 connections to nodes on the communication bus (C-bus) and the MPI. Note: When PROFIBUS DP and MPI interfaces are operated simultaneously, only the following bus connector can be connected to the MPI:
With a socket: 6ES7 972-0BB41-0XA0 Without a socket: 6ES7 972-0BA41-0XA0
Mode selector: Designed as a key-operated switch. Access authorizations can be restricted by means of the removable mode selector. Diagnostics buffer: The last 120 fault and interrupt events are retained in a FIFO buffer for diagnostics purposes Real-time clock: CPU diagnostics messages are date-stamped and time-stamped. PROFIBUS DP interface: The CPU 414-4H with PROFIBUS DP master interface supports a distributed automation configuration with high speed and simple handling. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming). Note: When PROFIBUS DP and MPI interfaces are operated simultaneously, only the following bus connector can be connected to the MPI:
With a socket: 6ES7 972-0BB41-0XA0 Without a socket: 6ES7 972-0BA41-0XA0
Function
Block protection: A password concept also protects the user program from unauthorized access as well as the keyswitch. Integrated HMI services: The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system. Integrated communication functions:
PG/OP communication Expanded communication (simple and high-availability)
Configurable Attributes The STEP 7 "hardware configuration" tool and the installed S7-400H options package are used to configure the features and response of the S7-400H, including the CPUs, for example:
Multipoint interface MPI: Definition of node addresses Startup/cycle behavior Stipulation of the maximum cycle time and communication load
Address allocation: Addressing of I/O modules Retentive area: Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories Protection level: Definition of access authorizations to program and data
S7-400H - CPU 414HCA 01
Seite 2 von 7Price list version 01.10.2007 (Version 25.00)
System diagnostics: Definition of the handling and scope of diagnostics messages Timed interrupts: Setting of periods Configuration of H stations
Safety-related functions The F-runtime license can be used to compile the failsafe F user program and run it on the CPU. A license is required for each S7-400F/FH system. 2 TÜV stickers are included.
Reporting functions Status and fault indicators: LEDs indicate internal and external errors and operating modes such as RUN, STOP, Startup, "Master” mode, redundancy error, test function, etc. Test functions: The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components. Information functions: The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.
Technical specifications (MyMMP) 6ES7 414-4HJ04-0AB0
Supply voltages
Rated value
DC 24 V Yes
Voltages and currents
Feeding of external buffer voltage to CPU 5 to 15 VDC
Current consumption
from backplane bus DC 5 V, max. 2 A
Power loss, typ. 4.5 W
Backup battery
Buffer current, typ. 550 µA
Buffer current, max. 1,530 µA
Memory
Type of storage
RAM
integrated (for program) 700 KByte integrated (for data) 700 KByte expandable No
Load memory
expandable FEPROM Yes; with Memory Card (FLASH) expandable FEPROM, max. 64 MByte integrated RAM, max. 256 KByte expandable RAM Yes; With Memory Card (RAM) expandable RAM, max. 16 MByte
Backup
present Yes
with battery Yes; All data
without battery No
CPU/blocks
DB
Number, max. 4,095; DB 0 reserved
Size, max. 64 KByte
FB
Number, max. 2,048
Size, max. 64 KByte
S7-400H - CPU 414HCA 01
Seite 3 von 7Price list version 01.10.2007 (Version 25.00)
FC
Number, max. 2,048
Size, max. 64 KByte
OB
Size, max. 64 KByte
Nesting depth
per priority class 24
CPU/processing times
for bit operations, min. 0.06 µs
for word operations, min. 0.06 µs
for fixed point arithmetic, min. 0.06 µs
for floating point arithmetic, min. 0.18 µs
Times/counters and their remanence
S7 counter
Number 2,048
Remanence
adjustable Yes lower limit 0 upper limit 2,047 preset From Z 0 to Z 7
Counting range
lower limit 0 upper limit 999
IEC counter
present Yes
Type SFB
S7 times
Number 2,048
Time range
lower limit 10 ms upper limit 9,990 s
IEC timer
present Yes
Type SFB
Data areas and their remanence
Flag
Number, max. 8 KByte
Remanence available Yes; MB 0 to MB 8191
Address area
I/O address area
Inputs 8 KByte
Outputs 8 KByte
of which, distributed
MPI/DPinterface, inputs 2 KByte MPI/DP interface, outputs 2 KByte DP interface, inputs 6 KByte DP interface, outputs 6 KByte
Process image
Inputs, adjustable 8 KByte
Outputs, adjustable 8 KByte
Inputs, preset 1,024 Byte
Outputs, preset 1,024 Byte
Subprocess images
Number of subprocess images, max. 8
Digital channels
Inputs 65,536
Outputs 65,536
Inputs, of which central 65,536
Outputs, of which central 65,536
S7-400H - CPU 414HCA 01
Seite 4 von 7Price list version 01.10.2007 (Version 25.00)
Analog channels Inputs 4,096
Outputs 4,096
Inputs, of which central 4,096
Outputs, of which central 4,096
Hardware config.
Central devices, max. 1
Expansion devices, max. 21
Multicomputing No
IM
Number of connectable IMs (total), max. 6
Number of connectable IM 460s, max. 6
Number of connectable IM 463s, max. 6; IM 463-2
Number of DP masters
integrated 2
via IM 467 0
via CP 10
Mixed mode IM + CP permitted No; IM 467 cannot be used jointly with CP 443-5 Ext.
via interface module 0
Number of operable FMs and CPs (recommended)
FM 32; Limited due to number of slots and number of connections
CP, point-to-point 32; Limited due to number of slots and number of connections
CP, LAN 32; limited due to number of slots and number of connections
Time
Clock
Hardware clock (real-time clock) Yes
buffered and synchronizable Yes
Operating hours counter
Number 8
Clock synchronization
supports Yes
S7 message functions
Number of login stations for message functions, max.
8
Test commissioning functions
Diagnostic buffer
present Yes
Number of entries, max. 3,200
adjustable Yes
preset 120
Communication functions
PG/OP communication Yes
Global data communication
supported No
S7 basic communication
supported No
S7 communication
supported Yes
as server Yes
as client Yes
Useful data per job, max. 64 KByte
S5-compatible communication
supported Yes; via CP and loadable FC
Useful data per job, max. 8 KByte
Standard communication (FMS)
supported Yes; Via CP and loadable FB
S7-400H - CPU 414HCA 01
Seite 5 von 7Price list version 01.10.2007 (Version 25.00)
Number of connections
overall 32
1st interface
Physics RS 485 / PROFIBUS
isolated Yes
Functionality
MPI Yes; Default setting
DP master Yes
DP slave No
MPI
Number of connections 32
Services
PG/OP communication Yes Global data communication No S7 basic communication No S7 communication Yes
Transmission speeds, max. 12 Mbit/s
DP master
Number of connections, max. 32
Services
PG/OP communication Yes S7 basic communication No S7 communication No S7 communication, as client No S7 communication, as server No equidistance support No Activation/deactivation of DP slaves Yes direct data exchange (cross traffic) No
Transmission speeds, max. 12 Mbit/s
Number of DP slaves, max. 32; Number of slots, max. 512
Address area
Inputs, max. 2 KByte Outputs, max. 2 KByte
Useful data per DP slave
Inputs, max. 244 Byte Outputs, max. 244 Byte
2nd interface
Physics RS 485 / PROFIBUS
isolated Yes
Functionality
DP master Yes; Default setting
DP slave No
Point-to-point coupling No
DP master
Number of connections, max. 16
Number of connections (of which reserved), max.
1 for PG, 1 for OP
Services
PG/OP communication Yes S7 basic communication No S7 communication No S7 communication, as client No S7 communication, as server No equidistance support No Activation/deactivation of DP slaves No direct data exchange (cross traffic) No
Transmission speeds, max. 12 Mbit/s
Number of DP slaves, max. 96
Address area
Inputs, max. 8 KByte Outputs, max. 8 KByte
Useful data per DP slave
Inputs, max. 244 Byte
S7-400H - CPU 414HCA 01
Seite 6 von 7Price list version 01.10.2007 (Version 25.00)
Outputs, max. 244 Byte
CPU/programming
Programming language
STEP 7 Yes; V5.0 SP2
LAD Yes
FUP Yes
AWL Yes
SCL Yes
CFC Yes
GRAPH Yes
HiGraph® Yes
User program protection/password protection Yes
Dimensions
Width 50 mm
Height 290 mm
Depth 219 mm
Dimensions
Required slots 2
Weights
Weight, approx. 1,070 g
S7-400H - CPU 414HCA 01
Seite 7 von 7Price list version 01.10.2007 (Version 25.00)